Tenders Are Invited For Price registration for eventual and future hiring of legal entity to lease hospital ... in Brazil
Tender Notice
TenderID
54861655
Tender Brief
Tenders Are Invited For Price registration for eventual and future hiring of legal entity to lease hospital equipment for physiotherapy and oxygen therapy, with preventive maintenance, corrective and operational training, without exclusive dedication of laor, to meet the physiotherapy services of the State Department of Health Ma, in court demands and homeciliary care services (homecare), according to conditions, quantities and requirements
1 LEASE MAINTENANCE OF PERMANENT EQUIPMENT HOSPITAL MEDICAL EQUIPMENT SERVICE FOR INVASIVE AND NON INVASIVE VENTILATION, PORTATEL FOR HOME Care, LIFE SUPPORT, ADULT AND PEDIATRIC ACCOMPANYMENT OF ALL REQUIRED EQUIPMENT (including disposale inputs) to The perfect functioning of the preventive and corrective maintenance apparatus for noninvasive and invasive, portale ventilation with independent gas source on pressure (network), with pressure control or volume control, for patients with weight aove 5kg capacity Provide controlled volume ventilation (ACCVSIMV) or controlled pressure (CPAPsSTPTTPSIMV) through noninvasive or invasive methods with advanced leakage compensation for patient prescription change option Circuit availaility andor with exhaustive valve GUARANTEE MEDIUM VOLUME PRESSURE SUPPORT: IPAP (4 to 50 cmH2O) EPAP (0 to 25 cmH2O) PEEP (0 to 25 cmH2O) Pressure support (0 to 30 cmh2O) Middle volume (50 to 2000ml) With more specifications in the Differentiated Reference Treasury Term: Applicaility Decree 7174: Non Applicaility Preference Margin: Non Quantity: 12 Supply Unit: Unit2 Rental Maintenance of Permanent Equipment Rental Service Level with volume guarantee humidifier, trachea and adapters (non invasive, inale ventilation equipment for home care), with preventive maintenance and corrective and non invasive ventilation, inale, two level flow generator (pressure support with Warranty of average volume y oscillation of inspiratory pressure) should contemplate the minimum pressure ventilatory modes S, ST, T and PC (spontaneous, spontaneouscontrolled, controlled and controlled pressure), ventilates patient from 18kg Automatic compensation in the presence of leakage up to 60 Lmin Ventilatory adjustments must allow at least 4 to 30 cm H2O IPAP intervals, EPAP of 4 to 25 cm H2O, CPAP from 4 to 20 cm H2O current volume from 200 to 1500ml respiratory rate from 0 to 30 rpm, inspiratory time from 05 to 3 seconds, lifting time from 100ms to 300ms Automatic sensitivity adjustment Monitoring: Pressure current volume leak With more specifications in the Term of Reference Differentiated: Applicaility Decree 7174: Non Applicaility Preference Margin: Non QUANTITY: 12 UNIT UNIT: UNIT3 LEASE MAINTENANCE OF PERMANENT EQUIPMENT Hiring Legal Hiring Service for hospital medical equipment Oxygen concentrator, Portale 03 Oxygen offering modes for air and terrestrial transportation (approved y the National Civil Anac Agency or American Aviation Agency FAA), with preventive maintenance and concentrating corrective capale of eing used continuously at home, institutions and During trips and any air displacement or terrestrial maximum weight of 5 oxygen from 87 to 96 accompanied y transport cart and rechargeale lithium attery, with approximate autonomy of 03 hours, with a reserve attery, which allows flight autonomy s up to 06 hours Rapid recharge that can e done from a power source CA or a maximum noise level of 50 d Included Items: Protective ag Accessories ag DC AC Food Cales 12V Output Disposale Inputs (10 nasal catheters) Instruction ManualUser In Differentiated Treatment: Applicaility Decree 7174: Non Applicaility Preference: Non QUANTITY: 12 UNIT UNIT: UNIT4 Leasing Maintenance of Permanent Equipment Hiring Service for Legal Entities to Lind Hospital Medical Equipment Auxiliary cough, with preventive maintenance and corrective cough assistant device that helps in the expectoration of secretions in patients who cannot cough and expel into form Voluntary The elimination of secretions in patients who cannot cough is often done through invasive methods, and unfortunately these aspirations are uncomfortale, as well as causing infections and tissue injury increases the expiratory flow of cough and reduce Recurring respiratory infections, thanks to the integrated algorithm, which aids the device configuration and synchronizes with the patient, promoting comfort and compliance Differentiated: Applicaility Decree 7174: Non Applicaility Preference Margin: Non Quantity: 1
Contact Information
Address
Endereo:Av. Carlos Cunha, Sn, Calhau - - So Lus (MA)Telefone:Fax:
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 54861655
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.