Rate Contract For Supply Of Consumables/Non-Consumables For The Department Of Neurosurgery Supply Of Rate Contract For Supply Of Consumables/Non-Consumables For The Department Of Neurosurgery , "Tender Conditions: (Please Read Carefully!) 1) Samples To Be Submitted For All Consumable Items, Otherwise Your Bid Will Not Be Considered. 2) Sample / Catlogue Of Instrumentswith Details Of The Make And Design Should Be Made Available Failing Which The Bid Will Not Be Considered. 2) All Instruments Should Have Company Name, Catalogue Number, Manufacturing Lot Number Embossed On Each And Every Instrument Otherwise It Will Be Rejected 4) Firms Participating In The Tender Must Demonstrate Samples Of The Items If They Are Specifically Asked To Do So. A Certificate Should Be Taken From The Department, Signed By A Neurosurgery Consultant That Samples Were Given And/Or A Demonstration Was Done. 5) The Name And Address Of The Manufacturer Must Be Printed On The Packaging Of The Disposable Items Failing Which The Tender Is Liable To Be Rejected. 6) The Disposable Items Must Have A Shelf Life Of At Least 2 Years At The Time Of Supply Unless The Original Manufacturer Writes, In The Product Insert, That The Expiry Date Is Less Than Two Years From Date Of Manufacture, In Which Case, The Time Till Expiry Should Be 75% Or More Of The Time Described. 7) Staggered Supply Should Be Arranged, Every Two Months, For Items That Occupy Storage Space, On Our Request. 8) All Instrumentation (Implants) Or Staplers Should Be Mri Compatible. 9) In Case Of Non-Consumable With Compatible Proprietary Consumable, L1 Will Be Calculated Based On Combined Value Of Equipment (Total Required) With Consumable (Total Projected Quantity). 10) Please Read Specification Carefully Since Many Details, Including Numbers Have Been Changed. Please Do Not Cut And Paste Previous Quotes!! "All Intruments Must Be Made Of Stainless Steel Or High Quality Appropiate Alloy Materials Unless Specified Otherwise 11) Minorvariation In The Diamension Of The Insturments Will Be Acceptable (After Checking The Sample Provided) 12) For All Consumable / Non Consumable Items Indian Standards Certificate (Cdsco/Sla) Is Mandatory Wherever Indian Standards (Cdsco/Sla) Are Not Available Iso/Usfda/Ce Certificate May Be Produced. , Aneurysm Clip: Yasargil Type, Titanium Max. Opening 7Mm Force 180 Grams, Blade Length 9Mm ,Straight, Permanent , Aneurysm Clip: Yasargil Type, Titanium Max. Opening 7Mm Force 180 Grams, Blade Length 9Mm ,Curved, Permanent , Aneurysm Clip: Yasargil Type, Titanium Max. Opening 7.8Mm Force 180 Grams, Blade Length 11Mm,Straight Permanent , Aneurysm Clip: Yasargil Type, Titanium Max. Opening 7.8Mm Force 180 Grams, Blade Length 11Mm,Curved Permanent , Aneurysm Clip: Yasargil Type, Titanium Max. Opening 5.7Mm Force 200 Grams, Blade Length 7Mm, Straight Permanent , Aneurysm Clip: Yasargil Type, Titanium Max. Opening 5.7Mm Force 200 Grams, Blade Length 7Mm,Curved Permanent , Aneurysm Clip: Yasargil Type, Titanium Max. Opening 3.3Mm Force 110 Grams, Blade Length 3Mm, Straight , Permanent , Aneurysm Clip: Yasargil Type, Titanium Max. Opening 4Mm Force 110 Grams, Blade Length 5Mm Straight, Permanent , Aneurysm Clip: Yasargil Type, Titanium Max. Opening 9.2Mm Force 280 Grams, Blade Length 15Mm,Straight Permanent , Aneurysm Clip: Yasargil Type, Titanium Max. Opening 9.2Mm Force 280 Grams, Blade Length 15Mm,Curved Permanent , Aneurysm Clip: Yasargil Type, Titanium (Steel Component If Titanium Is Not Available With Any Manufacturer) Sundt Graft Type Vessel Wrapping Clip 7 Mm. This Has A Dacron Type Fabric Built Into The Clip To Cover A Vessel Tear. , Aneurysm Clip: Yasargil Type, Titanium, Fenestrated 3.5Mm Permanent Clip - Straight Blade Length 3Mm Mm , Aneurysm Clip: Yasargil Type, Titanium, Fenestrated 3.5Mm Permanent Clips Straight, Blade5 Mm, , Aneurysm Clip: Yasargil Type, Titanium, Fenestrated 3.5Mm Permanent Clips Straight Blade 9 Mm, , Aneurysm Clip:Yasargil Type, Titanium, Fenestrated 3.5Mm Permanent Clips Right Angle 5 Mm , Aneurysm Clip:Yasargil Type, Titanium, Fenestrated 3.5Mm Permanent Clips, Right Angle Blade 7Mm , Aneurysm Clip: Yasargil Type, Titanium, Deeply Curved Tip 7Mm Blade , Aneurysm Clip: Yasargil Type, Titanium,Bayonetted 2.5Mm Step And 5Mm Blade Length , Aneurysm Clip: Yasargil Type, Titanium,Permanent Clips Right Angle 9 Mm Right To Left , Aneurysm Clip: Yasargil Type, Titanium, Permanent Clips Right Angle 9 Mm Right To Right , Aneurysm Clip Yasargil Type, Titanium, 3 Mm Size For Use In Arteriovenous Aneurysm Surgery (Permanent, Mini Clips) , Aneurysm Clip Yasargil Type, Titanium, Permanent Clips Side Angled 7Mm Right To Left , Aneurysm Clip Yasargil Type, Titanium, Permanent Clips Side Angled 7Mm Left To Right , Aneurysm Clip Yasargil Type Temporary Straight 3-5Mm , Aneurysm Clip Yasargil Type Temporary Straight 5-7Mm , Aneurysm Clip Yasargil Type Temporary Curved 3-5Mm , Aneurysm Clip Yasargil Type Temporary Curved 5-7Mm , Ultrashort Fenestrated (Fenestration 3Mm) "Nub Clip". (Yasargil Type , Titanium) , Ultrashort Fenestrated (Fenestration 5Mm) "Nub Clip". (Yasargil Type , Titanium) , Reinforcing Booster Clip, Yasargil , Sugita Type Aneurysm Clip (Titanium Or Permanent) (Low Profile Spring, Sugita Bridge Wire System, And Channel In Blade) Quote A Uniform Rate For A Single Non-Fenestrated Clip. We Will Inform The Clip Size And Shape At The Time Of Purchase Oder , Sugita Type Aneurysm Clip (Titanium Or Permanent) (Low Profile Spring, Sugita Bridge Wire System, And Channel In Blade) Quote A Uniform Rate For A Single Fenestrated Clip. We Will Inform The Clip Size And Shape At The Time Of Purchase Oder , Sugita Clips With Tapered Design With Atraumatic Groove With Laser Etched Lot Number For Identification. Clip Should Be Made Of Non-Ferromagnetic Titanium Alloyal Verified By Astm F136 / Iso 5832-3 For Compatiblity With 3 Tesla Mri. Quote For A Uniform Rate For A Single Non-Fenestrated Clip. We Will Inform Clips Size And Shape At The Time Of Purchase Order. , Sugita Clips With Tapered Design With Atraumatic Groove With Laser Etched Lot Number For Identification.Clip Should Be Made Of Non-Ferromagnetic Titanium Alloyal Verified By Astm F136 / Iso 5832-3 For Compatiblity With 3 Tesla Mri Quote For A Uniform Rate For A Single Fenestrated Clip. We Will Inform Clips Size And Shape At The Time Of Purchase Order. , Perneczky Type Aneurysm Clip. Quote A Uniform Rate For A Single Non Fenestrated Clip. We Will Inform The Clip Size And Shape At The Time Of Purchase Oder , Perneczky Type Aneurysm Clip. Quote A Uniform Rate For A Single Fenestrated Clip. We Will Inform The Clip Size And Shape At The Time Of Purchase Oder , Aneurysm Clip - T Type ,Titanium,Permanent 9Mm Blade Straight 90 Degree , Aneurysm Clip - T Type ,Titanium,Permanent 13Mm Blade Upcurved 60 Degree , Aneurysm Clip - T Type ,Titanium,Permanent 13Mm Blade Downcurved 60 Degree , Aneurysm Clip - T Type ,Titanium,Permanent 9Mm Blade Upcurved 90 Degree , Aneurysm Clip - T Type ,Titanium,Permanent 9Mm Blade Downcurved 90 Degree , Yasargil Standard Bayonetted Aneurysm Clip Applier Titanium Double Hinged Rotating Tip ,Length Around 20 Cm , Yasargil Standard Bayonetted Aneurysm Clip Applier Titanium Length Around 20 Cm , Transparent Cannula Site Dressing Transparent Polyurathane, Impervious To Bacteria, But Permeable To Water Vapor Maintaining Transparency. Self Adhesive (10-15Cm) With A Chlorhidine Gluconate Layer 3-5 Cm) And Iv Line Securing Adhesive Stripand Label. , Odourless Hydrocolloid Dressing With Water Resissnt Film Border And An Outer Barrier Film 15 Cm X 15 Cm , Abosorbant Clear Acrylic Dressing Which Should Be Three Layered With A Top Layer Of Breathable (Letting Oxygen And Vapour) Film , Middle Layer Of Acrylic Polymer And A Perforated Bottom Layer And Adhesive. Size 15 Cm X 20 Cm , Foam Dressing For Sacral And Other Pressure Sores Four Layer Dressing With Outermost Breathable Film, Moisture Control Layer And A Absorbant Layer 10 X 10 Cm , Silk Like Cloth Tape With Strong Adhesive 1.25 Cmx 9 Meters , Silicone Adhesive Tape Which Is Painless To Remove From The Skin . Size Of 2.5 Cm X 1.3 M , Silicone Adhesive Tape Which Is Painless To Remove From The Skin . Size Of 5 Cm X 1.3 M , Thromboembolism Prevention Stocking, Thigh To Ankle Level, Various Sizes For Patients In Icu, Immobile Patients. It Should Have Graduated Pressure Fit. Snug Fit. (L,M,S) (500 - M 50 - L 50 - S) , Artificial Dural Graft Non-Biological/ Synthetic, Biocompatible, Implantable, Artificial Dural Graft. Sewable To Normal Dura. Should Be Impervious To Fluid. For Permanent Implant. Should Lead To Minimal Adhesion Formation And Tissue Reaction. Expanded Polytetrafluoroethylene (Eptfe) Preferred. Size - Minimum 10 X 10 Cm , Artificial Dural Graft Non-Biological / Synthetic, Biocompatible, Implantable, Artificial Dural Graft. Sewable To Normal Dura. Should Be Impervious To Fluid. Material Should Be Absorbable (Like Poly L Lactic Acid) And Biomimetic Microstructure For Tissue Regeneration.For Permanent Implant. Should Lead To Minimal Size Minimumadhesion Formation And Tissue Reaction. Size Minimum 10X10 Cm , Reactive Polymer Based Multilaminate Adhesive Film For Protecting Dural Suture Line From Csf Leak, Which Is Biocompatible And Slowly Resorbed. Should Adhere To Dural Surface By Electrostatic Interaction. Less Than 50 X 50Mm Size Sterile Ready To Use , Reactive Polymer Based Multilaminate Adhesive Film For Protecting Dural Suture Line From Csf Leak, Which Is Biocompatible And Slowly Resorbed. Should Adhere To Dural Surface By Electrostatic Interaction.More Than 50 X 50Mm Size Sterile Ready To Use , Soft Nasal Pack With Breathing Hole After Endoscopic Nasal Surgery (Polyvinylalcohol Material) , Soft Nasal Pack Without Breathing Hole After Endoscopic Nasal Surgery (Polyvinylalcohol Material) , Foley Catheter With Antibacterial Coating Of Gold, Palladium And Silver Which Should Act By Virtue Of A Galvanic Effect Inhibiting Biofilm Formation.Silicone . [100% Pure Silicone, 2 Way Bulb]Exact Sizes And Quantities Required Will Be Mentioned At The Time Of Purchase Order And Hence Please Quote A Uniform Price For All Available Sizes Ranging From 6F To 18 F. The Product Should Have Randomized Controlled Data To Show That It Reduces Urinary Tract Infection , Foley Catheter With Antibacterial Coating Of Gold, Palladium And Silver Which Should Act By Virtue Of A Galvanic Effect Inhibiting Biofilm Formation.