Bare Copper Cable 35Mm² According To Abnt Nbr 6524 Specifications, Bare Copper Cable 50Mm² According To Abnt Nbr 6524 Specifications, Flexible Cable With Copper Conductor, 0.75 Mm², Anti-Flame, For Voltage Up To 750V, Green, Temperatures: 70°C In Permanent Regime;100°C In Overload Regime;160°C In Short-Circuit Regime. Standards: Abnt Nbr Nm 280, Abnt Nbr Nm 247-3 (Iec 60227-3, Mod., White, Blue, 16/10/2024, Color Black, Color Red, Mod), 1.0 Mm², Flexible Cable With Copper Conductor, Green And Yellow, Rigid Copper Conductor Cable, Black, 60°C In Short-Circuit Regime. Standards: Abnt Nbr Nm 280, In Blue Color, 5 Mm², 02, Blue Color, White Color, 5Mm², Green And Yellow Color, 04, 0Mm², Black, Red, 06Mm², Green-Yellow Color, Hepr 90° Flexible Conductor Cable C 0, 6/1 Kv, Bare Copper, Soft Temper, Class 4 Or Class 5 Stringing, Nbr 13248, 6Mm², White. Temperatures: 90°C In Permanent Regime;130°C In Overload Regime;250°C In Short-Circuit Regime. Standards: Abnt Nbr 7286, Abnt Nbr Nm 280., Flexible Conductor Cable Hepr 90°C 0, Blue. Temperatures: 90°C In Permanent Regime;130°C In Overload Regime;250°C In Short-Circuit Regime. Standards: Abnt Nbr 7286, Abnt Nbr Nm 280, Black. Temperatures: 90°C In Permanent Regime;130°C In Overload Regime;250°C In Short-Circuit Regime. Standards: Abnt Nbr 7286, Red. Temperatures: 90°C In Permanent Regime;130°C In Overload Regime;250°C In Short-Circuit Regime. Standards: Abnt Nbr 7286, Green. Temperatures: 90°C In Permanent Regime;130°C In Overload Regime;250°C In Short-Circuit Regime. Standards: Abnt Nbr 7286, 10Mm², 16Mm², 25Mm², 35Mm², 50Mm², 70Mm², 95Mm², Multiplexed Cable 4X10mm Three-Phase Quadruplex, With Isolated Neutral And Blue Color (That Is, Three Isolated Phases And Isolated Neutral And Blue Color), Cfme Standard Celesc, Multiplexed Cable 4X16mm Three-Phase Quadruplex, Cfme Standard Celesc., Pp Cable, Two Ways, 500V, External Color Black And Internal Two Colors, Blue And Black, 2 X 1, Temperature: 70°C. Standards: Abnt Nbr Nm 247-5 (Iec 60227-5, 2 Brown, 4 X 1, 4 X 2, 4 X 4Mm², 4 X 6Mm², 4 C6a, 3Ka, With Din Rail Fixing, C10a, C16a, C20a, C25a, C32a, C40a, 4, 5Ka, C50a, C63a, C70a, Three-Phase Mini Circuit Breaker White 380V, 10Ka, C90a, C125a, Three-Phase Circuit Breaker Nema 40 A - 380V, Three-Phase Circuit Breaker Nema 50 A - 380V, Three-Phase Circuit Breaker 70A, Nema - 380V, Dps Class I/Ii In Compliance With Iec 61643-11, Dps Class Iii In Compliance With Iec 61643-11, Tubular Terminal 00, 75Mm Gray, Tubular Terminal 01, 0Mm Red, 5Mm Black, Tubular Terminal 02, 5Mm Blue, Tubular Terminal 04, 0Mm Gray, Tubular Terminal 06, 0Mm Yellow, Tubular Terminal 10, Tubular Terminal 10Mm Long Red, Tubular Terminal 16, Tubular Terminal 25, Tubular Terminal 35, Double Tubular Terminal 00, Double Tubular Terminal 01, Double Tubular Terminal 02, Double Tubular Terminal 04, 0Mm Blue, Double Tubular Terminal 06, Double Tubular Terminal 10, Double Tubular Terminal 16, Double Tubular Terminal 25, Terminal Double Tubular 35, Eye Terminal 02, Eye Terminal 04, 0Mm A 06, Eye Terminal 06, 0Mm, 100% Copper, Compression Tinned Copper, Eye Terminal 10, Eye Terminal 16, Eye Terminal 25, Eye Terminal 35, Eye Terminal 50, Terminal Olhal 70, Terminal Olhal
|