Microscopes – Op Microscope. Folding Tube With Two Wide-Angle Eyepieces 10X, With Adjustable Diopters, With Integrated Magnification Changer. Apochromatic Optics, The Area Of Interest Must Be Able To Be Displayed Free Of Chromatic Aberrations. Motorized Zoom, Working Distance Adjustable To At Least 1:6, Maximum Working Distance At Least 625 Mm, Minimum Working Distance Maximum 200 Mm, The Working Distance Must Cover An Area Of At Least 425 Mm Without The Need To Exchange Or Attach Lenses. The Maximum Field Of View Must Be At Least 220 Mm. The System Must Be Able To Automatically Focus On Areas Of Interest. The Automatic Focusing Must Be Freely Selectable. The Microscope Body Must Not Exceed A Height Of 170 Mm To Enable Convenient Operation. With Interface To The Surgical Documentation System Aida. With Weight Compensation For The System, With Vibration Dampening. Motorized Xy Movement Of The Microscope Head Must Be Possible For Focusing. A Laser Focusing Aid Must Be Available For Focusing. It Must Be Possible To Automatically Extract Air From The Sterile Cover. The System Must Be Suitable For Connecting Surgical Navigation Systems. Including All Necessary Adapters And Interfaces. With Fully Integrated 3-Chip 4K Camera With A Resolution Of At Least 2160P, The System Must Have Built-In Functions For Recording Videos In 4K Resolution. With Integrated Video Recording Function, With Video Focus. The System Must Be Able To Record Videos In 3D And Still Images In 4K. Suitable For Playing Back Images And Videos On A 3D Monitor. The Integrated 3-Chip Camera Must Be Fully Operable Via The Central Touchscreen. High Performance Xenon Light Source 300 W, With Automatic Lamp Change. The Two Lamps Must Be Equivalent, I.E. H. Provide The Same Light Output. The Light Intensity Must Be Automatically Limited Depending On The Working Distance. Automatic Limitation Of The Lighting Field Depending On The Zoom Setting. When Using The Xenon Light Source, There Must Be A Warning When The Set Lighting Limit Value Is Exceeded. In The Event Of A Fault, The Change Must Be Guaranteed During Ongoing Intervention. The System Must Have A Second, Electronically Controlled Light Beam That Can Be Used To Illuminate The Areas Of The Field Of Vision That Are In Shadow. The System Must Display The Lifespan Of The Xenon Bulb And If The Bulb Is Defective. Co-Observer Device Opposite As A Stereo Bridge With 180° Swivel Tube And 2 X Eyepieces. Full Stereo View For The Main Surgeon And The Assistant. The System Must Be Prepared For Intraoperative Fluorescence Options. The Microscope Must Allow Observation Of 5-Ala Induced Fluorescence (400 Nm) During Tumor Surgery. Including All Necessary Targets. The Microscope Must Be Prepared For Visualization
Contact Information
Address
Am Finkenhügel 1
Contact No.
+49 541405-1800
Email
vergabe@klinikum-os.de
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 82967871
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.