Works For Complete Or Part Construction And Civil Engineering Work - Water Plant Development. The Task Of The Winning Company Is To Carry Out Construction Works Related To The Development Of A Water Plant In Accordance With The Md, Which Is Part Of The Ekd, The Main Quantitative Data Below According To: Water Treatment Building - Architecture - Making A Bridge 14 Pcs. - Replacement Plating Production (With 40 Cm Slat Spacing) 465 M2 - Osb Covering On The Inner Plane Of The Roof 357 M2 - Tile Cover In Natural Color (With Ventilation Tile, Snow Grip And Other Accessories) 465 M2 - Construction Of 30 Cm Thick Brickwork 464 M2 - Monolithic Plasterboard False Ceiling Construction 19.6 M2 - Facade Thin Plaster In White Color 190.5 M2 - Leveling Of Sockets Preparation + Foundation 376.3 M2 - Installation Of Hanging Gutter 47.2 M - Roof Side 45.2 M - 2 Layers Of Painting On An Inclined Surface (Inclined False Ceiling) In White Color 357 M2 - External Wall; Facade Wall Thermal Insulation 322 M2 - Creation Of A 3D Fence 407 M Water Treatment Building - Structure Construction - Excavation By Machine With Force 780 M3 - Soil Backfilling With Mechanical Force 353 M3 - Construction Of Watertight Walling 151.2 M2 - Concreting Of Base Plate 30.8 M3 - Columns, Formwork Stone Wall, Beams And Wreaths Concreting 20.2 M3 - Making A Catwalk In The Pump House 1416 Kg - Earthing Connections Installation Of 20 Units Water Treatment Building - Building Mechanical Engineering - Heating Panel 2 Units - Pvc Drain Line Installation (Dn 50) 20 M - Installation Of Five-Layer Plastic Pipe (D25x2.5) 22 M - Circular Cross-Section Air Valve For Extraction 2 Pcs - Pvc Sewer Pipe (D = 110 Mm) 11 M Water Treatment Building – Electrical Installation - Indoor Wall Cabinet With Ip66 Protection (Rated Voltage: 400/230 V, 50 Hz, Rated Current: Max. 63A, Short-Circuit Strength: 6 Kaeff, External Size 600X500x250mm) 1 Pc - Surge Protection 4 Pcs - Bracket Mounted 2X25w, 1500Mm Long Fluorescent Lamp, For 2 Pcs T8 Led Fluorescent Tubes (Protection: Ip65) 35 Pcs - T8 Led 25W Total. Fluorescent Tube (Warm White, Size 1500Mm) 70 Pcs - Double Corner External 6A Waterproof Switch, Ip65 9 Pcs - 2P+Pe Single-Phase, 16A, Protective Contact, Recessed Socket 7 Pcs - Mcu 1X1.5 Mm2 Blue Solid Copper Pvc Insulated 450/750V Solid Wire, With Different Colors, Pulled Into A Protective Tube 100 M - Nyy-J 0.6/1 Kv Type, Copper-Conductor, Plastic-Insulated 0.4Kv Power Transmission Cable, In Cable Trench, Cable Channel, Respectively Guided On A Supporting Structure 220 M Water Treatment Building – Technology Mechanical Engineering - Pumping Station Installation Of Stainless Steel Pipelines Freely, With Fittings, Flanges, Joints; By Rinsing, With Disinfection And Pressure Test 1783 Kg Yard Work - Preparation Of Sand Bed 350 M2 - Concreting Of Slabs 4.5 M3 - Iron Installation Of Reinforced Substrate 170 Kg - Sand Gravel Bed 86 M3 - Preparation Of Concrete For Concrete Work Road 92 M3 - Preparation Of Prefabricated Pavement Construction Of A 40 M2 Waste Water Plant From Concrete Pavements - Excavation 560 M3 - Sand Gravel Bedding 25.2 M3 - Concreting Base Plate 34.9 M3 - Iron Installation Of Walls 4792 Kg - Steel Ladder 86 Kg Mechanical Engineering Of A Slurry Water Settler - Technological Mechanical Installation Of A Slurry Water Settler 150 Kg - Making And Placing The Extension Lead Sleeve Electrical Equipment, Wiring - 400A Circuit Breaker (With Micrologic 2.0 Protection, Mx, Of Auxiliary Relay, Highlighted With Motor Drive, Electric Locking Between Circuit Breakers In=400A, Iz= 36Ka) 2 Pcs - Current Transformer (400/5A, 2.5Va, Ac0.5) 4 Pcs - Terminal Fuse 25 Pcs - 230V 8A Relay 4 Pcs - 230Vac Relay, With Socket 2P 7 Pcs - Plug With Tap Cover 2P+F 6 Pcs - 3X400v (55Kw) Frequency Converter (Protection: Ip55) 3 Pcs - Designing Cable Trenches, Laying The Cables With Backfilling (Soil Backfilling Completely In Approx. 600Mm Width) 60 M - Construction Of Cable Trenches, With Backfilling After Laying The Cables (Soil Backfilling Completely Approx. 400Mm Wide) 300 M - 250X60 Mm Perforated, Hot-Dip Galvanized Steel Cable Duct With Cover 75 M - Fuse Terminal Block With Different Inserts 10 Pcs - 12 Digital Input Cards - 1 Changeover Contact Relay With 24Vdc Coil Voltage 244 Pcs - Galvanic Isolation Power Supply 32 Pcs - 88X88x50 Junction Box 3 Pcs - Frequency Converters Commissioning, Testing, Programming, Adjustment (6Fv100, 6Fv200, 6Fv300, 7Fv100, 7Fv200) 5 Pcs Lightning Protection - Arresting Rod Ø 10 Mm Aluminum, Arresting Rod Holder 11 Pcs - Roof Cable Holder 160 Pcs - Roof Cable 165 M - Arrester 60 M - Cable Holder Ø 8-10 60 Pcs Per Mm Circular Wire - Potential Equalization At Tailings Settler 10 M - Site Grounding Network: Double Connecting And Connecting Clips Suitable For One And Two Circuit Conductors 30 Pcs. Site Earthing Network: For The Earthing Supervisor, Trench Digging With Reburial 1 Meter Deep 198 M The Detailed Description Of The Tasks To Be Performed Is Part Of The Ekd Md Included.
|