For The Procurement Of Consumable Items For Cardiology Department ( Part-I ) , Drapes , Femoral Drape Sterile, Disposable Catheterization Drape For Covering Patients During Angiography / Catheterization Procedures. Size 100-120×180-200 Cm, With Two 10-12 Cm Adhesive Fenestrations At The Site Of Femoral Artery Puncture ( In The Junction Of Upper 1 / 3Rd And Lower 2 / 3Rd ) , Having Absorbent As Well As Laminated Reinforcement. , Radial Drape Sterile, Disposable Catheterization Drape For Covering Patients During Radial Angiography. Size 120-140×180-200 Cm, With Single 10-12 Cm Adhesive Fenestration At The Site Of Right Radial Artery Puncture ( In The Right Upper Corner, One Foot Away From The Right And The Upper Border Of The Drape ) , Having Absorbent As Well As Laminated Reinforcement. , Antimicrobial Adhesive Sterile Adhesive Transparent Antimicrobial Incision Drape Completely Impervious To Fluids, Size 30-60 Cm X30-45 Cm , Sheaths , Adult Femoral Introducer Sheath Adult Femoral Introducer Sheath 10-12 Cm Long Withhydrophilic Coating Over The Sheath, Hemostatic Valve To Prevent Back Bleeding And Aspiration Of Air, Integrated Side Arm With Attached 3-Way Stopcock; With Suture Eye For Securing Sheath, Kink Resistant, With Dilator Hub Lock Mechanism To Prevent Its Back-Out During Insertionand, In A Kit Containing 18 G, 6-7.5 Cm Puncture Needle And 0.035” Or 0.038” Guide Wire. Size: 5 / 6 / 7 / 8 / 9 F. , Adult Femoral Introducer Long Sheath Adult Femoral Introducer Sheath 20 – 50 Cm Long Withhydrophilic Coating Over The Sheath; 0.035” Or 0.038” Guide Wire Compatible; Hemostatic Valve To Prevent Back Bleeding And Aspiration Of Air, Integrated Side Arm With Attached 3-Way Stopcock; With Suture Eye For Securing Sheath; Kink Resistant; With Dilator Hub Lock Mechanism To Prevent Its Back-Out During Insertion With Smooth And Resistance Free Insertion. Size: 5 / 6 / 7 / 8 / 9 F. , Adult Femoral Introducer Extra Long Sheath Adult Femoral Introducer Sheath >50 Cm Long Withhydrophilic Coating Over The Sheath; 0.035” Or 0.038” Guide Wire Compatible; Hemostatic Valve To Prevent Back Bleeding And Aspiration Of Air, Integrated Side Arm With Attached 3-Way Stopcock; With Suture Eye For Securing Sheath; Kink Resistant; With Dilator Hub Lock Mechanism To Prevent Its Back-Out During Insertion With Smooth And Resistance Free Insertion. Size: 5 / 6 / 7 / 8 / 9 / 10 / 11F And =12F , Adult Femoral Introducer Sheath – Large Bore Adult Femoral Introducer Sheath 10-12 Cm Long With Hydrophilic Coating Over The Sheath, 0.035” Or 0.038” Guide Wire Compatible, Hemostatic Valve To Prevent Back Bleeding And Aspiration Of Air, Integrated Side Arm With Attached 3-Way Stopcock; With Suture Eye For Securing Sheath, Kink Resistant, With Dilator Hub Lock Mechanism To Prevent Its Back-Out During Insertion With Smooth And Resistance Free Insertion. Size: 9 To =12F. , Adult Femoral Introducer Sheath – Long Large Bore Adult Femoral Introducer Sheath 20- 50 Cm Long With Hydrophilic Coating Over The Sheath, 0.035” Or 0.038” Guide Wire Compatible, Hemostatic Valve To Prevent Back Bleeding And Aspiration Of Air, Integrated Side Arm With Attached 3-Way Stopcock; With Suture Eye For Securing Sheath, Kink Resistant, With Dilator Hub Lock Mechanism To Prevent Its Back-Out During Insertion With Smooth And Resistance Free Insertion. Size: 9 To =12F , Pediatric Femoral Introducer Sheath Pediatric Femoral Introducer Sheath With Hemostatic Valve In A Kit Containing Puncture Needle And 0.018-0.021” J Tip / Straight Tip Guide Wire. Size: 3F / 4F / 5F / 6F. , Radial / Brachial Introducer Sheath Radial / Brachial Introducer Sheath With Hemostatic Valve To Prevent Back Bleeding And Aspiration Of Air, Integrated Side Arm With Attached 3-Way Stopcock In A Kit Containing 3-5 Cm Puncture Needle 21 G And 0.021” 40-50 Cm Length Mini Guide Wire ( J Tip / Straight Tip ) , 7-11 Cm Long Sheath. Size: 4F / 5F / 6F / 7F. , Long Radial Introducer Cannulation Kit Radial Artery Cannulation Kit Comprising Of Arterial Sheath With Hemostatic Valve, Puncture Needle 21 G, Straight Tip 0.021”-0.025” 70-80 Cm Length Mini Guide Wire, 16-25 Cm Long Sheath. Size: 4F / 5F / 6F / 7F. , Special Transradial Artery Cannulation Kit Radial Artery Cannulation Kit Comprising Of Hydrophilic Coated Arterial Sheath With Hemostatic Valve, Puncture Needle 20-22 G, Non-Metallic Hydrophilic Straight Tip Mini Guide Wire Of 0.021”-0.025”, Sheath Length Between 10-25 Cm. Size: 4F / 5F / 6F / 7F. , Transradial Sheathless Access System Transradial Sheathless Access System. It Should Include Single Or Dual Long Dilators 135 Cm Each; Hydrophilic Coating; 0.021”-0.035” Wire Compatible; Should Contain Hydrophilic Nitinol / Non Hydrophilic Mini Guidewire ( 45 Cm ) . Dilators Should Be Compatible With Other Brands Guiding Catheter. Size: 5F, 6F, 6.5F, 7F, 7.5 F , Manifold , Manifold – Two Port Manifold –Two Ports With Knobs To Turn “Right” When Open. , Manifold – Three Port Manifold –Three Ports With Knobs To Turn “Right” When Open. , Ptca Kit , Ptca Kit Ptca Kit Containing – ( I ) Three Port Manifold