Development Of Gummat Bazaar At Jammu---- 1 Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge:All kinds of soil 2 Earth work in excavation by manual/mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres 3 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8(1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 4 Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts andstruts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) (For Flooring) 5 Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts andstruts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above Plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more 7 Centering and shuttering including strutting, propping etc. and removal of form work forFoundations, footings, bases for columns 8 Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. 9 Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. 10 Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls under 20cm wide 11 Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth andstring courses etc. 12 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 13 Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:3:6 or richer mix (i/c equivalent design mix) 14 Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge In cement mortar 15 Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of G.S. Sheet 16 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead. 17 Engagement of skilled labour/fitter for removal of shutter of shop 18 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 19 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) 20 Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level 21 15mm Cement plaster on the rough side of single or half brick wall of mix:1 : 6 ( 1 cement : 6 fine sand) 22 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2mm thick 23 Finishing wall with water proofing cement paint of required shade New work Two or more coats) applied @ of 3.84 Kg/10Sqm 24 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour Two coats 25 Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigments etc. 26 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaftwith brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 27 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. completeHot finished welded type tubes 28 Steel work welded in built up sections/framed work, including Cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 29 Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 30 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) 31 Providing and fixing tiled False Ceiling of specified materials of size 595x595mm in true horizontal level suspended on inter locking metal gridof hot dipped galvanized steel sections (galvanized @ 120 gms/sqm bothside inclusive ) consisting of main “T” runner with suitably spaced jointsto get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spacedbetween main “T” at 600mm center to center to form a grid of 1200 x600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size24x24x0.30mm and laying false ceiling tiles of approved texture in thegrid including, wherever, required cutting/making, opening for serviceslike diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dashfasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along size85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick fully Perforated Gypsum Board tile made fromplasterboard having glass fiber conforming to IS: 2095 part-I, of size 595x595 mm, having perforation of9.7x9.7 mm at 19.4 mm c/c with center borders of 48mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. 32 Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion 75 mm diameter 33 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 34 Providing and fixing of UniStone or equivalent glass reinforced concrete (G.R.C) exterior paving tiles in "Cobblestone" finish in approved shade in sizes of 152mm x152mm. The thickness of the tiles should range between 20 to 22 mm, allowing variance of ± 5mm in accordance with IS: 1237-1980. The tiles should be made with M40 Grade concrete mix design having ’43’ grade Portland cement, reinforced with Alkali Resistant glass fiber and the pigmentation should be done with exterior grade synthetic inorganic iron oxide pigments manufactured by ‘BAYFERROX (Germany)’ or equivalent with high vibration technology. The pigmentation should be homogeneous and in accordance with British standard BS EN 12878:1999. The other additives should be fine washed graded quartz, super plasticizers and integrated water proofers agents and others. The tiles should be produced with high vibratory technology and their concrete mix design compressive strength should be of M-40 grade@28days. The top surface of the tiles should be treated with acrylic lacquer resulting in top surface water absorption of less than 1% and water absorption of less than 8% by 24 hours immersion method.The beds where tiles are to be laid should be clean, debris free, wet and mopped. The tiles should be laid PCC Concreting with cement mortar of 20mm thickness made with (1:3) Cement : Coarse Sand, adequate grooves should be maintained between 8-10mm using spacers and pointing work to be done with 1:3 ( Cement : Fine Sand) mix. 35 Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour or shade.