Tender For Electrical, Mechanical, Instrumental And Related Civil Work Of Zonal Reservoir (03 Nos.) And Gis Mapping For 85 Cusec Ganga Jal Project, Greater Noida, 1 BOQ 2 ZONAL RESERVOIR (R17)CIVIL WORK 3 SUB HEAD :- ERARTH WORK 4 CARRIAGE OF MATERIALS (DSR-1.0/2013) 5 By Mechanical Transport including loading, unloading and stacking (DSR-1.1/2013) 6 Earth (10km) (DSR-1.1.2/2013) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areaa (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m diposed earth to be levelled and neatly dressed. (DSR-2.6/2013) 8 All kinds of soil (DSR-2.6.1/2013) 9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5m. (DSR-2.25/2013) 10 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR-2.27/2013) 11 Clearing grass and removal of the rbbish upto a distance of 50m outside the periphery of the area cleared. (DSR-2.32/2013) 12 SUB HEAD-II :- CONCRETE WORKS 13 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR-4.1/2013) 14 1:4:8 (1 Cement :4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm (DSR-4.1.8/2013) 15 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mmnominal size) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (DSR-4.17/2013) 16 SUB HEAD-III :- REINFORCED CEMENT CONCRETE WORK 17 Centering and shuttering including including strutting, propping etc. and removal of form for all heights including forming grooves as and whereever requried as per drawing. (DSR-5.9/2013) 18 Foundations, footings, bases of columns, etc. for mass concrete. (DSR-5.9.1/2013) 19 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR-5.9.2/2013) 20 Suspended floors, roofs, landings, balconies and access platform (DSR-5.9.3/2013) 21 Shelves (Cast in situ) (DSR-5.9.4/2013) 22 Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR-5.9.5/2013) 23 Columns, Pillars, Piers, Abutments, Posts and Struts (DSR-5.9.6/2013) 24 Stairs, (excluding landings) except spiral-staircases (DSR-5.9.7/2013) 25 Edges of slabs and breaks in floors and walls. (DSR-5.9.16/2013) 26 Under 20cms wide (DSR-5.9.16.1/2013) 27 Cornices and mouldings (DSR-5.9.17/2013) 28 Weather shade, chajjas, corbels etc. including edges. (DSR-5.9.19/2013) 29 STEEL REINFORCEMENT 30 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR-5.22/2013) 31 Thermo-Mechanically Treated bars(DSR-5.22.6/2013) (Sail Steel) 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (DSR-5.22A/2013) 33 Thermo-Mechanically Treated bars (DSR-5.22A.6/2013) (Sail Steel) 34 Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections. (DSR-5.30/2013) 35 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. "(Note :-Cement content considered in this item is @ 330 kg/cum."Excess/less cement used as per design mix is payable/recoverable separately). (DSR-5.33/2013) 36 (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). 37 All works upto plinth level (DSR-5.33.1/2013) 38 All works above plinth level upto floor V level (DSR-5.33.2/2013) 39 Extra for providing richer mixes at all floor levels. (DSR-5.34/2013) 40 Note :- Excess/less cement over the specified cement content used is payable/recoverable separately. 41 Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:-Cement content considered inM-30 is @ 340 kg/cum) (DSR-5.34.1/2013) 42 Providing M-40 grade concrete instead of M-25 grade BMC/RMC. (Note :- Cement content considered in M-40 is @ 360 kg/cum) (DSR-5.34.3/2013) 43 SUB HEAD-IV :- BRICK WORK 44 Brick work with non modular fly ash bricks conforming to IS:12894, class designation10 average compressive strength in super structure above plinth level up to floor V level in : (DSR-6.34/2013) 45 Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.34.2/2013) 46 SUB HEAD-VII :- WOOD AND PVC WORK 47 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, window and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR-9.12/2013) 48 SUB HEAD-VIII :- STEEL WORK 49 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part-1 and M.S. top cover of required thickness for rolling shutters. (DSR-10.6/2013) 50 80X1.25 mm M.S. laths with 1.25 mm thick top cover (DSR-10.6.1/2013) 51 Providing and fixing ball bearing for rolling shutters. (DSR-10.7/2013) 52 Extra for providing mechanical device chain and crank operation for operating rolling shutters. (DSR-10.8/2013) 53 Exceeding 10.00 sqm and upto 16.80 sqm in the area. (DSR-10.8.1/2013) 54 Extra for provding grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in-charge (area of grill to be measured). (DSR-10.9/2013) 55 SUB HEAD IX :- FLOORING 56 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR-11.3/2013) 57 40mm thick with 20mm nominal size stone aggregate. (DSR-11.3.1/2013) 58 Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement :3 coarses sand) finished with a floating coat of neat cement (DSR-11.6/2013) 59 18 mm thick (DSR-11.6.1/2013) 60 Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) (DSR-11.26/2013) 61 25mm thick (DSR-11.26.1/2013) 62 Kota stone slabs 20mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polising complete. (DSR-11.27/2013) 63 Extra for pre finished nosing in treads of steps of Kota stone/sand stone slabs. (DSR-11.31/2013) 64 Extra for kota stone/sand stone in treads of steps and risers using single length up to 1.05 metre. (DSR-11.32/2013) 65 Providing and laying vitrified floor tilies in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR-11.41/2013) 66 Size of Tile 600X 600 mm (DSR-11.41.2/2013) 67 Providing and laying vitrified tilies in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR-11.46/2013) 68 Size of Tile 600X 600 mm (DSR-11.46.2/2013) 69 SUB HEAD- X ROOFING 70 Providing gola 75X75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (DSR-12.21/2013) 71 In 75X75 mm deep chase (DSR-12.21.1/2013) 72 Providing and laying roof insulation with 40mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulaton conforming to IS- 12432 Pt. III (density of foam being 40-50 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providng a wearing coursed of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20mm nominal size) in chequeredrough finish, in panels of 2.5m X 2.5m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. (DSR-12.56/2013) 73 ROOFING SUB HEAD TOTAL 74 SUB HEAD-XI :- FINISHING WORK 75 12mm cement plaster of mix : (DSR-13.1/2013) 76 1:6 (1 cement : 6 fine sand) (DSR-13.1.2/2013) 77 6 mm cement plaster of mix : (DSR-13.16/2013) 78 1:3 (1 cement : 3 fine sand) (DSR-13.16.1/2013) 79 18 mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) (DSR-13.11/2013) 80 Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: (DSR-13.24/2013) 81 Is one coats (DSR-13.24.1/2013) 82 Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR-13.80/2013) 83 Colour washing such as green, blue or buff to give an even shade (DSR-13.39/2013) 84 New work (two or more coats) with a base coat of white washing with lime (DSR-13.39.1/2013) 85 Finishing with epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat,preparation of surface, etc. complete. (DSR-13.52/2013) 86 on steel work (DSR-13.52.1/2013) 87 On concrete work (DSR-13.52.2/2013) 88 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour. (DSR-13.81/2013) 89 Two coats (DSR-13.81.2/2013) 90 SUB HEAD-XII:- SANITARY INSTALLATIONS 91 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vetreous china flushing cistrn & C.P. flush bend with fittings & C.I. brackets, 40mm fluh bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved muninipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: (DSR-17.3/2013) 92 W.C. pan with ISI marked white solid plastic seat and lid (DSR-17.3.1/2013) 93 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430X260X350mm and 340X410X265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting an making good the walls and floors wherever required. (DSR-17.4/2013) 94 One urinal basin with 5 litre white PVC automatic flushing cistern (DSR-17.4.1/2013) 95 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. (DSR-17.7/2013) 96 White Vitreous China Wash basin size 630X450mm with a pair of 15mm C.P. brass pillar taps (DSR-17.7.1/2013) 97 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the receptin of pipes and fittings (DSR-17.8/2013) 98 Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete (DSR-17.28/2013) 99 Flexible pipe (DSR-17.28.2/2013) 100 32mm dia (DSR-17.28.2.1/2013) 101 Providing and fixing 600X450 mm beveled edge mirror of superrior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete (DSR-17.31/2013) 102 SUB HEAD-XII:- WATER SUPPLY 103 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (DSR-18.8/2013) 104 Concealed work, including cutting chases and making good the wall etc. 105 20 mm nominal outer dia Pipes (DSR-18.8.2/2013) 106 25 mm nominal outer dia Pipes (DSR-18.8.3/2013) 107 32 mm nominal outer dia Pipes (DSR-18.8.4/2013) 108 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement trenching, refilling & testing of joints complete as per direction of E/I. (DSR-18.9/2013) 109 100 mm nominal inner dia Pipes (DSR-18.9.9/2013) 110 150 mm nominal inner dia Pipes (DSR-18.9.10/2013) 111 Providing and fixing C.P. brass bib cock of approved quality conforming to IS :8931 (DSR-18.49/2013) 112 15mm nominal bore (DSR-18.49.1/2013) 113 Providing and fixing C.P. brass stop cock (conceale) of standard design and of approved make conforming to IS:8931 (DSR-18.52/2013) 114 15mm nominal bore (DSR-18.52.1/2013) 115 SUB HEAD - XIV - DRAINAGE 116 Making soak pit 2.5 m diameter 3.0 metre deep with 45X45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100mm diameter, 1.8m long complete as per standard design (DSR-19.32/2013) 117 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.32.1/2013) 118 Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. (DSR-19.7/2013) 119 Inside size 90X80 cm and 45 cm deep including C.I. cover with frame (light duty) 455X610mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg.) (DSR-19.7.1/2013) 120 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.7.1.1/2013) 121 Extra for depth for manholes: (DSR-19.8/2013) 122 Size 90X80 cm (DSR-19.8.1/2013) 123 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.8.1.1/2013) 124 SUB HEAD -XV : - ALUMINIUM WORK 125 Providing and fixing aluminium work for door, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and joined mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/stainless steel screw, all complete as per architectural drawings and the directions of Engineer-in-charge (Glazing and paneling to be paid for separately) (DSR-21.1/2013) 126 For fixed portion (DSR-21.1.1/2013) 127 Powder coated Aluminum (minimum thickness of powder coating 50 micron) (DSR-21.1.1.2/2013) 128 For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required (fittings shall be paid for separately) (DSR-21.1.2/2013) 129 Powder coated Aluminum (minimum thickness of powder coating 50 micron)(DSR-21.1.2.2/2013) 130 Providing and fixing glazing in luminium door, windows, ventilator, shutters and partitions etc. with PVC/neoprene gasket etc. complete as per the architectural drawings an the directions of the E/I (Cost of aluminium snap beading shall be paid in basic item) (DSR-21.3/2013) 131 With float glass panes of 4.0mm thickness (DSR-21.3.1/2013) 132 With float glass panes of 5.50mm thickness (DSR-21.3.2/2013) 133 Filling the gap in between aluminuim frame & adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of E/I complete (DSR-21.8/2013) 134 Upto 5mm depth and 5mm width (DSR-21.8.1/2013) 135 SUB HEAD -XVI-WATER PROOFING WORK 136 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water profing compound conforming to IS. 2645 and approved by E/I over the RCC slab inclding adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admided with watr proofing compound conforming to IS 2645 and approved by E/I over 20mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) 137 admixed with water proofing compound conforming to IS : 2645 and approved by E/I to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) after two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by E/I finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by E/I including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300X300 mm square 3mm deep) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curring and for final test. All above operations to be done in order and as directed and specified by the E/I. (DSR-22.7/2013) 138 With average thickness of 120mm and minimum thickness at Khurra as 65mm (DSR-22.7.1/2013) 139 Providing and laying integral cement based treatment for waterproofing on horizontal surface at all depth below ground level for under ground structures as directed by E/I and consisting of : i) Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement 3 coarse sand) mixed with water proofing compound confirming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately) Joints saled and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (DSR-22.1/2013) 140 Using rough kota stone (DSR-22.1.1/2013) 141 Providing and laying integral cement based treatment for waterproofing on the vertical surface by fixing specified stone slab 22mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gap with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement 3 coarse sand) 20mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all level and as direction by E/I. (DSR-22.2/2013) 142 Using rough kota stone (DSR-22.2.1/2013) 143 SUBMERSIBLE PUMP WITH MOTOR 144 Supply, Erection, testing and commissioning of Submersible pump with CI casing,CF8 M impeller , SS 410 shaft, CI casing wearing ring & bearing bush, TC/ SIC mechanical seal, SS strainer etc suitable for3phase,415V,50Hz,ACsupply,submersible motor having TEFC enclosure with class H/F insulationasperspecsandIP68protection.The pump shall be operatedat suitable rpm as per data sheet.Thescopeincludesallrequiredaccessories viz. automaticcouplingdevice,G.Iguidepipe,chain with shakle, flat/ round submersible cable upto starterpanelthroughsuitablesizeG.I.pipewith necessary electrical connection with the starter panel and as per specifications 145 Capacity: 550 M³/hrHead : 42 mtrs.Motor Rating: 110 KW 146 VALVES 147 MOTOR OPERATED SLUICE VALVE 148 Supply,installation,testingandcommissioningof motor operated double flanged, C.I. Sluice Valve 149 Size : 400mm NB forPump Discharge Line 150 Size : 500mm NB forHeader 151 Size : 500mm NB for OHT 152 CHECK VALVE 153 Cast iron double flanged Single Door Swing CheckValve 154 Size : 400mm NB forPump Discharge Line 155 KINETIC AIR VALVE 156 Supply,Installation,testing&commissioningofC.I. doubleactingkineticAirValvewithisolationsluicevalve. 157 Size : 100mm NB 158 MANIFOLD PIPE & PIPE SPECIALS 159 Supply, Fabrication, laying, testing and commissioningof M.S.pipe&specialswith necessary supports & anchoring and including nuts,bolts and hardware 160 Size : 400mm NB forPump Discharge Line 161 Size : 500mm NB forHeader 162 Supply, Fabrication, Fitting, testing and commissioning ofMetallic Expansion Joint with necessary supports & anchoring and including nuts,bolts and hardware 163 Size : 400mm NB forPump Discharge Line 164 Supply, Fabrication, laying, testing and commissioning of pipe fittings and specials includingNuts, bolts and hardware 165 DEWATERINGPUMP 166 Supply, installation,testing&commissioningofnon clog submersible dewateringpump to remove sand, silt,clay,sand,pebbles,smallrock,algae,shells, plankton,etc.(withspecificgravityofupto1.1) having CI casing, CF8 M impeller , SS 410 shaft, CI casingwearingring&bearingbush,suitablefor3 phase, 415 V, 50 Hz, AC supply, submersible motor having TEFC enclosure with class H/F insulation as perspecsandIP68protection.Thepumpshallbe operatedatsuitablerpmasperdatasheetwithall required accessories. 167 Capacity: 50 mtr3/hr. 168 Head : 10 mtrs. 169 Motor Rating: 3.7 KW 170 E.O.T. CRANE WITH HOIST 171 Supply,erection, testing and commissioning offully electrically operated hoist, geared trolley, gantry girder,brake,safetydevice,lockingarrangement, limit switch, pendant push button, starter panel, cables,and other required accessories. 172 Capacity : 5.0 Ton. For Pump room 173 Span : 10 mtrs. 174 Lift :10.00 mtrs. (min) 175 Supply,erection, testing and commissioning offully electrically operated hoist, geared trolley, gantry girder,brake,safetydevice,lockingarrangement, limit switch, pendant push button, starter panel, cables,and other required accessories. 176 Capacity : 2.0 Ton. 177 Lift :5.00 mtrs. (min) 178 CHLORINATION PLANT 179 Supply, installation, testing & commissioning of vacuum control floor mounted gas chlorinator system including necessary fittings, clamp, copper pipe, ferule filter & control valve with injector with required booster pump, set of diffuser entire associated water &chlorinesoulutionpipinguptodiffuseretc, valves,automaticchangeover,Chlorineabsorption system,saftey&testingkit,etc.completeinall respect as per specs & as per following capacity 180 Capacity : 2 x 3 kg/hr 181 Supply,erection, testing and commissioning of single girder electrically operated hoist, geared trolley,brake,safetydevice,lockingarrangement, limit switch, pendant push button, starter panel, cables,and other required accessories. 182 Capacity : 3.0 Ton.for Chlorination plant 183 Span : 5.0 mtrs.(max) 184 Lift :10.00 mtrs. (min) 185 900 kg. Chlorine Tonners duly approvedby dept. ofexplosive 186 ELECTRICAL WORK 187 H.T. INDOOR SWITCH GEAR PANEL 188 Supply,Installation,TestingandCommissioning(SITC)of11 kV, 350 MVA, 400 A, indoor,drawout type Three HT Vaccuum Circuit Breaker Panel (single breaker) withCT and PT ofappropriate rating for meteringand protectionalongwith required Indicating lamps, protection relay and Indicating meters, etc. complete in all respects as per IS, Specification. 189 H.V. CABLES 190 Supply, delivery, laying testing &commissioning of11KV(E), XLPEcablehavingcompactedcircularstarandedaluminium conductor,conductorscreeningofextrudedsemiconducting compound, cross linked polythylane (XLPE), insulation screening oftheextruded semi conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098 (Part-amendments)forfollowingmentionedsizes.Itshouldbe operational at 11 KV, 50 Hz. AC system in ground at a depth of 1200 mm below ground level over a cushion of 75 mm thick sand alround and protected with bricks on sides and 191 top on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directedbytheE/I.Completeinallrespect.Thepriceare inclusive of all earth work such as digging, back filling, supply & spreading of good earth all around the cable, supply & providing cable identification markers. The installation should be complete in all respects and as per requirement of the job. 192 (CCI (Bombay/Nashik), Fort Gloster (Calcutta / Baripara), Asian (Thane/Silvasha),Universal(Satna),Nicco(Calcutta),ICL (Rajpura), Diamond, Havells make SOR-3 193 3CX240 Sqmm. 194 Supply, Delivery,Installation, Testing & Commissioningof 11KV, indoor type cable termination kit of 3 core cable for cable termination at the panel & transformer complete in all respects as required for proper completion of work. (450mm length) SOR-5 (make Raychem/C.C.I./Frontec)d) 3CX240 Sq.mm. 195 DISTRIBUTION TRANSFORMER 196 Supply,delivery, assembly, installation,testingand commissioning of indoor type distribution transformer. 