Etender Notice No.2 (Cvts, Cath Lab) Of Rrh For 2024-25 Purchase Of Consumables And Disposables For Cvts, Cath Lab And Others For Regional Referral Hospital, Nashik For Year 2024-25 , Blood Oxygenator Membrane ? Adult & Hard-Shell Reservoir With Integrated Heat Exchanger (Polyurethane) Surface Area = 0.6M² With Membrane Surface Area 2.5 M²coating. Blood Flow Rate Of 1-60 Lit/Min, Static Priming Volume Of = 284Ml Reduced Thrombocyte Adhesion And Improvedbiocompatibility To Be Supplied With Suitable Oxygenator Holder(Sample Product To Be Demonstrated) ? Max Volume Capacity (Approx) 4500Ml ? Max Operating Level (Approx) 4000 Ml ? With Oxygenator Modules Provide Effective Gaseous Micro Emboli (Gme) Control ? Static Priming Volume Of 284 Ml ? Phosphorylcholine (Pc) Is New Generationcoating Material Designed To Ameliorate Biocompatibility ? Supplied With Suitable Oxygenator Holder , Blood Oxygenator Membrane ? Pediatric &Hardshell Reservoircapacity Of Maximum 1800Ml (Max 3Lit) - With Integrated Heat Exchanger (Stainless Steel) Surface Area Of = 0.14 M² - Indirect Continuous Micropore Channels Withmembrane Pore Size Of 0.05 Micron - Membrane Surface Area Of =1.5 M² - Biocompatible Hydrophilic Polymer Surfacecoating. - Blood Flow Rate Of 2300-2500/Min, -Totm (Trioctyltrimellilate) Plasticizer – Dehpfree. ? Cardiotomy Filter Pore Size Of 20 Microns. ? To Be Supplied With Suitable Oxygenatorholder (Sample Product To Be Demonstrated) ? Physio Coated (Physio Is Secondgeneration, Truly Biomimetic Coating Which Aimsat Improving The Haemocompatibilty Of Surfaces Incontact With Blood) ? Microporous Polypropylene Hollow Fibrematerial Membrane Surface Area 64 M2 ? Static Priming Volume (Oxymodule + He) 105 Ml · Reservoir Volume Capacity 1800 Ml · Maximum Blood Flow 2300 Ml/Min , Custom Pack Tubing Set Jipmer Circuit V - Circuit Of Pvcmedical Grade Class Tubing A (Adult) For Cardiopulmonary Bypass; Good Quality (Diagram For Jipmer Circuit V Attached)(Sample Product To Be Demonstrated / Supplied) , Custom Pack Tubing Set Jipmer Circuit V - B (Pediatric)For Cardiopulmonary Bypass; Circuit Of Pvc Medicalgrade Class Vi Tubing Good Quality (Diagram For Jipmer Circuit V Attached) -(Sample Product To Be Demonstrated / Supplied) , Hemofilters (Adult Type) For Modified Ultra Filtration : -Membrane Surface Area Of 0.68 M² -Polyether Sulfone Fibre Bundle Material - Priming Volume Of Less Than 60Ml -Pressure Drop Of 70Mm Hg - No Rinse Fiber And Internal Diameter Of 200 Microns,Molecular Weight Cut-Off Of 65,000 Dalton1/4” Tubing Setwith Male Luer Lock Ends (Sample Product To Be Supplied) - Male Pos Lock For Blood Inlet And Outlet - Ultrafiltrate Port 1/4 Connector - Maximum Blood Flow Rate 500 Ml/Min -Seiving Cut-Off = 65.000 Daltons , Hemofilters (Pediatric Type) For Modified Ultra Filtration : -Membrane Surface Area Of 0.25 M²polyether Sulfone Fibre Bundle Material -Priming Volume Is 30 Ml; -No Rinse Fiber& Material Of Polyethersulfone Fibre Bundlemolecular Weight Cut-Off Of 66,000 Dalton 1/4” Tubing Setwith Luer Lock Blood Ports -Prevention Of Thrombus Formation (Sample Product To Besupplied) - Male Pos Lock For Blood Inlet And Outlet - Ultrafiltrate Port 1/4 Connector - Maximum Blood Flow Rate 100 Ml/Min -Seiving Cut-Off = 65.000 Daltons , Arterial Filters (For Adult Circuit ) -With Bypass Loop -Priming Volume 195 Ml Maximum Blood Flow Rate Of 8 Lit /Min - Polyester Mesh Filter Size Of 40 ?M. Housing Material – Polycarbonate. Purge Line With One Way Valve. Sample Product To Be Supplied With Suitable Holder. -Physio Coating Assures High Biocompatibility , Arterial (Aortic) Perfusion Cannula Adult Type - Angledtipplain (Non-Wire Wound) Body ? Non-Vented Type - With Tip Guard With3/8 Connector; Preferably With Leur Adaptor/Connector Plug Filter, Sizes: A) 18Fb) 20F C) 22F D) 24F (Sampleproduct To Be Shown / Supplied) ? One Piece Body Adjustable Or Fixed Depthring Together With Tip And Depth Line Permitsprecise Position Of All Cannula ? Should Have Elongated One Piece Wirewound Body With Radiopaque Suture Ring Anddilator With Depth Markings , Arterial (Aortic) Perfusion Cannula Pediatric Type -Straight Tip - With Tip Guard With 1/4 Connector ?Sizes : A) 8F B) 10Fc) 12Fd) 14F E)16F (Sample Product To Be Shown / Supplied) ? One Piece Body Adjustable Or Fixed Depthring Together With Tip And Depth Line Permitsprecise Position Of All Cannula , Arterial (Aortic) Perfusion Cannula Pediatric ? Type - Angled Tip With Tip Guard With1/4 Connector; Sizes : A) 8F B) 10Fc) 12Fd)14F E) 16F (Sample Product To Be Shown /Supplied) ? One Piece Body Adjustable Or Fixed Depthring Together With Tip And Depth Line Permitsprecise Position Of All Cannula , Arterial (Aortic) Perfusion Cannula - Pediatric Type - Angled Metal Tip With 1/4 Connector ?Sizes : A) 8F B) 10Fc) 12Fd) 14F E)16F (Sample Product To Be Shown / Supplied) ? One Piece Body Adjustable Or Fixed Depthring Together With Tip And Depth Line Permitsprecise Position Of All Cannula , Heart Valve Mechanical Prosthetic Bileafiet( Position)Various Sizes ? Disc-Pyrolytic