Tender For Electrical And Mechanical Works Atbhagwant Sagar ( Sukta Dam ) District Khandwa Proposed Under Drip Ii.; 1 Stop Log Gate 2 Design, Drawing, Fabrication, Supply, Erection, Testing And Commissioning Of Embedded Parts Consisting Of Sill Beam, Vertical Tracks, Vertical Seal Tracks , Sealing Frame, Guide Tracks / Rails, Wall Plates, Seal Seats, Anchors, Anchor Girders, Yoke Girders, Tie Flats, Trunnion Supports, Rope And Pulley Supports Etc. And Any Required Necessary Item , With All Accessories As Per Relevant Is Code, For All Type Radial Gates / Vertical Lift Fix Wheel Type Sluiceand Canal Gates / Stop Log Gates Including Cost Of All Materials Machinery , Labour, Cutting, Aligning, Anchoring , Welding, Finishing, Cleaning, Tools And Tackles, Applying Two Coat Of Zinc Rich Epoxy Primerto Give Dry Film Thickness Of 70± 5 Microns And Finish Coat ( Two Coats ) Of Solvent Less Coal Tar Epoxy Paint Using Airless Spray To Provide Dry Film Thickness Of 150± 5 Microns Per Coat Thus Total Dryfilm Thickness Of All Coats, Including Primer Coating, Should Not Be Les Than 350 Microns., Includingpacking & Forwarding, Transportation Charges Complete Item, Asper Specificationsand Approved Drawings. ( Embedded Parts Fo 12.67X6.7 Fo 6Nos Opennigencluding Latching Arregement ) 3 Design, Drawing, Fabrication, Supply, Errection, Testing And Commissioning Of Verticallift Fix Wheel Type Sliding Gate / Inter Changeable Stop Log Gates Consisting Of Skin Plate, Stiffeners, Horizontal Girders, Pulley, Pulley Supports, Bracings, Lifting Lug , Bracket, Rubber Seals, Clamps Plates Etc., With All Accessories As Per Relevant For Canal, Sluice Vertical Gates And Spillway Gates Including Cost Of All Materials, Machinery, Labour, Cutting, Bending, Aligning, Anchoring, Welding, Seal Fixing, Tools And Tackles Etc., Finishing, Cleaning, Applying Two Coat Of Zinc Rich Epoxy Primer To Dry Film Thickness Of 70+ 5 Microns And Finish Coat ( Two Coats ) Of Solvent Less Coal Tar Expoxy Paint Using Airless Spray To Provide Dry Film Thickness Of 150+ 5 Microns Per Coat Thus Total Dry Film Thickness Of All Coats, Including Primer Coating, Should Not Be Less Than 350 Microns., Complete As Per Specifications And Approved Drawings Complete, Including Packing & Forwarding, Transportation Charges For Structural Steel Components And Other Materials. 45Ton Size 12.6Mx1.4M ( 4Nos Interchangeble+2Nos Bottom Unit ) 4 Design, Drawing, Fabrication, Supply, Errection And Commissioning Of Trestle Assy / Railing Decking / Trash Rack / Structural Steel Hoist Bridge / Structural Steel Hoist Supporting Structure For Mono Rail / Catwalk Bridge For Connecting Spillway Piers For All Type Of Sluice With Embedded Parts Consisting Of Clumns, Beams, Bracings, Stiffeners, Ties, Chequered Plate Covering, Hand Railing, Ladder Etc., With All Other Accessories For Operating Gates, Other Structure Including Cost Of All Materials, Machinery, Labour, Tools And Tackles, Cutting, Aligning, Anchoring, Welding, Finishing, Cleaning, Applying Two Coats Of Zinc Chromate Red Oxide Primer And Three Coats Of Approved Synthetic \ \ Namel Paingt Etc., Complete As Per Specifications And Approved Drawings, Including Packing & Forwarding, Transportation Charges For Structural Steel Components And Other Materials. 