Development Of Distribution Infrastructure At Agra-1 Zone ( Electricity Distribution Circlesedc Fatehabad Edc Mainpuri, Edc Firozabad , Eudc Firozabad ) , District Agra, Mainpuri & Firozabadofuttar Pradeshstate Under The Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Supply Of Items 2 8.5 Mtr.Long , 180Kg . Pcc Poles As Per Approved Drawing And Technical Specification 3 9 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-33 ) 4 11 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-55 ) 5 13 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-72 ) 6 Stone Pad ( 300X300x75mm ) 7 1 Core ( Al. ) 120Mm2 Lt Armoured Xlpe Cable 8 1 Core ( Al. ) 95Mm2 Lt Armoured Xlpe Cable 9 1 Core ( Al. ) 50Mm2 Lt Armoured Xlpe Cable 10 1 Core ( Al. ) 25Mm2 Lt Armoured Xlpe Cable 11 11 Kvxlpe Cable 3X185 Sq. Mm. ( Armoured ) 12 1X25 Mm2 Pvc Insulated Al. Lt Cable For Energising The Distribution Boxes. 13 1X25 Mm2 Armoured Xlpe Insulated Al. Lt Cable For Energising The Distribution Boxes. 14 Armoured Service Cable 2Cx4 Sqmm For Single Phase Consumer 15 Armoured Service Cable 2Cx6 Sqmm For Single Phase Consumer 16 Armoured Service Cable 4Cx10 Sqmm For Three Phase Consumer 17 Armoured Service Cable 4Cx16 Sqmm For Three Phase Consumer 18 Lt Abc 3X120+1X95+1X16 Sq.Mm. ( Bare Massenger Wire ) 19 Lt Abc 3X50+1X35+1X16 Sq.Mm. ( Bare Massenger Wire ) 20 Lt Abc 3X95+1X70+1X16 Sq.Mm. ( Bare Massenger Wire ) 21 Lt Pvc Cable 3.5X150 Sq Mm 22 Lt Pvc Cable 3.5X70 Sq Mm 23 Lt Pvc Cable 4X16 Sq Mm 24 L.T. Pvc Cable 10 Sq. Mm Single Core 25 Lt Pvc Cable 3.5X400 Sq Mm 26 Acsr Rabbit Conductor 27 Aluminium Binding Wire - 6 Swg 28 Jointing Sleave 29 Mid Span Joint 120Mm2 30 Acsr Rabbit Conductor -Jumpering Works 31 Acsr Weasel Conductor-Jumpering Works 32 11 Kv Danger Board With Clamp And Nuts & Bolts 33 11 Kv Number Plate With Clamp And Nuts & Bolts 34 11Kv Fuse Set ( Drop Out ) With Clamps 35 11Kv Tpmo With Fixing Clamps 36 10 Kva, 11Kv / 250 V, 1 Ph Transformer As Bee Standard ( Self Protected ) . 37 16 Kva, 11Kv / 250 V, 1 Ph Transformer As Bee Standard ( Self Protected ) . 38 25 Kva , 11 / 0.433 Kv T / F ( Bee Standard 3 Star Rating Self Protected Aluminium Wound Type ) 39 63 Kva , 11 / 0.433 Kv T / F ( Bee Standard 3 Star Rating Self Protected Aluminium Wound Type ) 40 100 Kva , 11 / 0.433 Kv T / F ( Bee Standard 3 Star Rating Self Protected Aluminium Wound Type ) 41 Lt Distribution Box Withmccb For Protection Of 10 Kva T / F And Bus Bar Foroutgoing Consumer Connections And Suitable To House Energy Meter ( Without Energy Meter ) ( Deep Drawn Type ) As Per Ts. 42 Lt Distribution Box Withmccb For Protection Of 16 Kva T / F And Bus Bar Foroutgoing Consumer Connections And Suitable To House Energy Meter ( Without Energy Meter ) ( Deep Drawn Type ) As Per Ts. 43 Lt Incoming Panel With Ami Metering ( Smart Meter Compitable With System ) Equipment & Fixing Arrangement ( As Per Ts ) . ( Deep Drawn Type ) For 25Kva 44 Lt Incoming Panel With Ami Metering ( Smart Meter Compitable With System ) Equipment & Fixing Arrangement ( As Per Ts ) . ( Deep Drawn Type ) For 63 Kva 45 Lt Incoming Panel With Ami Metering ( Smart Meter Compitable With System ) Equipment & Fixing Arrangement ( As Per Ts ) . ( Deep Drawn Type ) For 100Kva 46 Lt Incoming Panel With Ami Metering ( Smart Meter Compitable With System ) Equipment & Fixing Arrangement ( As Per Ts ) . ( Deep Drawn Type ) For 250Kva 47 4 Core Lt Mcb With Box 48 Copper L-Piece 50X225x10mm 49 Copper L-Piece 50X225x12mm 50 Al Leg Long Barrel Off Size 51 9 Kv La , 5 Ka ( Distribution Class ) 52 9 Kv La , 10 Ka ( Station Class ) 53 Earthing Coil Connected With Nutbolt Using Charchol And Salt 54 Gi Flat 50X6 For Earthing 55 Gi Flat 25X3 For Earthing 56 Earthing Arrangement Ofchemical Pipe Size Of 80Mm , 3000 Mm.Long And 6 Swg Earthing Wire Etc. 57 Gi Pipe 6" Diameter With Clamps 58 G.I. Barbed Wire 59 G.I. Wire No. 16 Swg For Binding 60 G.I. Wire 6 Swg 61 G.I. Wire 8 Swg 62 33 Kv G.I. Pin ( 10 Kn ) With Nuts & Washers 63 11 Kv Disc Fitting B & S Type ( 45 Kn ) 64 11 Kv Disc. Insulators B&S Type 45 Kn ( Polymer Type ) 65 11 Kv Pin Insulator Polymer Type As Per Ts 66 33 Kv Pin Insulator 67 Lt Shackle Insulator 68 Insulating Piercing Connector ( 50-150 Sq.Mm ) 69 Insulating Piercing Connector ( 16-150 Sq.Mm ) 70 Dead End Clamp ( Insulated ) 71 End Cap For Ab Cable 72 Suspension Clamps ( Insulated ) 73 Pole Clamps With With I-Hook & Nut & Bolts For Laying Abc 74 D-Straps 75 Insulation Mastic Tape ( 2Inc X 10 Feet ) . 