Tender For Supply Of Medical Equipments & Instruments Under Dmft Fund To Government Dental College & Research Institute, Vims, Ballari 1 DE001 X-Ray Film Viewer 1.Ultra Thin X-Ray Film illuminator using LED Lamps. 2.The Thickness should be 25mm – 30mm. 3.It should be suitable for viewing 14” x 17” films. 4.It should have LED lamps having life-span of more than 100,000 hours. 5.It should have easy insertion & removal of the films. 6. It should have homogeneous illumination & having luminance of more than 1200 cd/m2. 7.It should have separate On-Off function & separate rotary continuous adjustable brightness control for panel. 8. It should have auto on/off function with insertion and removal of films. 9. It should have fully electronic continuous brightness control, with adjustment range of approximately 90%. 10.It should be directly connectable to power supply without any external adaptor. 11.It should have Flicker free high frequency light for reduction of eye strain. 12.It should have external fuses for protection against power surge. 13.Manufacturer/Item should be ISO/FDA certified. Each 05 2 DE002 Operating Table (Trauma/Multi function, Electrically operated) • It should be Five sectional, SS top 304 grade O.T.Table. • It should be electrically driven with remote operated. • It should have Leg section removable and adjustable. • It should have Base, main frame, fitting sandaccessoriesmade of Stainles steel • ItshouldbeRustProofdesign. • ItshouldhaveQuickandefficientfloorlockingandcontrolled. ➢ MEASUREMENTS: • TheOverallLengthofTabletopshouldbe:1950mm. • OverallwidthofTabletopshouldbe:550 mm. • Min.Height:750-770mm • Max.Height:1000-1020mm • Trendelenberg:200 • ReverseTrendelenberg:180 • LateralTilt:180 • Chair:750-800 • Flex/Reflex:250/2100. • LongitudinalShiftofTabletop:300mm ➢ ACCESSORIES • Antistaticrubbermattress :1 set • S.S.TopArmboard :1pair • AnestheticScreen :1pair • ShoulderSupportPadded :1pair • LateralSupportPadded :1pair • Geopaltypelithotomycrutches:1pair ➢ CERTIFICATIONS a. ItshouldhaveCECertifiedorFDA Certified. b. CompanyshouldbeISOcertified.AvalidISOcertificatetobesubmitted. ➢ WARRANTYANDMAINTENANCE Three(3)years Warranty Each 1 no. (major OT) 3 DE003 Electrosurgical: Unit (Monopolar-bipolar) • The system should provide both monopolar and bipolar current option and clear digital display of power selected with power adjustment knobs • The system should provide high patient safety from burns caused on the patient’s skin due to leakage in the electric current. The power should not be delivered when there is a leak in the circuit • The system should have start-up functional if any error the system should not deliver power. • The system should have the following modes 1. Monopolar pure cutting 2. Monopolar blend cutting 3. Monopolar super blend cutting Each 2 nos. (1 Major OT + 1 minor 4. Endo mode- time controlled cutting mode 5. Monopolar contact cogulation 6. Monopolar forced prep coagulation 7. Monopolar spray cogulation 8. Bi polar cogulation • The system should incorporate a connector which can allows connection of monopolar hand switches and bipolar electrode socket equipped with any of the international accessories • The system should have the option of operating monopolar cutting and coagulation by using both hand and foot switch • The system should have the option of using bipolar coagulation with automatic function • The system should have the option of connecting argon beamer system at a later stage. • The system should be supplied with standard accessories for both monopolar and bipolar • System should be Class of protection I Clasified acc. To mddii b • defibrillator proof protected. • Should have Nominal frequency at least 450 khz and Pulse frequency at least 30 khz with Hf output power. • CE marking conforms to 93/42/EEC • Power Max.400W at 300 Ohm and min. 100W at 100 Ohm Should offer the following accessories • Footswitch double pedal • Patient plate reusable o Bipolar forceps straight blunt nonstick type-3 no o Bipolar cable -3 no • Monopolar diathermy accessories for open surgery o Electrode handle with 5m cable-3 no o Electrode set of 5 consisting of o 4mm lancet electrode straight o 4mm knife electrode o 4mm needle electrode o 4mm ball electrode o 2mm ball electrode 4 DE004 Vertical High Pressure High Vacuum (HPHV) Steam Sterilizer: Application: Autoclave is used for steam sterilization of a wide range of instruments, rubber articles, metal components and fabric commonly sterilized in the Hospital. Sterilization should be carried out at 1210C or 1340C depending on the loadconfiguration for settable sterilization times. Each 