Special Repair To Bldg No T-05 (Or Line) At Tech Area Of Unit Engrs Under Garrison Engineer Guwahati-- 1 B/R PORTION 2 Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc complete all as specified and as directed. 3 Taking down roof trusses, coupled rafters ortrussed beams clear span above 4 m to 8 m etc complete all as specified and as directed. 4 Dismantling posts or struts (wood, steel or R.C.C.) embeded in concrete, brickwork, masonry etc any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed. 5 Dismantling timber scantlings unframed in fillets, rails, posts, rafters, purlins etc. under 40 sqcm in section, framed work complete all as specified and as directed. 6 Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets and scantling complete all as directed. 7 Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and as directed. 8 Demolition of brick work/ block masonry or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material complete all as specified directed. 9 Materials and labour for Brick work with sub class 'B' bricks straight or curved on plan exc 6.00 m mean radius built in CM 1:6 complete as specified and directed. 10 Material & labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. 11 Material & labour for 15mm thick rendering with cement mortar (1:4)on fair faces of brick work in two layers (10mm& 5mm) seperately mixed with water proofing compound in top layer as per manufacturer's instructions and finishing the surface even and fair without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid seperately under appropiate item. 12 Supply only liquid water proofing compound complete allas specified and as directed. Note :- (i) Dose of WPC as per manufacturer instructions (ii) Contractor should submit purchase voucher before release of payment. 13 Material & labour for rendering 10 mm thick onfaces of brick work or concrete surface in CM (1:6), finished even and smooth without using extra cementcomplete all as specified and directed. 14 M&L preparation of new plastered surfaces and applying two coats of water based acrylic emulsion distemper of approved shade/tint over a coat of primer over & including a coat of 3mm thick wall care putty on walls all as specified & as directed. 15 M & L preparation of new surfaces of wall, finishing walls with Acrylic Smooth exterior paint of approved shade with two coat @ 1.67 ltr/10 sqm over and including priming coat of exterior primer @ 2.20 kg/10 sqm with and including 1.5mm thick wall care putty complete all as specified and as directed. 16 S&F Mild steel framed workwith 10/12mm square bar and MS Flat 25x6 mm such as grills,gratings,etc.with ends of bars shouldered and/or riveted,or forged into spikes,framed guard bars, barred iron doors,ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. 17 Supply and fixing Prepainted galvalume aluminium zink coating GI based profile steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. 18 Supply and fixing Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed. 19 Supply and fixing mild steel work in tubular trusses, purlins, rafter, posts including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 including notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts including rivets or nuts and bolts, providing and fixing cleats, fish plates, gusset plates etc and also for wedging, plumbing, turning up & fixing complete all as specified and as directed. 20 Material & labour Rolled mild steel plates (plain or chequered), channels, square cut or notched (ordinary or counter sunk) forming holes, with riveted, bolted or welded attachment etc, conforming to Fe-290 Gde E-165complete all as specified and as directed. 21 S&F Mild steel screw bolts (machine made) with hexagonal heads at one end and screws other end to be fitted with washes and one hexagonal nut, exc 5cm and n.exc 10cm long and dia of neck 11 to 15 mm as specified and as directed. 22 M&L preparation of new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete as specified and as directed. 23 M&L preparation of new iron and steel surfaces of any description, n exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete as specified and as directed. 24 Taking down chowkhat or frames with shutter (without taking off shutters from the frame) n.exc 1.5 Sqm each complete as specified and as directed. 25 Taking down chowkhat or frames with shutter (without taking off shutters from the frame) exc 1.5 Sqm but n.exc 4 Sqm each complete as specified and as directed. 26 S&F Pressed steel frames of size 125mm x 60mm thick with one or more rebated including necessary fixing lugs, hinges, lock strike plate, etc including filling concrete in hollow portion etc complete as specified and as directed. 27 S&F Flush shutters, 30mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides complete as specified and as directed. 28 M & L 35mm thick 1st class HW Glazed and skeleton shutters, open rebated and prepare to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete as specified and as directed. 29 S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of apreture 1.40 mm & fixed with stainless steel wire staples fixed complete as specified and as directed. 30 S&F 150mm long, Aluminium anodised barrel tower bolts, of extruded section complete as specified and as directed. 31 M&L 300mm long, Aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast, cast or extruded section and fixing bolts and sliding bolts complete as specified and as directed. 32 S&F 100mm size Butt hinges, medium weight, col;d rollded mild steel complete as specified and as directed. 33 S&F 150mm extruded aluminium alloy handles, D- type, with base plate anodised complete as specified and as directed. 34 S&F 300mm mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete, fixed complete complete as specified and as directed. 