Carbon Graphite Substrate · Housing-Pyrolytic Carbon/ Titanium ·Opening Angle-85 Degree Pivot Design For Laminar Flow Rotable,Mr Compatible , Heart Valve Mechanical Prosthetic Bileafiet (Aorticposition) Various Sizes ? Disc-Pyrolytic Carbon/ Titanium ? Housing-Pyrolytic Carbon/ Titanium ?Opening Angle-85 Degree Pivot Design Forlaminar Flow Rotable,Mr Compatible , Femoral Arterial Perfusion Cannula ? Adult Type Preferably With Introducer:Sizes 14, 17 & 19F ? One Piece Body Adjustable Or Fixed Depthring Together With Tip And Depth Line Permitsprecise Position Of All Cannula , Femoral Arterial Perfusion Cannula - Pediatric Typepreferably With Introducer: Sizes 8, 10 & 12F ? One Piece Body Adjustable Or Fixed Depthring Together With Tip And Depth Line Permitsprecise Position Of All Cannula , Venous Return Cannula - Straight Type ? Multiport Tapered Tip ? Wire Wound Body Sizes: 12, 14, 16, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36 & 38 F (Sample Product To Be Shown /Supplied) ? One Piece Body Adjustable Or Fixed Depthring Together With Tip And Depth Line Permitsprecise Position Of All Cannula , Venous Return Cannula - Angled Type ? Multiport Tapered Tip & Wire Woundbody Sizes: 12, 14, 16, 18, 20, 22, 24, 26, 28 & 31F (Sample Product To Be Shown / Supplied) ? One Piece Body Adjustable Or Fixed Depthring Together With Tip And Depth Line Permitsprecise Position Of All Cannula , Venous Return Cannula Two Stage ?With Multiported Tips ?Atrial Basket ? Wirewound& Preferably Oval Body ?Depth Markings ?Sizes: 28/36, 32/40, 34/46, 36/46 &36/51F (Sample Product To Be Shown /Supplied) · One Piece Body Adjustable Or Fixed Depth Ring Together With Tip And Depth Line Permits Precise Position Of All Cannula , Femoral Venous Cannula ? Adult Type Preferably With Introducer & 3/8 Or 1/2 Inch Connector: Sizes 15, 17, 19F,21F & 23F (Overall Length Of 62 - 78Cm) ? One Piece Body Adjustable Or Fixed Depthring Together With Tip And Depth Line Permitsprecise Position Of All Cannula , Femoral Venous Cannula -Pediatric Type Preferably With Introducer &1/4 Inchconnector Sizes 8, 10, 12 & 14F (Overall Length Of 18 - 22Cm) ? One Piece Body Adjustable Or Fixed Depthring Together With Tip And Depth Line Permitsprecise Position Of All Cannula , Antegrade Cardioplegia Cannula With A Sidelimb Forvening And With Standard Tip With Side Holes Preferablyflanged ? With Introducer Needle ? Sizes: 5F, 7F, 9F & 11F (Sample Productto Be Shown / Supplied) ? One Piece Body Adjustable Or Fixed Depthring Together With Tip And Depth Line Permitsprecise Position Of All Cannula , Coronoary Ostial Cannula ? With Soft Bulb Shaped Tips With Afemale Luer Connection ? Size: 15F, 17F & 20F (Sample Product Tobe Shown / Supplied) ? One Piece Body Adjustable Or Fixed Depthring Together With Tip And Depth Line Permitsprecise Position Of All Cannula , Cardiac Suction Tube With Malleable Stainless Steel Shaft With Perforated Pooltip Of Size 10F With A Length Of Tubing & Clamp Terminatinginto A 1/4 Connector. , Tourniquet Sets (4 Tubes With One Snare) With A Quick- Tiecap Attached To One End - Lengths Of 6 &7.5. , Heart Valve Mechanical Curved Leaflets Mitral Positionvarious Sizes ?Intra Annular Seating ·Titanium Housing With Carbofilm ·Aerofil Housing ·Curved Pyrolytic Carbon Leaflets ·Dacron Sewing Ring ·Bicarbon , Heart Valve Mechanical Curved Leaflets Aortic Positionvarious Sizes ?Partially Supra Annular Seating ?Titanium Housing With Carbofilm ? Aerofil Housing ?Curved Pyrolytic Carbon Leaflets ?Dacron Sewing Ring ? Bicarbon , Bioprosthetic Valve (Bovine Pericardial) - Mitral Tissuevalves Of Various Size ? Pericardial Valve Designed For Mitralposition ? Residual Aldehydes Neutralizationtreatment ? Expected Reduction Of Calcification ? Aldehydes Free Storage Solution ? No Rinsing Required ? Anti-Looping Protection ? Clinically Proven Design ? Freedom From Svd @ 10 Years Is 100% , Bioprosthetic Valve (Bovine Pericardial) -Aortic Valves Ofvarious Size , Annuloplasty Rings For Mitral Valve(Complete Ring Type) ? Saddled Shape Complete Rigid Ring -Lower Profile For Ease Of Implant -Rigid Various Sizes , Annuloplasty Rings For Mitral Valve - Semi Rigid Complete Ring (Rigid Posteriorly And Flexibleinteriorly) - Lower Profile For Ease Of Implant - Flexible Various Sizes , Annuloplasty Rings For Tricuspid Valve Anatomicallyshaped 3 Dimensional Rigid Ring - Incomplete Ring To Avoid Interference With The Heartsconduction System -Size: 26, 28, 30, 32, 34 & 36 Mm , Cardiac Tissue Stabilization System For Beating Heartsurgery (Suction Based-Octopus Type) Suitable Withstandard Retractors Complete Set · Low Profile Head Link · Automatic Pod Spread ·Longer Articulating Arm , Cardiac Tissue Stabilization System For Cardiac Apex : Forbeating Heart Surgery (Suction Based- Starfish Type) , Coronary Shunts (Silicon)-Sizes 1Mm, 1.5Mm, 2Mm,2.5Mm For Intra-Operative Use For Cabg (Coronary Arterybypass Graft) , Disposable Aortic Vascular Punch – Sizes: 3Mm, 3.5Mm,4Mm, 4.4 Mm & 5Mm , Disposable Bull Dog Type Vascular Clamp Small Andmedium