Construction Of 50 Bedded District Hospital Complex And Procurement Of Equipment At Hnahthial, Mizoram-Earthwork In Excavation Exclusive Of Compensation Of Earth In - ( A ) Ordinary Soil ( Pick Work ) . 2 ( B ) Hard Soil 3 ( E ) Chiselling 4 Earthwork In Excavation In Foundation Trenches Or Drains Etc. ( Not Exceeding 1.5M In Width Or 10Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5M Including Getting Out Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Metres. ( A ) Ordinary Soil 5 ( B ) Hard Soil 6 Earthwork In Excavation In Foundation Trenches Etc. Not Exceeding 2 Meters Depth Including Dressing Of Bottom And Sides Of Trenches And Subsequent Filling And Compaction In 15Cm Layers As In Column Foundations, Fence Posts, Etc. And Disposal Of All Surplus Soil As Directed Within A Lead Of 30 Metres. ( A ) Ordinary Soil 7 ( F ) Chiselling / Wedging Out Rock Where Blasting Is Prohibited.Ii. Hard Rock 8 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 9 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. ( B ) Ordinary Rock 10 Providing And Laying In Position Cement Concrete Of Specified Grade Excludingcost Of Centering And Shuttering - All Work Upto Plinth Level: ( A ) 1:2:4 ( 1 Cement :2 Course Sand :4 Stone Aggregate 20Mm Nominal Size ) 11 Providing And Laying In Position Cement Concrete Of Specified Grade Excludingcost Of Centering And Shuttering - All Work Upto Plinth Level: ( A ) 1:3:6 ( 1 Cement : 2 Course Sand : 6 Stone Aggregate 20Mm Nominal Size ) 12 Providing And Laying Cement Concrete In Retaining Wall, Return Walls, Walls ( Any Thickness ) Including Pilasters, Piers, Columns, Abutments, Pillars, Posts, Plain Window Sills, Sunken Floors, Etc. Up To Floor Five Level Excluding The Cost Of Centering, Shuttering And Finishing : ( B ) 1 : 3: 6 ( 1 Cement :3Course Sand : 6 Stone Aggregate 40Mm ) 13 Providing And Laying In Position Reinforced Cement Concreteexcluding Cost Of Centering And Shuttering , Finishing And Reinforcement In - ( A ) 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate20mm Nominal Size ) 14 Reinforced Cement Concrete Work In Walls Including Attached Pillasters, Columns, Pillers, Posts, Piers, Abutments, Return Walls, Retaining Walls, Struts, Buttresses, String Or Lacing Courses, Fillets Etc. Upto Floor Five Level Excluding Cost Of Centering Shuttering Etc Complete. ( A ) 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate20mm Nominal Size ) 15 ( B ) 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate20mm Nominal Size ) 16 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Window Sills, Stair Cases, Spiral Stair Cases, Cantilevers Upto Floor Five Level Excluding Cost Of Centering Shuttering Etc Complete. ( A ) 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate20mm Nominal Size ) 17 ( B ) 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate20mm Nominal Size ) 18 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Window Sills, Stair Cases, Spiral Stair Cases, Cantilevers Upto Floor Five Level Excluding Cost Of Centering Shuttering Etc Complete. With 1:2:4 ( 1Cement : 2 Coarse Sand :4 Stone Aggregate 20Mm ) 19 Centering And Shuttering Including Strutting, Propping, Etc.And Removal Of Form Works In - ( A ) Foundations, Footings, Bases Of Columns Etc. For Mass Concrete. 20 ( B ) Walls, Etc 21 ( C ) Columns, Pillars, Piers, Abutments, Posts And Struts. 22 ( D ) Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers, Etc. 23 ( E ) Suspended Floors, Roofs, Landings, Shelves And Their Support, Balconies And Chajjaj Etc. 24 ( F ) Staircase Except Spiral Staircase 25 Steel Reinforcement For Rcc Work Including Straighthening, Cutting, Bending, Placing In Position And Binding All Complete. ( B ) Thermo-Mechanically Treated Bars. 26 Half Brick Masonry With First Class Brickin Superstructure Above Plinth Level Upto Floor V Level. ( A ) In Cement Moratar 1:3 ( 1 Cement : 3 Coarse Sand ) 27 Honey-Comb Half Brick Masonry Withfirst Class Brickin Foundation Upto One Storey Above And Below Ground Level Including Curing, Etc. Complete. ( A ) In Cement Mortar 1 : 3 ( 1Cement : 3 Fine Sand ) 28 Regular Coursed Rubble Masonry With Hard Stone In Foundation Upto One Storey Above And Below Ground Level Including Curing, Etc. Complete. ( A ) In Cement Mortar 1 : 3 ( 1Cement : 3 Fine Sand ) 29 ( C ) In Cement Mortar 1 : 6 ( 1Cement : 6 Fine Sand ) 30 Back Filling Behind Abutment, Wing Wall And Return Wall Complete As Per Drawing And Technical Specification. ( A ) Gravelly Material. 