[Latex With 2 Way Bulb]Exact Sizes And Quantities Required Will Be Mentioned At The Time Of Purchase Order And Hence Please Quote A Uniform Price For All Available Sizes Ranging From 6F To 18 F. The Product Should Have Randomized Controlled Data To Show That It Reduces Urinary Tract Infection , Silicone Balloon Catheter For Intracranial Neuroendoscopy 3 Or 4 F (Fogarty Catheter) , Neurosurgical Patties Sterile, Ready To Use Cotton Patties, In Sterile Packaging. Size7x2 Cm, Each Pack Should Contain At Least 10 Patties , Neurosurgical Patties Silicone Transparent, Threaded Radio-Opaque. , Perforator Adult Size With Plunge Guard (Single Use, Disposable) Perforator With Inherent Mechanism To Stop A Plunge Once Dura Is Reached. Should Be Compatible With Hudsons Brace Available In Jipmer. If Not, You Must Provide A Compatible Hudson Brace For Every 100 Units Placed. , Perforator Pediatric Size With Plunge Guard (Single Use, Disposable) Perforator With Inherent Mechanism To Stop A Plunge Once Dura Is Reached. Should Be Compatible With Hudsons Brace Available In Jipmer. If Not, You Must Provide A Compatible Hudson Brace For Every 100 Units Placed. , Perforator Adult Size With Plunge Guard (Reusable, Sterilizable) Perforator With Inherent Mechanism To Stop A Plunge Once Dura Is Reached. Should Be Compatible With Hudsons Brace Available In Jipmer, Otherwise Brace To Be Provided Free Of Cost For Every Hundred Units Placed. , Perforator Pediatric Size With Plunge Guard (Reusable, Sterilizable) Perforator With Inherent Mechanism To Stop A Plunge Once Dura Is Reached. Should Be Compatible With Hudsons Brace Available In Jipmer, Otherwise Brace To Be Provided Free Of Cost For Every Hundred Units Placed , Ventriculoperitoneal Shunt [Adult Size, Pressure: High/Medium/Low] Burr Hole Design Of Dome Chamber And Valve With Diaphragm Type Valve. Chamber Should Sit On The Burr Hole Which Allows Aspiration Of Csf If Required. Biocompatible Material. The Part That Is Placed On The Burr Hole Should Have A Low Profile (Very Important). Valve Seating Interface Of Dissimilar Polymers. Valve Seating Interface Of Dissimilar Polymers (Will Be Rejected If It Is Not A Burr Hole Design Or If The Chamber Is Not Low Profile) .(High - 25 M - 100 Low - 25) , Ventriculoperitoneal Shunt [Paediatric Size, Pressure: High/Medium/Low] Burr Hole Design Of Dome Chamber And Valve With Diaphragm Type Valve. Chamber Should Sit On The Burr Hole Which Allows Aspiration Of Csf If Required. Biocompatible Material. The Part That Is Placed On The Burr Hole Should Have A Low Profile (Very Important). Valve Seating Interface Of Dissimilar Polymers. Valve Seating Interface Of Dissimilar Polymers (Will Be Rejected If It Is Not A Burr Hole Design Or If The Chamber Is Not Low Profile)(High - 25 M - 100 Low - 25) , Ventriculo Peritoneal Shunt Chabra Split Valve Type Adult; The System Should Be Supplied Complete With A Ventricular Catheter Around 15 Cm Long, A Unitized Shunt Aassembly With A Distal Catherter And Two Straight Connectors In Peel-Open Packs. The Pack Can Be Sterlized By Eto.(High 10, Medium 50 Low 10) , Ventriculo Peritoneal Shunt Chabra Split Valve Type Pediatric; The System Should Be Supplied Complete With A Ventricular Catheter Around 15 Cm Long, A Unitized Shunt Aassembly With A Distal Catherter And Two Straight Connectors In Peel-Open Packs. The Pack Can Be Sterlized By Eto. (High 10,Medium 50 Low 10) , Ventriculoperitoneal Shunt Antibacterial [Medium Pressure, Adult / Paediatric Size] Antibacterial Agents Should Be Incorporated Within Substance Of The Shunt Material [Not Coated] Which Elutes To The Outside Of The Shunt As Well As Within Lumen To Reduce Chances Of Shunt Infection; Two Different Antibiotic Agents Should Be Impregnated. The System Should Be Supplied Complete With A Ventricular Catheter Around 15 Cm Long, A Unitized Shunt Aassembly With A Distal Catherter And Two Straight Connectors In Peel-Open Packs. The Pack Can Be Sterlized By Eto. (Adult - 20 Paediatric - 20) , Ventriculoperitoneal Shunt With An Antisiphon Device Built Into It (Two Ball Design); The System Should Be Supplied Complete With A Ventricular Catheter Around 15 Cm Long, A Unitized Shunt Aassembly With A Distal Catherter And Two Straight Connectors In Peel-Open Packs. The Pack Can Be Sterlized By Eto. , Ventriculoperitoneal Shunt With An Antisiphon Device Built Into It (Three Ball Design); The System Should Be Supplied Complete With A Ventricular Catheter Around 15 Cm Long, A Unitized Shunt Aassembly With A Distal Catherter And Two Straight Connectors In Peel-Open Packs. The Pack Can Be Sterlized By Eto. , Ventriculoperitoneal Shunt With An Antisiphon Device Built Into It (Four Ball Design); The System Should Be Supplied Complete With A Ventricular Catheter Around 15 Cm Long, A Unitized Shunt Aassembly With A Distal Catherter And Two Straight Connectors In Peel-Open Packs. The Pack Can Be Sterlized By Eto. , Y Connector For Ventriculoperitoneal Shunt Which Can Be Attached To A Shunt To Drain A Loculation Or A Separate Cyst , Antibacterial External Ventricular Drainage Catheter. Antibacterial Agents Should Be Incorporated Within Substance Of The Catheter Which Is Placed In Brain To Drain Csf [Not Coated] Which Elutes To The Outside Of The Catheter And Within Lumen To Prevent Infection; Two Different Antibiotic Agents Should Be Impregnated. Should Be Translucent With Depth Markings. , Programmable Ventriculoperitoneal Shunt With External Programming Device For Use In Normal Pressure Hydrocephalus, 10 Mm Pressure Increment Settings. Programming Device Should Be Made Available In Jipmer As And When Requested With 24 Hour Prior Notice (Email Or Phone Call) , Programmable Lumboperitoneal Shunt With External Programming Device For Use In Normal Pressure Hydrocephalus, 10 Mm Pressure Increment Settings. Programming Device Should Be Made Available In Jipmer As And When Requested With 24 Hour Prior Notice (Email Or Phone Call) , Microsensor Transducer (Single Use, Disposable) For Monitoring Intracranial Pressure In The Brain Parenchyma (It Should Be Compatible With Available Monitor In Jipmer Or A Monitor Supplied Free Of Cost With The Reusable Microsensor Transducer Cable) The Cable Should Relay Information Electronically Rather Than Through A Hydrostatic Column Or Fiberoptics. , Ventricular Catheter And Pressure Transducer For Icp Monitoring Compatible With The Above Monitor (Or With Any Available Monitor In Jipmer Or A Monitor Supplied Free Of Cost With The Ventricular Catheter And Pressure Transducer) And Microsensor Cables , Single Use Transducer Cable (Parenchymal Or Subdural Or Ventricular) Compatible With The Icp Monitor That You Have Quoted In The Non-Consumable Section. , Implantable Ommaya Reservoir System Implantable Ommaya Reservoir System Of Two Different Sizes With Ventricular Catheter. Capable Of Tapping From Reservoir Percutaneously Or For Instilling Drugs , Lumboperitoneal Shunt System Implantable Lumbo Peritoneal Shunt System With Touhey Needle And Connectors , Lumbar Drain Set , External Ventricular Drainage System Which Should Include Ventricular Catheter, Connecting Tubes, Leak Proof Drainage Bag With Volume Markings And Built In Csf Pressure Scale {In A Sterile And Ready To Use Pack.} , Gigli Saw Wire Cutter For Craniotomy Should Not Fray/Break On Using. Sterilizable. Small Round Low Profile Loops At Either End. [Identical Sample Should Be Provided Before Selection] , Polypropylene Monofilament Suture Of Size 8-0 With Atraumatic Swaged Needle , Double Armed , Polypropylene Monofilament Suture Of Size 10-0 With Atruamatic Swaged Needle For Microvascular Anastamosis , Double Armed , Fibrin Sealant/Glue - Glue For Use In Neurosurgery To Prevent Csf Lead Based On Fibrin Coagulum Formed On Mixing Fibrinogen , Thrombin And Synthetic Aprotinin Components In Easy To Apply Chamber And Nozzle System. Dual Tip Syringe System And Vials With Sterile Water For Reconstitution Should Be Part Of The Package. Total Quantity Should Be At Least 1 Ml After Generation Of Fibrin. Components, If Derived From Pooled Or Single Donor Human Blood Should Be Free From All Known Pathogens. (Any Agitating/Warming Device Required To Mix The Glue Should Be Provided During Use And Kept In Neurosurgery Ot ) , Hemostatic Activated Regenerated, Oxidised Cellulose For Intraoperative Hemostasis In A Powder Form (3G) Which Can Be Put In An Operative Cavity Using A Sterile Applicator In Manually Activated Pump , Hemostatic, Activated Regenerated Cellulose For Intra-Operative Hemostasis In Mesh Form , Hemostatic Activated Regenerated Cellulose For Intraoperative Hemostasis In Fibrillar Form In Aluminium Package To Protect From Heat, Light And Moisture. Should Have Us Fda Or Ce Or Equivalent Indian Standards. There Should Be Published Animal Or Human Studies For Clinical Efficacy. , Injectable Hemostatic Agent Prefilled Syringe With Haemostatic Matrix Agent With Human Thrombin And Calcium Chloride For Intraoperative Use.5 Ml , Cranioplasty Material Using Heat Mouldable High Density Porous Polyethylene Material With Pore Size Of 100 Microns Or Less For Tissue Integration. Size 12 X 17 Cmof 6 Mm Thickness. , Customized Craniomaxillary Repair System Using Peek Material Which Can Be Implanted. The Material Should Be Fabricated According The Ct Scan Reconstruction Data Of A Particular Patient. Quote Per Milliliter Volume Of The Material , Customized Craniomaxillary Repair System Using Titanium Material Which Can Be Implanted. The Material Should Be Fabricated According The Ct Scan Reconstruction Data Of A Particular Patient. Quote Per Milliliter Volume Of The Material , Customized 3 D Printed Rigid Model Based On Ct Or Mri Data Of Particular Patient For Planning Operative Approach. Should Include Soft Tissue Structures And Fine Structures Like Vessels, And Internal Architecture Of Temporal Bone. Price Should Be Mentioned Per Ml (Cm3) Of Final Product. Quote Per Milliliter Volume Of The Material , Customized 3 D Printed Rigid And Flexible Model Based On Ct Or Mri Data Of Particular Patient For Planning Operative Approach. Should Be Include Soft Tissue Structures And Fine Structures Like Vessels, And Internal Architecture Of Temporal Bone. Price Should Be Mentioned Per Ml (Cm3) Of Final Product. Quote For Milliliter Volume Of The Material , Injectable Hemostatic Agent Prefilled Syringe With Haemostatic Matrix Agent With Human Thrombin And Calcium Chloride For Intraoperative Use.6-10 Ml , Bone Wax Easily Squashable, Bone Wax For Sealing Bleeding Bone Edges, Sterile And Ready To Use In Tear Open Packages. Should Not Stick To Glove. , Cranial Mapper - Disposable Malleable Ct Scan-Based Cranial Mapper For Armless, Frameless Intraoperative Localization For Doing Cranial Surgery. , Open-Door Laminoplasty System (Titanium) - It Should Offer Intraoperative Adaptability Through Expansive Plate Options; Instrumentation Should Be Provided For The Surgeries With Various