Supply, Installation, Commissioning Of Medical Equipments Supply, Installation, Commissioning, Provide 3 Years Comprehensive Warranty And 5 Years Camc After Expiry Of Warranty Period For The Supply Of Medical Equipment Required For All The Health Institutions , Shiotz Tonometer • Should Have High Quality Agate Bearing For An Extremely Long Service Life • Should Have Precision Measurement On A Scale Of 0 To 20 Subdivisions And 0 To -1 Sub-Divisions • Should Have Perfect Reading Of The Scale With Red Pointer • All Vital Parts Should Be Made Of Stainless Steel, Other Parts Should Be Made Of Chrome-Plated • Should Be Provided In A Deluxe Case With Velvet-Look Inserts • Supplied With Three Weights ( 5.5 G, 7.5 G, 10 G ) And A Conversion Table , Patient Unit For Ophthalmic Surgery Model:Aaot Specification Aaot Has A Maximum Height Of 920Mm And Minimum Height Of 690Mm, Ideal For Standing Or Sitting Working Position It Is An Ideal Operating Table With The Advantages Of Strong Applicability, Easy To Operate Adjust Conveniently, Steady Performance And So On Its Ergonomic Design Ensures Both Surgeon And Patient Comfort Patient Comfort Is Assured With Deep Antistatic Cushions Which Are Easy To Clean The Adjustable Cushioned Head-Rest Ensures Doctor Comfort And Restraint During Operations Up& Down Movements Minimum Height - 690Mm Maximum Height - 920Mm Stroke Length - 230Mm Weight Capacity - 250Kg Bed Tilting Backrest Section - 20º Leg Section - 30º Electrical Specification Motor - 24Vdc Power Supply - 110 / 230 V, 50-60Hz Power In Va - 115 Va Physical Parameters Dimension - 1900Mm ( L ) X 600Mm ( W ) , Urine Analyzer Specification * Small Footprint: 457X414x608mm ( Lxdxh ) * Through Put: Up To 50 Samples / Hour * Only 2Ml Sample Is Required Technical Specifications Technology - Whole View Field Microscopic High - Definition Images Centrifugal Accelerated Sedimentation Ai ( Artificial Intelligence ) Identification Detected Partical Classes - > 11 Items: Rbc; Wbc; Hya; Pat; Epi; Nec; Bac; Yea; Cry; Caoxm; Caoxd; Muc Memory - Max 25000 Results ( Including All Images ) Min.Sample Volume - 2.0Ml Throughput - 50 Samples / Hour Batch Size - Single Sample Tube Cuvette Container - 50Pcs User Interface - 13.3 Lcd With Touch Screen Size - 457 X 414 X 608Mm ( Lxdxh ) Weight - 30Kg Power - 110-240 Vac, 50 / 60 Hz, 200 Va , Fully Automatic Biochemistry Analyzer Technical Specifications Machine Type - Random Access Analyzer Test Speed - 200 Tests / Hr Test Principle - Colorimetric Method, Turbidimetry Test Method - End Point, Fixed Time, Kinetic Sample Unit Sample Tray - 40 Sample Positions Sample Cup Type - Micro Cup And Primary Tube Sample Volume - 2-30?L, Step By 0.1?L Sample Probe - Liquid Surface Detection Stat Sample - Available Sample Barcode -Sample Barcode Reader ( Optional ) Reagent Unit Reagenttray -40 Reagent Positions Reagent Volume - 20-300?L, Step By 1?L Reagent Needle - Liquid Surface Detection Reagent Barcode - Reagent Barcode Reader ( Optional ) Reaction Unit Reaction Tray - 44 Reaction Cuvettes, Perfect Transmittance Cuvette Material - Plastics Rreaction Volume - 150~?L - 330?L Temperature - Peltier Padincubation System Mixing System Mixer - Paddle- Type Mixing, Teflon Coated Optical System Light Source - Halogen Lamp Wavelength - 340Nm, 405Nm, 450Nm, 505Nm, 546Nm, 578Nm, 630Nm, 700Nm Absorbance Range - 0-4.0 Abs Resoultion - 0.0001 Abs Operating System Operation System - Windows 10 Workingconditions Power Supply - Ac 110 / 220V ± 10%, 50 / 60Hz