31 Providing Ist Class Local Wood Dressed In Frames Of Chaukat For Doors, Windows, Clerestory Windows Fixed In Position. 32 Providing And Fixing 1St Class Local Wood Panelled And Glazed Shutters Using 4Mm Thick Plate Sheet Glass For Doors And Windows Etc. Including M.S. Butt Hinges With Necessary Screws, Etc. Complete. ( B ) 35 Mm Thick. 33 Providing And Fixing 1St Class Teak Wood Panelled And Glazed Shutters Using 4Mm Thick Plate Sheet Glass For Doors And Windows Etc. Including M.S. Butt Hinges With Necessary Screws, Etc. 34 Providing And Fixing 25Mm Thick Mdf Board Greenply Or Equivalent Panelled Shutters For Cupboards Etc. Including Butt Hinges, Handles And Locking Arrangents Complete. ( A ) Using Mdf Board Greenply Or Equivalent. 35 Providing And Fixing Wooden Pelmet With 25Mm Dia Wooden Curtain Rod And Bracket Including Sleeves Etc. Complete ( To Be Fixed On Masonry Or Concrete Work ) ( B ) 1St Class Local Wood ( Ii ) 12Mm Thick 150 Cm Wide Pelmet. 36 Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Upvc Hollow Section Of Size 59X24 Mm And Wall Thickness 2 Mm ( ± 0.2 Mm ) With Inbuilt Edging On Both Sides. The Styles And Rails Mitred And Joint At The Corners By Means Of M.S. Galvanised / Plastic Brackets Of Size 75X220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Inserting Galvanised M.S. Tube Of Size 20X20 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness. The Lock Rail Made Up Of "H" Section, A Upvc Hollow Section Of Size 100X24 Mm And 2 Mm ( ± 0.2 Mm ) Wall Thickness, Fixed To The Shutter Styles By Means Of Plastic / Galvanised M.S. "U" Cleats. The Shutter Frame Filled With A Upvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness. Etc ( B ) 30Mm Thick Shutter 37 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. 38 Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of 80Cm High In Staircase, Etc Consisting Of 75Mm For Rail And Post, 63Mm For Longitudinal Intermediate Rail And 25Mm Of Vertical Section, Spacing 125Mm Interval And As Per Approval Of Engineer-In-Charge. 39 Providing And Fixing Anodised Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Sections / Other Sections Of Approved Make Conforming To Is : 733 And Is : 1285Fixingwith Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up Of Gaps At Junctions, At Top, Bottom And Sides With Required Pvc / Neoprene Gaskets Etc. ( B ) Anodised ( I ) 2 - Track Sliding Windows / Ventilators. 40 ( C ) Powder Coated3 - Track Sliding Windows / Ventilators. 41 Supplying Of Glass Panes At Site. ( A ) 4Mm Thick Plate Sheet Glass. 42 Supplying Of Glass Panes At Site. ( B ) 5Mm Thick Plate Sheet Glass. 43 ( C ) 4Mm Thick Frosted Glass 44 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular And Other Sections Of Approved Make Conforming To Is: 733 And Is : 1285, Anodised Transparent Or Dyed To Required Shade According To Is : 1868. ( Minimum Anodic Coating Of Grade Ac 15 ) , Fixed With Rawl Plugs And Screws Or With Fixing Clips, Or With Expansion Hold Fastners Including Necessary Filling Up Of Gaps At Junctions, At Top, Bottom And Sides With Required Pvc / Neoprene Felt Etc. ( B ) Anodised 45 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Pvc / Neoprene Gasket Required. ( Glazing To Be Paid For Separately ) . ( B ) Anodised 46 ( C ) Powder Coated 47 Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300mm Or More ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is: 15622 Of Approved Make In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20Mm Thick Cement Mortar 1 : 4 ( 1Cement : 4 Course Sand ) Including Pointing The Joints With White Cement And Matching Pigments Etc. Complete. As Per Designed Colour. ( A ) Gloss Finish 48 ( B ) Matt / Antiscratch 49 ( C ) Parking Tiles 50 Providing & Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacture ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Make, In All Colours And Shades, Laid On Bed Of 20Mm Thick Cement Mortar 1 : 4 ( 1Cement:4Course Sand ) , Including The Joints Withwhite Cement And Matching Pigments Etc.Complete.As Per Design Collours. ( A ) Full Body Polish Vitrified ( General ) 51 ( C ) Double Charge 52 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To E Specified By The Manufacaturer ) , Of Approved Make, In All Colours, Shades Wxcept Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12Mm Thick Bed Of Cemunt Mortar 1:3 ( 1Cemeny :3 Coarse Sand ) And Jointing With Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 53 Providing And Fixing Bright Finished M.S Oxidised Two Lever Mortise Door Lock With Necessary Screws, Etc. Complete. ( B ) Knob Type. 54 Providing And Fixing Brass Sliding Door Bolts ( Aldrops ) Bright Finished With Nuts And Screws Etc. Complete. ( A ) 300 X 16 Mm 55 Providing And Fixing Brass Handles With Necessary Screws, Etc. Complete. ( A ) 150Mm 56 Providing And Fixing Alluminium Tower Bolts ( Socket Bolts ) Anodised Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete. ( A ) 250 Mm 57 Providing And Fixing Curtain Rod With Necessary Screws & Fittings, Etc. Complete. ( A ) Bright Finished 58 Providing And Fixing Curtain Rope Hook With Necessary Screws , Etc. Complete. ( A ) Brass 59 Supplying, Fitting And Fixing Calcium Silicate Board Ceiling With Nescessary Screws Etc. Complete Excluding Frame Work Of Base And Beading. ( Hilux Or Equivalent ) 60 Providing And Fixing G.I Steel Frame Works For Ceiling Lining Consisting Of Battens 50X25mm Fixed Over Plugs Embedded In Wall With Necessary Screws, Etc. Complete. 61 Prov & Fixing Water Closet ( A ) Orissa Pan ( I ) White 62 Providing And Fixing Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : ( A ) Orrisa Pan With Integral Type Foot Rests ( I ) White 63 Providing And Fixing White Vitreous China Wash Basin Standard Of Parryware / Hindware / Cera And Equivalent Make With R.S. Or C.I. Brackets, 15Mm C.P. Brass Pillar Taps, C.P. Brass Chain With Rubber Plugs, 32Mm C.P. Brass Waste Of Standard Pattern, 32Mm C.P. Brass Traps And Union Complete Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required. ( A ) Vitreous China Wash Basin Size 630X450 Mm With Single 15 Mm C.P. Brass Pillar Taps ( I ) White 64 Providing And Fixing Vitreous China Tall Pedestal Of Parryware / Hindware / Cera And Equivalent Make For Wash Basin Completely Recessed At The Back For The Reception Of Pipes And Fittings. ( I ) White 65 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Ofapproved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With Cp. Brass Screws And Washers Complete. 66 Providing And Fixing Anodised Aluminium Towel Rail Complete With Brackets Fixed To Wooden Wooden Cleats With Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quality And Colour. ( A ) 750X20mm Size. 67 Providing And Fixing Liquid Soap Container With C.P Brass Lidand Brackets Fixed To Wooden Cleats With The Same Materials Etc Complete. ( A ) ( I ) Glass Container With C.P. Lid And Brackets. 68 Providing And Fixing On Wall Face Swrpvc Soil, Waste And Vent Pipes Including Jointing With Rubber Lubricant / Cement Solvent Complete. ( A ) 110Mm Dia 69 ( B ) 75Mm Dia 70 Providing And Fixing Swrpvc Plain Bend Of Required Degree ( 87.50° ) Including Jointing With Rubber Lubricant / Cement Solvent Complete. ( A ) 110Mm Dia 71 ( B ) 75Mm Dia 72 Providing And Fixing Swrpvc Plain Bend Of Required Degree ( 45° ) Including Jointing With Rubber Lubricant / Cement Solvent Complete. ( A ) 110Mm Dia 73 ( B ) 75Mm Dia 74 Providing And Fixing Swrpvc Plain Bend With Access Door Of Required Degree Including Jointing With Rubber Lubricant / Cement Solvent Complete. ( A ) 110Mm Dia Swrpvc Bend With Access Door. 75 ( B ) 75Mm Dia Swrpvc Bend With Access Door. 76 Providing And Fixing Single Equal Swrpvc Plain Junction Of Required Degree ( T-Junction ) ( A ) 110Mmx110mmx110mm Dia 77 ( B ) 75X75x75mm. 78 Providing And Fixing Ventilation Cowl Including Jointing With Rubber Lubricant / Cement Solvent Complete. ( A ) 110Mm Swrpvc Vent Cowl 79 