11/0.433 KV, 3 Phase, Double wound winding. Voltage ratio 11000/433-250Volts,vectorgroupDyn11.Aircooledwithmanually operated +5% and +10% off load Tap changer and complete with standardfitting&accessoriesasgiveninthespecificationand also confirming to ISS : 2026 with firsh filling of the oil complete as required. (This includes oil testing for dielectric strength, flask over test and filtration of transformer oil to be conducted in the event of unsatisfactory results of oil testing. (Crompton, NGEF, Alstom,BHEL,Voltamp,Diamond,Reychem,Kanoharmake)SOR-13 Copper wound(e) 315 KVA 197 Supply and levelling of transformer yard using gravel, fine sand andotherrequiredfilingmaterial,enmarked fortheswitchyard includingremoving oftrees orboulders ifany etc.Thegeneral level of the yard shall be at a convenient level for movement of man and material and it should match with FGL. 198 Supply and Installation of Chain link fencing around switch yardetc. as per Specification. 199 SITC of 2.5 mtr wide gate with required material as perSpecification. 200 SITC of Medium Voltage Panel Board 201 MEDIUM VOLTAGE PANEL BOARD 202 Panel Board Encloser & Bus-Bar 203 Supplying,Installation,TestingandCommissioningofIndoor floormountedtotallyenclosed, compartmentalized,extendable type PCC / PMCC / MCC Cubicle Panel Board having 36 MVA, 50Abreakingcapacity ofsuitablesizefabricatedfromCRCA steel of 2 mm thickfor frame work, enclosure and doors, 3 mm thickforglandplateswithstiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, withsuitableelectrolyticgradehighconductivityPVCsleeved aluminium(E91-E)busbarsshallbesizedformaximum 0.8 A/mm2 current density, 204 extensibletype, DMC/SMC busbar supports, suitable for 3 phase-neutral 415 V,50 HZ AC supply i/c providingand fixingthefollowingswitchgearsmounted thereon complete with gaskets and interconnections, connections asperspecificationscomplete asrequired.(Theboardshallbe dust&vermin proofwithdegree ofprotection ofIP52asper IS:12063,freestandingtype,mountedonbasechannelofMS Sectionnotlessthan100mmX50mmX5mm),Isolated cubical compartment for fixed capacitors and as per IS, Specification & Single Line Diagram. (Mini.5.5M length X 1M Min.Width X Maximum 2.3M Height with base channel) 205 500rating4StripPVCSleeved Aluminium(E91-E)Bus-bar (AllbusbarsshallbeconsideringMaximum CurrentDensity 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (8 Mtr.) 206 Incoming Section 207 Incomer Breaker for Transformer (Qty.1 Nos.) 208 4PoleMCCB-500A,50kA,withMicroProcessorbased releases & rotary handle etc. - (1 Nos.) 209 3-Phase Digital Type Multifunction Meter (96x96Sqmm.), Accuracy. Class-0.5S (for Active)suitable to measure kVA, kW, kWH, kVAr, kVArH, A,V, P.F. & Frequency and with RS 485 Communication Portformonitoring &operation fromremote / PLC with suitable Software. - (1 Nos.) 210 500/5A, CL 0.5, 15VA for Metering CTs - (3 Nos.) 211 500/5A, CL.0.5 15VA, CTs for APFC relay - (3 Nos.) 212 On/Off/Trip/SpringchargeLEDtypeIndicationLamp, 220VAC 22.5mm. - (4 Nos.) 213 Control HRC fuses with fuse base (6A) - (6 Nos.) 214 R,Y,B Led Indication Lamp, 220VAC 22.5mm, - (3 Nos.) 215 Digital Voltmeter ( 0-500 V) with control fuses. - (1 Nos.) 216 Digital Ammeter ( 0-500 A) with control fuses. - (1 Nos.) 217 Selectro Switch (For Ammeter & Voltmeter) - (2 Nos.) 218 DG Incomer Breaker D.G (Qty.1 No.) 219 4PoleMCCB-400A,50kA,withMicroProcessorbased releases & rotary handle etc. - (1 Nos.) 220 400/5A, CL 0.5, 15VA, Metering CTs - (3 Nos.) 221 On/Off/Trip/SpringchargeLEDtypeIndicationLamp, 220VAC 22.5mm. - (4 Nos.) 222 Control HRC fuses with fuse base (6A) - (3 Nos.) 223 R,Y,B Led Indication Lamp, 220VAC 22.5mm - (3 Nos.) 224 Digital Voltmeter ( 0-500V) with control fuses. - (1 Nos.) 225 Digital Ammeter ( 0-400A) with control fuses. - (1 Nos.) 226 Selectro Switch (For Ammeter & Voltmeter) - (2 Nos.) 227 Transformer No-load losses comp. Fixed Capacitors forTran. (Qty.1 Nos.) 228 32A3PMCB,50kA,withMicroProcessorbasedreleases& rotary handle etc. - (1 Nos.) 229 16 kVAR Capacitor Duty Contactor - (1 Nos.) 230 Timer for Capacitor - (1 Nos.) 231 R,Y,B Led Indication Lamp, 220VAC 22.5mm - (3 Nos.) 232 On LED type Indication Lamp, 220VAC 22.5mm. - (1 Nos.) 233 Control HRC fuses with fuse base (6A) - (6 Nos.) 234 20A MCB for Capacitor - (1 Nos.) 235 8A MCB for Capacitor - (1 Nos.) 236 6A MCB for Capacitor - (1 Nos.) 237 9 kVAR APP. Type Capacitor - (1 Nos.) 238 4 kVAR APP. Type Capacitor - (1 Nos.) 239 3 kVAR APP. Type Capacitor - (1 Nos.) 240 Outgoing Section 241 210A Soft-Starter for 132kW (Suitable for 110kW Moto afterderating)FeederEachComprisingoffollowing:(Qty.2 Sets.) 242 350A TP MCCB, 36 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.) 243 325A Three Pole AC-3 duty line Contactor - (1 Nos.) 244 630ASemiconductor(FA)Bussmannfusetype170M5012& Fuse Holder-170H3004 - (3 Nos.) 245 210ASoft-Starterfor132kW(Suitablefor110kWMotoafter derating) - (1 Nos.) 246 325A Three Pole AC-3 duty By Pass Contactor of Soft Starter - (1 Nos.) 247 350/5A, CL 0.5, Metering CTs - (3 Nos.) 248 On / Off / Trip LED type Indication Lamp, 220VAC 22.5mm. - (3 Nos.) 249 Stat Push Button - (1 Nos.) 250 Stop Push Button - (1 Nos.) 251 Digital Ammeter ( 0-350A) with control fuses. - (1 Nos.) 252 Selectro Switch (Ammeter) - (1 Nos.) 253 Selectro Switch (Auto/Manual, Local/remote) - (2 Nos.) 254 Pump Protection Unit - (1 Nos.) 255 (MPR + SPP) with CBCT - (1 Nos.) 256 2.5A TP MPCB with Thermostate and 2 nos. Cooling fan (CFM- 105) for Starter Enclosure etc. - (1 Lot) 257 APFC Panel feeder (For 55 kVAR APFC Panel) - (Qty. 1 No.) 258 100 A TPN MCCB, 36 kA, with Micro Processor based release & rotary handle etc. - (1 Nos.) 259 On / Off LED type Indication Lamp, 220VAC 22.5mm. - (2 Nos.) 260 63 A (415V) TPN "C" Curve MCB Feeders - (2 Nos.) 261 32 A (415V) TPN "C" Curve MCB Feeders - (10 Nos.) 262 Power Feeders 263 32 TPN MCB Feeders for Incomer - (1 Nos.) 264 On/OffLEDtype Indication Lamp,220VAC22.5mmfor(a) Incommer - (2 Nos.) 265 6A TPN "C" Curve MCB - (6 Nos.) 266 Miscellaneousaccessories 267 Terminals,Jumperwires,Controlwiring,HRCfuselinkwith ControlFuse,Spaceheater,ControlTransformer,Illumination lamp and all other required Panel Miscellaneousaccessories etc.. - (1 Lot) 268 i) Provide monimum 4 Nos. or 20% spare terminals which ever is higher for control cables.ii)ProvideterminalsforTripinterlockforfutureuse.(Spare shall be supplied with short link) - (1 Lot) 269 Note: i) Auto/Manual and Local / Remote selector switches shall beprovidedforallstarterswhichshalloperatethroughPLC whenselectedinAutoMode.Inmanualmodethedriveshall operate through manually through MCC-PB or through LCS-PB. When Local / Remote switch is selected in local mode or remote moderespectively.Potentialfreecontactsshallbeprovidedto monitordrivestatussignals(A/Mswitchstatus,driveOn/Off status and drive trip status) at PLC.ii)Lowlevelswitchfordryrunprotectionpumpsshallbe interlockedatrespectivestartersthroughprovisionofrequired relays and relay based logic for pumps tripping at ICP. 270 APFC PANEL BOARD (55 kVAR - 8 STEP) 271 Panel Board Encloser & Bus-Bar 272 Supplying,Installation,TestingandCommissioningofIndoor floormountedtotallyenclosed, compartmentalizedtypeAPFC CubiclePanelBoardhaving36MVAbreakingcapacity of suitablesizefabricatedfromCRCAsteelof2mmthick for framework,enclosureanddoors,3mmthickforglandplates with stiffeners wherever required, having vibration free structure chemicallytreatedwithseventankprocessbeforepaintingfor surfacetreatmentandpowdercoated,withsuitableelectrolytic grade high conductivity PVC sleeved aluminium (E91-E) busbars shall be sized for maximum0.8 A/mm2 current density, extensible type, DMC/SMC 273 busbar supports, suitable for 3 phase- neutral415V,50HZACsupplyI/cprovidingandfixingthe following switchgears&capacitorsmounted thereoncomplete withgasketsandinterconnections,connectionsasper specifications complete as required. (The APFC Panel board shall be dust & vermin proof with degree of protection of IP 42 as per IS:12063,freestandingtype,mountedonbasechannelofMS Section not less than 100 mm X 50 mm X 5 mm) and as per IS, Specification (Mini.1.2M length X Min. 750M Width X Maximum 2M Height with base channel) - (Area Sqm.) 274 100A rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (AllbusbarsshallbeconsideringMaximum CurrentDensity 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (2 Mtr.) 275 Incoming Section 276 Incomer Breaker for APFC (Qty. 1 No.) 277 100 A 3P+N MCCB, 36 kA, with Micro Processor based release & rotary handle etc. - (1 Nos.) 278 LED type Indication Lamp, 220VAC 22.5mm dia. For On / Off /Trip - (3 Nos.) 279 LED type Indication Lamp, 220VAC 22.5mm For R, Y, B - (3 Nos.) 280 HRCControlfuseswithfusebase(6A)forvoltmeter, Ameter,APFC relay - (9 Nos.) 281 Digital Voltmeter (0-500V) - (1 Nos.) 282 100/5A, CL-1, 15VA, Metering CTs - (3 Nos.) 283 Digital Ammeter (0-100A) - (1 Nos.) 284 Selectro Switch (For Auto / Manual) - (1 Nos.) 285 APFC Relay 286 8-Step Microprocessor Based APFC Relay - (1 Nos.) 287 Outgoing Section 288 15kVAR Capacitors feeders, Qty. 1 No. 289 32A 3P MCB for Capacitor - (1 Nos.) 290 15kVAR Capacitor Duty Contactor - (1 Nos.) 291 Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.) 292 LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.) 293 15kVAR Double layer APP Type Capacitor - (1 Nos.) 294 10kVARCapacitorsfeederseachComprisingoffollowing:(Qty. 2 Set.) 295 32A 3P MCB for Capacitor - (1 Nos.) 296 10kVAR Capacitor Duty Contactor - (1 Nos.) 297 Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.) 298 LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.) 299 10kVAR Double layer APP Type Capacitor - (1 Nos.) 300 5kVARCapacitorsfeederseachComprisingoffollowing:(Qty. 4 Set.) 301 16A 3P MCB for Capacitor - (1 Nos.) 302 5kVAR Capacitor Duty Contactor - (1 Nos.) 303 Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.) 304 LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.) 305 5kVAR Double layer APP. Type Capacitor - (1 Nos.) 306 MiscellaneousAPFC Panel Accessories 307 Terminals,Jumperwires,Controlwiring,HRCfuselinkwith ControlFuse,Spaceheater,ControlTransformer,Illumination lamp and all other required Panel Miscellaneousaccessories etc.. - (1 Lot) 308 Provide monimum 4 Nos. or 20% spare terminals which ever is higher for control cables. - (1 Lot) 309 Note: Auto/Manual selector switches shall be provided for Auto/Manual mode of opearation to operate APFC Panel through APFCRelay whenselected inAutoMode&inmanualy when selected Manual mode. - (1 Lot) 310 LDB / PDB / JB / LCS 311 SITC of Lighting Distribution Board as under:Supplying and fixing of following ways surface/ recess mounting, verticaltype,415volts,TPNMCBdistributionboardofsheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Single door 312 Incoming Section 313 Supplying and fixing following rating, four pole, (three phase and neutral),415volts,residualcurrentcircuitbreaker(RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 314 Outgoing Section 315 Supplying andfixing 5ampsto32ampsrating,240/415volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 316 SITC of Outdoor Lighting Distribution Board as under: Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/recess complete withloose wire box of sheet steel, dust protected,dulypowderpainted,inclusiveof200ampstinned copperbusbar,commonneutrallink,earthbar,dinbarfor mountingMCB’s, terminalconnectorsforall incomingand outgoing circuits, duly prewired with adequate size of FRLS PVC insulatedcopperconductor uptotheterminalconnector/ neutral link, earthing etc. as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way Double door 317 Incoming Section 318 Supplying and fixing following rating, four pole, (three phase and neutral),415volts,residualcurrentcircuitbreaker(RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 319 32A Contactor 320 Time switch. 321 Outgoing Section 322 Supplying andfixing 5ampsto32ampsrating,240/415volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 323 SITC of Power Distribution Board as under:Supplying and fixing following way prewired vertical type TP&N MCBdistribution boardof steel sheet for415volts on surface/ recess complete with loose wire box of sheet steel, dust protected, dulypowderpainted,inclusiveof200ampstinnedcopperbus bar, commonneutrallink, earthbar, din bar formounting MCB’s,terminal connectors for all incoming andoutgoing circuits, duly prewired with adequate size of FRLS PVC insulatedcopperconductor uptotheterminalconnector/ neutral link, earthing etc. as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way Single door 324 Incoming Section 325 Supplying andfixing 5ampsto32ampsrating,240/415volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 326 Outgoing Section 327 Supplying andfixing 5ampsto32ampsrating,240/415volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 328 SITCofstand/wallmountingJunctionBox withProtection Class of IP-65, fault level-25kA with steel structure stand etc. for Terminationof1.1kVSubmersibleFlexibleCopperPower& Control cable with (A) One run 3C x 185 sq.mm A2XFY power cable. 329 SITCofstand/wallmountingJunctionBox withProtection Class of IP-65, fault level-25kA with steel structure stand etc. for Termination of 1.1 kV Submersible Flexible Copper Power and / or Control cable with (A) 5C x 2.5/1.5 sq.mm ywy control cable. 330 SITCofPendanttypeON_OFFpushbuttonsetcompletewith Enclouser,necessarymounting/fixing arrangementonwall/ pipe support etc. to be installed near motors for remote operation, etc. as per IS and specifications 331 MEDIUM VOLTAGE CABLES 332 Supply & laying of aluminum conductor PVC insulated armoured servedsheathedcables1100Voltsgrateatadepthofbelow ground level over a cushion of 75 mm. below ground level over a cushion of 75 mm. thick sand all round and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer– in charge, complete in all respected. The armouring of the cable shallbe properly connected withthe earth conductor by clamps etc. 333 300sq. mm. 3-1/2 core 334 185sq. mm. 3-1/2 core 335 70sq. mm. 3-1/2 core 336 6 sq.mm. 4 core 337 4 sq.mm. 3 core 338 SITCof1.1kV,YWY/PVCinsulated(IS1554)Cuconductor cables as per specification & IS. 339 3C x 2.5 sq. mm. YWY Cable 340 4C x 2.5 sq. mm. YWY Cable 341 5C x 1.5 sq.mm. YWY Cable 342 10C x 1.5 sq.mm. YWY Cable 343 CABLE END TERMINATION AND CONNECTION: 344 Supplyingandmakingendterminationwithbrasscompression glandandaluminiumlugsforfollowingsizeofPVCinsulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV gradeas required. 345 3½ X 300 sq. mm (70mm) 346 3½ X 185 sq. mm (57mm) 347 3½ X 70 sq. mm (38mm) 348 Supply & fixing of brass nickel plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects .The armoured of the cable shall be properly connected with the earth as per direction of Engineer – in charge. 349 6sq.mm. 4 core 350 4sq.mm. 3 core 351 Supply & fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respects as per direction of Engineer – in charge. 352 6sq.mm. 353 4sq.mm. 354 Supplyingandmakingendterminationwithbrasscompression glandandaluminiumlugsforfollowingsizeofPVCinsulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV gradeas required. 355 3C x 2.5 sq. mm. YWY Cable 356 4C x 2.5 sq. mm. YWY Cable 357 5C x 1.5 sq.mm. YWY Cable 358 10C x 1.5 sq.mm. YWY Cable 359 CABLETRAY 360 Supplying and installing following size of perforated pre-paintedM.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceilingwithM.S.suspendersincludingbolts&nuts,painting suspenders etc as required. 361 450 mm width X 62.5 mm depth X 2.0 mm thickness 362 300 mm width X 62.5 mm depth X 2.0 mm thickness 363 150 mm width X 50 mm depth X 1.6 mm thickness 364 EARTHING 365 Earthingwithcopperearthplate600mmX600mmX3mm thickincludingaccessories,andprovidingmasonryenclosure with cover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. 366 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories,andprovidingmasonryenclosurewithcoverplate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 367 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. 368 Supplyingandlaying25mmX5mmG.Istripat0.50metre belowgroundasstripearthelectrode,includingconnection/ terminatingwithG.I.nut,bolt,spring,washeretc.asrequired. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 369 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 370 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation andre-filling as required. 371 50 x 6 GI strips 372 INTERNALWIRING 373 Wiringforlightpoint/fanpoint /exhaust fanpoint /callbell pointwith1.5sq.mmFRLSPVCinsulatedcopperconductor singlecorecablein surface/ recessedmediumclass PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 374 Supply and wiring of submain with four no. 2.5 sq.mm. FR PVC insulated 1100 V grade multistrand single core copper conductor cable in25mm diaheavy duty (2mm thick)PVCconduit with two no. 1.5 sq.mm. FR PVC insulated 1100 V grade multistrand copperconductorasearthcontinuitywiredrawn insidethe conduit. 375 Wiring for Circuit / Submain wiring along with earth wire with the (2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire) sizes of FRLS insulated copper conductor, Single core cable in Surface / recessed medium class PVC Conduit as required. 376 Supplyandfixingof25mmsizesofmediumClassPVC Conduit alongwith accessories in surface/recess including cuttingthewallandmaking good thesame incaseofrecessed conduit as required. 377 Wiring for twincontrol lightpoint with1.5sq.mm FRLSPVC insulated copper conductor single core cable in surface / recessed mediumclassPVCconduit,2waymodularswitch,modular plate,suitableGIboxandearthingthepointwith1.5sq.mm. FRLSPVCinsulatedcopper conductor single core cableetcas required. 378 Supply and fixing of following size / modules, GI Box along with modular base & cover plate for modular switches in recess etc. as required.(For 15/16A and 5A/6A Switch & Socket) 379 (a) 8 Module (125mm x 125mm) 380 (b) 3 Module (100mm x 75mm) 381 Supply and fixing of following Modular Switch / Socket on the modular plate & Switch box including connections but excluding modular plate etc. as required. 382 6 pin 15/16 Amp Socket outlet 383 15/16 Amp Switch 384 3 pin 5/6 Amp Socket outlet 385 5/6 Amp Switch 386 Supplyingandfixing20amps,240volts,SPNindustrialtype, socketoutlet,with2poleandearth,metalenclosedplugtop alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 387 Supplyingandfixing30amps,415volts,TPNindustrialtype, socketoutlet,with4poleandearth,metalenclosedplugtop alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (Pump house & Panel room) 388 Supplying andfixing TPsheet steel enclosure on surface/recess along with 16/25/32amps 415 volts “C” curve TP MCB complete withconnections,testingandcommissioningetc.asrequired. (For Ele. Hoist etc.) 389 INTERNAL LIGHT FIXTURES 390 Supply and fixing of factory wired HPF industrial type fluorescenttubelightfittingwithvitreousenameledreflector suitablefor2X40wfluorescenttubeincludingtubesetc.on surface complete in all respects.Cat AA (seg.) 391 Supplyandfixingoffactorywired,surfacetypemirroroptic fittingsmadeofpreanodizedaluminiumsectionwithP2/P5 louvers suitable for & with 2no.36 w CFL complete in all respect. Cat AA 392 Supply and fixing of factory wired asymmetrical beamed integral floodlightluminaireswithdiecastaluminiumhousing&A1.reflector havingbuiltincontrolgearunitdulyprewiredplate complete with ballast, ignitor ,capacitor for 1*150 w M.H. with lamp complete in all respect.Cat AA 393 Supplyandfixingofindustrialbulkheadfittingwith polycarbonate base guard, prismatic reflector silicon gasket suitable for and with 1X18 w CFL complete in all respect.Cat A 394 380mmsweep1400R.P.Mexhaustfan,capacitortype, having double ball bearing, M.S.blades, mounting frame, forearms, suitable to operate on 230V,50 HZ AC supply conforming to IS: 2312.Fanshallbe painted withepoxy grey colour controlled by one 6 A flush type switch on board and 6A plug point near Ex. fan. 395 1200mmsweepceilingfan,capacitortype,havingdoubleball bearing 450mm down rod, canopies, shackle, rubber bush, blades, electronic speed regulator, suitable to operate on 230V,50Hz AC supply conforming to IS: 374/1979.Fan shall be painted with white colour. 