With Knobs To Turn “Right” When Open ( Ii ) One Pressure Line ( Iii ) Saline Connecting Line ( Iv ) Contrast Connectingline ( V ) One Three Way Stop Cock ( Vi ) Short Tube Of 12 To 15 Inches To Connect To Touhy Borst, ( Vii ) One Y-Connector Hemostatic Valve With Spring Type Push And Release Lock Mechanism ( Viii ) One Inflation Device With Manometer Upto 30 Atmosphere ( Easy To Operate With Luminescent Dial ) , ( Ix ) One Luer Lock Controlled Syringe Of 10 Ml With Three Finger Ring, ( X ) Introducer Needle, ( Xi ) Torque Device. , Y-Connector Hemostatic Valve Tuohy Borst Adapter With Dual Valve, Spring Type Push And Release As Well As Rotatory Mechanism. It Should Have Bleed Back Control Valve And Without Formation Of Micro / Macro Air Bubbles Inside It During The Procedure. , Y-Connector Hemostatic Valve Tuohy Borst Adapter With Dual Valve, Spring Type Push And Release.It Should Have Bleed Back Control Valve And Without Formation Of Micro / Macro Air Bubbles Inside It During The Procedure. , Y-Connector Hemostatic Valve Tuohy Borst Adapter With Dual Valve, Rotatory Mechanism.It Should Have Bleed Back Control Valve And Without Formation Of Micro / Macro Air Bubbles Inside It During The Procedure. , Ptca Needle Ptca Insertion Needle Accepting 0.014”, 0.018” And 0.035” Guide Wires. , Inflation Device Inflation Device With Manometer Of 0 To =30 Atmosphere, 30 Cc Capacity And Luminescent Dial Face.Easy To Operate With Ergonomic Design. High Strength Syringe To Maintain High Pressure Setting Without Pressure Loss And Immediate Pressure Release. , Contrast Luerlock Syringe Contrast / Saline Injecting Syringe For Angiography ( For Multiple Hand Contrast Injection In A Single Patient, Non-Breakable ) . A ) 2 Cc, With Luer Lock, No Finger Grip. B ) 5 Cc, With Luer Lock, No Finger Grip. C ) 10 Cc, With Luer Lock, No Finger Grip. , Puncture Needle 21G Sterile Puncture Needle Of 21 Gauge, About 5 Cm Long, Permitting Insertion Of 0.021” Guide Wire, With Plastic Jacket Covering The Needle Part. , Puncture Needle 18G Sterile Puncture Needle Of 18 Gauge, 7 Cm Long, Permitting Insertion Of 0.035” / 0.038” Guide Wire, With Plastic Jacket Covering The Needle Part. , Torque Device Torque Device Accepting Wires ( 0.014”, 0.018”, 0.035”, 0.038” ) , Micropuncture Introducer Set For Vascular Access In Adults Micropuncture Introducer Set For Vascular Access In Adults ( Needle, Guidewire And Co-Axial Introducer Sheath With Dilator And Side Arm ) . It Should Include 20-22 G 6- 7.5 Cm Long Puncture Needle With Protective Plastic Tube Covering; 0.018 Inch, 40-50 Cm Long Guidewire; 4-5 F 10-11 Cm Long Coaxial Introducer Sheath. , Micropuncture Introducer Set For Vascular Access In Paediatrics Micropuncture Introducer Set For Vascular Access In Paediatrics ( Needle, Guidewire And Co-Axial Introducer Sheath ) . It Should Include 20-22 G 3- 5 Cm Long Puncture Needle With Protective Plastic Tube Covering; 0.018 Inchguidewire; 4-5 F Long Coaxial Introducer Sheath. , Three Way Stop Cock , Three Way Stop Cock With One Male And Two Female Ports And Freely Rotating Adapter For Coronary Angiography. , Pressure And Injector Lines , Pressure Line Pressure Line: 120-150 Cm, 4-6 Mm, Compatible With Manifold And Three Way Ports. , Pressure Line Short Connecting Pressure Line Of 20-30 Cm With Male Port In One Side And Female Port In The Other Side. , Injector Line High Pressure Injector Line To Withstand Pressure Up To 1200Psi, 75-100 Cm Length With Luer Lock Male Port And Rotator. , Injector Syringe Injector Syringe Compatible With Medred , Connecting Line Dual Male Connecting Line , Coronary Angiogram Diagnostic Catheters , Femoral Coronary Angiography Diagnostic Catheters Coronary Angiography Diagnostic Catheters =100 Cm For Femoral Approach And Various Curves ( Wherever Applicable ) Of 3.0, 3.5, 4.0, 5.0 F As Required From Time To Time. A ) Judkins Left 4F / 5F / 6F B ) Judkins Right 4F / 5F / 6F C ) Amplatz Left ( Ali / Alii / Aliii ) 4F / 5F / 6F D ) Amplatz Right ( Ari / Arii ) 4F / 5F / 6F E ) L.I.M.A. Catheter 4F / 5F / 6F F ) R.I.M.A Catheter 4F / 5F / 6F G ) Multipurpose Ai, Ii 4F / 5F / 6F H ) Multipurpose Bi, Ii 4F / 5F / 6F I ) 3Drc ( Williams Catheter, 5.2 F ) , Femoral Coronary Angiography Diagnostic Catheters Coronary Angiography Diagnostic Catheters =125 Cm Long For Femoral Approach And Various Curves ( Wherever Applicable ) Of 3.0, 3.5, 4.0, 5.0 As Required From Time To Time. A ) Judkins Left 4F / 5F / 6F B ) Judkins Right 4F / 5F / 6F C ) Amplatz Left ( Ali / Alii / Aliii ) 4F / 5F / 6F D ) Amplatz Right ( Ari / Arii ) 4F / 5F / 6F E ) Multipurpose ( Ai, Ii ) 4F / 5F / 6F , Radial Diagnostic Angiography Catheter Radial Diagnostic Angiography Catheter, Single Catheter For Both Left And Right Coronary Angiography, Tiger Like Curve, Having A-Traumatic Tip With End And Side Hole, Large Lumen. 100-110 Cm Long, 5F. , Radial Diagnostic Angiography Catheter Radial Diagnostic Angiography Catheter, Single Catheter For Both Left And Right Coronary Angiography, Multipurpose A Like Curve With Primary Curve Of 130±5 Degrees, Having A-Traumatic Tip, Large Lumen. 