Dental Equipments Dental Instruments And Equipments , 3 Point Articulator / Plane Articulator ( Mean Value Articulator ) , Acryliser Programmable Preheating Time & Temperature Programmable Curing Time & Temperature Analog Control Unit Capacity-6-8 Flask Digital Programming , Adson” Tooth Forceps 5” , Adsons Tooth Forceps 8” , Advance Digital Microscope With Imaging Software ( With Desktop + Printer + Ups + Mouse ) Optical System- Infinity Color Corrected Optical System Observation Tube:Seidentopf Digital Viewing Head, 3.2 Million Pixels High Resolution Camera System: Resolution Ratio 2048*1536 Pixels, Line By Line Scan Eyepiece: High Eye Point Wide Field Plan Eyepiece Pl10x / 20Mm, With ±5 Degrees Diopter Control, Ipd: 50-75Mm Objective:Plan Achromatic Objective 4X Plan Achromatic Objective 10X Plan Achromatic Objective 40X Spring Plan Achromatic Objective 100X S, Oil Nosepiece:Backward Quadruple Nosepiece Illumination- Main Supply 100V-240V, 3 Watt Led Lamp Or 6V / 20W Halogen With Intensity Control ( Fixed Center ) Focusing Adjustment:Coaxial Coarse And Fine Focusing Adjustment, With Limited And Tension Adjustment Coarse Adjustment Range: 25Mm, Fine Adjustment Precision:0.002Mm. Condenser: N.A.1.25 Condenser ( With Socket For Phase Contrast And Dark Field Sliders ) Stage:Coaxial Mechanical Stage 140X132mm Size And 76×50Mm Travel Range. Inbuilt Microscopic Scientific Digital Camera With Imaging Software Consisting Of: High Resolution Digital Camera With 1 / 2” Cmos Chip Usb 2.0 Pc Connection Real Time Live Image Resolution: 3 Mega Pixels Electronic Shutter Exposure Time: 1Ms-0.3S Working Temperature: -20°C ~ 70°C Image Analysis Software: Sportily Calibration Line Measurements For Distance, Length, Width, Perimeter, Angle, Three Point Radius. Area By Enclosed Line Controlled By Four Arrow Keys Available On The Keyboard Arrow With Zoomed Preview The Line Measurement Is Not Affected On Zoomed Images. Identification Of Objects In An Image, Count Them, Obtain Several Features Measurements. Objects Identification By User Or Automatically. User Defined Classification On Basis Of Size Or Intensity. Manual, Auto Bright And Auto Dark Methods To Identify Intensity Range Defined Object To Be Measured. Various Calculation & Measurements Available For Selected Particle Are; Dimensions, Area, Perimeter, Ferrite Length, Min / Max Radius, Thread Length, Thread Width, Fiber Length, Fiber Width. Roundness, Shape, Orientation, Elongation, Equal Circular Diameter, Equal Sphere Volume, Data Export Report Generating And Print Out Interactive File Format. , Advanced Research Microscope , Air Purifier , Airotor Cartridge Suitable For Nsk Airotor Hand Piece , Airotor Control Box With Inbuilt Micromotor , 3 Way Syringe & 02 Nos. Airotor Control With Trolly , Airotor Hand Piece ( Chuck ) , Airotor Hand Piece Noiseless Ultra Push Type – With Ceramaic Bearing Super Torque Head , Airotor Oiling Machine , Alcohol Torch With Adjustable Flame , Allis Forcep 5” , Allis Forcep 6” , Alloy Cutter Compact Alloy Cutter With High Speed Grinding And Dependable Trouble Free Operation With Vaccum Suction Safety Glass For Glare Elimination And Visual Protection 20000 Rpm , Amalgam Carrier , Amalgamator , Anesthesia Machine ( Boyle Apparatus ) 1. Ms & Aluminum Combined Structure With Polyurethane Coated Finish For Long Life. 2. Forged Body Regulators For Medical Oxygen & Nitrous Oxide For Maintenance Free Operation. 3. Two Numbers Each Forged Yokes With Ss Fittings For Medical Oxygen & Nitrous Oxide At The Sides. 4. Colour Coded Yoke Mounted High Pressure Gauges. 5. Two Tube Rotameter With Oxygen Ratio Controller With Unitized Rotameter. 6. Magill’S Breathing System One Number In Addition. 7. Bain’S Breathing System One Number In Addition 8. Safety Features : • Oxygen Failure Warning Device ( Ofwd ) • Nitrous Oxide Cut Off In The Absence Of Oxygen • Oxygen Ratio Controller 9. Large Diameter Castor Wheels With Individual Brakes At Front Castors 10. One Year Standard Warranty 11. Local Service Support With Hand-Phone Number Of Engineer 12. Should Be Manufactured In An Iso Certified Facility 13. Circle Absorber May Be Quoted As An Option 14. Cage-Mount Isoflurance Vaporizer May Be Quoted As An Option , Angled Model Saw , Anoxic Polisher Cum Reducer , Anterior Band Removing Plier , Apex Locator 5Th Generation Or Above , Artery Forcep Artery 6” , Artery Forceps Artery 5” , Articulator Model Jp30, Gnatus - Brazil Sem Adjustable Safe And Easy Operation Its Offers A Better Performance High And Precision Easy To Take Patients Impression And To Mount The Model. Appropriate For Diagnotics And Clinic Planning Ideal For Laboratory, Used In Many Produres Accessories Bite Fork For Teeth Bite Fork For Toothless Ruler / Face Bow Fork Support Mounting Table Incisal Table Metallic Moounting Plates. , Articulator Wide View Individually Adjustable, All The Joint Angles Can Be Continuously Set Without Having To Replace Any Elements, Centric Locking Catch, Seprable Upper & Lower Frame, Optimized Joint Mechanics With Continuously Adjustable Angles - Protrusion ( 0-60 Degree ) , Retrusion 35 Degree, Bennett ( 0-30 Degree ) , Side Shift 0- \ 1.5Mm, Protrusion Shift 0- 4Mmcompatible With Split Cast System With Earpiece Type Spring Facebowtransfer Complete Assembly, One Pair Metallic And Ten Pair Of Plastic Mounting Plates , Austins Retractor , Auto Clavabel Hand Piece , Stateof The Art Piexon Techonology , No Heat Generation In Hand Piece, Titanium Tip , Autoclave ( Vertical Loading ) Overall Size 18”X13”X15” Cm Capacity Of 25 Liters Inside Dimension : Dia 30.5 Cm. Depth 38.0 Cm. Cycle Time 16 Minat 127 C, 19 Psi Power Consumption 220V / 50Hz 2K. Watt Heater Provided At The Base Of The Body With 2 Drums Of Ss 11X5 Inch Body Is Made Of 7 Mm Thick Aluminum Sheet Imported Insulation Material Provided To Avoid And Heat Loss Total Cycle Time From Room Temperature Is Approximate 36 Minutes For First Cycle And Approximate 28 Minutes For Consequent Cycles Power Saving As Heater Automatically Off And On After Reaching The Required Temperature , Autoclave Front Loading B-Type Front Loading Fully Automatic Autoclave With 3 Vacuum Cycle & Dry Cycle • 22 Ltr Capacity And Micro Processor Controlled • Wrapped / Unwrapped, Porous, Solid Instrument Including Cotton Swabs Can Be Sterilized • Bow & Dick Test Qualified • Digital Display Of Pressure & Temperature • Double Safety Lock On The Door • Silicon Gasket Prevent Any Leakage Of Air • Can Be Used At ( 121 C & 134 C ) During Sterilization • 2 Storage Tanks For Fresh And Used Water • No. Of Tray 3 , Automatic Pressure Hand Piece Cleaning Machine , Automatic Radiographic Film Processors , Automatic Shade Analyser Equipment That Relates To A Computer Readable Medium Comprising One Or More Programs For Carrying Out A Method For Determining A Patients Tooth Shade, Compatible With Vita Shade Guide , B.P. Handle, Straight, Rounded, Angled Rounded, Straight Flat No. 3& 4. , Ball Burnisher , Band Forming Plier , Base Former Made Up Of Rubber Base, 2Sets Maxillary And Mandible , Bearing For Lab. Clinical Merathon Micromotor &Conventional Straight H / P / , Binocular Microscope ?Ergonomically Design Retro Styled U Shaped Stand In One Piece Die-Casting. Reverse Nosepiece Binocular Head Inclined At 45; Ensure Comfort During Prolonged Usage With High Precision Collimation. Ipd Adjustment Provided Between 54Mm And 74Mm. ? Adjustment Available On One Tube For Length Compensation With No Effect On Performance. All Prisms Have Hea Coating For Maximum Light Throughout And Exact 50 / 50 Light. ? Eyepiece: - 10 X Wf ( Fov 20Mm ) Has Expanded Wide Field Of View Through High Eye Point 25Mm With Foldable Eye Guards. ? Objectives Plan Achromatic Objective 4 X, 10 X, 40 X ( Sl ) And 100X ( Sl, Oil ) Give Excellent Performance. ? Double Plate Flat Top Mechanical Stage With Low Positioned Co- Axial Controls. The Plate Size 160Mm X 140Mm. ? Sub Stage Condenser Na 1.25 Pre Centered With Aspheric Lens And Day Light Blue Glass Filter. ? The Illumination System Has 6V- 20 W Halogen Lamps With Variable Control, Built In Base, Housing All Electrical Inside. ? Packed Kin Wooden Box ( With Lock And Key ) And With Instruction Manual And Dust Cover. With Colorcorrected Infinity Optical System Consisting Of Infinity Optical System Antifungal Optic Microscope Stand Binocular Eyepiece Tube Siedentop Type Inclined Wide Field Higheye Point Eyepieces Wf10 X / 20Mm Pair Reverse D Quadruple Nosepiece. , Biochemical Analyzer ( Semi Automatic ) Semi Automated Chemistry Analyzer-Capable Of Performing Routine Biochemistry Tests Including End Point, Various Enzymatic ( Kinetic ) , Fixed Time With Multi Standard Curve Calibration Open System. Program Mode: Absorbance, Bi Chromatic End Point With Standard Or Factor, With Or Without Reagent Blank / Or Sample Blank. Should Have Minimum 6 Filters With Range 340 To 670 Nm. Halogen Lamp 12V 20W & Should Have Lamp Saver Mode. Photometric Range From 0.0 To 3.0 A Peltier Controlled Flow Cell Chamber With Flow Cell Of 18Ul With Temp From 20 To 40 Degree Celsius At Increment Of 1 Degree Celsius Aspiration System: In Built Peristaltic Bi Directional Pump ( Air Purge Between Samples ) Memory General Operating Software For Storage Of Calibration Curve & Absfor Reagent Blank For End Point Methods. Multi Standard With End Point / Kinetics / Fixed Time For Minimum 9 Standards. Triplicate Mode Of Calibration And Triplicate Mode Of Sampling With Mean And Sd. Display: Large Graphic Lcd & Thermal Graphic Printer For Printing Of Reaction Curves & Test Results & Laboratory Name And Doctor’S Name. Should Have On Line Graph And Od And Also Graph Should Be Edited To Remove The Non Linear Portion. The Software Should Be User’S Friendly And Inbuilt Profile Calculators For Lipids, Iron / Tibc Etc. Should Have Input Voltage- From 220 V / 50 Hz. Should Have Triple Cuvette System : Cuvette / Flow Cell For Biochemistry And Round Tubes For Coagulation. Reaction Volume: 100 To 1000Ul. Should Have Pt With Inr, Ratio & % Values For The Results. Should Copy, Delete And Edit Function For Easy Programming Of Test Methods. Should Have Minimum Storage Of 5000 Testin The Memory With Patient Id. Should Have Inbuilt Feature Of Inventory For Reagent Management. Should Have Usb Keyboard Connection. Operator Interface: Membrane Keyboard For About 35 Keys For Direct Test Selection Quality Control Should Have Minimum 30 Results With 3 Levels. Should Have Inbuilt Dry Bath Incubator With Inbuilt Individual Timers. , Biopsy Equipment , Bite Planer , Bite Positioner Bioplast Material, Sizes Small Med And Large. , Bone File , Bone Gouge ( Medium ) , Bone Gouge ( Small ) , Bone Gouge Large , Bone Nibbler 6” & 8” ( Singleleaver ) , Bone Nibbler 6” & 8” ( Double Leaver ) , Bone Plate Self Screw Holding 1.5Mm Driver , Bone Plate Self Screw Holding 2.5Mmdriver , Bone Plate Self Screw Holding 2Mm Driver , Bone Ronger , Bowl Steel ( Small & Medium Size ) , Boyles Apparatus Construction Should Be Tubular, Rigid, Electrostically Powder Coated Steel Section, Gas Specific Yokes With Sliding Steel Claming Bars, For Mobility 4 Large Diameter Anti Static Castre Wheels, 2 Pressure Gauge& Regulatoreach For Oxygen & Nitrous Oxide, Non Return Pressure Release Valve, The Ofwd ( Oxygen Failure Warning Device ) , Space For 2 Or More Vapouriser Long Flowmeters ( Approx.230Mm ) , Oxygen Flush, Circle Absorber, The Basic Machine Should Be Isi / Ce Marked. , Broadrick Occlusal Plane Analyser , Bucks Periodontal Knife , Bulb For Light Cure For Tungsten Halogen Curing Lights 300 Mw / Cm2 Or Higher , Bunsen Burner For Use With Butane Gas / Lpg , Bur Box , Burn- Out Muffle Furnace * Programmable, Pre Set System * Microprocessor Controlled Temperature Regulation With Digital Lcd Display * Heating Upto 1100`C * Mold Chamber Dimensions * Height- 100 -150Mm *Depth- 250-350 *Width- 200-250Mm * 230V / 50Hz / 2300 Watt , Camera ( Dental ) • Compact Digital Still Camera With Twin Flash And Ring Flash, 5X Optical / 4X Digital / 20X Combined Zoom With Optical Image Stabilizer System • Monitor ( Min ) -2.8-Inch Tft Color Lcd ( Vari-Angle Type With Wide Viewing Angle • Resolution ( Min ) - 10 Megapixels • Viewfinder Type-Real-Image Optical