For Coronary Work (Sample Product To Be Shown /Supplied) , Arterial Embolectomy Catheter Sizes 3F, 5F And 7 F Of 80Cm Long And 2F Of 60 Cm Long With Wall-Mount Catheterrack. , Femoral Puncture Needle18g,20G , Y-Connector 2 Way( Push/Pull )Ptca Needle Torqure , Disposable Chest Drainage ( Underwater Seal) ? Bottles With 1.5 – 2 Lit Capacity Withfacility For Suction And Patient Connection Tubewith Step Type Connector (Sample To Be Supplied) ? Made From Non-Toxic Medical Grade Pvctubing ? Distal End Is Open With Super Smoothcross Side Large Eyes To Maximize Drainage Fromthe Chest ? Specially Designed Tapered Tongue Fixedat Proximal End To Provide Excellent Forceps Gripfor Atraumatic Passage Through Tissue ? Catheters Are Marked At 2 Cm From Thelast Eye To Ascertain The Depth Of Placement Withradio Opaque Line ? Eto Sterile And Pyrogen Free , Sterile Incision Surgical Drape ? Size:(Sticking Surface) 60X45 Cm, Selfadhesive ? (Sample Product To Be Supplied) , Disposable Suction Tubing (For Connection To The Suctiontip With Handles 0.5 Meters Length , Disposable Pressure Monitoring Kit (With Transducer, Flushdevice For 3Ml/Hr @ 300 Mm Hg, Extension Lines) ? Suitable To Be Connected To Datexohmeda Multiparameter Monitor - One Pressure Monitoring Cable To Be Supplied For Every 25 Kits. , Pressure Infusion Bags 1 Lit Capacity Heavy Duty Withpressure Monitoring Facility , Pressure Infusion Bags 500 Ml Capacity Heavy Duty Withpressure Monitoring Facility , Arterial Pressure Monitoring Extension Line Male – Male150 Cm Long Straight / Spiral Type - (Sample Product To Besupplied/ Demonstrated) , Intra Venous Cannula Without Injection Port 35 & 51 Mmlong, Size 20G (Sample Product To Be Supplied) , Intra Venous Cannula Without Injection Port 35 & 51 Mmlong, Size 22G (Sample Product To Be Supplied) , Long Peripheral Venous Catheter (For Central Venousinfusion) Of Various Sizes (Sample Product To Be Supplied) , In-Dwelling Arterial Catheter Preferably With Self Adapter - Various Sizes (Sample Product To Be Supplied) , Medical Grade Pvc Snuggers(Adult &Pediatric) For Pursestring Sutures , Ecg Electrode ?Prejelled (Sample Product To Besupplied) , Intra Aortic Balloon 30Cc & 35Cc ?Intra Aortic Balloon Should Be Able To Getconnected To The Arrow Iabp Model Acat-1 Plusmachine ? The Balloon Should Come With Allaccessories Like Introducer With Sideport, Guidewire And Introducer Sheath ? Should Be Compatible For 7Fr Catheter ? V-Hub Technology ? Compatible For Existing Machines , Intra Aortic Balloon 40Cc ?Intra Aortic Balloon Should Be Able To Getconnected To The Arrow Iabp Model Acat-1 Plusmachine ? The Balloon Should Come With Allaccessories Like Introducer With Sideport, Guidewire And Introducer Sheath ? Should Be Compatible For 7Fr Catheter ? V-Hub Technology ? Compatible For Existing Machines , Cardio Plegia Needle (With Protection Systems With Ll -Female Connection)Size:- 16G/14G , Vent Cathater Size 12 Fr /14Fr , Outer Dia- 4.0Mmperforation - 36Mm,14Fr- Outer Dia- 4.6Mm Perforation -36Mm Maleabale Light House Tip With Stylet , Blood Cardioplegia Delivery System (Kole Chamber) Adult Disposable ? Gentle Mixing Of Crystalloid & Blood ? Low Contact Area ? Smooth Surface Yet Fast Cooling ? Elimination Of Air Bubbles , Blood Cardioplegia Delivery System (Kole Chamber) Paed Disposable ? Gentle Mixing Of Crystalloid & Blood ? Low Contact Area ? Smooth Surface Yet Fast Cooling ? Elimination Of Air Bubbles , Blood Cardioplegia Delivery System (Kole Chamber) Adultreusable ? Gentle Mixing Of Crystalloid & Blood ? Low Contact Area ? Smooth Surface Yet Fast Cooling ? Elimination Of Air Bubbles , Blood Cardioplegia Delivery System (Kole Chamber) Paedreusable ? Gentle Mixing Of Crystalloid & Blood ? Low Contact Area ? Smooth Surface Yet Fast Cooling ? Elimination Of Air Bubbles , Ventilator Tubing With Hme 4 Meter Length , Sternal Wires Size 20,22,24 , Dacron Sauvage Filamentous Patch 4*4 , Thoracic Drainage Catheter ? Size 24,28,32 ? Made From Non-Toxic Grade Pvc Tubing ? Distal End Is Open With Super Smoothcross Side Large Eyes To Maximize Drainage Fromthe Chest ? Specially Designed Tapered Tongue Fixedat Proximal End To Provide Excellent Forceps Gripfor Atraumatic Passage Through Tissue ? Catheters Are Marked At 2 Cm From The Last Eye To Ascertain The Depth Of Placement With Radio Opaque Line · Eto Sterile And Pyrogen Free , A.C.T. Cartridges (Celite&Kaoline Act Tubes ) 50*2 , Disposable Cardioplegia Delivery System ? It Has Low Priming Volume Of 30 Mlefficient Heat Exchanger ? It Cools And Mixes The Cardioplegia ? Blood Line 1/4 Id And Cardioplegia Line3/8 Id With Bridge That Enables To Perfusionist Todo Systematic Blood Perfusion ? It Has Bubble Trap For Easy And Bubblefree Priming , Non-Traumatic Gloves Sterile With Gama Rays All Sizes , Icd Bottle 2Ltr , Heart Valve Prosthesis Aortic Bovine Pericardial Varioussizes ?Bovine Pericardial Valve ?Tap Around With Linxanticalcification , Heart Valve Prosthesis Mitral Bovine Pericardial Varioussizes ?Bovine Pericardial Valve ?Tap Around With