01 Design Standard: The pressure vessel is designed as per ASME SEC VIII and welding joints are partially radio graphed for high security. Chamber Size:Sizeatleast - 600 Ø x 1200 mm long. 340 liters. Chamber: The chamber is Horizontal Cylindrical in shape and is fabricated from stainless steel S.S. 304 with full argon welding. The S.S. chamber has a high resistance to steam corrosion. The chamber is easily cleanable and is designed to ensure full draining of condensates. A removable screen plug is provided in the drain lines to prevent clogging of the drainpipes and fittings. The chamber is provided with a safety valve. Jacket: The chamber is re-enforced with stainless steel S.S.304 jacket. The jacket besides re-enforcing the chamber also ensures temperature uniformity in the sterilization space. The jacket is provided with a safety valve. Insulation: The jacket is insulated with 25mm thick non-fiber shredding resin bonded glass wool, which is held in place with an anodized Hammer toned aluminum outer cover. Door: Single / Double Door. Autoclave should have a manual, hinged door. The door is fabricated from SS 304. The high temperature resistant silicone-sealing gasket is pneumatically actuated for effective door sealing. In Built Steam Generator: Should have atleast - 18 KW The steam generator is fabricated from stainless steel SS 304. Water filling should be automatic. The steam generator should be insulated with resin embedded rubber sheet with aluminum cover to prevent heat loss. A safety valve should be provided. Automatic water level control along with low water level protection is provided to safeguard the SS 304 heaters. Vacuum System: A high capacity water ring Vacuum Pump should be provided for creating vacuum in the chamber for mechanical air removal prior to sterilization and subsequently for post sterilization vacuum drying. PLC Control System: The steam sterilizer should be operated through a PLC. The PLC is equipped with a non-erasable memory and battery back up for in-interrupted operation. Recorder: A compact Thermal Recorder is provided for batch record of temperature/ pressure & time. Colored HMI: A 5.7” color touch screen should be provided for greater graphic process visualization. All message, temperature and pressures are easily displayed on the LCD. The HMI should also displays MIMIC process flow diagram, which enables to understand the various process stages. Cycles: Instrument Sterilization @1210C Instrument Sterilization @1340C. Garment Sterilization @ 1210C. Garment Sterilization @ 1340C. Open Liquid Sterilization @ 1210C. Rubber Component Sterilization Alarms: Chamber pressure high alarm. Chamber temperature overshoots alarm. Temperature Sensor fails alarm. Pressure sensor fails alarm. Piping: Piping is of SS 304 with 2% slope for complete drainability. Shelf / Tray: Should have at least two removable perforated stainless steel trays for easy loading and unloading of packs. Valve Package: All valves are sturdy, reliable and long lasting. The valves are suitable for high temperatures and high pressures. The valves are automatically operated through the PLC. Enclosure: Should be provided with powder coated paneling on all sided with service door. The panels can be easily detached for ease of service & maintenance. Shifting Wheels: Should have four, lockable PU wheels for ease of shifting the machine to any convenient location. Safety: Door lock to prevent door opening when the chamber is pressurized. Over pressure safety valve for jacket and chamber. Low water level protection is provided in steam generator. The door cannot be opened when the process is on. The process will not start if the door is not sealed. Door interlock for double door machines. Accessories: Bins 4 No should be supplied & Transfer trolley 01 No 5 DE005 Surgical Loupes : 1.System carrier - Head band system, size of the head band can be personally adjusted Each 01 2. Lens protection device - Protects against tissue debris with AR coating 3. Contact guard - Sterillizable to reliably swing loupes up and down 4. Working distance(mm) - 450- 500mm 5. Magnification – (3.5x) 6. Field of view (mm) - 93mm-100mm 7. Light source - Powerful LED light source with integrated temperature control 8. Control Unit - With 3 step intensity control, charge level indicator and belt clip 9. Adapter for loupes - To attach to the loupe 10. Cable clip -To connect the lamp cable to the carrier 11. Soft case - Shock-proof protection for loupes, light source and accessories 12. Light intensity - Up to 50000 Lux ( at distance of 300 mm) 13. Typical color temperature - Resembles daylight 14. Weight of illumination head - As light as possible 15. Batteries Charger - Medical grade lithium- ion smart battery packs for fast charging 16. Battery charger - 17. Battery run time - Around 4 hours at 100 % light intensity and 6.5 hours at 33% light intensity 18. Battery charge time - 2-3 hours 19. Additional accessories Protective Lens Caps, Sterillizable contact guards, Optics cleaning cloth 6 DE006 Surgical Hand pieces. NSK or Zimmer 1:2 (Increase Gear): Oscillating-01 No+Sagittal-01 No+Coronal/Axial-01 No (03 No Set) Each 04 7 DE007 ECG machine. 