Zoom • Focal Length-6.1 ( W ) - 30.5 ( T ) Mm ( 35Mm Film Equivalent: 28 ( W ) - 140 ( T ) Mm ) • Computer Interface-Usb 2.0 Hi-Speed Usb ( Dedicated Female Connector With Unified Type Of Digital, Audio And Video • Memory Card Support-Secure Digital ( Sd ) Card • Shutter Speed-15-1 / 4000 Seconds ( Total Shutter Speed Range; Varies Based On Shooting Mode ) • Power Sources-Rechargeable Lithium-Ion Battery And Ac Adapter Kit Other Features-2Gb Or More Memory Card Macro Ring Lite Mr-14Ex Conversion Lens Adapter User Guide / Instructions , Carbon Brush For Marathon Micromotor M3 , Casting Machine A. Centrifuge Motor Cast , Cats Paw Retractor , Cement Carrier , Cement Condensers , Cement Spatula , Ceramic Furnace – Fully Programmable Ceramic Furnace:- Firing Chamber Should Be Lined With High-Quality Insulating Material ??Molybdenum Disilicide Heating Elements ??Color Graphic Touchscreen Display ??50 Freely Programmable Sintering Programs. Safety Features That Should Be Present:- ??Temperature Sensor Monitoring ??Current Monitoring ??Protection Against Power Failure. Technical Requirements:- Dimensions: Firing Unit: W X H X D 360 Mm X 810 Mm X 490 Mm Power Unit: W X H X D 500 Mm X 210 Mm X 350 Mm Weight: Firing Unit: 32.0 Kg Casing With Power Unit: 27.5 Kg Firing Chamber - Capacity: Diameter : 84.0 Mm Height: 90.0 Mm Firing Chamber - Temperature: Max. 1600°C Electrical Requirements:- Power Supply: 200 / 230 Volt Ac 50 Hz 110 Volt Ac 50 / 60Hz Power Consumption: Max. 1500 Watts Classification: Safety Class 1 , Ceramic Kit ( Instrument ) , Chair Side Trolley ( Small ) , Cheatal Forcep 8” , Cheatal Forceps 10” , Cheek Retractor ( Small ) , Cheek Retractor ( Medium ) , Cheek Retractor ( Large ) , Chip Syringe , Chisel , Circular Saw , Clinical Micromotor With St. & Contra Angle Hand Piece Motor Of 35000Rpm. With Control Box & Foot Control , Coll Tubing For 3- Way Syringe& Airotor H.P. , Composite Finishing Instrument Gold Plated , Composite Placement Instrument Kit Terflon Coated / Non Sticky Surfaced Instruments For Placement Of Composite , Composite Polishing Kit , Compressor Centralized Compressor System. Compressed Air System For 11 Dental Chairs And Maximum 11 Operators Working Simultaneously Clinic Pressure Station P 6000 400 V, 50 / 60 Hz, 8.6 -10.7 Kw, 22.5-25.5 A With 2 Aggregates, Incl. Control Unit, Air Intake Bacteria Filter, 500 Litre Pressure Tank And Refrigerant Dryer, Elec. Cyclone Separator, Relieve Valves, 100 % Duty Cycle, Remote Control Display Possible. Designed For Up To 30 Workplaces For Max 20 Operators Working Simultaneously. Voltage 400 V ( 3~ ) Frequency 50 / 60 Hz Output At 5 Bar With 2 Aggregates 1133 / 1280 L / Min Separate Control Display ( 5922-520-51 ) For Each Machine Room Required Dimensions Compressed-Air Station: H 180 X W 130 X D 100 Cm Dimensions Receiver / Dryer Station: H 210 X W 90 X D 180 Cm Technical Specification: Number Of Compressors Set Of 2 Compressors Treatment Stations At 60% Sim. 50 / 60, At 100%. 20 / 30 Voltage V 400 / 3N / Pe / Ac Frequency Hz 50-60 Rated Current A 22.5 / 25.5 Power Consumption Kw 8.6 – 10.7 Kw Fuse A 40 Characteristic C / D According To En 60898 Electrical Connection Ø Mm² 6 The Diameter Of The Power Cable Must Take Into Consideration The Voltage, Length Of Cabling And The Local Situation. Rpm Min 1500 Interference According To En 55014-1: 2003-09 Jamming Resistance According To En 55014-2: 2002-08 Protection Type Ip 20 Protection Class 1 Sound Levels Db ( A ) 91 Without Silencing Cabinet Duty Cycle %Ed 100 Net Weight: Kg 535 Without Silencig Cabinet Start-Up Pressure Bar 6 / 6.5 / 7 Switch-Off Pressure Bar 7 / 7.5 / 8 *Adjustable Using A Key-Operated Switch Safety Valve Bar 10 Tank Volume L 500 Performance At 5 Bar L / Min 1133 / 1280 Temperature Range In Operation +10 To +40 °C ( Ideal +25 °C, With Regard To Life-Cycle Of Compressed Air Station And Build-Up Of Condensation ) Storage And Transport -10 To +60 °C Relative Humidity In Operation Max. 70% Relative Humidity Storage And Transport Max. 95% ( Without Condensation ) Compressed Air Outlet Connection G1" Internal Threading Central Air Suction Connection Dn 70 Condensate Connection Dn 50 Condensation Volume 150-210Cm³ Per Condensate Drain Cycle, Depending On Temperature And Relative Humidity Required Room Ventilation M³ / Min 30 Dimensions P 6000 ( H X W X D ) Compressed Air Module Cm 180 X 130 X 100 With Silencing Cabinet Cm 210 X 140 X 125 Tank Module Cm 210 X 90 X 180 Required Distance Between The Tank And The Compressed Air Module Ca. 30Cm Total Required Space ( Including Access ) Cm 210 X 400 X 300 Supplier Has To Connect The Compressor To Dental Chairs. Turn Key Basis. , Compressor 1.0 H.P. Oil Free Imported Head ( With Indian Tank ) Silent Oil Free Air Compressor Which Produces Super Clean Airflow And Gives You A Very Comfortable Low Noise, Working Easy To Operate And Safe To Use, Oil Free Imported Head With Double Pistons Compressor With Indian Tank Supply Voltage 220V Ac 50Hz, Electric Current 24A, Frequency 550W, Power 70L / Min, Capacity 0.8 Mpa, Discharge Noise 56-65 Db , Compressor Head Noise Less ` , Condensor ( Round ) , Conebeam Computed Tomography ( Cbct ) Extra-Oral X- Ray System For Dental 3D Imagine Including Dedicated 2D Pan & 2D Ceph Modalities Hardware Should Have Bitepiece, Chinrest ( For Opg, Tmj, Sinus ) Sub Nasal Support, Temple Support Chin Support And 3 Laser Light For Easy & Comfortable Patient Positioning Of Standing And Wheel-Chair Patients. The Unit Should Acquire Images With 360- Degree Rotation For 3D. Should Have Color Touch Screen Graphic User Interface ( Minimum 10 Inches Or More ) For Program Selection & To Indicate The System Stats For Easy Operation With Patient Facing The Operator. Should Have Scout View Facility For 3D Examination. Unit Should Have Separate Sensor For Pan & A Separate For Cephmodality. Should Have Multiple Fov With Diameter & Height Of Minimum 6X6 Cms To 15X18 Cms Or More ( Choice Of 8 Or Ore Fovs ) . Should Have Minimum 75 Micron Voxel Size & Up To 400 Microns For Larger Fov. Should Have X-Ray Generator With Range Of 60-90 Kv And 2-16 Ma. Should Have Focal Spot Size Of 0.5 Mm According To Iec 336 Or Less. Should Have 3D Sensor Of Flat Panel Amorphous Silicon Technology Or Ccd / Cmos. Should Have Ccd / Cmos Sensor For 2D Pan Imaging. Should Have Ccd / Cmos Sensor For 2D Pan Imaging. Should Have Multiple Pan Examination And Including Full Opg, Half Opg ( Left & Right ) Bitewing , Maxillary Sinus ( Lateral & Pa ) Tmj Scan ( Lateral & Pa ) . Should Have Multiple Ceph Examination And Including Ap & Pa Ceph, Lateral Ceph, Submento- Vertex Scan Should Have Various 3D Programs Including High Resolution Endo Volume ( 4X4 Cm Or Smaller ) Implant Volume ( 10X10 Cm ) Craniofacial Volume ( 16X18 Cm Or Larger ) Etc. Mar Application Software Should Have User Specific Area Cross Section Planning-Curved / Liner Should Have Presets For Multiple 3D Rendering 3D Clipping / Cropping Facility From All Views ( Front-Back / Right-Left / Top-Bottom ) Variable Cross Section Thickness Should Be Available Facility To See Volume In 2D-Coronal, Sagittal And Axial View In Single Windows Text Drawing, Distance & Angle Measurement Overlay Facility On Images Should Be Available Should Be Possible To Do Implant Planning In The Same Software. Customizable Report Layout With Facility To Store Different Report Formats Should Be Possible. Should Have Facility To Convert Dicom Into Stl Format. Should Have Dicom Print Facility In The Software. Viewer File Generation Should Be Possible In The Software Other Essential Requirements Suitable Computer With Following Specs Processor Intel I7 9Th Gen Or Higher Ram 16 Gb 1Tb Ssd Dvd Writer Drive Keyboard & Mouse Monitor 24 Inch Full Hd With Hdmi Input Graphics Card Ati Radeon Rx 570 With 4 Gb Ram Or Equivalent Original Operating System Windows 10 Pro 64 Bit Online Ups For Units & Computer Minimum 5 Kva With 10 Mins. Backup. Suitable Dicom Printer With 1 Online Tray And >300 Dpi Print Resolution. Should Provide 100 Films Of Size 8X10 All The Equipments Supplied Including Printer Should Be New And Not Refurbished & Manufactured Not Before Tender Publishing Date. Warranty / Guarantee Of Cbct Unit For 5 Years From The Date Of Supply Unit Should Have Valid Aerb Type Approval With Validity Before Tender Publishing Date. Should Quote For Amc / Cmc For 5 Years After Warranty Period Should Provide Order Copy Of Quoted Model In Any Reputed Governments Institute. The Order Should Not Be Older Than 3 Years From The Date Of Tender Publishing Date. , Cord Packer ( Serrated And Non Serrated ) , Cordless Led Light Cure Light Cure Unit Type With Cooling 1300 M / W / 59 Cm. With 4 Cooling Modes ( Ramp Fast, Long & Plux ) Powerful Lion Battery- 4000 Sec.Work , Core Carrier Thermoplastic Obturation System Obturation System To Obdurate Root Canal Using Warm Compaction With Core Carrier , Coss-Bar Elevator , Cotton Holder , Cotton Waste Reciver , Coupland Elevator , Coupling With Nozzle For Airotor H.P. 2 Hole. , Cow Horn Forceps Upper , Cow Horn Forceps Lower , Crimpable Hookplacement Plier , Cryer Elevator , Cumine Scaler , Curette Lucas ( Small ) , Curette Molt ( Medium ) , Curettes –Universal And Gracey No. 1 To 14 ( Hu-Friedy / Medsey / Equinox ) , D S Carver , Debonding Plier , Deflasking Press ( 095-050 ) , Demonstration Models:- Partially Dentate Model Jaws For Prosthetic Exercise: Upper Class I Class Ii Class Iii Mod.2 Class Iv Lower Class I Class Ii Class Iii Mod.2 Class Iv , Dental Air Polishing Unitwith Both 27 Micron And 50 Micron Sand • Water Supply Pressure 0.2Mpa-0.4Mpa • Air Supply Pressure0.2Mpa-0.3Mpa • Max Water Spraying: 0.2Ml / S • Max Sand Spraying: 0.03G / S Compatible With Both 27 Micron And 50 Micron Sand , Dental Chair Pediatric Dental Chair •Body Contoured Electrically Operated Zero Programmable Chair ( Optional Multi Programmable ) •Sensor Operating Light With Two Intensity. •Chair Porcelain Spittoon •Vacuum Suction : High & Low •Chair Mount Unit Modular Delivery System - Hanging Cords. •Airotor - Two Points •Choice Of Hand Piece : Titanium Cellular Optic Fiberoptic, Ultrapush. Super Torque, Miniature & Standard •Micro Motor : Mighty 35000 Rpm / •Three Way Syringes - Two Nos. •X-Ray Viewer •Multi Functional Foot Control , Dental Chair .Electrically Operated Dental Chair Mount Unit 1. Electrically Operatedmicro Processor Based Multiprogrammable Dental Chair. 2. The Chair Should Have Erasable Programs With Microprocessor Controlled, Where Doctor Can Set His Ownprograms.The Program Switch Should Befitted To The Instrument Tray.Program 0Andgargling. 