(Area of slab upto 0.5 sqm) 36 Supply and filling of good earth in layers including compaction, consolidation, watering ramming, loading and unloading complete job 37 Grassing with selection no. 1 grass including watering & maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing including supplying of good earth if needed (the good earth shall be paid separately.) with grass turf 38 Plantation of rotary with Green Hedge 39 Plantation of rotary with Ixora Shrub 40 Plantation of rotary with Boxwood Bonsai 41 Plantation of rotary with Ficusfied Green plant 42 Plantation of rotary with PseudoPhoenix Vinifera/Cherry Palm 43 Plantation of rotary with Bougainvillea Pink Cluster 44 Plantation of rotary with Canna Lilly 45 Plantation of rotary with Begonia 46 Plantation of rotary with Hibiscus Red Plant 47 Plantation of rotary with Indian Rose Red/White 48 Dismantling of old toilet complex incl septic tank and disposal of dismantling material from site of work. 49 Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. 50 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 51 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand) 52 Providing & laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete 53 Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) 54 Extra for half Brick masonry in superstructure above plinth level upto floor V level 55 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal siz 56 Providing andlaying 12mm thick Cement plasterin mortar mix 1:4 ( 1 cement : 4 fine sand) 57 Providing andlaying 15mm thick Cement plasterin mortar mix 1:3 ( 1 cement : 3 fine sand) 58 Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design Inside dimensions 500x700 mm and 45 cm deep for single pipe line with one or two inlets 59 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete In all colours, shades, except White, Ivory, Fume Red Brown 60 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 61 Providing and fixing of aluminum frame & shutter incl.PVC & glass pans complete 62 Providing and fixing of Exhaustfan standard quality with accession complete 63 Providing and fixing of0.5 H.P electric mortar for Lifting of water to over head tank 64 Providing and fixing in position P.V.C water tank with lockable cover of approved brand incl. inlet/outlet and overflow connection complete 65 Providing and fixing of electric fitting with copper wire along switch boardpiano type switch connected Conduit & electric bulb complete 66 Providing and fixing of vitreous squatting pan Orissa Pattern (580x440mm) white shade incl. joining to the trap with 1 cement 1 sand mortar with P.V.C cistern complete 67 Providing and fixing of vitreous pan English pattern white shade incl. P.V.C cistern complete 68 Providing and fixing of vitreous wash hand basin with Pedestrian white shade incl. 15mm c.p brass pillar tap complete. 69 Providing and fixing of 40mm dia C.P short shunk 70 Providing and fixing of a range of 3 urinal of vitreous bowls type urinals flat back pattern 580x380x350mm white shade complete 71 Providing and fixing of 40mm dia waste pipe PVC 72 Providing and fixing of P.V.C connection for wash hand basin & urinals. 73 Providing and fixing of angle value C.P brass for w.hand basin & urinals 74 Providing and fixing of c.p brass bib cock for W.C.S.& Bath 75 Providing and fixing of P.V.C floor trap 76 Providing and fixing of C.P grating 100 mm dia 77 Providing and fixing of C.P. brass towering 78 Providing and fixing of beveled edge mirror mounted on 6mm ply /hard board 79 Providing and fixing of soap dish C.P brass. 80 Providing and fixing of hanger for bathrooms 81 Providing and fixing of P.V.C supreme (ISI) pipe for disposal of waste water and night soilfrominside complete to septic tank and soakage pit. 150mm 82 Providing and fixing of P.V.C supreme (ISI) pipe for disposal of waste water and nightsoilfrominside complete to septic tank and soakage pit. 110mm 83 Providing and fixing of P.V.C supreme (ISI) pipe for disposal of waste water and nightsoilfrominside complete to septic tank and soakage pit. 75mm 84 Providing and fixing of P.V.C supreme (ISI) plan bend 100 mm dia 85 Providing and fixing of nominal bore G.I pipe line to walls/ceiling and floor incl. cost of G.I fitting and required testing and making good the same 15mm dia 86 Providing and fixing of nominal bore G.I pipe line to walls/ ceiling and floor incl. cost of G.I fitting and required testing and making good the same 20mm dia 87 Providing and fixing of C.P brass stop cock of G.I pipes incl. cutting and retreating complete 20mm dia 88 Wiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mmFRLS PVC insulated copper conductor single corecable etc as required. 89 Wiring for circuit/submain wiring along with earth wire with the following sizes of HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required from Distribution board to the first switchboard 2X2.5 sqmm. + 1X1 sqmm earth wire 90 Wiring for circuit/submain wiring along with earth wire with the following sizes of HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required from Distribution board to the first switchboard 2X4 sqmm. + 1X4 sqmm earth wire 91 Supplying and fixing following modular switch/ sockets of legrand myrius/ schneider opale/panasonic vision range or equivalent brand as approved by the Engineer-in-charge complete in all respects with face plates etcon the existing modular plate & switch box including connectionsas required 15/16 amps switch 92 Supplying and fixing following modular switch/ sockets of legrand myrius/ schneider opale/ panasonic vision range or equivalent brand as approved