Supply And Delivery Of Lattice Steel . Description Of The Work:The Work Shall Consist Of The Supply Of All That Is Required To Fabricate, Supply And Deliver Transmission Line And Substation Lattice Steel Structures Including Hardware, Non-Exhaustive, Bolts, Step Bolts And Washers In Accordance With The Technical Requirements - Standard Material Specifications 30-3M Latest Revision (Supply Of Transmission Structures) And 30-7M Latest Revision (Supply Of Structural Fasteners, Bolts, Nuts And Washers.)The Total Weight Range: 100,001 To 499,999 Lbs May Include Any Of The Following:Item 1 Miscellaneous Steel100,001 - 200,000 Lbs.&Ndash; With Hardwareitem 2 Miscellaneous Steel 200,001 - 300,000 Lbs.- With Hardwareitem 3 Lattice Steel 300,001 - 400,000 Lbsitem 4 Lattice Steel 400,001 - 499,999 Lbsitem 5 Lattice Steel Rush Order (Purchaser&Rsquo;S Option)Item 6 Trial Assembly Steel Structures (Purchaser&Rsquo;S Option)Supply Labour And Service, Trial Assembly Of Galvanized Steel And Hardware In Accordance To The Technical Requirements, Manitoba Hydro Drawings And Standard Material Specification 30-3M Latest Revision And 30-7M Latest Revision.Item 7 On Site Welding (Purchaser&Rsquo;S Option)Pricing The Specialty Hardware-Field Bolts Not Identified In The Sms And/Or Extra Welding On-Site When Required (Labour Rate/Hour And Equipment /Machine Rentalssteel Structures May Include The Following:Guyed Tangent Suspension Towerguyed Light Angle Towerguyed Medium Angle Towerguyed Heavy Angle Towerguyed Anti-Cascading Suspension Towerself-Supporting Tangent Suspension Towerself-Supporting Tangent Anti-Cascading Suspension Towerself-Supporting Light Angle Towerself-Supporting Medium Angle Towerlattice Station Structures (Gantries, Etc.)Self-Supporting Heavy Angle Towerfor More Information, Contact:Tolulope Sabitumanitoba Hydroscm &Ndash; Procurement Operations Departmentfloor #2 - 360 Portage Avenuewinnipeg Mb R3c 0G8email: Tsabitu@Hydro.Mb.Cacompetitive Procurement Strategy:Request For Proposaltrade Agreements:Cfta, Nwptabids Will Be Opened Privatelymandatory Criteria:All Proposals Must Meet All Of The Following Criteria, In Manitoba Hydro&Rsquo;S Determination, In Order To Proceed To The Second Stage Of The Evaluation Process:Details(A)Csa W47.1 Division 1 Or 2 Certified; Or Csa Division 3 With Proof Of Application With Canadian Welding Bureau For Certification To Division 2(B)Proof That Demonstrates Bolts Have A Minimum Average Charpy Impact Strength Of 20 Joules At 20 Deg. C Through Sample Charpy Tests In Accordance With Astm A370 & Astm E23, As Per Mh Sms 30-07M (Clause 7.2(B)).
Contact Information
Contact Person
Tolulope Sabitu
Contact No.
2043603030
Email
TSabitu@hydro.mb.ca
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 83722900
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.