Radiodiagnostic Devices – Mobile Digital X-Ray Device With C Arm. Full Motorization Of All C-Arm Movements Yes Detector - Cmos Or Igzo Technology With Csi Scintillator Yes Number Of Detectors 1 Size Of The Active Area Of The Detector At Least 300 X 300 Mm Resolution - Number Of Points: At Least 3000 X 3000 Pixels Pixel Size: At Most 100 Μm Display Resolution At Max. Zoom At Least 3.5 Lp/Mm Resolution - Gray Scale At Least 16 Bit Generator Output Power: At Least 25 Kw - Monobloc Silent Fanless Cooling Of The X-Ray Tube (Active Liquid) Min. 5 Million Hu Kv Range At 1 Kv Steps Minimum: Minimum From 40 Kv To 120 Kv Double Focus: Maximum 0.3 / 0.6 Mm Pulse Range For Pulsed Fluoroscopy Min. 1 - 25 Pulses/S Maximum Current During Pulse Fluoroscopy Min. 1- 250 Ma Maximum Current During Continuous Fluoroscopy Min. 2- 15 Ma Pulse Fluoroscopy And Digital Imaging Technology With Automatic Regulation Of The Radiation Dose Yes Automatic Correction Of The Automatic Exposure When Inserting Metal Objects Into The Scanning Field Yes Automatic Regulation Of Pulses When The X-Ray Tube Is Overheated Without Blocking The Device Yes Dose Parameter With Writing To The Active Image With Automatic Transfer To Pacs -U Yes Laser Targeting Built Into The Detector And On The Generator Yes Vertical Shift - Motorized Min. 400 Mm Depth Of The C-Arm: At Least 650 Mm Orbital Movement Of The C-Arm: At Least 160° Angular Movement Of The C-Arm: Total At Least Min. ±220° Swiveling - Arm Swing +/- 10° Motorized Horizontal Movement Min. 250 Mm Free Distance Detector - Emitter Min. 800 Mm Device Width Max. 800 Mm C-Arm Weight Max. 430 Kg Control Lever And Undercarriage Brakes With Color Differentiation Of Control Elements For Individual Movements And Functions Yes At Least 2-Level Zoom With The Possibility Of Taking Pictures Permanently At The Selected Zoom Level Yes Activation Of Radiation By Hand And Foot Switch Yes Adjustable Shutters To Define The Size Of The Primary Beam Yes Shutter - Motorized Iris And Asymmetric Collimator Yes Aperture - Virtual Apertures For Use Without Radiation Yes Collimator Rotation Min. +/-90° Video Loop Imaging Min. 1 - 8 Frames/S Independent Image For Operating The Device On The C-Arm Control Console Yes Controlling The Device With A Touch Screen Yes Built-In Usb 3.0 Interface With Usb Key Min. 16Gb Memory Capacity: At Least 100,000 Images In Dicom Format Yes Tft Monitor Min. 31 Monitor Viewing Angle Min. 170° Resolution Of Tft Monitors Min. 3840X2160 Pixels Brightness Of Monitor Screens Min. 700 Cd/M2 Omnidirectional Monitor Arm With The Possibility Of Setting Any Lateral Position, Height And Tilt Of The Monitor Yes At Least Dicom Version 3.00, Dicom Worklist With Mpps, Dicom Query, Dicom Storage, Dose Report Yes Integrated Software Components Of The Digital Display Unit: Image Rotation, Filtering Image, Edge Enhancement, Image Inversion Yes Anatomical Programs - Bones, Spine Yes Anatomical Programs For Abdomen, Soft Tissues And Uro Yes Function - Pediatric Work Mode With Reduced Radiation Load Yes Video Output
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 87392822
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.