by the Engineer-in-charge complete in all respects with face plates etcon the existing modular plate & switch box including connectionsas required 6 pin 15/16 amps socket outlet & switch for raw power 93 Supplying and fixing following modular switch/ sockets of legrand myrius/ schneider opale/ panasonic vision range or equivalent brand as approved by the Engineer-in-charge complete in all respects with face plates etcon the existing modular plate & switch box including connectionsas required 6 amps switch 94 Supplying and fixing following modular switch/ sockets of legrand myrius/ schneider opale/ panasonic vision range or equivalent brand as approved by the Engineer-in-charge complete in all respects with face plates etcon the existing modular plate & switch box including connectionsas required 3 pin 6A 2M Socket without shutter 95 Providing, fixing and installing of 18-20W surface Batten LED lighter, 6500K colour temperature, maximum system wattage of 20W , useful life of 50000 Hrs (Complete LM 80 test report for LED should be submitted) , isolated type, multistage Constant Current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with minimum 2KV surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less that 10% should be integral to the luminaire complete with all accessories required with lamps.Wipro , Tisva, Philips, Trilux or equivalent brand as directed by Engineer-in-Charge. The rate quoted is for inclusive of wiring of 2x1.5 sqmm, modular switch, modular plate, modular box etc all complete fittings for switching on and off of the fixture. Each fixtures to be controlled by 1 no. 5 amp. switch 96 Supply , installation, testing and commissionning of Ceilng fan 1200 mm sweep of 5 star BEE rated heavy dutyincluding hanging rod of required length, fixing of fan clamp to ceiling using fasteners making good the damage, any connection, as approved colour etc as required.The rate quoted is inclusive of wiring of 2x1.5 sqmm, modular switch, 2 module step type electronic fan regulator, modular plate, modular box etc all complete fittings for switching on and off of the fixture. Each fixtures to be controlled by 1 no. 5 amp. Switch 97 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 98 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 99 Supplying and fixing following way TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly wired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator).Hager/ Legrend/ Panasonic /Schenider or any equivalent make as approved by the Engineer-in-charge 4 way (4 + 12),Double Door 100 Supplying and fixing following way TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly wired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator).Hager/ Legrend/ Panasonic /Schenider or any equivalent make as approved by the Engineer-in-charge 6 way (4 + 18),Double Door 101 Supplying and fixing following rating, four pole, 415 volts, RCCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 amps 102 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.. Hager, Legrend & Schenider Double Pole 103 Supplying and fixing of conduit box for receiving incoming/outgoing wires for existing TPN/SPN distribution boardfacricated of 1.2 mm thick steel sheet for 415 volts on surface/ recess completeetc. as required 104 P/F 25mm x 5 mm GI earth strip in surface / recess : Providing and fixing 25mm X 5mm GI strip on surface or in recess for connections etc. as required. 105 P/F 25mm x 5 mm Copperstrip in surface / recess : Providing and fixing 25mm X 5mm copper strip on surface or in recess for connections etc. as required. 106 Earthing with copper earth plate 600mm X 600mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and wetering pipe of 2.7 metre long etc with charcol/coke and salt as required. 107 Providing and fixing 6 SWG dia. GI wire on surface or in recessed for loop earth as required. 108 Supply of following sizes of XLPE insulated PVC sheathed, copper conductor armoured power cable of 1.1 KV grade conforming to IS 7098 amended upto date.make as approved by the Engineer-in-charge 4 C x 6 sq.mm 109 Supply of following sizes of XLPE insulated PVC sheathed, copper conductor armoured power cable of 1.1 KV grade conforming to IS 7098 amended upto date.make as approved by the Engineer-in-charge 4 C x 10 sq.mm 110 Supply of following sizes of XLPE insulated PVC sheathed, copper conductor armoured power cable of 1.1 KV grade conforming to IS 7098 amended upto date.make as approved by the Engineer-in-charge 3.5 C x 35 sq.mm 111 Supplying and making end termination with brass compression gland and copperlugs for following size of PVC insulated PVC sheathed/XLPE copper conducter cable of 1.1 kV grade as required 4 C x 6 sq.mm 112 Supplying and making end termination with brass compression gland and copperlugs for following size of PVC insulated PVC sheathed/XLPE copper conducter cable of 1.1 kV grade as required 4 C x 10 sq.mm 113 Supplying and making end termination with brass compression gland and copperlugs for following size of PVC insulated PVC sheathed/XLPE copper conducter cable of 1.1 kV grade as required 3.5 C x 35 sq.mm 114 Providing detailed Architectural Drawings and Structural Design/Drawings duly vetted by reputed Govt. Institution i.e IIT/NIT/GCET/DIQC or equivalent including Soil bearing tests 115 Carriage of material by Mech.Transport from source to site of work a)Sand for 7 Kms lead 116 b) Bajree for 7 Kms lead 117 c) Bricksfor 25 Kms lead
|