Electrical Items And Providing Electrical Works On Demand Based On Rate Contract At Kmio And Pcc Kalburgi , Wires & Cables Point Wiring Using Copper Wire Without Switch Supplying And Wiring Adopting Loop System In Existing Pvc Conduit / Casing Capping Using 1100 V Gradecopper Frls Pvc Insulated 2X15sqmmcable Confirming To The Gtp Without Switch The Other End Of The Wires Shall Be Terminated With Sufficient Loose Length In A Wood / Pvc Round Block Complete For Each Outlet 5 / 23 Medium Point Above 3Mtr Up To 6Mtr From Tapping Point To Out Let Via Switch Box ---- Etc., Complete With All Lead & Lift, As Per Specifications And As Per Directions Of The Engineer In Charge Of The Work Pg 3 Item 2.2.2 ( Sr22-23 ) Wire Make : Finolex / Anchor / Kei, Wires & Cables Point Wiring Using Copper Wire Without Switch Supplying And Wiring Adopting Loop System In Existing Pvc Conduit / Casing Capping Using 1100 V Gradecopper Frls Pvc Insulated 2X15sqmmcable Confirming To The Gtp Without Switch The Other End Of The Wires Shall Be Terminated With Sufficient Loose Length In A Wood / Pvc Round Block Complete For Each Outlet 5 / 23 Long Point Above 6Mtr Up To 10Mtr From Tapping Point To Out Let Via Switch Box ---- Etc., Complete With All Lead & Lift, As Per Specifications And As Per Directions Of The Engineer In Charge Of The Work Pg 3 Item 2.2.3 ( Sr22-23 ) Wire Make : Finolex / Anchor / Kei, Wires & Cables Point Wiring Using Copper Wire Without Switch Supplying And Wiring Adopting Loop System In Existing Pvc Conduit / Casing Capping Using 1100 V Grade Copper Frls Pvc Insulated 2X15sqmmcable Confirming To The Gtp Without Switch The Other End Of The Wires Shall Be Terminated With Sufficient Loose Length In A Wood / Pvc Round Block Complete For Each Outlet 5 / 23 Two Outlet In A Row Above 6Mts Up To 10Mtr From Tapping Point To Out Let Via Switches Box ---- Etc., Complete With All Lead & Lift, As Per Specifications And As Per Directions Of The Engineer In Charge Of The Work, Supplying Of Extension Boards With 3 Mtrs 1.5 Sqmm Copper Cable In Legth 10”X7” Wooden Board With Pvc Plate Comprising One No 16 Amps Socket, 20 Amps Switch, 3Nos Of 5 Amps Switch And 6 Amps Sockets 3Nos, Supplying Of Extension Boards With 5 Mtrs In Length 1.5 Sqmm Pvc Copper Cable , 10”X7” Wooden Board With Pvc Plate Comprising One No 16 Amps Socket, 20 Amps Switch, 2Nos Of 5 Amps Switch And 6 Amps Sockets 2Nos, Supplying And Fixing Of Pvc Casing And Capping On The Wall Or Ceiling Using Necessary Materials Like Bends , Screws At An Interval Of 300Mm …Etc As Required Pg 2 Item 1.8.1 20 Mm, Supplying And Fixing Of Pvc Casing And Capping On The Wall Or Ceiling Using Necessary Materials Like Bends , Screws At An Interval Of 300Mm …Etc As Required Pg 2 Item 1.8.2 25 Mm, Supplying And Fixing Of Pvc Casing And Capping On The Wall Oe R Ceiling Using Necessary Materials Like Bends , Screws At An Interval Of 300Mm …Etc As Required Pg 3 Item 1.8. 3 32 Mm, Supplying And Fixing Of Pvc Casing And Capping On The Wall Oe R Ceiling Using Necessary Materials Like Bends , Screws At An Interval Of 300Mm …Etc As Required Pg 3 Item 1.8. 4 38 Mm, Supplying And Fixing Of Pvc Casing And Capping On The Wall Oe R Ceiling Using Necessary Materials Like Bends , Screws At An Interval Of 300Mm …Etc As Required Pg 3 Item 1.8. 5 50 Mm, Supplying And Fixing Of Pvc Casing And Capping On The Wall Or Ceiling Using Necessary Materials Like Bends , Screws At An Interval Of 300Mm …Etc 50X100 Mm Industrial Type, Supplying And Fixing Of S” Hook Made Out Of 14, Mm Dia Pg 2 / 1.10, Providing Open Conduit System Supplying And Drawing Heavy Gauze Pvc Conduit Pipes19 / 20Mm Dia 2 Mmthick Conforming To Is 2509 With Suitable Size Bends , Junction Boxes, Adhesive Paste Etc.. Pg1 / 1.1.1 19 / 20Mm Dia 2 Mm Thick, Providing Open Conduit System Supplying And Drawing Heavy Gauze Pvc Conduit Pipes25 Mm Dia 2 Mmthick Conforming To Is 2509 With Suitable Size Bends , Junction Boxes, Adhesive Paste Etc.. Pg2 / 1.1.2 1.1.2 25 Mm Dia 2 Mm Thick, Providing Open Conduit System Supplying And Drawing Heavy Gauze Pvc Conduit Pipes32 Mm Dia 2.5 Mmthick Conforming To Is 2509 With Suitable Size Bends , Junction Boxes, Adhesive Paste Etc.. P1 / 1.1.3 1.1.3 32Mm Dia 2.5 Mm Thick, Providing Open Conduit System Supplying And Drawing Heavy Gauze Pvc Conduit Pipes40 Mm Dia 2.5 Mmthick Conforming To Is 2509 With Suitable Size Bends , Junction Boxes, Adhesive Paste Etc.. Pg 1 / 1.1.4 1.1.4, Concealed Conduit System: Supplying Heavy Gauge Pvc Conduit Pipe 19 / 20 Mm Dia 2Mm Thick Conforming To Is 2509 With Suitable Size Bends , Metal / Pvc Junction Boxes , Adhesive Paste Etc.. And Running Before Concreting The Slab . The Conduit Should Be Tied To The Reiforcemrnt Rods By Using Binding Wires And Unused Ways Of Junction Boxes And Pipe Ends Should Be Covered Using Pvc End Enclosures , Run With 18 Swg Gi Fish Wire Wherever Necessary Pg 1 / 1.2.1 1.2.1 19 / 20Mm Dia 2 Mm Thick, Concealed Conduit System: Supplying Heavy Gauge Pvc Conduit Pipe 19 / 20 Mm Dia 2Mm Thick Conforming To Is 2509 With Suitable Size Bends , Metal / Pvc Junction Boxes , Adhesive Paste Etc.. And Running Before Concreting The Slab . The Conduit Should Be Tied To The Reiforcemrnt Rods By Using Binding Wires And Unused Ways Of Junction Boxes And Pipe Ends Should Be Covered Using Pvc End Enclosures , Run With 18 Swg Gi Fish Wire Wherever Necessary Pg 1 / 1.2.1 1.2.2 25Mm Dia 2 Mm Thick, Concealed Conduit System: Supplying Heavy Gauge Pvc Conduit Pipe 19 / 20 Mm Dia 2Mm Thick Conforming To Is 2509 With Suitable Size Bends , Metal / Pvc Junction Boxes , Adhesive Paste Etc.. And Running Before Concreting The Slab . The Conduit Should Be Tied To The Reiforcemrnt Rods By Using Binding Wires And Unused Ways Of Junction Boxes And Pipe Ends Should Be Covered Using Pvc End Enclosures , Run With 18 Swg Gi Fish Wire Wherever Necessary Pg 1 / Item 1.2.3 1.2.3 32Mm Dia 2 Mm Thick, Providing Groove Cutting In The Wall And Fixing By Bracing U Or J Hooks And Cement Plastering Up To The Wall Surface And Run With 18 Swg Fish Wire Run Throught The Conduit Wherever Necessary Including Supplying And Fixing Of Heavy Gauge Pvc Conduit Pipe Pg 1 / 1.3.1 1.3.1 19 / 20 Mm Dia 2 Mm Thick, Providing Groove Cutting In The Wall And Fixing By Bracing U Or J Hooks And Cement Plastering Up To The Wall Surface And Run With 18 Swg Fish Wire Run Throught The Conduit Wherever Necessary Including Supplying And Fixing Of Heavy Gauge Pvc Conduit Pipe Pg 1 / 1.3.2 1.3.2 25 Mm Dia 2 Mm Thick, Providing Groove Cutting In The Wall And Fixing By Bracing U Or J Hooks And Cement Plastering Up To The Wall Surface And Run With 18 Swg Fish Wire Run Throught The Conduit Wherever Necessary Including Supplying And Fixing Of Heavy Gauge Pvc Conduit Pipe Pg 1 / 1.3.3 1.3.3 32 Mm Dia 2 Mm Thick, Providing Groove Cutting In The Wall And Fixing By Bracing U Or J Hooks And Cement Plastering Up To The Wall Surface And Run With 18 Swg Fish Wire Run Throught The Conduit Wherever Necessary Including Supplying And Fixing Of Heavy Gauge Pvc Conduit Pipe Pg 1 / 1.3.4 1.3.4 40 Mm Dia 2.5 Mm Thick, Supplying And Drawing Heavy Duty 2 Inch Pvc Pipe Thickness 3Mm, Supplying And Drawing Heavy Duty 2.5 Inch Pvc Pipe Thickness 3.25Mm, Supplying And Drawing Heavy Duty 3 Inch Pvc Pipe Thickness 3.5Mm, Providing Cpvc Pipe For Water Supply Line Including Labour Charges And Material Charges 19 / 20 Mm, Providing Plumbing Works For The Installation Of Geyser Including Supplying And Fixing Of Taps For Inlet And Out Let Cpvc Pipes And Inlet Control, Supplying And Fixing Sheet Metal Box Made Out Of 18 Swg Sheet Metal With Necessary Holes For Cable / Conduit Entry As Required With One Coat Of Primer Of Approved Make Etc Pg1 / 1.4.3 1.4.3 135X75x65mm, Supplying And Fixing Sheet Metal Box Made Out Of 18 Swg Sheet Metal With Necessary Holes For Cable / Conduit Entry As Required With One Coat Of Primer Of Approved Make Etc Pg 1 / 1.4.2 1.4.2 100X75x65mm, Supplying And Fixing Sheet Metal Box Made Out Of 18 Swg Sheet Metal With Necessary Holes For Cable / Conduit Entry As Required With One Coat Of Primer Of Approved Make Etc 1.4.1 75X75x65mm, Supplying And Fixing Pvc / Metal Conduit Deep Junction Box Pg 1 / 1.5.1 19 / 20 Mm Deep Junction Box, Supplying And Fixing Pvc / Metal Conduit Deep Junction Box Pg 1 / 1.5.2 25 Mm Deep Junction Box, Supplying And Fixing Pvc / Metal Conduit Deep Junction Box Pg 1 / 1.5.3 32 Mm Deep Junction Box, Supply And Fixing / Replacing Of 6 / 16 / 32 Amps Electrical Accessories On Existing Switch Board Pg 6 Item 3.14.1 Group A 3.14.1 6 Amps Sp Switch, Supply And Fixing / Replacing Of 6 / 16 / 32 Amps Electrical Accessories On Existing Switch Board Pg 6 Item 3.14 Group A 3.14.3 6 Amps 3 Way 5 Pin Socket, Supply And Fixing / Replacing Of 6 / 16 / 32 Amps Electrical Accessories On Existing Switch Board Pg 6 Item 3.14 Group A 3.14.4 6 Amps Three Pin Top, Supply And Fixing Of Bakelite D.P / Socket / Switch With / Without Neon Indicator Over Existing Wood Board Or Flush Mounting In Plastic / Nitches As Per Is 1293 And Is 3854 Pg 6 Item 3.14 Group A 3.14.3 32 Amps Flush / Projected Type Dp Switch, Supply And Fixing Of Bakelite D.P / Socket / Switch With / Without Neon Indicator Over Existing Wood Board Or Flush Mounting In Plastic / Nitches As Per Is 1293 And Is 3854 Pg6 Item 3.14 Group A 3.14.15 Electronic Stepped Regulator, Supply And Fixing Of Bakelite D.P / Socket / Switch With / Without Neon Indicator Over Existing Wood Board Or Flush Mounting In Plastic / Nitches As Per Is 1293 And Is 3854 Pg6 Item 3.14 Group A 3.14.12 16 Amps Three Pin Top, Supply And Fixing Of Bakelite D.P / Socket / Switch With / Without Neon Indicator Over Existing Wood Board Or Flush Mounting In Plastic / Nitches As Per Is 1293 And Is 3854 Pg6 Item 3.14 Group A 3.14.11 16 Amps Three Way 5 Pin Socket, Supply And Fixing Of Bakelite D.P / Socket / Switch With / Without Neon Indicator Over Existing Wood Board Or Flush Mounting In Plastic / Nitches As Per Is 1293 And Is 3854 Pg6 Item 3.14 Group A 3.14.10 16 Amps Two Way Switch, Supply And Fixing Of Bakelite D.P / Socket / Switch With / Without Neon Indicator Over Existing Wood Board Or Flush Mounting In Plastic / Nitches As Per Is 1293 And Is 3854 Pg6 Item 3.14 Group A 3.14.5 6 Amps Bakelite Ceiling Rose, Supply And Fixing Of Bakelite D.P / Socket / Switch With / Without Neon Indicator Over Existing Wood Board Or Flush Mounting In Plastic / Nitches As Per Is 1293 And Is 3854 Pg6 Item 3.14 Group A 3.14.6 6 Amps Lamp Holder, Supply And Fixing Of Bakelite D.P / Socket / Switch With / Without Neon Indicator Over Existing Wood Board Or Flush Mounting In Plastic / Nitches As Per Is 1293 And Is 3854 Pg6 Item 3.14 Group A 3.14.7 6 Amps Bell Push, Supply And Fixing Of Bakelite D.P / Socket / Switch With / Without Neon Indicator Over Existing Wood Board Or Flush Mounting In Plastic / Nitches As Per Is 1293 And Is 3854 Pg6 Item 3.14 Group A 3.14.7 6 Amps Bell Buzzer, Supplying 1 Way Plastic Gang Box And Fixing Using Necessary Wooden / Rawl / Phill Plugs And Screws Pg 6 / 3.12.1, Supplying 2 To 4 Way Plastic Gang Box And Fixing Using Necessary Wooden / Rawl / Phill Plugs And Screws Pg 6 / 3.12.2, Supplying 6 To 10 Way Plastic Gang Box And Fixing Using Necessary Wooden / Rawl / Phill Plugs And Screws Pg 6 / 3.12.2, Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg / 2.3.2 2.3.2 1.5 Sqmm, Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg / 2.3.3 2.3.3 2.5 Sqmm, Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 3 Item Sl No 2.3.4 2.3.4 4 Sqmm, Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 3 Item Sl No 2.3.5 2.3.5 6 Sqmm, Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 3 Item Sl No 2.3.6 2.3.6 10 Sqmm, Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 2.5.7 16 Sqmm, Kptcl Sr 22-23 Pg 16 / 27Ii Testing , Commissioning , Wiring , Identification & Termination Of Wires , Ferruling , Crimping & Termination Of Wires For Annunciation Etc, , , Testing Of Relays , Cts , Pts & Breakers For Operation Ii For Single 11 Kv Panel ( Indoor Type ) , Kptcl Sr 22-23 / Item 26Ci Testing & Commissioning Of C& R Panels , Wiring & Testing , Wiring Of C& R Panels , Identification , Ferruling , Crimping , Termination Of Wires In C & R Panels , Testing Of Relays , Control Operations For Closing , Tripping Etc.. Interlock Alarm Annunciation & Indication Checks, Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A 25 Sqmm Single Core, Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A 50 Sqmm Single Core, Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 100 Sqmm Single Run, Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100 V Gradw Multistrand Copper With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:1990 And Conforming To Gtp Of Group A Pg 6 Item Sl No 2.5 150 Sqmm Single Run, Supplying Capacitor Type Ceiling Fan Complete With Down Rod Blades, Shackle, Canopies Etc, For Operation On 230 V, 50 Cycles. Single Phase Ac Supply Conforming To Iss-374- 1979 And With Double Ball Bearing System. P22 / 6.3.1 6.3.1 48" Sweep ( 1200 Mm ) Regular Model, Supplying Capacitor Type Ceiling Fan Complete With Down Rod Blades, Shackle, Canopies Etc, For Operation On 230 V, 50 Cycles. Single Phase Ac Supply Conforming To Iss-374- 1979 And With Double Ball Bearing System. P 22 / 6.3.2 6.3.2 56" Sweep ( 1400 Mm ) Regular Model, Fixing A Ceiling Fan / Wall Monting Fan Of All Capacities And All Types With Necessary Clamps And S” Hook Made Out Of 15Mm Dia Ms Rod With 5 Amps Ceiling Rose Of Approved Quality With Necessary Length Of 23 / 0.0076” Inch Pvc Insulated Twin Twisted Wire Od Approved Quality . Mounted On A Suitable Size Wooden Board And Wired Pg 46 / 13.11 ( Sr 22-23 ) , Supplying Of 1440 Rpm Heavy Duty Exhaust Fan With Bracket Blades Suitable To Operate On 230 Volts 50 Hz Ac Supply Pg 22 / 6.2.1 6.2.1 12” Sweep ( 300Mm ) , Supplying Of 1440 Rpm Heavy Duty Exhaust Fan With Bracket Blades Suitable To Operate On 230 Volts 50 Hz Ac Supply Pg 22 / 6.2.1 6.2.2 15” Sweep ( 450Mm ) , Supplying Of Exhaust Fan With Bracket Blades Suitable To Operate On 230 Volts 50 Hz Ac Upply Pg 22 / 6.1, Supplying Of Pedestal Fan Suitable To Operate At Single Phase 230 Volts Ac Supply P26 / 6.33.1 6.33.1 400 Mm Sweep, Supplying Of Pedestal Fan Suitable To Operate At Single Phase 230 Volts Ac Supply P26 / 6.33.1 6.33.2 450 Mm Sweep, Supplying Wall Mounting Fan Suitable To Operate At Single Phase 230 Volts Ac Supply Pg 23 / 6.5.1 6.5.1 300Mm Sweep, Supplying Wall Mounting Fan Suitable To Operate At Single Phase 230 Volts Ac Supply Pg 23 / 6.5.1 6.5.2 400 Mm Sweep, Fabricating Supplying And Mounting Ms Box Made Out … Swg Suitable For Floor / Wall Mounting , Fully Weather Proof With Provision For Better Heat Dissipation , Provided With Hinged Front Cover , Equipped With Tamper Proof Locking Arrangements , With Suitable Size Clamps With Necessary Cable Entry Pipe With Gland And Box Should Be Finished With 2 Coats Of Red Oxide Primer Paint And Finally Finished With Approved Colour Enameled Metal Paint Etc.. Complete Pg 14 / 5.42 5.42.2 16 Swg, Supplying And Fixing Moulded Circuit Breaker ( Mccb ) Over Existing Wood Panel Board Using Necessary Screws, Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic / Micrpprocessed Release And Earth Fault As Per ( Is-13947 Pg 12 Item 5.14.7 Four Pole Four Pole 5.14.7 100 Amps 25 Ka, Supplying And Fixing Moulded Circuit Breaker ( Mccb ) Over Existing Wood Panel Board Using Necessary Screws, Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic / Micrpprocessed Release And Earth Fault As Per ( Is-13947 Pg 12 Item 5.14.8 Four Pole Four Pole Pwd Sr 22-23 5.14.8 125-160 Amps 25 Ka, Supplying And Fixing Moulded Circuit Breaker ( Mccb ) Over Existing Wood Panel Board Using Necessary Screws, Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic / Micrpprocessed Release And Earth Fault As Per ( Is-13947 Pg 12 Item 5.14.9 Four Pole Four Pole Pwd Sr 22-23 5.14.9 160 Amps 25 Ka, Supplying And Fixing Moulded Circuit Breaker ( Mccb ) Over Existing Wood Panel Board Using Necessary Screws, Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic / Micrpprocessed Release And Earth Fault As Per ( Is-13947 Pg 12 Item 5.14.10 Four Pole Four Pole Pwd Sr 2022To 2023 5.14.10 200 Amps 35 Ka, Supplying And Fixing Moulded Circuit Breaker ( Mccb ) Over Existing Wood Panel Board Using Necessary Screws, Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic / Micrpprocessed Release And Earth Fault As Per ( Is-13947 Pg 12 Item 5.14.11 Four Pole 5.14.11 250 Amps 35 Ka, Supplying And Fixing Moulded Circuit Breaker ( Mccb ) Over Existing Wood Panel Board Using Necessary Screws, Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic / Micrpprocessed Release And Earth Fault As Per ( Is-13947 Pg 12 Item 5.14.2 Four Pole 5.14.12 320-400 Amps 50 Ka, Supplying And Fixing Moulded Circuit Breaker ( Mccb ) Over Existing Wood Panel Board Using Necessary Screws, Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic / Micrpprocessed Release And Earth Fault As Per ( Is-13947 Pg 12 Item 5.14.13 Four Pole 5.14.13 400-500 Amps 50 Ka, Supplying And Fixing Moulded Circuit Breaker ( Mccb ) Over Existing Wood Panel Board Using Necessary Screws, Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic / Micrpprocessed Release And Earth Fault As Per ( Is-13947 Pg 12 Item 5.14.14 Four Pole 5.14.14 500-630 Amps 50 Ka, Supplying And Fixing Moulded Circuit Breaker ( Mccb ) Over Existing Wood Panel Board Using Necessary Screws, Bolts, Nuts And Wiring Complete .Protection Of Over Load And Short Circuit With Thermal Magnetic / Micrpprocessed Release And Earth Fault As Per ( Is-13947 Pg 12 Item 5.14.15 Four Pole 5.14.15 700-800 Amps 50 Ka, Supplying And Fixing Of Air Circuit Breakers 4Pole ( Acb.S ) Manual Operable Make :L&T, C&S . Schenider Or Abb, Supplying And Fixing Of 1 Od For Rmu ( Vcb, S ) 630 Amps , Bescom Sr 21-22 Pg 11 Item 39.05, Supplying And Fixing Of 1 Vl For Rmu, 630 Amps Bescom Sr 21-22 Pg 11 / 39.06, Bescom Sr 22-23 Pg 18 Item 58.04 Lt Metering Box For Housing The Etv Meter Without Cts Busbar Wiring Etc.. Bescom Sr 22-23 Pg 18 Item 58.04, Cleaning Of Ht Yard By Removing The Vegetation, Providing Painting For Ht Substation ( Alluminium Painting Including All Labour Charges, Providing Painting For 500 Kva Transformers, Providing Painting Of Lt Distribution Boards ( Spray Painting ) , Filtering Of Oil In The Transformer 500 Kva At The Transformer Centre By Hot Process Using Steam Line Filter “ Such Time The Dielectric Strength Of The Oil In The Transformer Conforms To Isi Specifications ( Test Certificates To Produced ) ( Each 500 Kva Transformer Approximately 380 Litres And Refilling May Be Required 30 To 50 Litres, Supplying And Filling Fresh Silica Gel To The Breathe Of The Transformers, Providing Alluminium Painting For The Structures & The Dg Set Exhaust Pipes 8 Inches For Height 30 Mtrs Including Materials And Labour Charges ( 4Nos ) , Filtering Of Oil In The Transformer 1000 Kva At The Transformer Centre By Hot Process Using Steam Line Filter “ Such Time The Dielectric Strength Of The Oil In The Transformer Conforms To Isi Specifications ( Test Certificates To Produced ) ( Each 500 Kva Transformer Approximately 380 Litres And Refilling May Be Required 30 To 50 Litres, Supplying And Filling Fresh Silica Gel To The Breathe Of The Transformers, Supplying And Fixing Of 25Mm Dia 2Mm Wall Thickness 15 Kv Class Alkathine Pipe To Bus Bar Leads Etc.. At Substation, Supplying And Topping Of Oil For Di-Electric Strength ( Bdv ) Acidity Transformer Oil As Per Is 335:1993 Bescom Sr 21-21 Pg 5 Item 15.01, Supplying And Filling Fresh Silica Gel To The Breathe Of The Transformers, Providing Megger Test For The Earth Pits At The Electrical Substation, Supplying And Fixing Of Nuts And Bolts For The Earth Pits At The Electrical Substation And Other Areas., Good Quality Well Burnt Out Charcoal For Grounding Purposes Packed In 30 Kgs Gunny Bag Bescom Sr 21-22 Sl No 440 Item 54.02, Good Quality Salt For Grounding Purposes Packed In 50 Kgs Gunny Bag Bescom Sr 21-22 Sl No 441 Item No: 54.03, Re- Construction Of Earth Pit Chambers , Labelling And Covering The Earth Pits With Cast Iron Cover 400X400x400 Mm, Providing Calibration Services For All The Energy Metres / Ct, S Of Dg Sets, Providing Megger Test Results For The Damaged Cables To Detect The Damage Of Lt Cable, Providing Megger Test Results For The Damaged Cables To Detect The Damage Of Ht Ug Cable, Submission Of Compliance Report To Electrical Inspectorate Against The Observations Made By The Electrical Inspectorate ( Except Statutory Fees ) , Providing Re- Winding For Copper Wound Transformer Including Releasing And Re-Fixing With All Lead And Lift Including Providing Crane Services And Providing Megger Test Etc.., Supplying Of 5 Hp Submersible Pump Motrs ( 2Nos ) Kirloskar Make / Atlanta / Texmo With A Delivery Point Is About 30 Mtrs Height For Dharmasahala Pump House Including Supplying And Fixing Automatic Starter Panel With Selctor Switch Type Change Over So That One Motor Shall Operate At A Time Including Supplying And Drawing 2 .5 Inch Cpvc Pipe , Automatic Starter Control Panel , Mccb 100 Amps And Mcb 3 Ploe 32 Amps And Contactor 40 Amps And Plumbimg Works Incuding Supplying And Fixing Of Non Return Vales 4Nos Of 50Mm And Gate Valves Of Heavy Duty 2Nos ) Of Required Size Etc.. With A Automatic Water Controller Facility By Supplying And Drawing Ofc Cable Of About 175 For Providing Water Supply To Ot Block, Providing Booster Pump For The Ro 500 Lph Plant Including Material And Labour Charges, Supplying Of 10 Hp Submersible Pump Motrs ( 2Nos ) Kirloskar Make / Atlanta / Texmo With Adelivery Point Is About 30 Mtrs Height For Dharmasahala Pump House Including Supplying And Fixing Automatic Starter Panel With Selctor Switch Type Change Over So That One Motor Shall Operate At A Time Including Supplying And Drawing 2 .5 Inch Cpvc Pipe , Automatic Starter Control Panel , Mccb 100 Amps And Mcb 3 Ploe 32 Amps And Contactor 40 Amps And Plumbimg Works Incuding Supplying And Fixing Of Non Return Vales 4Nos Of 65Mm And Gate Valves Of Heavy Duty 2Nos ) Of Required Size Etc.., Supplying Fixing And Wiring Earth Electrode For Grounding Of Lifts Transformers , Dg Sets Etc.. Using 40Mm Dia 2.9 Mm Thick 2.5 Mtr Long Gi Pipe With Gi Funnel With Mesh And Suitable Size Reducer Fixed On The Top Of The Earth Electrode .The Funnel Should Be Enclosed In A Cc Chamber Of 400X 400X 400Mm With A Cast Iron Cover .The Earth Electrode Shall Have Staggered Holes Of 12Mm Dia And The Electrode Should Be Covered 150Mm Alround With Alternate Layers Of Salt And Charcoal From The Bottom Of The Cc Chamber.The Connection From The Electrode Is To Be Established Through Gi Strip Using Gi Bolts And Nuts Pg 55 Item 7.2, Supplying And Running Of Gi / Copper Strips For Grounding Connections, Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Gi Strip 7.3.1 25 X3mm, Supplying And Running Of Gi / Copper Strips For Grounding Connections, Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Gi Strip 7.3.2 25 X6mm, Supplying And Running Of Gi / Copper Strips For Grounding Connections, Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Gi Strip 7.3.3 40 X6mm, Supplying And Running Of Gi / Copper Strips For Grounding Connections, Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Gi Strip 7.3.5 600X600x3mm Gi Plate, Supplying And Running Of Gi / Copper Strips For Grounding Connections, Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Copper Strip 7.3.6 25 X3mm, Supplying And Running Of Gi / Copper Strips For Grounding Connections, Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Copper Strip 7.3.7 25 X6mm, Supplying And Running Of Gi / Copper Strips For Grounding Connections, Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Copper Strip 7.933.8 40 X6mm, Supplying And Running Of Gi / Copper Strips For Grounding Connections, Using `1Necessary Fixing Materials As Required Pg 55 Item 7.3 Copper Strip 7.3.10 600X600x3mm Plate, Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 32.01 6 Sqmm, 2 Core ( 24 Gi Wire -1.4Mm ) , Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 23.02 10 Sqmm 2Core ( ( Gi Strips -4X0.8Mm ) , Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 32.03 10 Sqmm 4 Core ( 10 Gi Strips -4X0.8Mm ) , Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 32.05 16 Sqmm , 4 Core ( 11 Gi Strips -4X0.8Mm ) , Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 32.07 3.5 Core 25 Sqmm ( 12 Gi Strips -4X0.8Mm ) , Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A A Pg 9 / Item 32 Of Bescom Sr 21-22 32.09 3.5 Core 35 Sqmm, Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 32.11 3.5 Core 50 Sqmm, Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 32.12 4 Core 50 Sqmm, Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 32.13 70 Sqmm 3.5 Core, Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 32.14 95 Sqmm 3, 5 Core, Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 32.15 3.5 Core 120 Sqmm, Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 32.16 3.5 Core 150 Sqmm, Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A A Pg 9 / Item 32 Of Bescom Sr 21-22 32.17 3.5 Core 185 Sqmm, Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A A Pg 9 / Item 32 Of Bescom Sr 21-22 32.18 3.5 Core 240 Sqmm, Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvc Outer Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 32.19 3.5 Core 300 Sqmm, Supplying Of 1.1 Kv Lt Ug Cable Having Aluminium Conductor Pvc Insulated, Extruded Inner Sheathed Sheathed, Galvanised , Strips ( Except 2Cx10 Sqmm Wire Armoured ) Asper Is-3975:1990 & Extruded Pvcouter Sheathed Armoured Cable As Per Is-1554 Pare -1:1998 & Confirming To Gtp Of Group –A Pg 9 / Item 32 Of Bescom Sr 21-22 32.20 3.5 Core 400 Sqmm, Labour Charges For Laying Of Upto 95 Sqmm Lt Ug Cable Bescom Sr 21-22 Pg 4, Labour Charges For Laying Of 120 Sqmm Lt Ug Cable Bescom Sr 21-22 Pg 4, Labour Charges For Laying Of 150 Sqmm Lt Ug Cable Bescom Sr 21-22 Pg 4, Labour Charges For Laying Of 185 Sqmm Lt Ug Cable Bescom Sr 21-22 Pg 4, Labour Charges For Laying Of 240 Sqmm Lt Ug Cable Bescom Sr 21-22 Pg 4, Labour Charges For Laying Of 300 Sqmm Lt Ug Cable Bescom Sr 21-22 Pg 4, Labour Charges For Laying Of 400 Sqmm Lt Ug Cable Bescom Sr 21-22 Pg 4, Laying Of Cable In Existing Trench / Gi Pipe / Stone Ware / Rcc Hume Pipe Using Wooden / Aluminum Rollers As Directed By The Departmental Staff Lt Cable ( Page No. 09 Item No. 39 ) Bescom Sr Sl No. 230 ) 31.05 ) 2.5 To 25 Sqmm, Laying Of Cable In Existing Trench / Gi Pipe / Stone Ware / Rcc Hume Pipe Using Wooden / Aluminum Rollers As Directed By The Departmental Staff Lt Cable ( Page No. 09 Item No. 39 ) Bescom Sr Sl No. 231 ) 31.06 ) 35 To 95 Sqmm, Laying Of Cable In Existing Trench / Gi Pipe / Stone Ware / Rcc Hume Pipe Using Wooden / Aluminum Rollers As Directed By The Departmental Staff Lt Cable ( Page No. 09 Item No. 39 ) Bescom Sr Sl No. 231 ) 31.07 ) 120 To 240 Sqmm, Laying Of Cables In Existing Trench / Gi Pipe / Stone Ware / Rcc Hume Pipe Using Wooden / Alluminium Rollers As Directed By The Dept Staff Bescom Sr 21-22 Sl No: 225 Pg No 9 Item No: 31 31.01 3X95 Sqmm To 150 Sqmm, Laying Of Cables In Existing Trench / Gi Pipe / Stone Ware / Rcc Hume Pipe Using Wooden / Alluminium Rollers As Directed By The Dept Staff Bescom Sr 21-22 Sl No: 225 Pg No 9 Item No: 31 31.02 3X185 Sqmm To 240 Sqmm, Supplying And Drawing 3 Core Flat Pvc Sheathed Submersible Pump Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :13:8130-1984 And Virgin Grade Pvc Insulation And Powder Coating Pvc Extruded Pvc Sheathed Suitable For Working Voltage Up To 1100Volts As Per Is-694:2010 Pwd Sr 22-23 Pg 4 Item 2.5.2 2.5.2 3 Core X 1.5 Sqmm, Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin ) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 Pwd Sr 22-23 Pg 4 Item 2.5.2 2.5.3 4 Core X 1.5 Sqmm, Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin ) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694: 2.5.9 Pwd Sr 22-23 Pg 4 Item 2.5.9 2.5. 9 4 Core X 2.5 Sqmm, Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin ) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694: Pwd Sr 22-23 Pg 4 Item 2.5.16 2.5.16 4 Core X 4 Sqmm, Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin ) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is 694:1990 Pwd Sr 22-23 Pg 4 Item 2.5.16 2.5.11 6 Core X 1.5 Sqmm, Supplying And Drawing 3 Core Flat Pvc Sheathed Submersible Pump Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin ) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 Pwd Sr 22-23 Pg 4 Item 2.6.6 2.6.2 3Core 2.5 Sqmm, Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class Of Is :8310-1984 And ( Virgin ) Pvc Insulation And Sheathed Suitable Voltage Up To 1100Volts As Per Is -694:1990 & Conforming To Gtp Of Group-A Item 2.8 Pg No 8 2.6.3 3Core X 4Sq Mm, Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe / Stone Ware Pipe / On Wall / On Pole As Required Pwd Sr 19-20 Pg 41 Item 6.5.1 In Existing Trench / Duct 6.5.1 6 Sqmm To 16 Sqmm, Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe / Stone Ware Pipe / On Wall / On Pole As Required . Pwd Sr 19-20 Pg 41 Item 6.5.2 In Existing Trench / Duct 6.5.2 25 Sqmm To 75 Sqmm, Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe / Stone Ware Pipe / On Wall / On Pole As Required . Pwd Sr 19-20 Pg 41 Item 6.5.3 In Existing Trench / Duct6.5.3 95 Sqmm To 150 Sqmm, Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe / Stone Ware Pipe / On Wall / On Pole As Required. Pwd Sr 19-20 Pg 41 Item 6.5.4 In Existing Trench / Duct6.5.4 185 Sqmm To 240 Sqmm, Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe / Stone Ware Pipe / On Wall / On Pole As Required . Pwd Sr 19-20 Pg 41 Item 6.5.5 In Existing Trench / Duct 6.5.5 300 Sqmm To 400 Sqmm, Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trenchgi Pipe / Stone Ware Pipe / On Wall / On Pole As Required . Pwd Sr 19-20 Pg 41 Item 6.5.6 On Wall / Structure 6.5.6 6 Sqmm To 16 Sqmm, Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trenchgi Pipe / Stone Ware Pipe / On Wall / On Pole As Required . Pwd Sr 19-20 Pg 41 Item 6.5.7 On Wall / Structure 6.5.7 25 Sqmm To 75Sqmm, Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trenchgi Pipe / Stone Ware Pipe / On Wall / On Pole As Required. Pwd Sr 19-20 Pg 41 Item 6.5.8 On Wall / Structure 6.5.8 95 Sqmm To 150Sqmm, Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trenchgi Pipe / Stone Ware Pipe / On Wall / On Pole As Required . Pwd Sr 19-20 Pg 41 Item 6.5.9 On Wall / Structure 6.5.9 185 Sqmm To 240 Sqmm, Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trenchgi Pipe / Stone Ware Pipe / On Wall / On Pole As Required . Pwd Sr 19-20 Pg 41 Item 6.5.10 On Wall / Structure 6.5.10 300 Sqmm To 400 Sqmm, Earth Work Excavation For Cable Trench Of 0.5 To 0.75 Mtr Width And Depth Upto 1 Mtr Including Trial Pits , Depositing On Bank Upto A Lead 50 Mtrs, Supplying And Displaying Necessary Danger Boards And Lighting, Using Sight Rails And Sign Boards At Every 100 Mtrs Wherever Necessary As Directed ( Bescom Sr 21-22 Pg 8 Item 29.02 ( Added 30 % Special Locality Allowance ) 29.02 In Ordinary Soil, Earth Work Excavation For Cable Trench Of 0.5 To 0.75 Mtr Width And Depth Upto 1 Mtr Including Trial Pits , Depositing On Bank Upto A Lead 50 Mtrs, Supplying And Displaying Necessary Danger Boards And Lighting, Using Sight Rails And Sign Boards At Every 100 Mtrs Wherever Necessary As Directed ( Bescom Sr 21-22 Pg 8 Item 29.03 ( Added 30 % Special Locality Allowance ) 29.03 In Hard Soil, Earth Work Excavation For Cable Trench Of 0.5 To 0.75 Mtr Width And Depth Upto 1 Mtr Including Trial Pits , Depositing On Bank Upto A Lead 50 Mtrs, Supplying And Displaying Necessary Danger Boards And Lighting, Using Sight Rails And Sign Boards At Every 100 Mtrs Wherever Necessary As Directed ( Bescom Sr ) In Hard Rock / Latterite Rock, Latterite Soil, Refilling The Trenches With Selected Available Earth From The Trenchexcavation Including Watering, Consolidation In Layers Of 15Cmthickness Including Deposition Of Surplus Earth With Lead Of 200 Mtrs ( Bescom Sr ) Pg 8 / 29.07, Cutting The Road Surface For Cable Trenches And Disposing Of The Excavated Earth, As Directed Including Barricading, Danger Lighting Then Refilling The Cable Trenches ( Bescom Sr ) Pg 8 / 29.09 Macadam Road, Cutting The Road Surface For Cable Trenches And Disposing Of The Excavated Earth, As Directed Including Barricading, Danger Lighting Then Refilling The Cable Trenches ( Bescom Sr ) Tar Road Pg 8 / 29.10, Cutting The Road Surface For Cable Trenches And Disposing Of The Excavated Earth, As Directed Including Barricading, Danger Lighting Then Refilling The Cable Trenches ( Bescom Sr ) Cement Concrete Road, Ksrb 4-1.3 Providing And Laying In Position Plain Cement Concrete Of Mix 1:4:8 With Opc Cement @ 180Kgs, With 40Mm And Down Size Graded Metal Coarse Aggregate @0.85Cum And Fine Aggregates @0.57Cum Machine Mixed, Concrete Laid In Layers Not Exceeding 15Cms. Thick Well Compacted In Foundation Including Cost Of All Materials, Labour Hom Of Machinery Curing Complete As Per Specifications Kbs 4.1 , 4.2 ( Bescom Sr 22-23 ) Pg 9 / 33.08, Ksrb 4-1.3: Providing And Laying In Position Plane Cement Concrete Of Mix1:2:4 With Cement @240Kgs With 20Mm And Down Size Graded Granite Metal Coarse Aggregates @ 0.878Cmt And Fine Aggregates @ 0.459 Cmt Machine Moixed Concrete Laid In Layers Not Exceeding 15 Cm, Thick Well Compacted , In Foundation And Plinth And Cills Including Coost Of All Materials , Labour , Hom Of Machinery, Curing Complete As Per Specifications , Specification No Kbs 4.1 4.2 Bescom Sr 22-23 Pg 