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. ( A ) Sintex Or Quivalent 80 Providing And Fixing G.I. Pipe Complete With G.I. Fitting Including Trenching And Refilling Etc. ( External Work ) . ( C ) 25Mm Dia Nominal Bore. 81 Providing And Fixing Brass Ball Valve Of Approved Quality Complete With Plastic Floats Complete. ( C ) 25Mm Nominal Bore 82 Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards. ( A ) 15Mm Nominal Bore 83 Providing And Fixing Cpvc Pipes Complete With Cpvc Fitting For Water Supply Including Clamps At One Metre Spacing, Cutting And Making Good The Walls Etc. ( Internal Works ) . Exposed On Walls. ( A ) 15Mm Dia Nominal Bore 84 ( B ) 20Mm Dia Nominal Bore 85 Extra For Concealed In Brick And Rcc Works By Making Chases Upto 7.5X7.5Cm In Walls And Making Good The Same After Housing Pipes, Etc. 86 Making Connection Of Astral Cpvc Pipes Distribution Branch By Providing And Fixing Equal Tee With Jointing, Testing Complete Including Cutting And Making Good Etc. ( B ) 20Mm Dia Nominal Bore. 87 Making Connection Of Astral Cpvc Pipes Distribution Branch By Providing And Fixing Brass Fpt Tee With Jointing, Testing Complete Including Cutting And Making Good Etc. ( B ) 20 X 20 X 15 Mm 88 Making Connection Of Astral Cpvc Pipes Distribution Branch By Providing And Fixing Elbow 90° With Jointing, Testing Complete Including Cutting And Making Good Etc. ( A ) 15Mm Dia 89 ( B ) 20Mm Dia 90 Making Connection Of Astral Cpvc Pipes Distribution Branch By Providing And Fixing Reducing "L" Ebow 90O With Jointing, Testing Complete Including Cutting And Making Good Etc. ( A ) 20X15mm 91 Making Connection Of Astral Cpvc Pipes Distribution Branch By Providing And Fixing Male Adaptor ( P ) With Jointing, Testing Complete Including Cutting And Making Good Etc. ( B ) 20Mm Dia 92 Making Connection Of Astral Cpvc Pipes Distribution Branch By Providing And Fixing Union Socket With Jointing, Testing Complete Including Cutting And Making Good Etc. ( A ) 15Mm Dia 93 ( B ) 20Mm Dia 94 Providing And Fixing Cpvc Ball Valve / Globe / Stop & Waste Valve / Boiler Drain Etc. Complete. ( A ) 15Mm Dia 95 ( B ) 20Mm Dia 96 Providing And Placing In Position Electric Water Pump Of Approved Manufacture Including Connections To G.I Pipes Etc. Complete With Accessories. ( B ) 750 Watts 97 Applying Double Coated Pidifin-2K On The Surface Of Cement Concrete For Prevention Of Water Infiltration And Dampness In Water Tanks, Basement, Terraces, Etc. ) @1.85Kg Per Sqm. 98 Extra For Providing And Mixing Water Proofing Chemical ( Plastocrete Or Equivalent Chemical ) In Plain And Reinforced Cement Concrete Work 1:2:4, @ 2% By Weight Of Cement. 99 12Mm Cement Plaster 1 : 3 ( 1 Cement : 3 Fine Sand ) . 100 12Mm Cement Plaster 1 : 5 ( 1 Cement : 5 Fine Sand ) . 101 15Mm Cement Plaster 1 : 4 ( 1 Cement : 4 Fine Sand ) . 102 20Mm Cement Plaster 1 : 4 ( 1 Cement : 4 Fine Sand ) . 103 20Mm Cement Plaster 1 : 3 ( 1 Cement : 3 Fine Sand ) 104 Extra For Providing And Mixing Water Proofing Materials In Proportion Recommended By Manufacturer In - ( A ) 12Mm Cement Plaster 1 : 3 ( 1 Cement : 3 Fine Sand ) . 105 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete 106 Applying Priming Coat With Ready Mixed Primer Of Approved Brand And Manufacture On Plaster Surface. ( A ) Ready Mix White Primer. 107 Applying Priming Coat With Ready Mixed Primer Of Approved Brand And Manufacture On Wood Work And Plywood Complete. 108 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shades On New Work ( Two Or More Coats ) . ( A ) General Quality 109 Wall Painting With Interior Emulsion Paint Of Approved Brand And Manufacture On New Work ( Two Or More Coats ) To Give An Even Shade. ( B ) Premium Interior Emulsion Like Velvet Touch Luxol Silk Etc. 110 Finishing Walls Withexterior Emulsion Of Required Shade On New Work ( Three Or More Coats ) To Give An Even Shade. ( B ) Premium Exterior Emulsion Like Weather Shield, Weathercote Etc. 111 Carriage By Mechanical Transport Including Loading, Unloading And Stacking Etc. ( B ) Earth For A Lead Of 5Kms 112 Internal Electrificationfor Light Points, Ceiling Fan Points, Wall Fan Points, Etc., Gr-I