Tender For Implementation Of Scada And Dms / Oms Works In Gurugram Revamped Distribution Sector Scheme ( Rdss ) In Dhbvn---2 Installation, Testing And Commissioning Cost Tointegrate Entire Scada & It ( Relevant To Scada ) Infrastructure 3 Integration With Legacy Applications & Data Migration 4 Training For Employees ( Refer Form -9 ) 5 Form-2 : Scada / Dms Control Centre 6 C1 : Server / Workstation Hardware 7 Scada Server 8 Dms Server 9 Oms Server 10 Fep Server With Interface Switches 11 Isr Server 12 Nms Server 13 Dts Server 14 Other Active Devices ( Kindly Specify Item Along With Make And Model ) 15 Developmental Server 16 Commnuicationserver 17 Web / Directory Server ( Icluding Web / Network Security Software ) 18 Sms Gaterway 19 Workstation With Dual Tft Monitors ( S / S Monitoring ) 20 Workstation With Dual Tft Monitors ( Network Monitoring ) 21 Remote Vdus With One Tft Monitors 22 Developmental Console With One Tft 23 Dts / Workstation Console Withdual Tfts 24 Dlp / Led Based Video Projection System With 3X4 Module Configuration With Each Module At Least 70" Diagonal With Common Projector 25 Storage And Backup Devices 26 External Raid Mass Storage Device ( For 24 Months Online Backup ) 27 Exteranl Dat Drive 28 Switches 29 Layer Ii Switch ( Scada / Dms Lan ) 30 Layer Ii Switch ( Planning & Development System Lan ) 31 Router 32 Router For Interfacing It System & Scada / Dms Dr Centre 33 Router At Remote Vdu 34 Security System ( Dmz ) 35 Web Server With Load Balancing 36 Mail Server 37 Router 38 Firewall & Network Ids / Ips 39 Layer Ii Switch 40 Other Active Devices 41 Gps Timesynchronisation System 42 Time, Day & Date Digital Displays 43 Printer 44 Color Inkjet Printer 45 B / W Laser Printer 46 Workstation With Three Tft Monitors 47 A3 Multi Function Colour Printer 48 C2 :Software For Control Center 49 Scada Software 50 Isr Software 51 Dms Software 52 Oms Software 53 Dts Software 54 Developmental Software 55 Network Management Software 56 Rdbms Package 57 Gis Adaptor / Engine For Importing Data From Gis System Under It System 58 Any Other Software To Meet Functional / Performance Requirement Ofmts ( Kindly Specify Item Along With Make And Model ) 59 C3: Mandatory Sparesmax5% Of C1 60 Mandatory Spares 61 Form-3 : Dr / Control Center 62 D1 : Server / Workstation Hardware 63 Scada Server 64 Dms Server 65 Oms Server 66 Fep Server With Interface Switches 67 Isr Server 68 Nms Server 69 Dts Server 70 Other Active Devices ( Kindly Specify Item Along With Make And Model ) 71 Developmental Server 72 Commnuicationserver 73 Web / Directory Server ( Icluding Web / Network Security Software ) 74 Sms Gaterway 75 Workstation With Dual Tft Monitors ( S / S Monitoring ) 76 Workstation With Dual Tft Monitors ( Network Monitoring ) 77 Remote Vdus With One Tft Monitors 78 Developmental Console With One Tft 79 Dts / Workstation Console Withdual Tfts 80 Dlp / Led Based Video Projection System With 3X4 Module Configuration With Each Module At Least 70" Diagonal With Common Projector 81 Storage And Backup Devices 82 External Raid Mass Storage Device ( For24months Online Backup ) 83 Exteranl Dat Drive 84 Switches 85 Layer Ii Switch ( Scada / Dms Lan ) 86 Layer Ii Switch ( Planning & Development System Lan ) 87 Routers 88 Router For Interfacing It System & Scada / Dms Dr Centre 89 Router At Remote Vdu 90 Security System ( Dmz ) 91 Web Server With Load Balancing 92 Mail Server 93 Router 94 