Screws Options. Quote For The Set Of Single Level Plate, And Four Screws. , Cervical Titanium (Disc) Spacer With Sharp Teeth And Graft Packing Window Along With Varous Size Options. Should Have An Anatomical Shape To Promote Maintanance Of Cervical Lordosis. Instrumentation Should Be Provided For The Surgeries. , Cervical Peek (Disc) Spacer With Sharp Teeth And Graft Packing Window Along With Varous Size Options In Polyetheretherketone (Peek). Should Have An Anatomical Shape To Promote Maintanance Of Cervical Lordosis. Instrumentation Should Be Provided For The Surgeries. , Anterior Cervical Interbody Spacer (Titanium) With Integrated Fixation Screws. Spacer Should Have With Sharp Teeth And Graft Packing Window Along With Varous Size Options. Should Have An Anatomical Shape To Promote Maintanance Of Cervical Lordosis. Instrumentation Should Be Provided For The Surgeries. Titanium Spacer With Two Titanium Screws And One Integrated Locking Screw (1 Set) , Anterior Cervical Interbody Spacer (Peek Integrated With Titanium) With Integrated Fixation Screws. Spacer Should Have With Sharp Teeth And Graft Packing Window Along With Varous Size Options In Polyetheretherketone (Peek). Should Have An Anatomical Shape To Promote Maintanance Of Cervical Lordosis. Instrumentation Should Be Provided For The Surgeries. Peek And Titanium Integrated Spacer With Two Titanium Screws And One Integrated Locking Screw (1 Set) , Anterior Cervical Plate And Screws (Titanium) - Single Level; Anterior Cervical Plate System With Attached Locking Mechanism And Choice Of Fixed Angle Screws For Standard Cases Or Variable Angle Screws For Ease Of Implantation In Complex Cases. System Should Allow The Surgeon The Versatility Of Creating Fixed, Variable Or Hybrid Construct Intraoperatively. Plate Should Be 2.5Mm Thick. Plate Should Have Medial/Lateral Radius Of Curvature And Lordotic Radius Of Curvature. Instrumentation Should Be Provided For The Surgeries With Various Screws Options. Quote For The Set Of Single Level Plate, Four Screws And Two Integrated Locking Screws. , Anterior Cervical Plate And Screws (Titanium) - Two Level; Anterior Cervical Plate System With Attached Locking Mechanism And Choice Of Fixed Angle Screws For Standard Cases Or Variable Angle Screws For Ease Of Implantation In Complex Cases. System Should Allow The Surgeon The Versatility Of Creating Fixed, Variable Or Hybrid Construct Intraoperatively. Plate Should Be 2.5Mm Thick. Plate Should Have Medial/Lateral Radius Of Curvature And Lordotic Radius Of Curvature. Instrumentation Should Be Provided For The Surgeries With Various Screws Options. Quote For The Set Of Two Level Plate, Four Screws And Two Integrated Locking Screws. , Anterior Cervical Plate And Screws (Titanium) - Three Level; Anterior Cervical Plate System With Attached Locking Mechanism And Choice Of Fixed Angle Screws For Standard Cases Or Variable Angle Screws For Ease Of Implantation In Complex Cases. System Should Allow The Surgeon The Versatility Of Creating Fixed, Variable Or Hybrid Construct Intraoperatively. Plate Should Be 2.5Mm Thick. Plate Should Have Medial/Lateral Radius Of Curvature And Lordotic Radius Of Curvature. Instrumentation Should Be Provided For The Surgeries With Various Screws Options. Quote For The Set Of Three Level Plate, Four Screws And Two Integrated Locking Screws. , Expandable Cage (Titanium) - An Integrated Vertebral Body Replacement Device (Cervical, Thoracic And Lumbar) That Provides Anterior Column Support And Is Designed To Prevent Implant Dislodgement. The Spacer Should Have Integrated Titanium Plates And Screws For Additional Stabilization Between The Vertebral Bodies And The Spacer With An Integrated Locking Mechanism. The Implants Should Be Available In A Wide Range Of Footprints, Heights, And Lordotic/Kyphotic Angles In Titanium. Maximized Expansion Ranges And Modular Endplates Allow Surgeons To Customize Each Implant To The Patient. Instrumentation Should Be Provided For The Surgeries With Various Screw Options. Quote For The Set Of Cage, Four Screws, And Two Integrated Locking Screws. , Expandable Cage (Peek With Integrated Titanium) - An Integrated Vertebral Body Replacement Device (Cervical, Thoracic And Lumbar) That Provides Anterior Column Support And Is Designed To Prevent Implant Dislodgement. The Spacer Should Have Integrated Titanium Plates And Screws For Additional Stabilization Between The Vertebral Bodies And The Spacer With An Integrated Locking Mechanism. The Implants Should Be Available In A Wide Range Of Footprints, Heights, And Lordotic/Kyphotic Angles In Polyetheretherketone (Peek). Maximized Expansion Ranges And Modular Endplates Allow Surgeons To Customize Each Implant To The Patient. Instrumentation Should Be Provided For The Surgeries With Various Screw Options. Quote For The Set Of Cage, Four Screws, And Two Integrated Locking Screws. , C1 –C2 Joint Spacer(Titanium). Instrumentation Should Be Provided For The Surgeries With Various Size Options. Quote For The Set Of Two Spacers. , Multi-Axial Lateral Mass Screw Implants (Titanium) For Posterior Cervical Spine Fixation. These Multi-Axial Lateral Mass Screws Should Be Compatible With 3.2Mm And 3.5Mm Rods, Up To 45-Degree Angulations With Index Markers On Saddles To Easily Identify The 45-Degree Relief Notches, Along With 2.5Mm Hex Internal Buttress Threaded Set Screws. Instrumentation Should Be Provided For The Surgeries With Various Screw Options. Quote For The Set Of Two Screws And A Single Rod. , Lumbar Interbody Implant(Peek) For Use In Posterior Lumbar Interbody Fusion (Plif) Or Transforaminal Lumbar Interbody Fusion (Tlif) Procedures And It Should Be Compatible With Open, Mini Or Mast Technique Approaches. Implants Should Be Made Of Polyetheretherketone (Peek), Convex Shaped, Should Have Tantalum Markers, Tooth Like Surface And Bullet Tip. Implants Should Have Sterile Pack. Length 22Mm And Height 10Mm With Internal Graft Volume Of 0.5Cc. Posterior Instrumentation Should Be Provided At The Time Of Surgery , Adjustable Occipital Plate (Titanium) For Occipito Cervical Junction Surgery With Multiple Screw Holes To Accept 4.5 Mm, 5.0 Mm Occipital Bone Screws, Pre-Contoured Occipital Rods Or Occipital Adjustable Rods. Instrumentation Should Be Provided For The Surgeries With Various Screw Options. Quote For The Set Of One Plate, Two Rods, Six Occipital Screws And Locking Screws (Titanium). , Multiaxial Pedicle Screw (Titanium) - Multi Axial Titanium Pedicle Screws With Diameter Range Of 4.5 Mm, 5.5 Mm, 6.5Mm And The Lengths Ranging From 30Mm To 50 Mm With Buttress Threaded Break Off Set Screws To Secure The Rod In To The Head Of The Implant. Should Be Compatible With The 5.5Mm Rod System. Instrumentation Should Be Provided Along With The Rods And Various Sizes Of Screws For The Surgeries. Quote A Uniform Rate For A Construct Set Of Four Screws And Two Rods. (Do Not Quote For A Single Screw Or Rod). , Bone Substitutes This Should Be An Rhbmp-2 (Recombinant Human Bone Morphogenetic Protein-2) Formulation Combined With A Bovine-Derived Absorbable Collagen Sponge (Acs) Carrier. , Hydroxyapatitile Isothermic Bone Substitute Which Can Set In A Wet Field (10 Cc) , Medical-Grade Polyporous Resorbable Ceramic Granules With 15% Hydroxypatite+85% Beta-Tricalcium Phosphate. (10Cc) , Self Drilling Titanium Screws With Length Of 12 Mm,14 Mm,16 Mm , 18Mm For Anterior Cervical Plate Fixation - 1 Set (4 Screws). Instrumentation Should Be Provided For The Surgeries With Various Screws Options. Quote For A Set Of Four Screws. (12 Mm, - 20 Nos 14 Mm - 20 Nos 16 Mm- 20 Nos 18Mm- 20 Nos) , Philadelphia Type Neck Collars With Hole For Ventillation Through Tracheostomy Tube, Size: Large/Medium/Small(L - 25 M -50 S -25) , Halo Vest Halo Ring, Titanium Pins And Vest For Extended Immobilization Of Upper Cervical Spine. Custom Fit To Be Ensured As And When Necessary. System Should Be Mri Compatible With Minimal Imaging Artifacts. Tool Kit For Applying And Removing. Demonstration And Technical Assistance Required. , Synthetic Bone Paste Consists Of Pure Nanocrystalline Hydroxyapatite That Are Less Than 20 Nanometers In Size Embedded In A Matrix Of Sterile Water, With Osteoconductive Properties, Delivered In Syringe (5Cc) , Miniplate And Screw System For Fixing Bone Flap During Craniofacial Surgery. Quote For A Set Of A 16 Hole Plate (Profile Height 0.8 Mm) With 10 Self Drilling Screws (2.0 X 5 Mm) And One Emergency Screw (2.3 Mm X 6 Mm)(Self Drilling Nature And The Ease Of Application To Be Demonstrated). Each Colour Coded) Minor Variation In Dimension Acceptable , Self Tapping 1.5 Mm Screws With A Conical Core Design. The Screw Should Have A Reinforced Neck Allowing Improved Troque Transmission And Easy Removal. The Screw Head Profile Should Not Be More Than 0.6 Mm.Minor Variation In Dimension Acceptable , Dynamic Malleable Titanium Mesh Which Can Be Contoured Using A Mesh Bender. Thickness Should Be 0.3 Mm Profile Height. 120 X120 Mm Surface Area Minor Variation In Dimension Acceptable , Low Profile (0.5 Mm) Two Hole 16 Mm Bar Plate With Two Self Drilling Screws (1.5 X 5 Mm), Grade Ii Titanium. One Driver Should Be Provided On Loan Based For The Purpose Of Fixing The Screwsminor Variation In Dimension Acceptable , Low Profile (0.6 Mm)Two Hole 12 Mm Bar Plate With Two Self Drilling Screws (1.5 X 5 Mm), Grade Ii Titanium.One Driver Should Be Provided On Loan Based For The Purpose Of Fixing The Screws Minor Variation In Dimension Acceptable , Bone Flap Fixation System For Fixing Bone Flap Using Titanium Or Similar Biocompatible Material With Thin Profile, Preferably With Compressing Plates On Both Sides Of Burr Hole. Quote For One Clamp 11-16 Mm. All Instruments On Loan Basis. , Burr Hole Button For Cosmetic Occlusion Of Burr Holes With 3 Nos. Of Screws , Drape, Endoscopy Generaltiburon Surgical Drape Fabric Absorbent Impervious Reinforcement, 16" X 38 1/2" Two Clear Poly Troughs With Hook & Loop Closure, 11 1/8" X 30" Hook & Loop Cord-Holding Tabs Fenestration, 10" X 11" Armboard Covers , Craniotomy Drape Central Round Integrated Self Adhesive Transparent (Not Just Transcluscent) Area Of Diameter Greater Than 20 Cm, With Surrounding Flange, Tubing For Drainge Of Blood And Wash Fluid, Rest Of The Non-Woven Material Of The Drape Should Be Fluid Impermeable Of Dimensions 2X1.6 M. Capable Of Covering The Patients’ Torso. , Ventriculoperitoneal Shunt Drape For Ventricular Shunt Surgery Covering Head To Abdomen With Transparent Sticking Operation Site Plastic Incise Drape , Laminectomy Drape Water Resistant Drape With Central Iodine Impregnated Transcluscent Adhesive Patch Which Can Cover From Head To Toe For Laminectomy , Iodine Impregnated