Wiring In Looping System With Pvc Sheathed Standard Copper Conductors / Wires As Per Is:694 ( 1990 ) And Halogen Free Flame Retardant ( Hffr ) 1100V Graded Copper Flexible Wire Strandard Copper 1.5Sqmm Running Inside Pvc Casing & Capping ( Gr-I ) 20X12mm Fixed Surface On The Wall / Ceiling / Floor As Per Convenience Including Junction Box Having Required Number Of Ways From Control Switch To The Points, Etc, As Required :-1. To Light Pointsa ) Very Short Point 113 B ) Short Point 114 C ) Medium Point 115 D ) Long Point 116 For Power Plug / Socket Point 15 / 16Amps. ( Modular Type ) Wiring In Looping System With Pvc Sheathed Standard Copper Conductors / Wires As Per Is:694 ( 1990 ) And Halogen Free Flame Retardant ( Hffr ) 1100V Graded Copper Flexible Wire Stranded Copper 4.0Sqmm Running Inside Pvc Casing & Capping ( Gr-I ) 30X12mm Fixed Surface On The Wall / Ceiling / Floor As Per Convenience Including Junction Box Having Required Number Of Ways From Db To The Power Plug / Socket 15 / 16A Points, Etc, As Required :-E ) Very Long Point 117 For Power Plug / Socket Point 20 / 32Amps. ( Modular Type ) Wiring In Looping System With Pvc Sheathed Standard Copper Conductors / Wires As Per Is:694 ( 1990 ) And Halogen Free Flame Retardant ( Hffr ) 1100V Graded Copper Flexible Wire Straned Copper 4.0Sqmm Running Inside Pvc Casing & Capping ( Gr-I ) 30X12mm Fixed Surface On The Wall / Ceiling / Floor As Per Convenience Including Junction Box Having Required Number Of Ways From Db To The Power Plug / Socket 20 / 32A Points, Etc, As Required :-E ) Very Long Point 118 For Calling Bell Point ( Modular Type ) Wiring In Looping System With Pvc Sheathed Standard Copper Conductors / Wires As Per Is:694 ( 1990 ) And Halgen Free Flame Retardant ( Hffr ) 1100V Graded Copper Flexible Wire Stranded Copper 1.5Sqmm Running Inside Pvc Casing & Capping ( Gr-I ) 30X12mm Fixed Surface On The Wall / Ceiling / Floor As Per Convenience Including Junction Box Having Required Number Of Ways From Control Bell Push Switch To The Bell Point, Etc, As Required :-E ) Very Long Point 119 Main To Sub-Main Wiring Grade-1 Surface ( Single Phase Two Wires ) Wiring In Parallel System With Pvc Sheathed Standard Copper Conductors / Wires As Per Is:694 ( 1990 ) And Halogen Free Flame Retardant ( Hffr ) 1100V Graded Copper Flexible Wire Stranded Copper Of Different Sizes As Mentioned Below Running Inside Pvc Casing & Capping ( Gr-I ) Of Appropriate Size Fixed Surface On The Wall / Ceiling / Floor As Per Convenience Including Junction Box Having Required Number Of Ways From Main To Sub-Main / Db, Sub-Main / Db To Switch Boards Etc, As Required :-A ) 2X2.5Sqmm Copper Conductor / Cable + 1X2.5Sqmm Earth Wire 120 B ) 2X4.0Sqmm Copper Conductor / Cable + 1X4.0Sqmm Earth Wire 121 C ) 2X6.0Sqmm Copper Conductor / Cable + 1X6.0Sqmm Earth Wire 122 Main To Sub-Main Wiring Grade-1 Surface ( Three Phase Four Wires ) Wiring In Parallel System With Pvc Sheathed Standard Copper Conductors / Wires As Per Is:694 ( 1990 ) And Flame Retardant Low Smoke & Halogen ( Fr-Lsh ) 1100V Graded Copper Flexible Wire Stranded Copper Of Different Sizes As Mentioned Below Running Inside Pvc Casing & Capping ( Gr-Ii ) Of Appropriate Size Fixed Surface On The Wall / Ceiling / Floor As Per Convenience Including Junction Box Having Requi-Red Number Of Ways From Main To Sub-Main / Db, Sub-Main / Db To Sdb, Sdb To Switch Boards Etc, As Required :-D ) 4X 10Sqmm Copper Conductor / Cable + 2X10sqmm Earth Wire 123 E ) 4X 16Sqmm Copper Conductor / Cable + 2X16sqmm Earth Wire 124 F ) 4X 25Sqmm Copper Conductor / Cable + 2X16sqmm Earth Wire 125 Laying Of Ug / Xlpe Cablessupplying, Unrolling & Laying Of Different Sizes Of Under Ground Cable Xlpe In The Existing Exvacuated Earth, Masonry Duct, Rcc / Hume / Metal Pipe, Etc, Including Commissioning, Etc.08 ) 35Sqmm 3.5Core As Per Is:1554 Part-Ii Xlpe / Pvc Power Alluminium Cables 126 Cable Jointing Kitsupplying, Fitting & Commissioning Of Cable End Joint For Under Ground Cable Xlpe Including Commissioning, Etc.05 ) Xlpe / Pvc Power Cable Termination End Jointing Kit 25 / 35Sqmm 127 Light Points, Ceiling Fan Points, Exhaust