Firewall & Network Ids / Ips 95 Layer Ii Switch 96 Other Active Devices 97 Gps Timesynchronisation System 98 Time, Day & Date Digital Displays 99 Printers 100 Color Inkjet Printer 101 B / W Laser Printer 102 Workstation With Three Tft Monitors 103 A3 Multi Function Clour Printer 104 D2 : Software For Control Center 105 Scada Software 106 Isr Software 107 Dms Software 108 Oms Software 109 Dts Software 110 Developmental Software 111 Network Management Software 112 Rdbms Package 113 Gis Adaptor / Engine For Importing Data From Gis System Under It System 114 Any Other Software To Meet Functional / Performance Requirement Ofmts ( Kindly Specify Item Along With Make And Model ) 115 D3 : Mandatory Sparesmax5% Of D1 116 Mandatory Spares 117 Form-4 : Rtu Equipments 118 E1 : Rtu 119 Rtu Base Equipment Comprising Panels, Racks, Sub-Racks, Power Supply Modules, Cpu, Interfacing Equipment, Required Converters & All Other Required Items / Accessories Including Complete Wiring For All Modules For Locations Mentioned At Vol Vi 120 Multifunctions Transducers 121 Contact Multiplying Relays ( Cmrs ) 122 Heavy Duty Relays For Control 123 Dummy Breaker Latching Relays 124 Transformer Transducers 125 Single Tft Pc Forldms With 2Kva Ups 126 Network Switches ( 24 Ports ) -Iec- 61850 Compliant Ethernet Switch With Industrial Networking Capability As Per Ieee 802.1 For Ethernet Redundancy. 127 Network Switches ( 48 Ports ) -Iec- 61850 Compliant Ethernet Switch With Industrial Networking Capability As Per Ieee 802.1 For Ethernet Redundancy. 128 L2 Industrial Grade Managed Switch With 8 X Sfp Slots ( 1000Mbits / Sec ) And 4 X ( 100 Mbits / Sec ) Twisted Pair ( Tx ) / Rj45 Along With Supply Of Necessary Patch Chords And Adaptors 129 L2 Industrial Grade Managed Switch With 12 X Sfp Slots ( 1000Mbits / Sec ) And 4 X ( 100 Mbits / Sec ) Twisted Pair ( Tx ) / Rj45 Along With Supply Of Necessary Patch Chords And Adaptors 130 L3 Industrial Grade Managed Switch With 48 X Sfp Slots ( 1000Mbits / Sec ) And8 X ( 100 Mbits / Sec ) Twisted Pair ( Tx ) / Rj45 Along With Supply Of Necessary Patch Chords And Adaptors 131 Fibre Optic Distribution Panel With 12 Ports Along With Supply Of Necessary Patch Chords And Adaptors 132 Fibre Optic Distribution Panel With 16 Ports Along With Supply Of Necessary Patch Chords And Adaptors 133 Fibre Optic Distribution Panel With 20 Ports Along With Supply Of Necessary Patch Chords And Adaptors 134 Fibre Optic Distribution Panel With 24 Ports Along With Supply Of Necessary Patch Chords And Adaptors 135 Fibre Optic Distribution Panel With 96 Ports Along With Supply Of Necessary Patch Chords And Adaptors 136 E2: Software For Ldms 137 Ldms Software 138 E3 : Test Euipment For Rtu 139 Rtu Database Configuration & Maintenance Software Tool 140 Master Station Cum Rtu Simulator & Protocol Analyser Software Tool 141 Laptop Pc For Above Software Tools Along Withinterfacing Hardware Including Hub 142 E4 : Mandatory Sparesmax5% Of E1 143 Mandatory Spares 144 Form-5 : Frtu Equipments 145 F1 : Frtus 146 Mini Pole Mounted Frtu Base Equipment Along With Enclosure Suitable To Work In Open Environment ( Adequate Protection From Water & Dust ) , Racks, Sub-Racks, Power Supply Modules With Power Backup , I / O Modules, Cpu, Interfacing Equipment, Required Converters & All Other Required Items / Accessories Including Complete Wiring For All Modules For Locations Mentioned At Vol Vi 147 Contact