396 EXTERNAL LIGHT FIXTURES 397 Supply and fixing of factory wired asymmetrical beamed integral floodlightluminaireswithdiecastaluminiumhousing&A1.reflector havingbuiltincontrolgearunitdulyprewiredplate complete withballast,ignitor ,capacitor for 1*150W M.H. with lamp complete in all respect.Cat AA 398 Supply &erection of Steel tubularsingle wing pole with30cm around&1/6overalllengthofpolegroutedwithcement concretein1:3:6(1cement:3coarsesand:6stoneballast) including plinthing of pole &15cm around &30 cm above the groundlevel,plasteringofplinthincludingexcavationback fillingetc.Theratesincludesallmaterialslabour&T&P.etc. requiredforpropercompletion ofworkasperdirectionofE/I.SOR-20a) 410 SP-17, 8.5mtr., 92kg. 399 Supplyandfixingoffactorywiredsodiumvapourlampstreet light luminaries single piece cast “Aluminium” body suitable for 70w S.V. lamp including integral control gear, 70w S.V. lamp onG.I. pipe bracket complete in all respects on on pole. 400 Supply and fixing of H.P.M.V. post top lantern, suitable for 80wM.V. lamp complete with control gear pole mounting box and 80 w M.V. lamps etc. complete in all respects.Cat AA (seg.) 401 DIESEL GENERATOR WITH AMF PANEL SET 402 SITCOFDIESELGENERATORWITHENGINE,ALTERNATOR & DG CONTROLLER SET 403 SITCof225KVADGsetorhigherrating(asrequiredtorun completeworkingloadofpumpingstationincludinglighting.)415 V,50 Hz,3 Phase, 4 wire Diesel Generator (Engine, Alternator & DG Controller) Set. Diesel engine shall be complete with necessary controls and safety devices confirming to relevent ISS/BSS with latest amendements. Diesel Engine shall be suitable for continuous operation of generator set duty inclusive offly wheel, aircleaner, radiator.fan withguard,fuel pump,fuel filter,Electronic governor,electrical starting system with starter,12 Vbattery,voltageregulator,instrument panel,Exhaustsilencer, protections against low lubrication oil pressure,high water temperature. 404 Alternatorshallbe415V,3phase,50Hz,4wire,0.8power factor,selfexcited,self regulated,brushless type,drip proof confirmingtoIS:4722withlatestamendments.DGsetshall complylatestemissionnormsofMinistryofEnvironment& Forest(MOEF)byGovernmentofIndia,effectivefromJuly 2014. DG set engine shall be manufactured as per present CPCB norms.DGsetratingshallbeforprimeratingpower(PRP)in accordancewithBS5514/IS/ISO.DGsetshallmeetall statutory/ pollution control regulationrequirementwith all currently applicable statutory norms, regulations and safety codes of the latest applicable Indian Standards. 405 The engine and alternator shall be coupled over a sturdy common base frame. Day fuel tank with necessary fuel to hoses the engine fule and complete in all respect as required. DG set shall be along with acoustic enclosure / canopy and suitable for outdoor mounting. 406 SITC OF AMF PANEL 407 Panel Board Encloser & Bus-Bar 408 Supplying,Installation,TestingandCommissioningofIndoor floormountedtotallyenclosed, compartmentalized,extendable typeAMF Panel Board having36 MVA, 50 kA breaking capacity ofsuitablesizefabricatedfrom CRCAsteel of2mm thickfor frame work, enclosure and doors, 3 mm thick for gland plateswithstiffenerswhereverrequired,havingvibrationfree structure chemicallytreatedwith seventank processbefore paintingforsurfacetreatment andpowdercoated, with electrolytic grade high conductivity PVC sleeved aluminium (E91 409 E)busbars,DMC/SMCbusbarsupports,suitablefor3phase- neutral415V,50HZACsupplyi/cprovidingandfixingthe followingswitchgearsmountedthereoncompletewithgaskets and interconnections, connections as per specifications complete as required. (The board shall be dust & vermin proof with degree ofprotectionofIP52asperIS:12063,freestandingtype, mounted on base channel of MS Section not less than 100 mm X 410 50 mm X 5 mm), Isolated cubical compartmentfor fixed capacitors and as per IS, Specification & Single Line Diagram. (Mini.0.8M lengthX 0.75M Min.WidthX Maximum2.3M Height with base channel) 411 630A rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (AllbusbarsshallbeconsideringMaximum CurrentDensity 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (1.50 Mtr.) 412 DG Incomer Breaker, (Qty. 1 Set) 413 4Pole ACB - 630A, 50 kA, with Micro Processor based releases (Overload, Short Circuit and earth fault protetive release) etc. - (1 Set) 414 3-Phase Digital Type Multifunction Meter (96x96Sqmm.), AccuracyClass-1,suitabletomeasureA,V,P.F.&Frequency and with RS 485 Communication Port for monitoring & operation from remote / PLC with suitable Software. - (1 Nos.) 415 3-Phase Digital Type Trivector / Energy Meter, Accuracy Class- 0.5S(ForActive), suitabletomeasure kVA,kW,kWH,kVAr, kVArH, P.F. & Frequency and with RS 485 Communication Port formonitoring&operationfromremote/PLCwithsuitable Software. - (1 Nos.) 416 630/5A, Core-1 CL 0.5, 15VA for Metering - (3 Nos.) 417 Control HRC fuses with fuse base (6A) - (6 Nos.) 418 Digital Voltmeter (0-500V) with control fuses. - (1 Nos.) 419 Digital Ammeter (0-630A) with control fuses. - (1 Nos.) 420 LED type Indication Lamp, 220VAC 22.5mm for On / Off / Trip/ Spring charge- (4 Nos.) 421 LED Indication Lamp, 220VAC 22.5mm for R,Y,B - (3 Nos.) 422 LED Indication Lamp, 220VAC 22.5mm for Load ON, Controln ON, Breaker ON & OFF - (4 Nos.) 423 Push Button for Engine Start & Stop, Emergency Stop, ACB Trip & Closed, Hooter Accept - (6 Nos.) 424 Selectro Switch for Ammeter, Voltmeter, Control Supply On&Off, Auto-Manual mode, Local-Rermote (PLC) mode. - (5 Nos.) 425 Automatic Mains Failure (AMF) Digital Relay - (1 Nos.) 426 Line Voltage Monitoring digital Relay - (1 Nos.) 427 Fully Automatic Battery Charger - (1 Nos.) 428 Digital type DC Voltmeter (0-50V) - (1 Nos.) 429 Digital type DC Ammeter (0-10A) - (1 Nos.) 430 DC Control HRC fuses with fuse base (6A) - (6 Nos.) 431 DC Selectro Switch (For Battery Charger On&Off) - (1 Nos.) 432 Miscellaneousaccessories 433 Terminals,Jumperwires,Controlwiring,HRCfuselinkwith ControlFuse,MCBs,AuxiliaryRealys,AuxiliaryContactors, Spaceheaters,Controltransformer,Illuminationlampsandall other required Panel Miscellaneousaccessories etc. - (1 Lot.) 434 Provide minimum 4Nos. or 20%spare terminals whichever is higher for control cables. - (1 Lot.) 435 Note:Auto-ManualselectorswitchandLocal-Remote(PLC) selectorswitchshallbeprovidedforeachAMFPanel,when selected in Auto mode, the panel shall operate through AMF relay & in manual mode, the Panel shall operate through manually, in manual mode through local-remote selector switch, in local mode panelshalloperatethroughPanelPush-Buttonandinremote mode, panel shall operate through PLC. 436 SAFETYACCESSORIES 437 Supply and fixing of fire extinguisher, dry chemical type 5.00 kg. Capacity(ISImark)completeswithinitialchargeandwall bracket, along with supply of all materials and labour for proper completion of work. 438 Providing and fixing H.T. danger notice plate of 250mmX200mm, madeofmildsteel,atleast2mmthick,and vitreousenameledwhiteonbothsides,andwithinscriptionin single red colour on front side as required. 439 Providing and fixing M.V. danger notice plate of 200mmX150mm, madeofmildsteel,atleast2mmthick,and vitreousenameledwhiteonbothsides,andwithinscriptionin single red colour on front side as required. 440 Supply and fixing of shock treatment chart(prescribed under I.E. rules) duly framed with glass and supported from back with hard boardorsoftboardwithsupply ofallmaterial labourT&Pfor proper completion of work. 441 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11litrescapacitydulypaintedasperfirebrigadedesign, supported on hanging bracket chained and locked, initially filled withfineriversand,waterasperdirectionsofEngineer-in- charge. 442 Supply and layfing of 1800mmX900mmX12mm thick chequered rubber matting of tested quality. 443 Supply and fixing of20 Wfluorescent lampoperated emergencylightwithmaintenancefreebatteryfor3hoursopeation during mains power failure. 444 First Aid box. 445 11 kV Rubber Hand Gloves 446 STRUCTURE STEEL 447 Supply&InstallationofStructureSteelrequiredforsupport structureofequipments, LCS,cable,cabletray&earthingetc. forsupportonfloor/wall/beam/bracketsetc.including required welding/ cutting/ grinding shall be done to complete the job. 448 INSTRUMENT WORK 449 PRESSURE MEASURMENT SYSTEM 450 Supply, installation, testing & commissioning of 451 Pressuretransmitterwith indicator& all accessories 452 at delivery of each Pump and common header. 453 Range : 0 - 10 kg / sq.cm. 454 PRESSUREGUAGE 455 Supply, installation, testing & commissioning of 456 Bourdanpressureguagehaving150mmdialwith 457 necessaryS.S.cock at delivery line of each Pump. 458 Range : 0 - 10 kg / sq.cm. 459 PRESSURESWITCH 460 Supply, installation, testing & commissioning of 461 Pressure switchat delivery line of each Pump. 462 Range : 0 - 10 kg / sq.cm.(Adjustable type) 463 FLOWMEASURING SYSTEM 464 Supply,installation, testing and commissioning of 465 Electromagnetictype flow meterwith indiactor,transmitter andtotaliserwithallaccessoriesand, 466 hardwares, etc.complete in all respects. 467 Size : 500 for manifold size 500 mm of R17 Header 468 LEVEL MEASURING SYSTEM 469 Supply, installation, testing & commissioning 470 Ultrasonic type Level transmitter with indicator andall 471 requiredaccessories& hardwares, etc. completein 472 all respects. 473 Range : 0 - 6 Mtrs.Supply, installation, testing & commissioning of Float 474 & Board type level indicator with all accessories. 475 Range : 0 - 6 Mtrs.Supply, installation, testing & commissioning of Float 476 typelevelswitch withallaccessoriesforDryrun 477 protection of pumps. Range : 0 - 10 Mtrs. 478 FRC ANALYZERSupply, installation, testing & commissioning of Amperometrictype FreeChlorineAnalyzer complete withtransmitter,sensor,sensorcable,Sensor mountingassembly ,accessories, hardware,consumables, etc. complete in all respects.Measuring Range : 0 - 5 mg/L 479 PLC / SCADA FOR CONTROL ROOM 480 Supply,installation, testing and commissioning of PLC-SCADA system including Instrument control Panel,PCbasedHMIalongwith19"colourLCD Screen, Required programming/ SCADA/Application Software, A3 Size Laser Printer, GSM-GPRS / BroadbandbasedcommunicationforRemoteData Transmission,Min.1kVA UPS (with 30min backup alongwithsuitable rating SMFbatteries &battery chargerand allotheraccessoriesasperstandard), etc.completeinallrespectsandasper specifications. PLC shall have I/O count of32 DI / 16 DO / 8 AI / 0AO. 481 INSTRUMENT CABLES 482 Supply,laying,testingandcommissioningof Instrument Cables including termination & Trays 483 3C X 2.5 sq.mm YWY Power cable 484 1PX 1.5sq.mmCu.Conductor,armoured,overall& individual shieldedSignal cable 485 2C X 1.5 sq.mmCu. Conductor,armoured ,overallshielded Control cable 486 10CX1.5sq.mmCu.Conductor,armoured,overall shielded Control cable 487 INSTRUMENT CABLETRAY 488 Supplyingandinstallingfollowingsizeofperforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors,suspendedfromtheceilingwithM.S. suspenders including bolts & nuts, paintingsuspenders etc as required. 489 100 mm width X 50 mm depth X 1.6 mm thickness 490 200 mm width X 50 mm depth X 1.6 mm thickness 491 CABLE END TERMINATION AND CONNECTION: 492 Supplyingandmakingendterminationwithbrass compression gland and copper lugs for following size ofPVCinsulatedandPVCsheathedcopperconductor cable of 1.1kV gradeas required. 493 POWER CABLE 494 3C x 2.5 sq.mm 495 CONTROL CABLE 496 2C x 1.5 sq.mm 497 10C x 1.5 sq.mm 498 SIGNAL CABLE 499 1P x 1.5 sq.mm. 500 ZONAL RESERVOIR (R18)CIVIL WORK 501 SUB HEAD :- ERARTH WORK 502 CARRIAGE OF MATERIALS (DSR-1.0/2013) 503 By Mechanical Transport including loading, unloading and stacking (DSR-1.1/2013) 504 Earth (10km) (DSR-1.1.2/2013) 505 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areaa (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m diposed earth to be levelled and neatly dressed. (DSR-2.6/2013) 506 All kinds of soil (DSR-2.6.1/2013) 507 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5m. (DSR-2.25/2013) 508 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR-2.27/2013) 509 Clearing grass and removal of the rbbish upto a distance of 50m outside the periphery of the area cleared. (DSR-2.32/2013) 510 SUB HEAD-II :- CONCRETE WORKS 511 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR-4.1/2013) 512 1:4:8 (1 Cement :4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm (DSR-4.1.8/2013) 513 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mmnominal size) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (DSR-4.17/2013) 514 SUB HEAD-III :- REINFORCED CEMENT CONCRETE WORK 515 Centering and shuttering including including strutting, propping etc. and removal of form for all heights including forming grooves as and whereever requried as per drawing. (DSR-5.9/2013) 516 Foundations, footings, bases of columns, etc. for mass concrete. (DSR-5.9.1/2013) 517 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR-5.9.2/2013) 518 Suspended floors, roofs, landings, balconies and access platform (DSR-5.9.3/2013) 519 Shelves (Cast in situ) (DSR-5.9.4/2013) 520 Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR-5.9.5/2013) 521 Columns, Pillars, Piers, Abutments, Posts and Struts (DSR-5.9.6/2013) 522 Stairs, (excluding landings) except spiral-staircases (DSR-5.9.7/2013) 523 Edges of slabs and breaks in floors and walls. (DSR-5.9.16/2013) 524 Under 20cms wide (DSR-5.9.16.1/2013) 525 Cornices and mouldings (DSR-5.9.17/2013) 526 Weather shade, chajjas, corbels etc. including edges. (DSR-5.9.19/2013) 527 STEEL REINFORCEMENT 528 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR-5.22/2013) 529 Thermo-Mechanically Treated bars(DSR-5.22.6/2013) (Sail Steel) 530 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (DSR-5.22A/2013) 531 Thermo-Mechanically Treated bars (DSR-5.22A.6/2013) (Sail Steel) 532 Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections. (DSR-5.30/2013) 533 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. "(Note :-Cement content considered in this item is @ 330 kg/cum."Excess/less cement used as per design mix is payable/recoverable separately). (DSR-5.33/2013) 534 (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). 535 All works upto plinth level (DSR-5.33.1/2013) 536 All works above plinth level upto floor V level (DSR-5.33.2/2013) 537 Extra for providing richer mixes at all floor levels. (DSR-5.34/2013) 538 Note :- Excess/less cement over the specified cement content used is payable/recoverable separately. 539 Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:-Cement content considered inM-30 is @ 340 kg/cum) (DSR-5.34.1/2013) 540 Providing M-40 grade concrete instead of M-25 grade BMC/RMC. (Note :- Cement content considered in M-40 is @ 360 kg/cum) (DSR-5.34.3/2013) 541 SUB HEAD-IV :- BRICK WORK 542 Brick work with non modular fly ash bricks conforming to IS:12894, class designation10 average compressive strength in super structure above plinth level up to floor V level in : (DSR-6.34/2013) 543 Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.34.2/2013) 544 SUB HEAD-VII :- WOOD AND PVC WORK 545 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, window and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR-9.12/2013) 546 SUB HEAD-VIII :- STEEL WORK 547 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part-1 and M.S. top cover of required thickness for rolling shutters. (DSR-10.6/2013) 548 80X1.25 mm M.S. laths with 1.25 mm thick top cover (DSR-10.6.1/2013) 549 Providing and fixing ball bearing for rolling shutters. (DSR-10.7/2013) 550 Extra for providing mechanical device chain and crank operation for operating rolling shutters. (DSR-10.8/2013) 551 Exceeding 10.00 sqm and upto 16.80 sqm in the area. (DSR-10.8.1/2013) 552 Extra for provding grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in-charge (area of grill to be measured). (DSR-10.9/2013) 553 SUB HEAD IX :- FLOORING 554 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR-11.3/2013) 555 40mm thick with 20mm nominal size stone aggregate. (DSR-11.3.1/2013) 556 Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement :3 coarses sand) finished with a floating coat of neat cement (DSR-11.6/2013) 557 18 mm thick (DSR-11.6.1/2013) 558 Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) (DSR-11.26/2013) 559 25mm thick (DSR-11.26.1/2013) 560 Kota stone slabs 20mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polising complete. (DSR-11.27/2013) 561 Extra for pre finished nosing in treads of steps of Kota stone/sand stone slabs. (DSR-11.31/2013) 562 Extra for kota stone/sand stone in treads of steps and risers using single length up to 1.05 metre. (DSR-11.32/2013) 563 Providing and laying vitrified floor tilies in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR-11.41/2013) 564 Size of Tile 600X 600 mm (DSR-11.41.2/2013) 565 Providing and laying vitrified tilies in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR-11.46/2013) 566 Size of Tile 600X 600 mm (DSR-11.46.2/2013) 567 SUB HEAD- X ROOFING 568 Providing gola 75X75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (DSR-12.21/2013) 569 In 75X75 mm deep chase (DSR-12.21.1/2013) 570 Providing and laying roof insulation with 40mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulaton conforming to IS- 12432 Pt. III (density of foam being 40-50 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providng a wearing coursed of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20mm nominal size) in chequeredrough finish, in panels of 2.5m X 2.5m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. (DSR-12.56/2013) 571 ROOFING SUB HEAD TOTAL 572 SUB HEAD-XI :- FINISHING WORK 573 12mm cement plaster of mix : (DSR-13.1/2013) 574 1:6 (1 cement : 6 fine sand) (DSR-13.1.2/2013) 575 6 mm cement plaster of mix : (DSR-13.16/2013) 576 1:3 (1 cement : 3 fine sand) (DSR-13.16.1/2013) 577 18 mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) (DSR-13.11/2013) 578 Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: (DSR-13.24/2013) 579 Is one coats (DSR-13.24.1/2013) 580 Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR-13.80/2013) 581 Colour washing such as green, blue or buff to give an even shade (DSR-13.39/2013) 582 New work (two or more coats) with a base coat of white washing with lime (DSR-13.39.1/2013) 583 Finishing with epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat,preparation of surface, etc. complete. (DSR-13.52/2013) 584 on steel work (DSR-13.52.1/2013) 585 On concrete work (DSR-13.52.2/2013) 586 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour. (DSR-13.81/2013) 587 Two coats (DSR-13.81.2/2013) 588 SUB HEAD-XII:- SANITARY INSTALLATIONS 589 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vetreous china flushing cistrn & C.P. flush bend with fittings & C.I. brackets, 40mm fluh bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved muninipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: (DSR-17.3/2013) 590 W.C. pan with ISI marked white solid plastic seat and lid (DSR-17.3.1/2013) 591 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430X260X350mm and 340X410X265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting an making