Conventional Fixed X-Ray Equipment - Command X-Ray Machine And X-Ray Generator - Command Minimum Power: 50 Kw; Microprocessed Control System; Membrane Panel With Single Touch Keys; Minimum Kv Adjustment Range: 40 To 150Kv - With Steps Of 1Kv And 0.5 Kv; Minimum Ma Scale 20, 50, 100, 200, 400, 500, 630 Ma; Automatic Fine/Coarse Focus Selection; Minimum Exposure Time: 0.001 To 5 Seconds (Or Greater); Range Of Mass At Minimum: 0.1 To 630 Mass; Indication Of Parameters/Functions On The Digital Display Of At Least Kv, Ma And Mas; Electrical Supply – Three-Phase 220V Or 380V (Both) – 60Hz. As Described In The Notice., Diagnostic Ultrasound Equipment Without Transesophageal Application - Portable Ultrasound Device - Portable Digital Ultrasound Device With Doppler And Color Power Doppler In High Image Resolution. Ergonomic Control Panel With Backlit Control Keys And Lcd Touch-Screen Display. Fully Digital Technology, Based On Pc Processor, Windows 10 Operating System Or Higher; And User Interaction Software In Portuguese.Applications:: Vascular And Cardiology (Transthoracic And Transesophageal Echocardiography).Dynamic Range Of At Least 250 Db; Frame Rate Greater Than 1300 Fps In B Mode; 08 Control Levels On The Transverse Gain Curve; Cine Memory (Cineloop) With At Least 2000 Frames; Hard Disk (Hdd) Of At Least 500 Gb, Dedicated For Image Storage, Integrated Into The Equipment; At Least 04 Usb Ports For Transferring Stored Images; Battery With Minimum Autonomy Of 90 Minutes; Maximum Weight 8 Kg With Batteries; Possibility Of Exporting Files In The Following Formats: Dicom, Jpeg, Png, Bmp, Mp4, Avi And Raw Data; According To The Description Of The Notice, Digital Mammography-Operation Console Integrated Into The Radiological Protection Screen Or Equivalent Solution, Acquisition Station, Monitor, Mouse, Keyboard And Control Panel. - Digital Mammograph - Operation Console Integrated Into The Radiation Protection Screen Or Equivalent Solution, Keyboard And Control Panel. Microcontrolled High Frequency Generator, Manual Trigger Built Into The Console, Power Of At Least 4.3 Kw. Digital Selection/Display Of Kv But And Exposure Mode. Kv Range Adjustments From At Least 23 To 35 With 1Kv Steps; Range Of Mas Greater Or Equal To 500. Applicable Exposure Modes For Fine And Coarse Focus, Manual, Automatic (Auto Kv And Mas) And Semi-Automatic (Auto Mas). Automatic Microprocessor Exposure Control, Anode Rotation Speed Of At Least 3,000 Rpm, Tube Anode Braking After Exposure. According To The Description Of The Notice., Magnetic Resonance Imaging 1.5T, 70 Cm , Pediatrics, Orthopedics, Cardiology, Musculoskeletal, Oncology And Angiography. 1.Magneto: 1.1. 1.5 Tesla Superconductive; With Active Shielding, Protection Against External Interference; 1.2. Active And Passive Shimming; 1.3. Refrigeration System With Cryogenics (Liquid Helium) And Maximum Typical Helium Evaporation Rate Of 0.0L/H (Zero Boil Off System Or Similar) Under Normal Operating Conditions Of The Refrigeration System (Coldhead And Compressor) Without Interruption And Within Supplier Specifications; 1
|