Tenders Are Invited For Purchase Of All Types Of Laboratory Supplies And Equipment. 1 Tissue Flotation Bath Application : Used For Histological Section Fda Clearance Or Ce Mark : Yes, (Fda Preferred) Configuration : Bench Top Shape : Round Or Rectangle Capacity : > 2 L Temperature Control : Microprocessor Controlled Temperature Range: Min. 37 C Max. 65 C Corrosion Resistant Material For Durability Thermostat Sensor Inside That Turns Off Slide Dryer : Yes Display : Lcd Or Led Environmental Requirements: The Equipment Suitable For Working In The Climate Conditions Of Iraq In Terms Of Temperature & Humidity Power Requirements : (220-240)Vac,50/60 Hz ,3 Pin (G)Type Plug 1 2,300 2,300 514 2 Immunohistochemistry Staining System Application Automated Slide Stainers For Cytology Or Histology Are Designed To Accept Reagent Test Kits For Several Staining Procedures, Such As Antibody-Based Identification Of Tumor Cell Types And Their Biochemical Markers. Ce Mark Or Fda Clearance Yes Processing Mode Automated , Robotic Transfer ,Random, Continuous, Stat Staining Stations Reagent Positions 30 Reagent Volume, Ml 0.01 Material Plastic , Metal Or Both Or Better Manufacturers Reagents Yes Substitution Yes Slide Carriers Slide Capacity 30 Max Throughput/Hr 60 / 8Hr Slide Dryer, °C Should Be Specified Cycle Control Programmable Yes Number Of Programs 190 Protocol Manual Interrupt Yes Data Management Display Lcd , Touchscreen Preferred Bar-Code Reader Yes Alarms Type Audible Required, Visual Preferred Water Requirements Yes ,If Needed Waste Requirements Yes Computer Interface Yes Power Loss Protect Yes , With Suitable Ups To Complete The Cycle Line Power, Vac 220 -240, 50/60 Hz Environmental Requirements The Equipment Suitable For Working In The Climate Conditions Of Iraq In Terms Of Temperature & Humidity Other Speciication Performs Automated Ihc And Ish,Other To Specified Patient Documentation Proper Windows Based Last Generation Computer With High Capability Software To Perform Programming, Reporting And All Processing Programs) 1 46,000 46,000 10,485 3 Full Automated Coagulation Analyzer Application Coagulation Analyzers Perform A Variety Of Tests To Detect Abnormalities In The Components Required To Complete Normal Blood Clotting. Configuration Bench Top System Capacity 40 Throughput, Samples/Hr Pt Aptt 150 70 Number Of Assays Onboard Simultaneously 16 Sample Type Plasma Sample Size, Ml 3Ml, Variable Test Menu: Aptt,D-Dimer,Fib,Pt,Tt, Other To Be Specified Method Used Photo-Optical, Photo Metric , Other To Be Specified Aptt Incubation Time, Min Sample Time Flag Programmable(Preferred) Or 5 Min. Yes System Features Direct Sampling Closed-Tube Sampling Autosampler Assay Continues While Loading Reagents/Consumables Stat Capability Reagents Refrigerated Onboard Yes Prefered Yes Yes Yes Yes Data Management Display Computer Interface Lis Interface Printer Calibration Bar-Code Reader -Sample -Reagent Color Touchscreen Or Lcd Touchscreen Yes Yes Laserjet,Or Other Automatic Yes Yes Power Consumption, Vac Environmental Requirements 220 -240, 50/60 Hz The Equipment Suitable For Working In The Climate Conditions Of Iraq In Terms Of Temperature & Humidity 1 25,400 25,400 5,686 4 Full Automated Tissue Processor Application Automate The Fixation, Dehydration, Clearing, And Infiltration Of Tissue Specimens To Help Preserve The Integrity Of Their Cellular Components For Light Or Electron Microscopy Configuration Floor Type Processing Mode Stationary Chamber Or Moving Basket Chamber/Beaker Capacity, L 1.5 Specimen Capacity Cassettes 50 Process Steps Fixation, Dehydration, Clearing And Wax Embedding Process Time Control Yes , Should Be Specified In Details Temperature Control Yes Solvent Bath, °C 65 Paraffin Bath, °C 65 Displays Lcd , Touchscreen Reagents From Supplier Preferred ( Open System ) Fume Handling Yes ,Charcoal Or Carbon Filter Power Loss Memory Protection Yes Specimen Protection Yes Alert Indicators Yes , Power Loss, Low Temperature, Low Reagent, Lid Open Data Management Capabilities Yes Ups Yes , 10 Min Line Power, Vac 220 -240 , 50/60 Hz Environmental Requirements The Equipment Suitable For Working In The Climate Conditions Of Iraq In Terms Of Temperature & Humidity 1 47,000 47,000 10,500 5 Microscope Purpose To Provide Magnification And Resolution Of Specimens Under Examination Observation Tubes Type Binocular Eyepieces 10X,15X, Wide Field, High-Eye Point Interpupillary Distance Adjustment ; Mm ( 55 -75),Adjstable. Objectives Magnification (4X,10X,40X,100X) ,Other Should Be Specified Nosepiece Configuration Quadruple Or