Tender For Supply Of Equipment, Machineries, Set-Ups, Etc. Of Reputed Make (National/ International) For Orissa School Of Mining Engineering, Keonjhar, Odisha. 1 Viscometer Speed Accuracy (RPM): 0.1 In between 6-12Motor Speeds (RPM): Fixed Speeds (1-600) or Variable speed(0.01 -999RPM) Power Requirement: 230 VAC, 50/60 Hz The Viscometer should be supplied with additional below items Spare Parts Kit Calibrating Instrument Calibration Check Kit Rotor Sleeve, Closed Cup 2 2 Lubricity Tester Automatic Speed Control, Pre-set speeds (60, 200, 600, and 1000 RPM), manual speed control, and torque zeroing. Maximum Speed - 1,000 RPM Maximum Torque - 600 inch-pounds Belt-Driven Motor: ½ horsepower, 90 Volt DC, 5.5 Amps Shear rate: 1,000 RPM Maximum Fluid Pressure Range: 5,000 to 10,000 PSI (34,500-69,000 kPa) Power Requirement: 115 / 230 VAC, 50/60 Hz Additional items should be provided with lubricity tester is Heat Cup, Ultrasonic Cleaner, Data Acquisition and other software, Carrying Case 1 3 Dead Weight Fluid loss Apparatus The Dead Weight Hydraulic Assembly should provides source of constant Hydraulic pressure in one compact unit. It consists of a water reservoir, piston and cylinder, dead weight, delivery pressure gauge, two check valves and a bleeder valve. When attached to a standard Filter Press, it should deliver 100 psig pressure to the filter press cell as specified in the American Petroleum Institute, 1 4 API Filter Press with Hydraulic Pressurization API Filter Press Assemblies should consist of a mud reservoir mounted in a frame, a pressure source, filtering medium, Filter press, wall mount and a graduated cylinder for receiving and measuring filtrate. Working pressure is 100 psig and the filtering area is 7.1 in2.The cell body, top cap, and base cap are of stainless steel construction. The items supplied with it should be hydraulic pressure assembly, Case, stainless steel, graduated cylinder 25 graduated cylinder 10 ml, Timer, interval, 30-minute,filter paper etc. 1 5 Filter paper 3.5" filter paper for API filter press 6 Calcimeter Temperature Control: Electronic Variable Temperature Control Maximum Temperature: 1000°F (537° C) Cell Capacity: 50 mL Heating Capacity: 500 Watts Power Requirement: 230 Volt at 1.5 Amp, 50/60 Hz 1 8 Container 30Oz for hamilton beach mixture 30 Oz capacity stainless steel 2 9 Differential sticking tester with one spare Cell Pressurized with a standard hydraulic pressurization Assembly Torque plate with 12.5” radius to simulate casing Standard Test Pressure: 477.5 PSI (3,291 kPa) Working Temperature: Ambient Working Volume: 200 mL 1 10 Digital Stopwatch ISO 9000 certified electronic stopwatch. The timer should be quartz crystal, counts up to 30 minutes in .01 seconds and counts in seconds if over 30 minutes. Each stopwatch should be calibrated against reputed standardisation and a test certificate is supplied with it. 2 11 Emulsion Stability Tester Meter Wave form: Sine, < 5% total harmonic distortion AC Frequency: 340 ± 10 Hz Output Units: Peak Volts Ramp Rate: 150 ± 10 Volts per second, automatic operation Minimum Output Range: 3 - 2,000 Volts (Peak) Trip Current: 61 ± 5 μA Electrode Housing: Material resistant to oil mud components up to 220°F (105°C) Material: Corrosion-resistant metal Diameter: 0.125” ± 0.001” (3.18 ± 0.03 mm) Spacing (gap): 0.061” ± 0.001” (1.55 ± 0.03 mm) at 72°F (22°C) 1 13 Hamilton Beach Mixture The mixture should be 1 spindles. Operating CURRENT 230VOLT/50Hz and 3 speed operating with RPM 10,000 -14,000 & 17,000 14 HTHP Filter Press(175 ml) with Filter press cell clamp for the same along with Hydraulic pressure assembly Maximum Temperature: 350°F (176.7°C) Maximum Pressure (Cell): 2,000 psi (10,343 kPa) Maximum Pressure (Receiver): 750 psi (5.1 MPa) Pressure Source: Hydraulic Test Cell Capacity: 175 mL Receiver Volume: 15 mL Heater: 400 Watt Power Requirement: 