good the walls and floors wherever required. (DSR-17.4/2013) 592 One urinal basin with 5 litre white PVC automatic flushing cistern (DSR-17.4.1/2013) 593 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. (DSR-17.7/2013) 594 White Vitreous China Wash basin size 630X450mm with a pair of 15mm C.P. brass pillar taps (DSR-17.7.1/2013) 595 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the receptin of pipes and fittings (DSR-17.8/2013) 596 Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete (DSR-17.28/2013) 597 Flexible pipe (DSR-17.28.2/2013) 598 32mm dia (DSR-17.28.2.1/2013) 599 Providing and fixing 600X450 mm beveled edge mirror of superrior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete (DSR-17.31/2013) 600 SUB HEAD-XII:- WATER SUPPLY 601 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (DSR-18.8/2013) 602 Concealed work, including cutting chases and making good the wall etc. 603 20 mm nominal outer dia Pipes (DSR-18.8.2/2013) 604 25 mm nominal outer dia Pipes (DSR-18.8.3/2013) 605 32 mm nominal outer dia Pipes (DSR-18.8.4/2013) 606 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement trenching, refilling & testing of joints complete as per direction of E/I. (DSR-18.9/2013) 607 100 mm nominal inner dia Pipes (DSR-18.9.9/2013) 608 150 mm nominal inner dia Pipes (DSR-18.9.10/2013) 609 Providing and fixing C.P. brass bib cock of approved quality conforming to IS :8931 (DSR-18.49/2013) 610 15mm nominal bore (DSR-18.49.1/2013) 611 Providing and fixing C.P. brass stop cock (conceale) of standard design and of approved make conforming to IS:8931 (DSR-18.52/2013) 612 15mm nominal bore (DSR-18.52.1/2013) 613 SUB HEAD - XIV - DRAINAGE 614 Making soak pit 2.5 m diameter 3.0 metre deep with 45X45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100mm diameter, 1.8m long complete as per standard design (DSR-19.32/2013) 615 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.32.1/2013) 616 Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. (DSR-19.7/2013) 617 Inside size 90X80 cm and 45 cm deep including C.I. cover with frame (light duty) 455X610mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg.) (DSR-19.7.1/2013) 618 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.7.1.1/2013) 619 Extra for depth for manholes: (DSR-19.8/2013) 620 Size 90X80 cm (DSR-19.8.1/2013) 621 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.8.1.1/2013) 622 SUB HEAD -XV : - ALUMINIUM WORK 623 Providing and fixing aluminium work for door, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and joined mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/stainless steel screw, all complete as per architectural drawings and the directions of Engineer-in-charge (Glazing and paneling to be paid for separately) (DSR-21.1/2013) 624 For fixed portion (DSR-21.1.1/2013) 625 Powder coated Aluminum (minimum thickness of powder coating 50 micron) (DSR-21.1.1.2/2013) 626 For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required (fittings shall be paid for separately) (DSR-21.1.2/2013) 627 Powder coated Aluminum (minimum thickness of powder coating 50 micron)(DSR-21.1.2.2/2013) 628 Providing and fixing glazing in luminium door, windows, ventilator, shutters and partitions etc. with PVC/neoprene gasket etc. complete as per the architectural drawings an the directions of the E/I (Cost of aluminium snap beading shall be paid in basic item) (DSR-21.3/2013) 629 With float glass panes of 4.0mm thickness (DSR-21.3.1/2013) 630 With float glass panes of 5.50mm thickness (DSR-21.3.2/2013) 631 Filling the gap in between aluminuim frame & adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of E/I complete (DSR-21.8/2013) 632 Upto 5mm depth and 5mm width (DSR-21.8.1/2013) 633 SUB HEAD -XVI-WATER PROOFING WORK 634 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water profing compound conforming to IS. 2645 and approved by E/I over the RCC slab inclding adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admided with watr proofing compound conforming to IS 2645 and approved by E/I over 20mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) 635 admixed with water proofing compound conforming to IS : 2645 and approved by E/I to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) after two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by E/I finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by E/I including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300X300 mm square 3mm deep) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curring and for final test. All above operations to be done in order and as directed and specified by the E/I. (DSR-22.7/2013) 636 With average thickness of 120mm and minimum thickness at Khurra as 65mm (DSR-22.7.1/2013) 637 Providing and laying integral cement based treatment for waterproofing on horizontal surface at all depth below ground level for under ground structures as directed by E/I and consisting of : i) Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement 3 coarse sand) mixed with water proofing compound confirming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately) Joints saled and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (DSR-22.1/2013) 638 Using rough kota stone (DSR-22.1.1/2013) 639 Providing and laying integral cement based treatment for waterproofing on the vertical surface by fixing specified stone slab 22mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gap with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement 3 coarse sand) 20mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all level and as direction by E/I. (DSR-22.2/2013) 640 Using rough kota stone (DSR-22.2.1/2013) 641 SUBMERSIBLE PUMP WITH MOTOR 642 Supply, Erection, testing and commissioning of Submersible pump with CI casing,CF8 M impeller , SS 410 shaft, CI casing wearing ring & bearing bush, TC/ SIC mechanical seal, SS strainer etc suitable for3phase,415V,50Hz,ACsupply,submersible motor having TEFC enclosure with class H/F insulationasperspecsandIP68protection.The pump shall be operatedat suitable rpm as per data sheet.Thescopeincludesallrequiredaccessories viz. automaticcouplingdevice,G.Iguidepipe,chain with shakle, flat/ round submersible cable upto starterpanelthroughsuitablesizeG.I.pipewith necessary electrical connection with the starter panel and as per specifications 643 Capacity: 550 M³/hr 644 Head : 42 mtrs. 645 Motor Rating: 110 KW 646 VALVES 647 MOTOR OPERATED SLUICE VALVE 648 Supply,installation,testingandcommissioningof motor operated double flanged, C.I. Sluice Valve 649 Size : 400mm NB forPump Discharge Line 650 Size : 600mm NB forHeader 651 Size : 450mm NB for OHT 652 Size : 450mm NB for OHT 653 CHECK VALVE 654 Cast iron double flanged Single Door Swing CheckValve 655 Size : 400mm NB forPump Discharge Line 656 KINETIC AIR VALVE 657 Supply,Installation,testing&commissioningofC.I. doubleactingkineticAirValvewithisolationsluicevalve. 658 Size : 150mm NB 659 MANIFOLD PIPE & PIPE SPECIALS 660 Supply, Fabrication, laying, testing and commissioningof M.S.pipe&specialswith necessary supports & anchoring and including nuts,bolts and hardware 661 Size : 400mm NB forPump Discharge Line 662 Size : 600mm NB forHeader 663 Supply, Fabrication, Fitting, testing and commissioning ofMetallic Expansion Joint with necessary supports & anchoring and including nuts,bolts and hardware 664 Size : 400mm NB forPump Discharge Line 665 Supply, Fabrication, laying, testing and commissioning of pipe fittings and specials includingNuts, bolts and hardware 666 DEWATERINGPUMP 667 Supply, installation,testing&commissioningofnon clog submersible dewateringpump to remove sand, silt,clay,sand,pebbles,smallrock,algae,shells, plankton,etc.(withspecificgravityofupto1.1) having CI casing, CF8 M impeller , SS 410 shaft, CI casingwearingring&bearingbush,suitablefor3 phase, 415 V, 50 Hz, AC supply, submersible motor having TEFC enclosure with class H/F insulation as perspecsandIP68protection.Thepumpshallbe operatedatsuitablerpmasperdatasheetwithall required accessories. 668 Capacity: 50 mtr3/hr. 669 Head : 10 mtrs. 670 Motor Rating: 3.7KW 671 E.O.T. CRANE WITH HOIST 672 Supply,erection, testing and commissioning offully electrically operated hoist, geared trolley, gantry girder,brake,safetydevice,lockingarrangement, limit switch, pendant push button, starter panel, cables,and other required accessories. 673 Capacity : 5.0 Ton. For Pump room 674 Span : 9.5 mtrs. 675 Lift :10.00 mtrs. (min) 676 Supply,erection, testing and commissioning offully electrically operated hoist, geared trolley, gantry girder,brake,safetydevice,lockingarrangement, limit switch, pendant push button, starter panel, cables,and other required accessories. 677 Capacity : 2.0 Ton. 678 Lift :5.00 mtrs. (min) 679 CHLORINATION PLANT 680 Supply, installation, testing & commissioning of vacuum control floor mounted gas chlorinator system including necessary fittings, clamp, copper pipe, ferule filter & control valve with injector with required booster pump, set of diffuser entire associated water &chlorinesoulutionpipinguptodiffuseretc, valves,automaticchangeover,Chlorineabsorption system,saftey&testingkit,etc.completeinall respect as per specs & as per following capacity 681 Capacity : 2 x 5 kg/hr 682 Supply,erection, testing and commissioning of single girder electrically operated hoist, geared trolley,brake,safetydevice,lockingarrangement, limit switch, pendant push button, starter panel, cables,and other required accessories. 683 Capacity : 3.0 Ton.for Chlorination plant 684 Span : 5.0 mtrs.(max) 685 Lift :10.00 mtrs. (min) 686 900 kg. Chlorine Tonners duly approvedby dept. ofexplosive 687 ELECTRICAL WORK 688 H.T. INDOOR SWITCH GEAR PANEL 689 Supply,Installation,TestingandCommissioning(SITC)of11 kV, 350 MVA, 400 A, indoor,drawout type Three HT Vaccuum Circuit Breaker Panel (single breaker) withCT and PT ofappropriate rating for meteringand protectionalongwith required Indicating lamps, protection relay and Indicating meters, etc. complete in all respects as per IS, Specification. 690 H.V. CABLES 691 Supply, delivery, laying testing &commissioning of11KV(E), XLPEcablehavingcompactedcircularstarandedaluminium conductor,conductorscreeningofextrudedsemiconducting compound, cross linked polythylane (XLPE), insulation screening oftheextruded semi conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098 (Part-amendments)forfollowingmentionedsizes.Itshouldbe operational at 11 KV, 50 Hz. AC system in ground at a depth of 1200 mm below ground level over a cushion of 75 mm thick sand alround and protected with bricks on sides and 692 top on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directedbytheE/I.Completeinallrespect.Thepriceare inclusive of all earth work such as digging, back filling, supply & spreading of good earth all around the cable, supply & providing cable identification markers. The installation should be complete in all respects and as per requirement of the job. 693 (CCI (Bombay/Nashik), Fort Gloster (Calcutta / Baripara), Asian (Thane/Silvasha),Universal(Satna),Nicco(Calcutta),ICL (Rajpura), Diamond, Havells make SOR-3 694 3CX240 Sqmm. 695 Supply, Delivery,Installation, Testing & Commissioningof 11KV, indoor type cable termination kit of 3 core cable for cable termination at the panel & transformer complete in all respects as required for proper completion of work. (450mm length) SOR-5 (make Raychem/C.C.I./Frontec)d) 3CX240 Sq.mm. 696 DISTRIBUTION TRANSFORMER 697 Supply,delivery, assembly, installation,testingand commissioning of indoor type distribution transformer. 11/0.433 KV, 3 Phase, Double wound winding. Voltage ratio 11000/433-250Volts,vectorgroupDyn11.Aircooledwithmanually operated +5% and +10% off load Tap changer and complete with standardfitting&accessoriesasgiveninthespecificationand also confirming to ISS : 2026 with firsh filling of the oil complete as required. (This includes oil testing for dielectric strength, flask over test and filtration of transformer oil to be conducted in the event of unsatisfactory results of oil testing. (Crompton, NGEF, Alstom,BHEL,Voltamp,Diamond,Reychem,Kanoharmake) SOR-13Copper wound(a) 400 KVA 698 Supply and levelling of transformer yard using gravel, fine sand andotherrequiredfilingmaterial,enmarked fortheswitchyard includingremoving oftrees orboulders ifany etc.Thegeneral level of the yard shall be at a convenient level for movement of man and material and it should match with FGL. 699 Supply and Installation of Chain link fencing around switch yardetc. as per Specification. 700 SITC of 2.5 mtr wide gate with required material as perSpecification. 701 SITC of Medium Voltage Panel Board 702 MEDIUM VOLTAGE PANEL BOARD 703 Panel Board Encloser & Bus-Bar 704 Supplying,Installation,TestingandCommissioningofIndoor floormountedtotallyenclosed, compartmentalized,extendable type PCC / PMCC / MCC Cubicle Panel Board having 36 MVA, 50Abreakingcapacity ofsuitablesizefabricatedfromCRCA steel of 2 mm thickfor frame work, enclosure and doors, 3 mm thickforglandplateswithstiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, withsuitableelectrolyticgradehighconductivityPVCsleeved aluminium(E91-E)busbarsshallbesizedformaximum 0.8 A/mm2 current density, 705 extensibletype, DMC/SMC busbar supports, suitable for 3 phase-neutral 415 V,50 HZ AC supply i/c providingand fixingthefollowingswitchgearsmounted thereon complete with gaskets and interconnections, connections asperspecificationscomplete asrequired.(Theboardshallbe dust&vermin proofwithdegree ofprotection ofIP52asper IS:12063,freestandingtype,mountedonbasechannelofMS Sectionnotlessthan100mmX50mmX5mm),Isolated cubical compartment for fixed capacitors and as per IS, Specification & Single Line Diagram. (Mini.5.5M length X 1M Min.Width X Maximum 2.3M Height with base channel) 706 630rating4StripPVCSleeved Aluminium(E91-E)Bus-bar (AllbusbarsshallbeconsideringMaximum CurrentDensity 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (8 Mtr.) 707 Incoming Section 708 Incomer Breaker for Transformer (Qty.1 Nos.) 709 4 Pole ACB - 630A, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.) 710 3-Phase Digital Type Multifunction Meter (96x96Sqmm.), Accuracy. Class-0.5S (for Active)suitable to measure kVA, kW, kWH, kVAr, kVArH, A,V, P.F. & Frequency and with RS 485 Communication Portformonitoring &operation fromremote / PLC with suitable Software. - (1 Nos.) 711 630/5A, CL 0.5, 15VA for Metering CTs - (3 Nos.) 712 630/5A, CL.0.5 15VA, CTs for APFC relay - (3 Nos.) 713 On/Off/Trip/SpringchargeLEDtypeIndicationLamp, 220VAC 22.5mm. - (4 Nos.) 714 Control HRC fuses with fuse base (6A) - (6 Nos.) 715 R,Y,B Led Indication Lamp, 220VAC 22.5mm, - (3 Nos.) 716 Digital Voltmeter ( 0-500 V) with control fuses. - (1 Nos.) 717 Digital Ammeter ( 0-630 A) with control fuses. - (1 Nos.) 718 Selectro Switch (For Ammeter & Voltmeter) - (2 Nos.) 719 DG Incomer Breaker D.G (Qty.1 No.) 720 4 Pole ACB - 630A, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.) 721 630/5A, CL 0.5, 15VA, Metering CTs - (3 Nos.) 722 On/Off/Trip/SpringchargeLEDtypeIndicationLamp, 220VAC 22.5mm. - (4 Nos.) 723 Control HRC fuses with fuse base (6A) - (3 Nos.) 724 R,Y,B Led Indication Lamp, 220VAC 22.5mm - (3 Nos.) 725 Digital Voltmeter ( 0-500V) with control fuses. - (1 Nos.) 726 Digital Ammeter ( 0-630A) with control fuses. - (1 Nos.) 727 Selectro Switch (For Ammeter & Voltmeter) - (2 Nos.) 728 Transformer No-load losses comp. Fixed Capacitors forTran. (Qty.1 Nos.) 729 63A 3P MCB, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.) 730 20 kVAR Capacitor Duty Contactor - (1 Nos.) 731 Timer for Capacitor - (1 Nos.) 732 R,Y,B Led Indication Lamp, 220VAC 22.5mm - (3 Nos.) 733 On LED type Indication Lamp, 220VAC 22.5mm. - (1 Nos.) 734 Control HRC fuses with fuse base (6A) - (6 Nos.) 735 20A MCB for Capacitor - (1 Nos.) 736 16A MCB for Capacitor - (1 Nos.) 737 6A MCB for Capacitor - (1 Nos.) 738 10 kVAR APP. Type Capacitor - (1 Nos.) 739 10 kVAR APP. Type Capacitor - (1 Nos.) 740 3 kVAR APP. Type Capacitor - (1 Nos.) 741 Outgoing Section 742 210A Soft-Starter for 132kW (Suitable for 110kW Moto after derating)FeederEachComprisingoffollowing:(Qty.3 Sets.) 743 350A TP MCCB, 36 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.) 744 325A Three Pole AC-3 duty line Contactor - (1 Nos.) 745 630ASemiconductor(FA)Bussmannfusetype170M5012& Fuse Holder-170H3004 - (3 Nos.) 746 210ASoft-Starterfor132kW(Suitablefor110kWMotoafter derating) - (1 Nos.) 747 325A Three Pole AC-3 duty By Pass Contactor of Soft Starter - (1 Nos.) 748 350/5A, CL 0.5, Metering CTs - (3 Nos.) 749 On / Off / Trip LED type Indication Lamp, 220VAC 22.5mm. - (3 Nos.) 750 Stat Push Button - (1 Nos.) 751 Stop Push Button - (1 Nos.) 752 Digital Ammeter ( 0-350A) with control fuses. - (1 Nos.) 753 Selectro Switch (Ammeter) - (1 Nos.) 754 Selectro Switch (Auto/Manual, Local/remote) - (2 Nos.) 755 Pump Protection Unit - (1 Nos.) 756 (MPR + SPP) with CBCT - (1 Nos.) 757 2.5A TP MPCB with Thermostate and 2 nos. Cooling fan (CFM-105) for Starter Enclosure etc. - (1 Lot) 758 APFCPanelfeeder(For105kVARAPFCPanel)-(Qty.1No.) 759 200 A TPN MCCB, 36 kA, with Micro Processor based release & rotary handle etc. - (1 Nos.) 760 On / Off LED type Indication Lamp, 220VAC 22.5mm. - (2 Nos.) 761 63 A (415V) TPN "C" Curve MCB Feeders - (2 Nos.) 762 32 A (415V) TPN "C" Curve MCB Feeders - (10 Nos.) 763 Power Feeders 764 32 TPN MCB Feeders for Incomer - (1 Nos.) 765 On/OffLEDtype Indication Lamp,220VAC22.5mmfor(a) Incommer - (2 Nos.) 766 6A TPN "C" Curve MCB - (6 Nos.) 767 Miscellaneousaccessories 768 Terminals,Jumperwires,Controlwiring,HRCfuselinkwith ControlFuse,Spaceheater,ControlTransformer,Illumination lamp and all other required Panel Miscellaneousaccessories etc.. - (1 Lot) 769 i) Provide monimum 4 Nos. or 20% spare terminals which ever is higher for control cables.ii)ProvideterminalsforTripinterlockforfutureuse.