Linxanticalcification , Zebra Wire 0.035, 0.025, 0.018 , Biopsy Forecep , Central Venous Catheter ? Dilator, Saclpel #11-Short (Optional), 035Guidewire J Tip Which Is Flexible For Ease Ofinsertion, 5Cc Syringe With Luer Lock Providesecure Connection To Needle., ? Needle 18Ga X 2-3/4.3-Lumen Cvp Cath4.0 Fr 7 Cms 20,22,22 0.018 X 45 Cms , Double J Stents Set ? Thin Wall Design For Maximum Drainage ? Smooth Surface For Easy Insertion Type=Open End. Closed End. One End Multi Loop. Bothend Multi Loop ·Sizes= 3.0 Fr To 8.0 Fr ·Length-8 Cm To 32 Cm , Urethral Stent ?Smooth Surface Being Less Traumatic. ?Soft Polyurethane Material For Patientcomfort ?Highly Radiopaque For Better Visualization ?Tapered End - For Easy Insertion ?Type= Open End. Closed End ?Sizes= 6 Fr To 16 Fr ? Length= 25 Cm , Pcn Catheter Without Needle ? Soft And Flexible Material For Patientscomfort ?Pcn Catheter Without Needle. ?Sizes= Pcn Catheter 10Fr, 12Fr, 14 Fr,Pcn Catheter With Needle. 6 Fr To 14 Fr ? Length= 30 Cm. , Pcn Drainage Set ? Available In Polyurethane & Eva ? Soft And Flexible Material For Patientscomfort ? Classification= Pcn Set With Pigtail / Jshape Catheter. Pcn Set With Malecot Catheter. , Suprapubic / Malecot Catheter ? Type= Normal Malecot. Suprapubiccatheter ? Sizes= Malecot Catheter 8Fr To 26 Fr.Suprapubic Catheter 8 Fr To 18 Fr. ? Length= 20 Cm To 40 Cm. , Re-Entry Malecot Catheter ? Highly Radiopaque For Bettervisualization. ? Smooth Surfaces For Ease Of Introduction. ? Uniform Taper To Reduce Trauma. ? Size= 8/4 Fr, 10/5 Fr, 12/5 Fr, 14/6 Fr,16/7 Fr, 18/7 Fr, 20/8 Fr. Length= 30 Cm To 48Cm. , Fascial Dilator Set & Single Urethral Dilator Set ? Smooth Surfaces For Ease Ofintroduction. ? Uniform Taper To Reduce Trauma. ? Size=6 Fr To 16 Fr. Length= 22 Cm. , Urethral Dilator Set & Single · Smooth Surfaces For Ease Of Introduction ·Uniform Taper To Reduce Trauma · Colours= Blue/Gray/Green · Material= P.U & Eva · Size= 6 Fr To 16 Fr. Length= 70 Cm. , Urethral Dilator Set & Single Smooth Surfaces For Ease Of Introduction. ? Special Atraumatic Design. ? Size= 8 Fr To 22 Fr. Length = 40 Cm. , Metal Dilator Male/ Female. ? Smooth Surface For Ease Of Introduction. ? Special Atraumatic Design. ?Size= 6-16 Fr, L=9 Cm. , Filiform Urethral Dilator ?Smooth Surface For Ease Of Introduction. ? Uniform Taper To Reduce Trauma. ?Type= With Hole. Without Hole, Curved. ?Size= 6 Fr To 22 Fr. ?Length= 10 Cm To 30 Cm. , Screw Dilator ?One Step Dilation-Time Saving. ? Smooth Surface For Ease Of Introduction. ?Colour= Blue/Green. ?Size= 6/12 Fr , 6/10 Fr, 14 Fr. ? Length= 22 Cm. , Urethral Balloon Dilator ? Short Tapered Distal Tip Allows Closeapproach To Urethral Stone. ?Sizes= Balloon Width= 10Mm, ?Balloon Length= 20,40,60Mm, ? Dialator Length= 40Cms. ? Shaft Size= 4.8 Fr. , Stone Basket Four And Five Wire Configurations Are Available. ?Adjustable Knob Allows For Controlledand Assured Basket Expansion. ?Handle Permits Complete Disassembly. ? Type=Helical, Segura. ?Size= 3 Fr To 5Fr. Length= 70 Cm To 130Cm. , Stone Grasper Tri Prong Atraumatic Forceps. ?Maximum Grasping Efficiency. ?Type= Flexible. Rigid. ?Sizes= 3-4 Fr. Length= 90 Cm , Liga Clip 102 With Free Applicator , Liga Clip 200 With Free Applicator , Biopsy Gun , Lead Apron With Hanger , Nitrile Examination Gloves All Sizes ( Blue, Light Purple,White) , Ptca Guide Wire Torquer ? Should Hold Guide Wires From 0.009- 0.018 Inches ? Ergometric And User Friendly Design , Monifold With Attached Tubings ? Two Side Port Manifold One Connector Tubing For Connecting Manifoldtuohy Borst ? One Luer Lock Control Syringe (10 Or 12Ml) For Contrast Injection ? One Large Bore Tubing (With Flowregulating Knob) For Withdrawing Contrast ? One Three Way Stop-Cock , Ptca Guide Wire ?Regular Length ,Durasteel Material 0.014’ Diameter 190 Cm Length, Full Polimer Cover, Extra Support Shaft Andfloppy Tip, Tip Load, 0.8,1.2,1.0 , Ptca Guide Wire ? Regular Length , Regular Shaft Supportand Floppy Tip, Nitinol Material With Intermediate Polymer Sleeve , 0.014’ Diameter 190 Cm Length, 0.6 & 0.8 , Ptca Guide Wire ? Hydrophilic Coated Regular Length, 0.014’ Diameter 190 Cm Length, Durasteel Material With Core To Tip Design, Hydrophilic Coating, Transitionless Core Grind, Tip Load 0.9 , Ptca Guide Wire ? Hydrophilic Coated Exchange Length, 0.014’ Diameter 190 Cm Length. Durasteel Core Material, Full Polymer Cover, Marker Band, 0.014’ Diameter 190 Cm Length, Tip Load 2.7,0.8,4.1Gm , Special Ptca Guide Wire With Dual Coating ? Should Have Distal Hydrophilic Coatingand Proximal Hydrophobic Coating ? Should Have Wires With Variable Tip Stiffness And Variable Shaft Support , Special Ptca Guide ? Special Ptca Guide Wire With Multiplemarkers For Measuring The Length Of Stenoticsegment , Ptca Guide Wires For Chronic Total Occlusion(Cto) Special Non-Tapering Ptca Guide Wires Forcto With Platinum Iridium Distal Spring Coil ? Wires Availablwe In Variable Distal Tip,Stiffness Measured In Terms Of Grams , Special Tapering Ptca Guide Wires For Cto Withplatinum Iridium Distal Spring Coil ? Wires