Centralized Medical Gas Supply For Gmc Palakkad , Sitc Of Main Oxygen Manifold 20 + 20 Cylinders With Nrvs, Tail Pipes, Middle Frame With Chain. , Sitc Ofo2 Control Panel-Fully Automatic , Sitc Ofemergency Reserve Oxygen Manifold 6 + 6 Cylinder With Nrvs, Tail Pipes, Middle Frame. , Gas Consumption Meter Totalizer - Oxygen 2000 Lpm Capacity. , Sitc Ofmain Nitrous Oxide Manifold 6 + 6 Cylinders With Nrvs, Tail Pipes. , Sitc Ofn2o Control Panel-Fully Automatic - Imported , Sitc Ofemergency Reserve N2o Manifold 2 + 2Cylinder With Nrvs, Tail Pipes. , Sitc Ofmain Carbon Di-Oxide Manifold 3 + 3 Cylinders With Nrvs, Tail Pipes. , Sitc Of Co2 Control Panel-Fully Automatic - Imported , Sitc Ofemergency Reserve Co2 Manifold 1 + 1Cylinder With Nrvs, Tail Pipes. , Sitc Of Medicalcompressed Air Plant (Package Unit) As Per Given Technical Specifications , Sitc Of Surgical Air Plant (Package Unit) As Per Given Technical Specifications , Sitc Of Vacuum Central System (Package Unit) As Per Given Technical Specifications , Sitc Ofanesthesia Gas Scavenging System As Per Technical Specifications , Sitc Of Copper Pipe 12 Mm Od X 0.7 Mm Thk , Sitc Of Copper Pipe 15 Mm Od X 0.9 Mm Thk , Sitc Of Copper Pipe 22 Mm Od X 0.9 Mm Thk , Sitc Of Copper Pipe 28 Mm Od X 0.9 Mm Thk , Sitc Of Copper Pipe 35 Mm Od X 1.2 Mm Thk , Sitc Of Copper Pipe 42 Mm Od X 1.2 Mm Thk , Sitc Of Copper Pipe 54 Mm Od X 1.2 Mm Thk , Sitc Of Copper Pipe 76 Mm Od X 1.2 Mm Thk , Sitc Of Copper Pipe 108 Mm Od X 1.5 Mm Thk , Sitc Of Valve And Valve Box With Pressure Gauge 2 Gas , Sitc Of Valve And Valve Box With Pressure Gauge 3 Gas , Sitc Of Valve And Valve Box With Pressure Gauge 4 Gas , Sitc Of Valve And Valve Box With Pressure Gauge 5 Gas , Sitc Of Valve And Valve Box With Pressure Gauge 6 Gas , Sitc Ofelectrical All Control Panel For Air And Vacuum Compressors And Agss , Sitc Ofbed Head Panel - Length - 1200 Mm , Sitc Ofbed Head Panel - Length - 1500 Mm , Ceiling Rigid Pendant , Single Arm Anaesthesia Pendant , Double Arm Surgen Pendant , Sitc Ofmaster Alarm - Medical Gas , Sitc Of Area Alarm 2 Gas Service , Sitc Of Area Alarm 3 Gas Service , Sitc Of Area Alarm 4 Gas Service , Sitc Of Area Alarm 5 Gas Service , Sitc Of Area Alarm 6 Gas Service , Sitc Of Isolation Valves And Brass Adapter 12 Mm , Sitc Of Isolation Valves And Brass Adapter 15 Mm , Sitc Of Isolation Valves And Brass Adapter 22 Mm , Sitc Of Isolation Valves And Brass Adapter 28 Mm , Sitc Of Isolation Valves And Brass Adapter 35 Mm , Sitc Of Isolation Valves And Brass Adapter 42 Mm , Sitc Of Isolation Valves And Brass Adapter 54 Mm , Sitc Of Isolation Valves And Brass Adapter 76 Mm , Sitc Of Isolation Valves And Brass Adapter 108 Mm , Sitc Of Gas Outlets Imported , Sitc Of Imported Agss Outlet , Sitc Of Matching Probes For Gas Termical Units , Sitc Of Matching Agss Probes For Gas Termical Units , Oxygen Flow Meter With Humidifier And Adapter , Ward Vacuum Unit With 600 Ml Jar With Tubing , Low Flow Vacuum Unit With Tubing , Theatre Vacuum Unit With Tubing , Hp Tube Antistatic , 5 A Socket , 5/15 A Socket , Switch 5 A , Switch 15A , Rj 45 Data Outlet , Rj 11 Telephone Socket , Monitor Stand For Fixing With Bed Head Panel , Cylinder Filled - Oxygen D Type , Cylinder Filled -Nitrous Oxide D Type , Cylinder Filled - Carbon Di Oxide D Type , Rate For Concealing Area Valve Box/Alarm Unit Including Replastering , Rate For Concealing Copper Pipeline Including Replastering , Rate For Concealing Gas Outlets-Wards, Including Replastering , Internal Wiring Charges For All Power Sockets With Switch For One Bed Head Unit / Pendant , Sitc Of Gas Outlets Indigeneous (Not Taken For Evaluation) , Sitc Of Indigeneous Agss Outlet(Not Taken For Evaluation)
|