(Spare shall be supplied with short link) - (1 Lot) 770 Note: i) Auto/Manual and Local / Remote selector switches shall beprovidedforallstarterswhichshalloperatethroughPLC whenselectedinAutoMode.Inmanualmodethedriveshall operate through manually through MCC-PB or through LCS-PB. When Local / Remote switch is selected in local mode or remote moderespectively.Potentialfreecontactsshallbeprovidedto monitordrivestatussignals(A/Mswitchstatus,driveOn/Off status and drive trip status) at PLC.ii)Lowlevelswitchfordryrunprotectionpumpsshallbe interlockedatrespectivestartersthroughprovisionofrequired relays and relay based logic for pumps tripping at ICP. 771 APFC PANEL BOARD (105 kVAR - 8 STEP) 772 Panel Board Encloser & Bus-Bar 773 Supplying,Installation,TestingandCommissioningofIndoor floormountedtotallyenclosed, compartmentalizedtypeAPFC CubiclePanelBoardhaving36MVAbreakingcapacity of suitablesizefabricatedfromCRCAsteelof2mmthick for framework,enclosureanddoors,3mmthickforglandplates with stiffeners wherever required, having vibration free structure chemicallytreatedwithseventankprocessbeforepaintingfor surfacetreatmentandpowdercoated,withsuitableelectrolytic grade high conductivity PVC sleeved aluminium (E91-E) busbars shall be sized for maximum0.8 A/mm2 current density, extensible type, DMC/SMC 774 busbar supports, suitable for 3 phase- neutral415V,50HZACsupplyI/cprovidingandfixingthe following switchgears&capacitorsmounted thereoncomplete withgasketsandinterconnections,connectionsasper specifications complete as required. (The APFC Panel board shall be dust & vermin proof with degree of protection of IP 42 as per IS:12063,freestandingtype,mountedonbasechannelofMS Section not less than 100 mm X 50 mm X 5 mm) and as per IS, Specification (Mini.1.2M length X Min. 750M Width X Maximum 2M Height with base channel) 775 200A rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (AllbusbarsshallbeconsideringMaximum CurrentDensity 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (2.00 Mtr) 776 Incoming Section 777 Incomer Breaker for APFC (Qty. 1 No.) 778 200 A 3P+N MCCB, 36 kA, with Micro Processor based release& rotary handle etc. - (1 Nos) 779 LED type Indication Lamp, 220VAC 22.5mm dia. For On / Off /Trip - (3 Nos) 780 LED type Indication Lamp, 220VAC 22.5mm For R, Y, B - (3 Nos) 781 HRCControlfuseswithfusebase(6A)forvoltmeter, Ameter,APFC relay - (9 Nos) 782 Digital Voltmeter (0-500V) - (1 Nos) 783 200/5A, CL-1, 15VA, Metering CTs - (3 Nos) 784 Digital Ammeter (0-200A) - (1 Nos) 785 Selectro Switch (For Auto / Manual) - (1 Nos) 786 APFC Relay 787 8-Step Microprocessor Based APFC Relay - (1 Nos) 788 Outgoing Section 789 20kVARCapacitorsfeedersEachComprisingoffollowing:(Qty. 2 Sets.) 790 40A 3P MCB for Capacitor - (1 Nos) 791 20kVAR Capacitor Duty Contactor - (1 Nos) 792 Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos) 793 LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos) 794 20kVAR Double layer APP Type Capacitor - (1 Nos) 795 15kVARCapacitorsfeedersEachComprisingoffollowing:(Qty. 2 Sets.) 796 32A 3P MCB for Capacitor - (1 Nos) 797 15kVAR Capacitor Duty Contactor - (1 Nos) 798 Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos) 799 LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos) 800 15kVAR Double layer APP Type Capacitor - (1 Nos) 801 10kVAR Capacitors feeders,Each Comprising offollowing:(Qty. 3 Sets.) 802 32A 3P MCB for Capacitor - (1 Nos) 803 10kVAR Capacitor Duty Contactor - (1 Nos) 804 Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos) 805 LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos) 806 10kVAR Double layer APP Type Capacitor - (1 Nos) 807 5kVAR Capacitors feeders, Qty. 1 No. 808 16A 3P MCB for Capacitor - (1 Nos) 809 5kVAR Capacitor Duty Contactor - (1 Nos) 810 Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos) 811 LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos) 812 5kVAR Double layer APP. Type Capacitor - (1 Nos) 813 MiscellaneousAPFC Panel Accessories 814 Terminals,Jumperwires,Controlwiring,HRCfuselinkwith ControlFuse,Spaceheater,ControlTransformer,Illumination lamp and all other required Panel Miscellaneousaccessories etc.. - (1 Lot) 815 Provide monimum 4 Nos. or 20% spare terminals which ever ishigher for control cables. - (1 Lot) 816 Note: Auto/Manual selector switches shall be provided for Auto/Manual mode of opearation to operate APFC Panel through APFCRelay whenselected inAutoMode&inmanualy when selected Manual mode. - (1 Lot) 817 LDB / PDB / JB / LCS 818 SITC of Lighting Distribution Board as under:Supplying and fixing of following ways surface/ recess mounting, verticaltype,415volts,TPNMCBdistributionboardofsheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Single door 819 Incoming Section 820 Supplying and fixing following rating, four pole, (three phase and neutral),415volts,residualcurrentcircuitbreaker(RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 821 Outgoing Section 822 Supplying andfixing 5ampsto32ampsrating,240/415volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 823 SITC of Outdoor Lighting Distribution Board as under: Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/recess complete withloose wire box of sheet steel, dust protected,dulypowderpainted,inclusiveof200ampstinned copperbusbar,commonneutrallink,earthbar,dinbarfor mountingMCB’s, terminalconnectorsforall incomingand outgoing circuits, duly prewired with adequate size of FRLS PVC insulatedcopperconductor uptotheterminalconnector/ neutral link, earthing etc. as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way Double door 824 Incoming Section 825 Supplying and fixing following rating, four pole, (three phase and neutral),415volts,residualcurrentcircuitbreaker(RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 826 32A Contactor 827 Time switch. 828 Outgoing Section 829 Supplying andfixing 5ampsto32ampsrating,240/415volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 830 SITC of Power Distribution Board as under:Supplying and fixing following way prewired vertical type TP&N MCBdistribution boardof steel sheet for415volts on surface/ recess complete with loose wire box of sheet steel, dust protected, dulypowderpainted,inclusiveof200ampstinnedcopperbus bar, commonneutrallink, earthbar, din bar formounting MCB’s,terminal connectors for all incoming andoutgoing circuits, duly prewired with adequate size of FRLS PVC insulatedcopperconductor uptotheterminalconnector/ neutral link, earthing etc. as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way Single door 831 Incoming Section 832 Supplying andfixing 5ampsto32ampsrating,240/415volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 833 Outgoing Section 834 Supplying andfixing 5ampsto32ampsrating,240/415volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 835 SITCofstand/wallmountingJunctionBox withProtection Class of IP-65, fault level-25kA with steel structure stand etc. for Terminationof1.1kVSubmersibleFlexibleCopperPower& Control cable with (A) One run 3C x 185 sq.mm A2XFY power cable. 836 SITCofstand/wallmountingJunctionBox withProtection Class of IP-65, fault level-25kA with steel structure stand etc. for Termination of 1.1 kV Submersible Flexible Copper Power and / or Control cable with (A) 5C x 2.5/1.5 sq.mm ywy control cable. 837 SITCofPendanttypeON_OFFpushbuttonsetcompletewith Enclouser,necessarymounting/fixing arrangementonwall/ pipe support etc. to be installed near motors for remote operation, etc. as per IS and specifications 838 MEDIUM VOLTAGE CABLES 839 Supply & laying of aluminum conductor PVC insulated armoured servedsheathedcables1100Voltsgrateatadepthofbelow ground level over a cushion of 75 mm. below ground level over a cushion of 75 mm. thick sand all round and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer– in charge, complete in all respected. The armouring of the cable shallbe properly connected withthe earth conductor by clamps etc. 840 300sq. mm. 3-1/2 core 841 185sq. mm. 3-1/2 core 842 150sq. mm. 3-1/2 core 843 6 sq.mm. 4 core 844 4 sq.mm. 3 core 845 SITCof1.1kV,YWY/PVCinsulated(IS1554)Cuconductor cables as per specification & IS. 846 3C x 2.5 sq. mm. YWY Cable 847 4C x 2.5 sq. mm. YWY Cable 848 5C x 1.5 sq.mm. YWY Cable 849 10C x 1.5 sq.mm. YWY Cable 850 CABLE END TERMINATION AND CONNECTION: 851 Supplyingandmakingendterminationwithbrasscompression glandandaluminiumlugsforfollowingsizeofPVCinsulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV gradeas required. 852 3½ X 300 sq. mm (70mm) 853 3½ X 185 sq. mm (57mm) 854 3½ X 150 sq. mm (50mm) 855 Supply & fixing of brass nickel plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects .The armoured of the cable shall be properly connected with the earth as per direction of Engineer – in charge. 856 6sq.mm. 4 core 857 4sq.mm. 3 core 858 Supply & fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respects as per direction of Engineer – in charge. 859 6sq.mm. 860 4sq.mm. 861 Supplyingandmakingendterminationwithbrasscompression glandandcopper lugsforfollowing sizeofPVCinsulatedand PVC sheathed copper conductor cable of 1.1kV gradeas required. 862 3C x 2.5 sq. mm. YWY Cable 863 4C x 2.5 sq. mm. YWY Cable 864 5C x 1.5 sq.mm. YWY Cable 865 10C x 1.5 sq.mm. YWY Cable 866 CABLETRAY 867 Supplying and installing following size of perforated pre-paintedM.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceilingwithM.S.suspendersincludingbolts&nuts,painting suspenders etc as required. 868 450 mm width X 62.5 mm depth X 2.0 mm thickness 869 300 mm width X 62.5 mm depth X 2.0 mm thickness 870 150 mm width X 50 mm depth X 1.6 mm thickness 871 EARTHING 872 Earthingwithcopperearthplate600mmX600mmX3mm thickincludingaccessories,andprovidingmasonryenclosure with cover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. 873 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories,andprovidingmasonryenclosurewithcoverplate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 874 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. 875 Supplyingandlaying25mmX5mmG.Istripat0.50metre belowgroundasstripearthelectrode,includingconnection/ terminatingwithG.I.nut,bolt,spring,washeretc.asrequired. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 876 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 877 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 878 50 x 6 GI strips 879 INTERNALWIRING 880 Wiringforlightpoint/fanpoint /exhaust fanpoint /callbell pointwith1.5sq.mmFRLSPVCinsulatedcopperconductor singlecorecablein surface/ recessedmediumclass PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 881 Supply and wiring of submain with four no. 2.5 sq.mm. FR PVC insulated 1100 V grade multistrand single core copper conductor cable in25mm diaheavy duty (2mm thick)PVCconduit with two no. 1.5 sq.mm. FR PVC insulated 1100 V grade multistrand copperconductorasearthcontinuitywiredrawn insidethe conduit. 882 Wiring for Circuit / Submain wiring along with earth wire with the (2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire) sizes of FRLS insulated copper conductor, Single core cable in Surface / recessed medium class PVC Conduit as required. 883 Supplyandfixingof25mmsizesofmediumClassPVC Conduit alongwith accessories in surface/recess including cuttingthewallandmaking good thesame incaseofrecessed conduit as required. 884 Wiring for twincontrol lightpoint with1.5sq.mm FRLSPVC insulated copper conductor single core cable in surface / recessed mediumclassPVCconduit,2waymodularswitch,modular plate,suitableGIboxandearthingthepointwith1.5sq.mm. FRLSPVCinsulatedcopper conductor single core cableetcas required. 885 Supply and fixing of following size / modules, GI Box along with modular base & cover plate for modular switches in recess etc. as required.(For 15/16A and 5A/6A Switch & Socket) 886 (a) 8 Module (125mm x 125mm) 887 (b) 3 Module (100mm x 75mm) 888 Supply and fixing of following Modular Switch / Socket on the modular plate & Switch box including connections but excluding modular plate etc. as required. 889 6 pin 15/16 Amp Socket outlet 890 15/16 Amp Switch 891 3 pin 5/6 Amp Socket outlet 892 5/6 Amp Switch 893 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 894 Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (Pump house & Panel room) 895 Supplying andfixing TPsheet steel enclosure on surface/recess along with 16/25/32amps 415 volts “C” curve TP MCB complete withconnections,testingandcommissioningetc.asrequired. (For Ele. Hoist etc.) 896 INTERNAL LIGHT FIXTURES 897 Supply and fixing of factory wired HPF industrial type fluorescenttubelightfittingwithvitreousenameledreflector suitablefor2X40wfluorescenttubeincludingtubesetc.on surface complete in all respects.Cat AA (seg.) 898 Supplyandfixingoffactorywired,surfacetypemirroroptic fittingsmadeofpreanodizedaluminiumsectionwithP2/P5 louvers suitable for & with 2no.36 w CFL complete in all respect. Cat AA 899 Supply and fixing of factory wired asymmetrical beamed integral floodlightluminaireswithdiecastaluminiumhousing&A1.reflector havingbuiltincontrolgearunitdulyprewiredplate complete with ballast, ignitor ,capacitor for 1*150 w M.H. with lamp complete in all respect.Cat AA 900 Supplyandfixingofindustrialbulkheadfittingwith polycarbonate base guard, prismatic reflector silicon gasket suitable for and with 1X18 w CFL complete in all respect.Cat A 901 380mmsweep1400R.P.Mexhaustfan,capacitortype, having double ball bearing, M.S.blades, mounting frame, forearms, suitable to operate on 230V,50 HZ AC supply conforming to IS: 2312.Fanshallbe painted withepoxy grey colour controlled by one 6 A flush type switch on board and 6A plug point near Ex. fan. 902 1200mmsweepceilingfan,capacitortype,havingdoubleball bearing 450mm down rod, canopies, shackle, rubber bush, blades, electronic speed regulator, suitable to operate on 230V,50Hz AC supply conforming to IS: 374/1979.Fan shall be painted with white colour. 903 EXTERNAL LIGHT FIXTURES 904 Supply and fixing of factory wired asymmetrical beamed integral floodlightluminaireswithdiecastaluminiumhousing&A1.reflector havingbuiltincontrolgearunitdulyprewiredplate complete withballast,ignitor ,capacitor for 1*150W M.H. with lamp complete in all respect.Cat AA 905 Supply &erection of Steel tubularsingle wing pole with30cm around&1/6overalllengthofpolegroutedwithcement concretein1:3:6(1cement:3coarsesand:6stoneballast) including plinthing of pole &15cm around &30 cm above the groundlevel,plasteringofplinthincludingexcavationback fillingetc.Theratesincludesallmaterialslabour&T&P.etc. requiredforpropercompletion ofworkasperdirectionofE/I.SOR-20a) 410 SP-17, 8.5mtr., 92kg. 906 Supplyandfixingoffactorywiredsodiumvapourlampstreet light luminaries single piece cast “Aluminium” body suitable for 70w S.V. lamp including integral control gear, 70w S.V. lamp onG.I. pipe bracket complete in all respects on on pole. 907 Supply and fixing of H.P.M.V. post top lantern, suitable for 80wM.V. lamp complete with control gear pole mounting box and 80 w M.V. lamps etc. complete in all respects.Cat AA (seg.) 908 DIESEL GENERATOR WITH AMF PANEL SET 909 SITCOFDIESELGENERATORWITHENGINE,ALTERNATOR & DG CONTROLLER SET 910 SITCof365KVADGsetorhigherrating(asrequiredtorun completeworkingloadofpumpingstationincludinglighting.)415 V,50 Hz,3 Phase, 4 wire Diesel Generator (Engine, Alternator & DG Controller) Set. Diesel engine shall be complete with necessary controls and safety devices confirming to relevent ISS/BSS with latest amendements. Diesel Engine shall be suitable for continuous operation of generator set duty inclusive offly wheel, aircleaner, radiator.fan withguard,fuel pump,fuel filter,Electronic governor,electrical starting system with starter,12 Vbattery,voltageregulator,instrument panel,Exhaustsilencer, protections against low lubrication oil pressure,high water temperature. 911 Alternatorshallbe415V,3phase,50Hz,4wire,0.8power factor,selfexcited,self regulated,brushless type,drip proof confirmingtoIS:4722withlatestamendments.DGsetshall complylatestemissionnormsofMinistryofEnvironment& Forest(MOEF)byGovernmentofIndia,effectivefromJuly 2014. DG set engine shall be manufactured as per present CPCB norms.DGsetratingshallbeforprimeratingpower(PRP)in accordancewithBS5514/IS/ISO.DGsetshallmeetall statutory/ pollution control regulationrequirementwith all currently applicable statutory norms, regulations and safety codes of the latest applicable Indian Standards. 912 The engine and alternator shall be coupled over a sturdy common base frame. Day fuel tank with necessary fuel to hoses the engine fule and complete in all respect as required. DG set shall be along with acoustic enclosure / canopy and suitable for outdoor mounting. 913 SITC OF AMF PANEL 914 Panel Board Encloser & Bus-Bar 915 Supplying,Installation,TestingandCommissioningofIndoor floormountedtotallyenclosed, compartmentalized,extendable typeAMF Panel Board having36 MVA, 50 kA breaking capacity ofsuitablesizefabricatedfrom CRCAsteel of2mm thickfor frame work, enclosure and doors, 3 mm thick for gland plateswithstiffenerswhereverrequired,havingvibrationfree structure chemicallytreatedwith seventank processbefore paintingforsurfacetreatment andpowdercoated, with electrolytic grade high conductivity PVC sleeved aluminium (E91 916 E)busbars,DMC/SMCbusbarsupports,suitablefor3phase- neutral415V,50HZACsupplyi/cprovidingandfixingthe followingswitchgearsmountedthereoncompletewithgaskets and interconnections, connections as per specifications complete as required. (The board shall be dust & vermin proof with degree ofprotectionofIP52asperIS:12063,freestandingtype, mounted on base channel of MS Section not less than 100 mm X 917 50 mm X 5 mm), Isolated cubical compartmentfor fixed capacitors and as per IS, Specification & Single Line Diagram. (Mini.0.8M lengthX 0.75M Min.WidthX Maximum2.3M Height with base channel) 918 630A rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (AllbusbarsshallbeconsideringMaximum CurrentDensity 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (1.50 Mtr) 919 DG Incomer Breaker, (Qty. 1 Set) 920 4Pole ACB - 630A, 50 kA, with Micro Processor based releases (Overload, Short Circuit and earth fault protetive release) etc. - (1 Set) 921 3-Phase Digital Type Multifunction Meter (96x96Sqmm.), AccuracyClass-1,suitabletomeasureA,V,P.F.&Frequency and with RS 485 Communication Port for monitoring & operation from remote / PLC with suitable Software. - (1 Nos) 922 3-Phase Digital Type Trivector / Energy Meter, Accuracy Class- 0.5S(ForActive), suitabletomeasure kVA,kW,kWH,kVAr, kVArH, P.F. & Frequency and with RS 485 Communication Port formonitoring&operationfromremote/PLCwithsuitable Software. - (1 Nos) 923 630/5A, Core-1 CL 0.5, 15VA for Metering - (3 Nos) 924 Control HRC fuses with fuse base (6A) - (6 Nos) 925 Digital Voltmeter (0-500V) with control fuses. - (1 Nos) 926 Digital Ammeter (0-630A) with control fuses. - (1 Nos) 927 LED type Indication Lamp, 220VAC 22.5mm for On / Off / Trip/ Spring charge - (4 Nos) 928 LED Indication Lamp, 220VAC 22.5mm for R,Y,B - (3 Nos) 929 LED Indication Lamp, 220VAC 22.5mm for Load ON, Control ON, Breaker ON & OFF - (4 Nos) 930 Push Button for Engine Start & Stop, Emergency Stop, ACB Trip& Closed, Hooter Accept - (6 Nos) 931 Selectro Switch for Ammeter, Voltmeter, Control Supply On&Off, Auto-Manual mode, Local-Rermote (PLC) mode. - (5 Nos) 932 Automatic Mains Failure (AMF) Digital Relay - (1 Nos) 933 Line Voltage Monitoring digital Relay - (1 Nos) 934 Fully Automatic Battery Charger - (1 Nos) 935 Digital type DC Voltmeter (0-50V) - (1 Nos) 936 Digital type DC Ammeter (0-10A) - (1 Nos) 937 DC Control HRC fuses with fuse base (6A) - (6 Nos) 938 DC Selectro Switch (For Battery Charger On&Off) - (1 Nos) 939 Miscellaneousaccessories 940 Terminals,Jumperwires,Controlwiring,HRCfuselinkwith ControlFuse,MCBs,AuxiliaryRealys,AuxiliaryContactors, Spaceheaters,Controltransformer,Illuminationlampsandall other required Panel Miscellaneousaccessories etc. - (1 Lot) 941 Provide minimum 4Nos. or 20%spare terminals whichever ishigher for control cables. - (1 Lot) 942 Note:Auto-ManualselectorswitchandLocal-Remote(PLC) selectorswitchshallbeprovidedforeachAMFPanel,when selected in Auto mode, the panel shall operate through AMF relay & in manual mode, the Panel shall operate through manually, in manual mode through local-remote selector switch, in local mode panelshalloperatethroughPanelPush-Buttonandinremote mode, panel shall operate through PLC. 943 SAFETYACCESSORIES 944 Supply and fixing of fire extinguisher, dry chemical type 5.00 kg. Capacity(ISImark)completeswithinitialchargeandwall bracket, along with supply of all materials and labour for proper completion of work. 945 Providing and fixing H.T. danger notice plate of 250mmX200mm, madeofmildsteel,atleast2mmthick,and vitreousenameledwhiteonbothsides,andwithinscriptionin single red colour on front side as required. 946 Providing and fixing M.V. danger notice plate of 200mmX150mm, madeofmildsteel,atleast2mmthick,and vitreousenameledwhiteonbothsides,andwithinscriptionin single red colour on front side as required. 