100-110 Cm Long, 5F. , Radial Diagnostic Angiography Catheter Radial Diagnostic Coronary Angiography Catheters, Single Catheter For Cannulation Of Both The Coronary Arteries. With And Without Side Hole, Available In 4, 5, And 6 F, 100 Cm Long And Available In Different Curve Length Of 3.5 To 4.5 Cm. , Radial Diagnostic Angiography Catheter Radial Diagnostic Coronary Angiography Catheters, Single Catheter For Cannulation Of Both The Right And Left Coronary Arteries, Trapease Like, Ultracurve Like Or Similar Shapes, With And Without Side Hole. 5F, And 6F, 100-110 Cm Long. , Ptca Guiding Catheters , Ptca Guiding Catheter, 100 Cm Long: It Should Be Large Lumen ( Minimum Of 0.070” Inner Lumen In 6F And =0.080” In 7F ) , Stainless Steel Braided. It Should Have Atraumatic Soft Tip With Radio Opaque Marker Band At The Tip. A ) Judkins Left Without Side Holes ( Curves 3, 3.5, 4, 5 Cm ) , Size 5F / 6F / 7F / 8F. B ) Judkins Right Without Side Holes ( Curves 3, 3.5, 4, 5 Cm ) , Size 5F / 6F / 7F / 8F. C ) Judkins Right With Side Holes ( Curves 3, 3.5, 4, 5 Cm ) , Size 5F / 6F / 7F / 8F. D ) Ima Guiding Catheter, Size 5F / 6F / 7F. E ) Multipurpose ( Ai, Aii ) , Size 5F / 6F / 7F / 8F. F ) Multipurpose ( Bi, Bii ) , 5F / 6F / 7F / 8F. G ) Amplatz Left ( Curves Al0.75, Al1, Al1.5, Al2, Al3 ) , 5F / 6F / 7F / 8F. H ) Amplatz Right ( Curves Ar1, Ar2 ) , 5F / 6F / 7F / 8F. I ) Voda Left, 5F / 6F / 7F / 8F. J ) Left Coronary Bypass Guide Catheter, 6F / 7F. K ) Right Coronary Bypass Guide Catheter, 6F / 7F. L ) Extra Back-Up ( Ebu ) Left, 5F / 6F / 7F / 8F. M ) Extra Back-Up ( Ebu ) Right, 5F / 6F / 7F / 8F. N ) 3D Right Guiding Catheter, 6F / 7F. O ) Hockey Stick Guiding Catheter, 6F / 7F. P ) Shepherd Crook Right Type Guiding ( Curves 3.5, 4, 5 ) , 6F / 7F. Q ) Head Hunter Guiding Catheter, 6F / 7F. , Ptca Guiding Catheter, 110 Cm Long: It Should Be Large Lumen ( Minimum Of 0.070” Inner Lumen In 6F And =0.080” In 7F ) , Stainless Steel Braided, Inner Layer Coated With Ptfe. It Should Have Atraumatic Soft Tip With Radio Opaque Marker Band At The Tip. A ) Judkins Left Without Side Holes ( Curves 3, 3.5, 4, 5 Cm ) , Size 5F / 6F / 7F / 8F. B ) Judkins Right Without Side Holes ( Curves 3, 3.5, 4, 5 Cm ) , Size 5F / 6F / 7F / 8F. C ) Judkins Right With Side Holes ( Curves 3, 3.5, 4, 5 Cm ) , Size 5F / 6F / 7F / 8F. D ) Ima Guiding Catheter, 5F / 6F / 7F. E ) Multipurpose ( Ai, Aii ) , 5F / 6F / 7F / 8F. F ) Multipurpose ( Bi, Bii ) , 5F / 6F / 7F / 8F. G ) Amplatz Left ( Curves Al0.75, Al1, Al1.5, Al2, Al3 ) , 5F / 6F / 7F / 8F. H ) Amplatz Right ( Curves Ar1, Ar2 ) , 5F / 6F / 7F / 8F. I ) Voda Left, 5F / 6F / 7F / 8F. J ) Left Coronary Bypass Guide Catheter, 6F / 7F. K ) Right Coronary Bypass Guide Catheter, 6F / 7F. L ) Extra Back-Up ( Ebu ) Left, 5F / 6F / 7F / 8F. M ) Extra Back-Up ( Ebu ) Right, 5F / 6F / 7F / 8F. N ) 3D Right Guiding Catheter, 6F / 7F. O ) Hockey Stick Guiding Catheter, 6F / 7F. , Radial Coronary Angioplasty Guiding Catheters, Single Catheter For Cannulation Of Both The Coronary Arteries. Available In 5, And 6 F, 100 Cm Long And Available In Different Curve Length Of 3.5 To 4 Cm And With The Option Of Having Side Holes. , Radial Guide Catheter, Ikari Left Curve. 3.5, 4, 4.5, 5 Size, 5F / 6F For Radial Angioplasty. , Radial Guide Catheter, Ikari Right Curve. 1.0 / 1.5 / 2.0 / 2.5 Size, 5F / 6F For Radial Angioplasty. , Radial Guide Catheter, Tiger Type Curve. 5F / 6F Size For Radial Angioplasty. , Radial Hydrophilic Sheath-Less Guide Catheter, 7 / 7.5F Size. , Radial Guide Catheter, Mac Curve. 3.0, 3.5, 4 Size, 5F / 6F For Radial Angioplasty. , Angiographic Guide Wire , Angiographic Guide Wire 0.035”, Ptfe Coated, ‘J’ Tip, Standard Length ( 150-160 Cm ) , Angiographic Guide Wire 0.035”, Ptfe Coated, ‘Straight’ Tip, Standard Length ( 150-160 Cm ) , Angiographic Guide Wire, Ptfe Coated, ‘J’ Tip, Extra Length Of ( 250-260 Cm ) . Diameter ( I ) 0.038” ( Ii ) 0.035” ( Iii ) 0.032” ( Iv ) 0.025” ( V ) 0.021” , Radifocus Angiographic Guide Wire ( Terumo ) , Hydrophilic Polymer Coated; J Tip, Standard Length ( 150-180 Cm ) , Diameter ( I ) 0.021” ( Ii ) 0.025" ( Iii ) 0.032” ( Iv ) 0.035” ( V ) 0.038” , Radifocus Angiographic Guide Wire ( Terumo ) , Hydrophilic Polymer Coated; ‘Straight’ Tip, Standard Length ( 150-180 Cm ) , Diameter ( I ) 0.021” ( Ii ) 0.025" ( Iii ) 0.032" ( Iv ) 0.035" ( V ) 0.038” , Radifocus Angiographic Guide Wire ( Terumo ) ; Hydrophilic Polymer Coated; ‘Straight’ Tip, Exchange Length ( 250-260 Cm ) , Diameter ( I ) 0.021” ( Ii ) 0.025" ( Iii ) 0.032" ( Iv ) 0.035" ( V ) 0.038” , Amplatzer Super Stiff Guide Wire, Long Length Of 260 Cm To 300 Cm Of 0.035” Size. , Amplantz Extra Stiff Guide Wire, Long Length Of 260 Cm To 300 Cm Of 0.035” Size.. , Amplantz Ultra Stiffguide Wire, Long Length Of 260 Cm To 300 Cm Of 0.035” Size. , Ptca Guidewire , Stainless Steel Core Workhorse Ptca Guidewire 0.014” With Soft Shaping Ribbon Tip And Hydrophilic Or Hydrophobic Coating, Length 175-190 Cm , Stainless Steel Core Workhorse Ptca Guidewire 0.014” With Medium / Intermediate Support With Soft / Floppy Tip 175 - 190 Cm , Stainless Steel Core Workhorse Ptca Guidewire 0.014” With Extra Support With Soft / Floppy Tip 175-190 Cm , Hybrid Core Workhorse Ptca Guidewire With Soft / Floppy Tip 175-190 Cm , Hybrid Core Workhorse Ptca Guidewire With Medium / Intermediate Support With Soft / Floppy Tip 175 - 190 Cm , Hybrid Core Workhorse Ptca Guidewire With Extra Support With Soft / Floppy Tip 175-190 Cm , Ptca Guide Wires, 0.014”, 180-190 Cm Long, Nitinol Distal Super Elastic Core For Kink Resistance And Shape Retention, Silicon Coating For Distal 2 Cm And Hydrophilic Coating Of Rest Of The Wire Length With Tip Loadof 1.0 Gm., 0.6 Gm., And 3.6 Gm. , Steerable Ptca Guide Wire With Floppy Tip, Elastinite Nitinol Core, Soft Shaping Ribbon Tip And Hydrophilic Or Hydrophobic Coating. , Steerable Ptca Extra Support Guide Wire With Durasteel Core Material, Core To Tip Design, Floppy Tip. With Hydrophobic Coating And With Hydrophilic Coating. , Steerable Ptca 0.014” Guide Wire, Distal Nitinol Core And Rest Stainless Steel, Double Coil Tip For Shape Retention, Hydrophilic Coating. , Ptca Guide Wire With Polymer Coated, Hydrophilic, Steel Core And Transitionless Tip With Various Tip Strength And Tip Load For Torturous Vessels. , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 16-20 Cm, Tip Load Of 0.8 Gm., Tip Size Of 0.014”, Tip Radiopacity Of 3 Cm Or More , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 16-20 Cm, Tip Load Of 0.8 Gm., Tip Size Of 0.009”, Tip Radiopacity Of 16 Cm. , Ptca Guide Wire 0.014” With Ptfe Coating Over Shaft, Polymer Jacket And Hydrophilic Coating Length Of 17 Cm, Tip Load Of 1.0 Gf, Tapered Tip Size 0.010”, Stainless Steel Spring Coil Of 16 Cm Length And Tip Radiopacity Of 16 Cm, Length 190Cm , Ptca Guide Wire 0.014” With Ptfe Coating Over Shaft, Polymer Jacket And Hydrophilic Coating Length Of 17 Cm, Tip Load Of 0.6 Gf, Tapered Tip Size 0.010”, Stainless Steel Spring Coil Of 16 Cm Length And Tip Radiopacity Of 16 Cm, Length 190 And 300 Cm , Ptca Extra-Support Guide Wire With Ptfe Coating Over Shaft, Tip Load Of 0.7 Gm., Tip Size Of 0.014”, Spring Coil Of 4 Cm And Tip Radiopacity Of 4 Cm. , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm. Various Tip Loads ( 3, 4.5, 6, 12 ) , Ptca One Piece Core Wire With Joint Less Spring Coil Length 15 Cm With Cone Tip, 180-190 Cm Long, Tip Radiopacity 15 Cm, Wire Diameter 0.010” With A Tip Load Of 1.7 Gm., Wire Diameter 0.011” With A Tip Load Of 3.5 Gm., And Wire Diameter 0.012” With A Tip Load Of 4.5 Gm. , Ptca Guide Wire For Cto With Extra-Support, Tip Load Of 9 Gm., Tip Size Of 0.009”, Length 180-190 Cm, With Spring Coil And Tip Radiopacity Of 11 Cm And Spring Coil And Tip Radiopacity Of 20 Cm. , Ptca Guide Wire For Cto With Stainless Steel Core, Hydrophilic Tapered Tip With Radiopacity Of 16 – 20 Cm Of Varying Tip Load ( 9-20 Grams ) , Ptca Guide Wire For Septal Collateral Surfing, Joint Less Spring Coil 0.014” One Piece Core Ptca Guide Wire With Tip Radiopacity 3 Cm, Length 180 Cm, Tip Load Of 0.5 Gm. And 0.7 Gm. , Ptca Guide Wire For Epicardial Collateral Surfing, With Hydrophilic Coating, Spring Coil Of 19Cm Length, 0.3 Gf Tip Load, Distal 3 Cm Single Wire Rope Coil, Core Connected To Tip With Twist Wire, 3Cm Tip Radiopacity, Length 190 And 300 Cm , Dedicated Externalization 0.010” Guidewire, 8 Cm Spring Coil Length, 3.0 Gf Tip Load, Tip Radiopacity Of 3 Cm With Length >300 Cm. , 0.014” Extension ( Doc ) Wire Of At Least 165 Cm For Exchange Of Micro Catheters And Other Over The Wire Devices , Ptca Balloon Catheters , Predilatation Semicompliant Balloon Ptca Pre-Dilatation, Monorail / Rapid Exchange Balloon ( Semi Compliant ) . Low Entry Profile ( =0.017” ) And 5F Guide Catheter Compatibility. Radio-Opaque Markers At Both Ends. Diameters ( Mm ) : 1.0, 1.25, 1.5, 2.0, 2.5, 3, 3.5, =4.0. Length: =10 Mm To =30 Mm. ( Only Manufacturers / Firms Having All Mentioned Diameters And Lengths Will Be Considered. ) , Predilatation Semicompliant Balloon: Ultralow Entry Profile Ptca Pre-Dilatation Semi-Compliant Balloon, Monorail / Rapid Exchange. Ultra-Low Entry Profile ( =0.016” Inch ) With 5F Guide Catheter Compatible, Hydrophilic Coating Of The Distal Monorail Part. Radio-Opaque Marker For Visibility. Diameters ( Mm ) : 1.0, 1.2 / 1.25, 1.5, 2.0. Length: =10 Mm To =20 Mm. ( Only Manufacturers / Firms Having All Mentioned Diameters And Lengths Will Be Considered ) , Predilataion Sc Balloon: Ultralow Entry Profile Ptca Pre-Dilatation Semi-Compliant Balloon, Lowest Tip Entry Profile Of =0.016”, Crossing Profile Of =0.021”, Zero Fold Or Minimum Fold With Low Profile And Marker For Better Visibility, Stepwise Transition Stiffening For More Pushability For Difficult To Cross Lesions. Radio-Opaque Marker ( Single ) At The Center Of The Balloon In Small Diameter Balloons. Diameter ( Mm ) : 1.2 / 1.25, 1.5, 2.0. Length: Minimum 6-8 Mm To 12-15 Mm. ( Only Manufacturers / Firms Having All Mentioned Diameters And Lengths Will Be Considered. ) , Pre-Dilatation Sc Over The Wire Balloon Ptca Pre-Dilatation