Establishment Of Quality Control / Material Testing Laboratory In District Anantnag ( Adv.Cost28.92 Lacs ) - Iss Sieve Sets ( As Per Specifications Of Is:460 ) Iss Gi-Frame Sieve Set. ( Size 30Cm Dia ) A ) 80 Mm B ) 63 Mm C ) 45 Mm D ) 40 Mm E ) 37.5 Mm F ) 26.5 Mm G ) 20 Mm H ) 19 Mm I ) 16 Mm J ) 13.2 Mm K ) 12.5 Mm L ) 11.2 Mm M ) 10.0 Mm N ) 9.5 Mm O ) 6.3 Mm P ) 5.6 Mm Q ) 2.8 Mm R ) 4.75 Mm S ) 3.35 Mm T ) 2.36 Mm ( Complete & Operational In All Respects ) . Purpose Of The Equipment Grain Size Distribution Analysis ( Grading ) Lacation Od Its Use ( Site / Lab ) Field & Lab Use , Precision Infrared Thermometer Digital Non-Contact Infrared Thermometer ( Superior Make ) , With Backlight Lcd Display, Battery Powered, With Minimum Operational Temperature Range Of -20C To 300C ( Or Better ) , Display Resolution Of At Least 0.1 C / F, Suitable Spectral Response, Class-2 Laser Power With Display Hold Feature. ( Complete & Operational In All Respects ) Purpose Of The Equipment Grain Size Distribution Analysis ( Grading ) Lacation Od Its Use ( Site / Lab ) Field & Lab Use , Precision Electronic / Digital Balance, With Dual Power Operation ( Ac / Battery ) Cas: Superior Brand Precision Digital Balance ( 5 Kg ) , Capable Of Measuring 0.5 Gm To 5 Kg With Permissible Error. ( Complete & Operational In All Respects ) Purpose Of The Equipment General Purpose For Weights And Measuremens Lacation Od Its Use ( Site / Lab ) Field & Lab Use , Precision Electronic / Digital Balance, With Dual Power Operation ( Ac / Battery ) Cas: Superior Brand Precision Digital Balance ( 30Kg ) , Capable Of Measuring 1.0 Gm To 30 Kg With Permissible Error. ( Complete & Operational In All Respects ) Purpose Of The Equipment General Purpose For Weights And Measuremens Lacation Od Its Use ( Site / Lab ) Field & Lab Use , Precision Infrared Thermometer Digital Non-Contact Infrared Thermometer ( Superior Make ) , With Backlight Lcd Display, Battery Powered, With Minimum Operational Temperature Range Of -20C To 300C ( Or Better ) , Display Resolution Of At Least 0.1 C / F, Suitable Spectral Response, Class-2 Laser Power With Display Hold Feature. ( Complete & Operational In All Respects ) Non Contact Temperaturemeasurements Lacation Od Its Use ( Site / Lab ) Field & Lab Use , Precision Probe Type Thermometer Digital Contact Type Probe Thermometer ( Superior Make ) , Battery Powered, With Minimum Operational Temperature Range Of -50C To 300C ( Or Better ) , Display Resolution Of At Least 0.1 C / F. ( Complete & Operational In All Respects ) Contact Temperaturemeasurements Lacation Od Its Use ( Site / Lab ) Field & Lab Use , Aggregate Impact Testing Machine ( As Per Specifications Of Is:9377 ) Standard Aggregate Impact Testing Machine For Determination Of Impact Value For Small Size Mineral Aggregates / Rocks. Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Aggregate Impact Value Lacation Od Its Use ( Site / Lab ) Field & Lab Use , Bitumen Binder Centrifuge Extractor ( As Per Relevant Is Specifications / Astm D 2172 ) Manually Operated Bitumen Binder Centrifuge Extractor For Bituminous Mix Up To 1.5 Kg Capacity, With Hand Speed Control, With Filter Paper Discs ( Set Of 500 Sheets ) . Equipmentmustbeofgoodmake / Manufactureand Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Bitumenbinder Extraction Lacation Od Its Use ( Site / Lab ) Field & Lab Use , Consistency Test Apparatus The Test Apparatus Must Be As Per Is: 2720 Part-5, Is: 9259 Relevant Specifications, For Determination Of Consistency ( Liquid Limit ) Of Soils By Casagrande Method. The Apparatus Must Be Manually Operational, With Counter, With I.S / Bs / Astm Grooving Tools, Gauging Block. Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Liquid Limit Of Fine Material ( S425micron ) Lacation Od Its Use ( Site / Lab ) Lab Use , Enamel Ei-Trays: Sampling Purpose Enamel Tray / Plates / Bucket Of Following Minimum Sizes. ( Complete & Operational In All Respects ) Purpose Of The Equipment Material Sorting / Processing Lacation Od Its Use ( Site / Lab ) Field & Lab Use , A ) 250X300 Mm Tray. , B ) 450X600 Mm Tray , Flakiness & Elongation ( Shape Test ) Apparatus As Per Is Specifications / Sp-36, Is:2386 ( Part-1 ) Equipment Must Consist Of Following Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Shape Test Of Aggregates Lacation Od Its Use ( Site / Lab ) Field & Lab Use , A ) Thickness Gauge Manufactured From Heavy Gauge Steel With Is-Certification Stamp. , B ) Length Gauge Manufactured From Superior Steel, Mounted On A Hardwood Base, With Is-Certification Stamp. , Universal Penetrometer With Penetration Cone & Bitumen Penetration Kit ( Is: 1448 ( Part 60 ) , Astm: D 937, Ip: 179, Bs:4698, Astm: D 217, Ip: 50, Iso: 2137, En:1426, 13179-2 ) Equipment Must Consist Of Following Replicable Parts A ) Universal Penetrometer With Adjustable Head And Display ( 1 No ) . B ) Penetration Cone For Determination Of Consistency Of Lubricating Grease And Oils ( 1 No ) . C ) Bitumen Penetration Kit Consisting Of Penetration Needle, Copper Transfer Dish, Aluminum Containers ( 1 No ) . D ) Penetration Test Cone For Soils, With Cups ( 1 No ) . Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Bitumen Quality Evaluation Lacation Od Its Use ( Site / Lab ) Field & Lab Use , Softening Point Apparatus ( As Per Is:1205 Ring And Ball Type ) : Equipment Must Be Capable For Determining Temperature At Which A Sample Of Bituminous Specifically Loaded Will Achieve Certain Degree Of Softening. Apparatus Must Have Arrangement For Magnetic Stirring Of Water Bath, Adjustable Heating System With Digital Display Of Temperature Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Bitumen Testing Lacation Od Its Use ( Site / Lab ) Lab Use , Cleveland Flash ( Open ) & Fire Point Apparatus. ( As Per Specification Of Is:1448, P:69, Is: 73-2013 ) Equipment Must Be Capable For Determining Flash & Fire Point Of Bitumen. The Flash Cup Must Be Made Of Brass With Insulated Handle. Equipment Must Have A Metal Heating Plate Electrically Operated With Energy Regulator & Gas-Jet Assembly ( Complete In All Respects With All Optional Accessories ) . Purpose Of The Equipment Bitumen Testing Lacation Od Its Use ( Site / Lab ) Lab Use , Absolute ( Dynamic ) & Kinematic Viscosity Apparatus ( As Per Is Specifications 1206 Part-Ii & Part-Iii, Is:73-2013 ) Equipment Must Comprise Of Following A ) 2-No Viscometertubes ( Cannon-Manning Vacuum Viscometer ) Made Of Borosilicate Glass With Size No:12 ( Is: 1206-Part-Ii ) For Determination Of Absolute Viscosity In The Range Of 300 To 8000 Poise At 60 C, Along With Calibration Certificate. B ) 2-No Viscometer Tubes ( Cannon-Fenske Viscometer ) Made Of Borosilicate Glass With Size No:350 ( Is: 1206-Part-Ii ) For Determination Of Kinematice Viscosity In The Range Of 30 To 500 Cst At 135 C, Along With Calibration Certificate. C ) 1-No Oil Free Vacuum Application System With 4- Lines, With Vacuum Range Up To 300Mm Of Hg, And Least Measurable And Maintainable Level Of ±0.5Mm Of Hg. D ) 3-No Mercury In Glass Tube Type Thermometer With Range Of 0C To 150C, Scale ± 0.2 C ( As Per Is: 1206-Part-Ii ) E ) 1-No Viscometer Silicon Bath, With Uniform Temperature Maintenance System, Using Accurate Pdi Temperature Controller With Accuracy Of ±1 C, For Conduction Of Absolute & Kinematic Viscosity Test On Bituminous And Cut-Back Materials By