947 Supply and fixing of shock treatment chart(prescribed under I.E. rules) duly framed with glass and supported from back with hard boardorsoftboardwithsupply ofallmaterial labourT&Pfor proper completion of work. 948 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11litrescapacitydulypaintedasperfirebrigadedesign, supported on hanging bracket chained and locked, initially filled withfineriversand,waterasperdirectionsofEngineer-in- charge. 949 Supply and layfing of 1800mmX900mmX12mm thick chequered rubber matting of tested quality. 950 First Aid box. 951 Supply and fixing of20 Wfluorescent lampoperated emergencylightwithmaintenancefreebatteryfor3hoursopeation during mains power failure. 952 11 kV Rubber Hand Gloves 953 STRUCTURE STEEL 954 Supply&InstallationofStructureSteelrequiredforsupport structureofequipments, LCS,cable,cabletray&earthingetc. forsupportonfloor/wall/beam/bracketsetc.including required welding/ cutting/ grinding shall be done to complete the job. 955 INSTRUMENT WORK 956 PRESSURE MEASURMENT SYSTEM 957 Supply, installation, testing & commissioning of 958 Pressuretransmitterwith indicator& all accessories 959 at delivery of each Pump and common header. 960 Range : 0 - 10 kg / sq.cm. 961 PRESSUREGUAGE 962 Supply, installation, testing & commissioning of 963 Bourdanpressureguagehaving150mmdialwith 964 necessaryS.S.cock at delivery line of each Pump. 965 Range : 0 - 10 kg / sq.cm. 966 PRESSURESWITCH 967 Supply, installation, testing & commissioning of 968 Pressure switchat delivery line of each Pump. 969 Range : 0 - 10 kg / sq.cm.(Adjustable type) 970 FLOWMEASURING SYSTEM 971 Supply,installation, testing and commissioning of 972 Electromagnetictype flow meterwith indiactor,transmitter andtotaliserwithallaccessoriesand, 973 hardwares, etc.complete in all respects. 974 Size : 450 for manifold size 450 mm of R18 Header 975 LEVEL MEASURING SYSTEM 976 Supply, installation, testing & commissioning 977 Ultrasonic type Level transmitter with indicator andall 978 requiredaccessories& hardwares, etc. completein 979 all respects. 980 Range : 0 - 6 Mtrs.Supply, installation, testing & commissioning of Float 981 & Board type level indicator with all accessories. 982 Range : 0 - 6 Mtrs.Supply, installation, testing & commissioning of Float 983 typelevelswitch withallaccessoriesforDryrun 984 protection of pumps. Range : 0 - 10 Mtrs. 985 FRC ANALYZERSupply, installation, testing & commissioning of Amperometrictype FreeChlorineAnalyzer complete withtransmitter,sensor,sensorcable,Sensor mountingassembly ,accessories, hardware,consumables, etc. complete in all respects.Measuring Range : 0 - 5 mg/L 986 PLC / SCADA FOR CONTROL ROOM 987 Supply,installation, testing and commissioning of PLC-SCADA system including Instrument control Panel,PCbasedHMIalongwith19"colourLCD Screen, Required programming/ SCADA/Application Software, A3 Size Laser Printer, GSM-GPRS / BroadbandbasedcommunicationforRemoteData Transmission,Min.1kVA UPS (with 30min backup alongwithsuitable rating SMFbatteries &battery chargerand allotheraccessoriesasperstandard), etc.completeinallrespectsandasper specifications. PLC shall have I/O count of44 DI / 18 DO / 12 AI / 0AO. 988 INSTRUMENT CABLES 989 Supply,laying,testingandcommissioningof Instrument Cables including termination & Trays 990 3C X 2.5 sq.mm YWY Power cable 991 1PX 1.5sq.mmCu.Conductor,armoured,overall& individual shieldedSignal cable 992 2C X 1.5 sq.mmCu. Conductor,armoured ,overallshielded Control cable 993 10CX1.5sq.mmCu.Conductor,armoured,overall shielded Control cable 994 INSTRUMENT CABLETRAY 995 Supplyingandinstallingfollowingsizeofperforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors,suspendedfromtheceilingwithM.S. suspenders including bolts & nuts, paintingsuspenders etc as required. 996 100 mm width X 50 mm depth X 1.6 mm thickness 997 200 mm width X 50 mm depth X 1.6 mm thickness 998 CABLE END TERMINATION AND CONNECTION: 999 Supplyingandmakingendterminationwithbrass compression gland and copper lugs for following size ofPVCinsulatedandPVCsheathedcopperconductor cable of 1.1kV gradeas required. 1000 POWER CABLE 1001 3C x 2.5 sq.mm 1002 CONTROL CABLE 1003 2C x 1.5 sq.mm 1004 10C x 1.5 sq.mm 1005 SIGNAL CABLE 1006 1P x 1.5 sq.mm. 1007 ZONAL RESERVOIR (R16)CIVIL WORK 1008 SUB HEAD :- ERARTH WORK 1009 CARRIAGE OF MATERIALS (DSR-1.0/2013) 1010 By Mechanical Transport including loading, unloading and stacking (DSR-1.1/2013) 1011 Earth (10km) (DSR-1.1.2/2013) 1012 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areaa (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m diposed earth to be levelled and neatly dressed. (DSR-2.6/2013) 1013 All kinds of soil (DSR-2.6.1/2013) 1014 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5m. (DSR-2.25/2013) 1015 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR-2.27/2013) 1016 Clearing grass and removal of the rbbish upto a distance of 50m outside the periphery of the area cleared. (DSR-2.32/2013) 1017 SUB HEAD-II :- CONCRETE WORKS 1018 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR-4.1/2013) 1019 1:4:8 (1 Cement :4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm (DSR-4.1.8/2013) 1020 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mmnominal size) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (DSR-4.17/2013) 1021 SUB HEAD-III :- REINFORCED CEMENT CONCRETE WORK 1022 Centering and shuttering including including strutting, propping etc. and removal of form for all heights including forming grooves as and whereever requried as per drawing. (DSR-5.9/2013) 1023 Foundations, footings, bases of columns, etc. for mass concrete. (DSR-5.9.1/2013) 1024 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR-5.9.2/2013) 1025 Suspended floors, roofs, landings, balconies and access platform (DSR-5.9.3/2013) 1026 Shelves (Cast in situ) (DSR-5.9.4/2013) 1027 Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR-5.9.5/2013) 1028 Columns, Pillars, Piers, Abutments, Posts and Struts (DSR-5.9.6/2013) 1029 Stairs, (excluding landings) except spiral-staircases (DSR-5.9.7/2013) 1030 Edges of slabs and breaks in floors and walls. (DSR-5.9.16/2013) 1031 Under 20cms wide (DSR-5.9.16.1/2013) 1032 Cornices and mouldings (DSR-5.9.17/2013) 1033 Weather shade, chajjas, corbels etc. including edges. (DSR-5.9.19/2013) 1034 STEEL REINFORCEMENT 1035 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR-5.22/2013) 1036 Thermo-Mechanically Treated bars(DSR-5.22.6/2013) (Sail Steel) 1037 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (DSR-5.22A/2013) 1038 Thermo-Mechanically Treated bars (DSR-5.22A.6/2013) (Sail Steel) 1039 Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections. (DSR-5.30/2013) 1040 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. "(Note :-Cement content considered in this item is @ 330 kg/cum."Excess/less cement used as per design mix is payable/recoverable separately). (DSR-5.33/2013) 1041 (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). 1042 All works upto plinth level (DSR-5.33.1/2013) 1043 All works above plinth level upto floor V level (DSR-5.33.2/2013) 1044 Extra for providing richer mixes at all floor levels. (DSR-5.34/2013) 1045 Note :- Excess/less cement over the specified cement content used is payable/recoverable separately. 1046 Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:-Cement content considered inM-30 is @ 340 kg/cum) (DSR-5.34.1/2013) 1047 Providing M-40 grade concrete instead of M-25 grade BMC/RMC. (Note :- Cement content considered in M-40 is @ 360 kg/cum) (DSR-5.34.3/2013) 1048 SUB HEAD-IV :- BRICK WORK 1049 Brick work with non modular fly ash bricks conforming to IS:12894, class designation10 average compressive strength in super structure above plinth level up to floor V level in : (DSR-6.34/2013) 1050 Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.34.2/2013) 1051 SUB HEAD-VII :- WOOD AND PVC WORK 1052 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, window and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR-9.12/2013) 1053 SUB HEAD-VIII :- STEEL WORK 1054 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part-1 and M.S. top cover of required thickness for rolling shutters. (DSR-10.6/2013) 1055 80X1.25 mm M.S. laths with 1.25 mm thick top cover (DSR-10.6.1/2013) 1056 Providing and fixing ball bearing for rolling shutters. (DSR-10.7/2013) 1057 Extra for providing mechanical device chain and crank operation for operating rolling shutters. (DSR-10.8/2013) 1058 Exceeding 10.00 sqm and upto 16.80 sqm in the area. (DSR-10.8.1/2013) 1059 Extra for provding grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in-charge (area of grill to be measured). (DSR-10.9/2013) 1060 SUB HEAD IX :- FLOORING 1061 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR-11.3/2013) 1062 40mm thick with 20mm nominal size stone aggregate. (DSR-11.3.1/2013) 1063 Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement :3 coarses sand) finished with a floating coat of neat cement (DSR-11.6/2013) 1064 18 mm thick (DSR-11.6.1/2013) 1065 Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) (DSR-11.26/2013) 1066 25mm thick (DSR-11.26.1/2013) 1067 Kota stone slabs 20mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polising complete. (DSR-11.27/2013) 1068 Extra for pre finished nosing in treads of steps of Kota stone/sand stone slabs. (DSR-11.31/2013) 1069 Extra for kota stone/sand stone in treads of steps and risers using single length up to 1.05 metre. (DSR-11.32/2013) 1070 Providing and laying vitrified floor tilies in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR-11.41/2013) 1071 Size of Tile 600X 600 mm (DSR-11.41.2/2013) 1072 Providing and laying vitrified tilies in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR-11.46/2013) 1073 Size of Tile 600X 600 mm (DSR-11.46.2/2013) 1074 SUB HEAD- X ROOFING 1075 Providing gola 75X75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (DSR-12.21/2013) 1076 In 75X75 mm deep chase (DSR-12.21.1/2013) 1077 Providing and laying roof insulation with 40mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulaton conforming to IS- 12432 Pt. III (density of foam being 40-50 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providng a wearing coursed of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20mm nominal size) in chequeredrough finish, in panels of 2.5m X 2.5m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. (DSR-12.56/2013) 1078 ROOFING SUB HEAD TOTAL 1079 SUB HEAD-XI :- FINISHING WORK 1080 12mm cement plaster of mix : (DSR-13.1/2013) 1081 1:6 (1 cement : 6 fine sand) (DSR-13.1.2/2013) 1082 6 mm cement plaster of mix : (DSR-13.16/2013) 1083 1:3 (1 cement : 3 fine sand) (DSR-13.16.1/2013) 1084 18 mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) (DSR-13.11/2013) 1085 Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: (DSR-13.24/2013) 1086 Is one coats (DSR-13.24.1/2013) 1087 Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR-13.80/2013) 1088 Colour washing such as green, blue or buff to give an even shade (DSR-13.39/2013) 1089 New work (two or more coats) with a base coat of white washing with lime (DSR-13.39.1/2013) 1090 Finishing with epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat,preparation of surface, etc. complete. (DSR-13.52/2013) 1091 on steel work (DSR-13.52.1/2013) 1092 On concrete work (DSR-13.52.2/2013) 1093 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour. (DSR-13.81/2013) 1094 Two coats (DSR-13.81.2/2013) 1095 SUB HEAD-XII:- SANITARY INSTALLATIONS 1096 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vetreous china flushing cistrn & C.P. flush bend with fittings & C.I. brackets, 40mm fluh bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved muninipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: (DSR-17.3/2013) 1097 W.C. pan with ISI marked white solid plastic seat and lid (DSR-17.3.1/2013) 1098 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430X260X350mm and 340X410X265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting an making good the walls and floors wherever required. (DSR-17.4/2013) 1099 One urinal basin with 5 litre white PVC automatic flushing cistern (DSR-17.4.1/2013) 1100 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. (DSR-17.7/2013) 1101 White Vitreous China Wash basin size 630X450mm with a pair of 15mm C.P. brass pillar taps (DSR-17.7.1/2013) 1102 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the receptin of pipes and fittings (DSR-17.8/2013) 1103 Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete (DSR-17.28/2013) 1104 Flexible pipe (DSR-17.28.2/2013) 1105 32mm dia (DSR-17.28.2.1/2013) 1106 Providing and fixing 600X450 mm beveled edge mirror of superrior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete (DSR-17.31/2013) 1107 SUB HEAD-XII:- WATER SUPPLY 1108 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (DSR-18.8/2013) 1109 Concealed work, including cutting chases and making good the wall etc. 1110 20 mm nominal outer dia Pipes (DSR-18.8.2/2013) 1111 25 mm nominal outer dia Pipes (DSR-18.8.3/2013) 1112 32 mm nominal outer dia Pipes (DSR-18.8.4/2013) 1113 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement trenching, refilling & testing of joints complete as per direction of E/I. (DSR-18.9/2013) 1114 100 mm nominal inner dia Pipes (DSR-18.9.9/2013) 1115 150 mm nominal inner dia Pipes (DSR-18.9.10/2013) 1116 Providing and fixing C.P. brass bib cock of approved quality conforming to IS :8931 (DSR-18.49/2013) 1117 15mm nominal bore (DSR-18.49.1/2013) 1118 Providing and fixing C.P. brass stop cock (conceale) of standard design and of approved make conforming to IS:8931 (DSR-18.52/2013) 1119 15mm nominal bore (DSR-18.52.1/2013) 1120 SUB HEAD - XIV - DRAINAGE 1121 Making soak pit 2.5 m diameter 3.0 metre deep with 45X45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100mm diameter, 1.8m long complete as per standard design (DSR-19.32/2013) 1122 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.32.1/2013) 1123 Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. (DSR-19.7/2013) 1124 Inside size 90X80 cm and 45 cm deep including C.I. cover with frame (light duty) 455X610mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg.) (DSR-19.7.1/2013) 1125 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.7.1.1/2013) 1126 Extra for depth for manholes: (DSR-19.8/2013) 1127 Size 90X80 cm (DSR-19.8.1/2013) 1128 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.8.1.1/2013) 1129 SUB HEAD -XV : - ALUMINIUM WORK 1130 Providing and fixing aluminium work for door, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and joined mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/stainless steel screw, all complete as per architectural drawings and the directions of Engineer-in-charge (Glazing and paneling to be paid for separately) (DSR-21.1/2013) 1131 For fixed portion (DSR-21.1.1/2013) 1132 Powder coated Aluminum (minimum thickness of powder coating 50 micron) (DSR-21.1.1.2/2013) 1133 For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required (fittings shall be paid for separately) (DSR-21.1.2/2013) 1134 Powder coated Aluminum (minimum thickness of powder coating 50 micron)(DSR-21.1.2.2/2013) 1135 Providing and fixing glazing in luminium door, windows, ventilator, shutters and partitions etc. with PVC/neoprene gasket etc. complete as per the architectural drawings an the directions of the E/I (Cost of aluminium snap beading shall be paid in basic item) (DSR-21.3/2013) 1136 With float glass panes of 4.0mm thickness (DSR-21.3.1/2013) 1137 With float glass panes of 5.50mm thickness (DSR-21.3.2/2013) 1138 Filling the gap in between aluminuim frame & adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of E/I complete (DSR-21.8/2013) 1139 Upto 5mm depth and 5mm width (DSR-21.8.1/2013) 1140 SUB HEAD -XVI-WATER PROOFING WORK 1141 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water profing compound conforming to IS. 2645 and approved by E/I over the RCC slab inclding adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admided with watr proofing compound conforming to IS 2645 and approved by E/I over 20mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) 1142 admixed with water proofing compound conforming to IS : 2645 and approved by E/I to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) after two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by E/I finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by E/I including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300X300 mm square 3mm deep) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curring and for final test. All above operations to be done in order and as directed and specified by the E/I. (DSR-22.7/2013) 1143 With average thickness of 120mm and minimum thickness at Khurra as 65mm (DSR-22.7.1/2013) 1144 Providing and laying integral cement based treatment for waterproofing on horizontal surface at all depth below ground level for under ground structures as directed by E/I and consisting of : i) Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement 3 coarse sand) mixed with water proofing compound confirming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately) Joints saled and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (DSR-22.1/2013) 1145 Using rough kota stone (DSR-22.1.1/2013) 1146 Providing and laying integral cement based treatment for waterproofing on the vertical surface by fixing specified stone slab 22mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gap with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement 3 coarse sand) 20mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all level and as direction by E/I. (DSR-22.2/2013) 1147 Using rough kota stone (DSR-22.2.1/2013) 1148 SUBMERSIBLE PUMP WITH MOTOR 1149 Supply, Erection, testing and commissioning of Submersible pump with CI casing,CF8 M impeller , SS 410 shaft, CI casing wearing ring & bearing bush, TC/ SIC mechanical seal, SS strainer etc suitable for3phase,415V,50Hz,ACsupply,submersible motor having TEFC enclosure with class H/F insulationasperspecsandIP68protection.The pump shall be operatedat suitable rpm as per data sheet.Thescopeincludesallrequiredaccessories viz. automaticcouplingdevice,G.Iguidepipe,chain with shakle, flat/ round submersible cable upto starterpanelthroughsuitablesizeG.I.pipewith necessary electrical connection with the starter panel and as per specifications 1150 Capacity: 500 M³/hr 1151 Head : 42 mtrs. 1152 Motor Rating: 110 KW 1153 VALVES 1154 MOTOR OPERATED SLUICE VALVE 1155 Supply,installation,testingandcommissioningof motor operated double flanged, C.I. Sluice Valve 1156 Size : 350mm NB forPump Discharge Line 1157 Size : 700mm NB forHeader 1158 Size : 500mm NB for Techzone-IV & VILL OHT 1159 Size : 200mm NB for Sector- III (C) OHT 1160 Size : 350mm NB for Sector-2 & VILL OHT 1161 Size : 350mm NB for Sector-2 & VILL & Sec-3 (R) 1162 CHECK VALVE 1163 Cast iron double flanged Single Door Swing CheckValve 1164 Size : 350mm NB forPump Discharge Line 1165 KINETIC AIR VALVE 1166 Supply,Installation,testing&commissioningofC.I. doubleactingkineticAirValvewithisolationsluicevalve. 1167 Size : 150mm NB 1168 MANIFOLD PIPE & PIPE SPECIALS 1169 Supply, Fabrication, laying, testing and commissioningof M.S.pipe&specialswith necessary supports & anchoring and including nuts,bolts and hardware 1170 Size : 350mm NB forPump Discharge Line 1171 Size : 700mm NB forHeader 1172 Supply, Fabrication, Fitting, testing and commissioning ofMetallic Expansion Joint with necessary supports & anchoring and including nuts,bolts and hardware 1173 Size : 350mm NB forPump Discharge Line 1174 Supply, Fabrication, laying, testing and commissioning of pipe fittings and specials includingNuts, bolts and hardware 1175 DEWATERINGPUMP 1176 Supply, installation,testing&commissioningofnon clog submersible dewateringpump to remove sand, silt,clay,sand,pebbles,smallrock,algae,shells, plankton,etc.