Supply, Installation, Testing & Commissioning, Training, Operation& Maintenance Of Scada Based Automatic Operation Of Shahnehar Barrage And Its Canal System Supply, Installation, Testing And Commissioning, Training, Operation And Maintenance Of Scada Based Automatic Operation Of Shahnehar Barrage And Its Canal System , Part -A Supply , Supply Of Shaft Encoder Based Rotary Position Sensor With Digital Display, Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Ofgates, Including Cabling And Integration With Plc / Rtu / Datalogger As Per Technical Specifications. , Supply, Installation, Testing And Commissioning Of Side Looking Acoustic Doppler Based Velocity Meter ( Advm ) For Direct Downstream Discharge Measurement In Head / Cross Regulators Ofcanal System With Bed Width 20-120M As Per The Site Requirement, Including Integration With Plc / Rtu / Datalogger Including, Retractable Mounting Frame, Cabling, Complete As Per Technical Specifications. , Supply Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. Suitable Power Supply To Power Up Plc / Rtu Panel, Including Necessary Surge Protection With 7 Inches Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Of 3 Phase Vfd Starter Panel For Each Motor Of Dam & Head Regulator Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Bullet Camera Fixed Type ) -Ip Digital Night Vision ( I.R ) Out Door Weather Resistant, 2 Mega Pixel 2 Or4 With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) 3Mp Auto Iris Lens In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Barrage Complete As Per Technical Specifications. , Supply Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling Required For Barrage & Cross Regulator Monitoring. As Per Technical Specifications. , Supply Of Automated Water Level Transmitter Non-Contact Ultrasonic Type Having 10 M Range For Measuring Upstream Level / Downstreamdischarge In Canalincluding All Necessary Cabling With Suitable Conduits And Electrical Fittings And Mast Completeas Per Technical Specification. , Supply Of Automatic Water Level Recorder ( Non-Contact Radar Type ) For Rivers / Canals / Reservoirs Having 35M Range With All Necessary Cabling & Mounting Accessoriesas Per Technical Specifications. , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply ( Smps ) , 12” Display & Interconnection With Related Remote Plc / Rtu’S, Complete As Per Technical Specification. , Supply, Engineering And Development Of Customized Scada Software For Complete System For Barrage& Head Regulator Automation With Life Time Licensed Version As Per Technical Specifications. , Supply Of Master Gradeserver Which Includes Server With Work Station Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Highercompatible To Scada System Complete Forbarrage / Canal System, As Per Technical Specifications. , Supply Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd. Along With Dedicated Server With Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Supply Of Industrial Grade Computer Node As Workstation Along With Monitor, And Necessary Accessories, 42 Inch Led Display , 4G / 3Gdongles / Broadband, Installed With Client Scada Software Including 1 Kva Ups For Power Back Up And A4 Size Colour Printer As Per Technical Specifications At Division Monitoring Station With Necessary Accessories , Supply Of Laptops & 4G Internet Dongles Along With Licensed Version Of Client Scada Software For Remote Viewing & Monitoring Of Barrageautomation As Per Technical Specifications. , Supply Of It Hardware Which Includes Required Static Ip, Router, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications. , Supply Of 110” Smart Led Display System For Monitoring Of Canal Scada System At Canal Scada Control Room, As Per Technical Specifications. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up To Canal Scada Control Room Equipments As Per The Technical Specifications. , Supply Of Diesel Generator Set 10 Kva With 04 Earth Pits For Earthing At Canal Scada Control Room. , Supply Of Automatic Weather Station ( Aws ) With ( I ) Supply Of Air Temperature And Relative Humidity Sensor, Complete With Accessories As Per Specification. ( Ii ) Supply Of Wind Speed And Wind Direction Sensor Complete With Accessories As Per Specification. ( Iii ) Supply Of Solar Radiation Sensor Complete With Accessories As Per Specification. ( Iv ) Supply Of Barometric Pressure Sensor Complete With Accessories As Per Specification. ( V ) Automatic Rain Gauge. , Supply Of Data Logger 8 Analogue Channels Type With Gsm & Gprs Based Telemetry Including Antenna And All Necessary Equipment For Data Transmission As Per Technical Specifications , Supply Of Solar Panel, Charge Regulator, Batteries, Lightening Arrestor And Earth System In Nema4x Enclosure With All Connectors And Cables Including Integration Of The System With Earth Receiving Stations As Per Technical Specifications. , Part B- Installation , Installation, Testing And Commissioning Of Shaft Encoder Based Rotary Position Sensor With Digital Display, Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Gates, Including Cabling, And Integration With Plc / Rtu / Data Logger As Per Technical Specifications. , Installation, Testing And Commissioning Of Remote Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including Necessary Surge Protection With 7” Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Installation, Testing & Commissioning Of 3 Phase Vfd Starter Panel For Each Motor Of Dam Gates & Head Regulator Gates Which Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Installation, Testing And Commissioning & Integration With Nvr Located At Barrage