Available In Distal Variable Tipstiffness , Special Hydrophilic Ptca Guide Wires For Cto Withsuper Elastic Alloy ( Ni-Ti) Core ?Polyurethrane Hydrophilic Distal Coating, Tapered Coil From 0.014” To 0.010” Disatl 3 Cm Tip Load,1.7 Gm , Special Large Ptca Balloons Of More Than 4 Mm ? Variable Lengths , Speclal Ptca Balloon Catheter With Low Crossingprofile ?Must Have Crossing Balloon Profile Of Lessthan 0.025 Inches ? Sould Be Available In Variable Balloonlengths , Special Deb Ptca Balloon ?Paclitaxel Uniform Dose, With Fast Exchange Ptca Balloon Catheter Tip Entery Profile Of 0.017” With Platinum Iridium Markers, Tri Folded Balloon With Special Drug Coating Technology , Special Ptca Balloon Ptca Balloon For Retrograde Approach Of Cto ? Should Have Large Immediate And Longterm Data Of Safety And Efficacy Presented In Peerreviewed Scientific Journals And Reputedconferences ? Cto Approved Letter Compulsory With Availability Of Sc And Nc Balloons In Same , Cutting Balloon For Ptca Having Micro-Surgicalatherotomes(Blades) ? Should Have Large Immediate And Longterm Data Of Safety And Efficacy Presented In Peer Reviewed Journals And Reputed Conferences , Covered Coronary Stents ? Should Be Available In Different Sizes ? Latest Modification Must Be Coated , Sirolimus Coated Drug Eluting Coronary Stents ? A Premounted Cobalt Chromium Alloystent With A Drug Coating Of Sirolimus. ?Premounted On Monorail Balloon. ? Should Have Ultra Thin Struts For Optimumflexibility. ? Should Be Available In Various Sizes Andlength. ? 5F Compatible. ? Excellent Traceability And Pushability. ? Should Have Large Immediate Andshedata Of Safety And Efficacy Presented In Peer-Reviewed Scientific Journals And Reputed 10 Yearsdata With Safety And Efficacy Tested In Reputedtrial. ? Latest Modification Of The Product Should ? Be Quoted. ? Polymer Free Stent With Probucol As Drugcarrier , Everolimus Coated Drug Eluting Coronarystents ? A Premounted Cobalt Chromium Alloystent With A Drug Coating Of Everolimus.Multi Link 3-3-3 ?Premounted On Monorail Balloon. ? Should Have 81 Micron Struts For Optimumflexibility. And With Fluropolymer ? Should Be Available In Various Sizes Andlength. ? 5F Compatible. ? Excellent Traceability And Pushability. ? Should Have Large Immediate And Longterm Data Of Safety And Efficacy Presented Inpeer-Reviewed Scientific Journals And Reputedconferences. ? Latest Modification Of The Product Shouldbe Quoted. ? Long Term Data Up To 10Years , Pressure Wire For Ptca Ffr Catheters Should Be Compatible With Volcano Ivus S5, St Jude System , Special Micro-Catheter For Cto Retrograde Approach , Iabp Catheter With Accessories Should Be Compatible With Existing Machine , Thrombectom Y Catheters With Manual Suctionduring Ptca ? Aspiration Catheter Should Have Largerlumen For Aspirating Thrombus ? 6F Guide Catheter Compatible ? Dual Lumen Monorail Design ? Should Have Large Immediate And Longterm Data Of Safety And Efficacy Presented Inpeer-Reviewed Scientific Journals And Reputedconferences , Other Catheters For Pci Embolic Protection Devicesbased On Filter Technology Mechanismembolic Protection Devices With Distal Balloon Occlusive Technology , Embolic Protection Devices With Proximalballoon Occlusive Technology , Coronary Micro-Catheter ?6 Fr (Proximal Shaft) Tapered To 1.8 Fr.(Distal Shaft) With Length Of 130 Cm And 150 Cmlong ? Having Marker At The Distal Tip ? Ptfe Inner Layer For Smooth Guide Wirehandling With Less Resistance Even When Thecatheter Is In A Tortuous Vessel ? Over The Wire System ? 6 F Access Compatible , Compression Devices For Radial Artery A) Compression Devies For Radial Artery-Balloonbasedcompression , Balloon Catherers; Low Profile Balloon Dilationvalvuloplast Ycatheter ( For Pediatric & Adultuse) , Low Profile Balloon Dilation Valvuloplast Ycatheter ( For Infants & Neonatal Use) , High Pressure Balloon Dilatation Valvuloplast Ycatheter ( For Pediatric And Adult Usr) , Intra Aortic Balloon , Asd Sizing Balloon Catheter (Dynamic Circular) ? Round Balloon Catheters ? Catheter Length 65- 100 Cm ? Maximum Inflated Balloon Diameter Inmm Should Be 20, 27, 33, 40 ? Recommended Introducer Sheath Size Upto 14 F ? 0.035 Inch Compatible Catheter , Asd Sizing Balloon (Stop Flow) ? Designed To Measure Cardiovascularstructures ? Stop Flow Sizing Of Atrial Septal Defectsto Determine Appropriate Occluder Size For Thedefect ? Varying Sizes 18 Mm Onward , Mitral Valvotomy Balloon ? The Balloon Should Have Materialconstruction Such That It Inflates To A Dumbbellshape In A 3 Step Procedure First Distal Thenproximal And Finally The Waist To Relieve Mitralvalve Stenosis ? The Balloon Must Have Two Safety Ventholes In The Outer Layer To Allow The Trappedcontrast Medium To Slowly Escape And Deflate Theballoon, In Case Of Deflation Failure ? Balloon Required In Sizes Of 20 Mm, 22Mm, 24 Mm, 26Mm, 28 Mm & 30 Mm. All Sizesmust Be Available For Purchase ?Accessories Required (Standard) With Thebmv Balloon: Stretching Tube, Dilator,Guide Wire(0.025/175 Cm) Stylet (0.38/80 Cm) And Caliper , Musculat Vsd