1 & 2 Erasable Program 3. Body Converging Movement Head Rest Of Chair Automatic Motorized Up & Down Movement For Perfect Adjustment Having Switch At The End For Stopping 4. The Right Side Arm Of The Chair Has Lateral Rotation For Easy Access Of The Patient. Chair Mount Unitfitted With: At 80 Cm Distance + 15% A ) Led Light With 3 Intensity With 3 Axis Movement, 40, 000 To 45, 000 Lux , Maximum Power Consumption Should Be 4 To 6 Watts. • On / Off By Sensor Switch Non-Touch • 3 Step Intensity Control By Non-Touch Sensor B ) Auto Water Connectionfor Spittoon And Tumbler. Basin Should Be Fabricated Out Of Non Rusting Aluminum Metal Plastic With Painting A ) Stainless Steel Instrument Tray For Keeping Instruments. B ) Led X-Ray Viewer C ) Monitor Mounting Arm With The Integrated Wiring F ) High & Low Vaccuum Motorised Suction: Noise Free, Which Consists Of High Vacuum And Lowvacuum With Flow Control Valve With Auto Start.The Fluid Collection Containerhasauto Drainsystem And Also Auto Flush System.Amalgam Collection Filter. Modular ( Delivery Systemover Patient ) Fitted With: A. Airotorcontrol Only I ) Micromotor ( Kavo / Nsk / Sirona / W& H ) Micromotorbrushless Speed Range 2000-40, 000 Rpm.With Digital Display Of Speed Should Be Supplied With: I ) Contrangle Handpiece –Autoclavable Speed 40, 000 Rpm1 No Ii ) Straighthandpiece –Autoclavable Speed 40, 000 Rpm 1 No C.3 Way Syringe For Air , Water & Spray 2 Nos One For Doctor And One For Assistant Zero Back Ache Stool :Should Be Most Latestsurgical Stool Having Raising And Lowering By Pneumatic Piston With Chromium Plated Legs. Back Rest Should Move Forward And Backward Along With The Body By Pneumatic Piston And It Should Give Support All The Time.The Seat Should Have A Piston To Move With The Body When A Surgeon Leans Forward. , Dental Engine For Clinical Work , Dental Engine For Laboratory Work , Dental Implant Maintenance Kit Along With Plastic Coated Scaler And / Or Plastic / Teflon Coated Curret Set , 2 ) Dental Implant Systemthe Complete Kit With Instruments &Implants And Physiodispensorwith Handpiece 2.1 Secification For Dental Implant Instruments • Complete Implant Surgical Kit • -2.00 Mm Sharp Point Internally Irrigated Pilot Drill. • Sequential Width Increasing Drills With Internal Irrigation • -Drill Extension With Internal Irrigation • -Surgical Ratchet / Wrench With Adjustable Torque 2.2 Specification For Physiodispensor Along With Handpice. • -Main Unit Should Be Capable Of Independent Control • -Should Be Possible To Switch Motor On / Off From Main Unit Without Touching Foot Switch. • -Should Be Possible To Switch Pump On / Off Form Main Unit Without Touching Foot Switch. • -Foot Pedal Should Have Dynamic Speed Control • -Variable Large Settings From 5-60 N Cm Should Be Available • -20:1 Torque Controlled Implant Surgery Handpiece 2.3 Threded Inplants And Coated Implants. , Dental Lathe Machine * Hp-1 / 2 * Rpm-2800 * Equipped With Double Ball Bearing, Single Speed, Continuous Rating, Three Chucks ( Buff, Bur Chuck, Shone ) , Dental Tweezers Rust Proof, With Serrated Working End , Dentist Stool Low Back Support, Physiologic Stools , Dfs Ceramic Brush No 6& 8 , Dfs Pindex System , Dfs Ring Less System , Dg 16 Endodontic Probe , Digital Auto Pipettes Fixed Volume ( Autoclavable ) ? Volume10 Micro Liter ? Accuracy + - 0.9% ? Precision- 0.4 Cv% , Digital Auto Pipettes Fixed Volume ( Autoclavable ) ? Volume20 Micro Liter ? Accuracy + - 0.9% Precision- 0.4 Cv% , Digital Auto Pipettes Fixed Volume ( Autoclavable ) ? Volume- 50 Micro Liter ? Accuracy +- 0.6% Precision -0.4Cv% , Digital Autopipetes Fixed Volume ( Autoclavable ) ? Volume- 100 Micro Liter ? Accuracy-+ 0.3% Precision- 0.3 Cv% , Digital Autopipetes Fixed Volume ( Autoclavable ) ? Volume- 1000 Micro Liter ? Accuracy-+ 0.3% Precision- 0.3 Cv% , Digital Magnetic Hot Plate Stirrer Sku La.Ma.1579767 Type Of Product Digital Magnetic Hot Plate Stirrer Max. Stirring Quantity ( Water ) ( Liters ) 3 Ltr Voltage 100-120V Ac / 200-240V Ac Dimension Of Top Plate ( Mm ) 5 Inch Motor Rating Input / Output ( W ) 5W / 3 W Speed Range ( Rpm ) 100 - 1500 Rpm Speed / Temperature Display Led Top Plate Material Stainless Steel With Ceramic Coated Hotplate Heating Power ( W ) 500 W Temperature Range 5-40°C Dimensions ( Wxdxh ) ( Mm ) 150X260x80 Mm Frequency 50 / 60 Hz Control Accuracy Of Heating Temperature With Pt-1000 ±0.5 External Temperature Sensor Pt-1000 Weight ( Kg ) 1.8 Kg Protection Class Acc. To Din En60529 Ip21 Power 515 W , Digital Multichannel Pipettes 8 Channel 12 Channel , Digital X- Ray Single Drawer Printer For Opg Machine Having True Laser Technology With Minimum 250 Laser Pixels Per Inch. 50-100 Micron Laser Spot Spacing, With 64 Bit Pixel Depth Architecture. Through Output Of Minimum 50-100 Sheets Per Hour ( Size 8X10, 11X14, X10x12 ) Printer Should Be Small In Size. Compatibility With All Kind Of Dicom File For Printing. Fast Printing And Compatible For Opg, Cbct, Ct, Mri Machine , Dingmann’S Retractor ( Pedo ) And Blade , Diode Laser Unit Wavelength 810 / 940 / 980 Nm Power -0 To 7 Watts , Dippen Dish , Dissecting Scissor Straight 4” , Dissecting Scissor Straight 6” , Dontrix Gauge Upto 16 Oz. Markings, Autoclavable And Grooved Markings, Calibration In Oz. And Gms. , Double Disk Model Trimmer With Diamond Disk, Carborandum Disk And Model Trimmer With Diamond Disc And Carborandum Disk •?Should Have Approximately Hp 1 And 2800 Rpm •?Should Be Ergonomically Designed, Heavy Duty, Low Noise, Single Speed •?Should Have Diamond Wheel Size 10” •?Should Have Automatic Water Valve With Water Spray Attachment And Splash Shield •?Should Have Orthodontic Work Table Complete •?Should Have Foot Switch •?Should Have Provision Of Both Dry / Wet Trimming Source: Indigenous / Imported. , Dressing Drum ( Medium ) 11”X9” For Autoclave , Dressing Drum ( Small ) 9”X9”For Autoclave , Duplicating Unit , Duplicator Equipment , Electro Cautery Monopolar Generator Frequency 500+25 Khz Cut Control . Scale Pure 375 + 10 W.500 O Load.Cut Control Full Scale Blende 250 + 10 W. 500 O Load Coag Continuous Blending Through Hemostasiscontrol 125 + 15 W Bipolar Genearator ( Frequency 650 + 25Khz ) Output Level 70+5 W. 125 O Load Power 230 V +5 % 50 Hz Size 480X290x180mm Weight 15 Kg Applications : For All Type Of Major Surgery Includes Under Water Cutting T.U.R &For Bipolar Micro Coagulation, Ce / Iso Certified , Electro Phoresis System Vertical And Horizontal Gel Electrophoresis The System Should Use Disposable Sample Applicators For Applying The Samples Using Capillary Action. Samples Should Not Be Directly Applied On Gel By Pipette. The System Should Be Able To Use Agarose Gel As Matrix For Migration With Capacity To Process 7 Samples At A Time. The System Should Be Manual Electrophoresis System. The System Should Be Able To Perform A Test Menu Of Serum Proteins, Lipoproteins, Haemoglobin’S In Acid And Alkaline Ph, Iso Enzymes Of Cpk, Ldh And Alkaline Phosphatase, High Resolution Proteins, Serum And Urine Immunofixation. Electrophoresis Tank Should Have Platinum Electrodes. The System Should Have Incubator Dryer For Fixation Of Proteins Eliminating The Need Of Acetic Acid Fixation. System Must Have The Latest Software Which Should Be Windows Xp Compatible For Complete Data Control, Graphics, Graph Corrections. Graph Overlay And History Recall. Patient Reports Should Be Printed Out With Electrophoretic Graph And Pattern. Patient Search, Input And Archives. It Should Have Good Q.C Functions. Software Should Be Compatible With The Gel Scanner. Software Should Be Able To Store Upto 100, 000 Electrophoretic Curves And Upto 4000 Immunofixation Reports. Software Should Have Bidirectional Lis Capabilities. Power Supply For The Electrophoresis System Should Be Programmable With A Memory Of 6 Programs. Voltage Range Should Have Be Ranging From 5 – 300 Volts For The Power Supply Of Electrophoresis System. Current Range Of 0 – 200 Ma For The Power Supply For The Electrophoresis System. Power Setting Of 0 – 60 W For The Power Supply For The Electrophoresis System. The Electrophoresis Power Supply Should Have 2 Outputs 2 Connect 2 Electrophoresis Tanks Simultaneously. The Electrophoresis System Should Have An Electrophoresis Chamber Without Paper Wicks And The Gels Should Dip Directly In The Buffer For Direct Contact. Tank Should Have Safety Lock. The Incubator – Dryer Of The Electrophoresis System Has Tangential Air Flow For The Fast And Homogenous Drying. The Incubator - Dryer Of The Electrophoresis System Has Temperature Settings Of 37° C, 51° C & 80° C. The Electrophoresis System Comes With Complete Gel Accessory Kit With 5 Vessels With Cover, 3 Double Gel Holders, Vessel Support And 2 Incubation Boxes , Electronic Needle Destroyer , Electronic Orthodontic Spot Welder & Solderewith Variable Welding Power Control Having Optimum Electric Adjustment Of Welding Pulse At All Welding Currentstrength. Complete With Hand Electrodes Solder Holding Device With Power Rating 300 Va Pulse Current 1000A, To Work On 220-260 Volts 50 , Elevator Periosteal , Elevator Warwick James Curved , Elevator Warwicks James Straight , Emergency Medicines Kit , Enaemal Hatchet , Enamal Tray , Endo Block Endodontic File Rubber Stop Length Measuring Device During Root Canal Treatment , Endo Box Autoclavable Box For Holding Endodontic Instruments , Endo Instrument Removal System System Used To Retrieve The Separated Instruments From Root Canals , Endodonticnegative Pressure ( Vacuum ) Irrigation System System To Irrigate Root Canal In Which Negative Pressure ( Vacuum ) Pulls Micro Particles Out Of The Root Canal System , Endodonticsilver Pointsretrieval Forceps ( Stiegitz Plier Or Like ) Forceps To Retrieve Silver Points From Root Canals , Endodontic Microsurgery Kit Having The Following: • B.P. Handle • Periosteal Elevator • Surgical Curettes • Endodontic Excavator • Root Canal Pluggers • Tissue Holding Forceps • Needle Holder • Surgical Scissor • Micro Mirror • Plugger / Condenser • Burnisher • Plastic / Placement Instrument Retractor , Endodontic Operating Microscope • # Floor Mount Sturdy Heavy Stand For Counter Balance And Castor Wheels With Lock • # Led Illumination ( Minimum 100K Lux ) Through Fiber Optic And Controls Within Reach Of Operator • # Apochromatic Stepless ( Zoom 6:1 ) Magnichanger With Provision To Change To Step Magnification. Magnification From 0.4X-2.5X • # Magnichanger Carrier With Electromagnetic Clutch System For Positioning View Head Angle At Desired Angle. Single Hand / Button Operation User Friendly For Left Or Right Hand Controls • # Ergonomic Inclinable Observation Head, Preferably 0 Degree To 210 Degrees • # Green, Blue, Heat Absorbing In Built Filters • # Swivel Arm And Suspension Arm With Movement Locking Knob • # Common Main Objective Must Be A Variable F, Preferably 300 To 400 • # F 170 Binocular Viewing Tilting Head With Wide Field Eyepiece 10X And 12.5X, Focusable • # Double Beam Splitter With Extension For Sitting Comfort And Dual Iris # Along With Inclined Beam Splitter With Dslr Camera Adapter With Latest Dslr Camera And Led Monitor , Endomotor With Handpiece With Rotary And Reciprocating Motion, Torque Control, Multi Programmable Capability, Auto Reverse Feature. , Excavator Spoon Shape , Ext.Tooth Forceps ( Lower Anterior ) , Ext.Tooth Forceps ( Lower Molar ) , Ext.Tooth Forceps ( Upper Anterior ) , Ext.Tooth Forceps ( Upper Molar ) , Extra Oral Cassettes With Intensifying Screens ( Conventional &Rare Earth ) , `Forceps Mosquito 5” , Formalin Chamber Clear, 15 Ltr. Capacity With 3 Level Trays , Fox Plane , Galveno Coping Unit , Gas Torch Adjustable Flame Size, Butane Refillable, Melts Solder, Gold Solder, Gas Volumne:Min 35Ml, N, W:Min 120G, Flame Tempreture 1300 / 2450F, With Function Of Locking Fire, Electronic Ignition , Gear For Nsk Nac-E Contra Angle Hand Piece , Gigli Saw Holder , Gigli Saw Wire , Glass Slab , Goldman Fox Probe , Heavy Wire Cutter With Tungsten Carbide Tip , Hilton Sinus Forceps , Histopathology Slide Storage Cabinets Pathologic Biopsy Slide Storage Cabinet With Distinctly Separated Shelfs For Individual Slide ( Woodenor Plastic Or Metallic ) External Dimension:405Mm ( L ) *478Mm ( W ) *375Mm ( H ) , Including Three Units, Each Unit Contains 6 Large Drawers, Each Large Drawer Contains 2 Strips Spcc Stainless Material, Thickness 0.8Mm Cold Rolled Sheet. ( Approx Features; Few Alterations Is Acceptable ) Total Capacity: Approx.10000 Slides , Histopathology Wax Block Storage Cabinets Wooden With Slots In Separated Divided Drawers For Proper Placement Of Waxblocks Total Capacity: Approx.10000 Blocks , Hot Air Drying Cabinet , Hot Air Oven , Howarth’S Periostal Elevator , Hydraulic Bench Press × Working Pressure-200 Atm × Test Pressure-400 Atm ×With Pressure Relief Valve , Hydro Solder Unit Compact With Maximum Gas Production Up To 80 1 / B Main Connetion Voltage 230 U / 50 Hz 2-1 Reactor And Nickel Electrode No Necessity For Changing Electrodes. Through Compliance With Safety Regulator , I.O.P.A. X- Ray Machine Compatible To Rvg With Following Features On Wheel / Wall Mounted Aerb Approved, Safety Feature As Per Aerb Norms Focal Spot 0.7 Mm / Or Less Tube Current 60Kv – 70 Kv Wall Mounting / Mobile, Floor Standing Dual Installation Layout : Remote ( Close To The Unit Or Outside The Treatment Room ) Or Integrated To The Unit Automatic / Manual Time Setting, Film Or Digital Mode Syncronisation Link With Rvg Systems, Collimators ( Size A, B, C ) Long Cone ( 30 Cm / 12In ) Soft Positioning Arms For Accurate Tube Positions Lightness And Flexibility In The Movements Head Tube And Cone Are Insernally Lead Coated To Avoid Scattered Radiation High Voltage Generator With High Efficiency In The Emission Of The X-Rays Digital Control Equipped With An Easy Ready Display Indicating With Precision The