Dimension - 745Mm X 540Mm X530mm Weight - 48.4Kg ( N.W ) * Fully Automatic, Random Access Analyzer With A Through Put Of 200 Tests / Hour * Automatic Washing System * Excellent On Board Refrigeration * Stat Sampling * Dedicated Alarm System * Low Maintenance * Dedicated System Packs Available For All Routine Chemistry & Turbidimetry Parameters. , Electrolyte Analyzer Specification Samples - Whole Blood, Plasma, Serum And Urine Electroytes - Na, K, Cl Measurement Principle - Potentiometry, By Ion-Selective Electrodes Measurement Range - For Whole Blood / Plasma / Serum Na:50 ~ 250Mmol / L, K:I ~ 15Mmol / L, Cl:50~200Mmol / L For Urine ( Diluted To 50% With Distilled Water ) Na:10~ 350Mmol / L, K:I~80Mmol / I, Cl:3~300Mmol / L Measurement Time - About 1 Minute Sample Volume - About 22 ? L Data Storage Volume - 50 Measurements Warm-Up Time - About 1 Minute ( At Room Temperature Of 25°C ) Display - 20 Digirs X 2 Lines Lcd 58Mm Width Built-In Thermal Printer External Output - Rs-232C ( Serial ) Measurement Conditions - Temperature: 10~30°C, Relative Humidity:20~80% ( Non-Condensation ) Power Supply - Ac100~240V 50 / 60Hz , Electric Hydraulic Ldr Table Technical Specifications Overall Dimension ( Buffer To Buffer ) 2165*1010 Mm ( L*W ) Frame Dimension 2070*920 Mm ( L*W ) Mattress Platform Dimension1805*650 Mm ( L*W ) Backrest0 Degree -65 Degree Trendelenburg / Reverse Trendelenburg0 Degree- 25 Degree Height525mm To 892 Mm Safe Working Load 180 Kgs Patient Load Bearing Capacity 140 Kgs Standard Features • Wired Handset Control For Patients • Telescopic Iv Pole With 2 Hooks • Three Section Mattress With Pink Color Laminate • Aluminium Lithotomic Crutches Mounted On Stainless Steelrods ( 1 Pair ) • Dust Protective Base Cover • Polymer Moulded Safety Side Rails • Polymer Moulded Head And Foot Boards • 125 Mm High Grade Synthetic Castors With Central And Directional Locking Mechanism • Four Corner Safety Rubber Buffer Of 125 Mm Diameter Removable Ss Tray • All Ms Parts Pre-Treated And Epoxy Powder Coated Safety Standards • General Safety For Medical Electrical Equipmentiec 60601-1-1 • Emi / Emc Iec 60601-1-2 • General Safety For Medical Bediec 60601-2-52 Electrical Specifications Power In ( Operating Range ) 100 Vac To 240 Vac 50 / 60 Hz, Max 5A Liquid Ingress Protection Ipx6 Electrical Shock Protection Class 1 Degree Of Shock Protection Type B Duty Cycle10% ( Two Minutes For Every Eighteen Minutes ) Add On Accessories • Telescopic Iv Pole With 4 Hooks , Oxytocin Infusion Machine 1. The Equipment Should Have A Programmable Roller Type Peristaltic Pump / Volumetric Pump Technology For Delivery Of Iv Fluids And Blood / Blood Products Ranging Between 0.1 Ml To 999.9 Ml Per Minute. 2. The Equipment Should Have High Levels Of Safety From Air Embolism By Integrating Atleast Two Ultrasonic Air Detection Sensors. 3. Heating Process Should Be Done By An Electromagnetic Induction Heating System. 4. The Equipment Should Have Two Infra –Red Temperature Sensors For Accurate Delivery Of Fluids At 37 Degree Celcius. 5. The Equipment Should Have The Facility To Automatically Purge Air For Removal Of Any Outgassed Air To Prevent It From Entering The Patient Line. No Manual Process Should Be Involved. 6. Programmable To Any I.V.Tubing 7. Suitable For Micro / Adult Infusions 8. Audible And Visual Alarms 9. Keep Vein Open ( Kvo ) 9. Keep Vein Open ( Kvo ) 10. Air In Line Detector 11. Free Flow Protection. 12. The Equipment Should Have Operator Controlled Bolus Infusion Key For Rapid Response In Critical Situations. 