Cardiac Support Devices – Supply Of Electrophysiology Devices. Quadripolar And Decapolar Diagnostic Electrocatheters For Fixed Curve Electrophysiological Studies With Relative Connection Cables. Diam. 5, 6 Fr Minimum Length 115 Cm. Various Curvatures (Josephson, Cournard, Damato).,Quadripolar And Decapolar Adjustable Diagnostic Electrocatheters, With Relative Connection Cables Minimum Diameter 6 Fr Minimum Length 100 Cm. Various Curvatures And Interelectrode Spacing,Adjustable, Unidirectional Decapolar Diagnostic Electrocatheters With Related Connection Cables Various Curvatures And Interelectrode Spacing, Compatible With The Electroanatomic Reconstruction System,Multipolar Lead For High-Density Mapping, Active Curve, Equipped With At Least 16 Electrodes, Compatible And Viewable With An Electroanatomical Reconstruction System. With Relative Connection Cables,Scaling Electrocatheter, Radiofrequency With 4 Mm And/Or 8 Mm Tip, Active Curve, With Presence Of Magnetic Sensor At The Tip, Compatible With Electroanatomical Reconstruction Systems. With Relative Connection Cables And Rf Return Plates,Radiofrequency Scaling Lead With 3.5Mm Or 4Mm Or 4.5Mm Cooled Tip With Force Sensor, Multiple Holes Compatible With Electromagnetic Reconstruction System. With Relative Connection Cables,Multi-Electrode Ultra-High Density Mapping Lead With Magnetic Sensor Compatible With Electromagnetic Cardiac Chamber Mapping System,Bidirectional Steerable Introducers For The Positioning Of Leads For Access To The Peripheral Vascular System Via The Transseptal Route.,Steerable Balloon Catheters For Cryoablation For Pulmonary Veins, Including Connection Cables, Deflectable Introducer And Circular Catheter For Pulmonary Vein Mapping.N.B. We Require 1 Cryoablation System On Free Loan For Use,External Patch System With The Possibility Of Electroanatomical Navigation As An Electrical And/Or Magnetic System,External Reference Patch System To Be Applied To The Patient For Compatibility With The Electrical Mapping And Ablation System,Esophageal Temperature Monitoring System In 7F Polyurethane, 7 Poles And Possibility Of Electrocardiographic Measurement And Stimulation On All Electrodes. Detection And Connection With Mapping Systems.,Guide To Safely Crossing The Atrial Septum. Specific Guide In Nitinol 0.014, For Crossing The Interatrial Septum, Compatible With Transseptal Introducer Systems, With Radiopaque Tip, Sterile, Disposable.,Multielectrode Ablation Catheters With Electroporesis Technology For Isolation Of Pulmonary Veins In The Treatment Of Atrial Fibrillation. Including Connection Cables And Deflectable Introducer. N.B. Electroporation Energy Generator System On Loan For Use Is Required.,Kit For Transseptal Puncture With Radiofrequency Guidance. N.B. Radio Frequency Generator On Loan For Use Is Required.,Occluding Balloon Catheter For Vena Cava, Nominal Balloon Length 80 Mm,Kit For Vascular Access Dedicated To Occluding Balloon. Occluding Balloon Access And Introduction Kit Consisting Of 0.035 Super-Stiff J-Type Guide, 6F And 12F Introducers, 60 Ml Inflation Syringe,Self-Locking Stylet Expandable For Its Entire Useful Length For Extracting Electrocatheters
|