Selected Timeexclusive Angular Indicating System For Head Positioning In Various Radiographic Techniques High Efficiency And Greater Sharpness Of The Radiography, Shorter Exposure Time And Greater Safety Double Pantographic Arm With Vertical And Horizontal Smooth Movements , Illuminated Mouth Mirror & Probe , Induction Casting Machine , Injectable Gutta Percha Obturation System With Downpacking And Back Filling ( 23 And 25 Gauge ) Capabilities. , Injection Moulding Flasking Unit , Instrumenttrolly ( Cross ) , Instrument Cabinet , Instrument Trolly ( Side ) , Intraoral Camera With Display System Sensor Micron 1 / 2.5 Cmos 2592 ( H ) X 1944 ( V ) Video Resolution 640 ( H ) X 480 ( V ) Image Resolution 1024 ( H ) X 768 ( V ) Focus Range 1 Mm - Infinity Angle Of View 90° Field Of View 80° Focus Autofocus Light Source 8 White Led Array Video Output Usb 2.0 Tv-Ntsc Tv-Pal S-Video Vga Wireless Technology Wifi-Transmission Range 10 M , Iontophoresis Unit For Treating Dentinal Hypersensitivity , Kidney Tray Large , Kidney Tray Small , Kocher Curved Forcep 8” ( Large Size ) , Kombi Duplicating Flask- Plastic , Lab Centrifuge Revolutionary Microprocessor Lab Centrifuge With Brushless Induction Motor And Frequency Drive. Digital Display Of Speed & Time Stepless Speedregulator 0-60 Min Digital Count Down Meter. Imbalance Detector Safety Lid Interlock To Prevent Cover Opeing During Centrifugation. Max Speed: 5250 Rpm Max Rcf: 3600 G Max Capacity: 400Ml Supplied With 24X1.5Ml Rotor Head Temp And Humidity Controlled With Digital Display , Lab Micromotor A. With Heavy Duty Handpiece B. Corbon Bush Less , Lacrimal Probes , Laryngoscope With All Side Blade 4 Different Size For Standard Blades 1 Handle For Pediatric & Adult Seapartely & 1 Short Stubby Handle, Ss Made Finish Curved Blades For Adult & Pediatric, Should Be Provided With Battery, Should Provide Spare Bulb 6 Nos. , Laser Pointer Bluetooth Enabled With Slide Change Tool , Lead Apron –Doctor For Protection Of Operator From Radiation Exposure , Lead Apron- Patient For Protection Of Patient From Radiation Exposure , Lead Gloves , Lead Screens , Led X-Ray View Box , Powder Coated Ms Cabinetwith Aluminium Frame 14 Inches X 17 Inches , Ligature Cutter With Tungsten Carbide Tip , Light Curing Unit, Plasma Arc 75 Watts, 12V Tungsten Halogen Lamp. Calibrated Automatic Timer From 10 To 60 Seconds. Autoclavable Fiber Optic Probe, 115V 60Hz Or 230V 50Hz Ac , Light Wire Plier With Tungsten Carbide Tip , L-Retractor ( Medium Size ) Langenback , L-Retractor ( Large Size ) Langenback , Luxator Set For Dental Extraction , Magill’S Forceps , Magnifying Glass , Marquis Color Coded Probe , Matrix System ( Sectional ) ( Palodent Or Like ) Used For Building Proper Contacts Between Teeth , Mc Call’S Curettes , Mekontosh Sheet , Metal Grinder , Metal Saw With Handle - 6 Inch And 12 Inch , Micro Needle Holder , Micro Scissor , Micro Surveyor , Microsurgery / Oscillating Saw Hand Piece Specification 1.8 Mmreciprocating 3:1 Reduction H. Piece With External Spray Nozel Max. Speed – 12600 Strokes / Min. With Blades ( Packet Of 10 Each ) 1. 10 Mm X .35 Mm Thickness 2. 20 Mm X .35 Mm Thickness 3. 30 Mm X .35 Mm Thickness 17 Oscillating 3:1 Reduction H. Piece With External Spray Nozel Max. Speed 12800 Strokes / Min With Blades 1 Each 30 Mm X ( .3 Mm X 10.5 Mm X 6Mm ) 45 Mm ( .3 Mm X 10.5 Mm X 6 Mm ) 30 Mm ( 15.5 Mm X 6.5 Mm X .3 Mm ) 45 Mm ( 15.5 Mm X 6.5 Mm X .3 Mm ) 30 Mm ( 15.5 Mm X 9.2 Mm X .3 Mm ) 45 Mm ( 15.5 Mm X 9.2 Mm X .3 Mm ) 3” Sagital Saw 3:1 Reduction With External Spray Nozel Max. 12600 Strokes / Min Blade Packets Of 10 Each ( 25 Mm X 6 Mm X .3 Mm ) , Millers Apexo Elevator ( Paired ) For Tooth Extraction For Tooth Extraction , Mouth Gag A. Heister Mouth Gag B. Fergussons Mouth Gag , Mouth Mirror , Mouth Mirror Handle , Mouth Mirror Top , Mouth Prop , Naber’S Probe , Nasal Hood For Inhalation , Needle Holder 4” , Needle Holder6” , Needle Holer 8” , Nerve Retractor , Nerve Stimulator , Newman’S Probe , Nitrous Oxide Oxygen Inhalation Unit Technical Specifications It Should Have- Table Rigid ( Trolley ) M.S. / Aluminum Structure Duly Electro Statically Powder Coated. Capacious Double Decker Drawer For Keeping Necessary Accessories Rust Free Castors With Brakes In Front For Easy Mobility. Stainless Steel Table Top To Keep Necessary Accessories. Flow Meter Bank Of Nitrous Oxide: 1 -7 Ltrs. / Min. Flow Meter Bank Of Oxygen: 1-10 Ltrs. / Min. A Maximum Total Flow> 17 Ltrs. / Min. Precise Flow Min 0.5 Ltr, N2o: 0 - - - 70 %, 02:30%---100% O2 / N2o Panel / Yoke Mount Pressure Gauges For Cylinder Tank. 02 / N2o Panel / Mount Pressure Gauzes For Line Working Pressure 2 Nos. Gas Specific Yokes To Fix A Type Nitrous Oxide Cylinders. 1 No. B Type Oxygen Cylinder Platform, Provision For Central Gas Supply Which Can Be Attached To N2o Yokes With Pin Index Block Type Hose & O2 Can Be Attached In Quick Release Valve. Standard Breathing Circuit 02 Which Is Provided Along With Nasal Mask. ( Autoclavable ) Patient Outlet Link: 15 / 22 Mm Bag Tee With Emergency Air Valve. Nitro Lock - Basic Safety Against Accidental Delivery Of Nitrous Oxide When Oxygen Meter Is Closed. Oxygen Failure Warning Device. ( O.F.W.D. ) Nitrous Oxide Failure Warning Device. ( N.O.F.W.D. ) Additional In-Built Regulators Should Be Provided For Both Gases To Prevent Excess Pressure Coming From Main Regulators Or Central Gas Supply In-Built Excess Pressure Relief Valve On Main Regulators. O2 Quick Supplement Not Less Than 17 Its. Min. T Safety Valve With Bag Tee. Std. Silicon Tubes ( Fresh Gas Inlet & Excel Gas Tube ) ( Auto-Clavable ) With Connector. 10 Each Nasal Mask ( Small, Medium & Large ) 02 Mox Regulator With Conversion Kit & Combination Spanner For B Type Cylinder 01 Set Flush Type Spanner For N2o Pin Index A Type Cylinder 01 Each. Seal Bodak Washers For N2o Yokes. Approximate Dimentions : ( H ) 1100 Mm ( W ) 510 Mm ( D ) 610 Mm , O Ring For Water- Booster Cap , Omega Loop Forming Plier , Optical Spectroscopy Instrument For Oral Cancer Detection , Orbans Periodontal Knife , Orthodontic Micro Implant Kit With Sizes Of Implant From 008 To 012 10 Implant Each, Implant Driver 1 Palatal, 1 Universal, 01 Punch Drill, 01 Guide Drill With Autoclavable Implant Kit Box , Otlight ( Led ) Halogen Ot Light ( Single Dome And Double Dome ) • Single Dome Ceiling Mounted Halogen Light • Epoxy Coated Fibre / Metallic Single Dome Size 525Mm • Dichroic Coated Glass Reflector • Shadow Less Cold & White High-Intensity Light With Colour Corrective Filter Glass To Minimize Heat. • Spring Balance Control System • Halogen Lamp 24V, 150W With Optional Secondary Lamp With Auto Switch On To Reserve Bulb Within 5 Seconds In Case Main Lamp Fails • Lux Output 1, 10, 00010% • Field Size 200-250 Mm Diameter • Sterilizeable Focusing Adjustable Detachable Handle Made Of Brass • 260 & 31 Arm Movement • Dome Tilting Angular 45, Lateral 60 • Power Supply Source Auto Cut Transformer / Cvt With Intensity Control • Input Power Supply Voltage 170V-260V For Double Dome Model Also, As Above , Oxygen Cylinder Large ( Jumbo With Mask Connection ) Made Of High Quality Strength Aliminium Alloy With Heat Sensitive Coating & Approved By And Certify By Deptt.Of Explosive Nagpur, Dot -3-Al-2015 Standard , Should Have Valve Safeguard, Color Code As Per Is : 3933-1966 / Iso With All Updating, Valve Should Be As Per Is: 3745-1948 , Palatel Trimmer , Paquette Blade Handle , Parrallelogram Condensor , Pentahead Microscope -01 , Perforated Impression Trays , Periodontal Probes – Unc-15, Goldman Fox Probe , Periodontal Surgeryinstrument Set - A- Kirkland Periodontal Knife 15 / 16 , No. ( Hu-Friedy / Medsey / Equinox ) B-Orbans Periodontal Knife1 / 2 No . ( Hu-Friedy / Medsey / Equinox ) C-Bucks Periodontal Knife 3 / 4 , 5 / 6 No. ( Hu-Friedy / Medsey / Equinox ) D.Krane Koplan Pocket Marker ( Hu-Friedy / Medsey / Equinox ) F-Tissue Nipper ( Hu-Friedy / Medsey / Equinox ) G-Cumine Scaler ( Hu-Friedy / Medsey / Equinox ) H-Mallet ( Hu-Friedy / Medsey / Equinox ) I-Oschenbain Chisel ( Hu-Friedy / Medsey / Equinox ) J- Schluger Bone File 9 / 10 ( Hu-Friedy / Medsey / Equinox ) K- Sugerman File 1S / 2S, 3S / 4S ( Hu-Friedy / Medsey / Equinox ) , Phantom Lab Unit ( Pre Clinical Work Station ) Phantom Table Fitted With Halogen Operating Light Phantom Head Body Type Neck Joint For All The Movement, Tmj Movement. Modular With Air Rotor, Micro Motor With Contra Angle Hps, 3-Way Syringe, Jaw With Ivorine Teeth, Preferably Soft Gingival, Dental Operator’S Stool ( Not To Use Extracted Or Cadaver Teeth ) . , Photographic Intraoral Mirror ( Front Surface ) , Piezon Ultrasonic Scaler With 7 Tips Model P3ii ( With Digital Display ) Power Selection Modes. Turbo For Fast Removal Of Hard Calculas & Tarter Scalling For Scaling Perio For Using Endodontic Kit. , Piezotome Unit 1 Hindpiece, Set Of 6 Bone Surgery Tips, Set Of 5Sinus Lift Tips, Set Of 6 Power Periotome Tips, Set Of 5 Intrlift Tips, 1 Large Sterilizationcassette, 2 Sets Of Autoclavable Tubing And 20 Irrigation Bag Spikes , Pindex System , Plain Screw Driver 1.5Mm , Plain Screw Driver 2.5Mm , Plain Screw Driver 2Mm , Plaster Dispenser •?Should Have A Capacity Of 20-30 Kgs •?Should Be Wall Mounted •?Should Have A Stainless Steel Body •?Should Have Inside Rubber Container To Prevent Dispersion Of Dust In The Environment •?Plaster Should Be Protected From Humidity And Other Polluting Elements •?Should Dispense Plaster In Dusty Powder Form •?Digital Electronic Timer Preferred. , Plaster Spatula , Pneumatic Chisel , Polishing Lathe , Pontic Formers Anterior & Posterior U.& L. Modules , Posterior Band Removing Plier , Potts Elevator , Pre Heating Furnace , Pressurised Local Anaesthesia System , Probes Right Angle , Pulp Tester ( Digital ) , Pulse Oxymeter With Audiolum , Punch Biopsy Set , Radiographic Film Storage Lead Containers , Radiographic Filters ( Conventional & Rare Earth ) , Radiometer For Measuring Light Intensity At Various Wavelengths , Real Time Pcr System The System Should Haveinbuilt Gradient 96-Well Peltier Based Block Capable Of Accommodating 96 X 0.2Ml Plates, Tube Strips And Individual Tubes System Should Have Provision Of Being Used As Conventional Gradient Pcr System Should Have Inbuilt Touch Screen Display And Option For Controlling Through Computer System Should Have Scanning Optics With 6 Filtered Leds As Excitation Source And 6 Filtered Photodiodes / Ccd Camera As Detection. System Should Not Require Any Periodic Calibrations System Must Be Capable Of Multiplexing 5 Targets In A Single Well System Should Have A Channel Dedicated For Fret Analysis Excitation / Emission Wavelength Range: 450-730Nm The System Should Have Inbuilt Gradient Range From Least 30°C-100°C With Gradient Differential Range Of 1-24°C And Capable Of Running 8 Different Temperatures Or More The System Should Have Maximum Ramp Rate Of At Least 5 °C / Second Or Better Block Temperature Range: 0-100°C, Uniformity ±0.4°C And Accuracy ±0.2°C The Instrument Should Have Dynamic Range Of 10 Orders Of Magnitude Or Better The System Should Include Software To Support Applications Like Relative Quantitation, Normalized Expression With Multiple Reference Genes Should Be Supplied With High Resolution Melt Analysis Software Software Should Have Option For Setting Up The Plate Before, During Of Even After Real Time Pcr Is Complete Software Should Have Reference Gene Selection Tool For Information On Which Reference Genes Are Likely To Be Expressed At Consistent Levels In Samples During The Run Software Should Have Option For Performing Allelic Discrimination, T-Tests, And One –Way And Two-Way Anova Software Should Have Provision For Automatic Data Analysis For Multiplate Studies ( Unlimited Cq Values ) Software Should Have Following Data Visualization Options- Bar Charts, Dot Plots, Box Whisker Plots, Scatter Plot, Clustergram, Volcano Plot Software Should Be Able To Generate Data Graphs In Jpeg, Png Or Bitmap Format As Per User Selected Image Size And Resolution System Should Have Option For Upgradation To 384 Well Block If Required In Future System Should Be Supplied With Starter Kit ( Hard Shell 96 Well Low Profile, Full Skirted Plates 50Nos, Sealers 100Nos And Sybr Green Supermix 200Rxns ) System Should Be Supplied With Compatible Computer And 2Kva Online Ups With 30Mins Back Up , Reverselangenback , Rib Cutting Forceps And Rib Shear Adult , Rib Cutting Forceps Shear Child , Rubber Bowl Small , Rubber Bowl Large , Rubber Dam Kits , Rubber Moulds For Casting Plaster Study Model Upper & Lower Edentulous Ridgesfully Denture Ridges , Rubber Moulds For Casting Plaster Study Model Upper & Lower Individual Tooth , Rubber Moulds For Casting Plaster Study Model Upper&Lower 1. Edentulous Ridges 2.Fully Denture Ridges , Rvg Rvg Is A Digital Imagin System, Which Allow Quick Or Immediate Viewing Of Image Without Using Dental X-Ray Film, Consist Of An Intraoral Sensor Or Imaging Plate, An X-Ray System, Computer Hardware And Software For Image Processing, And A Hard-Copy Printer Operational Requirments Rvg Sensor And The Computer System Along With Imaging Software Is Required. X-Ray Generator Is Not To Be Quoted Technical Specification A. Rvg Sensor System • Should Be Based On Cmos / Aps / Ccd • 8-30 Lp / Mm True Image Resolution • Exclusive Sensor With Compelete Software Package Including Optical Fiber Technology. • Plastic Pack Design To Allow Easy Periapical And Bitewing Radiograph • Usb Cable Preferably Wireless Sensor • Three ( Small, Medium & Large ) Size To Help Meet The Unique Imaging Needs Of Practice And Patients. • Thickness Of The Sensor Should Be 1-5Mm. • Sensor Life Should Be More Than 500000 Exposures. • Sensor Active Area Should Range From 450-1000 Square Mm For Different Sizes Of Sensor. • Rvg / System Software. 