12 lead Should be from a reputed manufacturer with universal power supply facility ( 100 to 240 VAC ) with Compulsory FDA or CE approval Simultaneous 12 channel ECG recording with 12 lead simultaneous acquisition Should have visual alarm for open lead. Light weight with built in battery & one touch operation for age and gender shortcut 12 channel ECG machine with 12 leads simultaneous acquisition & accurate interpretation facility. Should have a built in 8 “ LCDcolor screen display for waveform monitoring facility. Built in 210 mm thermal printer & direct print facility with external printers Should have alphanumeric QWERTY key board for entering patient data. Should display heart rate, time, date, leads, filter, calibration, patient details. Sampling frequency per channel should be 10000/sec/channel Internal memory storage of up to 500 ECG records with facility to store more by using flash disk. Should have facility to convert ECG into PDF, XML, DAT format before transferring. Recording mode auto, manual, rhythm, RR Analysis Should have VECG optional Rhythm – single or 3 leads selectable facility 120s real time ECG waveform freezing facility and review facility. Weak signal detection with advanced 24 bit A/D conversion technology Should have option to save data in memory without taking printout. USB port for data transmission and external printer connectivity. Should have CMMR of 115 or more. Built in Battery backup for minimum 200 ECG records print out. Should print report on 210X295mm paper Should be a latest model & support barcode scanner to simplify workflow. Should be supplied with 50 printer papers. 8 DE008 Dermatome (Huby’s knife) Material: Austenitic steel Specifications: Manual dermatome handle by Humby Adjustable from 0.1 to 1.2mm Width of cut: max. 160mm Full length: 31 cm Packaging: Unit presentation: individual, with protective wrapping. Other requirements: Conforms to ISO standard (dermatome, Humby), BLADE Material: Martensitic steel Specifications: Rectangular blade to be attached to a dermatome. Each 01 Packaging: Unit presentation: individual, with protective wrapping The following should appear on the packaging: - designation of the instrument - name and address of supplier (manufacturer) Other requirements: Used with Schink dermatome Conforms to ISO standard. 9 DE009 Fumigator (O.T Fogging Machine) Should have a consistent particle size generation of 5-15 microns or better. Each 01 Should have a maximum through put of 4 meters in a closed room. Should have a vortex type design,non-rotating and non-clogging nozzle assembly. Should have tough and corrosion resistant power head housing. Should have a chemical solution tank of minimum capacity 5 litres. Should have a tough and corrosion resistant tank.The bolts,nut sand washers used inside the tank should be stainless steel/brass. Should have an easy to clean,detachable and non-corrosive chemical solution tank. Should have primary and secondary filtration for the air intake system. Should be compatible with wide range of disinfectants. Timer should be provided Should operate from 200 to 240 Vac,50Hz input supply. It should be CE and ISO Certified 10 DE010 Xerox machine. S. No Specifications Parameters 1 Speed (A4) 23 cpm 2 Functions COPY + PRINT + SCAN (Col) 3 System Memory 512-MB 4 Duplex Std 5 RADF Optional 6 Connectivity USB USB 2.0/ Hi Speed Network Std (10/100 BaseT) 7 Std. Paper Capacity Auto Tray (A5 to A3) 250 sheets Bypass Tray (100 sheetsx1) 8 PDL PCL 9 Print Resolution 2400x600 (with smoothing) 10 Scan Scan to USB Scan to File (SMB/ FTP), Scan to Email 11 Print From USB YES 12 Department Codes Upto 100 codes Each 1 no. 11 DE011 C-mac Videolaryngoscope/ Video Laryngoscope. Laryngoscope required with video illumination to visualize and document the operational area on screen. It should cinsist of following features: Monitor: 1. Screen 8 to 12 inch size for display with touch screen to control features with HDMI output for connecting to a big screen which can display picture simultaneously on both screens. 