76 Single Phase Distribution Box With Clamps ( Deep Drawn Type ) - 1 Incoming And 8 Outgoing 77 Three Phase Distribution Box With Clamps ( Deep Drawn Type ) 1 Incoming And 4 Outgoing 78 Aluminium Paint 79 Red Oxide Paint 80 Smart Tvm Meter Compatible With System ( Ami ) Complete Set 81 Hdpe Pipe, Pn-4 Pe-80 ( 160 Mm Dia. ) With Clamp, Etc 82 Crimping Type Heavy Duty Aluminium Lugs Suitable For Connection Pvc Cables 83 Armour Rod With Ferrules For Acsr Rabbit / Weasel Helical Performed 84 Cable Route Marker 85 Pg Clamps 16 Sq Mm .- 50 Sq Mm ( For Line To Line Jumpering Of Massenger Wire & Energizing Db Neutral ) 86 Pg Clamp For Rabbit 87 Gi Stay Wire 7 / 10 Swg 88 Gi Stay Wire 7 / 8 Swg 89 Ht Guy Insulator 90 Lt Guy Insulator 91 33 Kv Stay Complete ( Gi Stay Rod 20X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 92 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 93 Turn Buckle 94 Ht Stay Clamp As Per Approved Drawing-33 Kv 95 Ht Stay Clamp As Per Approved Drawing-11 Kv 96 Lt Stay Clamp As Per Approved Drawing 97 11 Kv Cross Arm Holding Clamps With Bolts & Nuts 98 11 Kv Steel X-Arm V Type ( Gi Channel 65X 65 X 6 Mm ) 99 33 Kv Cross Arm Holding Clamps With Bolts & Nuts 100 33 Kv Steel X-Arm V Type ( Gi Channel 100 X 50 X 6 Mm ) 101 Angle For Vertical Arml50x50x6 ( Type -A ) -900Mm 102 Angle For Vertical Arml50x50x6 ( Type -B ) - 900Mm 103 Top Clamp For Vertical Arm L 50X6 ( Type -A ) - 435 Mm 104 Top Clamp For Vertical Arm L 50X6 ( Type -B ) - 435 Mm 105 Bottom Clamp For Vertical Arm L 50X6 ( Type -A ) - 507 Mm 106 Bottom Clamp For Vertical Arm L 50X6 ( Type -B ) - 507 Mm 107 Clamp For Top Channel With Nut Bolt 108 Clamps For Lt T-Off With Bolts & Nuts 109 E- Bracket For 11 Kv Line 110 Eye Bolt 111 F- Bracket For 11 Kv Line 112 F- Bracket For 33 Kv Line 113 Guarding Angle 65X55x6 Mm, 1.6 Mtr. With Clamp 114 Holding Clamps For Top Channel, Gi Channel & Gi Angle With Bolts & Nuts 115 M.S. Top Channel 100X50x6 Mm., 2240 Mmlong 116 Gi Angle Iron 65X65x6mm, 2700 Mm Long Bracing With 4 Clamps 117 Gi Channel 100X50x6 Mm 2028 Mm Long ( For Fuse Set ) 118 M.S. Top Channel 125X65x6 Mm., 2240 Mmlong 119 Tee-Off Channel 100X50x1300 Mm With Clamp, Nut & Bolt 120 Clamps For Dist. Box ( 40X6 Mm ) 121 Clamps For T / F ( 75X8 Mm Gi Flat ) . 122 Gi. Guarding Angle 75X75x6 Mm 3010 Mm Long With Clamp 123 Height Raising Channel 100X50, 2240 Mm Long 124 Back Clamp For Height Raising Channel Holding Clamps With Bolts & Nuts 125 Gi Channel 100X50x6 Mm. 1300 Mm Long 126 Gi Channel Clamp With Nuts & Bolts 127 Gi Angle Iron 50X50x6 Mm Bracing With 4 Clamps 128 Gi Channel 125X65 Mm 129 Giangle 75X75x6x2028 Mm With Clamp &Bolt And Nut ( T / F Base ) 130 Gi Channel 75X75x6 Mm &Bolt And Nut ( T / F Base Support ) 131 11 Kv, 1250 A Outgoing Vcb Indoor Type With Ctr 200 / 100 / 5 - 5A 350 Mva ( Compatible With Existing Vcb At 33 / 11 Kv Substation ) 132 Heat Shrinkable Jointing Kit Outdoor For 11 Kv 3X185 Sq. Mm Xlpe Cable 133 Cable Jointing Kit Straight Through ( 3X185 ) 134 Extra Prefabricated Items Like Clamp , Channel, Angle With Nut Bolt 135 Erection Part 136 Conversion Of Existing Service Cable To New Armoured Service Cable With All Required Accessories Like J-Pipe , Shaddle , Conduit Pipe , Clamp , Gi Wire , Reel Insulator , Earthing Bolt And Lugs Etc. ( Complete Work In All Respect ) And Removing And Shifting Of Existing Material To Client Store 137 Armoured Service Cable 2Cx4 Sqmm For Single Phase Consumer 138 Armoured Service Cable 2Cx6 Sqmm For Single Phase Consumer 139 Armoured Service Cable 4Cx10 Sqmm For Three Phase Consumer 140 Armoured Service Cable 4Cx16 Sqmm For Three Phase Consumer 141 Erection, Testingand Commissioning Of Replacement Oflt Bare Conductor With Ab Cables ( Complete Work In All Respect ) 142 8.5 Mtr.Long , 180Kg . Pcc Poles As Per Approved Drawing And Technical Specification 143 9 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-33 ) 144 Stone Pad ( 300X300x75mm ) 145 Lt Abc 3X120+1X95+1X16 Sq.Mm. ( Bare Massenger Wire ) 146 Lt Abc 3X95+1X70+1X16 Sq.Mm. ( Bare Massenger Wire ) 147 Lt Abc 3X50+1X35+1X16 Sq.Mm. ( Bare Massenger Wire ) 148 Pole Clamps With With I-Hook & Nut & Bolts For Laying Abc 149 Dead End Clamp ( Insulated ) 150 Suspension Clamps ( Insulated ) 151 Insulating Piercing Connector ( 16-150 Sq.Mm ) 152 Pg Clamps 16 Sq Mm .