Tender For supply of Mri Simulator , Mr Simulator As Per The Specification Except The Following , Mr-Rt Planning , Additional Workstation , Mr Compatible Pressure Injector With Syringes , Full System Ups , Dry Imager , Iv Stand ( Mr Compatible ) , Patient Trolley ( Mr Compatible ) , Music And Pa System With Speakers , Patient Comfort Kit As Per Spec , Hand Held Metal Detector , Metal Detector Door , Wheel Chair ( Mr Compatible ) , Fire Extinguisher Mr Compatible , Mr Compatible Stethoscope , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) :Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System ( Cup Lock Type ) On The Exterior Side Of Building / Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1 ) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, ( 2 ) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 15.60 Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size ) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size ) . , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S ( Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand ) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made ) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand ) Including Cost Of Scaffolding Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand ) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand ) , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) , Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976 / 2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) , Using Good Quality Anjili Wood / Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili / Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portionpowder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977 / 2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 " X 16" Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978 / 2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979 / 2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm ) , With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980 / 2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C / C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms / Sqm ( Both Side Inclusive ) , Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, , Made Of G.I Sheet Having Galvanizing Of 100 Gms / Sqm ( Both Sides Inclusive ) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns ( Minimum ) , Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams / Sqm, Both Side Inclusive ) Consisting Of Main "T" Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200 Mm Center To Center And Cross "T" Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Space Between Main "T" At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross "T" Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main "T" Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg / Sq. Cm, Bending Strength 100 Kg / Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc ( Noise Reduction Coefficient ) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg / Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately ) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer ( Fittings To Be Paid Separately ) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc ( Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) , 10.16.3 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981 / 2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982 / 2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983 / 2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500 / 31000 / 40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I / C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878 / 2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf / Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf / Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf / Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf / Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf / Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf / Cm2 , Od31984 / 2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized / Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness, Fixed To The Shutter Styles By Means Of Plastic / Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge ( For W.C. And Bathroom Door Shutter ) . , Od31985 / 2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986 / 2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987 / 2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989 / 2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990 / 2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991 / 2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board / Any Other False Ceiling. The Rate Including All Labour Charges , Material Charges Ect Complete. , Od33559 / 2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth ( Bio-Active Fabric Washable Germfree-Suitable For Icu Room ) Curtain System With Maximum Curtain Cloth Height 230Cm ( Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval ) Stitching With Stifiner Tape, Pleats, Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging / Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup , All Leads And Lifts Including All Labour Charges Etc. Complete. ( Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet ) / Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length ( App. Length 1.10M ) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C / C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level , Sealing All Gaps In False Ceiling Due To Hanging Supports , All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560 / 2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Providing, Making And Fixing In Position Partition Walls Over A Wooden Frame Work Of Size 50X50mm With Hard Wood Pinkoda / Violet / Or Equivalent Frame Work At 60Cm Or Nearest As Verticals And Three Numbers Of Horizontals, Spacing As Shown In The Drawing With 10Mm / 12Mm Thick Marine Plywood On Onesides Of The Frame Work For The Fullheight Of Height And Fixing Plywood With Teak Wood Beadings Between Plywood And Wooden Frame With Suitable Junction Joints And Extra Supports If Needed For Joinery Openings.The Plywood Is Fixed To The Frame Work Using Steel Screws Including Finishing The Joints With Joint Filler Etc.To Get Smooth And Even Finished Joints Including Cost And Labour Charges Of All Materials And The Outer Frames Fixing To Concrete / Masonry By Chipping And Providing Tight Plugs, Making Good The Damages, Including Cost Of All Materials Such As All Wooden Members, Plywood On Onesides, Etc. Complete, Wooden Sections Confirming To The Nearest Dimensions Etc.For Fixed Partitions Etc Complete As In The Drawing And As Per Requirement. The Rate Inclusive Of All Material Charge, Labour, Transportation, Scaffolding ( If Needed ) Loading / Unloading At The Work Spaceetc. Complete As Per The Direction Of Engineer In Charge. , Wood Frame For Fixing Lead Glass ( Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard ( Godrej ) For Storage 6Ft Tall 3 Feet Width , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 4 Sq. Mmm , Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25Mm , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5 / 6 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module ( 100Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module ( 200Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module ( 125Mmx125mm ) , Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Extra For Fixing The Louvers / Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep , Supply Of 300 / 305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va / C , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required4 Way ( 8+12 ) - Three Phase Double Cover ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required6 Way ( 8+18 ) - Three Phase Double Cover ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way ( 8+12 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way ( 8 + 18 ) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp / Tp Mcb As Outgoing ( Ip 42 / 43 ) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface / Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Supplying And Fixing Following Rating, Four Pole, ( Three Phaseand Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, "C" Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required100 Amp, 30 Ka 4 Pole , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required125amp, 36Ka , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35 / 36 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required.4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%, , Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etcas Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1 / 2X 70 Sq. Mm ( 38Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 95 Sq. Mm ( 45Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 185 Sq. Mm ( 57Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 240 Sq. Mm ( 62Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm ( 25Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm ( 28Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm ( 28Mm ) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 50 Sq. Mm ( 35Mm ) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required.25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium / Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2 / 3 / 3½ / 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required.10 Sqmm , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens / Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.65 Mm Copper Conductor ( 12 Swg ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required4.00 Mm Copper Conductor ( 8 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm ( 12 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm ( 10 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm ( 8 Swg ) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal / Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall / Parapet / Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required ( For Horizontal Run ) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads40mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection / Terminating With Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg ) , Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16 / 0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W ( Max ) , 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Recess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required ( Philips, Wipro Or Similar Superior Make ) , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes ( Make: M / S Almonard / Crompton / Bajaj Or Equivalent ) , Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Numbering Of Ceiling Fan / Exhaust Fan / Fluorescent Fittings As Required. , Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable ( Size As Per The Requirement Of Ac Manufacturer ) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit ( Powder Coated ) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar / Lg ( Dual Inverter Type ) / Voltas / Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw / Hr With Rotary / Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500 / 450, Led / Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables / Wires ( Havells / Rr Kabel / V-Guard Frls Wires ) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg / Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts / Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges , Supports, Gi Rods , Anchor Bolts , Gi Nuts And Bolts, Pvc / Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof / Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges , Supports, Gi Rods , Anchor Bolts , Gi Nuts And Bolts, Pvc / Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof / Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply And Providing Copper Earth Bus In The Panel Board , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A / 400A, 50 / 55 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Suitable De- Humidifier Units : Extraction At Least 35 Litres / Day, Compresor : Rotary, Air Flow : At Least 220M3 / Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Supply, Installation, Testing And Commissioning ( Sitc ) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu / Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring ( Max 3M From Isolator ) And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out, Suitable For Three Phase 440V Supply Etc Complete As Required , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale. ( 0-200 ) A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp Digital Multifunction Meter To Read V, A.Hz, Pf, Kwh Surge Protection Device ( Type1+2 ) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale. ( 0-200 ) A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp, Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification , Additional Iron Shielding If Any , Mr Compatible Pipe For Medical Gas 12Mm , Mr Compatible Outlet , Mr Compatible Flowmeter With Humidifier , Mr Compatible Wall Mounted Suction Jar , Mr Compatible Probes , Mr Compatible Bed Head Panels For 6 Outlets , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb ( 0-500 ) V Class 1 With 90 Deg Defl. Scale ( 0-200 ) A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200 / 5 A 5 Va Class .5S Cts On / Off Indication Lamp, Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 2 Nos.The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. ( Not Taken For Evaluation ) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall / Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel ( Required For Short Circuit Rating, Temperature Rise And Ip Classification ) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V, A.Hz, Pf, Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link ( Ics =100%Icu= 25Ka ) - 1 Nos %Icu= 25Ka ) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry / Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. ( Not Taken For Evaluation ) , Supply, Installation, Testing And Commissioning ( Sitc ) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu / Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring ( Max 3M From Isolator ) And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out, Suitable For Three Phase 440V Supply Etc Complete As Required. ( Not For Evaluation ) , Small Fov Diffusion Like Focus, Zoomit, Zoom Diffusion ( Not Taken For Evaluation ) , Breast Spectroscopy Like Brease, Grace, Breast Spectro. ( Not Taken For Evaluation ) , Cartilage Assessment Like Cartigram, Mapit, Cartilage Assessment. ( Not Taken For Evaluation ) , Free Breathing Abdominal Imaging Like Ideal / Freezit ( Not Taken For Evaluation ) , Liver Imaging Package With Iron Quantification Like Ideal Iq / Liverlab Etc. ( Not Taken For Evaluation ) , Bone Imaging. ( Not Taken For Evaluation ) , Oncology Support Assembly For Head / Neck, Flex Coils For Neuro, Body & Pelvic Imaging. ( Not Taken For Evaluation )
|