1.Should Be Licensed. 2.Should Have Facility For Rvg Well As Intra Oral Camera. 3.Should Have Automatic Acquistion And Save Facility. 4.Should Have Sharpening, Cleaning And Improving Feature. 5.Should Have Search Facility By Patient Id Name Or Any Other Criteria. 6.Should Be Internet Compatible. 7.Should Be Capable Of Generation Reports. 8.Should Be Capable Of Avoiding Accidental Deletion. B. Radiation Protection Accessories : Lead Apron, Thyroid Collar, Gonadal Sheath. C. Computer Hardware: 1.Should Be Intel Core 2 Duo Pentium Pc With 160 Gb Hard Disk, Min. 512 Ram. Dvd Writer, 17 Inches Lcd / Tft Monitor. 2.Should Have Compatible Color Photo Printer. 4. System Configuration Accessories, Spare And Consumables 1.System As Specified. 5. Environmental Factors 1.The Unit Shall Be Capable Of Being Stored Continuously In Ambient Temperature Of 0-50 Deg C And Relative Humidity Of 15-90% 2.The Unit Shall Be Capable Of Operating Continuously In A Ambient Temperature Of 10-40 Deg C And Relative Humidity Of 15-90%. 6. Power Supply 1. Power Input To Be 220-240Vac, 50Hz Fitted With Indian Plug 2.Suitable Ups With Maintenance Free Batteries For Minimum One-Hour Back-Up Should Be Supplied With The System. 7. Standards, Safety And Training 1.Should Be Fda, Ce, Ul Or Bis Approved Product 2.Manufacturer Should Have Iso Certification For Quality Standards. 3.Electrical Safety Conformsto Standard For Electrical Safety Iec 60601-1 General Requirements ( Or Equivalent Bis Standard ) 8. Documentation 1.User / Technical / Maintenece Manuals To Be Supplied In English. 2.Certificate Of Calibration And Inspection. 3.List Of Important Spare Parts And Accessories With Their Part Number And Costing. 4.Log Book With Instruction For Daily, Weekly, Monthly And Quarterly Maintenance Checklist. The Job Description Of The Hospital Technician And Service Engineer Should Be Clearly Spelt Out. , Rvg With Sensor Size 1 True Image Resolution 14Lp / Mm Or Less Sensor Resolution 27.03 1 / Mm Or Less Usb2 – High Speed Connection Super Cmos / Ccd With Optical Fiber Technology , S / S Suction Cannula Tip 3No. , S / S Suction Cannula Tip 4No , Sand Blasting Machine For Ortho Use ( Microetching, Bracket Recycling , Sand Blasting Unit For Orthodontic Bracket Recycling Portable With Pressure Guage And Starter Kit , Sandblasting Machine , Scanner Scanner System For The Fabrication Of Esthetic & Functional Dental Restorations With Following Features: Should Work On The Principal Of Contact Scanning Should Offer Fabrication Of Crowns, Laminates, Abutments & Bridge For All Indection & Custmise If Need Be. Cad / Cam Software With Easy To Use Tutorials Open Design For Unrestricted Visibility & Access Should Be Able To Detect Undercuts. Should Be Able To Scan And Produce Coping And Bridges In Both Alumina And Zirconia Should Be Able To Scane And Produce Full Mouth Bridge Upto 14 Units. , Schluger Bone File ( Interdental ) , Schlugers Bone File No.9 / 10 , Scissor , Semi Automatic Rotary Microtome Semi Automatic Microtome With Stepper Motor Driven Specimen Feed. Vertical And Horizontal Cross Roller Bearing Mechanism To Ensure Accurate Reproducibility Of Section Thickness. Section Thickness Selection From 0.5 To 100Um. Section Thickness Range : 0.5Um-100Um Increment 0.5Um-5Um In 0.5 Um Increment 5Um -20Um In 1Um Increment 20Um-60Um In 5Um Increment 60Um- 100Um In 10 Um Increment Trimming Thickness Setting From 1Um To 600 Um With Step Rim Function. Programmable Retraction Of 5Um To 100 Um In 5Um. Retraction Can Be Deactivated When Not Required Two Forward And Backward Coarse Feed Speed And Electric Coarse Feed At 300Um / S And 900Um / S. Sectioning Modes: 2 Continuous And Rocking Mode Should Have Rocking Mode Action Of Sectioning To Minimize The Risk Of Developing Repetitive Motion Disorders ( Rmd ) . Horizontal Feed Of 28 Mm Via Stepper Motor And Vertical Stroke Length Of 70Mm Visual And Acoustic Remaining Feed Indication Specimen Orientation Of 8 Degree Both Horizontally And Vertically Section Counter And Section Thickness Totalizer All Controls On The Instruments With External Control Unit Disposable Blade Holder With Lateral Displacement One Hand Operated Universal Cassette Clamp And Magnetized Section Waste Tray. , Sialandoscope , Sialography Cannula , Sickle Explorer 17 / 23 ( Hu Friedy / Medsey / Equinox ) , Smith Spreader , Soft Tissue Diode Laserspecification; 810 To 980 Nm Wavelength Wattage 7 - 10 Watt Continuous Wave, With Fiberoptic Tips , Specifications Of High Speed Refrigerated Centrifuge Maximum Speed ( Rpm ) 26, 000 To 29, 000•Maximum Rcf ( X G ) 70, 000 To 100, 000 •Maximum Capacity ( Tubes X Ml ) 6 X 1000 In Swing Bucket Or Fixed Angle .•Drive Motor: High-Torque Brushless High-Frequency Motor •Imbalance Tolerant Drive•Temperature Range Must Be ( °C ) : –10 To +40 •Controls: Microprocessor Based, Touch-Screen Interface ( Can Be Used With Gloved Hand ) . Memorybased Programmed Operation 30 Programmed Operations Possible. •Acceleration / Deceleration Profile: Nine Stage Variable Acceleration. Nine Stage Braked Deceleration, • Plus Free Decelerationrefrigeration System : Cfc / Hcfc Free With 5-Year Non-Prorated Warranty•Run Time : 99Hrs; Hold•Programmability : 30 Programs Or More•Actual Run Timer•Temp. Control Accuracy : ± 2°C Of Set Temperature •Speed Control Accuracy : ± 20 Rpm•S Peed Control Range : 100 To 26, 000 Rpm Or 500 To 29, 000Rpm •Machine Should Be Compatible With Continuous Flow Operation ( For Future Upgradation ) •Rcf Calculation Rcf Integrator, Rtc ( Real Time Control ) , Over Speed Detector Facility •Automatic Rotor Lock / Self-Locking System •Automatic Rotor Identification System •Ambient Temperature For Operation: 2°C To 40 °C •Non Contact Imbalance Protection•Pre Cooling Chamber•Power : 200-240 Vac, 50 Hz, 30 A, Single Phase •Mandatory 2 Rotors To Be Quoted With The Specifications Mentioned Below. •Should Be Supplied With Suitable 10Kva Servo Voltage Stabilizer. •Warranty: Comprehensive 5 Years On Both Machine And Rotor From The Date Of Installation Directly• Certified By The Manufacturers.In Addition During The Entire Warranty Period 2 Maintenance Service Visits By Engineers Is A Must.•Company Should Provide User List With Email And Phone Numbers Of Orders Placed In The Last 2Years. . The Centrifuge Must Have An Energy Savings Mode ( “Sleep Mode” ) To Reduce Power Consumption Up To 15% By Turning Itself Off If Idle After A Period Of Time. The Centrifuge Must Be Able To Satisfy Culus And Ce Safety Requirements Without Being Bolted To The Floor, To Provide Flexibility To Relocate Within The Facility. Required Rotors: 1. Fixed Angle Rotor 8X50ml Rpm 25, 000 And Above And Rcf 75, 000 X G Or Above With Polyallomer 50Ml Tubes And Adapter For 10 Ml Along With Tubes ( Minimum 50 Tubes Of Each Volume Should Be Quoted In Main Offer ) 2. Swing Bucket Rotor 4X500ml Rpm 5, 300 Or Above And Rcf 6, 800 X G Or Above With Adapters For 50Ml Conical Tubes, 15Ml Conical Tubes And Mtp’S Carrier. Optional Rotor: 1. Fixed Angle Rotor 6X1000ml Rpm 8, 000 And Above And Rcf 15, 900Xg And Above Should Be Quoted Along With Pc Bottles. All Rotors Should Be Quoted In Main Offer Along With The Centrifuge , Spindle Grinder , Spinix-Vortex Shaker Compact, Rugged Construction Heavy Metal Base And Rubber Feet Prevent Movements Of The Shaker During Use Choice Of Continuous And Touch Mode Variable Speed Control Maximum Speed 3000 Rpm Spare Cup Attachment Spare One Hand Attachment Spare One Hand Insert Spare Micro Tube Insert , Split Cast System , Spong Holding Forceps , Spoon Escavator , Sprit Lamp , Ss Tray Dentulous Kit Set , Ss Tray Edentulous Non Perforated , Stereo Zoom Microscope Specifications Preferable Make: Olympus, Zeiss Or Leica Optical Bodytrinocular Body Zoom Ratio1:7 Objective Zoom Range0.65 X – 4.5 X Eye Pieceswf 10X / 22Mm ( High Eye Point Super Widefield Eyepieces ) Working Distance100 Mm Interupillary Distance Adjustment55 Mm -75 Mm Binocular Head Inclination Of45 Deg Diopter Adjustment+ / - 5 Diopter Optical Body Rotation360 Deg Reflected And Transmitted Illumination Volt Input 220V / 50 Hz Top Halogen Lamp 6V 15 V Adjustment Brightness Bottom Fluroscent Lamp 5 W , Sterilization Package B Class, 50 Liter Steam Sterilizer With Vacuum Dry System Printer. • Perfect Sterilizer With Vacuum Dry System With Lcd Display • Lamp Light Will Be On When The Door Is Closed • Lamp Light Will Be On When The Heater Is Heating Process • When Sterilizing Process Start, Sterilization Display Lamp Light Will Be On • Dry Lamp Will Be On When Drying Process Is Started • During Each Processuser Can Choose To Pass Any One Process By Pressing The Pass Button • Control Panel : Device To Manipulate& Control The Sterilization Process Technical Specification: Rated Voltage And Frequency :Ac 220V / 50 / 60 Hz Power Consumption : 2.9 Kw Capacity Of The Chamber: 50L Sterilizing Pressure : 1.0 Kg / Cm2and 2.0 Kg / Cm2 ( + 20% ) Sterilization Temperature: 1210 C + 40 C And 1320+50 C Protection Type & Degree For Electronic Shock B ) Washerdisinfector. • The Universal Large-Capacity Solution • Three Face Connection For Short Programme Durations • Can Take Upto 11 Transmission Instruments Per Load • Efficient Cleaning And Disinfection In A Single Closed System • Interface For Process Documentation • Thermal Disinfection System • Can Be Connected To Liquid Dispensing Systems. • Front Loader With Drop-Down Door Without Baskets • Freestanding Appliance With Lid Can Be Built Under In A Run Of Units • Fresh Water System , Max Temperature 930C • Electrical Door Lock • Buzzer To Signal End Of Programme • Programme Failure Check • Serial Interface For Process Documentation C ) Pouch Sealer Sealer For 75 & 100 Mm Size Pouch Rolls Are Mounted Together Above The Sealer Thermostatic Contol Perfect Seal Easy To Handle Minimum Space D.Table Top Distil Water Plant Water Purifier Should Beequipped With An Automatic Control Thermostat With Blocksystem To Besupplied With: No. 1 Detergent No. 1 Container For The Distilled Water Variousaccessories. E ) Handpiece Cleaner • Safe For Anybody To Use • Automatically Purges Excess Solution From Handpieces • Automatically Removes Solution Vapour From The Chamber • Economical, Efficient And Time Saving • Extends The Life Of Handpieces • Compact Size And Easily Installed • Professional Handpiece Maintenanceand Lubrication System • Maintains All Handpiece Brands • A Fail Safe Maintenance Solution For All Dental Handpieces F ) Needle Burner / Destroyer: With Automatic Syringe Cutter , Sterlizer Boiler A. Small B. Medium C. Large , Straight Explorer , Straight Probe Williamsprobe , Sub Gingival Scaler , Suction Machine