- 50 Sq Mm ( For Line To Line Jumpering Of Massenger Wire & Energizing Db Neutral ) 153 1X25 Mm2 Pvc Insulated Al. Lt Cable For Energising The Distribution Boxes. 154 Single Phase Distribution Box With Clamps ( Deep Drawn Type ) - 1 Incoming And 8 Outgoing 155 Three Phase Distribution Box With Clamps ( Deep Drawn Type ) 1 Incoming And 4 Outgoing 156 Earthing Coil Connected With Nutbolt Using Charchol And Salt 157 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 158 Lt Guy Insulator 159 Gi Stay Wire 7 / 10 Swg 160 Lt Stay Clamp As Per Approved Drawing 161 Removing And Shifting Of Existing Material To Client Store 162 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.268 Cmt ( 8.5 Meter - Pcc Pole ) As Per Approved Drawing 163 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.39 Cmt ( 9 Meter - Stp ) As Per Approved Drawing 164 Erection, Testingand Commissioning Of Replacement Ofab Cable ( Damage ) With Ab Cables ( Complete Work In All Respect ) 165 8.5 Mtr.Long , 180Kg . Pcc Poles As Per Approved Drawing And Technical Specification 166 9 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-33 ) 167 Stone Pad ( 300X300x75mm ) 168 Lt Abc 3X120+1X95+1X16 Sq.Mm. ( Bare Massenger Wire ) 169 Lt Abc 3X95+1X70+1X16 Sq.Mm. ( Bare Massenger Wire ) 170 Pole Clamps With With I-Hook & Nut & Bolts For Laying Abc 171 Dead End Clamp ( Insulated ) 172 Suspension Clamps ( Insulated ) 173 Insulating Piercing Connector ( 16-150 Sq.Mm ) 174 Pg Clamps 16 Sq Mm .- 50 Sq Mm ( For Line To Line Jumpering Of Massenger Wire & Energizing Db Neutral ) 175 1X25 Mm2 Pvc Insulated Al. Lt Cable For Energising The Distribution Boxes. 176 Single Phase Distribution Box With Clamps ( Deep Drawn Type ) - 1 Incoming And 8 Outgoing 177 Three Phase Distribution Box With Clamps ( Deep Drawn Type ) 1 Incoming And 4 Outgoing 178 Earthing Coil Connected With Nutbolt Using Charchol And Salt 179 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 180 Lt Guy Insulator 181 Gi Stay Wire 7 / 10 Swg 182 Lt Stay Clamp As Per Approved Drawing 183 Removing And Shifting Of Existing Material To Client Store 184 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.268 Cmt ( 8.5 Meter - Pcc Pole ) As Per Approved Drawing 185 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.39 Cmt ( 9 Meter - Stp ) As Per Approved Drawing 186 Erection, Testingand Commissioning Of Replacement Of Lt Line With Xlpe Armoured Cables ( Complete Work In All Respect ) 187 8.5 Mtr.Long , 180Kg . Pcc Poles As Per Approved Drawing And Technical Specification 188 9 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-33 ) 189 Stone Pad ( 300X300x75mm ) 190 Angle For Vertical Arml50x50x6 ( Type -A ) -900Mm 191 Top Clamp For Vertical Arm L 50X6 ( Type -A ) - 435 Mm 192 Bottom Clamp For Vertical Arm L 50X6 ( Type -A ) - 507 Mm 193 Angle For Vertical Arml50x50x6 ( Type -B ) - 900Mm 194 Top Clamp For Vertical Arm L 50X6 ( Type -B ) - 435 Mm 195 Bottom Clamp For Vertical Arm L 50X6 ( Type -B ) - 507 Mm 196 Lt Shackle Insulator 197 D-Straps 198 1 Core ( Al. ) 120Mm2 Lt Armoured Xlpe Cable 199 1 Core ( Al. ) 95Mm2 Lt Armoured Xlpe Cable 200 1 Core ( Al. ) 50Mm2 Lt Armoured Xlpe Cable 201 1 Core ( Al. ) 25Mm2 Lt Armoured Xlpe Cable 202 Mid Span Joint 120Mm2 203 Insulating Piercing Connector ( 50-150 Sq.Mm ) 204 Insulation Mastic Tape ( 2Inc X 10 Feet ) . 205 Single Phase Distribution Box With Clamps ( Deep Drawn Type ) - 1 Incoming And 8 Outgoing 206 Three Phase Distribution Box With Clamps ( Deep Drawn Type ) 1 Incoming And 4 Outgoing 207 1X25 Mm2 Armoured Xlpe Insulated Al. Lt Cable For Energising The Distribution Boxes. 