35 M&L for preparation of new wooden surfaces of any description,over 10cm in width or girth, not otherwise described,and applying two coats of synthetic enamel paint (1st quality) over primingcoat of pinkprimercomplete as specified and as directed. 36 S&F Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows,ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. Note:- (i) Labour charges for fixing of glass/wire guage/aluminum grills is inclusive in the unit rate quoted. Glass/Wire Guage/aluminum grills shall be measured and paidseperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed 37 Supply and fixing 4mm thick Sheet glass frosted, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete as specified and as directed. 38 M&L RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in beam & lintel bend etc like complete as specified and as directed. 39 Formworkto sides of beams, lintel bend rough finished surfce of concrete, supported on RCC pillars, or brick work also splays between floor's and beams etc complete as specified and as directed. 40 M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete as specified and as directed. 41 All as per serial item No.1.39 as abovebut 5 mm dia and over upto and including 10mm dia as in stirrups, spacers and binders. 42 S & F for Anodised aluminium snap grid frame work of size 605 x 605mm for false ceiling complete all as specified and as directed. 43 M & L for 6 mm thick, Non asbestos fibre cement building boards fixed in ceiling or laid/ inserted to timber/GI/Aluminium frame work with screws, etc complete as specified and as directed. 44 Demolition of cementconcrete (Un reinforced)in ground floor n.exc. 15cm thickness (Un re-inforced) below or above GL complete all as specified and asdirected. 45 M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and asdirected. 46 M&L for Hardcore of broken stone or bolders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick,wateredand rammed to a true surface complete all as specified and asdirected. 47 M&L 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone agg as in sub base & plinth protection, finished even and smooth w/o using extra cement complete all as specified and asdirected. 48 Material & labour Virified Ceramic light shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles exe 0.18Sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including cement screed 15 mm thick (1:6) complete all as specified and as directed. 49 M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over 15mm thick screed bed in CM (1:6) etc complete all as specified and as directed. 50 M&L for providing and injecting chemical emulsion for post constructionalanti termite treatment along with external wallbelow concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes and finished upto derived level in apron complete all as specified and directed 51 M&L for providingpost constructionalanti termite treatment by making hole of 12mm dia to be drilled at 300mm apart at the junction of externaland internal wall with floor and construction /expansion joint , if any, ground flooronly and pouring the emulsion at the rate ofone litre per hole and plugging the same with white or coloured cement to match the existing surfacescomplete all as specified and as directed 52 M&L for providinganti termite treatmentat points of contact of wood work such aschowkats of wooden doors, window,ventilators, loft, wardrobes, etc by chemical emulsion(in oil or kerosin based solution) @ 0.5 ltr/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same etc complete all as specified and as directed. 53 E/M PORTION 54 Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and as directed. 55 Taking down carefully UNSV main switch and DB's including MCBs of of any size make, type and capacity and depositing at site complete all as specified and directed 56 Material & labour for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathedFRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC Concealed conduit,medium grade minimum 20 mm dia ISI marked and conduit accessories fixed on recesses of wall/ceiling/roof and chisselling on wall complete andmaking good the disturbed surfaces of wall / ceiling by cement mortar 1:4 including painting to existing surfaces etc with sunken type pressed steel/welded MS terminal boxes made out of 1.2 mm MS sheet, 3mm thickModular top cover for mounting of modular fittings, switches, sockets outlets, regulators etc and provisining of 1.5 sqmm PVC insulatedunsheathed FRLSH cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following srl item No. 2.04 to 2.09 :- 57 One light/ Ceiling/ exhaust fan point controlled by one one/way switch complete all as specified and as directed. 58 One light point controlled by two2way switches complete all as specified and as directed. 59 One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm size complete all as specified and directed. 60 One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed. 61 One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size complete all as specified and directed. 62 All as per item No. 2.03 above but wiring with 4sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and as directed. 63 Material & labour for sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLSH) ISI marked drawing in and including 20mm dia rigid non metalic PVC concealed and conduit & accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed including taking down old submain wiring of any type, complete all as specified and as directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of PVC Conduit with accessories shall be measured as one length. 64 Material & labour for sub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLSH) ISI marked drawing in and including 20mm dia rigid non metalic PVC concealed conduit & accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed including taking down old submain wiring of any type, complete allas specified and as directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of concealed conduit with accessories shall be measured as one length. 