9 / 33.09, Providing Painting Two Coats For The Lt Distribution Panel Boards Including Cleaning Inside The Entire Panel Bard And Including One Coat Of Primer As Per The Directions Of The Engineer-In- Charge And The Existing Color Only Including Fixing Of Danger Boards, Spreading Of 40Mm Stone Jelly Including Materials And Labour Charges, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Sr 19-20 Item 6.17.3 4 Sqmm, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Sr 19-20 Item 6.17.4 6Sqmm, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Sr 19-20 Item 6.17.5 6.17.5 10 Sqmm, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Sr 19-20 Item 6.17.6 6.17.6 16 Sqmm, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Sr 19-20 Item 6.17.7 6.17.7 25 Sqmm Long Barrel, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Sr 19-20 Item 6.17.8 6.17.8 35 Sqmm Long Barrele, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Sr 19-20 Item 6.17.9 6.17.9 50 Sqmm Long Barrel, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Sr 19-20 Item 6.17.10 6.17.10 70 Sqmm Long Barrel, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Sr 19-20 Item 6.17.11 6.17.11 95 Sqmm Long Barrel, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Sr 19-20Item 6.17.12 6.17.12 120 Sqmm Long Barrel, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Item 6.17.13 6.17.13 150 Sqmm Long Barrel, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Item 6.17.14 185 Sqmm Long Barrel, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Item 6.17.15 240 Sqmm Long Barrel, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Sr 19-20 Item 6.17.16 300 Sqmm Long Barrel, Supplying Tinned Copper Lugs And Crimping And Wiring To Terminal Point Of Wire Of The Following Sizes Pg 43 Sr 19-20 Item 6.17.17 6.17.17 400 Sqmm Long Barrel, Supplying And Running Gi / Copper Conductor For Grounding And ( Along With Other Wires In Conduit System Of Wiring ) Using Necessary Suitable Clamps , Nails , Guttas / Spacers Etc.. Pg 43 Sr 19-20 Item 6.18.3 8 Swg Gi Wire, Fixing A Ceiling / Wall Mounting Fan Of All Capacities And All Types To The Existing Shook With Fan Regulator To The Existing Board Together With Supplying And Fixing A 5 Amperes Ceiling Rose , Necessary Length Of 23 / 0.0076” Inch Pvc Insulated Twin Twisted Copper Wire And Wiring Pg 48 Item13.10 Pwd Sr 22-23, Extra Length Of Gi Pipe Of Class B 19Mm Dia For Down Rod Pg 46 Item 13.12, Fixing A Ceiling / Wall Mounting Fan Of All Capacities And All Types With Necessary Clamps And “ S “ Hook Made Out Of 15Mm Dia Ms Rod , With 5 Amps Ceiling Rose Of Approved Quality With Necessary Length Of 23 / 0.0076 Inch Pvc Insulated Twin Twisted Wire Of Approved Quality. Mounted On Suitable Size And Wired Pg 48 Item 13.11 Pwd Sr 22-23, Supplying Exhaust Fan Of 1440 Rpm Of 300Mm ( 12’ ) Heavy Duty Exhaust Fan With Bracket Blades Suitable To Operate On 230 Volts 50 Hz Ac Supply Complete Pg 22 Sr 22-23 Item 6.2.1 6.2.1 12” Sweep ( 300Mm ) , Supplying Exhaust Fan Of 1440 Rpm Of 300Mm ( 12’ ) Heavy Duty Exhaust Fan With Bracket Blades Suitable To Operate On 230 Volts 50 Hz Ac Supply Complete Pg 22 Sr 22-23 Item 6.2.2 6.2.2 15” Sweep ( 450Mm ) , Fixing One Exhaust Fan After Making A Suitable Nitch In The Wall And Finishing With Cement Morter And Colouring To Match The Existing Wall Or Brackets With Bolts And Nuts And A 5 Amps Ceiling Rose With Sufficient Length Of 23 / 0.0076 Inch Pvc Insulated Twin Core Wire Of Approved Make With Wire Mesh Amd Wooden Frame Pg 46 Item 13.13, Fixing All Types And All Capacities Of 1X4’ / 2’X2’ Led Light Fittings On The Wall / Ceiling / Rafters / Girders With Necessary Supporting Frame , Using 23 / 0.0076 Inch Twin Twisted Pvc Insulated Wires , Required Nos Of Round Block Pg 47 / 13.19 Pwd Sr 22-23, Supplying Of 2 Tr Capacity Window Type Air Conditioner Conforming To Is Specifications , Suitable For Operation On 230 Volts , 50 Hz Single Phase Ac Supply With All Accessories . Pg 23 / 6.6.3 6.6.3 2 Tr Capacity 5 Star Rated Make : Blue Star / Diakin / Mitsubhishi, Supplying Of 5 Star 1 Ton Capacity Split Type Air Conditioner Confirming To Is Specification Suitable For Operation On 230 Volts , 50 Hz Ac Supply With All Accessories Pg 24 Item 6.8.4 Sr 22-23 6.8.4 1 Ton Capacity 5 Star Rated Invertor Make : Blue Star / Diakin / Mitsubhishi, Supplying Of 5 Star 1 Ton Capacity Window Type Air Conditioner Confirming To Is Specification Suitable For Operation On 230 Volts , 50 Hz Ac Supply With All Accessories Pg 24 Item 6.8.5 Sr 22-23 6.8.5 1.5 Ton Capacity 5 Star Rated Invertor Make : Blue Star / Diakin / Mitsubhishi, Supplying Of 5 Star Rated 2 Tr Split Air Conditioner Suitable For Operation On Ac Supply Single Phase 50 Hz 230 Volts With Hermitically Sealed Compressor With Air Cooled Condenser, Motor Capacitor And Start Run Capacitors, Relay And Over Load Protector Internal Unit. With One Indoor And One Out Door Unit .The Condenser Unit Will Be Placed Outside The Room On The Terrace To Avoid The Noise Including Standard Length Of Suitable Size Copper Tubing Covered With Insulation Tube . ( High Wall Chorded / Chordless ) Pg 24 Item 6.8.6 Sr 22-23 6.8.6 2 Ton Capacity 5 Star Rated Make : Blue Star / Diakin / Mitsubhishi, Supply Erection, Testing, Commissioning Of Cassette Type Split Air Conditioners Suitable For Operation On Single / Three Phase Ac Supply, Hermetically Sealed Compressor With Air Cooled Condenser Motor Capacitor Start, Capacitors Run Relay And Over Load Protection, One Ceiling Mounted Indoor Unit And One Outdoor Condenser Unit Including Standard Accessories Covered With Insulation Tube Including Battery Operated Cordless Unit Pg 24 / Item 6.9.3 Sr 22-23 6.9.3 2 Tr Cassette Single Phase Make : Blue Star / Diakin / Mitsubhishi, Supply Erection, Testing, Commissioning Of Cassette Type Split Air Conditioners Suitable For Operation On Single / Three Phase Ac Supply, Hermetically Sealed Compressor With Air Cooled Condenser Motor Capacitor Start, Capacitors Run Relay And Over Load Protection, One Ceiling Mounted Indoor Unit And One Outdoor Condenser Unit Including Standard Accessories Covered With Insulation Tube Including Battery Operated Cordless Unit Pg 24 / Item 6.9.4 Sr 22-23 6.9.4 3 Tr Cassette Three Phase Make : Blue Star / Diakin / Mitsubhishi, Supply Erection, Testing, Commissioning Of Cassette Type Split Air Conditioners Suitable For Operation On Single / Three Phase Ac Supply, Hermetically Sealed Compressor With Air Cooled Condenser Motor Capacitor Start, Capacitors Run Relay And Over Load Protection, One Ceiling Mounted Indoor Unit And One Outdoor Condenser Unit Including Standard Accessories Covered With Insulation Tube Including Battery Operated Cordless Unit Pg 24 / Item 6.9.5 Sr 22-23 6.9.5 4 Tr Cassette Three Phase Make : Blue Star / Diakin / Mitsubhishi, Installation Charges For 1 To 2Ton Capacity Window Type Air Conditioners With 50X75 Thick Teak Wood Frame Of Suitable Size And Allied Works Complete Pg 24 Item 6.12 Sr 22-23, Installation Charges For Split Type Air Conditioners With Allied Works For One Indoor And One Outdoor Unit Is To Be Mounted On Suitable Angle Iron Support Upto 3.0 Ton Split / Cassette Type A / C Pg 24 Item 6.12 Sr 22-23, Supplying And Fixing Of Insulated Refrigrent Copper Tubing Of 5 / 8’’ And 3 / 8’’ With Polythene Foam Insulation 3 Core 80 Strands Copper Wiring Between Indoor And Outdoor Unit.Leak Testing Of Oil And Gas Charging For Additional Piping Length Of Tube Pg 25 Item 6.13.1 Sr 22-23 6.13.1 Split, Supplying And Fixing Of Insulated Refrigrent Copper Tubing Of 5 / 8’’ And 3 / 8’’ With Polythene Foam Insulation 3 Core 80 Strands Copper Wiring Between Indoor And Outdoor Unit.Leak Testing Of Oil And Gas Charging For Additional Piping Length Of Tube Pg 25 Item 6.13.1 Sr 22-23 6.13.2 Cassette, Supplying And Refilling Refrigerant ( F-22 / F-12 ) For Air Conditioning Equipment Including Labour And Nitrogen Gas For Pressure And Leak Testing Pg 80 Item 9.17, Supplying And Refilling Refrigerant ( R-32 / R-410A ) For Air Conditioning Equipment Including Labour And Nitrogen Gas For Pressure And Leak Testing, Extra For Fabrication Supply And Fixing Of Standard Fabricated Using Slotted Angel / L-Angel Of Size 6Mmx50mm For Mounting Out Door / Indoor A.C.Unit / Batteries Pg 25 Item 6.22 Sr 22-23, Supplying And Fixing Capacitors Of Approved Make For Window / Split Air Conditioners Pg 25 Item 6.16.1 6.16.1 25 To 45 Mfd Running Capacitor Sr 22-23, Supplying And Fixing Capacitors Of Approved Make For Window / Split Air Conditioners Pg 80 Item 9.14 6.16.2 80 To 200 Mfd Starting Capacitor Sr 22-23, Supplying And Installation , Testing And Commissioning Of Heavy Duty Compressor Suitable Foe Window / Split Type Ac Pg 25 Item 6.14.1 Sr 22-23 6.14.1 1 Ton Capacity, Supplying And Installation , Testing And Commissioning Of Heavy Duty Compressor Suitable For Window / Split Type Ac Pg 25 Item 6.14.2 Sr 22-23 6.14.2 1.5 To 2Ton Capacity, Supplying And Installation , Testing And Commissioning Of Heavy Duty Compressor Suitable Foe Window / Split Type Ac Pg 25 Item 6.14.3 Sr 22-23 6.14.3 3 Ton Capacity, Supply And Fixing Of In Door Unit Complete With Condensing Coil, Blower, Fan Etc., Complete Suitable For Split Air Conditioners. Pg 26 / Item 6.43.1 6.34.1 1 Ton Capacity, Supply And Fixing Of In Door Unit Complete With Condensing Coil, Blower, Fan Etc., Complete Suitable For Split Air Conditioners Pg26 / Item 6.34.2 6.34.2 1.5 Ton Capacity No New Item 22209.00, Supply And Fixing Of In Door Unit Complete With Condensing Coil, Blower, Fan Etc., Complete Suitable For Split Air Conditioners Pg 26 / Item 6.34.3 6.34.3 2 Ton Capacity, Supply And Fixing Of Out Door Condensing Unit Complete With Condensing Coil, Blower, Fan Etc., Complete Suitable For Split Air Conditioners Pg 25 / Item 6.23.1 6.23.1 1 Ton Capacity, Supply And Fixing Of Out Door Condensing Unit Complete With Condensing Coil, Blower, Fan Etc., Complete Suitable For Split Air Conditioners Pg 25 / Item 6.23.2 6.23.2 1.5 Ton Capacity, Supply And Fixing Of Out Door Condensing Unit Complete With Condensing Coil, Blower, Fan Etc., Complete Suitable For Split Air Conditioners Pg 25 / Item 6.23.2 6.23.3 2 Ton Capacity, Supplying And Drawing Of 5 / 8” And 7 / 8” Hard Drawn Refrigerant Pipe And Insulation Suitable For 11Tr Ductable Split Air Conditioner Pg 25 / 6.24, Providing Cleaning For The Gi Ducting Line Along With Flanges , Supports & All Fixing Materials Once In A Month Including Labour Charges, Providing Cleaning For Inside And Outside The 60 / 80 Kva Ups / Amf Panel Ups At Least Once In A Three Months By Using Blower / Vaccum Cleaner, Supplying And Commisioning Of Ac Remote For Cassette / Package Type Ductable, Supply Of Led Streetlight Luminaire With Pressure Die Cast Aluminium Housing Body For Optimal Thermal Dissipation. Lamp Compartment Comprising Of Anti Glare Clear Diffuser With Injection Moulded Polycarbonate Material, Delivering Superior Light Output Rated Life Burning Hrs 50000 Hr @ Lumen Maintenance Of 70%, Maximum Light Intensity Should Be Between 60 Degrees To 70 Degrees. Cct ≫ 5500K, Ip66 Optical And Electrical Compartment & Impact Resistance Of Complete Luminaire ≫ Ik08. Power Factor ≫0.9 With Mains, Surge Protection- Min 5Kv Along With Over Voltage / Overload, Short Circuit / Miss-Wiring Protection. Compatible For Pole Mounting With Outer Dia Of 40Mm To 50Mm. Universal Voltage Driver To Operate Wide Voltage Range From 100V To 270V 50 / 60Hz Application. Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80 Adherence With Rohs. Ul Approved Mcpcb. Top Access Street Light With Single Screw To Ensure Ease Of Maintenance At The Sight Site Location With Minimized Minimal Tools. Led Light Fixture With ........W System Power Consumption. Led Efficiency≫1301M / W, Nominal Cri ≫75. Luminaire Manufacturer Should Have In-House Facility Accredited By Nabl / Cpri & Any Government Certified Agency & Design & Development Facility Certified By Iso 9001:2008. Housing With Supplier Word Mark / Name Shall Be Engraved / Embossing On The Die Cast Housing / Body Part. Warranty Of 2 Years Against Any Manufacturing Defect Working Under Standard Electrical Conditions As Mentioned Pg 36 / 11.8.5 11.8.5 Led Street Lights 120 Watts, Supply Of Led Streetlight Luminaire With Pressure Die Cast Aluminium Housing Body For Optimal Thermal Dissipation. Lamp Compartment Comprising Of Anti Glare Clear Diffuser With Injection Moulded Polycarbonate Material, Delivering Superior Light Output Rated Life Burning Hrs 50000 Hr @ Lumen Maintenance Of 70%, Maximum Light Intensity Should Be Between 60 Degrees To 70 Degrees. Cct ≫ 5500K, Ip66 Optical And Electrical Compartment & Impact Resistance Of Complete Luminaire ≫ Ik08. Power Factor ≫0.9 With Mains, Surge Protection- Min 5Kv Along With Over Voltage / Overload, Short Circuit / Miss-Wiring Protection. Compatible For Pole Mounting With Outer Dia Of 40Mm To 50Mm. Universal Voltage Driver To Operate Wide Voltage Range From 100V To 270V 50 / 60Hz Application. Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80 Adherence With Rohs. Ul Approved Mcpcb. Top Access Street Light With Single Screw To Ensure Ease Of Maintenance At The Sight Site Location With Minimized Minimal Tools. Led Light Fixture With ........W System Power Consumption. Led Efficiency≫1301M / W, Nominal Cri ≫75. Luminaire Manufacturer Should Have In-House Facility Accredited By Nabl / Cpri & Any Government Certified Agency & Design & Development Facility Certified By Iso 9001:2008. Housing With Supplier Word Mark / Name Shall Be Engraved / Embossing On The Die Cast Housing / Body Part. Warranty Of 2 Years Against Any Manufacturing Defect Working Under Standard Electrical Conditions As Mentioned Pg 36 / 11.8.6 11.8.6 Led Street Lights 150 Watts, Supply Of Led Streetlight Luminaire With Pressure Die Cast Aluminium Housing Body For Optimal Thermal Dissipation. Lamp Compartment Comprising Of Anti Glare Clear Diffuser With Injection Moulded Polycarbonate Material, Delivering Superior Light Output Rated Life Burning Hrs 50000 Hr @ Lumen Maintenance Of 70%, Maximum Light Intensity Should Be Between 60 Degrees To 70 Degrees. Cct ≫ 5500K, Ip66 Optical And Electrical Compartment & Impact Resistance Of Complete Luminaire ≫ Ik08. Power Factor ≫0.9 With Mains, Surge Protection- Min 5Kv Along With Over Voltage / Overload, Short Circuit / Miss-Wiring Protection. Compatible For Pole Mounting With Outer Dia Of 40Mm To 50Mm. Universal Voltage Driver To Operate Wide Voltage Range From 100V To 270V 50 / 60Hz Application. Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80 Adherence With Rohs. Ul Approved Mcpcb. Top Access Street Light With Single Screw To Ensure Ease Of Maintenance At The Sight Site Location With Minimized Minimal Tools. Led Light Fixture With ........W System Power Consumption. Led Efficiency≫1301M / W, Nominal Cri ≫75. Luminaire Manufacturer Should Have In-House Facility Accredited By Nabl / Cpri & Any Government Certified Agency & Design & Development Facility Certified By Iso 9001:2008. Housing With Supplier Word Mark / Name Shall Be Engraved / Embossing On The Die Cast Housing / Body Part. Warranty Of 2 Years Against Any Manufacturing Defect Working Under Standard Electrical Conditions As Mentioned Pg 36 Item 11.8.8 11.8.8 Led Street Lights 200 Watts, Supplying And Fixing Of........Mm Dia Class A Gi Pipe Bracket Upto 2 Mtrs Long Bent At Suitable Angle And Fixing To This Bracket 1X40 / 2X40 W Fluorescent Tube Street Light Fitting Of All Capacities To Gi Or Gi Or Rail Or Rcc Pole / Wall Using Suitable Cla, Bolts, And Nuts And Wiring Using Suitable Capacity Wires. Pg 45. / 13.1.1 13.1.1 Using 25Mm Dia Gi Pipe, Supplying And Fixing........Mm Dia Class A Gi Pipe Bracket Upto 2.7 Meters Long Terminated With A Reducing Collar Of 40X25mm To Which Extra Pipe Of 175Mm Length Is Fixed For Fixing Mv / Sv / Mh / Ftl Street Light Fitting Of All Capacities On Rail / Rcc / Wall / Tubular Pole, Using Suitable Cla, Bolts, Nuts And Wiring Using Suitable Capacity Wires. Pg 45 / 13.2.1 13.2.1 Using 25Mm Dia Gi Pipe, Supplying And Fixing........Mm Dia Class A Gi Pipe Bracket Upto 2.7 Meters Long Terminated With A Reducing Collar Of 40X25mm To Which Extra Pipe Of 175Mm Length Is Fixed For Fixing Mv / Sv / Mh / Ftl Street Light Fitting Of All Capacities On Rail / Rcc / Wall / Tubular Pole, Using Suitable Cla, Bolts, Nuts And Wiring Using Suitable Capacity Wires. Pg 45 / 13.2.2 13.2.2 Using 32Mm Dia Gi Pipe, Fixing All Types And All Capacities Of 1X4 / 2X2 Led Light Fittings Indoor On The Wall / Ceiling / Rafters / Girders With Necessary Supporting Frame, Using 2310.0076" Twin Twisted Pvc Insulated Wires, Required Nos Of Round Blocks And Clamps Pg 6 / 13.19, Fixing Of ..... A Tpst / Change Over Switch / Contactor Along With Neutral Link With Screws, Bolts, Nuts And Wiring Using Required Capacity Wires And Circuit Labeling Pg 46 / Item 13.18.6 300 Amps To 400 Amps, Supplying & Fixing Led Drivers Suitable For 5700K Led Fitting Indoor Fixtures. Operating Voltage Range From 180V To 265V, 50Hz Ac Power Supply Pg 43 / 12.51.7 12.51.7 36W 5700K Suitable For Indoor Led Fitting, Supplying & Fixing Led Drivers Suitable For 5700K Led Fitting Indoor Fixtures. Operating Voltage Range From 180V To 265V, 50Hz Ac Power Supply Pg 43 / 12.51.4 12.51.4 15W To 18W 5700K Suitable For Indoor Led Fitting, Supplying & Fixing Led Drivers Suitable For 5700K Led Fitting Outdoor Fixtures. Operating Voltage Range From 180V To 265V, 50Hz Ac Power Supply Pg 43 / 12.52.6 12.52.6 150W 5700K Suitable For Outdoor Led Fitting, Supplying & Fixing Led Drivers Suitable For 5700K Led Fitting Outdoor Fixtures. Operating Voltage Range From 180V To 265V, 50Hz Ac Power Supply Pg 43 / 12.52.2 12.52.2 40W 5700K Suitable For Outdoor Led Fitting., Supplying & Fixing Led Drivers Suitable For 5700K Led Fitting Outdoor Fixtures. Operating Voltage Range From 180V To 265V, 50Hz Ac Power Supply Pg 43 / 12.52.4 12.52.4 90 Watts 5700K Suitable For Out Door Fitting, Releasing The Existing Fan Dismantling Testing Painting After Removing The Existing Painting By Scraping And Cleaning ( Spray Method ) Not Less Than 2 Coats Of Approved Make Enamel Paint To A Ceiling Fan And Wiring And Fixing Of The Same Pg 39 / 12.5, Supplying And Replacing Ceiling Fan Regulator 900Mm To 1500Mm. Pg 39 / 12.6 Each 172.00 189.00, Releasing The Existing Fan Checking, Testing And Installation At The Same Place. Pg 39 / Item 12.9, Releasing The Existing Ftl Fitting All Capacities, Checking, Testing And Installing At Same Place Pg 39 / 12.11, Fixing Halogen / Metal Halide / Svl / Il / Led Floodlight Fitting Over Existing Pole / Wall Ceiling Including Cla, Bolts, Nuts And Wiring Using Suitable Capacity Wires. Pg 45 / 13.5, Fixing All Types And All Capacities Of Fluorescent / False Ceiling / Spot Light / Cfl / Led Fittings Indoor On The Wall / Ceiling / Rafters / Girders Using 23 / 0.0076" Twin Twisted Pvc Insulated Wires, Required Nos Of Round Blocks And Clamps Pg 45 / 13.7.1 13.7.1 On Wall / Ceiling / Rafter / Girders, Supplying & Fixing Of Retrofit Type - Led Bulb ...... W With Opal Acrylic Diffuser Comprising Of Led Source With Cct 6500 Degree K, Cri≫ 70%. Efficacy ≫80 Lumen Per W, Life≫ 25000 Burning Hours And Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80. The Led Are Driven By Hf Electronic Driver Integrated In The System, With Pf ≫ 0.95, Power Loss Should ≪ 5% Of Lamp Wage., Short Circuit & Open Circuit Protection To Be Integrated In The Circuit, Thd Less Than 20%, Life As Per Lm 79. The Operating Input Voltage Should Be Between 130 To 275 V. Bis Approved And Tested By Nabl / Cpri Accredited Laboratory With 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition Pg 39 / 11.11.1 11.11.1 3 Watts 6500K, Supplying & Fixing Of Retrofit Type - Led Bulb ...... W With Opal Acrylic Diffuser Comprising Of Led Source With Cct 6500 Degree K, Cri≫ 70%. Efficacy ≫80 Lumen Per W, Life≫ 25000 Burning Hours And Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80. The Led Are Driven By Hf Electronic Driver Integrated In The System, With Pf ≫ 0.95, Power Loss Should ≪ 5% Of Lamp Wage., Short Circuit & Open Circuit Protection To Be Integrated In The Circuit, Thd Less Than 20%, Life As Per Lm 79. The Operating Input Voltage Should Be Between 130 To 275 V. Bis Approved And Tested By Nabl / Cpri Accredited Laboratory With 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition Pg 39 / 11.11.6 11.11.6 15 Watts 6500K, Supplying & Fixing Of Retrofit Type - Led Bulb ...... W With Opal Acrylic Diffuser Comprising Of Led Source With Cct 6500 Degree K, Cri≫ 70%. Efficacy ≫80 Lumen Per W, Life≫ 25000 Burning Hours And Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80. The Led Are Driven By Hf Electronic Driver Integrated In The System, With Pf ≫ 0.95, Power Loss Should ≪ 5% Of Lamp Wage., Short Circuit & Open Circuit Protection To Be Integrated In The Circuit, Thd Less Than 20%, Life As Per Lm 79. The Operating Input Voltage Should Be Between 130 To 275 V. Bis Approved And Tested By Nabl / Cpri Accredited Laboratory With 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition Pg 39 / 11.11.3 11.11.3 7 Watts 6500K, Supplying & Fixing - Flexible Led Strip Light ..... W Power Consumption In 5 Ms Length Cct6500 Degree K, Cri≫ 70%. Efficacy ≫80 Lumen Per W, Life≫ 25000 Burning Hours And Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80. The Led Are Driven By Hf Electronic Driver Non Integrated, With Pf ≫ 0.95, Power Loss Should≪ 5% Of Lamp Wage., Short Circuit & Open Circuit Protection To Be Integrated In The Circuit, Thd Less Than 20%, Life As Per Lm 79. The Operating Input Voltage Should Be Between 130 To 275 V. Bis Approved With 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition. Pg 33 / 11.1, Supplying Of .....Feet -Pvc Batten With Integrated Led Tube .... W With High Quality Diffuser With Life Of 25000 Burning Hours & 70% Lumen Maintenance With Cri ≫ 80. Power Input: 220-240V@ 50 / 60Hz & Power Factor ≫0.9 Along With Ce Approved. 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition Pg 34 / 11.3.1 Led Light Fitting 1X2’-9 / 10 Watts, Supplying Of .....Feet -Pvc Batten With Integrated Led Tube .... W With High Quality Diffuser With Life Of 25000 Burning Hours & 70% Lumen Maintenance With Cri ≫ 80. Power Input: 220-240V@ 50 / 60Hz & Power Factor ≫0.9 Along With Ce Approved. 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition Pg 34 / 11.3.2 11.3.2 Led Light Fitting 1X4’-20 / 22 Watts, Supplying Of .....Feet -Pvc Batten With Integrated Led Tube .... W With High Quality Diffuser With Life Of 25000 Burning Hours & 70% Lumen Maintenance With Cri ≫ 80. Power Input: 220-240V@ 50 / 60Hz & Power Factor ≫0.9 Along With Ce Approved. 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition Pg 34 / 11.3.3 11.3.3 Led Light Fitting 1X4’-36 / 40 Watts, Supplying Of Recess Mounting Non Integrated Type Led Down Light...... W Luminaire Comprising Of Pressure Decast / Extruded Aluminium Housing, With Spring Loaded False Ceiling Cla, Led Of Power / Cob With Cct 6500 Degree K, Cri≫ 70%. Efficacy ≫100 Lumen Per W, 120Degree Beam Spread, Life≫ 25000 Burning Hours And Compliance To Is10322 / Iec 60598, Lm 79 & Lm 80. The Lamp Compartment Is Enclosed With Anti Glare Opal Diffuser Which Enhances The Lighting Level. Leds Are Driven By Hf Electronic Driver Integrated In A Separate Control Gear Assembly., With Pf ≫ 0.95, Power Loss Should≪ 5% Of Lamp Wage, Short Circuit & Open Circuit Protection To Be Integrated In The Circuit, Thd Less Than 20%, Life As Per Lm 79. The Operating Input Voltage Should Be Between 130 To 275 V. Bis Approved And Tested By Nabl / Cpri Accredited Laboratory With 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition. Pg 34 / 11.4.2 11.4.2 10-12 Watts, Supplying Of Recess Mounting Non Integrated Type Led Down Light...... W Luminaire Comprising Of Pressure Decast / Extruded Aluminium Housing, With Spring Loaded False Ceiling Cla, Led Of Power / Cob With Cct 6500 Degree K, Cri≫ 70%. Efficacy ≫100 Lumen Per W, 120Degree Beam Spread, Life≫ 25000 Burning Hours And Compliance To Is10322 / Iec 60598, Lm 79 & Lm 80. The Lamp Compartment Is Enclosed With Anti Glare Opal Diffuser Which Enhances The Lighting Level. Leds Are Driven By Hf Electronic Driver Integrated In A Separate Control Gear Assembly., With Pf ≫ 0.95, Power Loss Should≪ 5% Of Lamp Wage, Short Circuit & Open Circuit Protection To Be Integrated In The Circuit, Thd Less Than 20%, Life As Per Lm 79. The Operating Input Voltage Should Be Between 130 To 275 V. Bis Approved And Tested By Nabl / Cpri Accredited Laboratory With 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition Pg 34 / 11.4.3 11.4.3 15-18 Watts, Supplying Of Recess Mounting Non Integral Type ........ Led W Luminaire Comprising Of Pressure Decast / Extruded Aluminium Housing, With Spring Loaded False Ceiling Cla, Power Leds With Cct 6500 Degree K, Cri≫ 70%. Efficacy ≫ 100 Lumen Per W, 120Degree Beam Spread, Life≫ 25000 Burning Hours And Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80. The Lamp Compartment Is Enclosed With Anti Glare Opal Diffuser Which Enhances The Lighting Level Leds Are Driven By Hf Electronic Driver Integrated In A Separate Control Gear Assembly., With Pf ≫ 0.95, Power Loss Should≪ 5% Of Lamp Wage., Short Circuit & Open Circuit Protection To Be Integrated In The Circuit, Thd Less Than 20%, Life As Per Lm 79. The Operating Input Voltage Should Be Between 130 To 275 V. Bis Approved And Tested By Nabl / Cpri Accredited Laboratory With 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition. Pg 32 / 11.6 11.6.1 Led Modular Down Light 1X1 34-22 W, Supplying Of Recess Mounting Non Integral Type ........ Led W Luminaire Comprising Of Pressure Decast / Extruded Aluminium Housing, With Spring Loaded False Ceiling Cla, Power Leds With Cct 6500 Degree K, Cri≫ 70%. Efficacy ≫ 100 Lumen Per W, 120Degree Beam Spread, Life≫ 25000 Burning Hours And Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80. The Lamp Compartment Is Enclosed With Anti Glare Opal Diffuser Which Enhances The Lighting Level Leds Are Driven By Hf Electronic Driver Integrated In A Separate Control Gear Assembly., With Pf ≫ 0.95, Power Loss Should≪ 5% Of Lamp Wage., Short Circuit & Open Circuit Protection To Be Integrated In The Circuit, Thd Less Than 20%, Life As Per Lm 79. The Operating Input Voltage Should Be Between 130 To 275 V. Bis Approved And Tested By Nabl / Cpri Accredited Laboratory With 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition. Pg 32 / 11.6.2 11.6.2 Led Modular Down Light 2X2 / 1X4 34-36 Watts, Supplying ...Litres Capacity Vertical / Horizontal Type Wall Mounting Electrical Water Heater With 22 Swg Copper / Ss Sheet Metal Inner Container Tinned Inside Fiber Body Outside, Filled With Glass Wool Between Inner And Outer Container For Thermal Insulation Complete. The Inlet And Outlet Pipes So Arranged That Water Flow Inside Results In Water To Flow Out From The Inner Container Without Turbulence. The Inner Container Shall Have Direct Immersion Type Copper Tube Nickel Plate. 2Kw Capacity Element With A Neon Indicator Fitted With 20A Capacity 25 To 85 Degree Centigrade Range Thermostat. The Water Heater Shall Completely Be Wired With 40 / 0.0076 Inch 3 Core Copper Flexible Wire Of 1.5 Meters Length And The Outer Container Provided With Heavy Gauge Brackets For Wall Mounting. 5 Star With Fibre Body Pg 27 / Item 7.2.1 7.2.1 25 Litres 5 Star With Fibre Body, Supplying ...Litres Capacity Vertical / Horizontal Type Wall Mounting Electrical Water Heater With 22 Swg Copper / Ss Sheet Metal Inner Container Tinned Inside Fiber Body Outside, Filled With Glass Wool Between Inner And Outer Container For Thermal Insulation Complete. The Inlet And Outlet Pipes So Arranged That Water Flow Inside Results In Water To Flow Out From The Inner Container Without Turbulence. The Inner Container Shall Have Direct Immersion Type Copper Tube Nickel Plate. 2Kw Capacity Element With A Neon Indicator Fitted With 20A Capacity 25 To 85 Degree Centigrade Range Thermostat. The Water Heater Shall Completely Be Wired With 40 / 0.0076 Inch 3 Core Copper Flexible Wire Of 1.5 Meters Length And The Outer Container Provided With Heavy Gauge Brackets For Wall Mounting. 5 Star With Fibre Body Pg 27 / Item 7.2.3 7.2.3 50 Litres 5 Star Rated With Fibre Body, Erection Charges For Fixing A Upto 30 Litres Capacity Wall Mounting Electric Geysers Using Bolts, Flat At One End Nut And Washers At The Other End For Through Bolts And Nuts And Washers With 150X450x600mm Back Plate And Wiring Complete With 15A 3 Pin Top Pg 46 / 13.15.1 13.15.1 Upto 30 Litres, Erection Charges For Fixing A 35 Litres To 50 Litres Capacity Wall Mounting Electric Geysers Using Bolts, Flat At One End Nut And Washers At The Other End For Through Bolts And Nuts And Washers With 150X450x600mm Back Plate And Wiring Complete With 15A 3 Pin Top Pg 46 / 13.15.2 13.15.2 35 Litres To 50 Litres, Supplying, Installation, Testing & Commissioning Of 12V ..Ah Batteries In Poly Propylene Container For D.G. Sets. Low Maintenance Batteries, Plate Type Pg 29 / 9.4.4 9.4.4 100 Ah Capacity, Supplying, Installation, Testing & Commissioning Of 12V ..Ah Batteries In Poly Propylene Container For D.G. Sets. Low Maintenance Batteries, Plate Type Pg 29 / 9.4.6 9.4.6 150 Ah Capacity, Supplying, Installation, Testing & Commissioning Of 12V ..Ah Batteries In Poly Propylene Container For D.G. Sets. Low Maintenance Batteries, Plate Type Pg 29 / 9.4.7 9.4.7 200 Ah Capacity, Supplying, Installation, Testing & Commissioning Of 12V ..Ah Batteries In Poly Propylene Container For D.G. Sets. Low Maintenance Batteries, Plate Type Pg 29 / 9.4.1 9.4.1 40 Ah Capacity, Supplying, Installation, Testing & Commissioning Of 12V ..Ah Batteries In Poly Propylene Container For D.G. Sets. Low Maintenance Batteries, Plate Type Pg 29 / 9.4.2 9.4.2 60 Ah Capacity, Supplying, Installation, Testing & Commissioning Of 12V Dc, Ah Batteries In Poly Propylene Container For U.P.S. Sealed Maintenance Free Batteries Pg 29 / 9.5.1 9.5.1 7 Ah Capacity Sealed Maintenance Free Batteries, Supplying, Installation, Testing & Commissioning Of 12V Dc, Ah Batteries In Poly Propylene Container For U.P.S. Sealed Maintenance Free Batteries Pg 29 / 9.5.2 9.5.2 18 Ah Capacity Sealed Maintenance Free Batteries, Supplying, Installation, Testing & Commissioning Of 12V Dc, Ah Batteries In Poly Propylene Container For U.P.S. Sealed Maintenance Free Batteries Pg 29 / 9.5.3 9.5.3 26 Ah Capacity Sealed Maintenance Free Batteries, Supplying, Installation, Testing & Commissioning Of 12V Dc, Ah Batteries In Poly Propylene Container For U.P.S. Sealed Maintenance Free Batteries Pg 29 / 9.5.4 9.5.4 42 Ah Capacity Sealed Maintenance Free Batteries, Supplying, Installation, Testing & Commissioning Of 12V Dc, Ah Batteries In Poly Propylene Container For U.P.S. Sealed Maintenance Free Batteries Pg 29 / 9.5.5 9.5.5 60 / 65 Ah Capacity Sealed Maintenance Free Batteries, Supplying, Installation, Testing & Commissioning Of 12V Dc, Ah Batteries In Poly Propylene Container For U.P.S. Sealed Maintenance Free Batteries Pg 29 / 9.5.6 9.5.6 75 / 80 Ah Capacity Sealed Maintenance Free Batteries, Supplying, Installation, Testing & Commissioning Of 12V Dc, Ah Batteries In Poly Propylene Container For U.P.S. Sealed Maintenance Free Batteries Pg 29 / 9.5.7 9.5.7 100 Ah Capacity Sealed Maintenance Free Batteries, Supplying, Installation, Testing & Commissioning Of 12V Dc, Ah Batteries In Poly Propylene Container For U.P.S. Sealed Maintenance Free Batteries Pg 29 / 9.5.8 9.5.8 120 Ah Capacity Sealed Maintenance Free Batteries, Supplying, Installation, Testing & Commissioning Of 12V Dc, Ah Batteries In Poly Propylene Container For U.P.S. Sealed Maintenance Free Batteries Pg 29 / 9.5.8 9.5.9 150 Ah Capacity Sealed Maintenance Free Batteries, Supplying, Installation, Testing & Commissioning Of 12V Dc, Ah Batteries In Poly Propylene Container For U.P.S. Sealed Maintenance Free Batteries Pg 29 / 9.5.8 9.5.10 200 Ah Capacity Sealed Maintenance Free Batteries, Supplying And Installation Of Battery To Battery Connecting Cable 10 Sqmm Copper Cable Cotton Insulation On Top Including Crimping Of Copper Lugs, Supplying And Installation Of Battery To Battery Connecting Cable 25 Sqmm Copper Cable Cotton Insulation On Top Including Crimping Of Copper Lugs, Supplying And Installation Of Battery To Battery Connecting Cable 35 Sqmm Copper Cable Cotton Insulation On Top Including Crimping Of Copper Lugs, Supplying And Installation Of Battery To Battery Connecting Cable 50 Sqmm Copper Cable Cotton Insulation On Top Including Crimping Of Copper Lugs, Heavy Duty Battery To Battery Jumper Cable 25 Sqmm , Red / Black Exterior For Quick Identification , Flexible Cables, 20 Feet In Length, Carrying Case Included, Heavy Duty Tight Grip Alligator Clamps Strong Spring And Comfortable Handle For Easy Positioning, Supplying, Erecting, Testing & Commissioning Of On-Line Ups System Suitable For Operation On 230V, 50Hz, A / C Supply, With Isolation Transformer All Accessories Complete And Excluding Batteries And Wiring Complete Pg 29 / 9.3.1 9.3.1 9.3.1 1 Kva On Line Ups Make :Apc, Supplying, Erecting, Testing & Commissioning Of On-Line Ups System Suitable For Operation On 230V, 50Hz, A / C Supply, With Isolation Transformer All Accessories Complete And Excluding Batteries And Wiring Complete. Pg 29 / 9.3.2 9.3.2 3 Kva On-Line Ups, Supplying, Erecting, Testing & Commissioning Of On-Line Ups System Suitable For Operation On 230V, 50Hz, A / C Supply, With Isolation Transformer All Accessories Complete And Excluding Batteries And Wiring Complete Pg 29 / 9.3.3 9.3.3 5 