230 VAC, 50/60 Hz Along with HTHP filter press 1 no of each spare items and tools below mentioned should be supplied Regulator Repair Kit Spare Parts Kit Carrying Case HTHP Pressure Relief Tool: Safety Clamp for HTHP Fluid Loss Cells: HTHP Cell Cap Puller Test Cell Removal and Carrying Tool 1 15 Filter Paper 2.5" for HTHP filter press 4 16 Hydrometer kit It should include eight (8) hydrometers to measure specific gravity in the range from 0.8 to 2.4 specific gravity (SG) at 60°F.A thermometer with a scale of -30°F to 120°F should be attached to the kit 1 17 Lab Centrifuge The Centrifuge Should Speeds to 3300rpm/1380xGA and six tubes 15mL with Built-in timer 0 to 15 minutes with 30 sec 18 Lab pH meter(Glass Electrode) Built-in electrode standSelectable manual or automatic temperature compensationBuilt-in memory functionHold function, “Ready” indicator, diagnostic messagespH:Range: -2.00 to 16Resolution: 0.01Accuracy: ±0.01Calibration: Up to 5 pointsIon:Range: 0.01 - 2000 ppmResolution: 0.01 ppm / 0.1 ppm / 1 ppmAccuracy: ±0.5% of reading (monovalent) ±1.0% of reading (divalent)Calibration: From 2 to 5 pointsPower:9 VDC, 500 mA,220 VAC, 50 HzInput impedance:>1012Ω Temperature: Selectable manual or automatic from 0 to 100°C Memory: Up to 50 setsRecorder output:±2000 mV (directly proportional to input)Recorder output connector: Mini pin (sub miniature photo plug)Display: Dual display of measurement with temperature and mode annunciators 2 19 Marsh Funnel viscometer With Mug Marsh Funnel-1000cc, Measuring Cup- 1000ml, Digital Stopwatch, Digital Thermometer(50-350F) 4 20 Methylene Blue Test Kit Methylene Blue Test Kit containing all reagents, glassware and hardware required to perform the methylene blue test according the API recommended Practice, all neatly packaged in a rugged Stainless Steel carrying case. 1 21 Mud Balance Density Measurement Ranges: 6.5 - 23.0 lbs/gal 0.79 - 2.72 specific gravity 49 - 172 lbs/ft3 340 - 1190 PSI/1000 ft Includes rugged carrying case 4 22 pH Indicator Strip box of 100,Range 0.00-14,Resolution 1.0 23 Pressurised Mud Balance The density of a fluid sample,Such as cement slurry can be measured in a fixed volume sample under pressure. Density Measurement Ranges: 52 - 164 lb / ft3 6.9 - 21.9 ppg .83 - 2.63 specific gravity 360 - 1130 PSI / 1000 ft 4 24 50 ml Retort kit Temperature Control: Electronic Variable Temperature Control Maximum Temperature: 1000°F (537° C) Cell Capacity: 50 mL Heating Capacity: 500-700 Watts Power 230 Volt at 1.5 Amp, 50/60 Hz 1 25 Sand Content Kit Should contain Sand content Tube,Funnel & Screen Wash Bottle, 500 mL Sieve, 200-Mesh (75 μm), 2.5" Diameter Funnel, Plastic Graduated Tube, Glass, 0 - 20% 4 26 Shearometer Kit The kit should contain Shearometer cup with Scale, Shearometer Tube of 5-gram, Shearometer Tube of 20-gram & Weight set (1 to 200 grams) 1 27 Thermo Cup Electrically heated sample cups should incorporate a precision thermostat for close temperature control. Operating temperatures up to 200°F (93°C) are reached quickly and verified by an included dial thermometer. Meter Wave form: Sine, < 5% total harmonic distortion AC Frequency: 340 ± 10 Hz Output Units: Peak Volts Ramp Rate: 150 ± 10 Volts per second, automatic operation Minimum Output Range: 3 - 2,000 Volts (Peak) Trip Current: 61 ± 5 μA Electrode Housing: Material resistant to oil mud components up to 220°F (105°C) Material: Corrosion-resistant metal Diameter: 0.125” ± 0.001” (3.18 ± 0.03 mm) Spacing (gap): 0.061” ± 0.001” (1.55 ± 0.03 mm) at 72°F (22°C) 2 28 Top Loading Electronic Balance Capacity should be 4100 g with Readability: 0.1 g, Display: LCD w/Backlight & Power usage: 120 VAC-240 VAC, 50/60Hz 1 29 Thermometer Metal dial,5" stem, dual scale 50-500F(0-250C) 3 30 Hot plate magnetic stirrer Electrically hot plate magnetic stirrer with stir bar, operating power supply 230 volt,digital console
|