Vacuum Capillary Method At Specified Temperatures. ( Complete & Operational In All Respects With All Optional Accessories ) . Purpose Of The Equipment Bitumen Viscosity Testing Lacation Of Its Use ( Site / Lab ) Lab Use , Thickness Gauge Ms Thickness Gauge With Minimum Gauging Depth Of 150Mm ( Complete & Operational In All Respects ) Purpose Of The Equipment Thickness Of The Paving Mix Lacation Od Its Use ( Site / Lab ) Lab Use , Hydrometer: As Per Is Specifications / Sp-36, Is:2720 ( Part-4 ) , Is:3014. ( For Soils / Fines With >10% Passing 75 Micron Sieve ) Soil Hydrometer Made Of Superior Clear / Transparent Glass Of Uniform Clarity Throughout The Upper Density Scale End. The Density Scale Range Must Be 0.995 To 1.30 G / Cc ( G / Ml ) At 27C, With Least Count Of 0.0005 G / Cc ( G / Ml ) . There Shall Be No Abrupt Changes In The Cross Section Of The Hydrometer, Such As Will Hinder Cleaning Or Permit Air Bubbles To Be Trapped. The Hydrometer Shall Have Maximum Permissible Scale Error Of Plus / Minus One Scale Division. ( Complete & Operational In All Respects ) Purpose Of The Equipment Specific Gravity Of Suspensions Lacation Of Its Use ( Site / Lab ) Lab Use , Soil Pycnometer ( As Per Ref. Standard Is: 2386 ) ( For Determination Of Specific Gravity Of Clays, Sands, And Gravels Of Grain Size <10Mm. ) Equipment Must Consist Of 1-Kg / 1-Liter Superior Glass Bottles, With Bored Brass Cone Stopper, With Locking Ring And Rubber Seal. ( Complete & Operational In All Respects ) Purpose Of The Equipment Specific Gravity Fine Aggregates Lacation Of Its Use ( Site / Lab ) Lab Use , Electric Hot Air Oven ( Reputed Make ) Superior Laboratory Electric Oven, Thermostatically Controlled Or With Digital Controller Cum Indicator With Safety Alarm. It Must Be Double Walled, With Outer Body Made Of Mspowder Coated & Inner Made Of Stainless Steel. It Must Have Provision For Horizontal Ribs For Adjusting Trays At Any Height. Equipment Must Have Side Heating / Air Circulating Fan, To Distribute The Temperature Range 50C To 250C ± 1C, With Air-Ventilators. The Size Of Oven Must Be 450X450x450 Cm, With Size Tolerance ± 10Mm. Equipment Must Operate Under 220 V ( ±5% ) , 50Hz, Single Phase Ac Supply Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Sample Preparation / Drying / Moisture Determination Lacation Od Its Use ( Site / Lab ) Lab Use , Concrete Specimen / Sampling Moulds As Per Relevant Is-Specifications ( Is 10086 ) Mold For Preparing Concrete / Cement-Mortar Specimens Of 150Mm Sizes Of Cubical Shape, With Isi Certification Mark. Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Concrete Sample Prearation Lacation Od Its Use ( Site / Lab ) Lab Use , Table Mounted Marshall’S Stability Apparatus ( As Per Is / Astm D-1559, D-6927 Specifications ) Equipment Must Consist Of Marshals Stability Loading Frame 50Kn Capacity ( With Proving Ring ) , Single Speed Withplaten Speed Of 50.8Mm / Min ( Precise Speed ) , Suitable To Operate On 220V, 50 Hz, Single Phase Ac-Supply, Limit Switch Protection For Both Upward And Downward Travel, Following Must Be Supplied With The Apparatus; A ) Marshall''s Steel Compaction Hammer, Weight 4.5 Kg, With A Free Fall Of 457Mm ( 2-No ) . B ) Compaction Moulds ( 10.16 Cm Dia And 7.6 Cm Height, For 25.4Mm Maximum Nominal Aggregate Size ) Of Steel Cylindrical, With Individual Extension Collar And Base Plates ( 3-No ) C ) Hydraulic Sample Eject ( 1-No ) . D ) Sample Breaking Head With Load Transfer Bar And Flow Measurement Arrangement Using Dial-Gauge. E ) Compaction Pedestal Comprising Of Steel Plate Capped Wooden-Post. Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Marshalls Test And Mix Design Of Bitumious Paving Mixes Lacation Od Its Use ( Site / Lab ) Lab Use , Water Bath ( Reputed Make ) Water Bath Thermostatically Controlled Or With Digital Controller Cum Indicator, Doubled Walled, Inner Chamber Made Of Non-Rusting / Stainless Steel, Outer Body Made Of Ss And Minimum Dimensions ( 425X325x100 ) Mm Or Higher, With Temperature Range Of 5C To 100C With Precision Of ±0.5C, Run By 220 V ( ±5% ) , 50Hz, Single Phase Ac Supply. Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Assorted Tests Lacation Od Its Use ( Site / Lab ) Lab Use , Motorised Sieve Shaker Equipment Must Consist Of Motorized Sieve Shaker For Sieving Dry Granular Or Powdered Materials / Soils. It Must Accommodate Up To 8 Sieves Of 20 Cm Dia. The Equipment Must Be Geared Motor Driven Of Suitable Hp. Direction Of Inclination Of Sieve Table Must Change Progressively In Clock-Wise Direction, With Both Gyratory And Tapping Motion Of Table. Equipment Must Be Controlled By A Proper Switching Device With Timer Facility And Emergency Stop / Start Button. Equipment Must Run By 220 V ( ±5% ) , 50Hz, Single Phase Ac Supply. Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Assorted Tests Lacation Od Its Use ( Site / Lab ) Lab Use , Buoyancy Balance, With Dual Power Source ( Ac-220V Sp / Battery ) : Apparatus Shall Consist Of Setup With Electronic Balance Capable Of Measuring Up To At Least 25Kg Sample, With Arrangement Below For Suspending The Aggregate / Concrete Specimen Below The Balance, Inside A Water Tank. The Water Tank Position Must Be Adjustable ( Mechanically ) For Proper Suspension. Complete In All Respects With All Optional Accessories ) . Purpose Of The Equipment Multi Purpose Lacation Od Its Use ( Site / Lab ) Lab Use , Vicat Apparatus For Cement As Per Relevant Is-Specifications ( Is:5513 ) : The Apparatus Must Be Complete For Determination Of Consistency Of Standard Cement Paste And Setting Times Of Cement. The Apparatus Must Have I.S Certification And Shall Comprise Following A ) Sturdy Frame With Movable Plunger, With Cap At The Top. B ) 40Mm Height Vicat Mold In The Form Of Cone Frustum With 60Mm Top Dia And 70Mm Bottom Dia. C ) Glass & Steel Base Plate. D ) Initial & Final Setting Time Needles E ) Consistency Plunger. Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Consistency Cement Initial And Final Setting Time Lacation Od Its Use ( Site / Lab ) Lab Use , Slump Test Apparatus For Concrete As Per Relevant Is-Specifications ( Is:7320 ) : The Apparatus Must Be Complete For Determination Of Slump Of A Fresh Concrete, As A Measure Of Its Consistency For Maximum Nominal Size Of 38.0Mm Aggregates. The Apparatus Shall Comprise Of Following A ) Slump Cone With Top Dia Of 100Mm, Bottom Dia Of 200Mm And Height Of 300Mm. B ) Base Plate With Clamping Arrangement And Swivel Handle. C ) 60Cm Long, 1.6Cm Dia, Graduated Tamping Rod With One End Rounded, Having Graduation Up To 150Mm, In Steps Of 5.0Mm. D ) Consistency Plunger. Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Workability Of Concrete Lacation Od Its Use ( Site / Lab ) Field & Lab Use , Digital Compression Testing Machine, Ctm 2000Kn, Dual Gauge, As Per Relevant Is-Specifications ( Is:14858-2000, Is: 516 ) : The Ctm Equipment Must Be Sturdy With Steel Welded Frame Capableofwithstandingcyclesofloading&Unloading Without Distress And Shall Be Operational By 220 V ( ±5% ) , 50Hz, Single Phase Ac Supply. The Ctm Must Adhere To Following Requirements; A ) Dual Gauge For Measurement Of Load With Varied Capacity Of 500Kn & 2000Kn. B ) Maximum Load Capacity Of 2000Kn, With Least Count Of 0.1Kn. C ) Finished Bottom Platen ( At Least 222Mm ) Over Leveled Hydraulic Ram, With Piston Dia Of At Least 222Mm And 50Mm Stroke. D ) Finished Top Platen With Spherical Seating For Adjusting To Sample Irregularity And Alignment. E ) Metal Safety Door With Perspex / Wire-Grid Window And Overload Tripping Device. Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) Purpose Of The Equipment Compressive Strength Of Mortar Bricks Rocks Tiles Lacation Od Its Use ( Site / Lab ) Lab Use , Los Angles Abrasion Testing Machine With Abrasive Charge ( As Per Is Specifications / Ref. Standard: Is-10070 ) A ) Equipment Must Consist Of Los Angles Abrasion Testing Machine For Determination Ofwear Resistance Of Small Size Mineral Aggregates And Crushed Rocks. Equipment Must Have A Hollow Cylinder With Sturdy Frame, Detachable Shelf For Catching Abrasive Charge. Drum Speed Of At Least 30Rpm, Run By 3-Phase Electric Motor Suitable For Operation On 415 ( ±3% ) 50Hz Ac Supply. B ) Abrasive Charge Consisting Of Set Of 12 Hardened Steel Balls Of 48Mm Dia. C ) Digital / Manual Controller. ( Complete & Operational In All Respects With Aboveorbetterspecificationsandwithalloptional Accessories ) Purpose Of The Equipment Abrasion Tests On Aggregates Lacation Od Its Use ( Site / Lab ) Lab Use , Soil Compaction Apparatus / Cbr Moulds As Per Specifications / Ref. Standard Of Is:10074, Is:2720 ( Part 7 ) , Is:2720 ( Part 8 ) , Is:9198, Is: 2720 ( Part-16 ) , Is:9669. Equipment Must Consist Of Following For Performing Tests To Determine Density Moisture Relations For Soils. ( With Hammers ) ( Complete & Operational In All Respects With Above Or Better Specifications And With All Optional Accessories ) Purpose Of The Equipment Compaction Test & Cbr Test On Soils / Gsb Lacation Of Its Use ( Site / Lab ) Lab Use , A ) Standard Compaction Apparatus ( Light Compaction / Standard Proctor ) Consisting Of 1000Ml Volume Gun-Metal Mould , 100Mm Dia ( Id ) , 127.3Mm Height, With Base Plate Collar And Hammer Of 2.6Kg With 310Mm Fall. , B ) Modified Compaction Apparatus ( Heavy Compaction / Modified Proctor ) Consisting Of 2250 Ml Volume Gun-Metal Mould , 150Mm Dia ( Id ) , 127.3Mm Heigh , C ) Cbr Moulds ( Gun Metal 150Mm Id, 175Mm H ) , Complete With Perforated Base Plate, Extension Collar, Circular Metal Spacer Disc, Annular Metal Weight, Slotted Metal Weight, Perforated Plate With Adjustable Stem And Lock Nut, Metal Tripod For Settlement Dial Gauges. , Field Density Cores Field Density Core Cutters ( Is: 2720 Part 29 ) : The Equipment Set Must Consist Of Following Replaceable Parts ( Complete & Operational In All Respects ) Purpose Of The Equipment Measurement If Soil In Situ Density Lacation Of Its Use ( Site / Lab ) Field Use , A ) Cylindrical Core Cutter 150Mm Dia X 300Mm Long, With Steel Dolly 25Mm High ( Minimum ) And 150Mm Dia, Fitted With A Lip, To Enable It To Be Located On Top Of The Core- Cutter. , B ) Rammer With Steel Rod / Handle. , Laboratory California Bearing Ratio Test Apparatus ( Is:9669, Is: 2720 Part Xvi ) , Equipment Mustconsist Of 50Kn Capacity ( 5000 Kgf ) Motorized, 3Speeds Loading Frame, With Strain Rate Of 1.5, 1.25 And 2.5Mm / Min. Equipment Must Include Proving Ring, 50Kn Compression Type With Mechanical Displacement Measurement Dial Gauges ± 25Mm Travel. Machine Must Be Suitable For Operation On 220 V, 50 Hz, Single Phase, Ac Supply. ( Complete In All Respects ) Purpose Of The Equipment Cbr Test Lacation Of Its Use ( Site / Lab ) Lab Use , Concrete Mixer ( Pan Type ) , Equipment Shall Consist Of Small Pan Type Mixed With Minimum 40.0 Liters Capacity For Mixing Concrete In Fresh State ( Dry Or Wet ) With Maximum Aggregate Size Of 20Mm. The Equipment Must Be Operational On Single-Phase / 3- Phase Ac-Supply 220 / 415V± 2%, 50 Hz. ( Complete In