Roof-Covering Work – Roof Sealing & Plumbing Work. The Services Include Excerpts: Flat Roofs Of New Buildings, Insulated, Ceiling Over Basement - Courtyard Cellar Ceiling, Traffic Areas Made Of Concrete In Accordance With Din 18532 Components In Contact With The Ground In Accordance With Din 18533 Usage Class N3-V Load Class Slw 30 (Wheel Load Up To 50Kn) Compact Roof Sloped Insulation Foam Glass Bw? 0.046 W/Mk Roof Pitch 2% Sealing With Two Layers Of Polymer Bitumen Membranes (Din 18532-3) Construction Method 2B Sealing Layer On The Thermal Insulation Layer Under A Load Distribution Layer (Load Distribution Layer (Protective Screed) Provided By The Outdoor Facilities Trade On Site) Component I+Ii: Approx. 1,170M² Component Iv+V : Approx. 1,225M² Existing Flat Roofs, Uninsulated, Ceiling Above Basement - Courtyard Cellar Ceiling, Traffic Areas Made Of Concrete In Accordance With Din 18532 Components In Contact With The Ground In Accordance With Din 18533 Usage Class N3-V Load Class Slw 30 (Wheel Load Up To 50Kn) Compact Roof Existing Roof Inclination Partly Approx. 2% Sealing With Two Layers Of Polymer Bitumen Membranes Construction Method 1A Sealing Layer On The Construction Concrete Under A Wear Layer Component 16: Individual Areas Approx. 750M² + 450M² Flat Roofs Existing, Uninsulated, Ceiling Above Basement - Courtyard Cellar Ceiling - Roofed Component In Contact With The Ground According To Din 18533 Compact Roof Roof Pitch Existing Partly Approx. 2% Sealing With Two Layers Of Polymer Bitumen Membranes Construction Method 1A Sealing Layer On The Structural Concrete Under A Wear Layer Individual Areas Approx. 185M² + 400M² Flat Roofs Existing Pavilion Insulated, Ceiling Above Ground Floor U-Value: 0.20 W/M²k Fire Protection Requirement: A (Non-Combustible), Hard Roofing Reinforced Concrete Ceiling With Existing Gradient Bituminous Vapor Barrier Gradient Insulation Foam Glass Bw 0.037 W/Mk, 2.5% In Thermal Average Approx. 190Mm Bitumen Roofing Membrane 2-Layer Gravel Fill A Solar System Is To Be Subsequently Built On The Roof Component 15: Approx. 400M² + Approx. 168M² Flat Roofs Existing Gate Insulated, Ceiling Above Ground Floor U-Value: 0.20 W/M²k Fire Protection Requirement: A (Non-Combustible), Hard Roofing, Bituminous Vapor Barrier, Gradient Insulation, Foam Glass Bw? 0.037 W/Mk, 2.5% (Basic Insulation 100Mm + Gradient Insulation 50-310Mm) Bitumen Roofing Membrane 2-Layer Gravel Fill Component 14: Approx. 45M² + 50M² Flat Roofs Existing Cornices Facade, Area Above E0 And E1 Gradient Insulation Foam Glass 037, 3% Fiber Cement Panels 12Mm Roof Sealing Liquid Plastic Pmma Area Approx. 80M² Elevator Machine Room/Crossing Elevator Over E3 Roof Sealing Upper Roof Surface - Hard Roofing Bituminous Vapor Barrier Mw Slope Insulation Roof Sealing Plastic Membrane Ventilation Hood Area Approx. 20M² Suspended Rear-Ventilated Facade With Standing Seam Sheet Approx. 50M² Individual Measures Existing Main Roof Foil Roof, Ceiling Over E2 And E3 2 Pieces Of Emergency Drains Ceiling Over E2 Dismantling The Roof Construction Section And Closing It Again 6 Pieces Cover Hoods For Existing Extractor Pipes 10 Pieces Renew Roof Ventilators 11 Pieces Close Roof Openings Again 10 Pieces Skylight Rwa 100X100cm 1 Piece Skylight 110X180cm 1 Piece
Contact Information
Address
Mozartstraße 9
Contact No.
+49 30399769-47
Email
Tobias.Freiberg@kapellmann.de
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 81049678
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.