More Objectives Type Achromatic, Plan Achromatic, Plan Apochromatic ,Or Others Total Magnification (40X-1000X) Contrast Method Brightfield: Yes Darkfieled: Yes Phase: Optional Condenser Type Abbe,Achromatic &/ Or Other Type Light Source Led (Preferred),Halogen, Or Other Stand Focusing Mechanism Moving Stage, Rack And Pinion Coarse, Fine Adjustments Coaxial, Low Mounted, 1 Increments Stage Type Mechanical Or Better Tension Adjustment Coaxial Stage Motion X-Y Numerical Aperture 0.9 To 1.4 Dust Cover Yes Environmental Requirements The Equipment Suitable For Working In The Climate Conditions Of Iraq In Terms Of Temperature & Humidity Power Supply 220-240V,50-60Hz 7 2,250 15,750 503 6 Immunoassay Autoanalyzer Application It Used In Hospital And Clinical Laboratories To Analyze The Drugs And Endogeouse Substances In Biological Fluids (Body Fluid). Configuration Bench Top Processing Modes At Least Two Modes Of The Following Modes Throughput, Max Tests/Hr 70 Sample Capacity 60 Sample Type Serum, Plasma , Other To Be Specified Sample Size, l < 220 Smallest Is Preferred Method Used Chemiluminescence Immunoassay Or Fluroscence Immunoassay(Fia ) , Other To Be Specified Test Menu Endocrine Function ,Thyroid Markers ,Viruses, Or , Other Should To Be Specified. Reagents, Type Refrigerated On Board Liquid, Ready-To-Use Or Other Type According To Manufacturer System Features Liquid-Level Sensing Yes Clot Detection Yes Auto Dilution Yes Auto Calibration Yes Auto Wash Yes Data Management Display Lcd Touchscreen , 15" Quality Control Management Yes Results Stored Yes Computer Interface Yes Printer Yes Bar-Code Reader Yes Line Power, Vac, Hz Backup 220~240 Vac, 50/60 Hz Preferred (Battery Or Ups) Environmental Requirements The Equipment Suitable For Working In The Climate Conditions Of Iraq In Terms Of Temperature & Humidity 1 45,000 45,000 10,000 7 Biological Safety Cabinet Purpose Used To Precisely Control Ventilation From Airborne Particles Produced During Routine Microbiological Procedures Away From The User While Maintaining A Controlled Environment For The Specimen. Configuration Freestanding Or Bench Top Type Class Ii A Yes Inward Airflow, Ft/Min 100 Motor, Hp Adjustable Speed 1 2 Yes Self-Test Yes Adjustable Sash Type Yes Sliding And Hinged Other To Be Specified Inlet/Outlet Valves ( 1 3 ) Optional Drain Opening Yes Electrical Outlets Location 2 Sidewall ,Back Wall Or Front Faring Material Frame Work Area Stainless Steel Stainless Steel Preferred Features Airflow Monitor Alarms Sash Open Airflow Cabinet Light Uv Light Preferred Yes Yes Yes Yes Yes Hepa Filter Yes, 0.3 Micron Particles, 99% Efficient. Line Power 220V, 50Hz, 1-Phase Environmental Requirements: The Equipment Suitable For Working In The Climate Conditions Of Iraq In Terms Of Temperature & Humidity. 1 10,000 10,000 2238 8 Esr Analyzer Applications Used For Determined Erythrocyte Sedimentation Rate(Esr) In The Blood Design Heavy Duty And Compatible Measuring Method Infrared Ray Beam Number Of Reading Channels 10 Through Put 20 Tests Per Hours Sample Volume (Ml) 1.6Ml Reading Time (Selectable) 30 Minutes Loading Pattern Random Access Display Yes Bar Code Reader Yes Printer Yes Stored Patient Results Yes , 200 Test Interface Rs232 For Printer , Host And Bar Code Scanner Analysis Result In Westergren Millimeter Per Hour Temperature Correction Automatic Compensation To 18 Oc Power Requirements 220-240Vac,50-6-Hz Environmental Conditions The Equipment Suitable For Working In The Climate Conditions Of Iraq In Terms Of Temperature & Humidity 2 15,000 30,000 3358 9 Clinical Chemistry Analyzer , Bench Top Application Determine The Concentration Of Certain Metabolites, Electrolytes, Proteins, And/Or Drugs In Samples Of Serum, Plasma, Urine, Cerebrospinal Fluid, And/Or Other Body Fluids. Fda Clearance Or Ce Mark Yes Configuration Bench Type Processing Modes Random Access , Continuous System Capacity 30 Throughput, Max Tests/Hr 200 Sample Type Serum/Plasma , Urine , Optional : Csf Sample Size, l 100 Test Menu, Min To Be Specified By User Programmed Tests Yes User-Definable Tests Yes Method Used End Point, Kinetic, Ise Or Other Optical System Photometric, Spectrophotometric Or Other Light Source Halogen , Tungsten-Halogen Or Other Reagents, Type Liquid Or Other Substitution ( Open Or Closed System ) Yes Refrigerated Onboard Yes System Features Closed-Tube Sampling No Direct Sampling Yes Liquid-Level Sensing Yes Auto Dilution Yes Abnormal Values Flag Yes Auto Verification According To Manufacturer Auto Quality Control Yes Auto Calibration Yes Data Manag Tender Link :
|