Quotation Are Invited For Integrity Inspection, Remaining Life Analysis And Fitness For Service Assessment Integrity Inspection, Remaini 1032201586Rfx Description Integrity Inspection, Remaining Life Analysis And Fitness For Service Assessment For Dfo Storage Tank E And F At Dewa L Ii Station. Contact Ankan Kumar Tel: 04-814-0587/ 0556361082 1 Item-00001 Technical And General Specification Of Outsourcing Work At L-Ii Station, Jebel Ali Power Station. Name Of The Work: Integrity Ana Lysis, Fitness For Service Assessment And Next Inspection Required Date Of Dfo Storage Tank E And F At Dewa L Ii Station. Conduct In Ternal/External Inspection And Recommended, Ndt Analysis In Compliance To Api 653. On The Basis Of Findings In Nde, Fitness For Serv Ice Assessment Shall Be Carried Out And Recommendations For Repair (If Any) Shall Be Provided. Inspection And Analysis Shall Be Carr Ied Out By A Person Holding Valid Api 653 Inspector Certification To Do The Tasks. A Final Report With Details Of Inspection Carried Out, Result Analysis, Recommendations, Next Inspection Date And Ffs Certificate Shall Be Provided As A Part Of This Work. 1 Ea Qty-2 No Tank Size: 30.5 M Dia X 22.0 M High Type Of Tank: Self Supported Cone Roof Cylindrical Tank Capacity (Net): 14500 Cu. M Design Code : Api Std 650, 10Th Edition Design Pressure: Atm Scope Of Work And Tank Drawings Attached. Period Of Work: Dfo Tank-Enov-2022 Dfo Tank-F- March-2023 Scope Of Work: Integrity Analysis, Fitness For Service Assessment And Next Inspection Required Date Of Dfo Stor Age Tanks At Dewa L Ii Station. Conduct Internal/External Inspection And Recommended Ndt Analysis In Compliance To Api 653. On The B Asis Of Findings In Nde, Fitness For Service Assessment Shall Be Carried Out And Recommendations For Repair (If Any) Shall Be Provid Ed. Inspection And Analysis Shall Be Carried Out By A Person Holding Valid Api 653 Inspector Certification To Do The Task. A Final R Eport (Hard Copy & Cd) With Details Of Inspection Carried Out, Result Analysis, Recommendations, Next Inspection Date And Ffs Certif Icate Shall Be Provided As A Part Of This Work. Qty-2 Nos. Scope Of Work Include, But Not Limited To The Following. 1.#The Contrac Tor Shall Visit The Site And Make Himself Fully Familiar With The Work Scope, Plant Access, Facilities, Complexities, Safety Measure S Etc., Before He Submit His Bid. 2.#Contractor Should Have The Previous Experience With Similar Type Of Jobs In Dewa Or With Other Well-Known Company. 3.#To Get A Ptw, Contractor Has To Submit Risk Assessment And Method Statement Prior To Start The Work. 4.#Check Condition Suitable To Carry Out Work Conduct Site Survey And Safety Inspection To Assess The Working Environment. 5.#If Working En Vironment Is Safe Proceed The Following Steps. 6.#Mobilize The Api Authorized Inspector With Suitable Inspection Tools, Ppes And Con Sumables, Etc. On 3 Days# Notice Period. 7.#A Safety Meeting Will Be Held To Evaluate The Risk Involved In Methods To Be Used. Risk Assessment And Method Of Statement To Be Reviewed Prior To Start The Inspection. Tank Inservice Inspection: 1.#In-Service External Inspection To Be Carried By An Authorized Inspector. 2.#The External Condition Of The Tank Shall Be Monitored By Close Visual Inspe Ction From The Ground. 3.#Visual Inspection Of The Tank Exterior Surfaces, Stair, Roof, Area Of Wear, Shell Distortion, Corrosion, F Oundation & Sign Of Settlement. 4.#Check The Periphery Of The Tank Foundation For Any Signs Of Product Leakage All Around The Periph Ery Of The Tank, This May Be An Indication Of A Leak Near The Center Of The Tank Or A Number Of Leaks Spread Over The Bottom. 5.#Dew A In Service Inspection Check List To Be Filled Addition To The Standard In Service Inspection Report. 6.#Dewa In Service Inspection Check List To Be Reviewed And Inform Dewa If Any Alteration/Up Gradation Is Required In Service Inspection Check List Document As P Er Api Standard. Tank External Out Of Service Inspection: 1.#The External Inspection Must Be Conducted By An Authorized Inspector. 2.#A Complete Visual Inspection Shall Be Performed To Identify Any Surface Defect. 3.#The Main Purpose Of The External Inspection Is To Check The Foundation, Shell, Accessories And Roof. 4.#The Observations Shall Concentrate On Leakage From Under The Bottom, Shel L Settlement, Verticality, Shell Deformations (Flat Spots, Buckles Or Bulges), Corrosion Spots Etc. 5.