65 Supply and fixing as in repair LED Tubelight lights fitting 1x20W, 220V, AC decorative box type with CRCA body precotaed white & pre wired fordriver, holder connecting up with LED down rodthree core flexible copper conductor cable of suitable size from ceiling rose including 1x20 w LED tube Rodcomplete allas specified and as directed. 66 Supply and fixing as in repair LED luminaire600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for false ceiling including connecting up with driver three core flexible copper conductor cases or suitable sizecomplete all as specified and as directed. 67 Supply and fixing as in repair 10W LED Bulkhead light,pressure die cast housing LED bulkhead with IP65 Protection and IK09 Impact resistance suitable for surface/wallmounted, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. 68 Material & labour for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting with LED bulb of 10 W complete all as specified and as directed. 69 Material & labour for taking down ceiling fan, cable end, dismantling blades and removing fan and blades to store, Painting of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. andHanging of ceiling fan with connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed. 70 Material & labour for taking down exhaustfan, cable end, dismantling blades and removing fan and blades to storeand Fixing of exhaust fanand connecting up including provision of cable from ceiling rose/connector to fancomplete all as specified and as directed. 71 Supply and fixing Call bell, Ding Dong AC 230 volts, single pole complete all as specified and as directed. 72 Supply and fixing Modular switch one way 5/6 Amp, 1 module, 240 Voltscomplete all as specified and as directed. 73 Supply and fixing Modular switchtwo way 5/6 Amp, 1 module, 240 Voltscomplete all as specified and as directed. 74 Supply and fixing Modular Bell push 6 Amp, 1 module, 240 Voltscomplete all as specified and as directed. 75 Supply and fixing Modular socket2/3 pin, 6 Amps, 2 module240 Voltscomplete all as specified and as directed. 76 Supply and fixing Modular switchone way, 16 Amp, 1 module, 240 Voltscomplete all as specified and as directed. 77 Supply and fixing Modular socket 16A, 6 pin, 3 module 240 voltscomplete all as specified and as directed. 78 Supply and fixing ceiling rose surface bakelite two to three terminal65 x 50 mm three terminal 250/230 volts ISI markedcomplete all as specified and as directed. 79 Supply and fixingfan step regulator, 120W, 2 Module A/C 240 Voltscomplete all as specified and as directed. 80 Supply and fixing in repair factory made board distribution in sheet steel enclosure vertical double door with 200 Amps ratedbus bar, TPN, 4 ways, 240 Volts suitable for housing MCBsas incomer and SP MCBsas outgoing complete all as specified and as directed. 81 Supply and fixing in repair factory made board distribution in sheet steel enclosure double door glazed with 200 Amps ratedbus bar, SPN, 8 ways, 240 Volts suitable for housing MCBs.complete all as specified and as as directed. 82 Supply and fixingin repair MCB, TPN, 415 volts, C Curve, 63 Amps, 10 KA,4P complete all as specified and as directed. 83 Supply and fixing in repair MCB, SPN, 240 volts, C Curve, 32 Amps 10 KA complete all as specified and as directed. 84 Supply and fixing in repair MCB,SP,240 volts, 20-32 Amps 10 KA, C Curve, complete all as specified and as directed. 85 Material & labour earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SI Part I all as specified and testing on completion includingprovisionof earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work, PCC pit with RCC cover, char coal, salt, funnel etc complete including taking down old earthing. Note:- Rate quoted by tenderers shall be deemed to include for following provisions-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 m. [ii].PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 15 mm bore light grade 7.5m complete all as specified and as directed. 86 Excavating in trenches. n exc 1.5 m wide and n exc 1.5 m in depth ; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting put complete all as specified and as directed. 87 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cmcomplete all as specified and as directed. 88 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. 89 Supply and fixing as in repair 40mm bore tubes, 'Medium Grade' galvanised with all fitting and fixed complete laid intrenches complete all as specified and as directed. 90 Supply and fixing as in repair 20mm bore tubes, 'Medium Grade' galvanised with all fitting and fixed complete laid intrenches complete all as specified and as directed. 91 Supply and fixing as in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipeand fixed of size 40 mm dia complete all as specified and as directed. 92 Supply and fixing as in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipeand fixed of size 20 mm dia complete all as specified and as directed. 93 Supply and laying dry sand cushioning under floors or in foundations including watering and consolidation complete all as specified and directed. Note :- Punned thickness shall only be measured for payment. 94 Material & labour for brick, common burnt clay building bricks, sub-class ‘A’ designation 75 complete all as specified and as directed. 95 Material & labour for 40 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid in trenches complete all as specified and directed. 96 Supply, laying, jointing including testing of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable 25Sqmm x 4core, heavyduty, with aluminium conductor, 1100 Volt grade,laid in treanchs/ ducts/ along wall / under road etc complete all as specified and directed.
|