Vacuum Suction Devices, Noise Level:65Db, Small Size, Light Weight, Silent And Easy To Install, Dental Suction With Liquid Drainage Pump, Mainly Used In Hospitals Of All Levels For Suction Of Blood , Sugerman Bone File 1S / 2S, 3S / 4S ( Hu-Friedy / Medsey / Equinox ) , Supra Gingival Scalers Set ( U 15 / 30Posterior Jacquet, Cumine , Sickle Scalers ) , Surgical Loupe4x 4X Zoom, Working Distance 18 Inches ( 450 Mm ) With Titanium Frame , Surgical Micromotor Fiber Optic Having 200-40, 000 Rpm, High Torque With Foot Control, Low Noise And Vibration Free Autoclavable Micromotor . Advanced Torque Calibration To Automatically Set Optimum Speed And Torque For Each Individualattachment With High Level Accuracy. Cellular Optic Light Emission From The Handpiece Provides Clear Illumination Of The Target Site To Facilitate Even Faster More Precise Treatment. Supplied With 20 Degree Angle Hp Straight Handpice Autoclavable 40, 000 Rpm 20: 1 Reduction Handpiece For Implant , Surgical Scissors , Surgical Trolly , Surveying Unit , Suture Cutting Scissors , Suture Needle Holder , Table Top Distil Water Plant With Accessories • Water Purifier Should Beequipped With An Automatic Control Thermostat Withblocksystem. To Besupplied With: • No. 1 Detergent • No. 1 Container For The Distilled Water , Three Prong Plier , Tissue Guard 40+A550-331, 4108-830 Messal ( O.Or. ) , Toffle Mere Retainer , Torquing Keys One Torquing Plier And Keys Of 0.018 And 0.022 , Torquing Turret Rectangular Arch Forming Turret. Slots Marked Indicating Wire Gauge .016 X .022, .017 X .025, .0215 X .028, .019X.025, .0215X.028. , Toungue Blade , Towel Clips5” , T-Scan Occlusal Analysis System , Twizzer , U / L Edentulous Die Metallic ( Brass ) , Ultra Bone Surgery Unit ( Piezosurgery ) Piezosurgery Unit With Automatic Feedback System For Power Control, Handpiece Interference Indicator, Working Frequency For 24-29.5 Khz, Ce / Isi Aproved , Ultra Sonic Instrument Washer Maximum 2 Liter Capacity With Waqrning Function B Type , Ultra Sonic Instruments Washer ( 13 Lt ) , Ultra Sonic Scalersunit Specification; Piezotronic Scaler28 To32 Khz Frequency. Autoclavable Handpiece Total Control Is Micro Processed Based Control Unit.Sleek Handpieces. The Scaler Is Supplied Withminimum3 Tips , Ultra Sonic Scalers Inserts ( Compatible With Satellac Scalers ) Insert Number – N1, N10x, N3 , Ultrasonic Cleaner Minimum Capacity 13 Liters With Mesh Bucket , Ultrasonic Cleaner Minimum Capacity 5 Litre , Ultrasonic Cleaner Programmable With Time Adjustment & Spare Tray , Ultrasonic Cleaner For Cleaning Casting ( Small ) , Ultrasonic Crown Remover For Removing Crowns& Bridges , Ultrasonic Retro-Preparation, Endodontic And Conservative Inserts , Ultrasonic Scaler Hand Piece ( Woodpaker ) , Ultrasonography Machine , Universalplier , Uv Chamber S.S. Chamber With 12 Die Pressed Ss Trays Imported Uv Tube Mounted On S.S. Reflector Emits Uv Light ( Germicidal In Properties ) , Technical Specifications: Uv Tube: 15W Chamber Size:23” X 13” X 8” Weight: 12.0 Kg. No. Of Trays : 12 ( 9 Shallow + 3 Deep ) Door Closing Mechanism:Magnetic Gasket , Uv Vis D / B Spectrophotometer Optical Design: Double Beam With Sample And Reference Cuvette Positions; Czerny-Turner Monochromator Spectral Bandwidth: 1 Nm Light Source: Xenon Flash Lamp, 3-Year Warranty Detector: Dual Silicon Photodiodes Scan Ordinate Modes: Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, Log ( 1 / R ) , Log ( Abs ) , Abs*Factor, Intensity Resolution: >1.6 ( Peak-To-Valley Ratio ) Wavelength Range: 190 –1100 Nm Wavelength Accuracy: ± 0.8 Nm ( Full Range ) ± 0.5 Nm ( 546.11 Nm Mercury Line ) Wavelength Reproducibility: Less Than 0.1 Nm ( 546.11 Nm Mercury Line, Sd Of 10 Measurements ) Scanning Speed: <1 To 6000 Nm / Min; Continuously Variable Slew Speed: 31, 00 Nm / Min Data Intervals: 10, 5, 2, 1, 0.5, 0.2, 0.1 Nm Photometric Range: > 3.5 Abs Photometric Accuracy: 0.5 A: ± 0.004A;1A: ± 0.006A; 2A: ± 0.010A; ( 440 Nm; Traceableneutral Density Filters ) Noise: 0A: Less Than 0.00015 A; 1A: Less Than 0.00050 A; 2A:Less Than 0.00080 A; ( 260 Nm, Rms ) Drift: < 0.0005 A / Hr ( 500 Nm, 1 Hour Warm-Up ) Stray Light: Kcl, 198 Nm: Less Than 1% T Nai, 220 Nm: Less Than0.05% Tnano2, 340 Nm, : Less Than 0.05% T Baseline Flatness: ±0.0010 A ( 200-800 Nm; Smoothing ) Keypad: Sealed Membrane Local Control Display: Touch Screen Lcd Panel; 800 X 480; 17.8 Cm ( 7 In ) Diagonal With In-Built 300Gb Memory Capacity. Operating System: Microsoft Windows Xp Embedded Dimensions: 62.2 X 48.6 X 27.9 Cm ( 24 X 19 X 11 In ) L X W X H Weight: 14.4 Kg ( 32 Lb ) Electrical Supply: 100 – 240 V, 50 – 60 Hz, Selected Automatically; 150 W Maximum Next-Generation Uv-Vis Instrument With The Latest Technology To Bring You The Usability And Performance You Demand Without Added Complexity Features: ~ Up To 100 Hz Data Acquisition For Single Cell Kinetics ~ Complete Line Of Peltier Temperature Control Accessories ~ Adjustable Cell Holder For Optimum Cell Positioning ~ Numerous Accessories For Liquid And Solid Sampling ~ Performance Verification And Optional Software And Documentation For Regulated Laboratories -User Friendly S / W To Do Various Orders Of Spectral Derivative Analysis. Insight Software Features: ~ Advanced Fixed Wavelength Analysis With Graphical Data Display And User Defined Limits ~ Wavelength Scanning Application With Advanced Tools For Peak Analysis And Spectral Processing ~ Next-Generation Quantification Package Makes Quantitative Analysis Straightforward ~ Integrated Calculations Provide More Data Per Measurement In Quant ~ Automated File Export And E-Mail ~ Seamless Paper-Based Reporting With User Defined Parameters ~ Workbook And Template Scheme Makes Data Organizationeasy ~ Cue Software For Customized User Interface And Workflows Includes: ~ Euro / Us Power Cords ~ Single Position Cell Holder ~ Stylus For Touch Screen Interaction ~ Insight Software For Computer Control Of Instrument And Off- Line Data Analysis ~ Usb Memory Device ~ Power Cord Indian 250V , Vaccum And Pressure Moulding Unit Single Unit Pressure And Vaccum Based With Different Sheet Size Adjustment, Microprocessor Based, Programmable, Starter Kit And Pressure Gauges. , Vaccum Investment Equipment , Vaccum Thermoforming Unit For Entire Range Of Dental Thermoforming ( Kalabhai-Manufacturer- Erkodent, Erkopress By Pressure, Erkoform- Rue By Vaccum ) Twin-Flask With Compressor & Key , Spring Loaded All In Gun Metal-Hanau Type , Vacuum Cleaner , Vacuum Mixer , V-Bend Forming Plier , Vernier Calipers , Vertical Reciprocating Endodontic Handpiece Endo Hand Piece With Capability Of Attaching Both Latch Type And Hand Endodontic Files. Capable Of Working With E-Type Motor. , Vibrator For Eliminating Air Bubbles While Pouring Impressions, Casting Ring Investments And Duplicating Molds. To Provide A Range In Vibration, From Low To Maximum Intensity. Easy In Operation And Maintenance. Featuring -Large Suction Feet For Stability And A Convenient Power Indicator Light To Show When The Vibrator Is On. • Variable Speed Control Knob. Non-Slip Table Top , Vita 3-D Master Shade Guide , Vita Easyshade ( Spectro Meter ) , W H O Probe , Water Distiller Capacity 6 Ltr. , Water Heater 10 Litt. Capacity , Water Retractive Valve , Water Spray Valve , Wax Carver , Wax Dipping Pots × Electronic Controlled Wax Pots × Four Individual Square Containers × Uniform Temperature Maintenance × Physical Characteristics Of Wax Unaltered × 30`C- 110`C , Wax Elimination Furnace , Wax Knife , Wax Spatula , Weingardt Plier With Tungsten Carbide Tip , Whipmix Arcon Articulator With Face Bow For Direct & Indirect Mounting , William’S Periodontal Probe , Winter’S Cross Bar Elevator , Wire Cutter ( Double Action ) , Wire Cutter For Maxillofacial Use , Wire Tucker , Wire Twister6” , X-Ray Clip , X-Ray Film, Holder Snap A Ray , X-Ray Hanger , X-Ray View Box Led X-Ray View Box , Powder Coated Ms Cabinetwith Aluminium Frame 14 Inches X 17 Inches , Mouth Prop Open And Close Serrated , Metal Suction Tip , Caries Removal Hand Instrument Smart Kit , Bite Block , Micromotor Hand Piece Contra Angle Push Button , Electrical Wax Carver ( With 2 Tips ) , 5 Axis Cad-Cam With Hilling Machine , Flexible Denture Injection System , Injection Molding System , Orthodontic Software For Cephalomatric With Image Manipulation Software And Surgical Prediction For Cbct Images , Slr Camera :- Digital Slr Camera For Intra Oral Use -Digital Slr Set W / Body Cap, Lcd Monitor Cover, Neck Strap, En-El3a Rechargeable Battery, Mh-18A Quick Charger W / Power Wire, Usb Cable, Video Cable, Software Cd Rom, Rechargeable Battery , 18-70 Mm F3.5-4.5 G Afs Dx If –Ed Zoom Lens , Scandisk 1Gb Compact Flash ( Cf ) Memory Card, Additional Macro-Lens And Filter, Auto Zoom Flash Compatible With Camera, Ring Flash Compatible With Slr Camera, Light- Kit And Backdrops For The Studio , Spinix-Vortex Shaker Compact, Rugged Construction Heavy Metal Base And Rubber Feet Prevent Movements Of The Shaker During Use Choice Of Continuous And Touch Mode Variable Speed Control Maximum Speed 3000 Rpm Spare Cup Attachment Spare One Hand Attachment Spare One Hand Insert Spare Micro Tube Insert , Oralcdx - Oral Brush Biopsy - Painless Oral Brush Biopsy In Minutes. Simply Mail The Slide & Test Forms In The Prepaid Mailer To Cdx Lab Where Specially-Trained Pathologists Analyze With Assistance Of Advanced Computer Analysis. Each Oralcdx Biopsy Test Includes A Sealed, Sterile Biopsy Brush, Two Fixative Packages, A Glass Slide And Slide Holder, A Prepaid Mailer Box, A Test Requisition Form, Billing And Reimbursement Information. Ada Accepted. Includes 12 Complete Biopsy Tests And Instructions. Manufacturer Code: 12Pk Brand: Oralcdx Component ( S ) : Complete Mail In Kit Packaging: Package Of 12 Complete Biopsy Kits , Advanced Research Microscope With Attachments Infinity Color Corrected Optical System Per Focal And Per Centric Inverted Image, 30° Inclined Sidentoff Trinocular Head, Interpupillary Distance: 50Mm~76Mm; Splitting Ratio R:T=100:0 Or 20:80 Or 0:100 High Eye Point Wide Field Plan Eyepiece Pl10x25mm, With Reticule, Eye Guard, Diopter Adjustable Nosepiece ( With Dic Slot ) , Septupletnosepiece ( For 7 Nosepiece ) , And Rubber Eyecups ( Pair ) . Polarizer And Analyzer Biological Frame ( Transmitted ) , Low-Position Coaxial Coarse And Fine Adjustment, Coarse Adjustment Distance: 25Mm; Fine Precision: 0.001Mm. With Coarse Adjustment Stop And Tightness Adjustment. Built-In 100-240V_Ac50 / 60Hz Wide Voltage Transformer, Intensity Adjustable By Digital Set And Reset Led;Built-In Transmitted Filters Lbd / Nd6 / Nd25 ) Stage: Mechanical Stage, Moving Range: 75Mm X50mm; Precision: 0.1Mm; Two-Way Linear Drive, Tension Adjustable , Stage Micrometer, Double Slide Holderslot For Polarizer And Analyzer Plan Achromatic 4X / 0.13, Phase10x / 0.40, Phase20x / 0.75Plan Flour 40X / 0.95, Phase 40X, Plan Fluor100x, / 1.30 Phase 100X. Adjustment: Integrated All-Metal High-Pressure Die-Castingbody, Precision Transmission Mechanism With Pinion And Rack. Coarse Focusing Scope Universal Condenser Forphase , Dark Field And Bright Field. Transmitted Illumination: 12V 100W Halogen Lamp Intensity Continuously Adjustable, 100V-240V_Ac50 / 60Hz Wide Range Voltage, Lbd Color-Change Filter ( F45mm ) , Immersion Oil-8 Ml, Allen Hex Keys- F2mm Vinyl Dust Cover, Universal Power Supply 05 Unit 12V / 100 W Spare Bulb. Epi – Fluorescence Attachment With Sextuple Reflected Fluorescence Illuminator With Iris Field Diaphragm And Aperture Diaphragm, Central Adjustable; With Filter Slot And Polarizing Slot; With Fluorescence Filters, Uv, Fitc, Tritc Fluorescence Filter. Advance Cooled Camera For Fl, Bf, Df And Phase Imaging. Color: Colorcooled Two-Stage Te-Cooling With Controllable Electric Fan Spectral Range: 380-650Nm ( With Ir-Filter ) Resolution: 9 Micron ×9 Micron, Fps:30 Data Interface: Usb3.0 / Fire Wire Interface Ensuring High Speed Data Transmission; Exposure Time: 0.1Ms~3600S, Recording System: Still Picture And Movie Advance Imaging Software For Measurement, Multilayer Focus, Stitching, Time Laps Imaging Etc. Compatible Branded Computer Supply With Above System. Upgradable To Fully Motorize At Any Point Of Time. , Microwave For Ihc , Cryostat Technical Specifications Microtome Section Thickness Selection 1 - 100 ?M Total Specimen Feed 25 Mm Vertical Specimen Stroke 59 Mm Maximum Specimen Size 55 X 55 Mm Or 50 X 80 Mm Specimen Orientation 8° ( X, Y, Z-Axis ) Electric Coarse Feed, Slow 600 ?M / S Electric Coarse Feed, Rapid 900 ?M / S Refrigeration System 50 Hz / 60 Hz Cryochamber Temperature Setting Range 0°C To -35°C ( +3 K / -3 K ) Cooling Time Down To -35 °C Max. 6 Hours, At 22°C Ambient Temperature Defrost Automatic Hot Gas Defrost, 1 Automatic Defrost Cycle / 24 Hours, Time-Controlled ( Duration 12 Min. ) Quick-Freeze Shelf Maximum Cooling -40°C ( +3 K / -5 K ) Number Of Freezing Stations 8 Defrost Manual Hot Gas Defrost, Time-Controlled ( Duration 12 Min. ) Peltier Element Max. Temperature Difference 17K, At -35°C Chamber Temperature Number Of Freezing Stations 2 Defrost In Conjunction With The Quick-Freeze Shelf Dimensions And Weights Width ( W / O Handwheel ) 600 Mm / 23.6 In Width ( With Handwheel ) 730 Mm / 28.7 In Depth 730 Mm / 28.7 In Height 1140 Mm / 44.8 In Weight ( Incl. Microtome, Without Specimen Cooling ) Approx. 