#The Observations Should Inclu De The Condition Of Paint Work, Safety Of Stairs, Platforms And Handrails And Proper Functioning Of Service Equipment. 6.#Inspection And Monitoring All Leak Detection Systems, Cathodic Protection Monitoring Equipment Or Other Monitoring Or Warning Systems W Hich May Be In Place At The Facility. 7.#Verify Wall Thickness Then A Suitable Ultrasonic Thickness Measurement Technique Shall Be A Pplied. 8.#When There Is Concern That There May Be Cracking In Welds Or In Other Parts Of The Tank Then The Defects Shall Be Verifie D By Applying An Appropriate Non-Destructive Testing Technique, E.G. Radiography Or Ultrasonic Test, Dye Penetrant Or Magnetic Parti Cle Examination. 9.#Surface Corrosion, Weld Defects Or Coating To An Extent, Which Could Affect The Integrity Of The Tank Shall Be I Nspected By Appropriate Methods. 10.#The Tank Shell Shall Be Inspected For Signs Of Deformation (Flat Spot, Buckle Or Bulge), Leakag E Or Corrosion Of Bottom Edge And Shell Plates. 11.#Stiffening Rings To Prevent Buckling Due To Wind Loads And High Thermal Stresses At Low Ambient (Winter) Temperatures Should Also Be Checked. 12.#Before Stepping Onto The Roof Of A Cone-Roof Tank A Visual Check S Hall Be Made For External Corrosion Or Holes. Use Hammer To Check The Roof Before Entering. 13.#If There Are Indications That Corros Ion Has Penetrated The Roof, Access To The Roof Shall Be Prohibited. 14.#The Following Elements Shall Be Inspected But Not Limited T O By An Appropriate Method To Ensure That They Are In Good Condition: ##Structures Supporting And Reinforcing The Tank ##Means Of A Ttachment To Tank System ##Any Service Equipment Like Level Gauges, Earth Lug, Breathers, Heat Detectors, Stairs Etc. ##Drains, Tren Ches, Drain Collection Pit And Interceptor Etc. ##Firefighting Accessories And System 15.#It Shall Also Include The Connected Pipel Ines And Bellows For Puncture Or Cracks. 16.#The Proper Functioning Of External Equipment Such As Vents, Pressure/Vacuum Valves, Gau Ging Devices And Water-Draining Equipment Shall Be Established. 17.#Flexible Joints And Fixed Hoses As Part Of The Filling And/Or Di Scharging System Shall Be Visually Inspected. 18.#Bolted Flanges, Caps To Valves At Bottom Outlets Shall Be Checked For Worn Threads And Damaged Gaskets. 19.#All Service Equipment Including Any Permanently Attached Hoses Shall Be Inspected In The Mounted Position For Correct Functioning. 20.#In Addition To A General Inspection Of The Steelwork Particular Attention Shall Be Paid To: Supports To Tank Shell, Intermediate Platforms And Hand Railing, Concrete Pedestal Supports For Stairways, The Cracks In The Tank Concrete Foun Dation 21.#The Part Of The Foundation Which Projects Beyond The Base Of The Tank (The Shoulder) Shall Be Inspected To Verify That Th E Tank Bottom Sealing Is In Good Condition As It Is Possible That Minor, Even Settlement Of A Tank Will Form A Channel Around The Pe Riphery Of The Tank Bottom In Which Rainwater Will Collect And Cause Serious Corrosion Of The Bottom-To-Shell Connection. 22.#The Sl Ope Of The Shoulder Of The Tank Concrete Foundation Should Ensure Good Drainage Of Rain Water. 23.#Dewa External Out Of Service Insp Ection Check List To Be Filled Addition To The Standard External Out Of Service Inspection Report. 24.#Dewa External Out Of Service Inspection Check List To Be Reviewed And Inform Dewa If Any Alteration/Up Gradation Is Required In Service Inspection Check List Doc Ument As Per Api Standard. Tank Internal Out Of Service Inspection: 1.#The Internal Inspection Is Required Solely For The Purpose Of Determining The Condition And Integrity Of The Tank Bottom. 2.#The Authorized Inspector Who Is Responsible For Evaluation Of A Ta Nk Must Conduct A Visual Inspection And Assure The Quality. 3.#A Complete Visual Inspection Shall Be Performed To Identify Any Surfa Ce D 2 Item-00001 Integrity Analysis, Fitness For Service Assessment And Next Inspection Required Date Of Dfo Storage Tank F. 1 Ea Standard Terms & Conditions 1) Prices Should Be Ddp Delivery Duty Paid At Dewa Stores. 2) Quotation To Be Submitted Only In Local Currency U.A.E Dirhams 3) Dewa Standard Payment Terms Is 30 Days Credit From The Date Of Acceptance Of Material 4) No Dewa Staff Or His Or Her Relatives Up To Third Degree Should Have Ownership Or Partnership In Your Company, And Your Participation In Dewa Tenders / Rfqs Should Not Constitute A Conflict Or Perceived Conflict Of Interest. Tender Link : Https://Www.Dewa.Gov.Ae/Api/Rfxdownload/2332201014
|