208 Earthing Coil Connected With Nutbolt Using Charchol And Salt 209 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 210 Lt Guy Insulator 211 Gi Stay Wire 7 / 10 Swg 212 Lt Stay Clamp As Per Approved Drawing 213 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.268 Cmt ( 8.5 Meter - Pcc Pole ) As Per Approved Drawing 214 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.39 Cmt ( 9 Meter - Stp ) As Per Approved Drawing 215 Removing And Shifting Of Existing Material To Client Store 216 Survey , Erection, Testingand Commissioning Of 11 Kv Line ( Feeder Spliting Due To Over Loading ) On 8.5 Mtr Pcc Pole-115.6 Ckm And 11 Mtr Stp Pole -151.4 Ckm ( Complete Work In All Respect ) 217 Route Survey And Pole Spotting For 11 Kv Line 218 8.5 Mtr.Long , 180Kg . Pcc Poles As Per Approved Drawing And Technical Specification 219 11 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-55 ) 220 Acsr Rabbit Conductor 221 Stone Pad ( 300X300x75mm ) 222 11 Kv Steel X-Arm V Type ( Gi Channel 65X 65 X 6 Mm ) 223 11 Kv Cross Arm Holding Clamps With Bolts & Nuts 224 F- Bracket For 11 Kv Line 225 M.S. Top Channel 100X50x6 Mm., 2240 Mmlong 226 Clamp For Top Channel With Nut Bolt 227 Gi Angle Iron 65X65x6mm, 2700 Mm Long Bracing With 4 Clamps 228 E- Bracket For 11 Kv Line 229 11 Kv Pin Insulator Polymer Type As Per Ts 230 11 Kv Disc. Insulators B&S Type 45 Kn ( Polymer Type ) 231 11 Kv Disc Fitting B & S Type ( 45 Kn ) 232 Pg Clamp For Rabbit 233 Aluminium Binding Wire - 6 Swg 234 Jointing Sleave 235 11 Kv Danger Board With Clamp And Nuts & Bolts 236 G.I. Barbed Wire 237 Aluminium Paint 238 Red Oxide Paint 239 Earthing Coil Connected With Nutbolt Using Charchol And Salt 240 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 241 Ht Guy Insulator 242 Gi Stay Wire 7 / 10 Swg 243 Ht Stay Clamp As Per Approved Drawing-11 Kv 244 11 Kv Number Plate With Clamp And Nuts & Bolts 245 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.268 Cmt ( 8.5 Meter - Pcc Pole ) As Per Approved Drawing 246 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.44 Cmt ( 11 Meter - Stp ) As Per Approved Drawing 247 Erection, Testingand Commissioning Of 11 Kv Vcb With Complete Assoceries As Apporoved Drawing And Tecchanical Specifiactions ( Complete Work In All Respect ) 248 11 Kv, 1250 A Outgoing Vcb Indoor Type With Ctr 200 / 100 / 5 - 5A 350 Mva ( Compatible With Existing Vcb At 33 / 11 Kv Substation ) 249 11 Kvxlpe Cable 3X185 Sq. Mm. ( Armoured ) 250 Smart Tvm Meter Compatible With System ( Ami ) Complete Set 251 Earthing Arrangement Ofchemical Pipe Size Of 80Mm , 3000 Mm.Long And 6 Swg Earthing Wire Etc. 252 Gi Flat 50X6 For Earthing 253 8.5 Mtr.Long , 180Kg . Pcc Poles As Per Approved Drawing And Technical Specification 254 Stone Pad ( 300X300x75mm ) 255 M.S. Top Channel 100X50x6 Mm., 2240 Mmlong 256 Clamp For Top Channel With Nut Bolt 257 Gi Angle Iron 65X65x6mm, 2700 Mm Long Bracing With 4 Clamps 258 11 Kv Disc. Insulators B&S Type 45 Kn ( Polymer Type ) 259 11 Kv Disc Fitting B & S Type ( 45 Kn ) 260 Pg Clamp For Rabbit 261 11 Kv Danger Board With Clamp And Nuts & Bolts 262 G.I. Barbed Wire 263 Earthing Coil Connected With Nutbolt Using Charchol And Salt 264 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 265 Ht Guy Insulator 266 Gi Stay Wire 7 / 10 Swg 267 Ht Stay Clamp As Per Approved Drawing-11 Kv 268 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.268 Cmt ( 8.5 Meter - Pcc Pole ) As Per Approved Drawing 269 Survey , Erection, Testingand Commissioning Of 11 Kv Line ( Feeder Sagrigation ) ( Complete Work In All Respect ) 270 Route Survey And Pole Spotting For 11 Kv Line 271 8.5 Mtr.Long , 180Kg . Pcc Poles As Per Approved Drawing And Technical Specification 272 Acsr Rabbit Conductor 273 Stone Pad ( 300X300x75mm ) 274 11 Kv Steel X-Arm V Type ( Gi Channel 65X 65 X 6 Mm ) 275 11 Kv Cross Arm Holding Clamps With Bolts & Nuts 276 F- Bracket For 11 Kv Line 277 M.S. Top Channel 100X50x6 Mm., 2240 Mmlong 278 Clamp For Top Channel With Nut Bolt 279 Gi Angle Iron 65X65x6mm, 2700 Mm Long Bracing With 4 Clamps 280 E- Bracket For 11 Kv Line 281 11 Kv Pin Insulator Polymer Type As Per Ts 282 11 Kv Disc. Insulators B&S Type 45 Kn ( Polymer Type ) 283 11 Kv Disc Fitting B & S