Kva On-Line Ups, Supplying, Erecting, Testing & Commissioning Of Off- Line Ups System Suitable For Operation On 230V, 50Hz, A / C Supply, With All Accessories Complete And Excluding Batteries And Wiring Complete. Pg 29 / 9.2.1 9.2.1 1 Kva Off Line Ups, Supplying Push Button Operated Direct Online Starter With An Antiweld Silver Cadmium Oxide Contactor With Replaceable Fixed And Moving Contacts And Bimetallic Thermal Overload Relay Help In Anticorrosion Treated Sheet Steel Or Iron Clad Enclosure And Fixing The Same To Suitable Capacity Wires For 230 / 440 V 1 / 3 Phase Motor Upto 5 Hp Pg 10 / 5.1, Supplying Fully Automatic Star-Delta Starter Unit Push Button Type With Suitable Wires, 3 Contactors, One Adjustable Thermal Timer Mounted On A Common Base Plate Held In Steel Enclosure For Use On 400 / 440 V 3 Phase And Wired After Fixing To The Existing Wooden Board For Motor Pg 10 / 5.2 Upto 12.5 Hp, Supply And Fixing Of 4Pole Power Contactor With No / Nc Contacts On Existing Wood / Panel Board Using Necessary Bolts, Nuts, Washers And Wiring Etc., Complete With Ac-3 Rating And As Per Is-13947 Pg 10 / 5.13.11 5.13.11 400 Amps Four Pole, Supply And Fixing Of 4Pole Power Contactor With No / Nc Contacts On Existing Wood / Panel Board Using Necessary Bolts, Nuts, Washers And Wiring Etc., Complete With Ac-3 Rating And As Per Is-13947 Pg 10 / 5.13.11 5.13.15 800 Amps Four Pole, Supplying And Fixing Regular Mccb Distribution Panel Confirming To Is / Iec 61439 - 3 And Ik09 Tested As Per Is / Iec 62262 With Minimum Ip43 Protection Provided With Polyurethane ( Pur ) Gasket, With Suitable Earthing System, On Wall / Wood Board / Flush Mounting Using Required Cl A , Bolts, Nuts, Etc., With Provision For Fixing Of Suitable Type Capacity Mccbs As An Incomer For 3 Phase Double Door With Necessary Bus Bar Completely Wired To Use On 440V 3Phase 4 Wire Powder Coated Painting Etc., Complete With A Provision For Fixing Of Single / Three Phase Suitable Capacity Mcbs As Outgoings Confirming To Is / Iec 60898 Pg 12 / 5.16.1 5.16.1 4 Way, Supplying And Fixing Regular Mccb Distribution Panel Confirming To Is / Iec 61439 - 3 And Ik09 Tested As Per Is / Iec 62262 With Minimum Ip43 Protection Provided With Polyurethane ( Pur ) Gasket, With Suitable Earthing System, On Wall / Wood Board / Flush Mounting Using Required Cl A , Bolts, Nuts, Etc., With Provision For Fixing Of Suitable Type Capacity Mccbs As An Incomer For 3 Phase Double Door With Necessary Bus Bar Completely Wired To Use On 440V 3Phase 4 Wire Powder Coated Painting Etc., Complete With A Provision For Fixing Of Single / Three Phase Suitable Capacity Mcbs As Outgoings Confirming To Is / Iec 60898 Pg 12 / 5.16.2 5.16.2 8 Way, Supplying And Fixing Regular Mccb Distribution Panel Confirming To Is / Iec 61439 - 3 And Ik09 Tested As Per Is / Iec 62262 With Minimum Ip43 Protection Provided With Polyurethane ( Pur ) Gasket, With Suitable Earthing System, On Wall / Wood Board / Flush Mounting Using Required Cl A , Bolts, Nuts, Etc., With Provision For Fixing Of Suitable Type Capacity Mccbs As An Incomer For 3 Phase Double Door With Necessary Bus Bar Completely Wired To Use On 440V 3Phase 4 Wire Powder Coated Painting Etc., Complete With A Provision For Fixing Of Single / Three Phase Suitable Capacity Mcbs As Outgoings Confirming To Is / Iec 60898 Pg 12 / 5.16.3 5.16.3 12 Way, Supplying & Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 13 / 5.17.1 5.17.1 6-32 Amps Sp, Supplying & Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 13 / 5.17.2 5.17.2 40 Amps Sp, Supplying & Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 13 / 5.17.3 5.17.3 50-60 Amps Sp, Supplying & Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 13 / 5.17.4 5.17.4 6-32 Amps Dp, Supplying & Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 13 / 5.17.5 5.17.5 40 Amps Dp, Supplying & Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 13 / 5.17.6 5.17.6 50-60 Amps Dp, Supplying & Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 13 / 5.17.7 5.17.7 5-32 Amps Tp&N, Supplying & Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 13 / 5.17.8 5.17.8 40 Amps Tp&N, Supplying & Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898 Pg 13 / 5.17.8 5.17.9 50-63 Amps Tp&N, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.1 5.18.1 4 Way Sp&N Single Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.2 5.18.2 6 Way Sp&N Single Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.3 5.18.3 8 Way Sp&N Single Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.4 5.18.4 12 Way Sp&N Single Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.5 5.18.5 16 Way Sp&N Single Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.6 5.18.6 4 Way Sp & N Double Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.7 5.18.7 6 Way Sp&N Double Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.8 5.18.8 8 Way Sp&N Double Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.9 5.18.9 12 Way Sp&N Double Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.10 5.18.10 16 Way Sp&N Double Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.11 5.18.11 4 Way Tp&N Double Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.12 5.18.12 8 Way Tp&N Double Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.13 5.18.13 12 Way Tp&N Double Door, Supplying And Fixing Regular Mcb Distribution Boards On Wall / Ood Board / Flush Mounting Using Required Clamps , Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting Made Out Of 14 Swg Ms Enclosure. Pg 13 / 5.18.14 5.18.14 16 Way Tp&N Double Door, Supplying, And Fixing Of Hot Dip Galvanized M.S.Bracket Suitable For Out Door Luminaries And Mounted On Octagonal Pole Using Necessary Bolts, Nuts Etc., Complete. Pg 9 / 4.7.1 4.7.1 Single Arm Bracket With 1000 Mm Standard 40 / 50 Mm Dia, Supplying Of On Load Change Over Switches 4 Poles, Ac23a Duty, 415V, 50Hz, Ac Supply. With All Accessories. ( Sm Enclosure Sheet Metal Execution ) Pg 11 / 5.12.6 5.12.6 400 Amps 4 Pole, Supplying Of On Load Change Over Switches 4 Poles, Ac23a Duty, 415V, 50Hz, Ac Supply. With All Accessories. ( Sm Enclosure Sheet Metal Execution ) Pg 11 / 5.12.7 5.12.7 630 Amps 4 Pole, Supplying Of On Load Change Over Switches 4 Poles, Ac23a Duty, 415V, 50Hz, Ac Supply. With All Accessories. ( Sm Enclosure Sheet Metal Execution ) Pg 11 / 5.12.8 5.12.8 800 Amps 4 Pole, Networking & Telecomunication Supplying And Drawing Utp-Cat 6E Lan Cable Pg 27 / 8.1, Supplying And Drawing Pvc Flexible One Pair Telephone Unarmoured Tinned Copper Cable. Pg 27 / 8.2.1 8.2.1 1 Pair, Supplying And Drawing Pvc Flexible One Pair Telephone Unarmoured Tinned Copper Cable. Pg 27 / 8.2.2 8.2.2 2 Pair, Supplying And Drawing Pvc Flexible One Pair Telephone Unarmoured Tinned Copper Cable. Pg 27 / 8.2.3 8.2.3 3 Pair, 3 Supplying And Drawing Pvc Insulated Gas Injected Physical Foam Jelly Flooded Co-Axial Tv Cable.Rg-6 Pg 28 / 8.3, Supplying & Fixing Of Switch Mounting Rack With Power Manager & Cable Manager Pg 28 / 8.4.1 8.4.1 4U With 450Mm Depth, Supplying & Fixing Of Switch Mounting Rack With Power Manager & Cable Manager Pg 28 / 8.4.2 8.4.2 6U With 450Mm Depth, Supplying & Fixing Of Switch Mounting Rack With Power Manager & Cable Manager Pg 28 / 8.4.3 8.4.3 9U With 450Mm Depth, Supplying & Fixing Of Switch Mounting Rack With Power Manager & Cable Manager Pg 28 / 8.4.4 8.4.4 12U With 450Mm Depth, Supplying & Fixing Of Switch Mounting Rack With Power Manager & Cable Manager Pg 28 / 8.4.5 8.4.5 18U With 650Mm Depth, Supplying & Fixing Of Power Strip Pg 28 / 8.5, Supplying Of Shelf Pg 28 / 8.6, Supplying & Fixing Of Castor Wheels To The Shelf ( Set Of 4 ) Pg 28 / 8.7, Supplying & Fixing Of Fan Pg 28 / Item 8.8, Supplying Fixing Of Network Switches Pg 28 / 8.9.18.9.1 48 Port Gigabyte ( Manageable ) , Supplying Fixing Of Network Switches Pg 28 / 8.9.2 8.9.2 24 Port Gigabyte ( Manageable ) , Supplying Fixing Of Network Switches Pg 28 / 8.9.3 8.9.3 10 Port Gigabyte ( Manageable, Supplying Fixing Of Network Switches Pg 28 / 8.9.4 8.9.4 48 Port 10 / 100 Switch 8.9.5 24 Port 10 / 100 Switch, Supplying Fixing Of Network Switches Pg 28 / 8.9.5 24 Port 10 / 100 Switch, Supplying Fixing Of Network Switches Pg 28 / 8.9.6 8.9.6 16 Port 10 / 100 Switch, Supplying Fixing Of Network Switches Pg 28 / 8.9.7 8.9.7 8 Port 10 / 100 Switch, Supplying Fixing Of Network Switches Pg 28 / 8.9.7 8.9.8 5 Port 10 / 100 Switch, Supplying Fixing Of Network Switches Pg 28 / 8.9.7 8.9.9 48 Port 10 / 100 / 1000 Switch, Supplying Fixing Of Network Switches Pg 28 / 8.9.10 8.9.10 24 Port 10 / 100 / 1000 Switch, Supplying Fixing Of Network Switches Pg 28 / 8.9.10 8.9.11 16 Port 10 / 100 / 1000 Switch, Supplying Fixing Of Network Switches Pg 28 / 8.9.10 8.9.12 8 Port 10 / 100 / 1000 Switch, Supplying & Fixing Of I / O Socket With Back Box Pg 28 / 8.10.1 8.10.1 Single I / O Pg 28 / 8.10.1, Supplying & Fixing Of I / O Socket With Back Box Pg 28 / 8.10.2 8.10.2 Double I / O, Supplying & Fixing Of ... Ms Cat 6 Patch Cable Pg 28 / 8.11.1 1 Meter, Supplying & Fixing Of ... Ms Cat 6 Patch Cable Pg 28 / 8.11.2 2 Meter, Supplying & Fixing Of ... Ms Cat 6 Patch Cable Pg 28 / 8.11.3 3Meter, Supplying & Fixing Of Patch Panel For Lan Cabling Pg 28 / 8.12.1 48 Port 10 / 100 Patch Panel, Supplying & Fixing Of Patch Panel For Lan Cabling Pg 28 / 8.12.2 24 Port 10 / 100 Patch Panel, Supplying & Fixing Of Patch Panel For Lan Cabling Pg 28 / 8.12.3 16 Port 10 / 100 Patch Panel, Supplying & Fixing Of Patch Panel For Lan Cabling Pg 28 / 8.12.4 8.12.4 48 Port 10 / 100 / 1000 Patch Panel, Supplying & Fixing Of Patch Panel For Lan Cabling Pg 28 / 8.12.5 8.12.5 24 Port 10 / 100 / 1000 Patch Panel, Supplying & Fixing Of Patch Panel For Lan Cabling Pg 28 / 8.12.5 8.12.6 16 Port 10 / 100 / 1000 Patch Panel, Providing, Supplying To Work Site, Single Phase Submersible Pump Sets Of 100Mm Dia ( 4 Inch ) Suitable For Bore Well Confirming To Is 8034-2000 Specifications, With Testing Of As Per Instructions Of Engineer Incharge Of Work And Latest Amendments 5.00 Hp / 3.7Kw 50 Stg P100d [ Bwsb Sr 2021-22, P.No.166 I.No:10.4 ] , Providing, Supplying To Work Site, Submersible Pump Set Of 150Mm Dia Suitable For Bore Well And Confirming To Is 8034-2000;3Phase, Ss Bowl & Impeller With Low Volt Motor As Per Specifications , As Per Necessary Ammendments And Instructions Of Engineer Incharge Of Work. 10.00 Hp - 90 Lpm @ 220 M = 20 Stg Outlet Dia - 2.00” [ Bwsb Sr 2021-22, P.No.168 I.No:16.7 ] , Supply And Delivery At Site Of Brand New Best Make Non-Return Valve As Per Is 778 / 1984 With Isi Mark And As Per Its Latest Amendments P260a Size 50 Mm [ Bwsb Sr 2021-22, P.No.170 I.No:28.1 ] , Supply And Delivery At Site Brand New Best Make Pvc Insulated Cable Of Flat 3 Core ( Sheathed ) Of Nominal Cross Sectional Area As Per Is 694-1990 With Isi Mark And As Per Its Latest Amendments.1X3x6 Sqm.P230d [ Bwsb Sr 2021-22, P.No.169 I.No:22.4 ] , Supply And Delivery Of Galvanized Mild Steel Tubes Of 6Mtr Standard Length Heavy Duty ( C Class ) As Per Is 1239 ( Part-I ) 1990 With Latest Amendments With Isi Mark ( One End Fitted With Heavy Duty Collar And Other End Fitted With Protective Cover ) 50 Mm P310a [ Bwsb Sr 2021-22, P.No.170 I.No:33.1 ] , Providing, Supplying And Fixing Suitable For 1.1 Kv Class Ug Cable Filled With Necessary Bitumen, Labour Charges For Providing Connection Using Insulated Sheathed Steel Wire Cable As Per Is 1554 / 1988 With Latest Amendments From Kptcl Pole To Meter Board Unit, With All Necessary Materials , Tools And Equipments, As Per Specifications With Testing Of As Per Instructions Of The Engineer In- Charge Of The Work Pg 164 / 44 Bwssb Sr 21-22 41.1 3.5 Core X6 Sqmm, Labour Charges For Providing Connection Using Insulated Sheathed Steel Wire Cable As Per Is 1554 / 1988 With Latest Amendments From Kptcl Pole To Meter Board Unit, With All Necessary Materials, Tool And Equipments, As Per Specifications With Testing Of As Per Instructions Of Engineer Incharge Of Work. . Pg 164 / 44 Bwssb Sr 21-22 41.2 3.5 Core X10 Sqmm, Labour Charges For Providing Connection Using Insulated Sheathed Steel Wire Cable As Per Is 1554 / 1988 With Latest Amendments From Kptcl Pole To Meter Board Unit, With All Necessary Materials And Tools And Equipments, As Per Specificationswith Testing Of As Per Instructions Of Engineer Incharge Of Work. . Pg 164 / 44 Bwssb Sr 21-22 41.3 3.5 Core X25 Sqmm, Supply And Delivery Of Centrifugal Pump Set At Site Brand New Best Make And With Discharge Duty Conforming To Isi Standards And Its Latest Amendments Pg 164 / 46.1 Bwssb Sr -21-22 Item 46.1 46.1 2 Hp Size 65X650 Head 13 M , Discharge 462 Lpm, Supply And Delivery Of Centrifugal Pump Set At Site Brand New Best Make And With Discharge Duty Conforming To Isi Standards And Its Latest Amendments Pg 164 / 46.1 Bwssb Sr -21-22 Item 46.3 46.3 3 Hp Size 50X40 Head 30 M , Discharge 198 Lpm, Supply And Delivery Of Centrifugal Pump Set At Site Brand New Best Make And With Discharge Duty Conforming To Isi Standards And Its Latest Amendments Pg 164 / 46.1 Bwssb Sr -21-22 Item 46.3 46.4 5 Hp Size 80X65 Head 23.50M, Discharge 600 Lpm, Supply And Delivery Of Centrifugal Pump Set At Site Brand New Best Make And With Discharge Duty Conforming To Isi Standards And Its Latest Amendments Pg 164 / 46.1 Bwssb Sr -21-22 Item 46.3 46.4 5 Hp Size 80X65 Head 46 M, Discharge 174 Lpm, Supply And Delivery Of Centrifugal Pump Set At Site Brand New Best Make And With Discharge Duty Conforming To Isi Standards And Its Latest Amendments Pg 164 / 46.1 Bwssb Sr -21-22 Item 46.3 46.9 10 Hp Size 80X65 Head 34.50 Discharge 840 Lpm, Earthing: Supplying And Fixing And Wiring Earth Electrode Forgroundingcircuits Ic Cutouts And Other Equipments On The Meter Board In The Pit. The Pits Should Be Filled Up With Equal Proportion Of Salt Andcharcoal150mm Around The Pipe To Complete Depth. The Connection From The Pipeto The Conduits Etc. Is To Established Through Gi Wire Of Sizes As Per Clause7.3.3 Of Is 72 Using 12Mm Bolts, Nuts, Washers And Checknuts, The Pipe Shall Have 16 Through Holes Of 12Mm Dia Pg 164 / 45 Bwssb Sr 21-22, Supply And Delivery At Site Brand New Best Make Starter / Control Panel Suitable For Following Hp Centrifugal Pump Conforming With Isi Mark And Its Latest Amendments Pg 165 / Item 49 Bwssb Sr 21-22 49.1 Upto 7.5 Hp Centrifugal Pump, Supply And Delivery At Site Brand New Best Make Starter / Control Panel Suitable For Following Hp Centrifugal Pump Conforming With Isi Mark And Its Latest Amendments Pg 165 / Item 49 Bwssb Sr 21-22 49.2 7.5 To 10 H.P Centrifugal Pump, Supplying And Fixing Of Led Type Panel Board Indicating Lamp With Required Colour Suitable For 230 / 440 Volt Ac , 50 Hz 12 / 24 Volt Dc Pg 14 / 5.38 Pwd Sr 22-23, Supplying, Fixing And Wiring 50 / 5 To 400 / 5A, 5Va Burden Current Transformer Class 0.5 Accuracy With Tape Around Pwd Sr 22-23 Pg 14 Item 5.34, Supplying, Fixing And Wiring 1000 / 5 To1600 / 5A, 15Va Burden Class 1 Current Transformer Pwd Sr 22-23 Pg 14 Item 5.36, Supplying And Fixing Lt Ug Cable Of Size 4X25sqmm Suitable For Centrifugal Pump Set With Isi Mark And Its Latest Amendments Pg 165 / Item 52 Bwssb Sr 21-22, Re- Winding Of Monoblock Motor With Copper Insulation Wire Suitable Gauge As Per Isi Specifications With All Necessary Materials And Labour Charges , Tools And Equipments With Guarantee Period Of Not Less Than 12 Months Pg 165 / Item 55 55.1 Upto 7.5 Hp Monoblock Motor Rewinding, Re- Winding Of Monoblock Motor With Copper Insulation Wire Suitable Gauge As Per Isi Specifications With All Necessary Materials And Labour Charges , Tools And Equipments With Guarantee Period Of Not Less Than 12 Months Pg 165 / Item 55 55.2 10 Hp Monoblock Motor Rewinding, Supplying Ball Bearing As Per Isi Specification With Guarantee Period Of Not Less Than 12 Months Pg 165 / 166 Item 56 56.1 Bearing Cost For 5 Hp, Supplying Ball Bearing As Per Isi Specification With Guarantee Period Of Not Less Than 12 Months Pg 165 / 166 Item 56 56.2 Bearing Cost For 10 Hp, Labour Charges For Erection, Electrification And Commissioning Of Pump Sets, Including Aligning And Balancing Of All Items Including Supply And Erection Of Two Pair Of Supporting Clamps, Bore Well Caps, Cable Clips And Water Tight Gland Cable Protectors, Bolts, Nuts, Valve And Gauges, Tools And Equipments Etc., Involved In The Job As Per Specifications, With Necessary Tests As Per Specifications, With Testing Of As Per Instructions Of Engineer Incharge Pg 163 Item 38 Bwssb Sr 21-22, Labour Charges For Erection Of Indoor Type Panel Board And Meter Board Units With All Necessary Materials And Labour Tools And Equipments Including Cement Concrete For Foundation / Bed Etc, Complete As Per Specification, With Testing Of As Per Instructions Of Engineer Incharge Of Work. N Pg 163 / Item 39 Bwssb Sr 21-22, Labour Charges For Providing Connection Using Insulated