Adhesive Incise Drape With Paper Background , Face Mask With Shield : Surgeon Face Mask With Clear Plastic Visor Shield Built In, With Malleable Nose Clip, Latex Free. Should Prevent Aerosol Or Droplet Splash On Eyes. (Transparent Distortion Free Optical Characteristics, Crease Free Nature Of Visor Is Absolutely Important) , Microscope Drape Transparent Thin Sterile Microscope Drape For Use With Oh5 M720 Operating Microscope . The Drape Should Fit Properly[Sample To Be Provided To Assess Suitability] , Microscope Drape Transparent Thin Sterile Microscope Drape For Use With Moller Wedel Hir700 Neurosurgical Operating Microscope. The Drape Should Fit Properly[Sample To Be Provided To Assess Suitability] , Microscope Drape Transparent Thin Sterile Microscope Drape For Use Withf40 Leica Microscope. The Drape Should Fit Properly[Sample To Be Provided To Assess Suitability] , C Arm (Image Intensifier) Transparent Sterile Drape , Universal Camera Drape 18X250 Cms Telescopic Folding, Separate Tape Strip , Povidone Iodine Spray In Canisters For Preparing Surgical Site , Raney Clips [Plastic] , Liga Clips, Small & Medium (100 Each) , Catheter Mount For Ventilator (Maquet Ventilator Compatible) , Nibp Cuff Compatible With L&T Starplus And Galaxy Multiparameter Monitor (Adult Size) , Nibp Cuff Compatible With L&T Starplus And Galaxy Multiparameter Monitor (Pediatric Size) , Nibp Cuff Compatible Withwipro Ge B450multiparameter Monitors (Double Tubing) - Adult Size , Nibp Cuff Compatible Withwipro Ge B450multiparameter Monitors (Double Tubing) - Pediatric Size , Spo2 Sensor And Cable Compatible With L&T Starplus And Galaxy Multiparameter Monitors , Spo2 Sensor And Cable Compatible With Wipro Ge B450multiparameter Monitors , 3 Lead Ecg Cable Button Ends Detachable Compatible With Starplus, Galaxy, And Wipro Ge B450 Monitors , Nibp Hose Assembly Compatible With Wipro Ge B450 Monitors , Oxygen Mask With Connection Adaptor , O2 T Piece , Tracheal Mask With Connector , Non Invasive Oxygen Mask , Bacterial Filter (Compatible With Maquet Servo Ventilators In Neurosurgery I.C.U.) , Burette Set For Pediatric Iv Fluid Infusion , Transparent Contoured Tubular Retractor For The Brain To Do Endoscopic Or Microsopic Procdures. It Should Have Depth Marking, Holder To Put On A Retractor Arm, A Lockable Obturator Which Can Be Removed. The Length Should Be About 10 Cm (Plus Or Minus 1 Cm) And The Internal Diameter Should Be 20 Mm (Plus Or Minus 2 Mm) , Silicone Separator For Decompressive Craniectomy To Maintain A Plane For Future Cranioplasty. The Silicone Film Should Have A Thickness Of 1 To 1.5 Mm And Should Have Slits Or Perforations To Allow Fluid To Go Through. 15 X 20 Cm Size. , Sequential Pneumatic Compression Sleeve /Sheathfor Use In Dvt Prophylaxis. The Sleeve Should Be Upto Thigh Starting From Calf With Straps To Suit Lower Limb And Various Girths Should Be Washable And Reusable For A Single Patient. Should Be Compatible With The Kendall Pump Device Already Available With Us. , Patient Warming Blanket, Thermally Insulated Silver Coloured For Use With Warming Air System Adult Size (Must Be Compatible With Currently Available Warmer In Jipmer Neurosurgery , Patient Warming Blanket, Thermally Insulated Silver Coloured For Use With Warming Air System Pediatric Size (Must Be Compatible With Currently Available Warmer In Jipmer Neurosurgery , 4-Contact, Strip, Eeg Subdural Electrode.Platinum, 4Mm Dia With 10Mm Spacing Between Contacts, Withconnector Blocks (10 Nos / 1 Box) And Compatible Cable , 6-Contact, Strip, Eeg Subdural Electrode.Platinum, 4Mm Dia With 10Mm Spacing Between Contacts, Withconnector Blocks (10 Nos / 1 Box) And Compatible Cable , 6-Contact Depth Electrode.Platinum With 10Mm Spacing Between Contacts, Withconnector Blocks (10 Nos / 1 Box) And Compatible Cable , 24 Contacts 4X6 Multi-Stripsubdural Implantable Eeg Electrode Series With Connector Blocks And Cables , Depth Implantable Stereotactic Eeg (Stereo-Eeg) Electrode 4 Contact(1*4)Depth Implantable Eeg Electrode (Platinum / Iridium Contact) With Anchor Bolt Cap. Ring Contact Size Of 2 Mm. Outer Diameter Should Be 0.8 Mm Or Less , Depth Implantable Stereotactic Eeg (Stereo-Eeg) Electrode 8 Contact Depth Implantable Eeg Electrode (Platinum / Iridium Contact) With Anchor Bolt Cap. Ring Contact Size Of 2 Mm. Outer, Distal Diameter Should Be 0.8 Mm Or Less , Guidance Screw, 20 Mm For Stereo-Eeg Electrode, Compatible With The Electrodes Mentioned Above , Guidance Screw, 25 Mm For Stereo-Eeg Electrode, Compatible With The Electrodes Mentioned Above , Guidance Screw, 30 Mm For Stereo-Eeg Electrode, Compatible With The Electrodes Mentioned Above , Extension Cable For 4 Contact Stereo-Eeg Electrode , Extension Cable For 5 Contact Stereo-Eeg Electrode , Extension Cable For 8 Contact Stereo-Eeg Electrode , Extension Cable For 10 Contact Stereo-Eeg Electrode , Extension Cable For 18 Contact Stereo-Eeg Electrode , Cleaning And Lubricant Solution For Electric Drill, Based On Food Grade Mineral Oil And Propellant Base ("Pana Spray" Or Equivalent). 500 Ml Can , Instrument Lubricant Concentrate, With Antimicobial Activity, 50Ml Capacity , Flexometallic Electromyography (Emg) Endotracheal Tube For Intraoperative Nerve Monitoring ] Quote A Uniform Price For Sizes From 6 To 9 Mm Diameters. Exact Quantitiess Of Each Type Required Will Be Mentioned In The Purchase Order (6Mm-5, 6.5Mm-20, 7Mm-20,7.5Mm-20,8Mm-10) , Endotracheal Tube With Low Pressure Low Volume Cuff And A Subglottic Aspiration Catheter Port Which Should Be Above The Cuff. The Cuff Should Be Shaped And Tapered In Such A Way That Secretions Accumulate In The Zone Between Tube And The Tapered Cuff To Prevent Microapiration. (Sizes 6.0 To 8.5) (6 - 50 6.5 -200 7.0 - 200 7.5 - 200 8 - 50 8.5 - 50) , Tracheostomy Tube With Low Profile Low Pressure Cuff With An Aspiration Catheter Port Which Help Aspirate Subglottic Secretions Above The Level Of The Cuff. The Cuff Should Be Shaped In Such A Way That Secretions Accumulate In The Zone Between Tube And Cuff. (6.5 - 100 7.0 - 100 7.5 - 100 8.0 -100) , Bougie For Endotracheal Tube Exchange (Tracheal Tube Introducer) , Outer Diameter 5.0Mm Length 700Mm Straight Tip, Reusable , Bougie For Endotracheal Tube Introduction For Difficulty Airway (Tracheal Tube Introducer) , Outer Diameter 5.0Mm 600Mm Length Coude Tip, Resuable , Indocyanine Green Dye For Microscope Integrated Video Angiography During Aneurysm Clipping 25 Mg Vials , Monopolar Hand Pieces Controllable By Both Hand Piece And Foot Switch Which Is Disposable (Compatible With Excel, Mallis And L&T Bipolar Machines) , Monopolar Microdissection Needle With 5 Micron Tungsten Tip For Precision Electrosurgery , Flexible Patient Contact Plate (Compatible With Excel, Mallis And L&T Bipolar Machines), Reusable. , Expanded Poly Tetraflouroethylene Eptfe (Teflon Patch) 0.4 Mm For Use In Microvascular Decompression. 1 X 1 Cm Size , Container For Sending Pathological Biopsy (100 Ml Capacity) , Sub-Cortical Suction Stimulator For Stimulating Subcortical White Matter While Resecting Gliomas To Elicit A Motor Evoked Potential Response. Compartable With Tom Systems In Jipmer Neurosurgery , Intra-Arterial Drug Infusion Catheters Non Thrombogenic Coated Long Catheters Of 160-170 Cms Length With 0.015, 0.0165 Inches Internal Diameter To Be Used As Indwelling Intra-Arterial Catheter For Drug Delivery In Internal Carotid Artery Over A Prolonged Period Of Time (Up To 100 Hours). , Surgeon Gown (Medium Size) Which Is A Fully Wrap Around Variety And Can Be Tied In Front, With Water, Alcohol Resistance. Outer Layer Spun Bound Repellant Layer With Inner Two Layers With Antibacterial Property (Melt Blown), And Innermost Layer For Fabric Strength (Spun Bound) Soft Elastic Wrist Cuff. Adjustable Neck Line Needed. Low Linting. Sample Absolutely Required. Must Meet Or Exceed En13795 Standards Or Else Will Not Be Considered.Quote Separately For Tape Covered Double-Stitched Seam Type Gown As Well As The One With Ultrasound Bonded Seam , Surgical Gloves : Polyurethane Inner Coating With Textured External Surface And Dark Coloured To Prevent Reflective Glare. Internal Surface Should Have Powder Free, Polymer Coated And Siliconated,Protein Less Than 30Micro Gram And Preferrable Thickness At Finge Is 0.18Mm.(6.0 - 50 6.5 -200 7.0 - 200 7.5 - 200 8-200) , Surgical Under Glove: Internal Surface - Polyurethane Coated & Moisturized Hydrasoft Coated, Preferable Finger Thickness 0.19Mm, Teal Green Coloured And Gamma Sterilized. Size: 7.0 & 7.5 , Urinary Drainage Bag (Urometer) For Collection Of Urine From Foley Catheter With Volume Measurement Compartment Separate From Bag Lines For As Little As 50 Ml So That Hourly Urine Output Can Be Monitored, Non-Return Valve And Transparent. , Self Contained Double Lumen Suction Catheter Which May Be Used For Endotracheal Suctioning On Ventilated Patients With Plastic Envelope Containing Threadable And Retractable Soft Blunt Nosed Catheter. A Thumb Depressable Switch To Initiate And Stop Suctioning When Connected To Wall Suction. Rotating Access Valve To Isolate The Airway During Closed Position. Simultaneous Irrigation And Suctioning Should Be Possible (Mandatory Requirement). Must Have A Port To Attach An Mdi Adaptor Along With An Mdi Adaptor Labels For Days Of Use Or To Indicate When To Replace. For Multiple Use Over A Period Of 3 Days Or More. Demo Absolutely Mandatory Before Selection And If There Is Any Leak Or Suboptimal Performance On Testing It Will Be Rejected. (Size: 12 French : 25Cms & 45Cms, 14 French : : 25Cms & 45Cms) , Forehead Spo2 Sensor (Disposable) For Detecting Oxygen Saturation Reliably In Patients With Low Perfusion And Low Saturation With Accuracy Down To 60 %. Head Band Should Be Provided. If Cables Are Required That Should Be Provided Free Of Cost On Loan Basis. It Should Have A Four Layers Adhesive. , Operation Trolley Drape Made Of Fluid (Water And Alcohol) Impermeable Drape Of Size 1.5 X 1.5 M Size & 1.5 X 2 Mm (En13795 Standard) , Silicone Tracheostomy Tube, Cuffless With Obturator, Speaking Hole, Sizes Of 4, 6 And 8 , Silicone Tracheostomy Tube, Cuffled With Obturator, Speaking Hole, Size Of 4, 6 And 8 , Medical Grade Silicone Rubber (Addition Cure Type Silicone Rubber Adding 50:50 Of Part A And B). Either Colourless Or Skin Colour. Should Cure In 24 Hours Or Faster In Oven. 1 Kg. Equivalent Of Aditya Silicone Material Seen At This Link Https://Www.Adityasilicone.Com/Product/Aditya-Silicone-Rubber-Rtv-M-10-Body-Parts-1-Kg/ , Incentive Spirometer Which Shows Exact Volumes Per Minute. Should Have A Marker Which Indicates The Desirable Rate Of Inspiration. It Should Ensure That Patient Inhales Rather Than