Control Room Of Bullet Camera ( Fixed Type ) Ip Digital Night Vision ( I.R ) Out Door Weather Resistant, 2 Mega Pixel 2 Or4 With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array / 72 Led Colour Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) 3Mp Auto Iris Lens In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Shah Nehar Barrage Completeas Per Technical Specifications. , Installation, Testing & Commissioning & Integration With Nvr Located At Barrage Control Room Of Pan Tilt Zoom Camera, 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Camera In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling & Conducting Required For Barrage Monitoring , Installation, Testing & Commissioning Of Automated Water Level Transmitter Non-Contact Ultrasonic Type Having 10 M Range For Measuring Upstream Level / Downstreamdischarge In Canalincluding All Necessary Cabling With Suitable Conduits And Electrical Fittings And Mast Completeas Per Technical Specification. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measuring Upstream Level & Downstream Discharge Of Barrage. Including All Necessary Cabling, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation Testing And Commissioning Of Data Logger 8 Analogue Channels Type With Gsm & Gprs Based Telemetry Including Antenna And All Necessary Equipment For Data Transmission As Per Technical Specifications. , Installation Testing And Commissioning Of Solar Panel, Charge Regulator, Batteries, Lightening Arrestor And Earth System In Nema4x Enclosure With All Connectors And Cables Including Integration Of The System With Earth Receiving Stations As Per Technical Specifications. , Installation Testing And Commissioning Of Automatic Weather Station ( Aws ) With ( I ) Installation Testing And Commissioning Of Air Temperature And Relative Humidity Sensor, Complete With Accessories As Per Specification. ( Ii ) Installation Testing And Commissioning Of Wind Speed And Wind Direction Sensor Complete With Accessories As Per Specification. ( Iii ) Installation Testing And Commissioning Of Solar Radiation Sensor Complete With Accessories As Per Specification. ( Iv ) Installation Testing And Commissioning Of Barometric Pressure Sensor Complete With Accessories As Per Specification. ( V ) Automatic Rain Gauge , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply ( Smps ) , 12” Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc / Rtu’S, As Per Technical Specification. , Engineering, Testing & Commissioning Of Customized Scada Software For Complete Barrage And Head Regulator With Life Time Licensed Version As Per Technical Specifications , Installation, Testing And Commissioning Of Master Server Which Includes Server With Work Station Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete For Canal System, As Per Technical Specifications. , Installation, Testing & Commissioning Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd Along With Dedicated Server With Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Installation Testing & Commissioning Of Industrial Grade Computer Node As Workstation Along With Monitor, And Necessary Accessories, 42 Inch Led Display , 4G / 3G Dongles / Broadband, Installed With Client Scada Software Including 1 Kva Ups For Power Back Up And A4 Size Colour Printer As Per Technical Specifications At Division Monitoring Station With Necessary Accessories , Installation, Testing & Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Toscada Control Room Equipment As Per The Technical Specifications. , Installation, Testing & Commissioning Of It Hardware Which Includes Required Static Ip, Router, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Installation, Testing And Commissioning Of Diesel Generator Set 10 Kva With 04 Earth Pits For Earthing Atcanal Scada Control Room. , Installation, Testing And Commissioning Of 110” Smart Led Display System For Monitoring Of Canal System At Scada Control Room, As Per Technical Specifications. , Charges Of High-Speed Synchronous Internet Connection ( Min. 8 Mbps Upload And Download Speed ) And Static Ip For Barrage & Canal System For Five Years. , Charges For High Speed 4G Internet Dongle For Laptop With Client Scada Software For Remote Viewing &Monitoring Of System And 1Division Monitoring Stations For Five Years , Supply & Installation Ofair Conditioning System With Requisite Furniture , Renovation & Furnishing Of Existing Master Control Room For Establishment Of Scada Control Room Long With Necessary Electrical Fittingsas Per Technical Specification. , Five Years Operation & Maintenance And Comprehensive Warranty For Scada Based Canal Monitoring & Controlling Systemwith Telemetry Also Including O&M Of Automatic Weather System Along With All Accessories, Installed At Designated Locations Within Canal System After Final Acceptance Of The Scada Systems. This Includes Replacement Of All Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gsm & Gprs ( Sim & Internet Charges ) Telemetry For Data Transmission Shall Be Borne By Bidder. Minimum One Service Engineer Shall Be Placed At Canal Scada Control Room For Operation Of Canal Monitoring & Controlling System With Telemetry For Entire Warranty Period Of 5 Years. , Installation Of Chain-Link Fencing Of ( 10M*10M ) *2M Along With Lockable Gates For External Protection Of Sensors And Dcp For Aws As Per Technical Specification. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Start Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Plc / Rtu / Datalogger And Scada Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies As Per Technical Specification.
|