Bids Are Invited For Acquisition Of Hospital Medical Equipment, Air Conditioning, Chairs, Furniture, Screens ... in Brazil
Tender Notice
TenderID
87536149
Tender Brief
Bids Are Invited For Acquisition Of Hospital Medical Equipment, Air Conditioning, Chairs, Furniture, Screens For Structuring And Implementing The Womens Health Clinic - Clisam.
Dynapack Plus Urodynamics, With Emg And Infusion Pump Set For Urodynamics, Consists Of: 01 Polygraph Usb Interface In Cabinet With Capacity For Up To 16 Data Acquisition Channels. 01 Chair For Uroflowmetry In Reinforced Aluminum, 01 Load Cell For Uroflowmetry With Protection Overload;02 Graduated Urine Collectors From 0 To 1000 Ml;01 Active Membrane Type Pressure Collector 100 Kpas, Automatic Scales Of - 50A + 350 Cm H2o, Abdominal;01 Active Membrane Type Pressure Collector 100 Kpas, Vesical;10 Extenders For 1.20M Pressure Collectors; 10 Rectal Balloon Probes, 01 Amplifier Software And System That Controls The Infused Volume;10 Silicone Equipment For Infusion Pump;01 Rack To Accommodate The Equipment And It;01 Sets Of Communication And Power Cables;01 New Self-Explanatory Urocommander Data Acquisition Software For Urodynamics, And Reporting Software, Both In Windows Environment, 01 Ibm/Pc Type Computer With Similar Processor And/Or Core I3, 4 Gb Ram Memory, Minimum Screen Of 14” Or Higher With 1366 X 768 Resolution Option, Free Usb Port, Jet Printer Of Color Ink, Windows 10 And Line Filter., Cardiotocograph Fetal Monitor With Printerthis Fetal Monitor Captures And Monitors The Fetal Heart, Fetal Movement, And Uterine Contraction In Patients During Pregnancyinternal Battery With An Average Duration Of 4 Hours With The Monitor On Continuous Use.The Fetal Monitor Is Designed With High-Tech Materials, User Interface With Modern Design And Easy Interaction And 7” Inch Touch Screen.Internal Memory For Storing 720 Minutes Of Exam Monitoring.Fetal Movement Marker ( Fm), Automatic And Manual.Adjustable Toco And Fhr Monitoring Alarms For Bradycardia And Tachycardia.Handle For Transporting The Fetal Monitor.Power Supply With Similar Full-Range System: 100V – 240V +/- 10% 50-60 Hz, Power 70Va / 35W;Transducer Protection Degree: Ipx1 (Drip-Proof);Internal Li-Ion Battery: 7.4V X 2.2 Ah (Rohs Certification); Time To Fully Charge The Battery: 6 Hours With The Monitor In Operation; Average Battery Life: No Less Than 4 Hours With Equipment In Continuous Use; Battery Charger: Internal; Internal High Definition Thermal Printer With Three Printing Speeds: 1, 2 And 3 Centimeters/Minute; On Average, 24 Exams Of 30 Minutes Each Can Be Printed; Printer Paper Lack Alarm;Short-Term Variation (Stv) - Short-Term Variation Examines Fetal Heart Rate Variability From Beat To Beat And Cannot Be Interpreted By Observers Visual Analysis. This Parameter Is Only Available With Computerized Ctg.Printing Paper: 112 (Fhr): 30 ~ 240 Bpm +/- 1%; Transducer With 9 Crystals To Give Greater Sensitivity Of Use;Adjustable Alarm (Fhr): 90 ~ 190 Bpm +/- 1% (Bradycardia/Tachycardia);Toco Monitoring: 0 ~ 100%; Stump Alarm: 0 ~ 100%; Marker, Adult Caster Pressure Device Caster Model Pressure Device For Hospital And Clinical Environments That Can Also Be Adaptable To The Table Or Wall. Aneroid Manometer, B
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 87536149
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.