Device For Post-Infarct Defect , Pediatric Catheters & Sheaths; Pigtail Catheterwith Markers , Long Introducer Sheath ( 20-30 Cm Long) (Size 12Fr And Higher) , Long Introducer Sheath ( 20-50 Cm Long) (Size 5Fr -9Fr) , Long Introducer Sheath ( 30-50Cm Long ) ( Size 10Fr-11Fr) , Long Introducer Sheath ( 30-50Cm Long ) ( Size 12Fr And Higher) , Extra Long Introducer Sheath ( >50 Cm)(Size 5 Fr-9Fr) , Extra Long Introducer Sheath ( >50 Cm)(Size 10 Fr-11Fr) , Extra Long Introducer Sheath ( >50 Cm) (Size 12Fr Higher) , Nih Catheter , Multiple Purpose End Hole Catheter , Multitack Angiographic Catheter; , 108 Wire Regular Lengrh, Reculat Shaft Stiffness , Wire 0.018 Exchange Length Regular Shaftstiffness , Super Stiff Guidewires , Embolization (Free, Non-Detchable Coils) , Vascular Occlusion Plug With Compatible Delivery System ? Made Of Biologically Inert Material ? Self Expanding ? Can Be Recaptured And Repositioned ? Good Memory ? Radio Opaque ? Less Chances Of Embolisation ? Available In Size 4-20 Mm , Permanent Pacemakers With Vvi ?All Single Chamber Modes And Basicpacing Programmable Parameters ?The Size Of Lead Must Be 7F Or Less ?The Lead Must Be Steroid Eluting Andshould Be Both Bipolar And Unipolarconfiguration ?Must Have Both Active And Passivefixation Endocardial Leads Available ?Life Term Replacement Warranty ?Direct Presence Of Parent Company Inindia (Not Only Through Distributors) Andcompany Must Provide Its Trained Technicalperson For Each Implatation Wheneverrequired And For Follow Up Programmingwhen It Is Required ?Company Must Provide At Least Oneprogrammer Exclusicely To The Cardiologydepartment ?Company Must Quote Only The Latestmodel Of Devices Commercially Available , Permanent Pacemakers With Ssir ? All Single Chamber Modes And And Basicpacing Programmable Parameters ? Must Have Ventricular Capturemanagement ? The Size Of Lead Must Be 7 F Or Less ? The Lead Must Be Steroid Eluting Andshould Be Both Bipolar And Unipolar Configuration ? Must Have Both Active And Passivefixation Endocardial Leads Available ? Life Term Replacement Warranty ? Direct Presence Of Parent Company Inindia (Not Only Through Distributors) And Companymust Provide Its Trained Technical Person For Each Implatation Whenever Required And For Follow Up Programming When It Is Required · Company Must Provide At Least One Programmer Exclusicely To The Cardiology Department · Company Must Quote Only The Latest Model Of Devices Commercially Available , Icd With All Leads All Accessories ? Single Chamber ? All Basic Programmable Parameters ? Leads Should Be Steroid Eluting ? Should Have Both Active And Passivefixation Leads ? Minimum 5 Year Replacement Warranty ? Direct Presence Of Parent Company Inindia (Not Only Through Distributors) Companymust Provide Its Trained Technical Person For Eachimplatation Whenever Required And For Follow Upprogramming When It Is Required ? Company Must Provide At Least Oneprogrammer Exclusively To The Cardiologydepartment ? Company Must Quote Only The Latestmodel Of Devices Commercially Available , Icd With All Leads All Accessories ? Single Chamber ? All Basic Programmable Parameters ? Must Have Facility Of Atp Charging Fordefibrillation ? Leads Should Be Steroid Eluting ? Should Have Both Active And Passivefixation Leads ? Minimum 5 Year Replacement Warranty ? Direct Presence Of Parent Company Inindia (Not Only Through Distributors) Companymust Provide Its Trained Technical Person For Eachimplantation Whenever Required And For Follow Upprogramming When It Is Required ? Company Must Provide At Least Oneprogrammer Exclusively To The Cardiologydepartment ? Company Must Quote Only The Latestmodel Of Devices Commercially Available , Icd With All Leads All Accessories; Dual Chamber ? All Basic Programmable Parameters ? Leads Should Be Steroid Eluting ? Should Have Both Active And Passive Fixation Leads · Minimum 5 Year Replacement Warranty · Direct Presence Of Parent Company In India (Not Only Through Distributors) Company Must Provide Its Trained Technical Person For Each Implantation Whenever Required And For Follow Up Programming When It Is Required Company Must Provide At Least One Programmer Exclusively To The Cardiology Department · Company Must Quote Only The Latest · Model Of Devices Commercially Available , Temporary Pacing Leads , Long Sheaths Introducers , Indifferent Electrode +Cable Set , Ecg Tip Pin Electrode , Haemostatic Dressing , Valve Aortic Bovine Pericardium Without Pericardialcovering Stent ? Supra-Intra Annular Positioning Foradaptability To Diverse Anatomies ? The Lowest Profile Tissue Valve Forclearance Of Coronary Ostia And Sino- Tubularjunction ? Flexible Stent ? Radiographic Markers For Sharp X-Ray ? Imaging ? Low Friction Sewing Cuff For Soft Sutureplacement , Intra Aortic Balloon 35 Cc ?Intra Aortic Balloon Should Be Able To Getconnected To The Arrow Iabp Model Acat-1 Plusmachine · Should Be Compatible For 7Fr Catheter · V-Hub Technology · Compatible For Existing Machines · The Balloon Should Come With All Accessories Like Introducer With Sideport, Guide Wire And Introducer Sheath , Bypass Belt (Open Heart Surgery) ? 