Type ( 45 Kn ) 284 Pg Clamp For Rabbit 285 Aluminium Binding Wire - 6 Swg 286 Jointing Sleave 287 11 Kv Danger Board With Clamp And Nuts & Bolts 288 G.I. Barbed Wire 289 Earthing Coil Connected With Nutbolt Using Charchol And Salt 290 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 291 Ht Guy Insulator 292 Gi Stay Wire 7 / 10 Swg 293 Ht Stay Clamp As Per Approved Drawing-11 Kv 294 11 Kv Number Plate With Clamp And Nuts & Bolts 295 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.268 Cmt ( 8.5 Meter - Pcc Pole ) As Per Approved Drawing 296 Erection, Testingand Commissioning Of 11 Kv Vcb With Complete Assoceries As Apporoved Drawing And Tecchanical Specifiactions ( Feeder Segrigation ) ( Complete Work In All Respect ) 297 11 Kv, 1250 A Outgoing Vcb Indoor Type With Ctr 200 / 100 / 5 - 5A 350 Mva ( Compatible With Existing Vcb At 33 / 11 Kv Substation ) 298 11 Kvxlpe Cable 3X185 Sq. Mm. ( Armoured ) 299 Smart Tvm Meter Compatible With System ( Ami ) Complete Set 300 Earthing Arrangement Ofchemical Pipe Size Of 80Mm , 3000 Mm.Long And 6 Swg Earthing Wire Etc. 301 Gi Flat 50X6 For Earthing 302 8.5 Mtr.Long , 180Kg . Pcc Poles As Per Approved Drawing And Technical Specification 303 Stone Pad ( 300X300x75mm ) 304 M.S. Top Channel 100X50x6 Mm., 2240 Mmlong 305 Clamp For Top Channel With Nut Bolt 306 Gi Angle Iron 65X65x6mm, 2700 Mm Long Bracing With 4 Clamps 307 11 Kv Disc. Insulators B&S Type 45 Kn ( Polymer Type ) 308 11 Kv Disc Fitting B & S Type ( 45 Kn ) 309 Pg Clamp For Rabbit 310 11 Kv Danger Board With Clamp And Nuts & Bolts 311 G.I. Barbed Wire 312 Earthing Coil Connected With Nutbolt Using Charchol And Salt 313 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 314 Ht Guy Insulator 315 Gi Stay Wire 7 / 10 Swg 316 Ht Stay Clamp As Per Approved Drawing-11 Kv 317 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.268 Cmt ( 8.5 Meter - Pcc Pole ) As Per Approved Drawing 318 Erection, Testingand Commissioning Of 11 Kv Nh Crossing ( Complete Work In All Respect ) 319 11 Kvxlpe Cable 3X185 Sq. Mm. ( Armoured ) 320 Heat Shrinkable Jointing Kit Outdoor For 11 Kv 3X185 Sq. Mm Xlpe Cable 321 Hdpe Pipe, Pn-4 Pe-80 ( 160 Mm Dia. ) With Clamp, Etc 322 Gi Pipe 6" Diameter With Clamps 323 11 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-55 ) 324 Gi Angle Iron 50X50x6 Mm Bracing With 4 Clamps 325 M.S. Top Channel 100X50x6 Mm., 2240 Mmlong 326 Clamp For Top Channel With Nut Bolt 327 G.I. Barbed Wire 328 Stone Pad ( 300X300x75mm ) 329 11 Kv Pin Insulator Polymer Type As Per Ts 330 11 Kv Disc. Insulators B&S Type 45 Kn ( Polymer Type ) 331 11 Kv Disc Fitting B & S Type ( 45 Kn ) 332 Pg Clamp For Rabbit 333 E- Bracket For 11 Kv Line 334 11 Kv Danger Board With Clamp And Nuts & Bolts 335 Aluminium Paint 336 Red Oxide Paint 337 Earthing Coil Connected With Nutbolt Using Charchol And Salt 338 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 339 Ht Guy Insulator 340 Gi Stay Wire 7 / 10 Swg 341 Ht Stay Clamp As Per Approved Drawing-11 Kv 342 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.44 Cmt ( 11 Meter - Stp ) As Per Approved Drawing 343 Cable Laying Including Cost Of Material Eg. , Bricks, Sand, Clamps Etc. 344 Erection, Testingand Commissioning Of 11 Kv Railway Crossing ( Complete Work In All Respect ) 345 11 Kvxlpe Cable 3X185 Sq. Mm. ( Armoured ) 346 Heat Shrinkable Jointing Kit Outdoor For 11 Kv 3X185 Sq. Mm Xlpe Cable 347 Hdpe Pipe, Pn-4 Pe-80 ( 160 Mm Dia. ) With Clamp, Etc 348 Gi Pipe 6" Diameter With Clamps 349 11 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-55 ) 350 Gi Angle Iron 50X50x6 Mm Bracing With 4 Clamps 351 M.S. Top Channel 100X50x6 Mm., 2240 Mmlong 352 Clamp For Top Channel With Nut Bolt 353 G.I. Barbed Wire 354 Stone Pad ( 300X300x75mm ) 355 11 Kv Pin Insulator Polymer Type As Per Ts 356 11 Kv Disc. Insulators B&S Type 45 Kn ( Polymer Type ) 357 11 Kv Disc Fitting B & S Type ( 45 Kn ) 358 Pg Clamp For Rabbit 359 E- Bracket For 11 Kv Line 360 11 Kv Danger Board With Clamp And Nuts & Bolts 361 Aluminium Paint 362 Red Oxide Paint 363 Earthing Coil Connected With Nutbolt Using Charchol And Salt 364 9 Kv La , 10 Ka ( Station Class ) 365 