5 Design, Drawing, Fabrication, Supply, Erection, Testing And Commissioning Of Eot Crane Consisting Of Double Girder Box Type Construction, Rail Mounted Endcarriages With Long And Cross Travel Arrangement, Main And Auxiliary Hoists Of Specified Capacity, Rails, Pendant Control, Gear Boxes, Electric Motors, Brakes, Rope Drums, Wire Ropes, Sheaves, End Buffer Stoppers, Pendant Operated Dsl Bus Bars With All Accessories For Main And Auxiliary Hoists For Handling Pumps And Accessories In Pump House Including Cost Of All Materials, Machinery, Labour, Cutting, Aligning, Welding, Finishing, Cleaning, Greasing, Applying Two Coats Of Zinc Chromate Red Oxide Primer And Three Coats Of Synthetic Enamel Paint Etc., Complete As Per Specifications And Approved Drawings With All Lead And Lifts, Including Packing & Forwarding Transportation Charges For Structural Steel Components And Other Materials. ( Eot Crane 30 Tonne Capacity ) 6 Design, Drawing, Fabrication, Supply, Erection, Testing And Commissioning Of Automatic Lifting Beam With All Accessories, Like Automatic Detachlattach System, Hooks / Rollers, Guides, Pins Complete For Handling, Lowering And Lifting Of Stop Logi Emergency Gates Including Cost Of All Materials, Machinery, Tools Ard Tackles, Labour, Cutting, Aligning, Welding, Finishing, Cleaning, Applying One Coat Of Zinc Rich Epoxy Primer And Two Coats Of Cold Applied Coal Tar Epoxy Paint Etc., Complete As Per Specifrcations And Approveddrawings, Including Packing & Forwarding, Transportation Charges For Stuctural Steel Components And Other Materials. ( Per Tonne Weight ) 7 Modernization Of Hoist For Sluice Gate ( Size 2.44Mx1.83M ) 2 Nos 8 Design, Drawing, Fabrication, Supply, Erection , Testing And Commissioning Of Adequate Capacityelectrically Operated Rope Drum Hoist According Torelevant Is Code, Consisting Of Hoist Platform Bridge, Rope Drums, Connecting Shaft, Gear System, Reduction Gear Unit, Electric Motor, Electro Magnetic Brake System, Control Panel, Pulleys, Wirerope, Gate Position Indicator, Limit Switch With In Built Manual Operating System, Etc. Complete, With All Accessories For Operating Gates Includingcost Of All Materials, Machinery, Labour, Cutting, Aligning, Anchoring, Welding, Finishing, Cleaning, Greasing, Oil Filling, Tools And Tackles, Applying Two Coats Of Zinc Chromate Red Oxide Primer And Threecoats Of Approved Synthetic Enamel Paint Etc., Complete As Per Specifications And Approved Drawings, Including Packing & Forwarding, Transportation Charges For All Materials ( 8 Tone For Each Gates ) 9 Design, Drawing, Fabrication, Supply, Errection And Commissioning Of Trestle Assy / Railing Decking / Trash Rack / Structural Steel Hoist Bridge / Structural Steel Hoist Supporting Structure For Mono Rail / Catwalk Bridge For Connecting Spillway Piers For All Type Of Sluice With Embedded Parts Consisting Of Clumns, Beams, Bracings, Stiffeners, Ties, Chequered Plate Covering, Hand Railing, Ladder Etc., With All Other Accessories For Operating Gates, Other Structure Including Cost Of All Materials, Machinery, Labour, Tools And Tackles, Cutting, Aligning, Anchoring, Welding, Finishing, Cleaning, Applying Two Coats Of Zinc Chromate Red Oxide Primer And Three Coats Of Approved Synthetic Enamel Paingt Etc., Complete As Per Specifications And Approved Drawings, Including Packing & Forwarding, Transportation Charges For Structural Steel Components And Other Materials. 