135 Kg / 298 Lbs Uvc Surface Disinfection 30 Or 180 Minutes, User Selectable Technical Specifications Subject To Change Without Prior Notice , Hard Tissue Microtome Section Thickness Range: 0 - 1, 000 ?M, Adjustable In 1-?M Steps Total Horizontal Specimen Stroke: Maximum 275 Mm Total Vertical Knife Feed: 70 Mm Knife Retraction ( During Specimen Return Stroke ) : 0 - 1, 000 ?M Clearance Angle Adjustment: 0° - 17° Knife Declination - Fixed Setting ( Declination Blocks = Optional Accessory ) : 45° Maximum Specimen Size ( L X W X H ) : 250 X 200 X 70 Mm Specimen Orientation ( Along X / Y Axis ) : 4.8° Along Each Axis Specimen Orientation ( Rotation ) : Approx. + / - 3 And 90° Sectioning Speed: 0.5 - 100 Mm / S, Adjustable In 0.1 Mm Steps Return Speed: 0.5 - 100 Mm / S, Adjustable In 0.1 Mm Steps Manual Knife Movement ( Slow / Fast ) : 37 Mm / S And 74 Mm / S Manual Specimen Movement ( Slow / Fast ) : 37 Mm / S And 74 Mm / S Electrical Connections: Nominal Voltage: 100 / 120 / 230 / 240 V Nominal Frequenzy: 50 Hz And 60 Hz Maximum Power Draw: 1, 400 Va Main Fuses, Type Mda, Fa. Bussmann: 2 X T10a Protective Class: I Overvoltage Installation Category: Ii Vacuum Cleaner: 100 / 120 V - Maximum Power Draw 500 Va Vacuum Cleaner: 230 / 240 V - Maximum Power Draw 1, 200 Va Lamp: 100 / 120 V - Maximum Power Draw 100 W Lamp: 230 / 240 V - Maximum Power Draw 200 W Dimensions And Weights: Microtome ( H X W X L ) : 250 X 390 X 750 Mm Control Unit ( H X W X D ) : 220 X 385 X 510 Mm Required Bench Top Space For Microtome And Control Unit:1, 000 X 950 Mm Microtome: Approx. 75 Kg Control Unit: Approx. 23 Kg , Tissue Storing Cabinet ( Frozen ) , Image Analysis Software Image Pro Express , Spinix-Vortex Shaker Compact, Rugged Construction Heavy Metal Base And Rubber Feet Prevent Movements Of The Shaker During Use Choice Of Continuous And Touch Mode Variable Speed Control Maximum Speed 3000 Rpm Spare Cup Attachment Spare One Hand Attachment Spare One Hand Insert Spare Micro Tube Insert , Digital Magnetic Hot Plate Stirrer Digital Magnetic Hot Plate Stirrer : 25K Type Of Product:Digital Magnetic Hot Plate Stirrer Max. Stirring Quantity ( Water ) ( Liters ) :3 Ltr Voltage:100-120V Ac / 200-240V Ac Dimension Of Top Plate ( Mm ) :5 Inch Motor Rating Input / Output ( W ) :5W / 3 W Speed Range ( Rpm ) :100 - 1500 Rpm Speed / Temperature Display:Led Top Plate Material:Stainless Steel With Ceramic Coated Hotplate Heating Power ( W ) :500 W Temperature Range:5-40°C Dimensions ( Wxdxh ) ( Mm ) :150X260x80 Mm Frequency:50 / 60 Hz Control Accuracy Of Heating Temperature With Pt-1000:±0.5 External Temperature Sensor:Pt-1000 Weight ( Kg ) :1.8 Kg Protection Class Acc. To Din En60529:Ip21 Power:515 W , High Speed Refrigerated Centrifuge Maximum Speed ( Rpm ) 26, 000 To 29, 000•Maximum Rcf ( X G ) 70, 000 To 100, 000 •Maximum Capacity ( Tubes X Ml ) 6 X 1000 In Swing Bucket Or Fixed Angle .•Drive Motor: High-Torque Brushless High-Frequency Motor •Imbalance Tolerant Drive•Temperature Range Must Be ( °C ) : –10 To +40 •Controls: Microprocessor Based, Touch-Screen Interface ( Can Be Used With Gloved Hand ) . Memorybased Programmed Operation 30 Programmed Operations Possible. •Acceleration / Deceleration Profile: Nine Stage Variable Acceleration. Nine Stage Braked Deceleration, • Plus Free Decelerationrefrigeration System : Cfc / Hcfc Free With 5-Year Non-Prorated Warranty•Run Time : 99Hrs; Hold•Programmability : 30 Programs Or More•Actual Run Timer•Temp. Control Accuracy : ± 2°C Of Set Temperature •Speed Control Accuracy : ± 20 Rpm•S Peed Control Range : 100 To 26, 000 Rpm Or 500 To 29, 000Rpm •Machine Should Be Compatible With Continuous Flow Operation ( For Future Upgradation ) •Rcf Calculation Rcf Integrator, Rtc ( Real Time Control ) , Over Speed Detector Facility •Automatic Rotor Lock / Self-Locking System •Automatic Rotor Identification System •Ambient Temperature For Operation: 2°C To 40 °C •Non Contact Imbalance Protection•Pre Cooling Chamber•Power : 200-240 Vac, 50 Hz, 30 A, Single Phase •Mandatory 2 Rotors To Be Quoted With The Specifications Mentioned Below. •Should Be Supplied With Suitable 10Kva Servo Voltage Stabilizer. •Warranty: Comprehensive 5 Years On Both Machine And Rotor From The Date Of Installation Directly• Certified By The Manufacturers.In Addition During The Entire Warranty Period 2 Maintenance Service Visits By Engineers Is A Must.•Company Should Provide User List With Email And Phone Numbers Of Orders Placed In The Last 2Years. . The Centrifuge Must Have An Energy Savings Mode ( “Sleep Mode” ) To Reduce Power Consumption Up To 15% By Turning Itself Off If Idle After A Period Of Time. The Centrifuge Must Be Able To Satisfy Culus And Ce Safety Requirements Without Being Bolted To The Floor, To Provide Flexibility To Relocate Within The Facility. Required Rotors: 1. Fixed Angle Rotor 8X50ml Rpm 25, 000 And Above And Rcf 75, 000 X G Or Above With Polyallomer 50Ml Tubes And Adapter For 10 Ml Along With Tubes ( Minimum 50 Tubes Of Each Volume Should Be Quoted In Main Offer ) 2. Swing Bucket Rotor 4X500ml Rpm 5, 300 Or Above And Rcf 6, 800 X G Or Above With Adapters For 50Ml Conical Tubes, 15Ml Conical Tubes And Mtp’S Carrier. Optional Rotor: 1. Fixed Angle Rotor 6X1000ml Rpm 8, 000 And Above And Rcf 15, 900Xg And Above Should Be Quoted Along With Pc Bottles. All Rotors Should Be Quoted In Main Offer Along With The Centrifuge , Microbiology Culture Cabinets With Digital Controlled Temperature And Humidity And Auto Controlled Timer To Start And Stop The Process , Wax Dipping Pots Electronic Controlled Wax Pots Four Individual Square Containers Uniform Temperature Maintenance Physical Characteristics Of Wax Unaltered 30`C- 110`C , Advance Digital Microscope With Imaging Software. Optical System- Infinity Color Corrected Optical System Observation Tube:Seidentopf Digital Viewing Head, 3.2 Million Pixels High Resolution Camera System: Resolution Ratio 2048*1536 Pixels, Line By Line Scan Eyepiece: High Eye Point Wide Field Plan Eyepiece Pl10x / 20Mm, With ±5 Degrees Diopter Control, Ipd: 50-75Mm Objective:Plan Achromatic Objective 4X Plan Achromatic Objective 10X Plan Achromatic Objective 40X Spring Plan Achromatic Objective 100X S, Oil Nosepiece:Backward Quadruple Nosepiece Illumination- Main Supply 100V-240V, 3 Watt Led Lamp Or 6V / 20W Halogen With Intensity Control ( Fixed Center ) Focusing Adjustment:Coaxial Coarse And Fine Focusing Adjustment, With Limited And Tension Adjustment Coarse Adjustment Range: 25Mm, Fine Adjustment Precision:0.002Mm. Condenser: N.A.1.25 Condenser ( With Socket For Phase Contrast And Dark Field Sliders ) Stage:Coaxial Mechanical Stage 140X132mm Size And 76×50Mm Travel Range. Inbuilt Microscopic Scientific Digital Camera With Imaging Software Consisting Of: High Resolution Digital Camera With 1 / 2” Cmos Chip Usb 2.0 Pc Connection Real Time Live Image Resolution: 3 Mega Pixels Electronic Shutter Exposure Time: 1Ms-0.3S Working Temperature: -20°C ~ 70°C Image Analysis Software: Sportily Calibration Line Measurements For Distance, Length, Width, Perimeter, Angle, Three Point Radius. Area By Enclosed Line Controlled By Four Arrow Keys Available On The Keyboard Arrow With Zoomed Preview The Line Measurement Is Not Affected On Zoomed Images. Identification Of Objects In An Image, Count Them, Obtain Several Features Measurements. Objects Identification By User Or Automatically. User Defined Classification On Basis Of Size Or Intensity. Manual, Auto Bright And Auto Dark Methods To Identify Intensity Range Defined Object To Be Measured. Various Calculation & Measurements Available For Selected Particle Are; Dimensions, Area, Perimeter, Ferrite Length, Min / Max Radius, Thread Length, Thread Width, Fiber Length, Fiber Width. Roundness, Shape, Orientation, Elongation, Equal Circular Diameter, Equal Sphere Volume, Data Export Report Generating And Print Out Interactive File Format. , Multichannel ( 8- Channel And 12- Channel Micropipette • Theinstrument Is Fully Autoclavable At 121 Degree And 15 Psi For Duration Of 10-15 Minutes. • Recommended For Elisa ( Diagnostic Test ) , Molecular Screening, Kinetic Studiers, Dna Amplification. • Adjust Volume Easily With Plunger ? The Plunger Has Been Carefully Designed With A High Quality Spring Mechanism To Ensure Sang Free And Soft Movement. ? Simply Turn It To Adjust The Instrument’S Volume Comfortably. • Use Various Tips A With Universal Tipcone ? A Universal Tipcone Enhances The Compatibility Of The Instrument Enables It To Easily Work With Most Internationally Accepted Standard Tips. • Set The Volume With Perfection ? A Soft Click Sound At Every Increment Ensures Perfect Volume Setting And Prevents Any Accidental Changes. It Also Facilitates Single Handed Operation. • Work With A Good Tip ? A Specially Designed Grippyprovides Good Grip And Great Ease Of Use While Operating • Store Safely With A Holder ? The Instrument Includes A Holder That Enables Easy, Efficient And Safe Storage. • Eject Tips With A Sequential Tip Ejector ? A Specially Designed Sequential Tip Ejector And Tip Ejection Knob Facilitates Easy And Effortless Tip Ejection, Single Handedly. • Operate Flexibly ? The Lower Housing Unit Of Both The Instruments Can Be Rotated To 360 Degree, Providing Enhanced Operational Flexibility. • Both 8-Channel And 12- Channel Micropipettes Are Offered In 6 Models, Covering Volume Ranges From 0.5- 10 Microliter To 40- 300 Microliter , Fixed Volume Micro Pipette 1Mu , Fixed Volume Micro Pipette 2Mu , Fixed Volume Micro Pipette 5Mu , Fixed Volume Micro Pipette 10Mu , Pentahead Microscope Optical System Treatment, Uniformly Centered Body Based On Ball Bearing And Wire Guide Thereby Ensuring Smooth And Precise Movement Viewing Head Of Main Observer Setting – 1 No: Viewing Head For Co- Observers Setting – 4 Nos. Setting – 1 Nos. Penta Head Attachments Stand For Support- Two Nos Led Pointer Attachment 1Nos The Co-Observer Get The Same Orientation Of Image As That Of Main Observer Dual Head Attachment Stand For Support – One No Led Pointer Attachment 1Nos Connecting Fitting – 1No Image As That Of Main Observation Eyepiece Wh10x / 20 ( Fn20 ) – 5 Pairs Wh10x / 20 ( Fn20 ) – 2 Pairs Nosepiece Click Stop Objective 10X, 40X ( Spring ) , 100X ( Spring, Oil ) Focus System Slides Mechanical Stage Illumination System, Led 3W ( Lifetime : 30000 Working Hours ) Illumination Condenser ( Na 1.25 ) Focusable With Rack And Pinion , Opg With Ceph Technical Specifications Valid Aerb Type Approval Certificate The Unit Should Have Ccd / Cmos Sensor For 2D Pan & @D Ceph And Should Be Able To Capture Following Programs: Adult & Child Panoramic Bitewing Half Pan Ap & Lateral Sinus Pa & Lateral Tmj Lateral Ceph Ap-Pa Ceph The Unit Should Be Floor & Wall Mounted For Stability. Should Cater To All Patients Including Adult, Pediatrics, Standing, Sitting And Wheel Chair Patients. Should Be Based On Dc Current. Focal Pot Is 0.2 / 0.5Mm Sq Inherent Filtration: 2.5Mm Ai Equivalent. Tube Voltage Min Range 60Kv To 80 Kv Or More Tube Current Min Range 2Ma To 15 Ma Or Higher Exposure Time- Panoramic -1-18 