Multiplying Relays ( Cmrs ) 148 Heavy Duty Relays For Control 149 Multifunction Trnasducer 150 Any Other Software To Meet Functional / Performance Requirement Ofmts ( Kindly Specify Item Along With Make And Model ) 151 Network Switches ( 12 Ports ) 152 F2 : Test Euipment For Frtu 153 Frtu Database Configuration & Maintenance Software Tool 154 Master Station Cum Frtu Simulator & Protocol Analyser Software Tool 155 Laptop Pc For Above Software Tools Along Withinterfacing Hardware Including Hub 156 F3:Mandatory Sparesmax5% Of F1 157 Mandatory Spares 158 Form-6 : Communication System 159 G1 : Mpls 160 Annual Chargesfor 100Mbps Links For Mcc & Dr Center 161 Annual Chargesfor 8Mbps Links For Substation & Remote Vdu 162 Mpls Router 163 G2 : Mandatory Sparesmax5% Of G1 164 Mandatory Spares 165 Form-7 : Power Supply 166 H1 : Main Equipments - Control Centre 167 Ups With Suitable Rating Running In Parallel Redundant Mode* ( Including Vrla Type Battery Banks For Above Ups For Minimum 30 Min. Backup Duration ) 168 H2 : Main Equipments - Dr Centre 169 Ups With Suitable Rating Running In Parallel Redundant Mode* ( Including Vrla Type Battery Banks For Above Ups For Minimum 30 Min. Backup Duration ) 170 H3:For Rtu / Data Concentrator / Communication Eqpts. 171 Dc Power Supply ( Dcps ) System Based On Smps ( Including Battery Bank For Above Dcps ( Vrla Type ) For Minimum 4 Hrs Backup ) 172 H4 : For Rtu / Data Concentrator / Communication Eqpts. 173 Ups ( 2 Kva ) 174 H5 : Mandatory Spares For Ups 175 5% Of Above H1 To H4 176 Form-8 : Scada Enablers 177 J1 : Control / Power Cable For Rtusfrom Outdoorswitchgear, If Any At S / S And Numericalrelays 178 Control Cable Armoured ( 1 Sq Mm For Control And Monitoring Element Wiring ) ( As Required ) With Miscellaneous Consumables Items For E.G. Connectors, Thimbles Etc ( 30 Mtr Per Dss ) 179 Control Cable Armoured ( 2.5 Sq Mm For Ct & Pt Wiring ) ( As Required ) With Miscellaneous Consumables Items For E.G. Connectors, Thimbles Etc ( 30 Mtr Per Dss ) 180 Serial Communication Cable ( 2 Pair Laid In Armoured Steel Conduit ) To Integrate Existing Relay Or Meter Or Fpi ( 20 Mtr Per Rmu ) . 181 Ethernet Cat6 Cable In Steel Conduitto Integrate Existing Relay, Meter Or Wan Router Connectivity ( 20 Mtr Per Rmu ) With Miscellaneous Consumables Items Like Rj 45 Connectors & Patch Code 182 Numerical Relay / Bcpu- Iec-61850 Compiant 183 Iec 61850 Compliant Relays For66kv Panelsas Per Technical Specifications 184 J2 : Mandatory Sparesmax5% Of J1 185 Mandatory Spares 186 Form-9 : Training For Employees 187 Operator For Scada / Dms Control Centre 188 Instructor For Dts 189 Computer Hardware & System Software 190 Application Software ( Scada / Dms ) 191 Rtu & Frtu 192 Database & Display Development 193 Auxiliary Power Supply 194 Communication System Including Nms 195 Form -10:Fms 196 Fms Charges For Scada / Dms System ( Maintaining Overall System Availability As Per Ts ) ( Per Year ) 197 Fms / Year 198 Fms For 2 Years 199 Fms For 5 Years ( Add. 3 Years ) 200 Fms Charges For Scada / Dms System ( Maintaining Availability Individual Hardware & Non –Critical Functions As Per Ts ) 201 Fms / Year 202 Fms For 2 Years 203 Fms For 5 Years ( Add. 3 Years )
Contact Information
Contact Person
CE/SCP
Address
Office of CE/SCP DHBVNL Hetri House Sector 16 Gurugram
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 75604483
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.