10 Providing Casting , Dressjng And Assembling Of Cast Iron Ballast Weight Assembly Complete As Per Drawing With Testing , Including Cost Of All Materials As Cast Iron Ballast Weight , Suitable Type Tapped Threaded Hole With Nut Hook For Lifting In All Sides, With Machinery, Labour, Cutting, Aligning, Welding, Finishing, Cleaning, Etc., Complete As Per Specifications And Approved Drawings With All Lead And Lifts, Tools And Tackles Including Packing & Forwarding Tuansportation Charges For Stuuctural Steel Components And Other ( 3000Kg Each Gate & 2Nos ) 11 Replacement Of Rubber Seal And Wire Rope For Radial Gates Size 12.65Mx6.7M ( Nos-06 Gates ) &Sluice 12 Supplying And Fixing Flat Rubber Seals Andstainless Steel Counter Sunk Bolts / Nuts / Washers Of Approved Quality Including Cost Of All Materials, Labour, Removing Existing Worn-Out / Damaged Flat Type Rubber Seals From Gates, Cleaning Surface, Making Holes In New Seals, Fixing New Seals / Bolts / Nuts / Washers Tightly In Position, Scaffolding Etc.Complete. 13 Supplying And Fixing Z-Type Rubber Seals And Stainless Steel Counter Sunk Bolts / Nuts / Washers Of Approved Quality Including Cost Of Allmaterials, Labour, Removing Existing Worn-Out / Damaged Z- Type Rubber Seals From Gates, Cleaning Surface, Making Holes In New Seals Fixing New Seals Bolts / Nuts / Washers Tightly In Position, Scaffolding Etc. Complete. 14 Steel Wire Rope 6X37 Construction -Is : 2266 ( Fibre Core Wire Rope Diameter 24 Mm And Required Length 984 M ( 164 M Length For 1No Gate And Total 6 Nos Gates Hence Total Wire Rope Length= 164X6= 984M ) & ( Approx. Mass For 24 Mm Dia Wire = 2.19 Kg / M Calculation For Toatal Weight Of Wire Rope : 2.19*984= 2154.96 Kg ) 15 Laying Of Wire Rope, Lapping Of Cardium Compoond, Filling Lead In The Joints Of Wire Rope, Complete Alignment Of Gate With Test And Trial At Site 20% 16 V Clamp 3"" Size For Fitting Of Wire Rope 24 No. For Each Gate 17 Providing And Applying Cardium Compound Of Approved Quality To Wire Ropes Of Hoists / Gantry Cranes As Part Of Annual Maintenance Including Cost Of All Materials, Machinery, Labour Etc. Complete. 18 Transportation Charges With Utility Van And With Four Men ( Two Helper , One Welder And One Fitter ) With Welding Parts, Cutting Items And Extra Tools And Tackles Required For Fitting Work Gate Parts And Head Etc 19 Supplying And Fixing Bulb Type Teflon Cladded Rubber Seals And Stainless Steel Counter Sunk Bolts / Nuts / Washers Of Approved Quality Including Cost Of All Materials, Removing Existing Worn-Out / Damaged Bulb Type Rubber Seals From Gates, Cleaning Surface, Making Holes In New Seals, Fixing New Seals / Bolts / Nuts / Washers Tightly In Position, Labour, Scaffolding Etc. Complete. ( For Sluice Gate ) 20 Painting Ofradial Gates & Sluice Gates 21 Painting Of Spillway Gates, Sluice Gates, Canal Gates ( Both Vertical Or Radial ) , Stop Loggates, Exposedembeddedpartsandallunmachinedferroussurface ( Hoist Cylinders, Cylinder Heads, Hydraulic Piping, Pipe Fittings, Bonnet Covers ) , Exposed To Water As Per Is 14177, For Which Surface Preparation By Blast Cleaning Of Class "B" Primercoat ( Onecoat ) Ofinorganiczincsilicate ( Preferably Airless Spray ) Or Alternatively, Two Coats Of Zinc Rich Primer ( Containing Not Less Than 85% Zinc On Dry Film ) To Give Dry Film Thickness Of 70 ± 5 Micron And Finish Coat ( Two Coats ) Of Solvent Less Coal Tar Epoxy Paint Using Airless Spray To Provide Dry Film Thickness Of150±5Micronpercoats.Thus, Totaldryfilmthicknessofallthecoats, Including Primer Coating, Should Not Be Less Than 