Exhales. Should Have A Port For Connecting Oxygen While In Use. Should Have A Bed Rail Holding Loop Built Into The Device. Flow Setting 500 Ml To 4000 Ml/Sec , Incentive Spirometer Which Shows Exact Volumes Per Minute. Should Have A Marker Which Indicates The Desirable Rate Of Inspiration. It Should Ensure That Patient Inhales Rather Than Exhales. Should Have A Port For Connecting Oxygen While In Use. Should Have A Bed Rail Holding Loop Built Into The Device.; Low Flow Setting 100 Ml To 600 Ml/Sec, Suitable For Pediatric Patients Or Patients With Poor Reserve. , Skin Stapler Remover , Non-Glutaradehyde Based Floor Cleaning Agent For The Intensive Care Unit Using A Quarternary Ammonium Compound And Non Intonic Surfactants. Surfactants Should Be Biodegradable According To Eu Detergent Guideline. A 0.5% Solution Should Have En 1276 Bactericidal Activity Even With High Soiling. Quote For One Liter Of Pure Solution Which Will Give A 0.5% Solution With En1276 Activity. , Non Glutaraldehyde Based Enzymatic Cleaner With Disinfiectant Cleaning Solution. Quote For 500Ml Pack , Tubular Elastic Dressing Made Of Cotton And Elastane For Tight Dressing Of Scalp. , Hepa And Carbon Filter For High-End Air Purifier In The Non Consumable Section(Lowest Quote Will Be Based On The Combined Value Of Machine And Filter) , Non Woven Cohesive Bandage Which Is Breathable And Stretcheable 10 Cm Breadth X 4 Meters. It Should Stick To Itself So That Bandaging Can Be Done Without Typing , Clipping Or Taping. , Scalp (Head) Decontamination Cap Impregnated With Polyhexamethylene Biguanid In Gel Form. , Non Ionic Amphoteric Surfactant Based Cleaning Agent For Insturments And Neuroendoscopes. It Should Be Compaticle For Use In Ultrasonic Baths. 1% Solution In 500 Ml Bottles , Disinfectant Wipes For Surface Cleaning To Be Used In Neurosurgery Ot & Icu. Disinfectant Should Contain Ethanol, 2- Propranalol And 1 Propranalol With 90Pull Outs (12 X12 Inches) Which Are Lint Free . Should Be Aldehyde Free. , Disinfectant Wipes For Surface Cleaning Ato Be Used In Neurosurgery Ot & Icu Nd For Cleaning Ultrasound Probes. Disinfectant Should Contain Didecyldimethyl Ammoniium Choride And Quarternary Ammonium Compounds Which Are Active Against Mrsa , Yeasts And Papova /Polyoma Viruses. 80 Or More Pull Outs 29X22 Cm Size Approximately , Water Less, Brush Less Surgical Hand Antiseptic Containing Chlorhexidine Gluconate (1%) And Ethylalcohol (61 % W/W). The Product Must Be Fda-Nda Approved For Use As Water Less Surgical Scrub. 500 Ml Bottles. , Body Decontamination Wipes Impregnated With Polyhexanide. One Pack Should Have 10 Wipes. , Alcohol Free Barrier Film That Can Be Sprayed On The Skin Which Acts By Forming An Impermeable Polymer Film. It Should Remain On Skin For 72 Hours. In 28 Ml Spray Bottle . , A Wearable, Wireless, Disposable, Vital Signs-Monitoring Device That Can Be Attached To The Patients Chest For At Least Five Days. It Should Be Powered By An In-Built Cell Like A Lithium Battery. It Should Pick Up At Least Two Lead Ecg, Heart Rate, Respiration Rate, Skin Temperature, Spo2, And The Patients Posture. Ingress Protection Should Be At Least Ip24. Weight Should Be Less Than 35 Grams. The Device Should Not Be Harmed By A Defibrillation Current If Used On The Patient. It Should Communicate With The Internet Using Wlan Or Blue Tooth Gateway Or Similar Technology To Give An Online Interface. The Vital Signs Should Be Displayed On A Web Page Accessible Using The Internet On A Desktop Computer Or Mobile Phone. The Vendor Should Set Up The Networking At The Place Where The Patient Is Wearing It, And It Should Have A Reach Of At Least 15 Meters. , 1)Non Rechargeable Implantable Neuro Stimulator(Mri Compatible ) : 1)Dual-Channel Implantable Neurostimulator For Use With Deep Brain Stimulation (Dbs) Leads, And Patient Programmer. Advanced Programming Features For Patients And Clinicians. A)Mri Campatible *, B)Number Of Defined Groups 1 To 4 C)Number Of Programs Per Group 1 To 4 D)Electrode Configurationb 1 To 4 Electrodes Per Lead As Anode, Cathode, Or Off E)Case Defined As Anode Or Off F)Amplitude (Voltage Mode) 0 To 10.5 V With 0.05 V Or 0.1-V Resolution G)Amplitude (Current Mode) 0 To 25.5 Ma With 0.1-Ma Resolution H)Amplitude – Upper Patient Limit By Hemisphere: I)Tracking Limit: +0 To +2 (0.2 Resolution); +2 To +4.5 (0.5Resolution) J)Amplitude – Lower Patient Limit By Hemisphere: K)Tracking Limit: -0 To -2 (0.2 Resolution); -2 To -4.0 (0.5Resolution); Full Rangec L)Pulse Width 60 To 450 ?S (10 ?S Resolution) M)Pulse Width – Upper Patient Limit Tracking Limit: +0 To +100 ?S (10-?S Resolution) N)Pulse Width – Lower Patient Limit Tracking Limit: -0 To -100 ?S (10-?S Resolution) O)Rate (Voltage Mode) 2 To 250 Hz (Resolution: 1 Hz From 2 Hz To 10 Hz, 5 Hzfrom 10 Hz To 250 Hz)D P)Rate (Current Mode) 30 To 250 Hz (5-Hz Resolution)Drate – Upper Patient Limit Tracking Limit: +0 To +50 Hz (10-Hz Resolution)Rate – Lower Patient Limit Tracking Limit: -0 To -50 Hz (10-Hz Resolution) Q)Softstart/Stop Off, On: 1, 2, 4, Or 8 Second Ramp Duration R)Cycling Off, On: 0.1 S To 24 Hr (Resolution: 0.1 S From 0.1 S To1 S, 1 S From 1 S To 59 S, 1 Min From 1 Min To 59 Min, 1 Hrfrom 1 Hr To 24 Hr), Non Rechargeable , 2)Rechargeable Implantable Neuro Stimulator (Mri Compatible ) : Dual-Channel Rechargeable Implantable Neurostimulator For Use With Deep Brain Stimulation (Dbs) Leads, And Dbs Patient Programmer And Patient Recharger System. Advanced Programming Features For Patients And Clinicians. A)Mri Campatible , B)Number Of Defined Groups 1 To 4B No More Than 16 Programs May Be Defined Within The 4 Groups. C)Number Of Programs Per Group 1 To 4B D)Electrode Configuration Up To 4 Electrodes As Anode, Cathode, Or Off E)Case Defined As Anode Or Off F)Amplitude (Voltage Mode) 0 To 10.5 V With 0.05 V Or 0.1-V Resolution G)Amplitude (Current Mode) 0 To 25.5 Ma With 0.1-Ma Resolution H)Amplitude – Upper Patient Limit By Hemisphere: I)Tracking Limit: +0 To +2 (0.2 Resolution); +2 To +4.5 (0.5Resolution) J)Amplitude – Lower Patient Limit By Hemisphere: K)Tracking Limit: -0 To -2 (0.2 Resolution); -2 To -4.0 (0.5Resolution); Full Rangec L)C Full Range = -10.5 V (Voltage Mode); -25.5 Ma (Current Mode) M)Pulse Width 60 To 450 ?S (10-?S Resolution) N)Pulse Width – Upper Patient Limit Tracking Limit: +0 To +100 ?S (10-?S Resolution) O)Pulse Width – Lower Patient Limit Tracking Limit: -0 To -100 ?S (10-?S Resolution) P)Rate (Voltage Mode) 2 To 250 Hz (Resolution: 1 Hz From 2 Hz To 10 Hz, 5 Hzfrom 10 Hz To 250 Hz)D Q)D Rate Limited To 125 Hz When Two Programs Are Active On A Single Lead. R)Rate (Current Mode) 30 To 250 Hz (5-Hz Resolution)D S)Rate – Upper Patient Limit Tracking Limit: +0 To +50 Hz (10-Hz Resolution) T)Rate – Lower Patient Limit Tracking Limit: -0 To -50 Hz (10-Hz Resolution) U)Softstart/Stop Off, On: 1-, 2-, 4-, Or 8-Second Ramp Duration V)Cycling Off, On: 0.1 S To 24 Hr (Resolution: 0.1 S From 0.1 S To1 S, 1 S From 1 S To 59 S, 1 Min From 1 Min To 59 Min, 1 Hrfrom 1 Hr To 24 Hr), Rechargeable , 3)Patient Programmer A)Allows Patients With Neurostimulators To Check Therapy And Neurostimulator Battery Status, And Adjust Settings Or Change Programming Group According To Clinician-Determined Parameters. 1. Patient Programmer Technical Specifications: A)Power Source 2 Aaa Alkaline Batteries (Non-Rechargeable, Lr03) B)Operating Temperature +9 °C To +43 °C (+49 °F To+110 °F) C)Temperature Limitation -34 °C To +57 °C (-30 °F To+135 °F) D)Size Approximately 9.4 Cm X 5.6Cm X 2.8 Cm (3.7 In X 2.2 Inx 1.1 In)Weight, Including E)Batteries Approximately 111 G (3.9Oz.) F)Battery Life 2 Months (Average) For Alkaline Batteries G)Mode Of Operation Continuous , 4)Deep Brain Stimulation Leads : Quadripolar Leads For Delivery Of Electrical Impulses To The Target Region Of The Brain.One 4-Electrode Lead, For Use With Extension With In-Line Connector. Lead Electrodes 1.5 Mm, Spaces 0.5 Mm. Should Be Available In 28-Cm Length And 40-Cm Length. A) Linear Connector B) Lead Resistance: <100 Ohms C) Available In 28 Cm And 40 Cm D) Diameter: 1.27 Mm E) Distance From Tip Of Lead To First Electrode: 1.5 Mm F) Shape: Cylindrical G) Length Of Surface Electrode: 1.5 Mm H) Spacing Between Electrodes 1.5 Mm I) Spacing Between Electrodes 0.5 Mm , 5)Stretcheable Coil Dbs (Deep Brain Stimulation) Extension Dbs Stretch-Coiltm Lead Extension And Accessories To Connect Neurostimulator To Dbs Lead. A) The Extension Has Four Connectors On The Distal End And Eight Connectors On The Proximal End. The In-Line Distal End Connects To A Lead. The Proximal End Connects To A Neurostimulator. (Should Be Compatible To Earlier Mentioned Dbs Parts) B) Low Profile Connector , Lock To Prevent Migration Of Deep Brain Stimulation Leads When The Stylet Is Taken Off (Stimulator Lock) , Implantable Phrenic Nerve Stimulator System (Quote Price For Battery If It Comes With The System) , Implantable Programmable, Rechargeable Battery Compatible With The Phrenic Nerve Stimulator , Implantable Programmable, Non-Rechargeable Battery Compatible With The Phrenic Nerve Stimulator , Implantable Phernic Nerve Stimulator With Radiofrequency Receiver (Without Implantable Battery) , Implantable Diaphragm Pacing System (Fda Approved) , Implantable Hypoglossal Nerve Stimulator For Obstructive Sleep Apnea , Implantable Telemetry Device For Intracranial Pressure Monitoring. It Should Be Capable Of Sending Pressure Readings For More Than 30 Days. Should Be Fda Or Similar Agency Approved. , Vagal Nerve Stimulator For Intractable Epilepsy. All Material For Implantation And Required Training Or Certification, If Any Should Be Provided For 2 Surgeons. , Cusa (Ultrasonic Dissector) Tips : Quote For Cusa Tips Of Various Sizes.It Should Be Compatible With Existing Cusa (25 Khz Ultrasonic Bone Removal Device, Model: Sonopet, Make : Stryker) Available In Neurosurgery Ot. If Not Compatible With This Machine, You Must Provide The Machine On Loan Basis. Quote A Uniform Rate For A Tip If Possible.We Will Inform The Size Of The Tip At The Time Of Placing Order. , Cusa (Ultrasonic Dissector) Tips : Quote For Cusa Tips Of Various Sizes.It Should Be Compatible With Existing Cusa (34 Khz Ultrasonic Bone Removal Device, Model: Sonopet, Make : Stryker) Available In Neurosurgery Ot.If Not Compatible With This Machine, You Must Provide The Machine On Loan Basis.Quote A Uniform Rate For A Tip If Possible.We Will Inform The Size Of The Tip At The Time Of Placing Order. , Cusa (Ultrasonic Dissector) Bone Removing Tips : Quote For Cusa Tips Of Various Sizes.It Should Be Compatible With Existing Cusa (Ultrasonic Bone Removal Device, Model: Sonopet, Make : Stryker) Available In Neurosurgery