50 Mm Thick Puf Pad Hold And Binds Thefractured Sternum Without Compromising Onpatient Comfort ? Facilitates Phlegm Expulsion After Cardiothoracic Surgery ? Strong Elastic Band Gives Good Grip Andhelps In Equidistribution Of Pressure ? Reduces Post Operative Pain Anddiscomfiture , One Piece Pediatric Cannula Sizes : 6 Fr – 16 Fr Vented Andnon Vented ? Should Be Beveled, Thin Wall Tips Withelongated, One Piece , 45 Angled Tip Arterial Cannula Sizes : 18 Fr – 24 Fr ? Should Be Beveled, Thin Wall Tipsattached To Tapered Cannula Bodies ? Should Be Available In Pediatric And Adultsizes , Arterial Cannula 45 Angle With Diffused Flow Tip Sizes : 18Fr – 24 Fr ? Should Be One Piece Wire Wound Bodywith Integrated Flutes For Diffused Flow. , Femoral One Piece Arterial And Venous Cannula Kit Sizes8-21 Fr Arterial And 8-29 Fr Venous ? Should Be One Piece Wire Wound Body. , Femoral Multistage Venous Cannula Sizes : 29/29/29 Frand 29/46/37 Fr ? Should Be One Piece Wire Wound Multipleside Holes Body With Percutaneous Kit. , Standard Insertion Kit ?Kit For Femoral Cannulation , Straight Tip Arch Cannula Sizes : 8 Fr – 24 Fr Vented Andnon Vented Pediatric And Adult ? Should Be Beveled, Thin Wall Tipsattached To Tapered Cannula Bodies · Should Be Available In Pediatric And Adult Sizes , Carpentier Bi-Caval Femoral Venous Cannula Sizes : 24/29Fr, 30/33Fr ? Should Have Wire Wound Kink Resistanttwo Stage Design. , Single Stage Venous Cannula With Metal Tip Sizes : 12-31Fr ? Should Have Kink Resistant Wire Woundtaper Body With Beveled Metal Tip. , Single Stage Venous Cannula With Right Angle Sizes : 12 -40 Fr ? Should Have Kink Resistant Wire Woundtaper Body With Tapered Multiport Tips. Rightangle With Plastic Tip , Single Stage Straight Venous Cannula Sizes 12 - 40 Fr ? Should Have Kink Resistant Wire Woundtaper Body With Tapered Multiport Tips. , Single Stage Straight Venous Cannula Malleable Sizes : 12 - 40 Fr ? Should Have Kink Resistant Malleable Wirewound Taper Body With Tapered Multiport Tips , Double Stage Venous Cannula Round And Oval Shapesizes : 28/36 , 36/46,32/40 , 34/46, 36/51 ,32/40, 36/46 Fr ? Should Be Two Stage Cannula With Ovalbody In Various Sizes ? Should Be Two Stage Cannula With Roundbody In Various Sizes ? Should Have Cannula Body With Thinwalled With Depth Markings. , Three Stage Venous Cannula Sizes : 29/29/29 Fr And29/46/37 Fr ? Should Be Three Stage Venous Cannulafor Vavd/Kavd , Ultra Flex (Multiple Stage) Venous Cannula Sizes : 23 Frand 29 Fr ? Should Have Polyurethane Wire Woundbody With Radiopaque Markers And Multiple Holesat Distal End. , Aortic Root Cannula Sizes : 4 Fr – 11 Fr · Should Have Radiopaque Tips Attached To Clear Pvc Bodies · A Root Pressure Monitoring And Left Heart Venting ·Can Be Used To Aspirate Air Emboli As Well Administer Cardioplegia , Aortic Root Cannula With Vent Line Sizes : 5 Fr – 11 Fr ? Should Have Radiopaque Tips Attached Toclear Bodies With Separate Vent Line. , Aortic Root Cannula Pediatric, Neonatal Sizes : 4 Fr ? Should Be Able To Aspirate Air From Aorta ? Should Have Radiopaque Tip And Standard 5.5 In Length Or A Shortened 2.5 In , Silicon Ostial Cannula For Continuous Perfusion Sizes : 15Fr , 17 Fr And 20 Fr ? Should Have A Silicon Bodies With Softbulb Shaped Tips ? Should Have A Female Luer Connectionsite , Ostial Perfusion Cannula With Basket Tip And Soft Convextip Sizes : 10 Fr , 12 Fr And 14 Fr ? Should Have Flanged, Radiopaque Baskettips/Soft Tips Attached To Malleable Stainless Steelshafts , High Flow Coronary Ostial Cannula Sizes : 10 Fr , 12 Fr And14 Fr ? Should Have Radiopaque Basket Tip Withlarge Bore Steel Shafts. , Minimally Invasive Aortic Root Cannula With 31 Cm Length ? Should Have 31 Cm Long Body To Allowinsertion During Mics. , Minimally Invasive Retrograde Cardioplegia Cannula Withdeflecting Tip Sizes : 13 Fr And 15 Fr Should Have Tip Deflecting Models For Sinusplacement Through Thoracotomy ? Should Be Able To Allow 10Mm Sweep.Auto/ Manual Inflatable , Retrograde Cardioplegia Cannula With Manual Inflate Withguide Wire Stylet, Adult And Pediatricsizes : 13 Fr And 15Fr ? Should Have Silicon Bodies And Manual Inflate Cuffs · Should Have Pressure Monitoring Lines ·Should Be With Smooth Cuff And A Syringe For Cuff Inflation. , Retrograde Cardioplegia Cannula With Auto Inflate Sizes :13 Fr And 15 Fr ? Should Have Silicon/Pvc Bodies With Autoinflate Cuff With Pm Lines ?Should Have Multiport Tip/ Integralstopcock. , Multiple Perfusion Set ? Should Be Able To Allow Simultaneousperfusion Of The Aortic Root And Up To Three Ormore Vein Grafts ? Should Have Inlet Ports With Male Orfemale Lures And Clamps Attached To An Adapterthat Splits Into Four Or More Legs , Distal Perfusion Kit ? Should Be Able To Perform Simultaneousperfusion Of Aortic Root And Upto 3 Or More Veingraft. , Left Heart Vent Catheters Sizes :10 Fr , 13 Fr , 15 Fr , 16 Fr ,18 Fr , 20 Fr , 24 Fr ? Should Be Of Pvr Or Silicon, Could Beused For Direct And Indirect