13. The Equipment Should Have A Line Pressure Control Sensor For Restriction Of Flow In Case Of Line Occlusion Immediately And Stop The Delivery Of Fluids For Patient Safety. 14. The Equipment Should Have A Recirculate Mode For Pre – Warming Of Fluids During Transport. 15. The Equipment Should Have An Interactive On-Board Lcd Display System Which Displays Information About The Rate Of Infusion, Total Volume Infused, Real Temperature Of Fluids, Line Pressure Etc. 16. The Equipment Should Have An Internal Rechargeable Battery Backup For 5 Hours. 17. Consumables Should Be Universal For All Flow Rates Ranging Between 0.1 Ml To 999.9 Ml Per Minute 18. The Principals Must Give A Certificate That If The Supplier / Vendor Is Changed During The Course Of Guarantee / Warrantee Period , The Principals Would Be Responsible For The Upkeep / Maintenance Of The Quote / Supplied Equipment, Besides Honoring All The Terms And Conditions Of Amc In Letter And Spirit 19. Data Entry Calculator Style Numeric Programming Keyboard 20. Pole Clamp Multi-Function Mounting Clamp 21. Time And Date Settings 22. Accuracy ±3%. 23. Rs232c / Usb / Rs485 Output For Printer, Pc Connectivity And Data Acquisition With Selectable Baud Rate Options May Be There ( Optional ) 24. Spares / Consumables Should Be Available For A Period Of At Least Eight Years After Expiry Of The Guarantee / Warrantee Period. 25. Performance Certificates From Satisfied Customers From Central Govt. / State Govt. / Reputed Private Hospitals Must Be Appended In Respect Of The Quoted Equipment. 26. Warranty : 3 Years & Annual Maintenance Contract : 5 Years After Warranty Respectively , Cervical Cauterisation Unit Super Deluxe Silence Model With On / Off Control • Made With High Quality Hypodermic Needles-Ensures Smooth Flow Of Cryog • Equipped With Specially Designed Silencer –Enables Quitter Operation • Body Made Of Abs Plastic , In Attractive Colours-Aesthetically Appearing • Specially Designed Probes For Different Specific End Users –Enables Wide Us • Attractive Light Weight Carrying Case-Easy Probability Features. This Enables • Cleaning The Inner Hypodermic Needle Will Be Much Easier, Thus Saving Valt • Co2 Gas Can Be Used In The Equipment Very Conveniently, Since Removal Of , Vaccum Delivery Machine , Silicone Vaccum Cup ( Vacuum Silastic Cup With Suction Machine ) Specifications Product Description Silicone Vacuum Cup Is Designed For Birth Assisting. Made Of Silicone Material, The Cup Comes With A Soft Rim Which Is Made To Minimize The Risk Of Trauma To Fetal Head. A Reference-Lime Imprinted Vertically On The Cup For Visual Positioning. A Rigid Shaft With Three Loops Provides Firm Grip. Silicone Vacuum Cup With Metal Release Valve It Is Made Of High Grade Transparent Silicone Rubber, Latex Free & Auto Clavable At 134 Degree Celsius. It Can Be Used With Any Suction Machine Or Gauge & Used Directly With Manual Vacuum Extractor For Delivery. It Is Manual. That’S Why, It Can Be Used Without Electricity.It Is Used To Use In Manual Delivery Specifications: • Available Size: 50, 60, 70 Mm • Color: Blue • Type: Silicone Vacuum Cup With Release Valve • Repeatedly Autioclavable Features: • Chemical Resistant • Durable • High Strength , Fetal Doppler Specification • Light Weight, Handset, Portable • High Resolution Ldc Display, Audible And Visual Alarm • Ultrasound Probe –Solid, Anti-Shock, Durable • Built In Loudspeaker • Support 2 Mhz, 2.5 Mhz, 3 Mhz, 4 Mhz, 8 Mhz