Semi-Compliant Over The Wire Balloon ( Otw ) With Short Balloon Taper, Low Entry Profile ( =0.016” ) . Diameter –1.2 / 1.25, 1.5, 2.0, 2.5, 3.0 Mm Or More Length – Minimum 6-8 Mm To 20Mm Or More. , Ptca Predilation Cto Balloon Ptca Pre-Dilatation Non Compliant, Monorail / Rapid Exchange Balloon With Lowest Crossing Profile For Crossing Difficult To Cross Cto Lesions, Having Smallest Balloon Size Of 0.8±0.1 Mm Diameter And Length Of 8±2 Mm. , Post-Dilatation High Pressure Nc Balloon ( Rbp 16 Atm ) High Pressure Non-Compliant Balloon With Low ( <0.018” ) Lesion Entry Profileand =16 Atm Rbp, 5F Guiding Compatible, Smooth, Rounded Distal Tip And No Edge Over-Dilatation At Higher Pressure; With Least Balloon Overhang At The Edges. Available Diameter ( Mm ) : 2.0, 2.5, 2.75, 3.0, 3.5, =4. Length ( Mm ) : =10 To =30. ( Only Manufacturers / Firms Having All Mentioned Diameters And Lengths Will Be Considered. ) , Post-Dilatation High Pressure Nc Balloon ( Rbp 20 Atm ) High Pressure Non-Compliant Balloon With =20 Atm Rbp, 5F Guiding Compatible, Smooth, Rounded Distal Tip And No Edge Over-Dilatation At Higher Pressure. Available Diameter ( Mm ) : 2.25, 2.5, 2.75, 3.0, 3.25, 3.5, 3.75, 4, 4.5, 5.0. Length ( Mm ) : Minimum 6 / 8 Mm To =20 Mm. ( Only Manufacturers / Firms Having All Mentioned Diameters And Lengths Will Be Considered. ) , Ultra-High Pressure Non-Compliant Balloon Ultra-High Pressure Non-Compliant Balloon With =30 Atm Rbp For Highly Fibrotic Or Calcific Vessels, No Edge Over-Dilatation At Higher Pressure; With Least Balloon Overhang At The Edges. Diameter ( Mm ) : 2.0, 2.5, 3.0, 3.5, =4. Length ( Mm ) : Minimum 6-8Mm To =20 Mm. ( Only Manufacturers / Firms Having All Mentioned Diameters And Lengths Will Be Considered. ) A ) Balloon Only B ) Balloon With Dedicated Inflation Device To Inflate Balloon Upto 45 / 50 Atm. , Coronary Balloon For Controlled Plaque Modification Scoring Balloon Catheter With Flexible Nitinol Scoring Element In A Helical Fashion / Dual-Wire For Plaque Modification On A Balloon For Coronary Applications, Of Various Lengths And Diameters , Ptca Cutting Balloon Ptca Cutting Balloon With Blades Or Such New Cutting Device At The Surface Of The Balloon, Blades / Cutting Devices Arranged With Hinges In Every 5 Mm Of Balloon For Better Trackability. Diameter 2.0Mm-4.00 Mmlength 6-15 Mm , Cto Balloon For Retrograde Approach Ptca Balloon For Retrograde Approach Of Cto: Should Be Available In Both Regular And Long Lengths For Retrograde Approach, Should Be Available As Over The Wire ( Otw ) , Available In All Sizes And Lengths , Perfusion Balloon Rapid Exchange Low Pressure Atraumatic Microporous Ptfe Balloon Catheter For Local Infusion Of Drugs, Catheter Length > 130 Cm. Size1.5- 4.0Mm , Drug Eluting Coronary Balloons , Deb Coronary Paclitaxel Eluting Balloon Dilation Catheter, 0.014” Wire Compatible, Rapid Exchange. Diameter ( Mm ) 2.0, 2.5, 2.75, 3.0, 3.5, 4.0. Length ( Mm ) 12 / 15 Mm Upto 40 Mm In Various Lengths. , Deb Coronary Sirolimus Eluting Balloon Dilation Catheter, 0.014” Wire Compatible, Rapid Exchange. Diameter ( Mm ) 2.0, 2.5, 2.75, 3.0, 3.5, 4.0. Length ( Mm ) 12 / 15 Mm To=40 Mm In Various Lengths. , Microcatheters , Coronary Microcatheter With Distal Diameter Of 1.9 Fr Or Less, Proximal Diameter 2.6F, Ptfe Coated Inner Layer, And Distal Hydrophilic Coating At The Outer Layer, Flexible Tip With Outer And Inner Taper With Gold Marker At Distal Tip For Enhanced Distal Visibility To Cross Difficult Lesions, From 130-160 Cm Length , Complex Channel Or Micro-Channel Crossing Catheter With Hydrophilic Coating Of Distal Segment, Kink Resistant Tapered Tip Of 0.016”, Tungsten Braiding, +10 Elliptical Stainless Steel Braids For Better Support, From 130-160 Cm Length. , Coronary Wire Braded Micro-Catheter For Channel Dilatation With Platinum Marker At Distal Tip For Clear Visibility. Having 8× 0.12 Mm Wire Embedded In The Shaft, Long Taper Tip Of 15 Cm, Tip 1.7-1.8 Fr., Mid Shaft Of 2.1-2.2 R. And Proximal End Of 3.3-3.4 Fr., Length 130-140 Cm. , Double Lumen Microcatheter Double Lumen Microcatheter With Hydrophilic Coating, Proximal Outer Diameter 2.9F, Tip Entry Diameter < 1.5 F, Radiopaque Markers At Both Exit Port, 0.014” Guidewire Compatibility, 6F Guide Compatibility. Length 135-145Cm , Coronary Microcatheter With Distal Outer Diameter Of 2.7 F And Proximal Outer Diameter Of 2.9 F, With Guidewire Compatibility Of 0.021” For Microcoil Embolization. , Thrombosuction Catheters , Intra-Coronary Thrombus Extraction Catheter, Short Tip Monorail Segment With Removable Stiffening Stylet For Pushability, Hydrophilic Coating, Big And Round Suction Lumen, 0.014” Wire Compatibility – Available In 6F And 7F , Coronary Thrombus Extraction Catheter With Full Length Braided Shaft With Hydrophilic Coating Without Stiffening Stylet – Size 6F , Coronary Thrombus Extraction Catheter With Full Length Braided Shaft With Hydrophilic Coating With Embedded Wire For Enhanced Deliverability And Kink Resistance – Size 6F , Coronary Thrombus Extraction Catheter Compatible With 5 French Guiding