2. Monitor should have two ports to connect two video laryngoscope blsades at one time and picture can be swapped using touch screen. 3. Monitor should be chargable, to be supplied with charger and should have facility to be used while charging. 4. Monitor resolution should minimum 1920x1200 pixels in 16:9 farmat. 5. Integrated recording of video & still images should be possible on data cardor USB drive with JPEG and MPEG format which can be easily transferred to the computer/ laptop. Documented videos & still images should be easily recalled on the monitor. 6. Monitor should have a facility to connect flexiable scope directly without aaaaaaaaspecial coupler or accessory. 7. Monitor should have Picture-in –Picture & side-by-side mode to view images from 2 different blades or flexiable video scopes. 8. Monitor should be splach proof according to IP 54 and should be shock resistant. 9. Monitor should have lithium –lon rechargeable batteries and run for at least 100 mins. When fully charged. 10. Soft bag from same manufacturer should be supplied to place the monitor and system can also be operated without taking monitor out from the bag. 11. Adult and pediatric angulated Magill forceps from same manufacturer to be provided for foreign body removial and assisting nasal intubation while using blades 12. Same monitor should be compatible with all the bilow mentioned scopes of same manufacturing principal company * Reusable video laryngoscope * Single use video laryngoscope * Reusable Flixible Intubation video endoscope * Single use Flixable Intubation video endoscope * Video intubation endoscope with flexible tip Video Laryngoscope-Reusable 1. Blades and connection cable should be fully immersible in disinfecting solution. 2. Blades should have a button for real time documentation. 3. Blades can be sterilized using sterrad and steris system. Thermal disinfection upto 93 degrees and chemo-thermal disinflection upto 65 degrees should be permissible. 4. Special angulated Adult Blade for difficult intuvation with device for introduction of suction catheter of size 16-18 Fr., angle of view should be 70 degree or more shoule be provided with stylet from same manufacturer. 5.Accessories like protection cap for blades, tray for cleaning and sterilization of blades (at least two blades at a time) from same manufacturer should be Provided. 6. Stand to hang monitor with tray for laryngoscope blades should be provided All the items should be CE and FDA certified from a notified body. 12 DE012 Formalin Chamber Acrylic Sheet Chamber for Instruments: Each 02 1. Size 26” X 8” X 8” 2. Sheet Thickness 6mm (made of clear transparent acrylic sheet) 3. With 3 white perforated tray. 4. With handle on the top 13 cm X 4.3 cm of 8 mm Thickness 5. Door on the side for closing 6. Lock on the front near the door 7. Supporting stick on the side of lock door to open. 13 DE013 UV Chamber Large UV chamber Each 08 Minimum 12 trays. 15W UV light or above. 220V AC. 14 DE014 Direct Laryngoscopes. Macintosh Miller Macintosh, all blades (1-4 nos.) LED light source with rechargeable batteries. Miller, all blades (1-4). LED light source with rechargeable batteries. Each 2 set each. 15 DE015 Voltage stabilizers CVT stabilizers for Major OT and minor OT. 5 kVa. 110-260V range, Sinewave, controlled 220 V output. Each 2 nos 16 DE016 Jet Venturi Anesthesia (For Anesthesia work Station). 1. Multipurpose Portable venturi based jet ventilator. for Trans tracheal Ventilation and other airway interventions. Each 01 2. Should be easily clamped to bedside and anaesthesia gas machine. 3. Should provide Bag-in-bottle attachment and Jet Humidifier 4. Controlled Time Cycled 5. Power source with oxygen/air at 50 P.S.I 6. Inspiratory time 0.5 to 2.5 sec and expiratory time of 0.5 to 5 sec. 7. Flow rate at 10-90 Lt/min 8. Maximum positive pressure of 50 cm of water. 9. Should be provided with accessories like needle, adapter to connect to bronchoscope, adapter to connect end tidal Co2 sampling line (Optional) 10. Monitoring of peak inspiratory, peak end expiratory airway pressures and automatic shutdown feature if either of these pressures are exceeded (Optional). 11. Should have safety certificate from a competent authority 17 DE017 IV fluid & blood warmer blood and fluids warmer, between 37 - 42°C, delivering warm fluids to the patient at flow rates up to 5000 ml/hr Portable pole-stand mount. Rechargeable battery backup for 4 hrs or more. EACH 2 NOS. (1 MAJOR OT+ 1 icu) 18 DE018 Patient Body warmer Blankets Easy hose hot plate, body warmer blanket for adult and paediatrics. Each 02 19 DE019 Core Saw and Console 1.The drill machine should be battery/ electric operated Each 01 2.The drill should be capable of autoclaving and should be quoted with the autoclavable box. 3.Should have high torque for drilling in small bones. Rpm min 900, with mini coupling 3000approx. 