350 Microns, This Will Be Include Expenses On Mobilisation And Demobilisation Of Equipments.For Maintenancepaintingthesurfacepreparationshallbedonebyappropriate Hand And Power Tool Cleaning, Prior To Hand Power Tool Cleaning. Any Heavy Layer Of Rust Should Be Removed By Chipping Visibleoil, Grease, Dirt And Other Foreign Materialbecleanedusingsolventslikecleanmineralspirits, Xylotorwhite Gasoline.Afterhandandpowertoolcleaningthesurfaceshouldbecleanedof Loose Dust And Debris And / Or Blast Cleaned As Laid Down In Para 7.0 Ofiscode14177.Afterthesurfacepreparationtheprimerandfinishingcoats Shall Be Carried Out As Provided Above For Painting Etc. Complete Upto 1.5M Height. 22 Beyond 1.5M Height 23 Painting Of Structural Components Of Hoist Including Supporting Structrures And Surfaces Of Hydraulic Hoist Sun Exposed To Water As Per Is:14177, For Which Surface Preparation By Blast Cleaning Of Class "B" , Primer Coat ( Two Coats ) Of Zinc Phosphate Primer To Give Dry Film Thickness Of 40 + 5 Micross Per Coat And Finish Coat ( One Coat ) Of Alkyd Based Micaceous Iron Oxide Paint Give Dry Film Thickness Of 65 + 5 Microns Followed By Two Coats Of Synthetic Enamel Paint, Using Airless Pray, To Give Dry Film Thickness Of 25+ 5 Microns Per Ost, At An Interval Of 24 Hours.Thus Total Dry Film Thikness Of All The Coats, Including Primer Coating, Should Not Be Less Than 175 Microns This Willinclude Expenses On Mobilisation And Demobilisation Of Equipment"S.For Maintenance Painting, The Surface Preparation Shall Be Done By Appropriate Hand And Power Tool Cleaning.Prior To Hand And Power Tool Cleaning, Any Heavy Layer Of Rust Should Be Removed By Chipping, Visible Oil, Grease, Dirt And Other Foreign Material Be Cleaned Using Solvents Like Cleanmineral Spirits, Xylol Or White Gasoline. After Hand And Power Tool Cleaning, The Surface Should Be Ckeabed If Kiise Dust And Debri Sand / Or Blast Cleaned As Laid Down In Para 7.0 Of Is Code 14177. After The Surface Preparation, The Primer And Finishing Coats Shall Be Carried Out As Provided Above For Painting Etc. Complete.Up To 1.5 Height ( Area Includes Walkway Bridge& Sluice Platform 802.32+139.6936=942 Sqm ) 24 Beyond 1.5 Height ( Radial Gate Hoist Bridge & Gear Assembly ) 25 Painting Of Lifting Beam / Lifting ( Trunion Section ) Are Per Is: 14177, For Which Surface Preparation By Blast Cleaning, As Per Class"C" Or Class "B", Primer Coast ( Two Coats ) Of Sinc Phosphate Primer, To Provide Dry Film Thickness Of 40 Microns Per Coat And Finish Coat ( Two Coats ) Of Alkyd Based Micaceous Iron Oxide Paint, Using Airless Spray, To Provide Minimum Dry Film Thickness Of 65 + 5 Microns Per Coat At An Interval Of 24 Hours. Thus, Total Dry Film Thickness Of All The Coats, Including Primer Coating, Should Not Be Less Than 200 Microns.This Willinclude Expenses On Mobilisation And Demobilisationof Equipment"S For Maintenane Painting, The Surface Preparation Should Be Done By Appropriatehand And Power Tool Cleaning. Prior To Hand And Power Tool Cleaning, Any Heavy Layer Of Rust Should Be Removed By Chipping. Visible Oil, Grease, Dirt And Otherforeign Material Be Cleaned Using Solvents Like Clean Mineral Spirits, Xylol Or Which Gasoline. Afterhandand Power Tool Cleaning, The Surface Should Be Cleaned Of Loose Dust And Debris And / Or Blast Cleaned As Laid Down In Para 7.0 Of Is Code 14177. After The Surface Preparation, The Primer And Finishing Coats Shall Be Carried Out As Provide Above For Painting Etc. Complete. 