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 366 Ht Guy Insulator 367 Gi Stay Wire 7 / 10 Swg 368 Ht Stay Clamp As Per Approved Drawing-11 Kv 369 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.44 Cmt ( 11 Meter - Stp ) As Per Approved Drawing 370 Cable Laying Including Cost Of Material Eg. , Bricks, Sand, Clamps Etc. 371 Erection, Testingand Commissioning Of 11 Kv Line Crossing By 33Kv Lines On Stp 13 Mtr With Cradle Guarding ( Complete Work In All Respect ) 372 13 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-72 ) 373 33 Kv Steel X-Arm V Type ( Gi Channel 100 X 50 X 6 Mm ) 374 33 Kv Cross Arm Holding Clamps With Bolts & Nuts 375 33 Kv Pin Insulator 376 33 Kv G.I. Pin ( 10 Kn ) With Nuts & Washers 377 Gi. Guarding Angle 75X75x6 Mm 3010 Mm Long With Clamp 378 F- Bracket For 33 Kv Line 379 Turn Buckle 380 G.I. Wire 6 Swg 381 G.I. Wire 8 Swg 382 G.I. Wire No. 16 Swg For Binding 383 Eye Bolt 384 Armour Rod With Ferrules For Acsr Rabbit / Weasel Helical Performed 385 Stone Pad ( 300X300x75mm ) 386 11 Kv Danger Board With Clamp And Nuts & Bolts 387 11 Kv Number Plate With Clamp And Nuts & Bolts 388 G.I. Barbed Wire 389 Red Oxide Paint 390 Aluminium Paint 391 Aluminium Binding Wire - 6 Swg 392 Earthing Coil Connected With Nutbolt Using Charchol And Salt 393 Earthing Arrangement Ofchemical Pipe Size Of 80Mm , 3000 Mm.Long And 6 Swg Earthing Wire Etc. 394 33 Kv Stay Complete ( Gi Stay Rod 20X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 395 Ht Guy Insulator 396 Gi Stay Wire 7 / 8 Swg 397 Ht Stay Clamp As Per Approved Drawing-33 Kv 398 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.64 Cmt ( 13 Meter - Stp ) As Per Approved Drawing 399 Erection, Testingand Commissioning Of Lt Line Crossing By 11 Kv Lines On Stp 11 Mtr With Cradle Guarding ( Complete Work In All Respect ) 400 11 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-55 ) 401 11 Kv Steel X-Arm V Type ( Gi Channel 65X 65 X 6 Mm ) 402 11 Kv Cross Arm Holding Clamps With Bolts & Nuts 403 11 Kv Pin Insulator Polymer Type As Per Ts 404 F- Bracket For 11 Kv Line 405 Guarding Angle 65X55x6 Mm, 1.6 Mtr. With Clamp 406 Turn Buckle 407 G.I. Wire 6 Swg 408 G.I. Wire 8 Swg 409 G.I. Wire No. 16 Swg For Binding 410 Eye Bolt 411 Armour Rod With Ferrules For Acsr Rabbit / Weasel Helical Performed 412 Stone Pad ( 300X300x75mm ) 413 11 Kv Danger Board With Clamp And Nuts & Bolts 414 11 Kv Number Plate With Clamp And Nuts & Bolts 415 G.I. Barbed Wire 416 Red Oxide Paint 417 Aluminium Paint 418 Aluminium Binding Wire - 6 Swg 419 Earthing Coil Connected With Nutbolt Using Charchol And Salt 420 Earthing Arrangement Ofchemical Pipe Size Of 80Mm , 3000 Mm.Long And 6 Swg Earthing Wire Etc. 421 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 422 Ht Guy Insulator 423 Gi Stay Wire 7 / 8 Swg 424 Ht Stay Clamp As Per Approved Drawing-11 Kv 425 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.44 Cmt ( 11 Meter - Stp ) As Per Approved Drawing 426 Erection, Testingand Commissioning Of Ug Cable 11 Kv Line ( Complete Work In All Respect ) 427 11 Kvxlpe Cable 3X185 Sq. Mm. ( Armoured ) 428 Heat Shrinkable Jointing Kit Outdoor For 11 Kv 3X185 Sq. Mm Xlpe Cable 429 Cable Jointing Kit Straight Through ( 3X185 ) 430 Gi Pipe 6" Diameter With Clamps 431 Cable Route Marker 432 Hdpe Pipe, Pn-4 Pe-80 ( 160 Mm Dia. ) With Clamp, Etc 433 11 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-55 ) 434 Gi Angle Iron 50X50x6 Mm Bracing With 4 Clamps 435 M.S. Top Channel 100X50x6 Mm., 2240 Mmlong 436 Clamp For Top Channel With Nut Bolt 437 G.I. Barbed Wire 438 Stone Pad ( 300X300x75mm ) 439 11 Kv Pin Insulator Polymer Type As Per Ts 440 11 Kv Disc. Insulators B&S Type 45 Kn ( Polymer Type ) 441 11 Kv Disc Fitting B & S Type ( 45 Kn ) 442 Pg Clamp For Rabbit 443 E- Bracket For 11 Kv Line 444 11 Kv Danger Board With Clamp And Nuts & Bolts 445 Aluminium Paint 446 Red Oxide Paint 447 Earthing Coil Connected With Nutbolt Using Charchol And Salt 448 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 449 Ht Guy Insulator 450 Gi Stay Wire 7 / 10 Swg 451 Ht Stay Clamp As Per Approved Drawing-11 Kv 452 Road Restoration Chages Forroad Crossing 453 