4.It should be Light, handy and versatile Variable speed with oscillating drilling. 5.Durable and Easy to use, highly functional attachments or power adapter Microprocessor controlled un 6.Various attachments should be quick coupling. 7.The catch of the drill bits should be friction lock. 8.There should be attachment for the saw blade fixing. 9.Should have electric console attachment. 10.There should be oscillating drill mode for soft tissue protection 11.The compact control unit features a sophisticated desigh include a large, high visibility backlight LCD panel and Intutive control buttons to contribute a safer and user friendly working environment 12.The Programmable parameters are gear ratio, speed Rotation direction, torque limit, coolant solution volume and illumination intensity. This is extremely useful when using two or more implant brands 13.Advanced Irrigation Pump 14.The Pump should allow easy set – up of irrigation tubes and is should be extremely quiet during operation 15.The instruments must be ISO certified and CE or FDA certified. Core saw for Craniomaxillofacial surgery. REMB handpieces: Sagittal handpiece Oscillating handpiece Reciprocating handpiece Blades for each saw -10 Nos. Digital console with integrated irrigation pump and digitally controlled speed and torque. Console compatible (REMB handpieces) 20 DE020 Distraction Osteogenesis Kit 1. Intra Oral Distractor Maxillarty Rt/Lt.SS Each 01 2. Intra Oral Distractor Mandible Rt./Lt. SS 3.Intra Oral Distractor Alveolar Rt./Lt. SS 4. Activator for Intra Oral DistractorsSS Extra Oral Transport Distractor 5. Mandibular – SS 6. Activator for Transport Distractor SS 7. Extra Oral Hemi Transport Distractor SS 8. Extra Oral Distractor Uni Directional SS 9. SD-EA-003 Activators For Unit-Planar EOD’sSS 10.Extra Oral Distractor Bi Directional SS 11.Activators for Bi-Planar EOD’s-SS ,MADRED-Mid Face Distractor SetDistraction Pin Positioning Rod – Stabiliser – 1 No Distraction Pins – titanium – 2 Nos Screw Driver –1No Allen Key –1 No Distraction Activating Key – 1 No Carrying Case – 1 No 21 DE021 Digital OT 1. OT Each 01 In addition the technological medical capabilities are extending tremendously too, such as possible natural or artificial implants will become more andmore common. Sterility in an operating theatre is an absolute imperative for ensuring that patients are protected from life-threatening infections. the filter creates homogeneous laminar flow with very little turbulence. Any bacteria, viruses or dust particles are extracted directly before the air enters the area. This means that the operating area is completely isolated within the surrounding room, effectively preventing any contamination by bacteria or virus-laden air. Based on the 20 years of experience consequently is contributing to the improvement of the aforementioned hospital areas and of reducing the risk of infection by designing and installing down and cross-flow-systems for the hazardous areas where patients are treated. The Laminar Flow Workstations operate by drawing ambient air, in the positive pressure into the unit. The room air will suck from all four sided risers and first passes through a Pre-filter which traps the larger dust and dirt particles. The blower then directs this pre-filtered air, now under positive pressure, through the 99.997% efficient HEPA filter engulfing the entire work area with sterile, unidirectional ultra-clean air. This air travels at a velocity calculated to prevent the intrusion of unfiltered room air into the operation table. It also washes away particles that may be generated by manipulations within the operation table. M Operation Laminar flow bench provides a HEPA filtered airflow across the table, and a particulate-free work table 1.To dilute the bacteria generated by the operating team and patient in the theatre. 2.To prevent less clean air from neighbouring rooms entering the operation theatre 3.To create an air flow pattern that carries contaminated air away from the operating table. 4.Optimize working conditions : To provide a comfortable environment for the operating team and patient, with controlled temperature, humidity and ventilation. 