26 11 / 0.4 Kv, 100Kva , 63 Kva Out Door Sub-Station ( On H-Beam ) 27 Dtr 11 / 0.4 Kv Ee-Level-3100 Kva 28 H-Beams 152 X 152 Mm., 37.1 Kg. / Mtr.-11 Mtr. Long = 408.1 Kg 29 D.C.Cross-Arm Of 100 X50x 6 Mm. 8" Centre 30 Clampfor H-Beam Size-800 Mm , Wt-3.2 Kg Using 65X8ms Flat 31 11 Kv ( 45Kn ) 16Mm Frp With 25Mm Per Kv Creepage Disc Insulator Polymer 32 11Kv Strain Hard Ware Fitting 33 11 Kv D.O. Fuse & Lightening Arrestor Mounting Channel ( 75X 40 X 6 Mm. ) 34 Back Clampfor H-Beam Size-480 Mm , Wt- 1.92 Kg Using 65X8ms Flat 35 11 Kv D.O. Fuse Unit 36 9 Kvgapless Type ( 5Ka ) Polymer For Dtr 37 Transformer Mounting Dc Cross-Arm 100 X 50 X6 Mm. Channel 38 Transformer Belting With 50 X 50 X 6 Mm.Angle With Two Cross Fixing Channels 39 Clampfor H-Beam Size-, Wt-3.2 Kg Using 65X8ms Flat 40 Stay Set 16 Mm. Paintedcomplete Withturn Buckles 41 Stay Wire 7 / 3.15 Mm. ( 7.5 Kg.Stay Wire Per Stayset ) 42 Clampfor H-Beam Size-, Wt-3.2 Kg Using 65X8ms Flat 43 Stone Block / Pre Cast Block For Base Pedding 450X450x75mm 44 Concreting Of H-Beam@ 0.70 Cmt. Per Pole With Muffing 45 Concreting Of Stay @ 0.2 Cmt. Per Stay 46 Aaa Conductor Rabbit For Jumper 47 Danger Boards Enamalled Type 11Kv 48 Ht Bi-Metallic Clamp For Dtr 49 Lt Bi-Metallic Clamp For Dtr 12 Mm 50 Anti Climbing Devices ( Barbed Wire 2.24 Mm Dia ( 14 Swg ) ( 3.5 Kg. Wire Per Pole ) 51 Red Oxide Paint 52 Aluminium Paint 53 M.S.Nuts And Bolts 54 Distribution Box Mounting Channel ( 75X40x6 Mm. ) 55 Back Clampfor H-Beam Size- , Wt-1.92 Kg Using 65X8ms Flat 56 L.T. Distribution Box Suitable For 100 Kva Transformer ( Without Tpn Switches ) With Mccb On Incoming And Pf Units On Outgoing Side 57 70 Sq.Mm., Single Core Xlpe Insulatedun- Armoured Aluminium Conductor Cable 58 150 Sq.Mm., Single Core Xlpe Insulated Un- Armoured Aluminium Conductor Cable 59 11 Kv A.B. Switch 60 Dtr Meter 61 Supply & Fixing Fencing Of Chain Link Mesh 100 X 100 Mm, 12 Swg Gi Wire For Electric Sub-Station Switch Yard Including Single Post Of Angle Iron Size 50X50x5mm, 2.5 Mt Long Should Be Provided Upto 2.00 Mt. Apart Or As Required With Angle Iron / Flat Iron Members / Cross Members Including Mesh Fix On Frame And Erected Between The Post. The Angle Iron Post Shall Be Erected In Cement Concrete M- 15 ( 1:2:4 ) ( 20 Mm Graded Metal ) Foundation, Cement Concrete, Excavation Of Pit And Refilling The Same. The Fencing Shall Be Provided With One Entrance Gate Including Locking Arrangement As Required As Per Specification. The Height Of Fencing Shall Be 2 Mt. Above Ground Level. Fencing Shall Bepainted With Required Shade. 62 Providing & Fixing Perforated Cable Tray 300 Mm Wide & 2 Mm Thick Fixed On 45X45x5 Mm M.S. Angle Stand Grouted In C.C 1:24 63 Procedure To Avoid Grass In Sub-Station Yard- Black Cotton. By Laying Stone Cursher Dust. Base Rates Combined For Both The Layers Detailed In ( E-1 ) And ( E-2 ) In Civil Stock. 64 Supplying & Fixing Of Fire Extinguisher / Refills As Per Is Specification 4 Buckets Set With Sand, Self-Supported M.S. Stand I / C Shed Duly Painted With Red Colour As Per Is. 65 Supplying & Fixing Of Fire Extinguisher / Refills As Per Is Specificationabc Type Duly Refilled 6 Kg & Ready To Use 66 Supply Of Rubber Mat 2 X 1.0Mtr, 1100V Tested For Penal Rooms 67 Aaac Conductor Rabbit With 3 % Sag 68 Jointing Sleeves Suitable For 55 Sq. Mm.Al. Eq. Aaac Conductor 69 140 Kg., 8.0 Mtr. Long Pcc Support 70 A.B Cable Hanging Clamps / Tension Clamps ( Galvanized ) 71 1100 Volts Grade Aerial Bunched Xlpecable3 X50 + 1 X 16 + 1 X 35 Sq.Mm. ( Insulated Nuetral Massenger ) 72 Labour Charges 73 Transportation Charges 74 Diesel Generator 75 Supply Installation, Testing & Commissioning Of Diesel Generating Set, Three Phase And Water Cooled With Amf Control Panel. 