Fan Points, Etc. ( Modular Type ) Wiring In Looping System With Pvc Wire Sheathed Standard Copper Conductor / Wires As Per Is:694 ( 1990 ) And Flame Retardant Low Smoke & Halogen ( Fr-Lsh ) , 1100 Voltage Graded Copper Flexible Wire Stranded Copper 1.5Sqmm Running Inside Pvc Cassing & Caping ( Grade-Ii ) 20Mm Dia.Fixed Surface On The Wall / Ceiling / Floor As Per Convenience Including Junction Box Having Required Number Of Ways From Control Switch To The Light Points, Etc. As Required :-1. To Light Pointsa ) Very Short Point 128 B ) Short Point 129 C ) Medium Point 130 D ) Long Point 131 Light Plug / Socket Point 5 / 6 Amperes ( Modular Type ) Wiring In Looping System With Pvc Wire Sheathedstandard Copper Conductor / Wires As Per Is:694 ( 1990 ) And Flame Retardant Low Smoke & Halogen ( Fr-Lsh ) 1100 Voltage Graded Copper Flexible Wire Stranded Copper 2.5 Sqmm Running Inside Pvc Casing & Capping ( Gr-Ii ) 20X12mm Fixed, Surface On The Wall / Ceiling / Floor As Per Convinience Including Junction Box Having Required Numbers Of Ways From Db To The Light Plug / Socket 5 / 6 Amps Point Etc. As Required :- B ) Short Point 132 C ) Medium Point 133 D ) Long Point 134 Power Plug / Socket Point 15 / 16 Amperes ( Modular Type ) Wiring In Looping System With Pvc Wire Sheathedstandard Copper Conductor / Wires As Per Is:694 ( 1990 ) And Flame Retardant Low Smoke & Halogen ( Fr-Lsh ) 1100 Voltage Graded Copper Flexible Wire Stranded Copper 4.0 Sqmm Running Inside Pvc Casing & Capping ( Gr-Ii ) 30X12mm Fixed, Surface On The Wall / Ceiling / Floor As Per Convinience Including Junction Box Having Required Numbers Of Ways From Db To The Power Plug / Socket 15 / 16A Point Etc. As Required :-E ) Long Point 135 E ) Long Point 136 Lighting Fixtures And Fanssupplying And Fixing Of Angle Holder Fancy Type Including Connections, Etc, As Required. 137 Supplying, Fitting And Fixing Of Calling Bell Musical Suitable For Ac / Dc Single Phase 230Volts Completed As Required. 138 Installation, Testing And Commissioning Of Pre-Wired Fl Fittings / Led Batten Fittings Of All Types With Accessories And Tubes, Etc, Directly On The Wall / Ceiling Including Connection With 1.5Sqmm Pvc Insulated Copper Conductor Single Core Cable, Etc, As Required. 139 Installation, Testing And Commissioning Of Ceiling Fan And Regulator Including Wiring The Down Rod Of Standard Length ( Up To 30Cm ) With 1.5Sqmm Pvc Insulated Copper Conductor Single Core Cable, Etc, As Required. 140 Installation Ofexhaust Fan Up-To 450 Mm Sweeps In The Existing Opening, Including Makingholes To Suit The Size Of The Above Exhaust Fan, And Making Good The Damage, Connection, Testing And Commissioning Etc, As Required. 141 Supplying Of Pre-Wired Ftl / Led Fittings With Neccesary Accessories And Tubes, Etc, As Required.1 ) Comet Led Round Surface Panel 12W 6500K 142 2 ) Comet Led Round Surface Panel 15W 6500K 143 3 ) Comet Led Round Surface Panel 18W 6500K 144 4 ) Comet Led Round Surface Panel 24W 6500K 145 5 ) Jeta Compacto 30W Led Ip65 6500K 146 6 ) Tled Fitting Astraline Plus 24W 147 Supplying Of Pre-Wired Ceiling Fan As Per Is:374 ( 1979 ) In A Set Including Standard Down Rod, Canopy, Ac Ceiling Fan Machine, Etc, In Complete As Follows :1 ) Ceiling Fan Fabia Platinum Antique Brused Nidkel 1200Mm Sweeps 3-Blades Isi Marked. 148 Supplying Of Pre-Wired Bracket Wall Mounted Fan As Required.1 ) Bracket Wall Mounted Fan 400Mm Sweeps Helix With Remote Isi Marked 149 Supplying Of Exhaust Fan As Required.1 ) Exhaust Fan Heavy Duty 300Mm Sweeps 900 / 1400 Rpmisi Marked ( Usha / Havells / Equivalent ) 150 Supplying And Fitting Of All Types Of Cfls, Led Lamps, Etc, In Complete As Required.1 ) Led Adore5w B22 Cdl 6500K 3-Star Lamp 151 2 ) Led Adore7w B22 Cdl 6500K 3-Star Lamp 152 3 ) Led Adore 9W B22 Cdl 6500K 5-Star Lamp 153 Panel Board, Mdb, Sdb & Switch Boardsload Bank Panel Board45 ) Supplying, Fitting & Fixing Of Load Bank Panel Board 6-Ways Suitable With 250 Mccb Aa Frame Incomer , Bus Bar, Neutral Links, In A Sheet Steel Enclosureacrylic Cover Phosphatised Powder Paintedconforms To Is:8623, Iec:60439 With Metering Module With Mccbs 415 Volts, 50 Hz, Ac On