Ot. , Ultrasonic Dissector Tubings : Quote For Disposable Cusa Tubingof Various Sizes.It Should Be Compatible With Existing Cusa (Ultrasonic Bone Removal Device, Model: Sonopet, Make : Stryker) Available In Neurosurgery Ot. , Drill Bits : Quote For Round Fluted Burs Of Various Sizes, Round Diamond Burs Of Various Sizes.Should Be Caompatible With Long And Short Hand Pieces Of Medronic Neuro Drill Available In Neurosurgery Ot.Quote Separate Prices For Individual Types , Drill Bits : Quote For Round Fluted Burs Of Various Sizes, Round Diamond Burs Of Various Sizes.Should Be Caompatible With Long And Short Hand Pieces Of Karl Storz Endoscopic Drill Available In Neurosurgery Ot.Quote Separate Prices For Individual Types , Toner (Original Manufacturers ) For Canon Laser Printer (Canon Imageclass Mf-4820D Monochrome Multifunction Laser ) Which Is Compatible With The Laser Printers In Dept Of Neurosurgery. (Please Confirm With Dept Before Quoting) , Toner (Original Manufacturers ) For Lexmark Laser Printer (Lexmark Multifunction Laser ) Which Is Compatible With The Laser Printers In Dept Of Neurosurgery. (Please Confirm With Dept Before Quoting) , Toner (Original Manufacturers ) For Brother Laser Printer ( Model Hl - 22 ) Which Is Compatible With The Laser Printers In Dept Of Neurosurgery. (Please Confirm With Dept Before Quoting) , Titanium Clip That Fixes Onto The Diploe Of The Bone Flap Using A Driver. The Clip Should Be Able To Take A 1.5 Mm Self Tapping Screw To Attach To The Rest Of The Skull To Allow Rigid Fixation Using Three Such Clips. , Absorbable Cranial Fixation System,Length Around 10Mm , Microdoppler Probe (Single Use, Disposable) 8 Mhz 2 Mm Tip For Intraoperative, Endonasal Use Compatible With Mizhuo Machine Available In Our Theater. , Microdoppler Probe (Single Use, Disposable) 20 Mhz 0.8 Mm Tip For Intraoperative Use Compatible With Mizhuo Machine Available In Our Theater. , Uniportal Endoscopic Carpal Tunnel Release Set (Disposable Single Use). Should Have Blades (Standard And Slimline) Assembly. Disposable Blade Assembly Should Feature A Retractable Blade That Rises Straight Up Without Curving Outward. Blade Assembly Should Click- Lock On To The Front Of The Pistol-Grip Hand Piece”. Should Have Blade (Standard And Slim) Assembly, Three Sizes Hamate Finders, Synovial Elevators. Must Provide Endoscope On Loan Basis On A 48 Hour Notice Period Before Scheduled Day Of Surgery If Endoscope Is Not Available/Functioningat Jipmer , Reflective Sphere Suitable For Neuronavigation (Stealth S7, Medtronic, "Glions") , Disposable Head Pins With Radiolucent Base Which Will Fit Into Radiolucent Head Holders Like That Of Doro And Medtronic , Non Consumables ( Items Costing Upto Rs.2,00,000/- Only) , Twist Hand Drill : Hand Held Twist Drill Set With Chuck, Drill Bits Of Various Sizes [10 Nos.] , Brain Cannula [Ventriculostomy Cannula] : Opening In The Tip, With Obturator [Stylet] , Leyla Detachable Retractors Holding Rod With Coupling Head( For Fixing Flexible Arms) With Ball And Socket Joint (For Fixing With The Ot Table Side Railings)-To Be Compatible With Jipmer Neurosurgery Ot Table , Leyla Flexible Arms : Flexible Arms Compatible With Both Mayfield And Sugita Head Frame Systems. Must Be Stable Once Locked And Flexible In All Three Dimensions Once Unlocked.This Feature Will Be Tested During Demo And If The Quality Is Not Satisfactory Sample Will Be Rejected , Micro Suction Regulator : Should Be Attached With Suction Tube And To Be Controlled By The Surgeon , Silicone Pediatric Head Holder : Pediatric Silicone Head Fixation System For Use With Doro System And Integra System , Air Bed (Air Mattress) To Prevent And Treat Bed Sores. High Quality With Cpr Compatible Deflation Valve, Multibarelled Type.Each Barrel Should Be Detached Individually(Each Barrel Should Be Replaceable Separately) We Will Reject Non -Barrel Type , Artery Forceps [Dandy’ Artery Forceps Which Have A Right Angle Curve Are Preferred] , Fish Hooks With Spring To Retract Scalp Flap During Craniotomy , Bipolar Forceps Bayoneted (Standard Tip Non Stick, Compatible With Excell Machine Along With Cable (Demo Required)Working Lengthless 10 Cm , Tip 0.5Mm , Bipolar Forceps Bayoneted (Standard Tip Non Stick, Compatible With Excell Machine Along With Cable (Demo Required)Working Lengthmore Than 10 Cm , Tip 0.5Mm , Bipolar Forceps Bayoneted (Standard Tip Non Stick, Compatible With Excell Machine Along With Cable (Demo Required)Working Lengthless 10 Cm , Tip0.7Mm , Bipolar Forceps Bayoneted (Standard Tip Non Stick, Compatible With Excell Machine Along With Cable (Demo Required)Working Lengthmore Than 10 Cm , Tip 0.7Mm , Bipolar Forceps Bayoneted (Concorde Tip Up, Non Stick, Compatible With Excell Machine Along With Cable (Demo Required)Working Lengthless 10 Cm , Tip 0.7Mm , Bipolar Forceps Bayoneted (Concorde Tip Down, Non Stick, Compatible With Excell Machine Along With Cable (Demo Required)Working Lengthless 10 Cm , Tip 0.7Mm , Yasargil Type Spring Rebound Ceramic Covered Tip Bipolar Cum Dissecting Forceps Working Length Around 8 Cm , Yasargil Type Spring Rebound Ceramic Covered Tip Bipolar Cum Dissecting Forceps Working Length Around 12 Cm , Suitable Tray For Storage And Sterilisation For All The Above Bipolar Forceps With Silicon Cushion Mat , Bipolar Forceps Bayoneted (Standard Tip Non Stick, Compatible Withmallis Machine Along With Cable (Demo Required)Working Lengthless 10 Cm , Tip 0.5Mm , Bipolar Forceps Bayoneted (Standard Tip Non Stick, Compatible With Mallis Machine Along With Cable (Demo Required)Working Lengthmore Than 10 Cm , Tip 0.5Mm , Bipolar Forceps Bayoneted (Standard Tip Non Stick, Compatible With Mallis Machine Along With Cable (Demo Required)Working Lengthless 10 Cm , Tip0.7Mm , Bipolar Forceps Bayoneted (Standard Tip Non Stick, Compatible With Mallis Machine Along With Cable (Demo Required)Working Lengthmore Than 10 Cm , Tip 0.7Mm , Bipolar Forceps Bayoneted (Concorde Tip Up, Non Stick, Compatible With Mallis Machine Along With Cable (Demo Required)Working Lengthless 10 Cm , Tip 0.7Mm , Bipolar Forceps Bayoneted (Concorde Tip Down, Non Stick, Compatible With Mallis Machine Along With Cable (Demo Required)Working Lengthless 10 Cm , Tip 0.7Mm , Suitable Tray For Storage And Sterilisation For All The Above Bipolar Forceps With Silicon Cushion Mat , Bipolar Forceps Bayoneted (Standard Tip Non Stick, Compatible With L&T Machine Along With Cable (Demo Required)Working Lengthless 10 Cm , Tip 0.5Mm , Bipolar Forceps Bayoneted (Standard Tip Non Stick, Compatible With L&T Machine Along With Cable (Demo Required)Working Lengthmore Than 10 Cm , Tip 0.5Mm , Bipolar Forceps Bayoneted (Standard Tip Non Stick, Compatible With L&Tmachine Along With Cable (Demo Required)Working Lengthless 10 Cm , Tip0.7Mm , Bipolar Forceps Bayoneted (Standard Tip Non Stick, Compatible With L&Tmachine Along With Cable (Demo Required)Working Lengthmore Than 10 Cm , Tip 0.7Mm , Bipolar Forceps Bayoneted (Concorde Tip Up, Non Stick, Compatible With L&T Machine Along With Cable (Demo Required)Working Lengthless 10 Cm , Tip 0.7Mm , Bipolar Forceps Bayoneted (Concorde Tip Down, Non Stick, Compatible With L&T Machine Along With Cable (Demo Required)Working Lengthless 10 Cm , Tip 0.7Mm , Karlin Cervical Curette. Black Rectangular Handle With Bayyonetted Design. 241 Mm Long. Medium Size , Forward Angle. Exact Size Will Be Mentioned In Purchase Order. Quote One Price For All Sizes. , Suitable Tray For Storage And Sterilisation For All The Above Bipolar Forceps With Silicon Cushion Mat , Friedman Micro Ronguer. Around 15 Cm Long Tip 1.5 Mm Straight , Friedman Micro Ronguer. Around 15 Cm Long Tip 1.5 Mm Curved , Micro Rongeur K-Bayonet, 180Mm (70Mm Working Length), Curved Tip (Kamiyama K-700) Please See Example At This Link: Https://Www.Takayamamicro.Com/Microsurgical-Instruments/Kamiyama-Micro-Rongeur-K-Bayonet-180Mm-70Mm-Wl-Slight-Curve-Tip , Micro Rongeur K-Bayonet, 200Mm (90Mm Working Length), Straight Tip Pin: Kt-701 Kamiyama - Tsuboi Micro Rongeur Has Fine Nose Shape. , Micro Rongeur K-Bayonet, 200Mm (90Mm Working Length), Slightly Curved Tip Pin: Kt-702 Kamiyama - Tsuboi Micro Rongeur Has Fine Nose Shape. , Microforceps K-Bayonet, 180Mm (70Mm Working Length) 45 Degree, 1.5Mm Tip / Pin: K-8220 , Lempert Ronguer 190 Mm(Quote Same Price For Straight And Curved. The Shape Will Be Mentioned In Purchase Order , The Sano Multi Angle Clip Applier For Applying Slimline Sugita Clips . It Should Provide Flexibility In Clip Positioningwith Optimal Visibility Of The Operative Site. The Jointed Shaft And Apair Of Sockets, Housed In The Jaws Of The Applier, Should Allow The Clip To Be Held Through An Arc Of 320°. Adjusting Key Should Be Provided , Bipolar Coagulation Forceps And Tips, Monopolar Tips And Corresponding Cables Compatible With The Karl Storz Neuro-Endoscope System. (Demo Required) , High-End Room Air Purifier Woriking On The Basis Of Forced Air Through High Efficiency Particulate (Hepa) Filter And Activated Carbon Filter To Absorb Pollutants And Volatile Organic Compounds. Clean Air Delivery Rate (Cadr) Should Be 300 M3 Per Hour Or Better. Actual Measurement Of Particulate Pollutants Should Be Displayed. There Should Be Wifi Connectivity To Android Or Ios Devices To Send Information On Air Qualtiy.Ion Cluster Generation. For Icu Or Rooms , Ultrasonic Cleaning Machine For Delicate Microsurgical Instruments. 