Watter Proof Probes • Monitor 12 Seeks Above Unborn Baby’S Blood Wall Pulsate • Ultrasound Probe:Solid And Durable, Anti-Shock, Anti-Falling Down • Ultrasound Frequency 2 / 2.5 / 3 Mhz • Power: Ac 220 V 50 Mhz, Built In 9.6 V Rechargeable Batteries • Power Source: Aa ( 9.6 V Rechargeable ) Batteries, Ac / Dc Adapter • Temperature ( Working ) +50 C ~+40 0C . Humidity ( Working ) : <80% Terms And Conditions : : 1. The Quotation Should Be Addressed To “P , Labour Cot Technical Specifications Overall Dimension - 2165*1010 Mm ( L*W ) Frame Dimension-2070*920 Mm ( L*W ) Mattress Platform Dimension-1805*650 Mm ( L*W ) Backrest -0 Degree -65 Degree Trendelenburg / Reverse Trendelenburg -0 Degree- 25 Degree Height - 525Mm To 892 Mm Safe Working Load - 180 Kgs Patient Load Bearing Capacity - 140 Kgs Standard Features • Wired Handset Control For Patients • Telescopic Iv Pole With 2 Hooks • Three Section Mattress With Pink Color Laminate • Aluminium Lithotomic Crutches Mounted On Stainless Steel Rods ( 1 Pair ) • Dust Protective Base Cover • Polymer Moulded Safety Side Rails • Polymer Moulded Head And Foot Boards • 125 Mm High Grade Synthetic Castors With Central And Directional Locking Mechanism • Four Corner Safety Rubber Buffer Of 125 Mm Diameter Removable Ss Tray • All Ms Parts Pre-Treated And Epoxy Powder Coated Safety Standards • General Safety For Medical Electrical Equipmentiec 60601-1-1 • Emi / Emc Iec 60601-1-2 • General Safety For Medical Bediec 60601-2-52 Electrical Specifications Power In ( Operating Range ) -100 Vac To 240 Vac 50 / 60 Hz, Max 5A Liquid Ingress Protection- Ipx6 Electrical Shock Protection -Class 1 Degree Of Shock Protection - Type B Duty Cycle - 10% ( Two Minutes For Every Eighteen Minutes ) Add On Accessories • Telescopic Iv Pole With 4 Hooks , Bp Apparatus ( Mercury ) , Vein Detector ( Infra Red ) , Digital Audiometer Specification 1. Frequency Range: Air Conduction: 125Hz To 8, 000 Hz With Noise Free Change Over Between Frequencies, Bone Conduction: 250 Hz To 8, 000 Hz 2. System Should Have The Facility For Upgrading To High Frequncy Testing : 8, 000Hz To 20, 000Hz, Intensity Range:- 20Db Hl To Db Hl 3. Accuracy: = 2% For Earphone And = 5% For Bone Vibrator 4. Intensity Range: Air Conduction : 10Db Hl To 120 Db Hl Bone Conduction: 10 Db Hl To 75Db Hl ( Mastoid ) - 10Db Hl To 65 Db Hl ( Forehead ) 5. System Should Have The Facility For Talk Forward, Talk Back, Monitor And Auxilary Intercom 6. System Should Have Maskingfacility With Narrow Band Noise And White Noise 7. The Audiometer Must Have A Directional Gooseneck Microphone For Live Voice Testing And Communication 8. The Audiometer Must Have Integrated Vra Controlslocated Directly On The Control Panel 9. The Audiometer Must Have Light Pipes Surrounding Each Parameter Selection On The Control Panel. All Recording Parameters Must Light Up And Stay Lit Until Changes Are Made In The Test Protocol. In The Event Of Power Failure, The Audiometric Data Collected Will Be Recovered And Displayed When System Is Re-Booted. A Large Easy To Read Color Monitor Mut Be Integrated Into The Control Panel With Flexible Adjustments For Individual Viewing Preferences. 