Catheter. , Guide Catheter Extension , Guide Extension Catheter, 5F / 5.5 F / 6F / 7F / 8F, Coil-Reinforced Extension, Kink Resistant, Rapid Exchange With 150 Cm Working Length, Soft Tip With Radiopaque Marker. , Guide Extension Catheter, 6F / 7F / 8F, Rapid Exchange, 150 Cm Working Length With Short Hypotube Transition For Reducing Stent Interaction / Deformation And Having Dedicated Catheter For Using In Transradial Pci, Soft Tip With Radiopaque Marker At Both End. , Special Large Lumen Rapid Exchange Guide Extension Catheter Compatible With 6 / 7 / 8 F Guiding Catheter With Ids For 6 F: 0.057 Inch; 7F: 0.063 Inch And 8F: 0.072 Inch; Soft Tip With Radiopaque Marker. All Sizes Should Be Available , Mother And Child Catheter Assembly For Using Smaller Guide Catheter Inside Large Guide Catheter. , Cto Re-Entry Balloon Catheter , Over The Wire, Blunt Microdissection Catheter With 1-Mm Rounded Tip For Antegrade Dissection Re-Entry , Flat Re-Entry Balloon For Cto With Two Exit Port For Wire Entry In To The True Lumen , Penetrating Wire For Antegrade Dissection And Reentry , Vascular Closure Device , Femoral Percutaneous Closure Device ( Thrombin / Collagen Mediated Closure ) . , Femoral Percutaneous Suture Mediated Closure Device For > 8F Closure. , Radial Closure Device Comprising Of Compression Pad ( Pneumatically Inflated With A Syringe ) With Anatomic Soft-Wrist Support Pad. , Temporary Pacing Leads , Balloon-Flow Assisted Bipolar Temporary Pacing Electrode Catheter, Must Have Marking On Catheter, With Depth Marker Sizes-5F / 6F , Bipolar Temporary Pacing Lead, With Central Removable Stellate For Maintaining Support And Tip-Curve. 5F / 6F / 7F. , Calcified Lesion Modification , Rotational Atherectomy Catheter Burr For Rotational Coronary Atherectomy, 1.25- 2.5 Mm With Rotational Atherectomy Catheter Burr With Advancer Rota Burr And Advancer With Floppy / Extrasupport / Drive Rota Guide Wire 0.009" With Tip.014" , Ivl-Rapid Exchange Ballon Intravascular Lithotripsy Intuitive Catheter With Rapid Exchange System For Treating Highly Calcified Lesions, - In Various Sizes And Diameters , Intravascular Lithotripsy Intuitive Catheter With Over The Wire System For Treating Highly Calcified Lesions, - In Various Sizes And Diameters , Intravascular Lithotripsy Connector Cable , Iabp Consumables , Iabp Balloons With Accessories For Insertion, Compatible With The Existing Model Ac3 Optimus – Iabp And Autocat ( Arrow International Inc ) ( With Required Connector ) . Sizes Available In 20, 24 / 25, 30 / 32, 34 / 36, 40 Ml. , Refilling Of Helium Gas Cylinders From Time To Time For The Existing Iabp Machine Of Arrow. , Impella , Impella Pump Catheters With All Accessories For Use, 2.5 Liter Pump , Intracoronary Imaging And Physiology Catheters , Intracoronary Pressure Wire Catheter ( Ffr & Ifr ) For Ptca With Wireless Connectivity Compatible With Philips Ivus Machine In Cath Lab. , Ivus Catheter With Pullback Sledge: High Resolution, Rapid Exchange, Phased Array Ivus Catheter With Operating Frequency 20 Mhz / 64 Element With 5F / 6F Guide Compatibility, 0.014” Guide Wire Compatible, Tip To Transducer Length 2.5 To 10 Mmfor Coronary And Peripheral Intervention Transducer Compatible With Philips Ivus Machine Available In Cath Lab Catheter With Pullback Sledge For Automatic Pullback , Ivus Catheter With Pullback Sledge: High Resolution, Rapid Exchange, Mechanical Ivus Catheter With Operating Frequency 45 Mhz / Single Element With 5F / 6F Guide Compatibility, 0.014” Guide Wire Compatible For Coronary Intervention Transducer Compatible With Philips Ivus Machine In The Cath Lab. Catheter With Pullback Sledge For Automatic Pullback , Embolization Coils / Particles , Embolization Coils Of 0.014” Diameter, Different Lengths , Embolization Coils Of 0.018" Diameter, Different Lengths , Embolization Coils Of 0.021" Diameter, Different Lengths , Embolization Coils Of 0.035" Diameter, Different Lengths , Embolization Coils Of 0.038" Diameter, Different Lengths , Microcoil ( 0.018" Diameter ) Delivery System A ) Coil Delivery Micro Catheter B ) Coil Pusher , Sterile Pva Particle For Intravascular Embolization, 300-1000 ?M Diameter. , Coronary Filter / Protection Devices , Rapid Exchange Coronary Low-Profile Protection Filter Device 2.5-5.0Mm , Distal Protection Device 0.014" Basket Type. , Distal Protection Device .014" Wire Umbrella Type Coronary Filter. , Snare / Retrieval System , Snares: Dual Plane Snare System With Radio-Opaque Loop, Small And Large Loop , Amplatz Goose Neck Snare Kit Of Small And Large Size. , Intra-Coronary Foreign Body Retrieval Forceps , Radio Opaque Micro Snare, Small Loop, 90 Degree With Kink Resistant Shaft. , Intra-Vascular Retriever Set. , Cardiac Bioptomes For Endomyocardial Biopsy. 