Venting, Should Haveperforated Tip, Malleable Bodies With Depth Mark ? Should Have A Choice Of Either Pvc Orsilicone, Along With Straight Body With Depthmarking ? Should Have All Vent Terminate With Avented Or Non - Vented 1/4 In Connector. , Pericardial Sumps Sizes : 20 Fr ? Should Feature A Fluted Tip ? Should Encased In A Stainless Steel Springand Should Have Weight At The End , Intracardiac Sump Sizes : 20 Fr ? Should Feature A Perforated Pool Tip Tomaximize Suction And Minimize Tissue Trauma. ? The Tip Design Should Be Ideal Foratraumatic Suction Within The Heart Chambers , Suction Tubes Sizes : 6 Fr , 10 Fr And 20 Fr ? Should Have Variety Of Cardiac Suctiontubes, Intracardiac Suction Tubes & Rigid Suctiontubes. , Micro Suction Tubes Sizes : 9 Fr ? Should Have A Vacuum Control Port,Malleable Shaft ? Should Be Equipped With A Length Oftubing And Clamp Terminating With A 1/4 In(0.64Cm) Connector. , Macro Rigid Suction Tubes Sizes : 20 Fr ? Should Have Tip Made Up Of Stainlesssteel ?Should Have Fluted Pool Tip To Maximizesuction And Minimize Tissue Trauma ? Should Offer Gentle Suction. , Tourniquet Sets Sizes : 12 Fr , 16 Fr And 19 Fr ? Should Have Colorcodedtubes Withvarying Lengths For Adults And Pediatric ? Should Have Wire Snares Included Withthe Tube Set , Coronary Artery Retraction Clips Sizes : 3 Mm And 5 Mm ? Should Be Designed To Improve Exposureto A Coronary Anastomosis Site ? Should Be Able To Small Prongs Andgently Hold Tissues Away From The Vessel Toimprove Vision. , Rapid Priming Set Length : 35.6 Cm And 40.6 Cm ? These Should Facilitate The Transfer Offluid During The Priming Of The Circuit. ? Should Have Large Bore Spikes Attachedto Flexible Tubing With A Clamp. ? Should Terminate With Either An Openend Tube Or A Male Luer , Rapid Priming Y Set Length : 1.1 M ? These Should Facilitate The Transfer Offluid During The Priming Of The Circuit. ? Should Have Large Bore Spikes Attachedto Flexible Tubing With A Clamp. Should Attach To A Y Adapter With A Length Oftubing And Another Clamp , Bacterial /Viral Filter , Hme Filter , Eto Roll -15Cm X 200M , Eto Roll -25Cm X 200M , Eto Roll -30Cm X 200M , Helium Cylinder For Iabp Machine (Reffiling Charges) , Custom Tubing Pack (Heart -Lung Pack)-Adult , Briziooxinator Membrane Coated With Filter (Adult)-Nipro , Blood Collection Bag Single. , Dialyzer F6 -Heam -O-Flux (Polymed) , Dialyzer F8 , Av Fistula Needle - No.17 , Heamodialysis Catheter Kit Triple Lumen -12Fr Curved 13Cm , Heamodialysis Catheter Kit Triple Lumen - 11.5Fr Curved , Absorbable Gelatin Sponge , Central Venous Catheter Kit , Digital X-Ray Film 8X10 (Pack Of 100 Films) - Agfa , Digital X-Ray Film 10X12 (Pack Of 100 Films) - Agfa , C.T. Scan Film 14 In. X 17 In. (Dt2b Dry Star) (Pack Of 100 Films) -Agfa , Haemosec Titanium Clip Small - Yellow (Box Of 24Cartridge) , Sterispon Absorbable Gelatin Sponge Usp 80X50x10mm , Disposable Sterile Skin Stapler (Dt35w) , Eto Cartriage 170Gm , Diasafe Filter , Dialyzer F6 , Blood Tubing Set For Haemodialysis , A.V Fistula Needle Size 16-G , Protect Plus,Protection Kit , Triple Composition Aortic Prosthesis Various Sizes ? Prcine Heart Valve ?8-9Mm Profile ?Sewing Ring With Markers ? Linx Anti Calcification , Triple Composition Mitral Prosthesis (Bio) Various Sizes ? Prcine Heart Valve ?Low Profile (9Mm) ?Sewing Ring With Markers ? Linx Anti Calcification , Radial Sheath 5 F , 6 F7 Cm ,0.025 Cm , 20 G(Terimo ) , Radial Catheter 5 F /6 F0.038 (0.97 Mm ) _100 Cm (Terimo) , Diagnostic Catheterjr/Jl/Pigtail /Ar/Al/Ntr5f/6F , Angiography Guide Wire (Ptfe Coat) 0.035 X 150 Cm Jtip 0.032 X 150 Cm Jtip 0.035 X 260 Cm Jtip , Terumo Guide Wire 0.035 X 150 Cm Jtip 0.035 X 260 Cm Jtip , Inflation Device Kit , Introducer Sheath 6 F/ 7 F 11 Cm , Guiding Catheter 6F,7F,5Febu ,3.0/3.5/4.0 Ar-I Iijr 3.0 X 3.5 /4.0Al –Ii Jl 3.0/3.5/4.0Rbl -4.0 , Pressure Line 200 Cm (Male /Female Luer Lock) , Ptca Guide Wire Double Core Desin Stainless Steel & Digital Nitin, Jtip 0.14,190 Cm /300 Cm Soft /Medium /Hydrophilic Coating , Ptct Guide Wire Cto Wire , Aspiration Catheter (Tharmbostev) 5F/6F100 Cm , Guide Extension Catheter (Telescope)6F/7F 150 Cm , Manifold 2 Port /3 Port(Attached Tubing) , Micro Catheter For Cto Retrograde Approach , Iabp Balloon (Intra-Aortic Balloon) , Permanent Pacemakervvi , Asd/Vsd /Dda Deviceall Size , Pda /Asd/Vsd Introducer Sheath With Delivery Cable , Ivc Filter , Y-Connecter , Temporary Pacing Lead6g/5F , Bmv Balloon (All Accessories) , Liga Clip Small With Free Applicator For Urology , Liga Clip Medium With Free Applicator Urology , Liga Clip Large With Free Applicator Urology , Ethibond Suture 1-0 , Ethibond Suture 2-0 , Freaka Tube 12 Fr. , Pap Smear Kit , Endometrial Aspirator Tube (Disposable) , Removac Drain 12 , Removac Drain 14 , Removac Drain 16 , Echilonsttapler With Cartrirege 55*60 , Echilonsttapler With Cartrirege 75*80 , Parmacath Catheter , Inj..Lopromide (Contrast)350 Mg/100 Ml , Disposable Angiography Drape (Water Proof) , Disposable Angioplasty Drape (Water Proof) , Inj Eptifibatide (75Mg/100Ml)
|