Instruments For Checking Physical Characteristics – Updated Adv Flow Measurement Sensor (Acoustic Doppler Velocimeter) Request For Quotation. The University Of Turku Is Acquiring 9 Adv Flow Measurement Sensors (Acoustic Doppler Velocimeter) To Be Attached To The Uoma Embankment. With Adv, The Flow Conditions In The River Bed Are Measured Over A Long Period Of Time. With This Updated Request For Quotation, Incorrect Information From The Previous Request For Quotation Has Been Corrected. The Adv Flow Measurement Sensor Must Have At Least Two-Dimensional Flow Vector Measurement (Flow Direction And Speed). Adv Must Measure At Least 15 M Cross-Section Of The Bed. The Measuring Cell Of The Cross Section Of The Adv Must Be No More Than 0.25 M In The 0.2-15 M Part Of The Cross Section Of The Bed. The Sensor Must Have A Scalable Change In Cell Size, I.E. In A Bed Narrower Than 15 M The Measuring Cell Scales Smaller Than 0.25 M. The Measuring Depth Of The Adv Must Be Between 0.5-5 M. Sensors Are Designed To Be Attached Vertically, 2-3 Per Cross-Section Of The Bed To Be Measured, So That The Flow Conditions Of The Bed Can Be Examined From Different Depths. The Other More Specific Mandatory Minimum Requirements Of The Adv Sensor To Be Purchased Are Identified Below. The Sensor Must Include Each Individual Requirement. - Automatic Scaling Of The Measuring Cell According To The Width Of The Measured Bed - Adv Raw Data Export To Common File Formats - Sensor Operation With Batteries And/Or Solar Cells. - Data Transfer According To The Lorawan Standard. All Necessary Software Must Be Included In The Offer. If The Software Requires Separate Annual License Costs, These Possible Annual License Prices Must Be Stated Separately In The Offer. These Separate License Costs Should Not Be Included In The Comparison Price And Are Not Used In The Comparison. Any Annual Maintenance Program And Costs Must Also Be Stated Separately In The Offer. Otherwise, The Options Are Stated Below In A Different Section. The Sensors Data Transfer Must Take Place In Accordance With The Lorawan Standard. The Adv Sensor Must Be Able To Measure The Flow Speed And Direction Of The Water In The Bed In Two Dimensions. The Project Has A Very Limited Implementation Period Due To Funding Conditions. Last Delivery Date: 18.12. Otherwise The Deal Will Collapse.
Contact Information
Address
Yliopistonmäki
Contact No.
+358 503839896
Email
kilpailutus@utu.fi
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 86276129
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.