3 Liter Capacity Or Better. Should Fit Multiple Bayonetted Forceps And Aneurysm Clip Appliers (Atleast Five) Of Size Of 20 Cm Each. , Hair Clipping Machine That Can Be Sterilized Or Capable Of Using Sterile Disposable (Or Resterilisable) Blade Head. The System Should Be Chargeable And Usable Without Cord. Should Be Fda Approved. Handle Should Be Water Proof And Can Be Disinfected. Should Be Capable Of Atleast 40 Minutes Of Use After Charging. (Please Quote For 100 Clipper Heads Along With Machine). Should Be Able To Remove Scalp Hair Easily. , Upper Air Ultraviolet-C Disinfection System (For Icus And Operation Theaters). Shortwave Uv Radiation Peak At Or Around 253.7 Nm (Uv-C)(200-260 Nm Range) Louvres And Reflector Control The Distribution Of Uv-C At The Device Level And Above, Where People Are Not Usually Present, Surface Mountable On False Ceilings Should Comply With Iec 62471 Standard For Photobiological Safety. , Bayonet Dissecting Forceps Working Length Less Than 10Cm Tip 0.5Mm , Bayonet Dissecting Forceps Working Length Less Than 10Cm Tip 0.7Mm , Bayonet Dissecting Forceps Working Length More Than 10Cm Tip 0.5Mm , Bayonet Dissecting Forceps Working Length More Than 10Cm Tip 0.7Mm , Micro Needle Holder,Titanium, Diamond Dusted Jaw, 15Cm Straight , Micro Scissors For Microvascular Anastomosis, Round Handle, Straight Tip, Approximately 145Mm/5 ¾” Length, Titanium Made, Non Glair - Non Reflecting Surface. , Micro Dissecting Scissors For Microvascular Anastomosis, Round Handle, Curved Tip, Approximately 145 Mm/5 ¾” Length, Titanium Made, Non Glair - Non Reflecting Surface. , Micro Forceps For Microvascular Anastomosis, Jeweller Type 0.15Mm Tip, Approximately 110 Mm (4 -3/8”) Length, Titanium Made, Non Glair - Non Reflecting Surface. , Suture Tying Forceps For Microvascular Anastomosis, Curved With Plateau 0.3Mm Tip, Approximately 135 Mm/5-¼” Length, Titanium Made, Non Glair - Non Reflecting Surface. , Biemer – Muller Approximators For Microvascular Anastomosis, Straight, Jaw Opening 5 Mm, Jaw Length 9 Mm, Closing Force 25G-30G, Titanium Made, Non Glair - Non Reflecting Surface. , Biemer Applying Forceps For Microvascular Anastomosis, Without Catch, Approximately 140Mm/ 5-½” Length, Titanium Made, Non Glair - Non Reflecting Surface. , Biemer Vessel Clip For Microvascular Anastomosis, Jaw Opening 5Mm, Jaw Length 9Mm, Closing Force 20G-25G, Titanium Made, Non Glair - Non Reflecting Surface. , Reill Micro Needle Holder For Microvascular Anastomosis,Without Catch, Curved Tip, Approximately 150Mm/6” Length, Titanium Made, Non Glair - Non Reflecting Surface. , Ima Heparin Cannula For Microvascular Anastomosis, Malleable, 1.5Mm Tip Diameter, Titanium/Stainless Steel , Vessel Dilating Forceps For Microvascular Anastomosis, Angled, Approximately 10Cm Length, Tip Diameter 0.2Mm, Titanium Made, Non Glair - Non Reflecting Surface. , Wired Coaxial Ophtalmoscope Fixable On The The Wall With Coil Loop Wiring To Allow Upto 1.5 Meters Of Extension , Interferential Therapy And Tens :-Medium Frequency : 2 Khz & 4 Khz, Base Amf : 1 - 150 Hz, Spectrum Amf : 0 - 150 Hz, Spectrum Programmes : Linear, Trapezoidal, Non Linear.Spectrum Time : 6 Sec & 12 Sec.Therapy Mode : 4 Pole Inerferential Therapy(Static), 4 Pole Vector Interferential Therapy (Dynamic).Treatment Time : 15 Minutes Pre-Settable (Can Be Set Between 1 - 99 Mts.).Intensity : 0 -100 Ma Continuously Variable (I Ma Steps).Balance Control : To Equalise Both The Channel Currents.Output Display: Lcd Display Will Show The Real Patient Current Continuously For Ch 1 & Ch 2.Tens Frequency : 1 To 150 Hz.Russian Current : 2500 Hz Sine Wave.Tens :- Output Current : 0 To 60 Ma, Output Voltage : 0 To 100V (Peak To Peak), Frequency : 1 To 200Hz, Pulse Width : 75 To 360?S, Output Waveform :Symmetric, Treatment Time : 5 - 20 Minutes, Alarm : The Buzzer Alarms When The Intensity Control Is Not At Zero.Types Of Tens : 1. Traditional Tens (Hi Tens, Normal Tens), 2. Acupuncture Tens (Lo Tens, Acutens), 3. Brief Intense Tens, 4. Burst Mode Tens, 5. Modulation Mode Tens. Two Years Warranty , Ultrasound :Maximum Output : 2.5 Watts/Sq.Cm, Operating Frequency : 1 Mhz & 3 Mhz, Mode Of Operation : Continuous Mode & Pulsed Mode, Pulse Ratios : 1:1, 1:4, 1:7 & 1:10, Treatment Time : 0 - 99 Minutes,Alarm : The Buzzer Alarms When The Treatment Time Counts Down To Zero,Display : Led.Two Years Warranty. , Transcutaneous Electrical Nerve Stimulator (Tens) :Treatment Mode : Faradic,Surged Faradic, Galvanic & Interrupted Galvanic.Faradic : Frequency50 Hzand Pulse Width0.7 Ms.Surged Faradic: Frequency 50 Hz And Surged Duration 1 Sec - 6 Sec (Continuously Adjustable). Interupted Galvanic :Frequency 1 Hz, Duration 30Ms - 300 Ms (Continuously Adjustable).Diagnostic Option : Should Be Able To Do Sd Curve.Two Years Warranty. , Perforated Autoclave Tray With Lid And Locking System, Appropriate Size To Accommodate All Above Mentioned Instruments, With Silicone Finger Mat And Instrumentholders , Stainless Steel/Equivalent, Compatible With Autoclaving. , Sugita Interchangeable Suction Tube Set (Please Do Not Exceed Rs 1,00,000) Balanced Handpiece (Flat Teardrop Suction Handle With Safety Coupling ) Which Can Be Kept Between Thumb And Forefinger Space For A Attaching A Range Of Suction Cannulasbalanced Handpiece (Flat Teardrop Suction Handle With Safety Couplingcannulas Are Of The Following Sizes (3 To 12 French, Each In Following Lengths - Short: 7.6 Cm Medium: 9.5 Cm Long: 11.4 Cm Extra Long: 13.3 Cm. Also Multihole Tube Type Each 5, 7 And 9 French (All Suction Cannulas [43 Numbers] Should Preferably Come In Its Own Case). The Suction Cannulas Have To Be Pre-Bent 30 Degrees, Malleable And Rotatable And Ability To Change Tube Without Discarding Hand Piece. (One Set Should Contain All The Above Mentioned Items) , Kerrison Bone Punch 1Mm 90 Degree Up Cut (Long) , Kerrison Bone Punch 1Mm 90 Degree Down Cut (Long) , Kerrison Bone Punch 2Mm 90 Degree Forward Up Cut , Kerrison Bone Punch 3Mm 90 Degree Forward Up Cut , Kerrison Bone Punch 3Mm 130 Degree Forward Up Cut , Kerrison Bone Punch 4Mm 130 Degree Forward Up Cut , Rotatable Kerrison Bone Punch (90 Degree)Assembly (Billy Or Equivalent) With Two Punches 1 Mm And 2 Mm Each. (1 Mm - 1Set 2Mm - 1 Set ) , Suction Cannula Frazier Type Working Length 8Cm 3F Size , Suction Cannula Frazier Type Working Length 8Cm 6F Size , Suction Cannula Frazier Type Working Length 8Cm 9F Size , Suction Cannula Frazier Type Working Length 12Cm 3F Size , Suction Cannula Frazier Type Working Length 12Cm 6F Size , Suction Cannula Frazier Type Working Length 12Cm 9F Size , Suitable Tray For Storage And Sterilisation For All The Above Bipolar Forceps With Silicon Cushion Mat , Suction Cannula Fergusson Type ,Conical Tube,Atraumatic Rounded Tip,Tear Drop Shaped Suction Interuptor,Working Length 8Cm 3F Size , Suction Cannula Fergusson Type ,Conical Tube,Atraumatic Rounded Tip,Tear Drop Shaped Suction Interuptor,Working Length 8Cm 6F Size , Suction Cannula Fergusson Type ,Conical Tube,Atraumatic Rounded Tip,Tear Drop Shaped Suction Interuptor,Working Length 8Cm 9F Size , Suction Cannula Fergusson Type ,Conical Tube,Atraumatic Rounded Tip,Tear Drop Shaped Suction Interuptor,Working Length 12Cm 3F Size , Suction Cannula Fergusson Type ,Conical Tube,Atraumatic Rounded Tip,Tear Drop Shaped Suction Interuptor,Working Length 12Cm 6F Size , Suction Cannula Fergusson Type ,Conical Tube,Atraumatic Rounded Tip,Tear Drop Shaped Suction Interuptor,Working Length 12Cm 9F Size , Suitable Tray For Storage And Sterilisation For All The Above Bipolar Forceps With Silicon Cushion Mat , Rhoton Round Microdissector 2Mm Tip Titanium , Rhoton Round Microdissector 4Mm Tip Titanium , Rhoton Spatula Microdissector 2Mm Tip Titanium , Rhoton Spatula Microdissector 4Mm Tip Titanium , Rhoton Ball Microdissector 90 Degree Angled Titanium , Penfield Round Handle Single Tip Flat Curved Dissector 2Mm Tip,Stainless Steel , Penfield Round Handle Single Tip Flat Curved Dissector 5Mm Tip,Stainless Steel , Suitable Tray For Storage And Sterilisation For All The Above Bipolar Forceps With Silicon Cushion Mat , Right Angle Clamp (Fine Tip) , Raney Clip Applicator , Macdonald Dissector , Dural Guide , Howarth Periosteal Elevator , Artery Forceps, Curved,Mosquito , Artery Forceps, Straight, Mosquito , Microball Probes, 90 Degree & 45 Degree (One Each) , Nerve Root Retractor , Micro Disc Punches, Non- Ceramic Coated, Straight- 3 Nos And Angled- 1 Nos , Regular Disc Punches, Non- Ceramic Coated, Straight - 3 Nos And Angled- 1 Nos , Micro Disc Punches, Ceramic Coated, Straight - 4 Nos , Regular Disc Punches, Ceramic Coated, Straight - 3 Nos& Angled- 1 Nos , Vertebral Spreader Which Expands From Within The Disc Space In Anterior Cervical Discectomy And Fusion Procedure , Vertebral Spreader Which Expands Using Two Pins That Penetrates Vertebral Boddies In Anterior Cervical Discectomy And Fusion Procedure , Luer - Stille Bone Rongeur, 225Mm / 9" , Frykhon Bone Rongeur, 240Mm / 9-1/2" , Mayfield Bone Rongeur, 175Mm / 7" , Echlin Bone Rongeur, 230Mm / 9" , Gigli Saw Holder , Freer Periosteal Elevator, 185Mm, 7-1/4", Sharp & Blunt (One Each) , Caspar Bone Curettes, 3Mm Tip ,5Mm Tip, Straight & Angled (One Each) , Jansen Self Retaining Retractor, 100Mm, 4" , Weitlander Self Retaining Retractor, 165Mm, 6-1/2" , Adson Self Retaining Retractor, 320Mm, 12-3/4" , Beckman Eaton Self Retaining Retractor, 320Mm, 12- 3/4" , Micro Jewellers Dissecting Forceps,Flat Handle.Tip 0.5-1Mm,Around 15 Length.Titanium , Micro Suture Tying Forceps With Round Handle And Diamond Dusted Plateau At The Tips, Around 15Cm Length, 1-2Mm Tip,Titanium , Micro Forceps With Diamond Dust Coating At Tip And Round Handle, Around 15 Cm Length,Straight 1-2Mm Tip ,Titanium, , Micro Needle Holder,Titanium Around 15 Cm Length With Diamond Dusted Holding Surface Straight Tip 1-2Mm , Micro Needle Holder,Titanium Around 15 Cm Length With Diamond Dusted Holding Surfacecurved Tip 1-2Mm , Micro Forceps With Diamond Dust Coating At Tip And Round Handle, Around 15 Cm Length,Curved 1-2 Mm Tip ,Titanium, , Suitable Tray For Storage And Sterilisation Of The Above 6 Titanium Microinstruments With Silicone Protective Spike Cushions , Yasargil Microscissors Stainless Steel Or High Quality Alloy,Non Glare Matt Finish Surface,Bayonetted ,Working Lenth 8Cm Blade 14Mm Opening 4Mm Staight Tip , Yasargil Microscissors Stainless Steel Or High Quality Alloy,Non Glare Matt Finish Surface,Bayonetted ,Working Lenth 8Cm Blade 14Mm Opening 4Mm Upcurved Tip , Yasargil Microscissors Stainless Steel Or High Quality Alloy,Non Glare Matt Finish Surface,Bayonetted ,Working Lenth 10Cm Blade 14Mm Opening 4Mm Staight Tip , Yasargil Microscissors Stainless Steel Or High Quality Alloy,Non Glare Matt Finish Surface,Bayonetted ,Working Lenth 10Cm Blade 14Mm Opening 4Mm Upcurved Tip , Yasargil Or Vannas Microscissors Stainless Steel Or High Quality Alloy,Non Glare Matt Finish Surface,Straight Flat Handle ,Total Lenth 10Cm Blade 5-7Mm Opening 3-5Mm Staight Tip , Yasargil Or Vannas Microscissors Stainless Steel Or High Quality Alloy,Non Glare Matt Finish Surface,Straight Flat Handle ,Total Lenth 10Cm Blade 5-7Mm Opening 3-5Mm Upcurved Tip , Yasargil Or Vannas Microscissors Stainless Steel Or High Quality Alloy,Non Glare Matt Finish Surface,Straight Flat Handle ,Total Lenth 15Cm Blade 5-7Mm Opening 3-5Mm Staight Tip , Yasargil Or Vannas Microscissors Stainless Steel Or High Quality Alloy,Non Glare Matt Finish Surface,Straight Flat Handle ,Total Lenth 15Cm Blade 5-7Mm Opening 3-5Mm Upcurved Tip , Yasargil Microscissors Stainless Steel Or High Quality Alloy,Non Glare Matt Finish Surface,Straight Flat Handle ,Total Lenth 15Cm Blade 5-7Mm Opening 3-5Mm Staight Dissecting Tip , Yasargil Microscissors Stainless Steel Or High Quality Alloy,Non Glare Matt Finish Surface,Straight Flat Handle ,Total Lenth 15Cm Blade 5-7Mm Opening 3-5Mm Upcurved Dissecting Tip , Yasargil Microscissors Stainless Steel Or High Quality Alloy,Non Glare Matt Finish Surface,Straight Flat Handle ,Total Lenth 15Cm Blade 5-7Mm Opening 3-5Mm Staight Serrated Cutting(Super Cut) Surface Tip , Suitable Tray For Storage And Sterilisation For All The Above Bipolar Forceps With Silicon Cushion Mat , Diamond Knife Wedge Balde, Length Around 20Cm , Hardy Pituitary Curettes, 4Mm, Forward Angled, Straight , Nicola Malleable Pituitary Curette , Caspar 360 Degree Rotatable Pituitary Scissors , Metzenbaum Scissors, 152 Cm , Microserrations At Cutting Edge, Slim, Black Handle , Metzenbaum Scissors, Meddium Size, 115 Mm, Straight , Metzenbaum Scissors, Meddium Size, 115 Mm Curved , Steven Tenotomy Scissors 15 Cm With Black Coating , Micro-Adsons Toothed Forceps, 150Mm, 6" , Standard Tissue Forceps, 145Mm, 5-3/4" , Rotatable Kerrison Bone Punch Assembly (Billy Or Equivalent) With Two Punches 1 Mm And 2 Mm Each. , Micro Kerrison Convertible Ejector Ronguer With Thin Foot Plate. Quote Uniform Price For All Sizes. Sizes Will Be Mentioned In Purchase Order. , Detachable Kerrison Which Allows Rapid Cleaning Of Debris With Ejector Mechanism. Quote Uniform Price For All Sizes. , Hegar-Mayo Needle Holder, 150Mm, 6", Tungsten Carbide Tipe , Shunt Tunneller, Adult , Shunt Tunneller, Peadiatric , Peritoneal Trocar , Friedman Micro Ronguer. 