4.Integrated technologies augment surgeons’ skills and help the entire surgical team work more safely and efficiently A.Allow flexibility B.Minimizes maintenance C.Ensure functional separation of spaces. D.Regulates flow of traffic E.To provide full control for the Surgeon or his assistant of the OT equipment, and environment. F.Capable of maintaining a particulate free work table when operated in an uncontrolled environment. G.Achieved by total removal of air borne particulates droplets & dust borne micro-organisms by unidirectional clean airsystem. H.Rely on air flow in which the entire body of air within a confined area essentially moves non turbulently along parallel flowlines. I.The velocity through the cross section of the work place is conventionally maintained at 90 ± 20 FPM. J.Complete cabinet made from 1.2 mm thick MS Powder Coated Housing K.HEPA filters EU14 L.Provision to accommodate integrated light tubes with a special light reflection design. M.Provision to accummlate OT light at the centre point of the cabinet. The OT light shall be fixed to the RCC slab through the cabinet. Note : The air from the AHU outlet is treated with HEPA Filters (99.997% efficiency) placed in the laminar flow hoods on th ceilings and is directed toward the OT table at an optimum speed and is guided towards the wall exhaust which is connected to the main exhaust and is treated there. The ceiling hood should be in anodised extruded cell side constructed with an aluminium top plate. An inlet collar with a suitable height is provided. The filters are installed from the clean room side and positioned with 4 support strips. The filters should automatically sealed with permanent knife edge in the hood. The return air should be picked up taken out from the exhaust grille located near the floor level (apox 6 inches above the floor level) I. OPERATION THEATRE LAMINAR AIR FLOW Ceiling Suspended OT Laminar Air Flow Size : 8’ x 6’ x 1’ Material of Construction : Stainless Steel 304 Supply and Fixing of Laminar Air Flow (LAF) arrangement with a cabinet (housing) of size 2440 mm x 1860 x 350mm depth made out of prime quality Stainless Steel 304. The entire working zone will be lined with joint less Stainless Steel 304 with coving on all vertical corners for easy cleaning. The cabinet will be hung from the suspension rod. Access for servicing the replacing HEPA Filters will be provided from the bottom side of the unit. HEPA Filters separatorless minipleat HEPA in alumium extruded frames with wire mesh protection and made of Ultra Fine Glass fiber media having a retention capacity of 0.3 micron at 99.997% efficiency with initial pressure drop of 12 mm WC The filter media (HEPA Filters) made out of Micro glass fibers with an efficiency of 99.997% down 0.3 microns (6nos.) in each LAF cabinet. MCCPL/OT/Central/325/17-18 July 30, 2018 Controls Suitable control panel consisting operating switches, indicators, power-surge protection etc will be provided separately, which can be mounted as per user’s convenience. The cabinet shall be provided with DOP test port for checking HEPA filters integrity & with built in dampers for controlling air flow across HEPA filters The cabinet shall have provision to accummlate OT light at the centre point of the cabinet. The OT light shall be fixed to the RCC slab through the cabinet. TECHNICAL FEATURES AIR FLOW: Ceiling Suspended Laminar Airflow provides ultra clean sterile CLASS 100 clean air and is designed as per CLASS 5 OF ISO 14644-1 standards a.Application : To provide Class 100 Clean air over an OT table b.Airflow : Vertical downward c.Air Velocity : 90 feet per minute + /- 20% d.HEPA Filter Area : 100% face area except the space formounting OT light e.Standard : Class 5 of ISO of 14644-1 / CLASS 100 OF US FED STD. 209E , NABH f.Cleanliness : Class 100 (ISO 5 for particle sizes 0.5 m <3530 Particles M> of air at both at Rest & Operation Condition as per ISO 14644-1 g.HEPA Filter Size : 915 x 610 x 100 - 6 nos 610 x 610 x 100 - 2 nos Total 8 Nos h.Type : Box type, i.Media : Ultra clean glass fibre paper-imported j.Casing : Aluminium Powder coated k.Retention : 0.3 Micron l.Efficiency : 99.997% m.Pressure drop : 25 mm of WC n.Airflow : 4000 cfm o.Filter Area : 48 sq.ft. p.Construction : Stainless Steel 304 HEPA FILTER: All HEPA Filters will be protected by SS 304 Grille. CLEANLINESS LEVEL: Class 100 POWER SUPPLY : 415 V AC RETURN AIR RISERS The room air will suck from all four sided risers and first passes through a 10 micron Pre-filter which traps the larger dust and dirt particles. The blower then directs this pre-filtered air, now under positive pressure, through the 99.99% efficient HEPA filter engulfing the entire work area with sterile, unidirectional ultra-clean air. This air travels at a velocity calculated to prevent the intrusion of unfiltered room air into the operation table. The riser