40Kva 415 76 Supply Of Xlpe Insulated Power Cable ( Conforming Is-7098 Part-I ) 1100 Volt Grade, 1 Core / 2 Core / 3½Core / 4 Core Isi Marked With Alu. Stranded / Solid Conductor Marked With Alu. Stranded / Solid Conductor 4 Core Armoured 85 Sq. Mm 77 Earthing With G.I. Earth Plate 600Mm X600mmx6mm Thickincluding Accessories And Providing Masonry Encloser In Cement Mortar, Cover Plate Having Locking Arrangement On The Top And G.I. Watering Pipe 20Mm Dia 2.7 Metre Long Etc. ( But Without Charcoal Or Coke And Salt ) Complete As Required ( Copper Cable Option ) 78 Add Extra For Using Salt And Charcoal / Coke For G.I. Plate Or Copper Plate Earth Electrode As Required Including Excavation And Refilling The Pit In All Type Of Soil, Murrum 79 Change Over Switches ( Off Load ) Supplying Of Isi Marked Change Over Switches In Sheet Enclosure Conforming To Is : 4064 / Is : 13947 ( Part I & Iii ) With Side Handle Operated 4 Pole With Two Earthing Terminals. 63Amp 415 / 500 Volts. ( Off Load ) 80 Supply And Laying 25Mm X 5Mm G.I.Strip At 0.5 Metre Below Ground Level As Strip Earth Electrode Including Jointing Etc. As Required 81 Streetlight Ofleftflank , Centralspillway Trunnionlevelandright Flank, Rest House, Dam Areas 82 Supply Of Steel Tubular Pole Swaged Type As Per Is:2713-1980 Complete With Base Plate And Top Canopy - 410 Sp-11 - 8.00 Meter With Labour And Compelet. 83 Erection Of Rs Joist Pole / "H" Beam / Steel Tubular / Steel Rail Pole Of Length 7 Meters But Not Exceeding 10 Meters In Cement Concrete 1:3:6 ( 1 Cement : 3 Core Sand: 6 Graded Stone Aggregate 40Mm Nominal Size ) Base, Foundation, Muffing Including Excavation And Back Refilling Etc. As Complet Required. 84 Supplying Of Isi Marked And Accepted Standard Of Miniature Circuit Breaker ( Mcb ) Of "C" Series Suitable For 240 / 415 Volts, 50 Cycle, 10 Ka Value Ac Supply Confirming To Is: 8828: 1996, Iec: 60898 :2002 But Without Enclosures: - Double Pole & Neutral ( Dpn ) 6 Amp To 32 Amp 10Karating 85 Mcb Fp 6Amp To 32Amp 10Ka Rating 86 Mcb Fp 50Amp To 63 Amp 10Ka Rating 87 Supplying & Fixing Of Waterproof Insulation Piercing Connector For Aerial Bunch Cable I / C Required Attachment For Single Core Cable Of Approved Make In Air With Necessary Material As Per Specification Of Required Size As Mentioned Below -Main: 16-95Sq.Mm, Tap: 1.5-50Sq.Mm 88 Supply Of Xlpe Insulated Power Cable ( Confirming Is-7098 Part-I ) 1100 Volt Grade, 1 Core / 2 Core / 3½ Core / 4 Core Isi Marked With Alu. Stranded / Solid Conductor - 4 Sq.Mm. ( For Connection Between Main Cable To Led ) 89 Supply And Fixing Street Light With High Power Led Of 3 To 6 Watt Each On Existing Bracket Assembled On Single Mcpcb And Additional Unique Peanut Lens On Each Led, System Lumens Output With Efficacy > 120 Lm / Watt. Luminiare Having Color Temp Upto 6500K & 50000 Hrs. Burning Life With Minimum @ L 70, The Colour Rendering Index Of Led Light Should Be More Than 70 Luminiare Comprises Of Driver, Pf> 0.95 & Surge Protection 10Kv. Housing Made Of Pressure Die Cast Aluminium With Heat Resistant Flat Glass, Ip65 Protection. Submission Lm 79- 08 / Is16106 ( 2012 ) , Iec60598, Iec61347 I / C Connection Wire, Testing Etc. To Complete The Job 60 Watt To 48Watt, Color Temp 3000 - 6500K Asrequired. 