10. The Audiometer Must Have Sound Field Speaker Output Range Options To Include 90 Db Hl 11. System Should Have Facility For Upgrading The Following Tests" I ) . Alternate Binaural Loudness Balance ( Ablb ) Or Fowler Test ( Alt ) - Evaluate Perceived Growth Of Loudness Between Ears - Identify Recruitments Ii ) . Short-Increment Sensitivity Index ( Sisi ) - Present Small Increments Of Intensity Change At Low Sensation Levels Iii ) . Modifications To The Sisi Test. Iv ) . Tone Decay Test ( Tdt ) - Measure For A Rapid " Abnormal Auditory Adaptation" In Response To A Continuous Pere Tone - Isolate Retro-Cochlear Pathology Of The Cn Vii V ) . Monaural Loudness Balance ( Mlb ) Test - Evaluae Perceived Growth Of Ludness Of Two Different Frequencies In The Same Ear Vi ) . Difference Limen Intensity ( Dli ) Vii ) . Difference Limen For Frequency ( Dlf ) Viii ) Pure Tone Stenger Test Ix ) . Hearing Aid Evaluation Ix ) . Speech Stenger Test X ) . Masking Level Difference ( Mld ) Xi ) . Sensorineural Acuity Level ( Sal ) Test-Modification Of The Rainville Method Xii ) . Threshould Equalizing Noise ( Ten ) Test Xiii ) . Quick Sin Xiv ) . Lombard Or Voice Reflex Test Xv ) . Delayed Auditory Feedback Xvi ) . Staggered Spondaic Word Test ( Ssw ) Xvii ) .Doerfler-Stewart Test Xviii ) . Modified Doerfler-Stewart Test Xix ) . Performance Intensity Phonetically Balance ( Pipb ) Test Xx ) . Single & Multi-Syllabic Speech Normative Curve Xxi ) . Automated Speech Intelligibility Index ( Sii ) Determination Xxii ) . Pure Tone Audiometry ( Pta ) Averaging Xxiii ) . Langenbeck ( Tone In Noise ) Test Xxiv ) . Bkb- Sin ( Bamford-Kowal-Bench-Speech-N-Noise ) Test Xxv ) . Bekeys Test Xxvi ) . Behavioral Observation Audiometry ( Boa ) Xxvii ) . Should Have Facility To Control Visual Reinforcement Audiometry ( Va ) Device Xxviii ) . Tangible Reinforcement Operant Conditioning Audiometry ( Troca ) Xxix ) . High Frequency - Monitor Oto-Toxic Effects Of Medical Treatment Plans. - Tinnitus Evaluations 12. System Must Be Able To Perform Recorded Tests: * Use An External Stereo Tape Or Cd Player * Perform Apd Testing * Perform Speech In Noise Testing 13. Built-In Scorer / Timer 14. Mixing / Routing Of Signals To Either Or Both Ears Must Be Possible 15. Must Hold Calibration For Tdh And Bone 16. The Audiometer Must Interface With 7 Electronic Record Solutionsand Each Must Be Capable Of Providing Digital Audiogram 17. Must Be Able To Output Pdf Test Report 18. The Audiometer Must Be Able To Operate As A Standalone Audiometer Without A Pc Connection But Able To Communicate With Computer - Must Have Built - In Display 19. Must Have Facility To Connect Printer Directly With Instrument 20. Lcd Display Of Test Frequencies And Intensity Of Test Along With Graphical Display Of Audiogram 21. Must Be Noah Compatible 22. The System Should Have The Regulatory Standards Such As Iso, Fda, Ce Certificate 23. The System Suppliers Should Have Local Service Support , Screening Oto Acoustic Emission System ( Oae ) System ( Diagnostic Oae ) Specification 1. System Must Be Portable ( Handeld ) 2. System Should Not Weight More Than 180 Grams 3. System Should Have Colur Led Display 4. System Should Have Automabe Operation For Quick And Easy Operation 5. System Should Have Both Dioae And Teoae Testing 6. Frequcncy Range: Dpoae:2, 3, 4, Khz, 63 / 55Db Spl Teoae:1.5 To 4 Khz 83Db Spl 7. System Should Have The Capability To Store Up To 250 Tests On Unit 8. System Should Have Accuracy With Noise Mangement Technology 9. System Should Have Polyetlene ( Pe ) Tube Testing Technology And Data Protection Capability 10. System Should Automatically Start After Ensuring Test Requirements Are Met 11. System Shuld Have The Capability To Transfer The Patient Data Wirelessly To The Desktop Computer 12. System Should Be Capable Of Exporting