Sheathed Steel Wire Cable As Per Is 1554 / 1988 With Latest Amendments From Kptcl Pole To Meter Board Unit, With All Necessary Materials , Tools And Equipments, As Per Specificationswith Testing Of As Per Instructions Of Engineer Incharge Of Work Pg 163 Item 41 Bwssb Sr 21-22 41.1 3.5 Core X6 Sqmm, Labour Charges For Providing Connection Using Insulated Sheathed Steel Wire Cable As Per Is 1554 / 1988 With Latest Amendments From Kptcl Pole To Meter Board Unit, With All Necessary Materials , Tools And Equipments, As Per Specificationswith Testing Of As Per Instructions Of Engineer Incharge Of Work Pg 163 Item 41 Bwssb Sr 21-22 41.2 3.5 Core X10 Sqmm, Labour Charges For Providing Connection Using Insulated Sheathed Steel Wire Cable As Per Is 1554 / 1988 With Latest Amendments From Kptcl Pole To Meter Board Unit, With All Necessary Materials , Tools And Equipments, As Per Specificationswith Testing Of As Per Instructions Of Engineer Incharge Of Work Pg 163 Item 41 Bwssb Sr 21-22 41.6 3.5 Core X16 Sqmm, Supply And Delivery At Site 50Mm ( 2” ) Dia Heavy Duty Unplasticised Pvc Column Pipes With Heavy Duty Collars , Rubber Profile Ring , Vibration Controil Profile Ring, Freezing And Turbulence Free Leak Proof Epdm Ring With Isi Mark With Latest Amendments Pg 163 / Item 34 Bwssb Sr 21-22, Supply And Delivery At Site Accessories For Single Phase Pump Set Like Ss Groove Nipples, Ss Studs & Nuts , Screw Clips & Water Proof Insulation Tape Etc.. Complete With Isi Mark Pg 163 Item 26 Bwssb Sr 21-22, Providing Main Connection From Pole Pvc Insulated Sheathed Steel Wire Cable In New Trench As Per Is 1554 / 1988 With Latest Amendments With Isi Mark From Kptcl Pole To Meter Board Pg 163 / Item 42 Bwssb Sr 21-22, Supply And Delivery At Site Brand New Best Make Pvc Insulated Cable Of Flat 3 Core ( Sheathed ) Of Nominal Cross Sectional Area As Per Is 694-1990 With Isi Mark And As Per Its Latest Amendments Pg 161 / 22 Bwssb Sr 21-22 22.2 1X3x2.5 Sqmm, Supply And Delivery At Site Brand New Best Make Pvc Insulated Cable Of Flat 3 Core ( Sheathed ) Of Nominal Cross Sectional Area As Per Is 694-1990 With Isi Mark And As Per Its Latest Amendments Pg 161 / 22 Bwssb Sr 21-22 22.3 1X3x4 Sqmm, Supply And Delivery At Site Brand New Best Make Pvc Insulated Cable Of Flat 3 Core ( Sheathed ) Of Nominal Cross Sectional Area As Per Is 694-1990 With Isi Mark And As Per Its Latest Amendments Pg 161 / 22 Bwssb Sr 21-22 22.4 1X3x6 Sqmm, Providing , Supplying To Work Site , Submersible Pump Set Of 150Mm Dia Suitable For Bore Well And Conforming To Is 8034-2000 : 3 Phase Ss Bowl & Impeller With Low Volt Motor As Per Specifications As Per Necessary Amendments And Instructions Of Engineer –In- Charge Of Work Pg 159 / 11.5 11.5 3.00 Hp – 90 Lpm @ 66 Mtr= 6 Stage Outlet Dia 2 “, Providing , Supplying To Work Site , Submersible Pump Set Of 150Mm Dia Suitable For Bore Well And Conforming To Is 8034-2000 : 3 Phase Ss Bowl & Impeller With Low Volt Motor As Per Specifications As Per Necessary Amendments And Instructions Of Engineer –In- Charge Of Work Pg 159 / 11.5 13.6 5.00 Hp – 90 Lpm @ 110 Mtr= 10 Stage Outlet Dia 2 .00“, Providing , Supplying To Work Site , Submersible Pump Set Of 150Mm Dia Suitable For Bore Well And Conforming To Is 8034-2000 : 3 Phase Ss Bowl & Impeller With Low Volt Motor As Per Specifications As Per Necessary Amendments And Instructions Of Engineer –In- Charge Of Work Pg 159 / 11.5 16.1 10.00 Hp – 360 Lpm @ 75 Mtr= 5 Stage Outlet Dia 2 .00“, Work Of Servicing, Leak Arresting And Oil Filtration Upto 500 Kva Power Transformers As Specified Below: A. Removing Cable Connection Of Transformer After Isolating The Supply Dismantling The Cable Connection B. Replacing The Existing Leakage L.V Side H.T Busing Gasket, Oil Seal, Bots And Nuts Etc. Of The Power Transformer. C. Replacing The Existingnon-Functioned Damaged Dehydrating Breather By A New Breather With New Silica Gel For The Above Transformer D. Arresting Oil Leak From Exclusive Vent, Neutral Bushing Of Valves, Flanges, Is Drying Arresting The Leakage For L.V And Hv Side Of Power Transformer And Refilling Of The Transformer Oil Including Cost Of Labour And Necessary Repaired Materials.E. Repaint The Transformer Using Light Grey Epoxy Paint Of 2 Coated As Original. F. Filtering Of Oil In The Transformer At The Transformer Center By Hot Process Using Stream Line Filter Such That The Ielectric Strength Of Oil In The Transformer Conforms To Isi Specification. G. Painting Of Entirestructure Of Transformer Yard Including Fencing Using Silver Paint. Pg 11 Bwssb Sr 21-22 Pg 211 / Item 3, Work Of Repairs / Servicing And Overhauling Of On Load Tap Changer ( Oltc ) Of Upto 500 Kva Transformer As Specified Below:Painting Of Transformer Including Platform Cts Etc., With One Cost Of Red Oxide To The Rusted Portion Of Transformer, 2 Coats Of M / S Grey Enamel Paint, Ryb Color Paint To Ct Caps For Identification Etc., Rates Should Quote Inclusive Of Cleaning Of The Transformer Of All Sizes., Works Of Supply Fixing And Wiring Of Tap Position Indicator To Rtcc Panel Transformer As Detailed:. Tap Position Indicator Aux Supply: -110V Or 230V Ac +15% 50Hz, Resistance: - 1 Kilo Ohms Per Step, Tele-Transmitter: -3Wire Connection 1 To 99 Position, Display: -2Digit 7 Segment Led, Accuracy -Tolerance +2%, Type Of Mounting: -Panel Mounting 90X90x70mm, Dimension: -96Mm X 96Mm X 70Mm, Accuracy: -Class Ii Pg 212 / 7 Bwssb Sr 21-22, Work Of Supply, Erection And Commissioning Of Indoor Upto 250 Amps Distribution Panel As Specified Below: Supply, Erection And Commissioning Of Indoor Type Upto 250 Amps Mccb Distribution Panel With Outgoing Copper Bus Bar, Having, Accessories Like Mccb, Incoming And Outgoing Entry Bus Bar, Ammeter Volt Meter, Ammeter Selector Switch, Led Indication Lamp, And With Suitable M.S Box With Required Stand Unit Set. Suitable For Indoor Type Complete As Per Latest Is Standard Specification. Each Pg 213 / 9 Bwssb Sr 21-22, Work Of Supply And Fixing Of 85W, Led High Way Fitting To Top Of Panel Board, Soft Starter And Breaker As Specified Below: Supplying High Pressure High Way 85W Led Fitting Die Cast Aluminum Canopy With Aluminum Housing To Control Gear, Finished Stove Enamel Gray Glassy White Canopy Interior With A Pair Of Anodized Aluminum Reflectors Clear Acrylic Bowl, Gasket Lining For Dip Inseat Resistance Duly Wired With Single Or Multi Leds. Pg 213 / Item 10 Bwssb Sr 21-22, Working Of Repairing And Overhauling Of Upto 800Amps As Specified Below: Complete Dismantling Of Breaker Units Of Upto 800 Amps Breaker Of Filter House Taking Out The Fixed And Moving Contacts Of All The Poles, Cleaning And Putting Back With Necessary Lubrication And Checking Of Complete Electrical Circuit For Proper Closing And Tripping Including Necessary Replacement Of ‘V’ Bar Contact, Finger Contact, Contact Tips, Arching Contact, Tripping And Closing Coil, Back Housing Set, With Female Contacts, Panel Fixed Contact Set Including Hylem Sheet With Contacts, Gasket And Dash Pit Oil Etc., Testing Of Tripping And Closing Mechanism In Order To Ensure Easy Of Operation Of The Breaker And Commissioning Of The System As Per The Standard Practice Without Interruption Of Power Supply. Pg 215 / Item 18 Bwssb Sr 21-22, Work Of Repairing And Overhauling Of Upto 400 Amps Lt Breaker Bus Coupler As Specified Below: Complete Dismantling Of Breaker Units Of 400 Amps, Breaker Of Compressor Room Taking Out The Fixed And Moving Contacts Of Al Limbs, Cleaning And Putting Back With Necessary Lubrication And Checking Of Complete Electrical Circuit For Proper Closing And Tripping Including Necessary Replacement Of V Bar Contact Finger Contact, Contact Tips Of Arcing, Contacts Of Tripping And Closing Coil, Back Housing Set, Gasket And Dash Pot Oil Etc.. Testing And Tripping And Closing Mechanism In Order To Ensure Easy Operation Of The Breaker And Commissioning Of The System As Per The Standard Practice Without Interruption Of Power Supply. Pg 215 / Item 19 Bwssb Sr 21-22, Cutting Of The Damaged Portion Of Upto 3X150sq.Mm Xlpe Cable Supplying One Number Of Indoor Termination Kit Upto 3X150sq.Mmhtxlpe Cable And Attending The Termination Work Upto 3X150sq.Mm Ht Cable Of Neutral Side Cable By Using Upto 150Sq.Mm Copper Lugs, Self Adhesive Ht Tape, Crimping Tool, Heat Shrinkable Termination Kit And Required Bolts And Nuts Etc., And Commissioning The Motor On Load. The Work Including The Cost Of Materials, Labour Charges, Taxes And Rebatetowards The Cost Of Released Materials Etc Pg 216 / 22 Bwssb Sr 21-22, Removing & Refixing The Pump After Repairing Of Existing Horizontal Mounting / Monoblock Pump With Following Spares, Etc. Including Aligning Of Pump With Reference To Motor & Running The Pump On Load Pg 216 / Item 26.1 Up To 5 Hp, Removing & Refixing The Pump After Repairing Of Existing Horizontal Mounting / Monoblock Pump With Following Spares, Etc. Including Aligning Of Pump With Reference To Motor & Running The Pump On Load Pg 216 / Item 26.2 5 Hp To 10 Hp, Supply And Deliver At Site Of Brand New Best Make Gate Valve As Per Is 778 / 1984 With Isi Mark And As Per Its Latest Amendments Pg 162 / 27.1 Bwssb Sr 21-22 27.1 Size 50Mm, Supply And Deliver At Site Of Brand New Best Make Gate Valve As Per Is 778 / 1984 With Isi Mark And As Per Its Latest Amendments Pg 162 / 27.1 Bwssb Sr 21-22 27.2 Size 65 Mm, Supply And Delivery At Site New Best Brand Make Non Return Valve As Per Is 778 / 1984 With Isi Mark And As Per Its Latest Amendments Pg 162 / 28 Bwssb Sr 21-22 28.1 Size 50Mm, Supply And Delivery At Site New Best Brand Make Non Return Valve As Per Is 778 / 1984 With Isi Mark And As Per Its Latest Amendments Pg 162 / 28 Bwssb Sr 21-22 28.2 Size 65Mm, Providing Ht Cable Jointing 3 Core 240 Sqmm Including Providing Megger Test For Both Side Supply And Return With All Materials And Labour Charges For Digging The Trenches And Re Filling The Trenches, Providing Lt Cable Jointing 3.5 Core 240 / 300 / 400 Sqmm Including Providing Megger Test For Both Side Supply And Return With All Materials And Labour Charges For Digging The Cable, Supply, Installing, Testing And Commissioning Common Control Panel Consisting Of The Following Incoming:1 No Set Of Phase Indicating Lamps With Sfu Of Suitable Rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1Ni With Phase Selector Switch, Isolating Switch Outgoing For Main Electrical Pump: 1 No. Mcb 1 No. Dol Of S / D Starter Suitable For Respective Hp 1 No. Electrcal Protection Like Single Phase Preventor, Under Voltage Over Volage, Under Current Over Current & Dry Run Protection Suitable For The Pump Described Above 1 No Indoor Type Note : 1 Dol Direct On –Line Starter S-D- Star Delta Starter Pg 162 / Item 29 29.1 Up To 6 Hp Pumps, Supply, Installing, Testing And Commissioning Common Control Panel Consisting Of The Following Incoming:1 No Set Of Phase Indicatinglamps With Sfu Of Suitable Rating 1 No, Analog Ammeter, 1 No Analogvoltmeter 1Ni With Phase Selector Switch, Isolating Switch Outgoing For Main Electrical Pump: 1 No. Mcb 1 No. Dol Of S / D Startersuitable For Respective Hp 1 No. Electrcal Protection Like Single Phasepreventor, Under Voltage Over Volage, Under Current Over Current & Dryrun Protection Suitable For The Pump Described Above 1 No Indoor Type Note : 1 Dol Direct On –Line Starter S-D- Star Delta Starter Pg 162 / Item 29 29.2 6 Hp To 15 Hp Pumps, Supply And Delivery At Site Of Best Indigenous Brand New Mcb ( Miniature Circuit Breakers ) Of Required Capacity As Per Is 88228 / 1978 And Its Latest Amendments With Isi Mark Of 6 / 10 / 16 / 20 / 25 / 40 Amps With Scalable Box Pg 162 / 32 Bwssb Sr 21-22, Supply Aand Delivery At Site Indigenous Brand New Power Capacitors As Per Is 2834 / 1986 With Latest Amendments With Kptcl Authorities And Errection , Electrification And Conmmissioning Of The Same At Location Of Respective Pump Sets.., Providing , Supplying To Work Site , Single Phase Submersible Pump Set Pf 100Mm Dia ( 4 Inch ) Suitable For Bore Well Conforming To Is 8034 -2000 Specifications , With Testing Of As Per Instructions Of Engineer In Charge Of Work And Latest Amendments Pg 158 / Item 6 Bwssb Sr 21-22 6.1 1.00 Hp / 0.75 Kw , 7 Stg, Providing Pvc Pipes Od 25Mm And 10 Kg / Sqcm Pg 34 / 1176 Bwssb Sr 21-22, Providing Pvc Pipes Od 32Mm And 10 Kg / Sqcm Pg 34 / 1178 Bwssb Sr 21-22, Providing Pvc Pipes Od 50Mm And 10 Kg / Sqcm Pg 34 / 1179 Bwssb Sr 21-22, Providing Pvc Pipes Od 90Mm And 10 Kg / Sqcm Pg 34 / 1182 Bwssb Sr 21-22, Providing Pvc Pipes Od 75Mm And 10 Kg / Sqcm Pg 34 / 1181 Bwssb Sr 21-22, Providing Repairs Of Oltc Transformers Upto 500 Kva Bwssb Sr 21-22 Pg No 36 / 1250, Replacement Of Gland Packing With All Materials Etc.. Complete Pg 37 / Item 1258 Bwssb Sr 21-22, Providing Servicing To 500 Kva Transformer Pg 38 / Item 1308 Bwssb Sr 21-22, Supply And Fixing Of Insulator For Ht Panel Pg 38 / 1318 Bwssb Sr 21-22, Providing Digital Hygrometer With Nabl Certificate Pg 102 / 3.87 Bwssb Sr 21-22, Labour Charges Foroverhauling Of The Pump Set Pg 157 / 3.21 Bwssb Sr 21-22, Providing Rewinding. / Reconditioning Of The 5 Hp Submergiblepumpsets, Items Requiring Replacements Decided By The Departmental Officials, With Respective Make Of Damaged Ones, Including All Materials, Labour, Equipments And Testing. Lifting Of The Submersible Motor From The Well And Re- Errection Charges And Complete Overhauling Etc.., Providing Human Resource Including Wireman / Electricians / Dg Operators / Ac Technicians Rs 496.22 / Per Person / Per Day / Rs 14, 886.60X12=1, 78.639.20 Pwd Sr 20-21 Pg No: A-51 Item 27, Supplying , Installation , Testing And Commissioning Of 12 Volt Dc , 100 Ah Batteries In Poly Propylene Container For Dg Sets , Low Maintenance Batteries Plate Type Pg 29 Item 9.4 9.4.4 100 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Volt Dc , 100 Ah Batteries In Poly Propylene Container For Dg Sets , Low Maintenance Batteries Plate Type Pg 29 Item 9.4 9.4.5 120 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Volt Dc , 100 Ah Batteries In Poly Propylene Container For Dg Sets , Low Maintenance Batteries Plate Type Pg 29 Item 9.4 9.4.6 150 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Volt Dc , 100 Ah Batteries In Poly Propylene Container For Dg Sets , Low Maintenance Batteries Plate Type Pg 29 Item 9.4 9.4.7 200 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Dc , 7 Ah Batteries In Poly Propylene Container For U.P.S Sealed Maintenance Batteries Pg 29 Item 9.5.1 9.5.1 7 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Dc , 18 Ah Batteries In Poly Propylene Container For U.P.S Sealed Maintenance Batteries Pg 29 Item 9.5.2 9.5.2 18 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Dc , 26 Ah Batteries In Poly Propylene Container For U.P.S Sealed Maintenance Batteries Pg 29 Item 9.5.3 9.5.3 26 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Dc , 42 Ah Batteries In Poly Propylene Container For U.P.S Sealed Maintenance Batteries Pg 29 Item 9.5.4 9.5.4 42 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Dc , 60 / 65 Ah Batteries In Poly Propylene Container For U.P.S Sealed Maintenance Batteries Pg 29 Item 9.5.5 9.5.5 60 / 65 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Dc , 75 / 80 Ah Batteries In Poly Propylene Container For U.P.S Sealed Maintenance Batteries Pg 29 Item 9.5.6 9.5.6 75 / 80 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Dc , 100 Ah Batteries In Poly Propylene Container For U.P.S Sealed Maintenance Batteries Pg 29 / 30 Item 9.5.7 9.5.7 100 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Dc , 120 Ah Batteries In Poly Propylene Container For U.P.S Sealed Maintenance Batteries Pg 29 / 30 Item 9.5.8 9.5.8 120 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Dc , 150 Ah Batteries In Poly Propylene Container For U.P.S Sealed Maintenance Batteries Pg 29 / 30 Item 9.5.9 9.5.9 150 Ah Capacity, Supplying , Installation , Testing And Commissioning Of 12 Dc , 200 Ah Batteries In Poly Propylene Container For U.P.S Sealed Maintenance Batteries Pg 29 / 30 Item 9.5.9 9.5.10 200 Ah Capacity, Supplying Of .....Feet -Pvc Batten With Integrated Ledtube....W With High Quality Diffuser With Life Of 25000Burninghours & 70% Lumen Maintenance With Cri≫80.Powerinput: 220-240V@ 50 / 60Hz & Power Factor≫0.9Alongwithceapproved. 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition Pg 34 / 11.3 11.3.1 Led Light Fitting 1X2’-9 / 10 Watt, Supplying Of .....Feet -Pvc Batten With Integrated Led Tubew With High Quality Diffuser With Life Of 25000 Burning Hours & 70% Lumen Maintenance With Cri ≫ 80.Powerinput: 220-240V@ 50 / 60Hz & Power Factor ≫0.9Alongwithceapproved. 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition Pg 34 / 11.3 .2 11.3.2 Led Light Fitting 1X4’-20 / 22 Watts, Supplying Of .....Feet -Pvc Batten With Integrated Led Tube...W With High Quality Diffuser With Life Of 25000 Burninghours & 70% Lumen Maintenance With Cri ≫ 80.Powerinput: 220-240V@ 50 / 60Hz & Power Factor ≫0.9Alongwithceapproved. 