140 Mm Long. (Quote Same Price For Straight And Curved. The Shape Will Be Mentioned In Purchase Order , Lembert Ronguer 190 Mm(Quote Same Price For Straight And Curved. The Shape Will Be Mentioned In Purchase Order , The Sugita Aneurysm Clip Case: Should Be A Modular System Comprised Of Four Individual Clip Cases, Housed In An Instrument Bin, Locked In Place With One All-Encompassing Lid. The Clip Case Should Allow For Storage Of Up To 120 Individual Clips As Well As 10 Appliers (Including 2 Keyhole Appliers). The Clips Are Organized By Clip Type, Allowing For Quick Access To The Necessary Pattern. A List Of Appliers, By Type, Should Laser Etched Inside The Lid For Ease Of Reference. Spring Handled Appliers Should Be Held In Place With Silicone Brackets. Keyhole Appliers Are Stored Under The Clip Cases. Each Individual Clip Case Can Be Used As A Stand Alone Storage And Sterilization Container. , The Sano Multi Angle Clip Applier For Applying Slimline Sugita Clips . It Should Provide Flexibility In Clip Positioningwith Optimal Visibility Of The Operative Site. The Jointed Shaft And Apair Of Sockets, Housed In The Jaws Of The Applier, Should Allow The Clip To Be Held Through An Arc Of 320°. Adjusting Key Should Be Provided , Nano Scissors, Red, 15Cm Curved, 2.5Cm Wl , Nano Needle Holder, Blue, Diamond Dusted Jaw, 15Cm Straight, 2.5Cm Wl , Nerve Root Suction Retractor , Liga Clip Applicator. , Fukushima Key Hole Sugita Aneurysm Clip Applicator With Very Thin Profile And Milled Grip To Secure Large And Mini Clips , Perneczky Type Aneurysm Clip Applying Forceps , Lawton Deep Cavernous Malformation Set (Should Not Exceed 1 Lakh) Should Contain Straight, 30 And 45 Degree Angled And Reverse Angled 1 Mm Thick Dissectors , Spurling Black Coated Intervertebral Disc Ronguers With Semidetachable Shaft With Ceramic Coating , Olivecrona Dura Forceps 2X3 Fine Teeth . 15 Cm , Osteotome With 8 Mm Edge,4 Mm Edge (4Mm -2 Nos 8Mm - 2Nos) , Instrumentation For Cranioplasty Using Micro Plates And Screws Includes The Following. 1)Screw Driver Handle -1No, 2) Screw Driver Shaft-2No, 3)Plate Bender-2Nos, 4)Plate Cutter-1No, 5) Plate Holding Grasping Forcep-1No. , Instrumentation For Flap Fixation Clamp System Includes The Following.1) Clamp Appying Forceps -1No,2) Clamp Holding Forceps-1No, 3) Rod Cutter-1Nos,4)Clamp Removing Forceps-1No, 5) Instrumentation Tray For Holding The Instruments , Resistance Band (Thera Band With Different Levels Of Resistance With Colour Code) : Colour Of Bands : Yellow, Red, Green, Blue, Black And Silver.Length Of Bands : - 1.5 Mtr Each. , Gardner - Wells Skull Tongs Along With Traction Pulley And 10Kg Weights (1Kg - 6 Nos., 2Kg - 2 Numbers) The Skull Tongs Should Have Spring Loaded Pins. , Mesh Bender For Easy Bending Of Dynamic Titanium Meshes That Can Be Contoured. , Titanium Mesh Cutter , Patient Positioning Silicone/Deformable Polimer Gel Device (Sacral Protector-Adult) , Patient Positioning Silicone/Deformable Polimer Gel Device (Sacral Protector-Pediatric) , Patient Positioning Silicone/Deformable Polimer Gel Device (Flat Arm Board Pad-Adult) , Patient Positioning Silicone/Deformable Polimer Gel Device (Flat Arm Board Pad-Peadiatric) , Patient Positioning Silicone Gel/Deformable Polimer Device (Heel Support Pad - Adult) , Patient Positioning Silicone Gel/Deformable Polimer Device (Heel Support Pad - Pediatric) , Patient Positioning Silicone/Deformable Polimer Gel Device(Dome - Flat Bottom Chest Roll - Pediatric) , Patient Positioning Silicone/Deformable Polimer Gel Device (Dome - Flat Bottom Chest Roll - Adult) , Implant Module With Three Lift Out Inlays For Storage Of Plates, Screwdrivers And Drill Bits Capable Of Storing Titianium Mesh Up To 90 X 90 Mm Under The Screw Bay. Include A Screw Driver. , Patient Warmer Based On Convective Forced Air Warming Technique With Ten Adult Blankets And Ten Pediatric Blankets To Be Supplied. Filter Change Indicator Is Desirable.Two Years Warranty Is Essential. , Percutaneous, Sterile, Ready To Use Tracheostomy Set. , Balloon Kyphoplasty Set With Kyphoplasy Cement In Sterile Ready To Use Package. Should Have A Pressure Indicating Syringe With Digital Display. , Intracranial Pressure Monitor (Supply One Compatible Parenchymal Or Subdural Or Ventricular Consumable Item) , Chlorhexidine Slow Release Disc Which Can Be Placed At The Site Of Indwelling Vascular Catheters. Should Release The Agent Over Seven Days. , Polytetrafluoroethylene Patch 0.3 Mm Thickness Suitable For Carotid Endarterectomy (7X5 Cm) , Absorbable Cranial Fixation System Thin Profile (Craniotomy Bone Flap Fixation) Fda Approval Is Desirable, All Necessary Tools For Implantation Should Be Provided On Loan Basis , Cyanoacrylate Microbial Sealants For Skin Preparation Prior To Surgery In A Disposable, Sterile, Single- Use Applicant That Can Cover An Area Of 20 X 20 Cm , Endotracheal And Tracheostomy Cuff Pressure Controller To Continously Monitor Cuff Pressure Within The Ideal Range Of 20-30 Cm Of Water. It Should Have A Pressure Feedback Mechanism To Increase Pressure During Peak Inspiration. Single Use, Disposable, Sterile , Bronchial Hygiene Vibratory Pep Therapy System : Should Benefit Both Pep Therapy And Airway Vibration To Mobilize Pulmonary Secretions And Also In Virtually Spatial Orientaion.Should Allows Inhalation And Exhalation Without Removing From Mouth, To Be Used With Mask Or Mouth Piece Nebulizer.Should Have Pressure Port With Pressure Indicator, Tubing, Mouthpiece, Mask Of Different Sizes.It Should Have Provision For Frequency Adjustment. , Hand Cuff Pressure Gauge And Inflator •Gauge Monitorintra Cuff Pressure Of Endo Tracheal Tubes/ Tracheostomy Tubes Should Have Conveneint, Ergonomic Design •Should Be Able To Inflate Or Deflate Cuff As Per Requirement •Should Form An Adequate Seal And Safe Cuff Pressure •Should Calibrated In Cm Of Water •Should Fitted With Clip Attachment For Storage & Quick Access For Intra Cuff Pressure Monitoring. •Should Have Additional Extension Cord Supplied With The Instrument •Should Have Button To Adjust Pressure ( Reducing Cuff Pressure) •Should Have The Provision In The Bottom Of Instrument For Deflating The Cuff" , Long Screwdriver For Placing The Stereo-Eeg Electrode , Wrench For Placing The Stereo-Eeg Electrode , Clamp For Placing The Stereo-Eeg Electrode , Ruler For The Stereo-Eeg Electrode , Drill (Length Of 200 Mm) For Placing The Stereo-Eeg Electrode , Drill (Length Of 250 Mm) For Placing The Stereo-Eeg Electrode , Stylet With Stopper For Placing The Stereo-Eeg Electrode , Straight Coagulation Electrode 30 Mm Compatible With The Stereo-Eeg Electrode , Dennis Micro Ring Tip Forcep 8 1/4" With 1Mm * 0.5Mm Tip And Counterbalance , Gerald Tissue Forceps- 2*1 Teethed,1.4 Mm Tip, Straight, 7 Inches , Gerald Tissue Forceps- 2*1 Teethed,1..4 Mm Tip, Bayonet, 7 Inches , Control Unit That Will Interface With The Single Use Iso-Thermic Skin Temperature Probe Described In The Consumables Section. It Should Be Compact With The Largest Dimension Not Greater Than 9 Cm. Weight Should Not Be More Than 140 Grams. Supply Five Skin Termperature Probes Also. , Weight Cuff With Velcro Strap. Set Of 1Kg, 2Kg & 3Kg Cuffs (One Set Should Ocntain All The Items) , Rubber Dumbells.Set Of 1Kg, 2Kg & 3Kg Dumbells For Muscle Strengthening , Resistance Band (Thera Band With Different Levels Of Resistance With Colour Code) : Colour Of Bands : Yellow, Red, Green, Blue, Black And Silver.Length Of Bands : - 1.5 Mtr Each. Quote Uniform Rate For All Bands. The Exact Quantity And Type Of Band Will Be Mentioned At The Time Of Order Placement. , Frame Walker (Medium Size) , Foldable Walker For Making The Patient To Walk With Support , Quadripod For Making The Patient To Walk With Minimal Support , Tripod For Making The Patient To Walk With Minimal Support , Spinal Braces (Taylors Brace) : Size: Small, Medium & Large. Quote Uniform Rate For All Sizes. The Actual Requirement Of Sizes Will Be Intimated At The Time Of Order Placement , Hand Dynamometer: Analogue Dial Type Display With Ability To Measure Upto 90 Kg Or Better , Hand Dynamometer: Electronic With Ability To Measure And Display Upto 90 Kg Or Better , Suction Cannula Fukushima Type Working Length 8Cm 3F Size , Suction Cannula Fukushimatype Working Length 8Cm 6F Size , Suction Cannula Fukushimatype Working Length 8Cm 9F Size , Suction Cannula Fukushimatype Working Length 12Cm 3F Size , Suction Cannula Fukushimatype Working Length 12Cm 6F Size , Suction Cannula Fukushimatype Working Length 12Cm 9F Size , Ramanis Spine Retractor With Atleast 4 Sets Of Blades And Hooks , Compact Led Light Source With A Goose Neck Suitable For Use In Icu. Foot Print Should Not Exceed A Maximum Diameter Of 60 Cm , Foramenotomy Kerrison Roungers With Upward Curve-2Mm , Foramenotomy Kerrison Roungers With Upward Curve-3Mm , Super Micro Bone Rongeur Bayonetted Forceps Type-Straight Tip With 90Mm Working Distance , Super Micro Bone Rongeur Bayonetted Forceps Type-Upward Turned Tip With 90Mm Working Distance , Bayonetted Shaft Kerrison Rounger 45 Degrees Upturned 2Mm Tip , Bayonetted Shaft Kerrison Rounger 45 Degrees Upturned 1Mm Tip , Tubular Retractor System For Minimally Invasive Intracranial Hematoma Evacuation , 13.Mm Diameterof Varying Tlength-Should Have An Obturator And Sheath , Suction Irrigation System With Softtube Tip For Use With Neuroendoscope For Intrcranial Hematoma And Intraventricular Hematoma
|