(withspecificgravityofupto1.1) having CI casing, CF8 M impeller , SS 410 shaft, CI casingwearingring&bearingbush,suitablefor3 phase, 415 V, 50 Hz, AC supply, submersible motor having TEFC enclosure with class H/F insulation as perspecsandIP68protection.Thepumpshallbe operatedatsuitablerpmasperdatasheetwithall required accessories. 1177 Capacity: 50 mtr3/hr. 1178 Head : 10 mtrs. 1179 Motor Rating: 3.7 KW 1180 E.O.T. CRANE WITH HOIST 1181 Supply,erection, testing and commissioning offully electrically operated hoist, geared trolley, gantry girder,brake,safetydevice,lockingarrangement, limit switch, pendant push button, starter panel, cables,and other required accessories. 1182 Capacity : 5.0 Ton. For Pump room 1183 Span : 9.5 mtrs. 1184 Lift :10.00 mtrs. (min) 1185 Supply,erection, testing and commissioning offully electrically operated hoist, geared trolley, gantry girder,brake,safetydevice,lockingarrangement, limit switch, pendant push button, starter panel, cables,and other required accessories. 1186 Capacity : 2.0 Ton. 1187 Lift :5.00 mtrs. (min) 1188 CHLORINATION PLANT 1189 Supply, installation, testing & commissioning of vacuum control floor mounted gas chlorinator system including necessary fittings, clamp, copper pipe, ferule filter & control valve with injector with required booster pump, set of diffuser entire associated water &chlorinesoulutionpipinguptodiffuseretc, valves,automaticchangeover,Chlorineabsorption system,saftey&testingkit,etc.completeinall respect as per specs & as per following capacity 1190 Capacity : 2 x 5 kg/hr 1191 Supply,erection, testing and commissioning of single girder electrically operated hoist, geared trolley,brake,safetydevice,lockingarrangement, limit switch, pendant push button, starter panel, cables,and other required accessories. 1192 Capacity : 3.0 Ton.for Chlorination plant 1193 Span : 5.0 mtrs.(max) 1194 Lift :10.00 mtrs. (min) 1195 900 kg. Chlorine Tonners duly approvedby dept. ofexplosive 1196 ELECTRICAL WORK 1197 H.T. INDOOR SWITCH GEAR PANEL 1198 Supply,Installation,TestingandCommissioning(SITC)of11 kV, 350 MVA, 400 A, indoor,drawout type Three HT Vaccuum Circuit Breaker Panel (single breaker) withCT and PT ofappropriate rating for meteringand protectionalongwith required Indicating lamps, protection relay and Indicating meters, etc. complete in all respects as per IS, Specification. 1199 H.V. CABLES 1200 Supply, delivery, laying testing &commissioning of11KV(E), XLPEcablehavingcompactedcircularstarandedaluminium conductor,conductorscreeningofextrudedsemiconducting compound, cross linked polythylane (XLPE), insulation screening oftheextruded semi conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098 (Part-amendments)forfollowingmentionedsizes.Itshouldbe operational at 11 KV, 50 Hz. AC system in ground at a depth of 1200 mm below ground level over a cushion of 75 mm thick sand alround and protected with bricks on sides and 1201 top on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directedbytheE/I.Completeinallrespect.Thepriceare inclusive of all earth work such as digging, back filling, supply & spreading of good earth all around the cable, supply & providing cable identification markers. The installation should be complete in all respects and as per requirement of the job. 1202 (CCI (Bombay/Nashik), Fort Gloster (Calcutta / Baripara), Asian (Thane/Silvasha),Universal(Satna),Nicco(Calcutta),ICL (Rajpura), Diamond, Havells make SOR-3 1203 3CX240 Sqmm. 1204 Supply, Delivery,Installation, Testing & Commissioningof 11KV, indoor type cable termination kit of 3 core cable for cable termination at the panel & transformer complete in all respects as required for proper completion of work. (450mm length) SOR-5 (make Raychem/C.C.I./Frontec)d) 3CX240 Sq.mm. 1205 DISTRIBUTION TRANSFORMER 1206 Supply,delivery, assembly, installation,testingand commissioning of indoor type distribution transformer. 11/0.433 KV, 3 Phase, Double wound winding. Voltage ratio 11000/433-250Volts,vectorgroupDyn11.Aircooledwithmanually operated +5% and +10% off load Tap changer and complete with standardfitting&accessoriesasgiveninthespecificationand also confirming to ISS : 2026 with firsh filling of the oil complete as required. (This includes oil testing for dielectric strength, flask over test and filtration of transformer oil to be conducted in the event of unsatisfactory results of oil testing. (Crompton, NGEF, Alstom,BHEL,Voltamp,Diamond,Reychem,Kanoharmake) SOR-13Copper wound(b) 630 KVA 1207 Supply and levelling of transformer yard using gravel, fine sand andotherrequiredfilingmaterial,enmarked fortheswitchyard includingremoving oftrees orboulders ifany etc.Thegeneral level of the yard shall be at a convenient level for movement of man and material and it should match with FGL. 1208 Supply and Installation of Chain link fencing around switch yardetc. as per Specification. 1209 SITC of 2.5 mtr wide gate with required material as perSpecification. 1210 SITC of Medium Voltage Panel Board 1211 MEDIUM VOLTAGE PANEL BOARD 1212 Panel Board Encloser & Bus-Bar 1213 Supplying,Installation,TestingandCommissioningofIndoor floormountedtotallyenclosed, compartmentalized,extendable type PCC / PMCC / MCC Cubicle Panel Board having 36 MVA, 50Abreakingcapacity ofsuitablesizefabricatedfromCRCA steel of 2 mm thickfor frame work, enclosure and doors, 3 mm thickforglandplateswithstiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, withsuitableelectrolyticgradehighconductivityPVCsleeved aluminium(E91-E)busbarsshallbesizedformaximum 0.8 A/mm2 current density, 1214 extensibletype, DMC/SMC busbar supports, suitable for 3 phase-neutral 415 V,50 HZ AC supply i/c providingand fixingthefollowingswitchgearsmounted thereon complete with gaskets and interconnections, connections asperspecificationscomplete asrequired.(Theboardshallbe dust&vermin proofwithdegree ofprotection ofIP52asper IS:12063,freestandingtype,mountedonbasechannelofMS Sectionnotlessthan100mmX50mmX5mm),Isolated cubical compartment for fixed capacitors and as per IS, Specification & Single Line Diagram. (Mini.6.8M length X 1M Min.Width X Maximum 2.3M Height with base channel) 1215 800rating4StripPVCSleeved Aluminium(E91-E)Bus-bar (AllbusbarsshallbeconsideringMaximum CurrentDensity 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (8.80 Mtr.) 1216 Incoming Section 1217 Incomer Breaker for Transformer (Qty.1 Nos.) 1218 4 Pole ACB - 800A, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.) 1219 3-Phase Digital Type Multifunction Meter (96x96Sqmm.), Accuracy. Class-0.5S (for Active)suitable to measure kVA, kW, kWH, kVAr, kVArH, A,V, P.F. & Frequency and with RS 485 Communication Portformonitoring &operation fromremote / PLC with suitable Software. - (1 Nos.) 1220 800/5A, CL 0.5, 15VA for Metering CTs - (3 Nos.) 1221 800/5A, CL.0.5 15VA, CTs for APFC relay - (3 Nos.) 1222 On/Off/Trip/SpringchargeLEDtypeIndicationLamp, 220VAC 22.5mm. - (4 Nos.) 1223 Control HRC fuses with fuse base (6A) - (6 Nos.) 1224 R,Y,B Led Indication Lamp, 220VAC 22.5mm, - (3 Nos.) 1225 Digital Voltmeter ( 0-500 V) with control fuses. - (1 Nos.) 1226 Digital Ammeter ( 0-800 A) with control fuses. - (1 Nos.) 1227 Selectro Switch (For Ammeter & Voltmeter) - (2 Nos.) 1228 DG Incomer Breaker D.G (Qty.1 No.) 1229 4 Pole ACB - 800A, 50 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.) 1230 800/5A, CL 0.5, 15VA, Metering CTs - (3 Nos.) 1231 On/Off/Trip/SpringchargeLEDtypeIndicationLamp, 220VAC 22.5mm. - (4 Nos.) 1232 Control HRC fuses with fuse base (6A) - (3 Nos.) 1233 R,Y,B Led Indication Lamp, 220VAC 22.5mm - (3 Nos.) 1234 Digital Voltmeter ( 0-500V) with control fuses. - (1 Nos.) 1235 Digital Ammeter ( 0-800A) with control fuses. - (1 Nos.) 1236 Selectro Switch (For Ammeter & Voltmeter) - (2 Nos.) 1237 Transformer No-load losses comp. Fixed Capacitors forTran. (Qty.1 Nos.) 1238 63A3PMCB,50kA,withMicroProcessorbasedreleases& rotary handle etc. - (1 Nos.) 1239 25 kVAR Capacitor Duty Contactor - (1 Nos.) 1240 Timer for Capacitor - (1 Nos.) 1241 R,Y,B Led Indication Lamp, 220VAC 22.5mm - (3 Nos.) 1242 On LED type Indication Lamp, 220VAC 22.5mm. - (1 Nos.) 1243 Control HRC fuses with fuse base (6A) - (6 Nos.) 1244 32A MCB for Capacitor - (1 Nos.) 1245 20A MCB for Capacitor - (1 Nos.) 1246 4A MCB for Capacitor - (1 Nos.) 1247 15 kVAR APP. Type Capacitor - (1 Nos.) 1248 8 kVAR APP. Type Capacitor - (1 Nos.) 1249 2 kVAR APP. Type Capacitor - (1 Nos.) 1250 Outgoing Section 1251 210A Soft-Starter for 132kW (Suitable for 110kW Moto afterderating)FeederEachComprisingoffollowing:(Qty.5 Sets.) 1252 350A TP MCCB, 36 kA, with Micro Processor based releases & rotary handle etc. - (1 Nos.) 1253 325A Three Pole AC-3 duty line Contactor- (1 Nos.) 1254 630ASemiconductor(FA)Bussmannfusetype170M5012& Fuse Holder-170H3004 - (3 Nos.) 1255 210ASoft-Starterfor132kW(Suitablefor110kWMotoafter derating) - (1 Nos.) 1256 325A Three Pole AC-3 duty By Pass Contactor of Soft Starter - (1 Nos.) 1257 350/5A, CL 0.5, Metering CTs - (3 Nos.) 1258 On / Off / Trip LED type Indication Lamp, 220VAC 22.5mm. - (3 Nos.) 1259 Stat Push Button - (1 Nos.) 1260 Stop Push Button - (1 Nos.) 1261 Digital Ammeter ( 0-350A) with control fuses. - (1 Nos.) 1262 Selectro Switch (Ammeter) - (1 Nos.) 1263 Selectro Switch (Auto/Manual, Local/remote) - (2 Nos.) 1264 Pump Protection Unit - (1 Nos.) 1265 (MPR + SPP) with CBCT - (1 Nos.) 1266 2.5A TP MPCB with Thermostate and 2 nos. Cooling fan (CFM- 105) for Starter Enclosure etc. - (1 Lot) 1267 APFCPanelfeeder(For160kVARAPFCPanel)-(Qty.1 No.) 1268 315 A TPN MCCB, 36 kA, with Micro Processor based release & rotary handle etc. - (1 Nos.) 1269 On / Off LED type Indication Lamp, 220VAC 22.5mm. - (2 Nos.) 1270 63 A (415V) TPN "C" Curve MCB Feeders - (2 Nos.) 1271 32 A (415V) TPN "C" Curve MCB Feeders - (10 Nos.) 1272 Power Feeders 1273 32 TPN MCB Feeders for Incomer - (1 Nos.) 1274 On/OffLEDtype Indication Lamp,220VAC22.5mmfor(a) Incommer - (2 Nos.) 1275 6A TPN "C" Curve MCB - (6 Nos.) 1276 Miscellaneousaccessories 1277 Terminals,Jumperwires,Controlwiring,HRCfuselinkwith ControlFuse,Spaceheater,ControlTransformer,Illumination lamp and all other required Panel Miscellaneousaccessories etc.. - (1 Lot) 1278 i) Provide monimum 4 Nos. or 20% spare terminals which ever is higher for control cables.ii)ProvideterminalsforTripinterlockforfutureuse.(Spare shall be supplied with short link) - (1 Lot) 1279 Note: i) Auto/Manual and Local / Remote selector switches shall beprovidedforallstarterswhichshalloperatethroughPLC whenselectedinAutoMode.Inmanualmodethedriveshall operate through manually through MCC-PB or through LCS-PB. When Local / Remote switch is selected in local mode or remote moderespectively.Potentialfreecontactsshallbeprovidedto monitordrivestatussignals(A/Mswitchstatus,driveOn/Off status and drive trip status) at PLC.ii)Lowlevelswitchfordryrunprotectionpumpsshallbe interlockedatrespectivestartersthroughprovisionofrequired relays and relay based logic for pumps tripping at ICP. 1280 APFC PANEL BOARD (160 kVAR - 8 STEP) 1281 Panel Board Encloser & Bus-Bar 1282 Supplying,Installation,TestingandCommissioningofIndoor floormountedtotallyenclosed, compartmentalizedtypeAPFC CubiclePanelBoardhaving36MVAbreakingcapacity of suitablesizefabricatedfromCRCAsteelof2mmthick for framework,enclosureanddoors,3mmthickforglandplates with stiffeners wherever required, having vibration free structure chemicallytreatedwithseventankprocessbeforepaintingfor surfacetreatmentandpowdercoated,withsuitableelectrolytic grade high conductivity PVC sleeved aluminium (E91-E) busbars shall be sized for maximum0.8 A/mm2 current density, extensible type, DMC/SMC 1283 busbar supports, suitable for 3 phase- neutral415V,50HZACsupplyI/cprovidingandfixingthe following switchgears&capacitorsmounted thereoncomplete withgasketsandinterconnections,connectionsasper specifications complete as required. (The APFC Panel board shall be dust & vermin proof with degree of protection of IP 42 as per IS:12063,freestandingtype,mountedonbasechannelofMS Section not less than 100 mm X 50 mm X 5 mm) and as per IS, Specification (Mini.1.2M length X Min. 750M Width X Maximum 2M Height with base channel) 1284 315A rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (AllbusbarsshallbeconsideringMaximum CurrentDensity 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (2 Mtr.) 1285 Incoming Section 1286 Incomer Breaker for APFC (Qty. 1 No.) 1287 315A 3P+N MCCB, 36 kA, with Micro Processor based release & rotary handle etc. - (1 Nos.) 1288 LED type Indication Lamp, 220VAC 22.5mm dia. For On / Off /Trip - (3 Nos.) 1289 LED type Indication Lamp, 220VAC 22.5mm For R, Y, B - (3 Nos.) 1290 HRCControlfuseswithfusebase(6A)forvoltmeter, Ameter, APFC relay - (9 Nos.) 1291 Digital Voltmeter (0-500V) - (1 Nos.) 1292 200/5A, CL-1, 15VA, Metering CTs - (3 Nos.) 1293 Digital Ammeter (0-315A) - (1 Nos.) 1294 Selectro Switch (For Auto / Manual) - (1 Nos.) 1295 APFC Relay 1296 8-Step Microprocessor Based APFC Relay - (1 Nos.) 1297 Outgoing Section 1298 30kVARCapacitorsfeederseachComprisingoffollowing:(Qty. 3 Set.) 1299 63A 3P MCB for Capacitor - (1 Nos.) 1300 30kVAR Capacitor Duty Contactor - (1 Nos.) 1301 Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.) 1302 LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.) 1303 30kVAR Double layer APP Type Capacitor - (1 Nos.) 1304 20kVARCapacitorsfeederseachComprisingoffollowing:(Qty. 2 Set.) 1305 40A 3P MCB for Capacitor - (1 Nos.) 1306 20kVAR Capacitor Duty Contactor - (1 Nos.) 1307 Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.) 1308 LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.) 1309 20kVAR Double layer APP Type Capacitor - (1 Nos.) 1310 15kVAR Capacitors feeders, Qty. 1 No. 1311 32A 3P MCB for Capacitor - (1 Nos.) 1312 15kVAR Capacitor Duty Contactor - (1 Nos.) 1313 Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.) 1314 LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.) 1315 15kVAR Double layer APP Type Capacitor - (1 Nos.) 1316 10kVAR Capacitors feeders, Qty. 1 No. 1317 32A 3P MCB for Capacitor - (1 Nos.) 1318 10kVAR Capacitor Duty Contactor - (1 Nos.) 1319 Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.) 1320 LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.) 1321 10kVAR Double layer APP Type Capacitor - (1 Nos.) 1322 5kVAR Capacitors feeders, Qty. 1 No. 1323 16A 3P MCB for Capacitor - (1 Nos.) 1324 5kVAR Capacitor Duty Contactor - (1 Nos.) 1325 Push Button for Capacitor Stat / Stop (For Manual mode) - (2 Nos.) 1326 LED type Indication Lamp, 220VAC 22.5mm dia. for ON. - (1 Nos.) 1327 5kVAR Double layer APP. Type Capacitor - (1 Nos.) 1328 MiscellaneousAPFC Panel Accessories 1329 Terminals,Jumperwires,Controlwiring,HRCfuselinkwith ControlFuse,Spaceheater,ControlTransformer,Illumination lamp and all other required Panel Miscellaneousaccessories etc.. - (1 Lot) 1330 Provide monimum 4 Nos. or 20% spare terminals which ever is higher for control cables. - (1 Lot) 1331 Note: Auto/Manual selector switches shall be provided for Auto/Manual mode of opearation to operate APFC Panel through APFCRelay whenselected inAutoMode&inmanualy when selected Manual mode. - (1 Lot) 1332 LDB / PDB / JB / LCS 1333 SITC of Lighting Distribution Board as under:Supplying and fixing of following ways surface/ recess mounting, verticaltype,415volts,TPNMCBdistributionboardofsheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Single door 1334 Incoming Section 1335 Supplying and fixing following rating, four pole, (three phase and neutral),415volts,residualcurrentcircuitbreaker(RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 1336 Outgoing Section 1337 Supplying andfixing 5ampsto32ampsrating,240/415volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 1338 SITC of Outdoor Lighting Distribution Board as under: Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/recess complete withloose wire box of sheet steel, dust protected,dulypowderpainted,inclusiveof200ampstinned copperbusbar,commonneutrallink,earthbar,dinbarfor mountingMCB’s, terminalconnectorsforall incomingand outgoing circuits, duly prewired with adequate size of FRLS PVC insulatedcopperconductor uptotheterminalconnector/ neutral link, earthing etc. as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way Double door 1339 Incoming Section 1340 Supplying and fixing following rating, four pole, (three phase and neutral),415volts,residualcurrentcircuitbreaker(RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 1341 32A Contactor 1342 Time switch. 1343 Outgoing Section 1344 Supplying andfixing 5ampsto32ampsrating,240/415volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 1345 SITC of Power Distribution Board as under:Supplying and fixing following way prewired vertical type TP&N MCBdistribution boardof steel sheet for415volts on surface/ recess complete with loose wire box of sheet steel, dust protected, dulypowderpainted,inclusiveof200ampstinnedcopperbus bar, commonneutrallink, earthbar, din bar formounting MCB’s,terminal connectors for all incoming andoutgoing circuits, duly prewired with adequate size of FRLS PVC insulatedcopperconductor uptotheterminalconnector/ neutral link, earthing etc. as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way Single door 1346 Incoming Section 1347 Supplying andfixing 5ampsto32ampsrating,240/415volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 1348 Outgoing Section 1349 Supplying andfixing 5ampsto32ampsrating,240/415volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 1350 SITCofstand/wallmountingJunctionBox withProtection Class of IP-65, fault level-25kA with steel structure stand etc. for Terminationof1.1kVSubmersibleFlexibleCopperPower& Control cable with (A) One run 3C x 185 sq.mm A2XFY power cable. 1351 SITCofstand/wallmountingJunctionBox withProtection Class of IP-65, fault level-25kA with steel structure stand etc. for Termination of 1.1 kV Submersible Flexible Copper Power and / or Control cable with (A) 5C x 2.5/1.5 sq.mm ywy control cable. 1352 SITCofPendanttypeON_OFFpushbuttonsetcompletewith Enclouser,necessarymounting/fixing arrangementonwall/ pipe support etc. to be installed near motors for remote operation, etc. as per IS and specifications 1353 MEDIUM VOLTAGE CABLES 1354 Supply & laying of aluminum conductor PVC insulated armoured servedsheathedcables1100Voltsgrateatadepthofbelow ground level over a cushion of 75 mm. below ground level over a cushion of 75 mm. thick sand all round and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer– in charge, complete in all respected. The armouring of the cable shallbe properly connected withthe earth conductor by clamps etc. 1355 300sq. mm. 3-1/2 core 1356 185sq. mm. 3-1/2 core 1357 150sq. mm. 3-1/2 core 1358 6 sq.mm. 4 core 1359 4 sq.mm. 3 core 1360 SITCof1.1kV,YWY/PVCinsulated(IS1554)Cuconductor cables as per specification & IS. 1361 3C x 2.5 sq. mm. YWY Cable 1362 4C x 2.5 sq. mm. YWY Cable 1363 5C x 1.5 sq.mm. YWY Cable 1364 10C x 1.5 sq.mm. YWY Cable 1365 CABLE END TERMINATION AND CONNECTION: 1366 Supplyingandmakingendterminationwithbrasscompression glandandaluminiumlugsforfollowingsizeofPVCinsulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV gradeas required. 