2 Years Warranty Against Anymanufacturingdefectworking Under Standard Electrical Condition Pg 34 / 11.3 .2 11.3.2 Led Light Fitting 1X4’-36 / 40 Watts, Led Down Light Supplying Of Recess Mounting Non Integrated Type Led Down Light...... W Luminaire Comprising Of Pressure Decast / Extruded Aluminium Housing, With Spring Loaded Falseceilingcla, Led Of Power / Cob With Cct 6500 Degreek, Cri≫70%. Efficacy ≫100 Lumen Per W, 120Degreebeamspread, Life≫ 25000 Burning Hours And Compliancetois10322 / Iec60598, Lm 79 & Lm 80. The Lamp Compartment Is Enclosed With Anti Glare Opal Diffuser Which Enhances The Lighting Level. Leds Are Driven By Hf Electronic Driver Integrated In Separate Control Gear Assembly., With Pf ≫ 0.95, Powerlossshould≪ 5% Of Lamp Wage, Short Circuit &Opencircuitprotection To Be Integrated In The Circuit, Thdlessthan20%, Life As Per Lm 79. The Operating Input Voltage Should Be Between 130 To 275 V. Bis Approved And Tested By Nabl / Cpri Accredited Laboratory With 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition Pg 34 / 11.4.1 11.4.1 5-6 Watts, Led Down Light Supplying Of Recess Mounting Non Integrated Type Led Down Light...... W Luminaire Comprising Of Pressure Decast / Extruded Aluminium Housing, With Spring Loaded Falseceilingcla, Led Of Power / Cob With Cct 6500 Degreek, Cri≫70%. Efficacy ≫100 Lumen Per W, 120Degreebeamspread, Life≫ 25000 Burning Hours And Compliancetois10322 / Iec60598, Lm 79 & Lm 80. The Lamp Compartment Is Enclosed With Anti Glare Opal Diffuser Which Enhances The Lighting Level. Leds Are Driven By Hf Electronic Driver Integrated In Separate Control Gear Assembly., With Pf ≫ 0.95, Powerlossshould≪ 5% Of Lamp Wage, Short Circuit &Opencircuitprotection To Be Integrated In The Circuit, Thdlessthan20%, Life As Per Lm 79. The Operating Input Voltage Should Be Between 130 To 275 V. Bis Approved And Tested By Nabl / Cpri Accredited Laboratory With 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition Pg 34 / 11.4.1 11.4.2 10-12 Watts, Led Down Light Supplying Of Recess Mounting Non Integrated Type Led Down Light...... W Luminaire Comprising Of Pressure Decast / Extruded Aluminium Housing, With Spring Loaded Falseceilingcla, Led Of Power / Cob With Cct 6500 Degreek, Cri≫70%. Efficacy ≫100 Lumen Per W, 120Degreebeamspread, Life≫ 25000 Burning Hours And Compliancetois10322 / Iec60598, Lm 79 & Lm 80. The Lamp Compartment Is Enclosed With Anti Glare Opal Diffuser Which Enhances The Lighting Level. Leds Are Driven By Hf Electronic Driver Integrated In Separate Control Gear Assembly., With Pf ≫ 0.95, Powerlossshould≪ 5% Of Lamp Wage, Short Circuit &Opencircuitprotection To Be Integrated In The Circuit, Thdlessthan20%, Life As Per Lm 79. The Operating Input Voltage Should Be Between 130 To 275 V. Bis Approved And Tested By Nabl / Cpri Accredited Laboratory With 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition Pg 34 / 11.4.1 11.4.3 15-18 Watts, Supply Of Round / Square Recess / Surface Mounted Rolling Type Led Down Light With ...... W Gu 10 Led Lamp Rib Fabricated From Diecast Aluminium With White Powdercoated Prewired To Mains Connector & Has Swivelling Unit Aluminium Die Cast Eye Ball & Led Lamp Position Retainedcircular Wire Spring, With Life Of 25000 Burning Hours&70%Lumen Maintenance With Cri ≫ 80. Power Input:220-240V@50 / 60Hz & Power Factor ≫0.9 Along With Ce Approved. 2Yearswarranty Against Any Manufacturing Defect Working Understandard Electrical Condition Pg 34 / Item 11.5 11.5.1 Led Square Or Round Down Light 5-6 Watts, Supply Of Round / Square Recess / Surface Mounted Rolling Type Led Down Light With ...... W Gu 10 Led Lamp Rib Fabricated From Diecast Aluminium With White Powdercoated Prewired To Mains Connector & Has Swivelling Unit Aluminium Die Cast Eye Ball & Led Lamp Position Retainedcircular Wire Spring, With Life Of 25000 Burning Hours&70%Lumen Maintenance With Cri ≫ 80. Power Input:220-240V@50 / 60Hz & Power Factor ≫0.9 Along With Ce Approved. 2Yearswarranty Against Any Manufacturing Defect Working Understandard Electrical Condition Pg 34 / Item 11.5 11.5.5 Led Square Or Down Light 10-12 Watts, Supply Of Round / Square Recess / Surface Mounted Rolling Type Led Down Light With ...... W Gu 10 Led Lamp Rib Fabricated From Diecast Aluminium With White Powdercoated Prewired To Mains Connector & Has Swivelling Unit Aluminium Die Cast Eye Ball & Led Lamp Position Retainedcircular Wire Spring, With Life Of 25000 Burning Hours&70%Lumen Maintenance With Cri ≫ 80. Power Input:220-240V@50 / 60Hz & Power Factor ≫0.9 Along With Ce Approved. 2Yearswarranty Against Any Manufacturing Defect Working Understandard Electrical Condition Pg 34 / Item 11.5 11.5.3 Led Square Or Down Light 15-18 Watts, Supplying Of Recess Mounting Non Integral Type ........ Ledw Luminaire Comprising Of Pressure Decast / Extrudedaluminiumhousing, With Spring Loaded False Ceiling Cla, Power Leds With Cct 6500 Degree K, Cri≫ 70%. Efficacy ≫ 100 Lumen Perw, 120Degree Beam Spread, Life≫ 25000 Burning Hoursandcompliance To Is 10322 / Iec 60598, Lm 79 & Lm80.The Lamp Compartment Is Enclosed With Anti Glare Opal Diffuser Which Enhances The Lighting Level Leds Are Drivenbyhf Electronic Driver Integrated In A Separate Control Gear Assembly., With Pf ≫ 0.95, Power Loss Should≪ 5% Of Lampwage., Short Circuit & Open Circuit Protection To Beintegratedin The Circuit, Thd Less Than 20%, Life As Perlm79.Theoperating Input Voltage Should Be Between 130 To 275 Volts.Bisapproved And Tested By Nabl / Cpri Accredited Laboratorywith 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition. N Pg 35 / 11.6 11.6.1 Led Modular Down Light 1X1 34-22 W, Supplying Of Recess Mounting Non Integral Type ........ Ledw Luminaire Comprising Of Pressure Decast / Extrudedaluminiumhousing, With Spring Loaded False Ceiling Cla, Power Leds With Cct 6500 Degree K, Cri≫ 70%. Efficacy ≫ 100 Lumen Perw, 120Degree Beam Spread, Life≫ 25000 Burning Hoursandcompliance To Is 10322 / Iec 60598, Lm 79 & Lm80.The Lamp Compartment Is Enclosed With Anti Glare Opal Diffuser Which Enhances The Lighting Level Leds Are Drivenbyhf Electronic Driver Integrated In A Separate Control Gear Assembly., With Pf ≫ 0.95, Power Loss Should≪ 5% Of Lampwage., Short Circuit & Open Circuit Protection To Beintegratedin The Circuit, Thd Less Than 20%, Life As Perlm79.Theoperating Input Voltage Should Be Between 130 To 275 Volts.Bisapproved And Tested By Nabl / Cpri Accredited Laboratorywith 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition. N Pg 35 / 11.6 11.6.2 Led Modular Down Light 2X2 / 1X4 34-36 W, Supplying Of Recess Mounting Non Integral Type ........ Ledw Luminaire Comprising Of Pressure Decast / Extrudedaluminiumhousing, With Spring Loaded False Ceiling Cla, Power Leds With Cct 6500 Degree K, Cri≫ 70%. Efficacy ≫ 100 Lumen Perw, 120Degree Beam Spread, Life≫ 25000 Burning Hoursandcompliance To Is 10322 / Iec 60598, Lm 79 & Lm80.The Lamp Compartment Is Enclosed With Anti Glare Opal Diffuser Which Enhances The Lighting Level Leds Are Drivenbyhf Electronic Driver Integrated In A Separate Control Gear Assembly., With Pf ≫ 0.95, Power Loss Should≪ 5% Of Lampwage., Short Circuit & Open Circuit Protection To Beintegratedin The Circuit, Thd Less Than 20%, Life As Perlm79.Theoperating Input Voltage Should Be Between 130 To 275 Volts.Bisapproved And Tested By Nabl / Cpri Accredited Laboratorywith 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition. N Pg 35 / 11.6 11.6.3 Led Modular Down Light 2’X2’ / 1’X4’ 42-55 Watts, Supply Of Led Floodlight Luminaire With Pressure Die Cast Luminium Housing Body For Optimal Thermal Dissipation.Lamp Compartment Comprising Of Anti Glare Clear Diffuser With Injection Moulded Polycarbonate / Clear Glass Material, Delivering Superior Light Output Rated Life Burning Hrs 50000 Hr @ Lumen Maintenance Of 70%, Cct ≫ 5500K, Ip66optical And Electrical Compartment & Impactresistanceofcomplete Luminaire ≫ Ik08. Power Factor ≫0.9 With Mains, Surge Protection- Min 5Kv Along With Over Voltage / Overload, Short Circuit / Miss-Wiring Protection. Compatiblefor Pole Mauling With Outer Dia Of 40Mm To 50Mm.Universalvoltage Driver To Operate Wide Voltage Range From 100 V To 270V 50 / 60Hz Application. Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80 Adherence With Rohs. Ul Approvedmcpcb. Top Access Street Light With Single Screwtoensureease Of Maintenance At The Sight Site Locationwithminimized Minimal Tools. Led Light Fixture With ....... W System Power Consumption. Led Efficiency≫ 1301M / W, Nominalcri≫75. Luminaire Manufacturer Should Have In-Housefacilityaccredited By Nabl / Cpri & Any Governmentcertifiedagency & Design & Development Facility Certified By Iso 9001:2008. Housing With Supplier Word Mark / Name Shall Engraved / Embossing On The Die Cast Housing / Body Partwarranty Of 2 Years Against Any Manufacturing Defect Working Under Standard Electrical Conditions As Mentioned Pg 37 / 11.9 11.9.5 Led Flood Light 180 Watts, Supply Of Led Floodlight Luminaire With Pressure Die Cast Luminium Housing Body For Optimal Thermal Dissipation.Lamp Compartment Comprising Of Anti Glare Clear Diffuser With Injection Moulded Polycarbonate / Clear Glass Material, Delivering Superior Light Output Rated Life Burning Hrs 50000 Hr @ Lumen Maintenance Of 70%, Cct ≫ 5500K, Ip66optical And Electrical Compartment & Impactresistanceofcomplete Luminaire ≫ Ik08. Power Factor ≫0.9 With Mains, Surge Protection- Min 5Kv Along With Over Voltage / Overload, Short Circuit / Miss-Wiring Protection. Compatiblefor Pole Mauling With Outer Dia Of 40Mm To 50Mm.Universalvoltage Driver To Operate Wide Voltage Range From 100 V To 270V 50 / 60Hz Application. Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80 Adherence With Rohs. Ul Approvedmcpcb. Top Access Street Light With Single Screwtoensureease Of Maintenance At The Sight Site Locationwithminimized Minimal Tools. Led Light Fixture With ....... W System Power Consumption. Led Efficiency≫ 1301M / W, Nominalcri≫75. Luminaire Manufacturer Should Have In-Housefacilityaccredited By Nabl / Cpri & Any Governmentcertifiedagency & Design & Development Facility Certified By Iso 9001:2008. Housing With Supplier Word Mark / Name Shall Engraved / Embossing On The Die Cast Housing / Body Partwarranty Of 2 Years Against Any Manufacturing Defect Working Under Standard Electrical Conditions As Mentioned Pg 37 / 11.9 11.9.6 Led Flood Light 200 Watts, Supply Of Led Streetlight Luminaire With Pressure Die Cast Luminium Housing Body For Optimal Thermal Dissipation.Lamp Compartment Comprising Of Anti Glarecleardiffuserwith Injection Moulded Polycarbonate Material, Deliveringsuperior Light Output Rated Life Burning Hrs 50000 Hr @Lumen Maintenance Of 70%, Maximum Light Intensityshouldbe Between 60 Degrees To 70 Degrees. Cct≫5500K, Ip66optical And Electrical Compartment & Impactresistanceofcomplete Luminaire ≫ Ik08. Power Factor≫0.9Withmains, Surge Protection- Min 5Kv Along With Over Voltage / Overload, Short Circuit / Miss-Wiring Protection. Compatiblefor Pole Mounting With Outer Dia Of 40Mm To 50Mm. Universalvoltage Driver To Operate Wide Voltage Range From100vto270v50 / 60Hz Application. Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80 Adherence With Rohs. Ul Approved Mcpcb.Top Access Street Light With Single Screw To Ensure Ease Of Maintenance At The Sight Site Location With Minimized Minimaltools. Led Light Fixture With ........W System Powerconsumption. Led Efficiency≫1301M / W, Nominal Cri ≫75. Luminaire Manufacturer Should Have In-House Facilityaccredited By Nabl / Cpri & Any Government Certified Agency & Design & Development Facility Certified By Iso 9001:2008. Housing With Supplier Word Mark / Name Shall Be Engraved / Embossing On The Die Cast Housing / Body Part. Warranty Of 2 Years Against Any Manufacturing Defect Working Under Standard Electrical Conditions As Mentioned Pg 37 / 11.8 11.8.4 Led Street Light 90 Watts, Supply Of Led Streetlight Luminaire With Pressure Die Cast Luminium Housing Body For Optimal Thermal Dissipation.Lamp Compartment Comprising Of Anti Glarecleardiffuserwith Injection Moulded Polycarbonate Material, Deliveringsuperior Light Output Rated Life Burning Hrs 50000 Hr @Lumen Maintenance Of 70%, Maximum Light Intensityshouldbe Between 60 Degrees To 70 Degrees. Cct≫5500K, Ip66optical And Electrical Compartment & Impactresistanceofcomplete Luminaire ≫ Ik08. Power Factor≫0.9Withmains, Surge Protection- Min 5Kv Along With Over Voltage / Overload, Short Circuit / Miss-Wiring Protection. Compatiblefor Pole Mounting With Outer Dia Of 40Mm To 50Mm. Universalvoltage Driver To Operate Wide Voltage Range From100vto270v50 / 60Hz Application. Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80 Adherence With Rohs. Ul Approved Mcpcb.Top Access Street Light With Single Screw To Ensure Ease Of Maintenance At The Sight Site Location With Minimized Minimaltools. Led Light Fixture With ........W System Powerconsumption. Led Efficiency≫1301M / W, Nominal Cri ≫75. Luminaire Manufacturer Should Have In-House Facilityaccredited By Nabl / Cpri & Any Government Certified Agency & Design & Development Facility Certified By Iso 9001:2008. Housing With Supplier Word Mark / Name Shall Be Engraved / Embossing On The Die Cast Housing / Body Part. Warranty Of 2 Years Against Any Manufacturing Defect Working Under Standard Electrical Conditions As Mentioned Pg 37 / 11.8 11.8.5 Led Street Light 120 Watts, Supply Of Led Streetlight Luminaire With Pressure Die Cast Luminium Housing Body For Optimal Thermal Dissipation.Lamp Compartment Comprising Of Anti Glarecleardiffuserwith Injection Moulded Polycarbonate Material, Deliveringsuperior Light Output Rated Life Burning Hrs 50000 Hr @Lumen Maintenance Of 70%, Maximum Light Intensityshouldbe Between 60 Degrees To 70 Degrees. Cct≫5500K, Ip66optical And Electrical Compartment & Impactresistanceofcomplete Luminaire ≫ Ik08. Power Factor≫0.9Withmains, Surge Protection- Min 5Kv Along With Over Voltage / Overload, Short Circuit / Miss-Wiring Protection. Compatiblefor Pole Mounting With Outer Dia Of 40Mm To 50Mm. Universalvoltage Driver To Operate Wide Voltage Range From100vto270v50 / 60Hz Application. Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80 Adherence With Rohs. Ul Approved Mcpcb.Top Access Street Light With Single Screw To Ensure Ease Of Maintenance At The Sight Site Location With Minimized Minimaltools. Led Light Fixture With ........W System Powerconsumption. Led Efficiency≫1301M / W, Nominal Cri ≫75. Luminaire Manufacturer Should Have In-House Facilityaccredited By Nabl / Cpri & Any Government Certified Agency & Design & Development Facility Certified By Iso 9001:2008. Housing With Supplier Word Mark / Name Shall Be Engraved / Embossing On The Die Cast Housing / Body Part. Warranty Of 2 Years Against Any Manufacturing Defect Working Under Standard Electrical Conditions As Mentioned Pg 37 / 11.8 11.8.6 Led Street Light 150 Watts, Supply Of Led Streetlight Luminaire With Pressure Die Cast Luminium Housing Body For Optimal Thermal Dissipation.Lamp Compartment Comprising Of Anti Glarecleardiffuserwith Injection Moulded Polycarbonate Material, Deliveringsuperior Light Output Rated Life Burning Hrs 50000 Hr @Lumen Maintenance Of 70%, Maximum Light Intensityshouldbe Between 60 Degrees To 70 Degrees. Cct≫5500K, Ip66optical And Electrical Compartment & Impactresistanceofcomplete Luminaire ≫ Ik08. Power Factor≫0.9Withmains, Surge Protection- Min 5Kv Along With Over Voltage / Overload, Short Circuit / Miss-Wiring Protection. Compatiblefor Pole Mounting With Outer Dia Of 40Mm To 50Mm. Universalvoltage Driver To Operate Wide Voltage Range From100vto270v50 / 60Hz Application. Compliance To Is 10322 / Iec 60598, Lm 79 & Lm 80 Adherence With Rohs. Ul Approved Mcpcb.Top Access Street Light With Single Screw To Ensure Ease Of Maintenance At The Sight Site Location With Minimized Minimaltools. Led Light Fixture With ........W System Powerconsumption. Led Efficiency≫1301M / W, Nominal Cri ≫75. Luminaire Manufacturer Should Have In-House Facilityaccredited By Nabl / Cpri & Any Government Certified Agency & Design & Development Facility Certified By Iso 9001:2008. Housing With Supplier Word Mark / Name Shall Be Engraved / Embossing On The Die Cast Housing / Body Part. Warranty Of 2 Years Against Any Manufacturing Defect Working Under Standard Electrical Conditions As Mentioned Pg 37 / 11.8 11.8.8 Led Street Light 200 Watts, Supplying And Fixing Of Slim Box Type Fitting , Made Out Of Crca Sheet Metal Body With Locking Type Holder Completely Wired Excluding Ballast & Flourescent Tube 1X2’ Tube Light Fitting, Supplying And Fixing Of Slim Box Type Fitting , Made Out Of Crca Sheet Metal Body With Locking