90 Supplying And Erection Of Water Tight Terminal Box Made Of 16 Swg M.S. Sheet ( 1.6Mm Thick ) I / C Rubber Gasket Of Required Size Suitable For Kit Kat / Mcb / Switch Including 2 Nos. Pole Clamp Of M.S. Flat Iron Size 32X3mm, Nut And Bolts, 4 Pole Epoxy Connector Nut & Bolt Type, 30Amp., 500Volt. The Box Shall Be Powder Coated. Excluding The Cost Of The Kit Kat / Mcb / Switch Complete As Per Specification. 30X20x10 Cms. 91 Supplying & Fixing Pin Terminal Lugs As Per Iss Specification Suitable For Cable Evenly Cramped With High Pressure Tool & Connection To Switch Gear Terminal. Copper Lugs Pin Type Up To 16 Sq.Mm2 Conductor Size 92 Supplying & Fixing Pin Terminal Lugs As Per Iss Specification Suitable For Cable Evenly Cramped With High Pressure Tool & Connection To Switch Gear Terminal.Copper Lugs Tube Type Up To 16 Sq.Mm2 Conductor Size 93 Supplying & Fixing Pin Terminal Lugs As Per Iss Specification Suitable For Cable Evenly Cramped With High Pressure Tool & Connection To Switch Gear Terminal.Aluminum Lugs Tube Type 25 Sq.Mm Conductor Size 94 Supply Of Xlpe Insulated Power Cable ( Confirming Is-7098 Part-I ) 1100 Volt Grade, 1 Core / 2 Core / 3½ Core / 4 Core Isi Marked With Alu. Stranded / Solid Conductor 3½ Core Armoured 95 Sq.Mm ( From Control Room To Sluice Hoist ) 95 Supply Of Xlpe Insulated Power Cable ( Confirming Is-7098 Part-I ) 1100 Volt Grade, 1 Core / 2 Core / 3½ Core / 4 Core Isi Marked With Alu. Stranded / Solid Conductor 3½ Core Armoured 25 Sq.Mm ( From Control Room To Radial Gate, Eot Crane & Sluice Hoist Motor ) 96 Supply Of Xlpe Insulated Power Cable ( Confirming Is-7098 Part-I ) 1100 Volt Grade, 1 Core / 2 Core / 3½ Core / 4 Core Isi Marked With Alu. Stranded / Solid Conductor 3 Core Armoured 10 Sq.Mm ( Street Lighting ) 97 Supply And Erecting Of Perforated Type Fiber Glass Reinforced Polymer ( Frp ) / Glass Fiber Reinforced Polymer ( Grp ) Cable Tray Of Specific Dimensions. The Cable Tray Shall Be Hung From Ceiling / Fixed To Wall With Necessary Angle / Flat Iron Ceiling 100 Mm Width With Straight Coupler Plate Size: 200 X 25 X 4 Mm & 8 Sets Of Ss 304 Hardware Size: M5x20mm ( For Stoplock Eot & Walk-Way Bridge ) 98 150 Mm Width With Straight Coupler Plate Size: 200 X 25 X 4 Mm & 8 Sets Of Ss 304 Hardware Size: M5x20mm ( For Sluice Hoist ) 99 300 Mm Width With Straight Coupler Plate Size: 200 X 25 X 4 Mm & 8 Sets Of Ss 304 Hardware Size: M5x20mm ( For Radial Gate ) 100 Supplying, Fixing, Testing & Commissioning Wall / Floor Mounted Lt Panel Primer Coated With Powder Coated Paint& Provided With Required Gasket For Dust / Vermin Proof With Degree Of Protection Ip42 Suitable For 415V 3 Phase, 50 Hz, 4 Wire System Fabricated Out Of Crca Sheet Up To 2 Mm Thick ( 1.6 Mm For Doors ) Duly Compartmentalized For Comer, Bus Section, Outgoings, Cable Alleys & Ct, Pt Ampere Meter, Volt Meter, Selector Switches, Frequency Meter, Phase Indicating Lamps, Energy Meter Complete Including Cost Of Busbar Supports, Detachable Cable Gland Plates, 2 Earthing Terminals, Internal Wiring & Fixing Of Separately Supplied Mcbs, Mccbs , Acb, Panel Mounted Changeover Switch / Sfus, Etc. Asrequired But Excluding Cost Of Bus Bar Strips, Ampere Meter, Volt Meter, Selector Switch As