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.44 Cmt ( 11 Meter - Stp ) As Per Approved Drawing 454 Erection, Testingand Commissioningof 11 / 0.433 Kv Three Phase Transformer Sub-Station -25 Kva , 63 Kva And 100 Kva ( Complete Work In All Respect ) 455 8.5 Mtr.Long , 180Kg . Pcc Poles As Per Approved Drawing And Technical Specification 456 Gi Channel 100X50x6 Mm 2028 Mm Long ( For Fuse Set ) 457 Stone Pad ( 300X300x75mm ) 458 Clamps For Lt T-Off With Bolts & Nuts 459 Holding Clamps For Top Channel, Gi Channel & Gi Angle With Bolts & Nuts 460 Giangle 75X75x6x2028 Mm With Clamp &Bolt And Nut ( T / F Base ) 461 M.S. Top Channel 125X65x6 Mm., 2240 Mmlong 462 11 Kv Disc. Insulators B&S Type 45 Kn ( Polymer Type ) 463 11 Kv Disc Fitting B & S Type ( 45 Kn ) 464 Tee-Off Channel 100X50x1300 Mm With Clamp, Nut & Bolt 465 11 Kv Pin Insulator Polymer Type As Per Ts 466 25 Kva , 11 / 0.433 Kv T / F ( Bee Standard 3 Star Rating Self Protected Aluminium Wound Type ) 467 63 Kva , 11 / 0.433 Kv T / F ( Bee Standard 3 Star Rating Self Protected Aluminium Wound Type ) 468 100 Kva , 11 / 0.433 Kv T / F ( Bee Standard 3 Star Rating Self Protected Aluminium Wound Type ) 469 11Kv Tpmo With Fixing Clamps 470 11Kv Fuse Set ( Drop Out ) With Clamps 471 9 Kv La , 5 Ka ( Distribution Class ) 472 Lt Incoming Panel With Ami Metering ( Smart Meter Compitable With System ) Equipment & Fixing Arrangement ( As Per Ts ) . ( Deep Drawn Type ) For 25Kva 473 Lt Incoming Panel With Ami Metering ( Smart Meter Compitable With System ) Equipment & Fixing Arrangement ( As Per Ts ) . ( Deep Drawn Type ) For 63 Kva 474 Lt Incoming Panel With Ami Metering ( Smart Meter Compitable With System ) Equipment & Fixing Arrangement ( As Per Ts ) . ( Deep Drawn Type ) For 100Kva 475 Lt Pvc Cable 4X16 Sq Mm 476 Lt Pvc Cable 3.5X70 Sq Mm 477 Lt Pvc Cable 3.5X150 Sq Mm 478 11 Kv Danger Board With Clamp And Nuts & Bolts 479 G.I. Barbed Wire 480 Acsr Rabbit Conductor- Jumpering Works 481 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 482 Ht Guy Insulator 483 Gi Stay Wire 7 / 10 Swg 484 Ht Stay Clamp As Per Approved Drawing-11 Kv 485 Earthing Arrangement Ofchemical Pipe Size Of 80Mm , 3000 Mm.Long And 6 Swg Earthing Wire Etc. 486 Gi Flat 25X3 For Earthing 487 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.268 Cmt ( 8.5 Meter - Pcc Pole ) As Per Approved Drawing 488 Erection, Testingand Commissioningof 11 / 0.433 Kv Three Phase Transformer Sub-Station -10 Kva And 16 Kva ( Complete Work In All Respect ) 489 10 Kva, 11Kv / 250 V, 1 Ph Transformer As Bee Standard ( Self Protected ) . 490 16 Kva, 11Kv / 250 V, 1 Ph Transformer As Bee Standard ( Self Protected ) . 491 Lt Distribution Box Withmccb For Protection Of 10 Kva T / F And Bus Bar Foroutgoing Consumer Connections And Suitable To House Energy Meter ( Without Energy Meter ) ( Deep Drawn Type ) As Per Ts. 492 Lt Distribution Box Withmccb For Protection Of 16 Kva T / F And Bus Bar Foroutgoing Consumer Connections And Suitable To House Energy Meter ( Without Energy Meter ) ( Deep Drawn Type ) As Per Ts. 493 Clamps For Dist. Box ( 40X6 Mm ) 494 Clamps For T / F ( 75X8 Mm Gi Flat ) . 495 Acsr Weasel Conductor-Jumpering Works 496 11 Kv Pin Insulator Polymer Type As Per Ts 497 Eye Bolt 498 L.T. Pvc Cable 10 Sq. Mm Single Core 499 Earthing Arrangement Ofchemical Pipe Size Of 80Mm , 3000 Mm.Long And 6 Swg Earthing Wire Etc. 500 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 501 Ht Guy Insulator 502 Gi Stay Wire 7 / 10 Swg 503 Ht Stay Clamp As Per Approved Drawing-11 Kv 504 Relocation , Testing And Commissioningof 250 Kva , 11 / 0.433 Kv Three Phase Transformer Sub-Station ( Complete Work In All Respect ) 505 11 Meter Long Stp As Per Approved Drawing And Technical Specification ( Sp-55 ) 506 Gi Channel 100X50x6 Mm 2028 Mm Long ( For Fuse Set ) 507 Stone Pad ( 300X300x75mm ) 508 Holding Clamps For Top Channel, Gi Channel & Gi Angle With Bolts & Nuts 509 M.S. Top Channel 125X65x6 Mm., 2240 Mmlong 510 Giangle 75X75x6x2028 Mm With Clamp &Bolt And Nut ( T / F Base ) 511 Gi Channel 75X75x6 Mm &Bolt And Nut ( T / F Base Support ) 512 11 Kv Disc. Insulators B&S Type 45 Kn ( Polymer Type ) 513 11 Kv