Bids Are Invited For Pre-Qualification Of Assets To Form A Register For Future Acquisitions Of Photovoltaic ... in Brazil
Tender Notice
TenderID
84429546
Tender Brief
Bids Are Invited For Pre-Qualification Of Assets To Form A Register For Future Acquisitions Of Photovoltaic Distributed Generation System And Components, According To Items Listed In The “Basic Project” Contained In Annex I
Photovoltaic Modules (Boards): Boards With A Minimum Warranty Against Manufacturing Defects Of 12 Years And A Minimum Generation Performance Warranty (≥ 84.8%) Of 25 Years; All Modules Must Be Made Of Monocrystalline Silicon, Identical, Of The Same Model And Half Cell Type Manufacturer. Modules Must Have Inmetro Certification; The Minimum Efficiency Of The Modules Will Be 21%; The Minimum Useful Life Of The Modules Is At Least 25 Years; The Manufacturer Of The Modules Must Have A Tier 1 Classification; Output Power ≥ 550 Wp; Note: Specifications For On-Gride Photovoltaic Solar Energy Microgeneration For Belo Jardim – Pe Installed Power Of 1,200.00 Kwp And Annual Preventative Maintenance For 3 Years Including Panel Cleaning. More Information: Monofacial Solar Panel, Nominal Power Minimum 550Wp, Reference Jam72s30-550/Mr Da Ja Solar, Or Technical Equivalent. The Minimum Nominal Power Was Given As A Reference, As It Is Possible To Replace The Equipment Given As A Reference With One Of Higher Power, As Long As The Total Power Of The Installation Is Maintained., Inverters And Microinverters: Inverters With A Minimum Warranty Against Manufacturing Defects Of 10 Years; Inverters Must Be Three-Phase Of The Grid-Tie Type; The Total Power Of The Inverter(S) Is 100 Kw (Micro Power Generation); It Must Be Without A Transformer, Therefore The Voltage Is 220V; The Inverters Must Have Protection Against Island Operation; The Maximum Noise Level Produced By The Inverters Must Be 55 Db (A) At A Distance Of 1M; They Must Have Protection Against: Reverse Polarity Cc, Overvoltage Cc/Ca Type Ii; Output Short Circuit, Earth Fault, As Well As Protection Against Overtemperature. The Inverters Must Have A Dc Switch In Order To Guarantee Safety During Maintenance; Mppt (“Maximum Power Point Tracking” (“Maximum Power Point Tracking”). Degree Of Protection Ip65. We Emphasize That The Contractor Must Present A Twenty-Year Warranty Certificate, Which Must Be Negotiated With The Equipment Supplier., Cables : The Cables That Will Be Installed Between The Photovoltaic Cells And The Direct Current Terminals Of The Photovoltaic Inverter Must Meet The Requirements Established In Nbr 16612/2020. The Cables Must Have A Maximum Cable Voltage Of 1.8 Kv In Direct Current And Be Suitable For Operation; Between -15 °C And 90 °C;Be Made Of Soft-Tempered Tinned Copper And Comply With Nbr Nm 280 In Stringing Class 5;Have Extruded Insulation Made Of Thermosetting Non-Halogenated Compound; Be Resistant To Ultraviolet Rays; Have A Marking On The Cover With At Least The Following Information: Mark Of Origin, Nominal Section Expressed In Mmz, Inscription “Use In Photovoltaic System”, Year Of Manufacture, Standard Numbering; Note: Specifications For Microgeneration Of Photovoltaic Solar Energy On-Gride For Belo Jardim – Pe Installed Power Of 1,200.00 Kwp And Annual Preventive Maintenance For 3 Years Including Panel Cleaning.More Information: Direct Current (Cc) Circuit Cables - Solar Cable, Section 10, 0Mmz, Insulation 0 , 6/1Kv, In Compliance With Norm Nbr 16.612.
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 84429546
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.