4F, 5F. 6F. A ) 100+5 Cm For Femoral Approach B ) 45+5 Cm For Internal Jugular Approach. , Peripheral Balloons , Peripheral Long Balloon, Semi Compliant, Various Diameters Of 4 To 24 Mm. Length: 20 To =100 Mm. Otw Over 0.035" Guide Wire. , Peripheral Long Balloon, Semi Compliant, Various Diameters Of 4Mm To =8 Mm. Length: 20 To =100 Mm. Otw Over 0.018" Guide Wire. , Peripheral Balloon, Semi Compliant, Various Diameters Of 4Mm To 8Mm. Length: 20 To 40 Mm. Monorail, Compatible Over 0.014" Guide Wire. , Scoring Balloon Catheter Scoring Balloon Catheter, With Two / Three Rectangular Spiral Sheets / Wires ( Nitinol Scoring Element ) On A Semi-Compliant Balloon For Peripheral Applications. Otw Over 0.014" / 0.018" Guide Wire. Diameter ( Mm ) : 4.0 To 8.0 Mm. Length ( Mm ) : 20 To 100 Mm Working Length: 50 Cm, 90 Cm, 155 Cm ( Only Manufacturers / Firms Having All Mentioned Diameters And Lengths Will Be Considered. ) , Peripheral Cutting Balloon Peripheral Cutting Balloon With Blades At The Surface Of The Non-Compliant Balloon, 5.0 To 8.0 Mm Diameter Length Up To 20 Mm. Otw Over 0.018" Guide Wire. Working Length: 50 Cm, 90 Cm, 135 Cm ( Only Manufacturers / Firms Having All Mentioned Diameters And Lengths Will Be Considered. ) , Paclitaxel Eluting Peripheral Drug Eluting Balloon Catheter , Sirolimus Eluting Peripheral Drug Eluting Balloon Catheter , Peripheral Guidewires , Steerable Pta 0.035" Guide Wire With Core To Tip Design, Hydrophobic Coating, Soft Atraumatic Tip, Supportive. Lengths: 145 Cm, 190 Cm And 300 Cm , Steerable Pta Guide Wire With Floppy Tip, Scitanium Stainless Steel Alloy Core, Extra-Support Of 0.018" Diameter, =300 Cm Long. Tip Non-Hydrophilic Or Tip Hydrophilic. , Steerable Pta High Support Guide Wire Of 0.018", Body Ptfe / Hydrophobic Coated, Distal Hydrophilic Coating, Distal Radiopacity Of 2 Cm, =300 Cm Long. , Torque Device For Large Wires ( 0.018" To 0.038" ) , Contra-Lateral Femoral Sheath With Dilator, 30-55 Cm Long. 6F, 7F, 8F, 9F, 10F , Carotid Angiography / Angioplasty Catheters , Carotid Angioplasty 90 Cm Sheath With Hydrophilic 20 Coating, Radiopaque Band, Soft Tip. Size: 5 To 9 F , Dedicated Guiding Catheter For Carotid With Flexible Shapable Tip. Size:6, 7, 8 F , Cobra Catheter ( C1, C2, C3 ) : 4 / 5 / 6 F. , Picard Catheter, 5F. , Head Hunter Catheter: 5 / 6 F. , Shepherd Crook Catheter ( 0.8 & 1 ) : 5 / 6 F. , Simmons Catheter, 5 / 6 F, ( Sim1, Sim2 ) , Sidewinder Catheter, 5 / 6 F. , Bernstein Curve Angiography Catheter , Vtk ( Vitek ) Catheter For Carotid Angiography, 125 Cm Long, 5F , Filter Type Rapid Exchange Cerebral Protection Device Compatible With 0.014" Wire, 4-8 Mm Diameter. , Polyurethane Nitinol - Basket Type Rapid Exchange Cerebral Protection Device Compatible With 0.014" Wire, 4-8 Mm Diameter. , Renal Angioplasty Catheters , Guiding Cath With Attached Valve, Renal Double Curve. Size: 6 - 8 F , Guiding Cath With Attached Valve, Multipurpose 55 - 95 Cm. Size: 7-9 F , Guiding Cath With Attached Hemostasis Valve, Contralateral 55- 95 Cm. Size: 7-9 F , Renal Guiding Cath. Length 55Cms / 65Cms. Size: 6, 7, 8F , Ptmc / Pbmv , Mullins Sheath With Side Arm For Adult Procedure Size: 9-14 F. , Mullins Sheath With Side Arm For Pediatric Procedure Size: 4-8 F. , Trans-Septal Puncture Needle, Curved, For Atrial Septal Puncture. For Adult Use. , Trans-Septal Puncture Needle, Straight, For Atrial Septal Puncture. For Adult Use. , Trans-Septal Puncture Needle, Curved, For Atrial Septal Puncture. For Pediatric Use. , Ptmc Accessory - Spring Coil Wire, Extra Stiff, Metallic For Ptmc / Bmv. , Ptmc Accessory - 14 F Dilator For Ptmc / Bmv , Ptmc Accessory - Stylet Or J Shaped Lv Entry Wire During Ptmc / Bmv. , Noodle Wire, 0.035" Diameter, 300 Cm Long. , Mitral Valvuloplasty Double Lumen Ptmc Balloon With Vent Tube And Hole In The Outer Layer Of The Balloon, Different Sizes, Without Accessories. , Ptmc Double Lumen Balloon With No Hole On The Balloon Wall, No Vent Tube, Different Sizes, Without Accessories. , Mitral Valvuloplasty Double Lumen Ptmc Balloon With Vent Tube And Hole In The Outer Layer Of The Balloon, Different Sizes, With All Accessories. , Ptmc Double Lumen Balloon With No Hole On The Balloon Wall, No Vent Tube, Different Sizes, With All Accessories. , Bpv , Percutaneous Pulmonary Valvuloplasty Balloon Catheters Of Different Sizes; Available In Sets Containing Balloon Catheter, Dilator, Guide Wire, Caliper With Technology For Stable Position Of Balloon Across Pulmonary Valve During Dilatation. , Bav , Percutaneous Aortic Valvuloplasty Balloon Catheters Of Different Sizes; Available In Sets Containing Balloon Catheter, Dilator, Guide Wire, Caliper With Technology For Stable Position Of Balloon Across Aortic Valve During Dilatation. , Percutaneous Valvuloplasty Balloon Catheter For Adult Use, Of Different Sizes Available Upto 30Mm And Length Upto 60Mm, With Higher Rbp ( 3-6 Atm ) , Percutaneous Valvuloplasty Balloon Catheter For Adult Use With Dumbbell Shaped Narrowing Of The Central Part For Precise Positioning Across A Valve, Of Different Diameter Of Mid-Size Available Upto 25 / 26 Mm And Length Upto 40 / 50 Mm, With Higher Rbp ( 3-5 Atm ) . , Nucleus Dilatation Balloon With Three Markers, Initial Expansion Of Ends And Later Expansion Of Central Part. , Coarctoplasty , Percutaneous Transluminal Dilation Balloon With Markers For Coarctation Of Aorta With High Rbp. All