X-Ray Devices - Framework Agreement For C-Arms Ukl. The Plan Is To Gradually Replace A Total Of 8 Mobile X-Ray Fluoroscopy Systems Over A Period Of 48 Months. There Are Three Device Configurations With Different Requirement Profiles From The Same Manufacturer Are Needed To Ensure Interoperability And Simplified To Ensure Service Logistics. Requirements: 2024: 1 X Standard, 1 X 3D, 1 X Compact 2025: 2 X Compact 2026: 1 X Standard, 1 X Compact 2027: 2 X Standard The Client Reserves The Right To Decide On The Number Of Units Purchased Within Each Year Increases Or Decreases Of Up To 20%, Which Do Not Affect The Price Structure Offered May! Requirement Profile 1: Standalone Compact System With Monitor Swivel Arm Planned Is The Replacement Procurement Of Stand-Alone, Compact, Mobile C-Arms For Simple Diagnostic And Interventional Applications In Orthopedics, Traumatology And Pain Therapy. The System Must Be Easy To Maneuver And Complete In The Tightest Of Spaces Can Be Operated On The C Mobile Stand. Requirement Profile 2: Two-Part System With Monitor Trolley The Plan Is To Purchase Replacement Mobile C-Arms With A Separate Monitor Trolley And The Possibility Of Subconfiguration For Simple Interventional Procedures In From Orthopedics, Traumatology, Pain Therapy To Sophisticated Surgical Interventions In Spinal, Cardiac And Vascular Surgery As Well As Neurosurgery And Ercp With Long-Term Operations. This Requires At Least An Optional Configuration Be Available With Rotating Anode, Active Cooling And Dsa Mode. Requirement Profile 3: Two-Part System With Monitor Trolley And 3D Function. Replacement Procurement Is Planned Of Mobile C-Arms With Separate Monitor Trolley And 3D Function For Complex Surgical Interventions In Orthopedics, Neurosurgery, Spinal And Emergency Surgery As Well For Multidisciplinary Interventions With Long-Term Operations. The System Must Enable Precise Motorized Orbital, Angulation And Horizontal Movement. Overarching Requirements For All Profiles All Systems Must Have A Broad Spectrum Provide Examination Protocols And Characteristic Curves For Adults, Children And Infants. In Addition, All Systems Should Be Equipped With High-Resolution Cmos Flat Detectors And Pulsed High-Frequency X-Ray Generators And Wireless Foot Switches. The Fluoroscopy Must Be In Mains Operation Be Possible Without The Use Of Additional Batteries And All Translation And Rotation Axes, In Addition To The Height Adjustment, Also Manually And Mechanically Adjustable.
Contact Information
Contact Person
Bereich 2 - Materialwirtschaft u. Dienstleistungen
Address
Liebigstr. 18, Haus B
Contact No.
+49228996100
Email
esender_hub@bescha.bund.de
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 72946377
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.