will be protected by SS 304 grille. Size : 600 x 300 x 3050 mm Qty : 4 Nos. DUCTING 24 kg GI angle frame Ducting complete with support, GI nut-bolts, gaskets, G.I. Flanges, sealant, etc. INSULATION Duct Insulation for the supply 13 mm rubber and return duct to be made 9 mm Nitrile rubber. Duct insulation with XLC-EPE insulation laminated with Aluminium Foil foil of reputed make. CEILING PANEL CEILING PANEL: Supply erection and testing ceiling panels with Puf material made of Stainless Steel 304, 0.8 mm sheet in the front side and backside Precoated Galvanised Iron and PUF placed in a particle tight frame with caulking silicone sealing. The panels thickness shall be 50 mm filled with puf having density more than 45Kg/m3 as per the specification complete spring isolator anchor fastner, zinc coated M - 8 threaded hook rods, turn buckle, hardware etc. including cutout for light fixtuers, Laminar flow Tent cutout etc complete as per the ceiling layout. WALL PANEL PU PAINING –MRF BRAND. COVINGS Extruded Aluminium coving type R 90 covings for the entire wall to wall, wall to ceiling and Coloumn Corners coving made of AI buffed profiles with back runner and Corners. 3 Way corners Coving MCCPL/OT/Central/325/17-18, July 30, 2018 ANTI-STATIC VINYL FLOORING Providing, Fixing, Supply and Installation of seamless static conductive Vinylflooring system , 2 mm thick ,with perfectly curved flash covings as per the colour and pattern approved by hospital. Imported german make With self levelling compound. SS DOUBLE SIDE DOORS • 50 mm thick doors • Material of Construction SS 304, 1 mm thickness on both sides with PUF as infill, • 1 mm thick sheet • Frames totally flush with the wall panels, • Hardware like push plates, handles, • Dorma TS 71 Hold open type door closure, double glazed view glass of std size, SS ball bearing butt hinges • View panel 750 x 450 with glass • Single leaf door of size • Drop Seal MCCPL/OT/Central/325/17-18 PENDANTS Pendant - Single Arm Pendant, Horizontal Movement only, comprising of:- a.1 x Articulated Arm - 1000 mm b.1 x Basic Console - 800 mm c.3 x Single Shelf 470 mm x 360 mm x 30 mm d.2 x IV Poles set (tube +4 bottle holding tube) e.8 x Mains Socket (6/16A single phase) f.6 x Medical Gas Terminal & Hose Assembly g.Medical Rail - One Set h.Provision to mount surgical accessories such as Electro – cautery, surgical trays etc. i.Provision to mount monitor unit j.Other utility accessories k.Pendant carrying capacity of 100 kg equipment load pendant rotate at 330°. l.Provision of Music controll and Provision of data cable Socket CONTROL PANEL Providing, Fixing, Supply, Installation, testing and Commissioning of Membrane type Surgeon Control Panel( 6 services ), mounted flush in the theatre wall alongwith a.Distribution Board comprising of the following : b.1 No Day time Clock (Digital) c.1No Lapse Time Clock (Digital) d.1No Hands free telephone e.1No Medical Gas Alarm f.1 Set indicator for temperature &humdity pressure display g.1 set Lighting control, Peripheral and PlainairOn/Off with dimming Control Switches for Light Controls h.Gas Controls i.Medical gas Control MCCPL/OT/Central/325/17-18, July 30, 2018 X-RAY VIEWER – MRI Twin plate X-ray viewing LED Screen, designed to provide a high level of control luinance without flicker. MRI WRITING LIST BOARD Writing Board of size 840 x 640 mm comprises of a flush mounted. 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibreboard sheet for additional rigidity SURGICAL SCRUB SINK Supply and Fixing of compact fully stainless steel scrub sink which offers twoscrub stations. Scrub sink is fabricated from type 304, 1.2 mm stainless steel. The scrub is polished to a satin finish. The scrub sare ink is fitted out with 2 Nos taps with flow attachements. The unit is designed to be installed on the wall using brackets. The scrub can be operated using the foot switch.(usually kept hidden inside the base covering plate). PERIPHERAL LIGHTS Supply and Installation of LED Lights. a) 2’ x 2’ LED LiGHTS-12 SPLIT AC- 2.5 TON -2NOS With installation SS storage cabinet: 3x6 feet- 4 Nos 22 DE022 HD Microscope – Tablet integrated with image system Upright bright field, digital benchtop microscope with inbuilt integrated tablet display (no eyepiece/ optional binocular head can be used), application and research grade optics Each 02 a).Patented detachable digital head with Internal magnification 10X b).TrueView technology for capture of 100% circular field of view through the tablet camera; Captured field of view: diameter 5.5 mm with 4x objective, 2.2 mm with 10x objective, 0.55 mm with 40x objective and 0.22 mm with 100x