Per Approved Design & Specification 101 Supply And Laying 4Mm Dia. Copper Wire At 0.5 Metre Below Ground Level As Conductor Earth Electrode Including Soldering Etc. As Required 102 Supply And Drawing Pvc Insulated Copper Cable ( Earth Continuity Conductor ) Of Green Colour Frls With Copper Multi Strand Conductor Isi Mark In Existing Conduit Along With Other Wires As Required As Per Specification : 4Sq. Mm 103 Supplying And Installing Double Wall Corrugated Pipes ( Dwc ) Of Hdpe ( Is 14930 Part Ii -Marked ) For Cable Laid Underground With Necessary Material And At Required Depth Upto 90Cm. Below Road / Ground Surface, Including Excavation, Back Filling With Excavated Material, Ramming And Making The Surface Good.50.00Mm Outside Dia. 104 Laying Of One Number Armoured / Unarmouredcable 1.1Kv Grade Of Size Exceeding 25 Sq. Mm But Not Exceeding 120 Sq. Mm On Surface In Existing Trench Etc. As Required. 105 Laying Of One Number Armoured / Unarmoured Cable 1.1Kv Grade Of Size Not Exceeding 25 Sq. Mm On Surface In Existing Trench Etc. As Required 106 Providing Back Filling Bentonite Compound Suitable For Safe Earthing Device. The Product Should Be Ul Listed And Confirm To Relevant International / Indian Standards 107 Supplying And Fixing Of Lt Panel Accessories Of Approved Make In Existing Lt Panel Including Connections Etc.As Required As Per Specification Digital Ampere Meter With Cts With Selector Switch 108 Digital Volt Meter With Selector Switch & Hrc Fuse 109 Copper Bus Bar Strips With Pvc Sleeves 110 Led Lamp Indicator 111 Mccb 25 To 100A, 25Ka, 3P Mccb 25Ka Current Rating, 3P -25 To 100Amp & 80% -100% Adjustable 112 Mccb 25Ka Current Rating, 3P -200Amp & 80% -100% Adjustable 113 High Mast 114 Supply And Fixing Street Light With High Power Led Of 3 To 6 Watt Each On Existing Bracket Assembled On Single Mcpcb And Additional Unique Peanut Lens On Each Led, System Lumens Outputwith Efficacy>120 Lm / Watt. Luminiare Havingcolor Temp Upto 6500K & 50000 Hrs. Burning Life With Minimum @ L 70, The Colour Rendering Index Of Led Light Should Be More Than 70. Luminiare Comprises Of Driver, Pf> 0.95 & Surge Protection 10Kv. Housing Made Of Pressure Die Cast Aluminium With Heat Resistant Flat Glass, Ip65 Protection. Submission Lm 7908 / Is16106 ( 2012 ) , Iec60598, Iec61347 I / C Connection Wire, Testing Etc. To Complete The Job.150Watt, Color Temp 3000-6500K As Required. 115 Supply And Fixing Of Multi Core Round Frlsh Pvc Insulated Copper ( Flexible ) Conductor & Pvc Sheathed Cables 1100Volts As Per Is:694-1990 Of Approved Make ( 50 / 0.25 Mm ) Three Core 2.5 Sq.Mm. 116 Supply Of Feeder Pillar Made Of 16 Gauge Thick M.S.Powder Coated With Angle Iron Stand Double Door Panel Suitable For 20 Mtr. High Mast Lighting Assembly Including Connector Strip 4 Way 2 Nos , Mcb 63 A 4 Pole -1 No., Contactor Mn 32 A -1 No, Timer Manual L& T Make 1 No. , Mcb 6 Amp For Timer 1No., Toggle Switch 1No , Lower And Upper Push Button 2 Nos., 3 Phase Changeover Switch 16 A For Raising Lowering 1 No , Cable Gland Suitable For 25 Sqmm Cable Panel Main Wiring 10 Sqmm Copper Wire . 117 Labour Charge For Repairing Of High Mast Assembly At Suktadam Site Including Opening Of Mast Control Cover , Lowering Of Mast Bulb Assemblyand After Repairing / Replacement Of Burnt Damaged Lighting With New Led Lighting Raising Ofbulb Assembly Including Setting Of Lamp Focus Etc. Only. Laboure Charge Of Completework At Site .
|