Disc Fitting B & S Type ( 45 Kn ) 514 Tee-Off Channel 100X50x1300 Mm With Clamp, Nut & Bolt 515 Clamps For Lt T-Off With Bolts & Nuts 516 11 Kv Pin Insulator Polymer Type As Per Ts 517 11Kv Tpmo With Fixing Clamps 518 11Kv Fuse Set ( Drop Out ) With Clamps 519 Lt Incoming Panel With Ami Metering ( Smart Meter Compitable With System ) Equipment & Fixing Arrangement ( As Per Ts ) . ( Deep Drawn Type ) For 250Kva 520 Copper L-Piece 50X225x10mm 521 Copper L-Piece 50X225x12mm 522 Lt Pvc Cable 3.5X400 Sq Mm 523 Al Leg Long Barrel Off Size 524 4 Core Lt Mcb With Box 525 11 Kv Danger Board With Clamp And Nuts & Bolts 526 G.I. Barbed Wire 527 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 528 Ht Guy Insulator 529 Gi Stay Wire 7 / 10 Swg 530 Ht Stay Clamp As Per Approved Drawing-11 Kv 531 Earthing Arrangement Ofchemical Pipe Size Of 80Mm , 3000 Mm.Long And 6 Swg Earthing Wire Etc. 532 Gi Flat 50X6 For Earthing 533 Gi Channel 125X65 Mm 534 9 Kv La , 5 Ka ( Distribution Class ) 535 Crimping Type Heavy Duty Aluminium Lugs Suitable For Connection Pvc Cables 536 Pg Clamp For Rabbit 537 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.44 Cmt ( 11 Meter - Stp ) As Per Approved Drawing 538 Dt"S Plinth Foundation 539 Dismentaling Of Distribution Transformer Along With Accessories. Relocate The Dt Only At New Location , Testing , Comissioning And Charging And Other Shifting To Store. 540 Erection, Testingand Commissioning Of New Lt Line With Ab Cable ( Complete Work In All Respect ) 541 8.5 Mtr.Long , 180Kg . Pcc Poles As Per Approved Drawing And Technical Specification 542 Stone Pad ( 300X300x75mm ) 543 Lt Abc 3X50+1X35+1X16 Sq.Mm. ( Bare Massenger Wire ) 544 Lt Abc 3X95+1X70+1X16 Sq.Mm. ( Bare Massenger Wire ) 545 Pole Clamps With With I-Hook & Nut & Bolts For Laying Abc 546 Dead End Clamp ( Insulated ) 547 Suspension Clamps ( Insulated ) 548 Pg Clamps 16 Sq Mm .- 50 Sq Mm ( For Line To Line Jumpering Of Massenger Wire & Energizing Db Neutral ) 549 Insulating Piercing Connector ( 16-150 Sq.Mm ) 550 1X25 Mm2 Pvc Insulated Al. Lt Cable For Energising The Distribution Boxes. 551 Single Phase Distribution Box With Clamps ( Deep Drawn Type ) - 1 Incoming And 8 Outgoing 552 Three Phase Distribution Box With Clamps ( Deep Drawn Type ) 1 Incoming And 4 Outgoing 553 Earthing Coil Connected With Nutbolt Using Charchol And Salt 554 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 555 Lt Guy Insulator 556 Gi Stay Wire 7 / 10 Swg 557 Lt Stay Clamp As Per Approved Drawing 558 Concreting Works Of Poles Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 20 Mm Size Stone Aggregate Chips ( 1:2:4 ) -0.268 Cmt ( 8.5 Meter - Pcc Pole ) As Per Approved Drawing 559 Erection, Testingand Commissioning Of 11Kv Line Guarding ( Complete Work In All Respect ) 560 Guarding Angle 65X55x6 Mm, 1.6 Mtr. With Clamp 561 Height Raising Channel 100X50, 2240 Mm Long 562 Back Clamp For Height Raising Channel Holding Clamps With Bolts & Nuts 563 G.I. Wire 6 Swg 564 G.I. Wire 8 Swg 565 Turn Buckle 566 Eye Bolt 567 G.I. Wire No. 16 Swg For Binding 568 Earthing Coil Connected With Nutbolt Using Charchol And Salt 569 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 570 Ht Guy Insulator 571 Gi Stay Wire 7 / 10 Swg 572 Ht Stay Clamp As Per Approved Drawing-11 Kv 573 Erection, Testingand Commissioning Of Tee Of Channel ( Complete Work In All Respect ) 574 Gi Channel 100X50x6 Mm. 1300 Mm Long 575 Gi Channel Clamp With Nuts & Bolts 576 11 Kv Disc. Insulators B&S Type 45 Kn ( Polymer Type ) 577 11 Kv Disc Fitting B & S Type ( 45 Kn ) 578 11 Kv Pin Insulator Polymer Type As Per Ts 579 Pg Clamp For Rabbit 580 Stay Complete ( Gi Stay Rod 16X1800 Mm, Eye Bolt, Anchor Plate, Turn Buckle And Thimble ) Bolt, Nuts Bolt & Washers 581 Ht Guy Insulator 582 Gi Stay Wire 7 / 10 Swg 583 Ht Stay Clamp As Per Approved Drawing-11 Kv 584 Control Room Building Extention Work ( Complete Work In All Respect ) 585 Rcc Work Of Building With Internal Wiring Works For Extension Of Control Room Building ( 36 Sqmm ) ( Complete Works In All Respect ) As Per Approved Drawing And Specification 586 Water Pump, Toilet Works As Per Approved Drawing And Specification
|