Surface / Recess Including Inter-Connection, Painting Etc, As Required And Out Going 125A Mccb G-Frame Fp Complete In A Set With Digital Metering Modules Double Door ( Havells / Hpl ) 154 101 ) Add On Incoming Change Over Switch For Panel Board I / C 250 A F1 ( Havells / Hpl ) 155 04 ) Supplying And Fixing Of Different Ratings Three / Four Poles Automatic Transfer Switch ( Ats ) 315 Amps Fourpoles ( Conforms To Iec:60947-1 Three / Four Pole Ac-31A 50Hz, 415V Automatic / Manual With Inbuilt Time Delaywith Enclosure For Change Over Switch In The Existing Panel Board / Distribution Boards To Be Incorporated With Required Ac Voltages Including Testing, Calibrating, & Commissioning Etc, As Required;- ( To Be Incorporated With The Above Panel On Change Over Add On ) 156 04 ) Supplying And Fixing Offour Poles ( Fp ) -315A Fp Instaline Phase Corrector Unit Automatic / Manual With Inbuilt Time Delay50hz, 415Vwith Enclosure In The Existing Panel Board / Distribution Boards To Be Incorporated Withrequired Acvoltages Including Testing, Calibrating, & Commissioning Etc, As Required;- ( To Be Incorporated In The Above Panel Board ) 157 Mcb Distribution Boardsupplying, Fitting And Fixing Different Ways Mcb Distribution Boards Double Door, Single / Three Phase With Cable In Sheet Steel Phosphatised Power Painted Mcb Dbs With Busbar, Neutral Link, Earth Bar And Din Rail Conforms To Is:13032, Is:8623, Bs:5486, 240V 50Hz Ac On Surface / Recess Including Inter-Connection, Painting, Etc As Required.10 ) 8-Ways Mcb Db Sp&N D / D Acrylic Door 158 23 ) 4-Ways ( 4+12 ) Mcb Db Tp&N D / D Acrylic Door 159 Mcbs Sp / Sp&N / Dp / Tp / Tp&N / Fpsupplying And Fixing Of All Types And Ratings Mcbs 240 / 415V 50Hz, Ac Supply In The Existing Mcb Db Complete With Connection, Testing And Commissioning, Etc., As Required.01 ) 6 - 32Amps Sp Mcb B-Series 160 16 ) 32Amps. Dp Mcbc-Series 161 17 ) 40 Amps. Dp Mcbc-Series 162 13 ) 6 - 32Amps Sp Mcb C-Series 163 24 ) 50 / 63 Amps" Rating, Fp, Mcb B- Series 164 Supplying And Fixing Of Switch Boards ( Modular Type Gr-Ii ) Supplying, Fitting And Fixing Of Modular Switch Boards Gr-Ii Of The Following Sizes / Modules On Surface / Recess Including Pvc Boxes, Modular Plate And Neccesary Switches, Plug / Socket And Fan Regulators, Etc, , With Neccesary Painting If Required.A ) One Module01 ) 1S 165 04 ) 1S ( Bell Push ) 166 B ) Two Module13 ) 2S 167 C ) Three Module33 ) 3S 168 38 ) 1S + 1Soc 169 40 ) 1S + 1 Soc16a 170 42 ) 1S 25A + 1Soc 16A 171 D ) Four Module53 ) 4S 172 56 ) 2S + 1Soc 173 E ) Six Module91 ) 3S + 1Soc + 1Bkp 174 F ) Eight Modules158 ) 3S + 1 Soc+1R+1Bkp 175 91 ) 4S + 1 Soc+1R 176 95 ) 4S + 1Soc 177 F ) Eight Module148 ) 6S + 1Soc 178 158 ( A ) 4S + 1Soc + 1R 179 G ) Twelve Module273 ) 6S + 1Soc + 1R + 2Bkp 180 Earthing And Lightning Conductorearthing And Loop Earthing22 ) Advance Maintenance Free Earthing 78Mm Dia 3Mtr Length And 3.6Mm Wall Thickness Copper Bonded Thick Wall Electrode With 1 Bag Of Back Filling Compound. 181 36 ) Extra For Using Back Filling Compound For Gi Or Copper Maintenance Free Electrode As Required Sbe Gold Back Fill Compound 25Kgs Per Bag 182 45 ) Providing And Laying Of Earth Connection From Earth Electrode With 4.00Mm Dia Copper Wire In 15Mm Dia Gi Pipe Form Earth Electrode As Required. ( 8Swg Copper Wire = 4Mm Dia. ) 183 47 ) Providing And Fixing Of 20Mmx3mm Copper Strip On Surface Or Recess For Connection, Etc As Required ( 1.0Kg / Mtr ) 184 Lightning Conductor08 ) Providing And Fixing Of Ese Type Lightning Arrestor Pdc - 6.3 ( Dpdc 6.3 ) With Non Electric Ese ( Early Steamer Emmision ) Standardised According To Norms Une21.186 And Npc17.102 Duly Tested And Certified By Cpri Bangalore, Having Coverage Area Of 63Mtr Dia. Lightning Charge Capacity Of 100Ka And 43Micro Second Delay ( Docksun / Equivaleny ) 185 10 ) Providing And Fixing Of Stainless Stell Pole For Ese Type Lightning Arrestor 50Mm 3Mtrs Long Made Of Ss-304 Material With Base Plate To Mount Lightning Arrestor ( Docksun / Equivalent ) In Complete. 