1367 3½ X 300 sq. mm (70mm) 1368 3½ X 185 sq. mm (57mm) 1369 3½ X 150 sq. mm (50mm) 1370 Supply & fixing of brass nickel plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects .The armoured of the cable shall be properly connected with the earth as per direction of Engineer – in charge. 1371 6sq.mm. 4 core 1372 4sq.mm. 3 core 1373 Supply & fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respects as per direction of Engineer – in charge. 1374 6sq.mm. 1375 4sq.mm. 1376 Supplyingandmakingendterminationwithbrasscompression glandandcopper lugsforfollowing sizeofPVCinsulatedand PVC sheathed copper conductor cable of 1.1kV gradeas required. 1377 3C x 2.5 sq. mm. YWY Cable 1378 4C x 2.5 sq. mm. YWY Cable 1379 5C x 1.5 sq.mm. YWY Cable 1380 10C x 1.5 sq.mm. YWY Cable 1381 CABLETRAY 1382 Supplying and installing following size of perforated pre-paintedM.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceilingwithM.S.suspendersincludingbolts&nuts,painting suspenders etc as required. 1383 450 mm width X 62.5 mm depth X 2.0 mm thickness 1384 300 mm width X 62.5 mm depth X 2.0 mm thickness 1385 150 mm width X 50 mm depth X 1.6 mm thickness 1386 EARTHING 1387 Earthingwithcopperearthplate600mmX600mmX3mm thickincludingaccessories,andprovidingmasonryenclosure with cover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. 1388 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories,andprovidingmasonryenclosurewithcoverplate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 1389 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. 1390 Supplyingandlaying25mmX5mmG.Istripat0.50metre belowgroundasstripearthelectrode,includingconnection/ terminatingwithG.I.nut,bolt,spring,washeretc.asrequired. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 1391 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 1392 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation andre-filling as required. 1393 50 x 6 GI strips 1394 INTERNALWIRING 1395 Wiringforlightpoint/fanpoint /exhaust fanpoint /callbell pointwith1.5sq.mmFRLSPVCinsulatedcopperconductor singlecorecablein surface/ recessedmediumclass PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 1396 Supply and wiring of submain with four no. 2.5 sq.mm. FR PVC insulated 1100 V grade multistrand single core copper conductor cable in25mm diaheavy duty (2mm thick)PVCconduit with two no. 1.5 sq.mm. FR PVC insulated 1100 V grade multistrand copperconductorasearthcontinuitywiredrawn insidethe conduit. 1397 Wiring for Circuit / Submain wiring along with earth wire with the (2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire) sizes of FRLS insulated copper conductor, Single core cable in Surface / recessed medium class PVC Conduit as required. 1398 Supplyandfixingof25mmsizesofmediumClassPVC Conduit alongwith accessories in surface/recess including cuttingthewallandmaking good thesame incaseofrecessed conduit as required. 1399 Wiring for twincontrol lightpoint with1.5sq.mm FRLSPVC insulated copper conductor single core cable in surface / recessed mediumclassPVCconduit,2waymodularswitch,modular plate,suitableGIboxandearthingthepointwith1.5sq.mm. FRLSPVCinsulatedcopper conductor single core cableetcas required. 1400 Supply and fixing of following size / modules, GI Box along with modular base & cover plate for modular switches in recess etc. as required.(For 15/16A and 5A/6A Switch & Socket) 1401 (a) 8 Module (125mm x 125mm) 1402 (b) 3 Module (100mm x 75mm) 1403 Supply and fixing of following Modular Switch / Socket on the modular plate & Switch box including connections but excluding modular plate etc. as required. 1404 6 pin 15/16 Amp Socket outlet 1405 15/16 Amp Switch 1406 3 pin 5/6 Amp Socket outlet 1407 5/6 Amp Switch 1408 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 1409 Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (Pump house & Panel room) 1410 Supplying andfixing TPsheet steel enclosure on surface/recess along with 16/25/32amps 415 volts “C” curve TP MCB complete withconnections,testingandcommissioningetc.asrequired. (For Ele. Hoist etc.) 1411 INTERNAL LIGHT FIXTURES 1412 Supply and fixing of factory wired HPF industrial type fluorescenttubelightfittingwithvitreousenameledreflector suitablefor2X40wfluorescenttubeincludingtubesetc.on surface complete in all respects.Cat AA (seg.) 1413 Supplyandfixingoffactorywired,surfacetypemirroroptic fittingsmadeofpreanodizedaluminiumsectionwithP2/P5 louvers suitable for & with 2no.36 w CFL complete in all respect. Cat AA 1414 Supply and fixing of factory wired asymmetrical beamed integral floodlightluminaireswithdiecastaluminiumhousing&A1.reflector havingbuiltincontrolgearunitdulyprewiredplate complete with ballast, ignitor ,capacitor for 1*150 w M.H. with lamp complete in all respect.Cat AA 1415 Supplyandfixingofindustrialbulkheadfittingwith polycarbonate base guard, prismatic reflector silicon gasket suitable for and with 1X18 w CFL complete in all respect.Cat A 1416 380mmsweep1400R.P.Mexhaustfan,capacitortype, having double ball bearing, M.S.blades, mounting frame, forearms, suitable to operate on 230V,50 HZ AC supply conforming to IS: 2312.Fanshallbe painted withepoxy grey colour controlled by one 6 A flush type switch on board and 6A plug point near Ex. fan. 1417 1200mmsweepceilingfan,capacitortype,havingdoubleball bearing 450mm down rod, canopies, shackle, rubber bush, blades, electronic speed regulator, suitable to operate on 230V,50Hz AC supply conforming to IS: 374/1979.Fan shall be painted with white colour. 1418 EXTERNAL LIGHT FIXTURES 1419 Supply and fixing of factory wired asymmetrical beamed integral floodlightluminaireswithdiecastaluminiumhousing&A1.reflector havingbuiltincontrolgearunitdulyprewiredplate complete withballast,ignitor ,capacitor for 1*150W M.H. with lamp complete in all respect.Cat AA 1420 Supply &erection of Steel tubularsingle wing pole with30cm around&1/6overalllengthofpolegroutedwithcement concretein1:3:6(1cement:3coarsesand:6stoneballast) including plinthing of pole &15cm around &30 cm above the groundlevel,plasteringofplinthincludingexcavationback fillingetc.Theratesincludesallmaterialslabour&T&P.etc. requiredforpropercompletion ofworkasperdirectionofE/I.SOR-20a) 410 SP-17, 8.5mtr., 92kg. 1421 Supplyandfixingoffactorywiredsodiumvapourlampstreet light luminaries single piece cast “Aluminium” body suitable for 70w S.V. lamp including integral control gear, 70w S.V. lamp onG.I. pipe bracket complete in all respects on on pole. 1422 Supply and fixing of H.P.M.V. post top lantern, suitable for 80wM.V. lamp complete with control gear pole mounting box and 80 w M.V. lamps etc. complete in all respects.Cat AA (seg.) 1423 DIESEL GENERATOR WITH AMF PANEL SET 1424 SITCOFDIESELGENERATORWITHENGINE,ALTERNATOR & DG CONTROLLER SET 1425 SITCof500KVADGsetorhigherrating(asrequiredtorun completeworkingloadofpumpingstationincludinglighting.)415 V,50 Hz,3 Phase, 4 wire Diesel Generator (Engine, Alternator & DG Controller) Set. Diesel engine shall be complete with necessary controls and safety devices confirming to relevent ISS/BSS with latest amendements. Diesel Engine shall be suitable for continuous operation of generator set duty inclusive offly wheel, aircleaner, radiator.fan withguard,fuel pump,fuel filter,Electronic governor,electrical starting system with starter,12 Vbattery,voltageregulator,instrument panel,Exhaustsilencer, protections against low lubrication oil pressure,high water temperature. 1426 Alternatorshallbe415V,3phase,50Hz,4wire,0.8power factor,selfexcited,self regulated,brushless type,drip proof confirmingtoIS:4722withlatestamendments.DGsetshall complylatestemissionnormsofMinistryofEnvironment& Forest(MOEF)byGovernmentofIndia,effectivefromJuly 2014. DG set engine shall be manufactured as per present CPCB norms.DGsetratingshallbeforprimeratingpower(PRP)in accordancewithBS5514/IS/ISO.DGsetshallmeetall statutory/ pollution control regulationrequirementwith all currently applicable statutory norms, regulations and safety codes of the latest applicable Indian Standards. 1427 The engine and alternator shall be coupled over a sturdy common base frame. Day fuel tank with necessary fuel to hoses the engine fule and complete in all respect as required. DG set shall be along with acoustic enclosure / canopy and suitable for outdoor mounting. 1428 SITC OF AMF PANEL 1429 Panel Board Encloser & Bus-Bar 1430 Supplying,Installation,TestingandCommissioningofIndoor floormountedtotallyenclosed, compartmentalized,extendable typeAMF Panel Board having36 MVA, 50 kA breaking capacity ofsuitablesizefabricatedfrom CRCAsteel of2mm thickfor frame work, enclosure and doors, 3 mm thick for gland plateswithstiffenerswhereverrequired,havingvibrationfree structure chemicallytreatedwith seventank processbefore paintingforsurfacetreatment andpowdercoated, with electrolytic grade high conductivity PVC sleeved aluminium (E91 1431 E)busbars,DMC/SMCbusbarsupports,suitablefor3phase- neutral415V,50HZACsupplyi/cprovidingandfixingthe followingswitchgearsmountedthereoncompletewithgaskets and interconnections, connections as per specifications complete as required. (The board shall be dust & vermin proof with degree ofprotectionofIP52asperIS:12063,freestandingtype, mounted on base channel of MS Section not less than 100 mm X 1432 50 mm X 5 mm), Isolated cubical compartmentfor fixed capacitors and as per IS, Specification & Single Line Diagram. (Mini.0.8M lengthX 0.75M Min.WidthX Maximum2.3M Height with base channel) 1433 800A rating 4 Strip PVC Sleeved Aluminium (E91-E) Bus-bar (AllbusbarsshallbeconsideringMaximum CurrentDensity 0.8A/mm2) suitable to fault level of 50kA for 1sec. - (1.50 Mtr.) 1434 DG Incomer Breaker, (Qty. 1 Set) 1435 4Pole ACB - 800A, 50 kA, with Micro Processor based releases (Overload, Short Circuit and earth fault protetive release) etc. - (1 Set) 1436 3-Phase Digital Type Multifunction Meter (96x96Sqmm.), AccuracyClass-1,suitabletomeasureA,V,P.F.&Frequency and with RS 485 Communication Port for monitoring & operation from remote / PLC with suitable Software. - (1 Nos.) 1437 3-Phase Digital Type Trivector / Energy Meter, Accuracy Class- 0.5S(ForActive), suitabletomeasure kVA,kW,kWH,kVAr, kVArH, P.F. & Frequency and with RS 485 Communication Port formonitoring&operationfromremote/PLCwithsuitable Software. - (1 Nos.) 1438 800/5A, Core-1 CL 0.5, 15VA for Metering - (3 Nos.) 1439 Control HRC fuses with fuse base (6A) - (6 Nos.) 1440 Digital Voltmeter (0-500V) with control fuses. - (1 Nos.) 1441 Digital Ammeter (0-800A) with control fuses. - (1 Nos.) 1442 LED type Indication Lamp, 220VAC 22.5mm for On / Off / Trip / Spring charge - (4 Nos.) 1443 LED Indication Lamp, 220VAC 22.5mm for R,Y,B - (3 Nos.) 1444 LED Indication Lamp, 220VAC 22.5mm for Load ON, Control ON, Breaker ON & OFF - (4 Nos.) 1445 Push Button for Engine Start & Stop, Emergency Stop, ACB Trip & Closed, Hooter Accept - (6 Nos.) 1446 Selectro Switch for Ammeter, Voltmeter, Control Supply On&Off, Auto-Manual mode, Local-Rermote (PLC) mode. - (5 Nos.) 1447 Automatic Mains Failure (AMF) Digital Relay - (1 Nos.) 1448 Line Voltage Monitoring digital Relay - (1 Nos.) 1449 Fully Automatic Battery Charger - (1 Nos.) 1450 Digital type DC Voltmeter (0-50V) - (1 Nos.) 1451 Digital type DC Ammeter (0-10A) - (1 Nos.) 1452 DC Control HRC fuses with fuse base (6A) - (6 Nos.) 1453 DC Selectro Switch (For Battery Charger On&Off) - (1 Nos.) 1454 Miscellaneousaccessories 1455 Terminals,Jumperwires,Controlwiring,HRCfuselinkwith ControlFuse,MCBs,AuxiliaryRealys,AuxiliaryContactors, Spaceheaters,Controltransformer,Illuminationlampsandall other required Panel Miscellaneousaccessories etc. - (1 Lot) 1456 Provide minimum 4Nos. or 20%spare terminals whichever is higher for control cables. - (1 Lot) 1457 Note:Auto-ManualselectorswitchandLocal-Remote(PLC) selectorswitchshallbeprovidedforeachAMFPanel,when selected in Auto mode, the panel shall operate through AMF relay & in manual mode, the Panel shall operate through manually, in manual mode through local-remote selector switch, in local mode panelshalloperatethroughPanelPush-Buttonandinremote mode, panel shall operate through PLC. 1458 SAFETYACCESSORIES 1459 Supply and fixing of fire extinguisher, dry chemical type 5.00 kg. Capacity(ISImark)completeswithinitialchargeandwall bracket, along with supply of all materials and labour for proper completion of work. 1460 Providing and fixing H.T. danger notice plate of 250mmX200mm, madeofmildsteel,atleast2mmthick,and vitreousenameledwhiteonbothsides,andwithinscriptionin single red colour on front side as required. 1461 Providing and fixing M.V. danger notice plate of 200mmX150mm, madeofmildsteel,atleast2mmthick,and vitreousenameledwhiteonbothsides,andwithinscriptionin single red colour on front side as required. 1462 Supply and fixing of shock treatment chart(prescribed under I.E. rules) duly framed with glass and supported from back with hard boardorsoftboardwithsupply ofallmaterial labourT&Pfor proper completion of work. 1463 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11litrescapacitydulypaintedasperfirebrigadedesign, supported on hanging bracket chained and locked, initially filled withfineriversand,waterasperdirectionsofEngineer-in- charge. 1464 Supply and layfing of 1800mmX900mmX12mm thick chequered rubber matting of tested quality. 1465 Supply and fixing of20 Wfluorescent lampoperated emergencylightwithmaintenancefreebatteryfor3hoursopeation during mains power failure. 1466 First Aid box. 1467 11 kV Rubber Hand Gloves 1468 STRUCTURE STEEL 1469 Supply&InstallationofStructureSteelrequiredforsupport structureofequipments, LCS,cable,cabletray&earthingetc. forsupportonfloor/wall/beam/bracketsetc.including required welding/ cutting/ grinding shall be done to complete the job. 1470 INSTRUMENT WORK 1471 PRESSURE MEASURMENT SYSTEM 1472 Supply, installation, testing & commissioning of 1473 Pressuretransmitterwith indicator& all accessories 1474 at delivery of each Pump and common header. 1475 Range : 0 - 10 kg / sq.cm. 1476 PRESSUREGUAGE 1477 Supply, installation, testing & commissioning of 1478 Bourdanpressureguagehaving150mmdialwith 1479 necessaryS.S.cock at delivery line of each Pump. 1480 Range : 0 - 10 kg / sq.cm. 1481 PRESSURESWITCH 1482 Supply, installation, testing & commissioning of 1483 Pressure switchat delivery line of each Pump. 1484 Range : 0 - 10 kg / sq.cm.(Adjustable type) 1485 FLOWMEASURING SYSTEM 1486 Supply,installation, testing and commissioning of 1487 Electromagnetictype flow meterwith indiactor,transmitter andtotaliserwithallaccessoriesand, 1488 hardwares, etc.complete in all respects. 1489 Size : 500 for manifold size 700 mm of R16 Header 1490 LEVEL MEASURING SYSTEM 1491 Supply, installation, testing & commissioning 1492 Ultrasonic type Level transmitter with indicator andall 1493 requiredaccessories& hardwares, etc. completein 1494 all respects. 1495 Range : 0 - 6 Mtrs.Supply, installation, testing & commissioning of Float 1496 & Board type level indicator with all accessories. 1497 Range : 0 - 6 Mtrs.Supply, installation, testing & commissioning of Float 1498 typelevelswitch withallaccessoriesforDryrun 1499 protection of pumps. Range : 0 - 10 Mtrs. 1500 FRC ANALYZERSupply, installation, testing & commissioning of Amperometrictype FreeChlorineAnalyzer complete withtransmitter,sensor,sensorcable,Sensor mountingassembly ,accessories, hardware,consumables, etc. complete in all respects.Measuring Range : 0 - 5 mg/L 1501 PLC / SCADA FOR CONTROL ROOM 1502 Supply,installation, testing and commissioning of PLC-SCADA system including Instrument control Panel,PCbasedHMIalongwith19"colourLCD Screen, Required programming/ SCADA/Application Software, A3 Size Laser Printer, GSM-GPRS / BroadbandbasedcommunicationforRemoteData Transmission,Min.1kVA UPS (with 30min backup alongwithsuitable rating SMFbatteries &battery chargerand allotheraccessoriesasperstandard), etc.completeinallrespectsandasper specifications. PLC shall have I/O count of60 DI / 24 DO / 12 AI / 0AO. 1503 INSTRUMENT CABLES 1504 Supply,laying,testingandcommissioningof Instrument Cables including termination & Trays 1505 3C X 2.5 sq.mm YWY Power cable 1506 1PX 1.5sq.mmCu.Conductor,armoured,overall& individual shieldedSignal cable 1507 2C X 1.5 sq.mmCu. Conductor,armoured ,overallshielded Control cable 1508 10CX1.5sq.mmCu.Conductor,armoured,overall shielded Control cable 1509 INSTRUMENT CABLETRAY 1510 Supplyingandinstallingfollowingsizeofperforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors,suspendedfromtheceilingwithM.S. suspenders including bolts & nuts, paintingsuspenders etc as required. 1511 100 mm width X 50 mm depth X 1.6 mm thickness 1512 200 mm width X 50 mm depth X 1.6 mm thickness 1513 CABLE END TERMINATION AND CONNECTION: 1514 Supplyingandmakingendterminationwithbrass compression gland and copper lugs for following size ofPVCinsulatedandPVCsheathedcopperconductor cable of 1.1kV gradeas required. 1515 POWER CABLE 1516 3C x 2.5 sq.mm 1517 CONTROL CABLE 1518 2C x 1.5 sq.mm 1519 10C x 1.5 sq.mm 1520 SIGNAL CABLE 1521 1P x 1.5 sq.mm. 1522 GIS MAPPING AND APPLICATION DEVELOPMENT FOR WATER SUPPLYSYSTEM 1523 Procurementof Geoeye1(>90daysarchive), standard0.5mt.resolution,multispectral8band,Color, satellite image 1524 Create and develop new vector map (1:1000 scale).IdentifythegapsinLandbaseDatafrom SatelliteImageandarrange/capturethemissing (gap) Land base features from the field etc. Includingdigitizationof geometry (line,pointand polygon) of the Land base features. 1525 Capture position on ground using DGPS with required accuracy for all land base features includingfeatures like road, divider, drainage, Bridge, Canal, Landmark, Railway Track, over ground utilities, Electric HT line etc. verification of alldigitisedfeatureswithrealgroundand create GDB (Geo- Database) using GIS 1526 Capture(setgeometrytothecorrectgeographic position in the existing data/map) all water supply pipeline network and associated line i.e. Transmission mains, Distribution main, Service line,valvechamber, scourvalve,airvalve,major pipe junctions etc. (all details required for hydraulic modelling ) positions on ground using DGPS with thedesiredaccuracy.Integrationofspatialand non-spatialdata,createGDB(Geo-Database) using GIS and Schema compatibleCreating grid of TBM with triangulation with minimum observationof2hrsformainTBMgrid and using final results of post processingsoftware output. 1527 Carryoutfiledsurveyforlatestpositionofallcivil structures related to water supply system i.e. intake structure, water treatment plant, water distributionstation,pumpingstation,overhead tank, under ground tank using DGPS with required accuracy, Integration of spatial and nonspatial data, create GDB (Geo-Database) using GIS. 1528 Digitisedrawingavailablewithclientorcreateas builtdrawingofcivil,electrical,mechanical works forintakestructure,watertreatmentplant,water distribution station, pumping station etc.and create GDB (geo database) using GIS. 1529 Capturing location of all water meter using DGPS with required accuracy ,create GDB (Geo- Database) using GIS (for revenue modelling) 1530 Application Development of water distribution management system for water supply (Schema) on GISplatform(OGCcompliance)andintegration with SCADA system scope coverintegration from staringpointtoenduserpoint(i.e.fromintake point to distribution centre, flow meter/water meter) 1531 Supply ofsoftwareArc10.2,Arcfacilitymanager and required supporting hardware (server) 1532 Labour Cess will be paid extra as per applicable 1533 GST will be paid extra as per applicable
|