objective c).Quintuple inward facing nosepiece d).Four high contrast premium infinity corrected plan achromat objective lenses – 4x, 10x, 40x, 100x oil immersion e).1.25 NA condenser; 3 watt LED illumination with intensity control f).Rackless X-Y stage g).Double plate stage size 190-140 mm h).Coaxial coarse and fine focus knobs i).iOS display with Maximum camera resolution of 3024 x 4032 pixels and 11” display with 2388x1668 pixels resolution; 64 GB ROM j).Ultra HD video capture at 3840 x 2160 pixels k).Pre-installed application with following features: l).Data management m).Image capturing n).Video recording o).Exposure, brightness, saturation, temperature and contrast control p).Micrometry – linear and circular measurements in microns r).Annotations and text addition s).Free hand marking and pointer for demonstration t).Wireless HDMI dongle for lag-free real time casting to projector or LCD screen (accessory) 23 DE023 Semi Automatic Microtome. Semi automatic rotary microtome with stepper motor driven specimen feed. Each 1 Vertical and horizontal cross roller bearings mechanism to ensure accurate reproducibility of section thickness. Section thickness selection from 0.5 to 100 mm. Setting value 0.5-5 mm (In 0.5 mm increment) 5-20 mm (In 1 mm increment) 20-65 mm (In 5 mm increment) 60-100 mm (In 10 mm increment) Trimming step settings from 1-600 mm with step trim function. Setting value 1-10 mm (In 1 mm increment) 10-20 mm (In 2 mm increment) 20-50 mm (In 5 mm increment) 50-100 mm (In 10 mm increment) 100-600 mm (In 50 mm increment) Programmable retraction from 0-100 mm. Retraction can be deactivated when not required. Motorized two speed coarse feed of 300 and 800 mm/sec. Two modes of sectioning by manual rotary action and by rocking action called ergo mode to minimize the risk of developing repetitive motion disorders (RMD). Programmable horizontal stop function to move specimen to a defined feed position. Separate control unit with display for section thickness, number of sections, thickness totalisation, section counter and trimming thickness. Horizontal feed of 24±1 mm and vertical stroke length of 70mm±1. Visual and acoustic remaining feed indication. Specimen orientation with zero position horizontal / vertical rotation: ± 8°/ ± 8° Knife holder base with lateral displacement. DIMENSIONS AND WEIGHT Width (including handwheel and coarse feed wheel) Depth (including the section waste tray), Height (without top tray) W x D x H: 477 mm x 620 mm x 295 mm Maximum specimen size (H x W x D): Large standard clamp: 55 x 50 x 30 mm Super Cassette clamp: 68 x 48 x 15 mm Unique force balance system eliminates the risk of injury unbalanced object head Specimen retraction: 5 - 100 μm in 5 μmincrements;can be turned off Slow forward and backward speed Fast forward speed Fast backward speed (fast homing) 300 μm/s/ 800 μm/s/1800 μm/s Waste tray- Antistatic tray Hand wheel lock/break- Two mechanical locks Relative humidity during storage 10% to max 85% non condensing Relative humidity during operation 20% to max 80% non condensing Temperature range during storage +5ºC to +50ºC Operating temperature range +18ºC to 35ºC Maximum heat emission 70 J/S Suitable stabilizer /ups to be provided. 24 DE024 Tissue Flotation Bath. A flattening bath for paraffin sections with digital display and set value memory to stretch and flatten sectioned tissue specimens for all areas of biomedical research and routine histopathology diagnostics. Each 01 The water bath should have a high heating capacity and precise temperature control. Continuous temperature control up to 70 °C. Jet black surface to identify sections Broad rim to store microscope slides Easy and rapid cleaning This should be a rectangular water bath designed with a surface ensuring high thermal conductivity rates and outstanding resistance to mechanical damage owing to its special plastic coating. Programmed as well as current temperatures are shown on a LED display while the selected temperature set value is memorized via a built-in battery backup system. To increase safety and reliability the water bath features an overheating protection system along with a stand-by mode. The overall design is modern and complementary to the Histology Product Line so that the user can comfortably operate it in most routine applications. The water bath can be used in conjunction with the hot plate for drying and stretching glass mounted histology sections. The broad, oversized rim of the water bath allows easy and convenient storage of microscope slides, and in addition the rounded inner corners of the instrument allow it to be cleaned efficiently.
|