Sizes And Various Lengths. , Ultra-High Pressure Valvuloplasty Balloon Dilation Catheter With Multiple Markers. , Percutaneous Valvuloplasty Bib ( Balloon-In-Balloon ) Balloon Catheter Of Different Length And Diameter. , Atrial Septostomy Catheter , Atrial Septostomy Catheter Dual Lumen Shaft, Radio Opaque Catheter Body, Marker In The Balloon For Balloon Positioning, 30-45° Angulated Tip. Over The Wire. , Fogarty Catheter For Atrial Septostomy, 5F- 6F , Asd / Vsd / Device Delivery System , Asd / Vsd / Pda Delivery System Kit Containing I ) Delivery Sheath -Flex Kink Resistant With Back Bleed Prevention Hemostatic Valve And Side Port, Ii ) Dilator, Iii ) Delivery Cable, Iv ) Loader 6 / 7 / 8 / 9 / 10 / 11 / 12 / 13 / 14F. , Sizing Balloon For Asd Device Closure: Oval Shaped , Sizing Balloon For Asd Device Closure: Circular Shape , Sizing Plate For Balloon Sizing Of Asd , Cardiac Catheterization Catheters , Balloon Flotation Angiography Catheter ( Berman Type ) With Side Holes. 5F, 6F, 7F. , Balloon Flotation Angiography Catheter ( Berman Type ) With Side Holes And End Hole At The Tip For Wire Access. 5F, 6F, 7F. , Pigtail Catheter For Neonatal And Pediatric Use, Short Length Of 70-80 Cm: 4F, 5F. , Pigtail Catheter, 6-12 Side Holes, High Flow Rate For Adult Use. Straight Pigtail: 4, 5, 6 , 7 F. , Pigtail Catheter, 6-12 Side Holes, High Flow Rate For Adult Use. Marker Pigtail ( With Radio Opaque Markers ) : 6, 7 F. , Pigtail Catheter, 6-12 Side Holes, High Flow Rate Foradult Use. Angled Pigtail ( With 145-155 Degree Angle ) : 5, 6 F. , Nih Catheter, With End Hole And Side Holes, 5 / 6 F. , Nih Catheter, With Side Holes Only, 5 / 6 F. , Single Lumen Balloon Flotation Wedge Pressure Catheter ( Swan Ganz Type ) With End Hole. 4F, 5F, 6F. 7F. , Goodale-Lubin Catheter, 4F / 5F / 6F. , Multi Track Angiography Catheter For Angiography While Catheter Is Over The Wire By Short Monorail Part At Distal Tip, Size 5-7 F. , Angiographic Vessel Sizing Catheters Of Various Configuration, Non-Braided, 6-10 Side Holes, 0.035" Wire Compatible, With 10-20 Radiopaque Marker Bands 1 Cm Apart, Length Between 65 - 100 Cm, Size: 4 / 5 / 6 F , Specialized Sheaths , Steerable Long Sheath With Hemostatic Valve And Deflectable Tip, 6F To 14 F, Length 50Cm, 70 Cm And =80 Cm. , Bidirectional, Steerable Soft-Tip Design, Guiding Sheath With Small And Large Curve And Variable Reach, Auto Lock ( Between 8-12F ) , Total Length =90 Cm. , Special Braided Long Sheaths With Side Arm: Other Than Mullins Curve: All Standard Sizes And Curve , Long Sheaths Of Various Sizes With Side Arm ( Balkan / Hausdorff Type ) , For Pediatric Interventions. 4F, 5F, 6F. 30 To 50 Cm Long. , Long Sheaths Of Various Sizes With Side Arm ( Balkan / Hausdorff Type ) , For Adult Interventions. 6F, 7F, 8F. 60 To 80 Cm Long. , Shuttle Sheath, With Flexor Tuohy Borst Side Arm, 60 Cm Long, 6F, 7F, 8F, 9F. , Shuttle Sheath, With Flexor Tuohy Borst Side Arm, 80 Cm Long, 6F, 7F, 8F, 9F. , Pealway Introducer Sheath, 0.035" Compatible, 6F / 7F / 8F / 9F , Lv Wires , 0.035" Stiff Guide Wire With Ptfe Coated Stainless Steel Core, Tapering Gradually To The Tip; With A Pre-Shaped Curve Of Diameter 30Mm At The End. The Wire Should Have An Smooth Transition Phase From Stiff To Soft That Commences At The Start Of The Curvature. 260 Cm Length , 0.035" Extra Stiff Ptfe-Coated Stainless Steel Guide Wire, Should Have 4 -7 Cm Of Flexible Tip, Should Have Enhanced Visibility. Lengths Of = 260 Cm , 0.035” Ptfe-Coated Stainless Steel Guide Wire. Smooth Tapered Core Design, Pre-Shaped Curve At The End Where The Curve Performs At Least One Revolution Or Loop With A Decreasing Radius. Curve Size: Extra Small, Small And Large. Length = 260 Cm , Pre Bav / Pd Balloons , Over The Wire Balloon Valvuloplasty Catheter – Non-Compliant With Rapid Inflation And Deflation, Rupture Resistant, With Two Radiopaque Markers At Each End, 0.035” Guidewire Compatible, With Two Lumen And Luerlock Hub One Each For Placement Over The Wire And Balloon Inflation / Deflation. Shaft Length 110 Cm Balloon Diameter: 18, 20, 21, 22, 23, 24, 25, 26, 28 Mm Length: 4.5 Cm Sheath Compatibility: 11- 14 F ( Only Manufacturers / Firms Having All Mentioned Diameters And Lengths Will Be Considered. ) , Over The Wire Balloon Catheter For Temporary Occlusion Of Large Vessels Like Aorta-Compliant Balloon Made Up Of Polyurethane Material, 0.035” Guidewire Compatible, With Two Lumen One Each For Placement Over The Wire And Balloon Inflation / Deflation, With Two Radiopaque Markers At Each End. Balloon Diameter: 32, 46 Mm Catheter Length: 100, 120 And 140 Cm Sheath Compatibility: 12- 14 F ( Only Manufacturers / Firms Having All Mentioned Diameters And Lengths Will Be Considered. ) , Miscellaneous Consumables , Radiolucent Ecg Electrode , Pressure Bag With Manometer For Iv Infusion , Pressure Domes With Cables Compatible With Philips Allura Fd10 / 20 , Disposable Image Intensifier Cover For Philips Fd10 / 20 , Dvd With Rgssh Printed ( 4-5 Gb Storage ) , High Performance 9V Alkaline Battery For Use In Temporary Pulse Generator
|