Type Holder Completely Wired Excluding Ballast & Flourescent Tube 1X4” Tube Light Fitting, Supplying And Fixing Of Slim Box Type Fitting , Made Out Of Crca Sheet Metal Body With Locking Type Holder Completely Wired Excluding Ballast & Flourescent Tube 2X4’ Tube Light Fittings, Supplying And Fixing One Of 230 Volts Ding Dong Bell And A Flush Type Bell Push With Gang Box On Necessary Wooden Or Rawl Plugs Using Nf Screws With Remote Pg 39 / 12.2 12.2.3 Remote, Releasing An Unserviceable Thermostat And Providing In Its Place A New 20 A Capacity 25 Inch To 85 Inch Range Thermostat Pg 39 / 12.7, Releasing An Unserviceable Thermostat And Providing In Its Place A New 20 A Capacity 25 Inch To 85 Inch Range Thermostat For Racold Make Geysers, Releasing An Unserviceable Thermostat And Providing In Its Place A New 20 A Capacity 25 Inch To 85 Inch Range Thermostat For Haier Make Geysers, Releasing An Unserviceable Thermostat And Providing In Its Place A New 20 A Capacity 25 Inch To 85 Inch Range Thermostat For For Johnson / Bajaj Make Geysers, Supplying And Fixing / Replacement Of Heating Element For Geyser / Boiler Make: Racold / Smith, Supplying And Fixing / Replacement Of Heating Element For Geyser / Boiler Make: Johnson / Bajaj, Supplying And Fixing / Replacement Of Pressure Relief Valve Suitable For Geyser Pg 39 / 12.14, Supplying And Fixing / Replacement Of Round / Conical Diamond Shaped Hdpe Doom Suitable For 125 / 160 Watts Post Lamp Fittings Pg 39 / 12.15, Supplying And Fixing / Replacing Condenser For Ceiling Fan And Other Accessories Pg 39 / 12.3 12.3.1 Upto 4Mfd, Supplying And Fixing / Replacing Condenser For Ceiling Fan And Other Accessories Pg 39 / 12.3 12.3.3 10 Mfd, Supplying And Fixing / Replacing Condenser For Ceiling Fan And Other Accessories Pg 39 / 12.3 12.3.6 33 Mfd, Supplying And Fixing 6 Amps Capacity 4 Way Universal Shutter Type Spike Buster Suitable To Operate On 230 Volts 50 Hz Ac Supply Pg 40 / 12.16, Painting Of Existing Street Light Pole After Scrapping The Old Paint And Painted With Suitable Colour Enamel / Silver Paint Including Coping / Footing Of The Pole Pg 40 / 12.17 12.17.1 Up To 5 Mtr Street Light Pole, Painting Of Existing Street Light Pole After Scrapping The Old Paint And Painted With Suitable Colour Enamel / Silver Paint Including Coping / Footing Of The Pole Pg 40 / 12.17 12.17.2 Above 5.5 Mtr To 7.5 Mtr Strret Light Pole, Supplying & Fixing Led Drivers Suitable For 5700K Led Fitting Indoor Fixtures Operating Voltage Range From 180 Volts To 265 Volts Ac Power Supply Pg 43 / 12.51 12.51.7 36 Watts 5700 K Suitable For Indoor Led Fitting, Supplying & Fixing Led Drivers Suitable For 5700K Led Fitting Outdoor Fixtures Operating Voltage Range From 180 Volts To 265 Volts Ac Power Supply 12.52.4 90 Watts 5700K Suitable For Out Door Led Fitting, Supplying & Fixing Led Drivers Suitable For 5700K Led Fitting Outdoor Fixtures Operating Voltage Range From 180 Volts To 265 Volts Ac Power Supply 12.52.6 150 Watts 5700K Suitable For Outdoor Led Fittings, Supplying & Fixing Led Drivers Suitable For 5700K Led Fitting Outdoor Fixtures Operating Voltage Range From 180 Volts To 265 Volts Ac Power Supply 12.52.8 200 Watts 5700K Suitable For Out Door Led Fittings, Supplying And Fixing Of Led Projector Including Ceiling Mounting Brackets As Per The Site Condtions . Native Resolution –Xga ( 1024X768 ) Or Higher , Brightness -4000 Lumens Or Higher , Lamp Life Upto 10, 000 Hours, Contrast Ratio-16, 000:1 Or More, Video Compatibility –Ntsc, Pal, With Dual Port Hdmi, Audio- Audio Out Connector Support With 16 Watts Audio Out Put , Zoom / Focus Manual , Display Input Hdmix2, Usbx2 Composite A / V Wifi Automatic Connectivity With A Warranty Of One Year On Site Including Cost Of All Materials , Labour As Per Specifications & As Directed By Engineer-In- Charge Of The Work, Supplying And Fixing Of Lcd Projector Screen 5’X7’ ( Manual Type ) , Supplying And Drawing Hdmi Cable For Lcd Projector To Computer 15 Mtrs In Length, Supplying And Drawing Hdmi Cable For Lcd Projector To Computer 10 Mtrs In Length, Supplying And Drawing Hdmi Cable For Lcd Projector To Computer 5Mtrs In Length, Supplying And Drawing Hdmi Cable For Lcd Projector To Computer 2 Mtrs In Length, Supplying And Fixing Of Conversion Plugs 16 Amps For Imported Machines, Providing Audio Cables From Amplifier To Mic 15 Mtrs In Length With Pins And Soldering, Providing Wireless Receiver For Amplifier, Supplying And Fixing Of Additional Speakers From The Amplifier, Supplying And Drawing Speaker Cables From The Amplifier Including Supplying And Drawing Pvc Pipe 19 / 20Mm, Supplying And Fixing Of Vga To Hdmi Converter, Supplying And Fixing Of Vga To Hdmi Converter, Providing Services And Replacement Of Refrigerators Of Various Make Including Replacement Of Gaskets / Thermostat And Complete Overhauling, Supplying And Fixng Of Compressors Gr Refrigerators Including Leakage Arresting And Gas Charging, Supplying And Fixing Of Led Tv Full Hd 32 Inches Smart Tv , Supported Internet Services Netflix, Zee5, Hoichoi, Amazon Prime Video, Voot, Sonyliv, Disney+Hotstar, & Many More: Display Technology : Led , Resolution : 720P, Refresh Rate : 60 Hz With Special Feature : Google Tv / Watchlist / Voice Search / Google Play / Chromecast / Netflix / Amazon Prime Video / Additional Features: Apple Airplay / Apple Homekit / Alexagoogle Tv / Watchlist / Voice Search / Google Play / Chromecast / Netflix / Amazon Prime Video / Additional Features: Apple Airplay / Apple Homekit / Alexa With Mounting Hard Ware : Table Top Stand / Remote Controller Warranty Card, 1 Ac Adapter, 1 Ac Power Cord, 1 Remote Control, 1 Table-Top Stand, 1 User Manual, 2 Aaa Batteries Warranty : One Year Brand : Sony / Samsung / Lg, Supplying And Fixing Of Led Tv Full Hd 43 Inches Smart Tv , Supported Internet Services Netflix, Zee5, Hoichoi, Amazon Prime Video, Voot, Sonyliv, Disney+Hotstar, & Many More: Display Technology : Led , Resolution : 720P, Refresh Rate : 60 Hz With Special Feature : Google Tv / Watchlist / Voice Search / Google Play / Chromecast / Netflix / Amazon Prime Video / Additional Features: Apple Airplay / Apple Homekit / Alexagoogle Tv / Watchlist / Voice Search / Google Play / Chromecast / Netflix / Amazon Prime Video / Additional Features: Apple Airplay / Apple Homekit / Alexa With Mounting Hard Ware : Table Top Stand / Remote Controller Warranty Card, 1 Ac Adapter, 1 Ac Power Cord, 1 Remote Control, 1 Table-Top Stand, 1 User Manual, 2 Aaa Batteries Warranty : One Year Brand : Sony / Samsung / Lg, Supplying And Fixing Of Led Tv Full Hd 50 Inches Smart Tv , Supported Internet Services Netflix, Zee5, Hoichoi, Amazon Prime Video, Voot, Sonyliv, Disney+Hotstar, & Many More: Display Technology : Led , Resolution : 720P, Refresh Rate : 60 Hz With Special Feature : Google Tv / Watchlist / Voice Search / Google Play / Chromecast / Netflix / Amazon Prime Video / Additional Features: Apple Airplay / Apple Homekit / Alexagoogle Tv / Watchlist / Voice Search / Google Play / Chromecast / Netflix / Amazon Prime Video / Additional Features: Apple Airplay / Apple Homekit / Alexa With Mounting Hard Ware : Table Top Stand / Remote Controller Warranty Card, 1 Ac Adapter, 1 Ac Power Cord, 1 Remote Control, 1 Table-Top Stand, 1 User Manual, 2 Aaa Batteries Warranty : One Year Brand : Sony / Samsung / Lg, Supplying And Fixing Of Tata Play Set Top Bx With Stand, Supplying And Fixing Of Ceiling Mounting Bracket For 32 Inches Full Hd Led ( Same Manufacturer ) , Supplying And Fixing Of Ceiling Mounting Bracket For 43 Inches Full Hd Led ( Same Manufacturer ) , Supplying And Fixing Of Ceiling Mounting Bracket For 50 Inches Full Hd Led ( Same Manufacturer ) , Supplying Of 1.1 Kv Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975 ( Page No. 09 Item No.32 ) Bescom Sr Rs.183442 / - Per Km 32.05:- 16 Sqmm 4 Core ( 11 Gi Strips-4X0.8Mm, Supplying Of 1.1 Kv Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975 ( Page No. 09 Item No.32 ) Bescom Sr Rs.183442 / - Per Km 32.10 35 Sqmm 4 Core ( 15 Gi Strips-4X0.8Mm, Supplying Of 1.1 Kv Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975 ( Page No. 09 Item No.32 ) Bescom Sr Rs.183442 / - Per Km 32.12 50 Sqmm 4 Core ( 17 Gi Strips-4X0.8Mm, Supplying Of 1.1 Kv Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975 ( Page No. 09 Item No.32 ) Bescom Sr Rs.183442 / - Per Km 32.13 70 Sqmm 4 Core ( 18 Gi Strips-4X0.8Mm, Supplying Of 1.1 Kv Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975 ( Page No. 09 Item No.32.14 95 Sqmm 4 Core ( 18 Gi Strips-4X0.8Mm, Supplying Of 1.1 Kv Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975 ( Page No. 09 Item No.32.15 120 Sqmm 4 Core ( 18 Gi Strips-4X0.8Mm, Supplying Of 1.1 Kv Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975 ( Page No. 09 Item No.32.16 150 Sqmm 4 Core ( 25 Gi Strips-4X0.8Mm, Supplying Of 1.1 Kv Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975 ( Page No. 09 Item No.32.17 185 Sqmm 4 Core ( 28 Gi Strips-4X0.8Mm, Supplying Of 1.1 Kv Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975 ( Page No. 09 Item No.32.18 240 Sqmm 4 Core ( 30 Gi Strips-4X0.8Mm ) , Supplying Of 1.1 Kv Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975 ( Page No. 09 Item No.32.19 300 Sqmm 4 Core ( 32 Gi Strips-4X0.8Mm ) , Supplying Of 1.1 Kv Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975 ( Page No. 09 Item No.32.20 400 Sqmm 4 Core ( 39 Gi Strips-4X0.8Mm ) , Providing Copper Control Cables Pg 4 / 1.12 Kptcl Sr 21-22 1.12.5 2 Core 150 Sqmm, Providing Copper Control Cables Pg 4 / 1.12 Kptcl Sr 21-22 1.12.4 2 Core 50 Sqmm, Providing Copper Control Cables Pg 4 / 1.12 Kptcl Sr 21-22 1.12.7 4 Core 4 Sqmm, Providing Copper Control Cables Pg 4 / 1.12 Kptcl Sr 21-22 1.12.10 4 Core 16 Sqmm, Providing Copper Control Cables Pg 4 / 1.12 Kptcl Sr 21-22 1.12.10 4 Core 25 Sqmm, Providing Copper Control Cables Pg 4 / 1.12 Kptcl Sr 21-22 1.12.13 7 Core 2.5 Sqmm, Supply Of Control Cables Copper Core 32 Sqmm ( 2 Runs Of 1 Mtr Each ) Incuding Crimping With Lugs For Battery Terminals, Supplying Of 1.1 Kv Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975 ( Page No. 09 Item No.32 ) Bescom Sr Rs.183442 / - Per Km 32.05:- 16 Sqmm 4 Core ( 11 Gi Strips-4X0.8Mm ) , Laying Of Cable In Existing Trench / Gi Pipe / Stone Ware / Rcc Hume Pipe Using Wooden / Aluminum Rollers As Directed By The Departmental Staff Lt Cable ( Page No. 09 Item No. 39 ) Bescom Sr Sl No. 230 ) 31.05 ) 2.5 To 25 Sqmm, Earth Work Excavation For Cable Trench Of 0.5 To 0.75 Mtr. Width And Depth Upto 1 Mtr Including Trial Pits, Depositing On Bank Upto A Lead Of 50 Mtr, Supplying And Displaying Necessary Danger Boards And Lighting, Using Sight Rails And Sign Boards At Every 100 Mtr Wherever Necessary As Directed. ( Page No.07 & Item No.29.01 ) 29.03:- In Hard Soil, Good Quality Well Burnt Charcoal For Grounding Purposes Packed In Non Returnable Gunny Bag Of 30 Kg Each. ( Item No.54.02 ) . Material Code : 600095. Bescom Sr 2022-23., Good Quality Salt For Grounding Purposes Packed In 50 Kg Gunny Bag. ( Item No.54.03 ) . Material Code : 607054. Bescom Sr 2022-23., Ct Operated Etv Meter 0.2 S Accuracy With Abt Feature And Dlms Protocol With Tod With Rs 22 Port Unidirectional Used For Lt Metering Cubicle ( 50-150 Kw ) Bescom Sr 21-22 Pg 17 Item 56.03 ( Stock Of Materials ) , Supplying And Installation Of Smart Hd Ready 32 Inches Led Tv With Inbuilt Wi-Fi, Lan Port And Av Cable Port / Hdmi Port : Make : Lg / Samsung / Sony ) , Supplying And Installation Of Smart Hd Ready 43 Inches Led Tv With Inbuilt Wi-Fi, Lan Port And Av Cable Port / Hdmi Port : Make : Lg / Samsung / Sony ) , Supplying And Installation Of Smart Hd Ready 50 Inches Led Tv With Inbuilt Wi-Fi, Lan Port And Av Cable Port / Hdmi Port : Make : Lg / Samsung / Sony ) , Supplying And Fixing Of Advertising Full Hdled Display Refresh Rate :1920, Ac 110Volts / 220 Volts , 50 / 60 Hz, Supplying And Fixing Of 5’X7’ Led / Lcd Projector Screen Manually Operated, Water Purification Plants: Supplying, Installation And Commissioning Ofautomatic Water Purification Plant ( Ro+Uf ) With All Accessories Piping, Product Water Tank On Single Phase Power Supply As Per The Enclosed Detailed Technical Specifications Including Cost Of Material, Loading And Unloading And As Directed By The Engineer In Charge. ( Ref- Detailed Specification Enclosed Seperatly ) . Noteall Items Are To Bwssb Sr Rates 22-23 ( Iso / Ce Conformity ) Cabin Type :25Lph Ro Plant, Plumbing Charges For The Installation Of Ro 25 Lph Including Supplying And Fixing Of Heavy Duty Taps For The Outlet, Plumbing Charges For The Leakage Arresting Of The Solar Including The Replacement Of Gaskets With Sealant , Brazing And Welding Of The Gi Pipe For Each Place Of Leaking Including All Labour Charges, Providing Painting ( Two Coats ) To The Bottom Frame Of The The Dg Sets Including All Labour Charges And Materials, Providing Plumbing Charges For Arresting Leakages Of The Inlet And Oulet Pipes And Replacement Of Any Brokened Cpvc Pipe For Solar System, Providing High Pressure Pump 100 Gpd For 10 / 12 Lph, Water Purifier Including Labour And Material Charges, Providing 20 Inch Jumbo Post Carbon Filters Make : Kent / Live Pure, Providing 10 Inch Pre Filter Make : Kent / Live Pure, Providing One Time Complete Servicing Of The Water Purifier Including Inside And Out Side Cleaning Removing Of Dust And And Cleaning Entire Unit Of 25 Lph Water, Providing Ro Water 100 Gpd 24 Volt Booster Pump ( Ce / Iso Certified ) Make : Kent / Live Pure, Providing Complete Set Of Filters For 10 Lph Ro Plant Including Sediment / Pre Carbon / Post Carbon / Uf Filters Make : Kent / Live Pure, Providing Ro Membrane For 10 Lph Ro Water Purifier Make : Live Pure / Kent, Providing 12 / 15 / 18 Litres Of Ro Water Storage Tank Including Tap ( External Storage Tank, Providing Ro Membrane For 25 Lph Ro Water Purifier Make : Live Pure / Kent ( Ce / Iso / Bis Certified ) , Providing Sediment / . Pre Carbon, Post Cabon Filters For 25 Lph Ro Water Purifier At One Time Make : Live Pure / Kent ( Ce / Iso / Bis ) Certified ) , Providing Uf Filter For 25 Lph Ro Water Purifier Make : Kent / Live Pure ( Ce / Iso / Bis Certified ) , Providing Uf Filter For 10 Lph Ro Water Purifier Make : Kent / Live Pure ( Ce / Iso / Bis ) Certified ) , Providing Media For Jumbo Water Filters Sand And Carbon For 1000 Lph Water Purification Plant 3 Bags Of Sand , 65 Bags Of Activated Charcoal For Precarbon / Post Carbon, Providing 3500 Lph Motor For Ro Plant 500Lph / 1000Lph Including Complete Installation ( Ce / Iso Certified ) , Providing Ro Membrane For 500 Lph Ro Plant ( Ce / Iso Certified ) , Providing Ro Membrane For 1000 Lph Ro Plant Including All Materials And Labour Charges ( Ce / Iso Certified ) , Providing Raw High Pressure Pump For 500 Lph Ro Water Plant ( Ce / Iso Certified ) Stainless Steel , Vertical / Centrifugal Multistage, Flow Rate 2500 Litres Per Hour, Power Capacity 2 Kw , Make : Sumo / C.R.I Including All Plumbing Charges, Providing High Pressure Pump Got 1000 Lph Ro Water Plant Including All Material , Labour Charges ( Ce / Iso Certified ) Providing High Pressure Pump Got 1000 Lph Ro Water Plant ( Ce / Iso Certified ) Stainless Steel , Vertical / Centrifugal Multistage, Flow Rate 3500 Litres Per Hour, Power Capacity 2 Kw , Make : Sumo / C.R.I Including All Plumbing Charges, Providing Complete Cleaning Charges Inside .Outside The Storage Tanks Of 500 Lph Water Storage Tank , Cleaninf Of All Vessels And Complete Unit Of 500 / 1000 Litres Of Water Plant Once In A Month, Providing Uv Chamber For Water Purifier 10 / 15 Lph Make : Kent, Providing Uv Chamber For Water Purifier 25 Lph Ro Water Purifier Make: Kent, Providing Uv Chamber For Water Purifier 500 / 1000 Lph Ro Water Purifier Make : Kent / Live Pure, Providing 20 Inches Pre –Sediment Filter 5 Micron, Providing 10 Inches Pre –Solid Filter Catridge Poly Sting Wound Sediment Make: Kent / Live Pure, Supplying And Fixing Of Solenoid For 10 / 25 Lph Water Purifiers, Submitting The Compliance Report To The Electrical Inspectorate Including All Commissioning Approvals Of Dg Sets / Lifts / Test Reports Of Earth Leakage / Transformer Testing Reports Against The Observations Made By The Electrical Inspectorate, Supplying And Fixing Of Taps For 10 / 25 Lpf Ro Water Purifiers, Supplying And Fixing Of Heavy Duty Taps ( Steel Type ) For 500 / 1000Lph Water Purifiers ( , Providing Testing And Restting Of Rmus, Supplying And Fixing Of 3 Volts Lithium Batteries For Rmus, Providing Lcd Projector Lamp For Epson Make 3500 / 3800 Lumens, Providing Lcd Projector Lamp For Epson Make 4000 / 6000 Lumens, Providing Services For Lcd Projectors Including Cleaning Inside And Outside Once In 6 Months, Providing Crane Services For The Replacement Of Street Light Fittings At Quarters Area / Kmio Campus / Pcc Kalburgi
|