186 11 ) Providing And Fixingof Lightning Even Counter / Lighning Strike Counter ( Can Be Fitted Inside The Box On Request ) 1500 Amps Sensivity Mechanical ( Doksun / Equivalent ) 187 13 ) Providing And Fixing Of Down Conductor Pure Copper Cable Rubber Insulated Connecting Cable 50Sqmm. 188 Calling Bell Point ( Modular Type ) Wiring In Looping System With Pvc Wire Sheathedstandard Copper Conductor / Wires As Per Is:694 ( 1990 ) & Flame Retardant Low Smoke & Halogen ( Fr-Lsh ) 1100 Voltage Graded Copper Flexible Wire Stranded Copper 1.5 Sqmm Running Inside Pvc Cassing & Caping ( Gr-Ii ) Of Different Sizes Fixed Surfaceon The Wall / Ceiling / Floor As Per Convinience Including Junction Box Having Required Numbers Of Ways From Control Bell Push Switch To The Light Point Etc As Required :- C ) Medium Point 189 Main To Sub-Main Wiring ( Single Phase Two Wires ) :-Wiring In Parallel System With Pvc Wire Sheathedstandard Copper Conductor / Wires As Per Is:694 ( 1990 ) And Flame Retardant Low Smoke & Halogen ( Fr-Lsh ) 1100 Voltage Graded Copperflexible Wire Stranded Copper Of Different Sizes As Mentioned Below Running Inside Pvc Casing & Capping ( Gr-Ii ) Of Appropriate Sizes Fixed, Surface Onthewall / Ceiling / Floor As Per Convinience Including Junction Box Having Required Numbers Of Ways From Main To Sub-Main / Db, Sub-Main / Db To Sdb, Sdb To Switch Boards As Required:-A ) 2X2.5 Sqmm Copper Conductor / Cable+1X2.5Sqmm Earth Wire 190 B ) 2X4.0 Sqmm Copper Conductor / Cable+1X4.0Sqmm Earth Wire 191 B ) 2X6.0 Sqmm Copper Conductor / Cable+1X6.0Sqmm Earth Wire 192 Fixing And Erection Of Wall Bracket / Ceiling Fittings Of All Sizes And Shapes Containing Up To Two Gls / Pls / Cfl / Led Lamps Per Fitting, Complete With All Accessories Including Connection, Etc.As Required. 193 Supplying Of Pre-Wired Led Fittingswith Necessary Accessories And Tubes Etc, In Complete.1 ) E-Lite Led Pride Plus 18W 194 2 ) Octane Led Panel Round 15W Led 6500K 195 2 ) Octane Led Panel Round 15W Led 6500K 196 Supplying Of Pre-Wired Ceiling Fan As Per Is:374 ( 1979 ) In A Set Including Standard Down Rod, Canopy, Ac Ceiling Fan Machine.1 ) Ceilling Fan Orion Antique Brushed Nickel 1200Mm Sweep 3 Blades ( Havells / Usha ) 197 Supplying And Fitting Of All Types Of Cfls, Tl Type Fc Tubes, Fp-L / Pll Tubes, Etc., In Complete As Follows :-A ) Led Adore 10W B22 / B27 3 Star Lamp 198 B ) Led Adore 9W B22 / B27 3 Star Lamp 199 Earthing And Loop Earthingearthing And Loop Earthing17 ) Advance Maintenance Free Earthing 68Mm Dia, 2M Length And 3.6Mm Wall Thickness Copper Bonded With 1Bags Of Back Filling Compound Electrode. 200 37 ) Extra For Using Back Filling Compound For G.I Or Copper Maintenance Free Electrode As Required Ground Improving Material / Back Fill Compound 25 Kgs 201 47 ) Providing And Fixing Of 20Mmx3mm Copper Strip On Surface Or Recess For Connection Etc, As Required ( 1.0Kg / Mtr ) 202 Lightning Conductor05 ) Providing And Fixingof Ese Type Lightning Arrestor Pdc 3.3 ( Dpdc 3.3 ) With Non Electric Ese ( Early Steamer Emission ) Standardized According To Norms Une 21.186 And Npc 17.102 Duly Tested And Certified By Cpri Bangalore, Having Coverage Area Of 63M Diameter Lightning Charge Capacity 60 Ka And 25 Micro Second Delay ( Doksun / Equivalent ) 203 09 ) Providing And Fixing Of Stainless Steel Pole For Ese Lightning Arrestor 50M 2 Meter Long Made Of Ss-304 Material With Base Plate To Mount Lightning Arrestor ( Doksun ) In Complete. 204 13 ) Providing And Fixing Of Down Conductor Pure Copper Cable Rubber Insulated Connecting Cable 50 Sqmm 205 Metal Clad Switch Fuse Units With Rewirable Sfuproviding And Fixing Of Different Ratings Metal Clad, Dp Switch Fuse Unit ( Sfu ) 415 / 500V With Rewireable Porcelein Fuse Unit Including Holes On The Boards, Connections, Earthing The Body, Etc., As Required:-07 ) 63 Amps Metal Clad Switch Fuse Unit Isi Marked With Isi Marked Re-Wireable Porcelein Fuse Unit Dp Category "A" 206 Lumpsum - Centage Chargescontingency For Future Unforeseen Expenditure Related To The Works 207 Provision For Effluent Treatment Plant 208 Provision For Quality Control Of The Work Viz. For Supervision And Monitoring Of The Work 209 Provision For External Water Service Connection 210 Provision For Single Phase Service Connection
|