All Respects With Optional Accessories ) . Purpose Of The Equipment Mix Design Of Concrete Lacation Of Its Use ( Site / Lab ) Lab Use , Field Density Equipment Using Sand Replacement Method ( Is: 2720 Part 28 ) : The Equipment Set Must Consist Of Following Replaceable Parts. A ) Sand Pouring Cylinder Fitted With Conical Funnel And Shutter, Capacity 3 Litre. ( 1-No ) B ) Cylindrical Calibration Container 100Mm Id X 150Mm Height ( 1-No ) . C ) Metal Tray Size 30 X 30 X 4Cm With 10Cm Central Hole ( 1-No ) . ( Complete In All Respects With All Accessories ) . Purpose Of The Equipment Measurement If Soil Insitu Desity Lacation Of Its Use ( Site / Lab ) Field Use , Pavement Dynamic Cone Penetrometer ( As Per Standard Specifications ) :- The Equipment Consist Of The Following Replaceable Parts :- A ) Top And Bottom Rod For Continuous Measurements Up To A Depth Of 800Mm And 1200Mm ( 1-No ) . B ) Handle ( 1-No ) C ) Hammer ( 8Kg Drop Hammer Through Variable Height With Maximum Up To 575Mm ) 1-No D ) 1M Scale ( Ss Engraved 1-No ) E ) Anvil ( 1-No ) . F ) 60 0 Cone ( 12-No ) ( Complete In All Respects With All Optional Accessories ) . Purpose Of The Equipment Measurement If Soil Insituconsistency / Desity / Cbr Lacation Of Its Use ( Site / Lab ) Field Use , Direct Shear Apparatus Purpose Of The Equipment Lacation Of Its Use ( Site / Lab ) Lab Use , Vane Shear Apparatus Purpose Of The Equipment Lacation Of Its Use ( Site / Lab ) Lab Use , Schmidt Rebound Hammer Digital Purpose Of The Equipment Lacation Of Its Use ( Site / Lab ) Field Use , Miscellaneous Items / Glassware / Consumable Items / Safety. , A ) Superior Quality Borosilicate Bottles Of 50Ml Capacity, With Capillary Bored Glass Stopper, For Determination Of Specific Gravity Of Soil / Bitumen / Powders Etc. Purpose Of The Equipment Specific Gravity Lacation Of Its Use ( Site / Lab ) Lab Use , B ) Heat Resistance Safety Glove Of Superior Quality. Purpose Of The Equipment Safty Lacation Of Its Use ( Site / Lab ) Fieldlab Use , C ) Natural High Grade Pigmented Heavy Duty Latex Hand Gloves Of Medium Size. Purpose Of The Equipment Safty Lacation Of Its Use ( Site / Lab ) Field Lab Use , D ) Medium Size Ss Scoops / Trowels. Purpose Of The Equipment Mix Sampling Lacation Of Its Use ( Site / Lab ) Field & Lab Use , E ) Superior Quality And Make Heavy-Duty Led Flash Light With Chargeable Battery. Purpose Of The Equipment Operation At Use Lacation Of Its Use ( Site / Lab ) Field & Lab Use , F ) Superior Quality Masks. Purpose Of The Equipment Safty Lacation Of Its Use ( Site / Lab ) Filed & Lab Use , G ) Knife / Spatula. Purpose Of The Equipment Sample Lacation Of Its Use ( Site / Lab ) Field & Lab Use , H ) Trichloroethylene. Purpose Of The Equipment Bitumen Quality Lacation Of Its Use ( Site / Lab ) Field &Lab Use , I ) Glass Beaker 1Liter Capacity. Purpose Of The Equipment Stripping Test Lacation Of Its Use ( Site / Lab ) Field & Lab Use , J ) General Tool Box Purpose Of The Equipment General Use Lacation Of Its Use ( Site / Lab ) Field &Lab Use , K ) Ss Container ( 1-Liters ) With Lids Purpose Of The Equipment Bitumen Simple Lacation Of Its Use ( Site / Lab ) Field & Lab Use , L ) Disposable Aluminum Foil Container Purpose Of The Equipment Mix Sampling Lacation Of Its Use ( Site / Lab ) Field & Lab Use , M ) Traffic Diversion Cones ( Delineators ) Purpose Of The Equipment Safety Lacation Of Its Use ( Site / Lab ) Field & Lab Use , N ) Ss Moisture Containers With Lids Purpose Of The Equipment Moisture Test Lacation Of Its Use ( Site / Lab ) Field & Lab Use , O ) Solvent For Bitumen Extraction Purpose Of The Equipment Bitumen Content Lacation Of Its Use ( Site / Lab ) Field &Lab Use
|