Stage Rental With A Maximum Of 6.00 M In Front By 4.00 M In Depth, Height From The Floor To The Ground And A Maximum Of 1.40 M, With Trusses Supporting The Floor In Steel Built On “U” Type Beams And Round Tube And “L” Iron In 1020 Steel, 24 M² Wooden Floor, In 18 Mm Naval Maderite With Iron Frame In 50X50 Mm Square Tube. Roof Structure Consisting Of Heavy Line Q30 Aluminum Trusses, Two-Water Model, White Td1000 Canvas Cover With Flame Retardation. 02 Arms In Q30 Aluminum Trusses Measuring 1.00 Meters Each, In The Roof Structure To Support The P.A. Staircase With Handrail, Guard Rails, Closures At The Bottom And Sides In Shadow And Skirt On The Floor., Stage Rental With A Maximum Of 8 , 00 M In Front By 6, Wooden Floor Of 48 M², White Canvas Cover Td1000 With Flame Retardant. 02 Inverted “L” Type Towers Measuring 1.50 M Wide And 7 Meters High In Q30 Aluminum Trusses Connected To The Roof Structure To Support The P.A. Staircase With Handrail, Stage Rental With A Maximum Of 10.00 M In Front 8, Height From Floor To Floor And A Maximum Of 2.00 M, Wooden Floor Of 80 M², Stage Rental With A Maximum Of 12.00 M In Front By 10, Wooden Floor Of 120 M², Two-Water Model Or Geo, White Td1000 Canvas Cover With Flame Retardation. 02 Fly Type Towers Measuring 2.00 M Wide And 8 Meters High In Q30 Aluminum Trusses To Support The P.A. Staircase With Handrail, Stage Rental With A Maximum Of 14.00 M In Front By 12, Wooden Floor Of 168 M² , Professional Stage Rental, Measuring 16 Meters Wide, 14 Meters Deep, 2 Meters From The Floor To The Stage Floor, Mounted On An Iron Structure; Covered In A Box Truss Or Iron Or Steel Structure With A Height Of 10 Meters, Closed In Canvas On The Sides And Bottom, Floor Covered In A Completely Uniform Surface; It Is Extremely Important That The Stage Is Completely Carpeted In Black Or Gray Before The Sound Check. There Is A Side Staircase, Which Can Be Variable. - Structure For Dressing Room In Octanorme, Closed On 04 Sides, Size 04Mx04m. Assembly And Disassembly. With The Floor For Assembly Outside The Stage Being An Extension Thereof. Containing: Sofas / Tables And Plastic Chairs With Covers On The Chairs, Minibar, Large Mirror, Rack With Hangers And 50 Liter Bins With Lids And Garbage Bags. Air Conditioning. Note No. 01.: The Stage Must Present All Signage Required By The Military Fire Department, Including Body Guard And Other Safety Legislation And Fire Extinguishers. Note No. 02.: The Contractor Must Assemble And Disassemble It, According To The Project Developed By The Event And Approved By The Military Fire Department, Without Adding Any Costs To The Provision Of The Service. Note No. 03.: The Contractor Must Provide, Within A Maximum Period Of 24 (Twenty-Four) Hours, The Stage Art, Without Adding Any Charges For The Provision Of The Service. Grounding In Accordance With Technical Standards, With Electronic Speed Regulator, Electrical Launch Cables Compatible With The Needs..., Orbital Model That Must Comply With The Following Minimum Characteristics: A) Structure: Tubular Lattice Aluminum Of At Least 14 Mm (Fourteen Millimeters) ) B) Coverage: Structural Aluminum Spatial Structure, Covered With Flame Retardant Canvas C) Stage Dimensions: 20M (Twenty Meters) Front By 18M (Eighteen Meters) Back, With 2M (Two Meters) Height From Floor To Ground. D) House Mix Mounted On Trellis Q30 2 Floor Levels O Primei
|