The Data Into Multiple Formats Likde Pdf, Rtf And Image Files Such As Bmp Gif, Jpeg, Png, Tiff, Emf And Wmf 13. Operating Power:7.4 V Lithiumion 14. System Should Be Charged To 100% Within 4 Hours 15. Results Should Be Sorted By Ar, Testers, Dates And Outcome. Battery 220-240 V, 50 / 60 Hz 16. The Battery Should Have A Line Of 15 Hours On Time 17. The System Should Have Compliance To International Regulatorystandards Lide Ce, Fda, Iso Etc , Endoscope ( Adult & Peadiatric ) Specification 7230 Awa 1. Hopkins® Wide Angle Straight Forward Telescop 0º Enlarged View, Diameter 4Mm, Length 18Cm, Autoclavable Fiber Optic Light Transmission Incorporated, Colur Code: Green 7229 Aa Hopkins® Straight Forward Telescope 0º Enlarged View, Diameter 2.7Mm, Length 18Cm, Autoclavable, Color Code:Green Technical Specification For 0ºendoscope 1. Hopkins Wide Angle Straight Angle Telescope 0º A. Enlarged View B. Diameter 4Mm C. Length 18Cm D. Autoclavable E. Fibre Optic Light Transmission Incorporated F. Color Code Green 2. Hopkins Straight Forward Telescope 0º A. Enlarged View B. Diameter 2.7Mm C. Length 18Cm D. Autoclavable E. Fibre Optic Light Transmission Incorporated F. Color Code Green , Gauze Cutter , Mayos Instrument Trolley , Dressing Table , Electric Motor ( Endomotor ) Specification * Brushless Led Electric Motor With 1:5 Increasing Handpiecewaldent Make ( W-146 ) * Increasing 1:5 Ratio * Internal 4 Water Spray * Import Ceramic Bearing * Clamoing Force:4.0Kg * Air Pressre:0.3 Mpa To 0.35 Mpa * Rotate Speed:10000 To 200000 Rpm / Min *Min Intensity:25000Lux * Min Intensity:25000Lux * Bur Applicable: 1.60Mm * Noise:<60Db * Chuck Type:Push Button * Suitable For Disinfection Of High Temperature Steam At 135 Degree C * Ligh:White Led * 135 Degree C Autoclaved Sterilization ( Only For Micromotor ) , Inta Oral Digital Radigraphy Unitwith Accessories Chairside Digital Image Plate System With Accessories ( Vistascan ) 1. Should Be Able To Use Along With Normal Xray System 2. Should Have Following Component A ) Imaging Plates ( Sizes 0-4 ) B ) Scanner For Imaging Plate C ) Following Accessories Should Be Supplied Along With The Equipment Free Of Cost . Imaging Plates Size 2 ( 3Nos ) , Size 0 ( 2 Nos ) , Size 4 ( 1 No. ) 3. Specification Of Imaging Plate A ) Should Be Flexible And Thin As Film For Simple Positioning B ) Cable Free System C ) Sizes: 5 Sizes Should Be Available Such As Size0: 2*3Cm, Size1: 2*4Cm, Size2: 2*3Cm, Size3:2.7*5.4Cm, Size4: 5.7*7.5Cm. D ) Broader Exposure Time Frame And Wide Grey Scale. 4. Specification For Scanner: A ) Should Have Input / Output Buffer, With Its Cassette Transport System. Table Top Type. B ) Should Read Out And Deletes Upto 6 Images Or More In One Step And Makes The Plate Immediately Available Again. C ) Scanning Time Should Be Less Than One Minute. 5. Desktop Computer Requirements: A ) Dell Or Hp Monitor 21 Inch B ) Intel Processor C ) 4Gb Ddr3 256 Gb Ssd D ) Keyboard And Mouse E ) Windows 10 F ) Ups 6. User Manual For Equipment And Software , Ultrasound For Physiotherapy 1Mh2, 3Mh2, Transelue , Faradie / Electric Stimulator Specification * Faradic+Galvanic Stimulate * Pen Electrodes * Pad Electrodes , Wax Bath Specification * Size ( L13" X W 13" Xh 8.5" ) * Weight ( 11Kg ) - White Old Paraffin Wax *Stainless Steel Sheat *Powder Coated Ms Tank *Ikw Heating Element *Automated Temperature Control *Highly Insulated Double Wall , Traction Table Cervical And Lumbar, , Marine Wheel ( Shoulder Wheel ) Stainless Steel Material
|