Secs. Pixel Size -100? Or Less. Image Resolution -5-7 Ip / Mm Standard Intel I7 Or Latest Desktop With Original Windows 10 / 64 Bit Software, 4 Gb Ram, 1Tb Hard Disk, 24 Inch Tft Monitor, Dvd-Rw Should Be Supplied With Single Online Tray Dicom Printer With 300 Or More Dpi Able To Print 8’X10’ & 10’X12’ Film Vendor Should Also Supply 01 Packet ( 100 Or More ) Films Of 10’X12’ Films X-Ray Unit Should Be Supplied With Lead Apron, Thyroid Collar And Gonadal Sheath-02 Nos. Should Be Supplied With 2 Customized Tables And 2 Height Adjustable Chairs With Back And Hand Support The Unit Should Be Upgradeable To Cbct In The Near Future, If Required Vendor Should Also Supply 01 No. Suitable Online Ups Min. 3Kva With 10-20 Min Back Up The Vendor Should Have Installed Similar Model Machine To Any Govt. Institute In The Past 3 Years. Enclose Performance Certificate To The Same , Technical Specifications Of Mobile Dental Van To Be Supplied Four Tyre Vehicle With Air Conditioning System Without Seats = 1No. Fuel Type Diesel Tyre 4 No. Max. Power 91 Hp@2800 Rpm Service Brakes Front: Hydraulic Disc, Rear: Hydraulic Drum Max. Torque 250 Nm@1400-2400 Rpm Emission Norms Compliance Bsiv Engine Fm 2.6 Cr Engine Cylinders 4 Engine Displacement 2596 Cc Fuel Tank Capacity 70 Litres Gearbox Synchromesh Transmission 5 Speed Manual ( 5F+1R ) , With 5Th Overdrive Gear Seating Capacity: Without Seats As Dental Chair Has To Be Fitted Overall Length : 6065 Mm Anti-Roll Bar:Front Only Axle Configuration : 4 X 2 Front Axle:Dead Rigid I-Beam, Reverse Elliot Type Front Overhang: 900 Mm Front Suspension: Semi Elliptical Leaf Springs, With Hydraulic Telescopic Shock Absorbers Ground Clearance:210 Mm Gvw: 4060 Kg Overall Height: 2550 Mm, 2770 Mm ( With Ac ) Overall Width: 1975 Mm Rear Axle: Live Rigid Rear Overhang: 1465 Mmrear Suspension: Semi Elliptical Leaf Springs, With Hydraulic Telescopic Shock Absorbers Turning Circle Radius: 6.5 M Tyres: 215 / 75 R 15 Wheelbase: 3700 Mm Air Conditioner: Yes:Split Ac Roof Mounted With Connection For Both Generator As Well As Line Power Supply. Antolock Braking System: Abs With Ebd Driver Seat Type: Standard Seat Mobile Charging Point: Yes Steering Adjustment: Tiltable Steering Type: Power Steering Anti-Roll Bar:Front Only Fog Light:Yes Parking Brakes: Mechanical On Rear Wheels Seat Belts:Yes Battery: 12V, 130 Ah Alternator:2X 110A-Ac Flooring: Button Vinyl Def Tank Capacity ( I ) : 20 Fabrication Work Plumbing Work Fresh Water Tank Made Of Ss-304, Capacity 300 Liters To Be Provided On The Top Of The Vehicle. ( Hand Washing Bay ) : Washbasin Will Also Be Stainless Steel Made. It Has To Be Provided With Looking Mirror Soap Dispenser, Towel Ring Or Hanger. Sink With Elbow Tap. One Wash Basin ( Instrument Washing Bay: One Sink With Elbow Tap, Soap Dispenser, Towel Ring One Grey Water Tank 150 Litters Under Carriage With Outlet Valve Easy To Reach. One Cabinet Below Both The Sinks With Shelves And Door. Plumbing Will Be In Such A Manner That The Same Can Be Easily Repaired In Future Without Any Damage Or Pipes Can Easily Be Change. Exterior And Interior Lighting Illumination Inside The Container Will Be According To Bis / Iso Standard. All Lighting Will Be Led Based. Each Cabin Will Have Minimum Of 02 Emergency Lighting Lamp, Which Will Be Automatically Charged Directly From Line Power Or Generator. Lamps Power To Be Minimum Of 8W. The Total Number, Intensity And Design Of Lights Shall Be Finalized As Per Drawings Electrical Fittings Specifications It Would Include External Power Source ( Shore Power ) And Generator. Specifications For Generator : - 5Kw Generator Fuel Type Petrol: Engine: Eu Or Similar Running Time: Once Tank Is Full Then It Should Work For 10 Hours Alternating Current Supply ( Ac ) And Direct Current Supply ( Dc ) I.E. From Vehicle Battery Or Additional Battery. Cables Used Shall Be Bis Marked ( Legrand & Finolex ) . Copper Conductors To Be Used Will Be With Fire Retardant Pvc Insulation And Will Be Able To Withstand Working Temperature Upto 70 Degree Celcius. External Power Source Will Be In An Accessible And Well Protected Area From Rain Etc. Electrical Cables Will Be Internally Concealed And Located Such That No Part Can Make Contact With Any Fuel Line Or Exhaust System Subjected To Excess Heat. Suitable Special Insulation To Be Provided Where Required Every Electrical Circuit Will Be Provided With Fuse. Electrical Layout Plan To Be Pasted At Visible Location. Adequate Number Of 5 And 15 Amp Plug Points Along With Switches Of Standard Quality ( Bis ) . Location And Number To Be Finalized As Per Design. Main Power Switch / Ups Kva For Equipments Power Source / Line Power Selection Switch. Circuit Breaker Voltage Stabilizer Countertops Specifications Table Countertops Will Be Of Scratch Resistant Material Or Stainless Steel. Edges To Be Covered With Stainless Steel Channel. Table Thickness Will Be Of At Least 25 Mm. The Number, Size And Placement Of Doors And Windows Shall Be Finalized With The Institute Authorities. All Doors / Windows And Hatches Will Comply With Bis Standard Method For Water Proofing Test On Automobiles Doors And Windows Specifications Doors Will Be In Appropriate Dimension Minimum 800 Millimeters ( 2.6 Feet ) In Width And 1900 Millimeters ( 6.23 Feet ) In Height. The Windows Will Be Sliding. Size Of The Window Will Be Minimum 2 Feet Wide And 1.5 Feet High Doors To Have Mechanism To Hold Them In Open Position. Foldable Steps With Anti-Skid Materials To Be Provided. There Will Be Adequate Provision Of Loading Wheelchair On To The Van Cabinet Specifications Table And Cabinet Tops Will Be Of Scratch Resistant Material Or Stainless Steel & Edges Will Be Covered And Smooth. Cabinet And Storage Compartments To Be Made Up Of Powder Coated Steel / Stainless Steel Of At Least 20 Gauges. The Cabinets Will Have Provision For Vision Window, So That The Materials Kept Inside Can Be Seen. Drawers Will Be In Increasing Level From The Top For Easy Of Storage Of Instrument According To Their Sizes. There Will Be A Retractable / Foldable Writing Table In The Passenger As Well As Clinic Area. The Cabinets Etc. Will Be Lockable With Magnetic Self-Locking Latch Type System. The Drawers Will Be Of Medical Grade With Silicone Rollers. The Cabinets In The Clinic Area Will Be Designed In Such A Way That There Is Separate Storage For Dental Instruments, Equipment And Consumables Roof Specifications Made Of Insulated Sandwich Panel As Per Specifications Mentioned Before. Roof To Be Fabricated In A Joint Less Manner To Avoid Rain Water Leakage. External Guttering To Be Provided For Draining Rain Water, Ac Condensation Etc. The Roof Will Be Sturdy Enough To Take A Load Of 100Kg. / Sq. Ft. The Interior Of The Roof Will Be Of Aluminum Composite Panel Of At Least 2 Mm Thickness Floor Specifications Floor Will Be Internally Welded Steel Frame With Formed Steel Cross Members. Flooring Will Be Of At Least 0.6 Mm Thick Gi Sheet Over Which Will Be At Least 18 Mm Thick Fire Retardant, Marine Grade Plywood Will Be Bonded. On The Floor Will Be Pasted A 1.5 Mm Thick Industrial Grade, Durable, Non-Slip, Anti-Static Coated Vinyl Flooring Of Superior Quality. The Entire Flooring Will Be Water Proof Using Adequate Coating And Under Coatings. Floor Will Have Adequate Initial Steel Framework Reinforcements For Mounting Equipment And Other Gadgets And Accessories Securely Interior Body Specification Inner Skin Will Be Of 1.5 Mm Thick Grp / Acp Sheet. The Body Of The Rear Compartment Will Be Made From Minimum 40 Mm, Thick & Monolithic Sandwich Panel For Each Of The Surfaces. An Insulation Of 40 Mm Must Thick Puf ( Poly Urethane Foam ) Must Be Provided. The Density Of The Puf Will Be 40Kg / M3 Minimum. The Interior Wall Will Be Smooth With No Visible Joinery, Made Of Medical Grade Material, Aluminum Composite Panel Of At Least 2 Mm Thickness. The Panel Edges Will Be Covered With Stainless Steel / Aluminum Formed Section. The Use Of Wood Is To Be Avoided. 2 Fire Extinguishers In Driver Cabin And 1 In Operatory With Fixed Brackets. Public Addressing System In Driver Cabin With Overhead Microphone Fixed Dustbin For Bio Medical Waste Exterior Graphic Designing With Logo Of The College And Full Wall Pictures To Be Provided By The Departmentdetails Of Dental Equipments Dental Chair= 2 No Operated Dental Chair With Zero Program With Right Arm Rotatable. Body Contoured, Led Operating Light, Having On And Off And Intensity Control By Non-Touch Sensor With 3 Directional Movements. Chair Side Porcelain Spittoon With Auto Water Connection. High And Low Vacuum Dry Suction, With Drain And Auto Flush. Modular C Delivery Hanging System. Air Rotor Points 02 Nos. Micromotor 35000 Rpm With Digital Display Of Speed. Three Way Syringe 02 Nos., One Operator / One Assistant Scalar ( In Built ) With 5 Scalar Tips. Light Cure Gun. S. Steel Instrument Tray. X-Ray Viewer. Dental Operator Stool And Dental Assistant Stool. Light Cure Gun Specification: Digital Display For Timer, Light Intensity 1000Mw Per Square Centimeters, 04 Smart Modes ( Fast, Pulse, Ramp And Slow ) Accessories With Each Chair 1 Dental Compressor 1 Hp 1 Press Button, High Performance Air Rotor Preferably With Ceramic Ball Bearing Potable Dc X-Ray With Self Developing Films And Portable Rvg With Tablet= 1No.Each Rvg Sensor System:- Rvg- Water Proof Sensor, Should Be Possible To Safely Insert Sensor In Disinfectant, Shock Resistant With Silicon Padding, Shouldbepossibletoseetheimagefastest Processing, Sensor Dimension 25-32X39-45Mm, Active Area On Sensor Approx. 600-900Mm2.Sensor Technology Should Be Cmos, Sensor Cable Length 03 Meters, Resolution In Excess Of 22Lp / Mm. Other Essential Requirement Should Quote Suitable Laptop. Product Must Have Iso / Ce / Usfda Certification. Manufacture Or Supplier Should Have Iso Or Bis Certification. Guarantee For 03 Years Comprehensive. Amc For 05 Years After Expiry Of Guaranty. ( Price Should Be Quoted ) Should Provide Original Brochure ( Printed In English ) Onsite Training. Manufacturer And Supplier Should Furnish A Certificate Stating That The Equipment Is Original Not A Reconditioned One. Autoclave= 1No. 11 Liters, Top Loading And To Be Fixed In The Cabin , Pascal Pressure Cooker For Immunohistochemistry , Thermo Statistically Controlled Wax Dipping Pots With Digital Display Electronic Controlled Wax Pots Four Individual Square Containers Uniform Temperature Maintenance Physical Characteristics Of Wax Unaltered 30`C- 110`C , Paraffin Embedding Wax Bath Thermostatically Controlled Double Walled With Cups And Sleeves For Glass Tubes. Temperature Up To 95° C With Accuracy Of 1° C 12 Cups And 14 Sleeves. Digital Display And Microprocessor Control System. , Water Bath / Tissue Flotation Bath Temperature Setting Range: 0 - 55°C Temperature Tolerance: +1°C Working Voltage: Ac110v 60Hz Power: 400 Va Fuse: F6a L 250Ac Glass Bowl Dimensions: 350 X 220 X 45Mm Overall Dimensions: 410 X 510 X 150Mm Weight: 9.5Kg Waterbath With Pyrex Dish The Tissue Flotation Bath Is Used For Heating A Tissue Ribbon Before Placing It On A Slide For Reading. Its Small Size And Light Weight Make It A Practical Instrument For Pathology Labs, Hospitals, Medical Schools And Scientific Research Institutions. Product Features: Bright, Digital Screen Shows Heater Working State, Temperature And Time Highest Quality American Microprocessor For Precise Temperature Control Bright Led Lighting Operating Temperature Nearly 3 Times Faster Than Major Competitors Displays Real Time Figures Of Setting Temperature, Work Temperature, Time And Work State Memory Function And Recovery Function Never Forget To Turn Off Unit Again With Programmable On / Off Timer No Troublesome Probe To Break And Flip All The Time , Orbital Shaking Incubators Temp. Range And Accuracy : Cis-24 Plus: : 5 Degree C To 60 C Ris-24 Plus :5 Degree C Above Ambient To 60 Degree C Internal Volume : 215 Ltrs Platform Size : 580X 600 Mm Maximum Shaking Capacity : 100Mlx49, 150X49, 250X33, 500X24, 1000X15, 2000Mlx9 Shaking Speed Range ( Rpm ) : 20 To 250 Shaking Amplitude: 25Mm Internal Dimensions W X D X H ( Mm ) : 660 X 765 X 650 External Dimensions W X D X H ( Mm ) : 800 X 1150 X 1300 Temperature Control: Microprocessor With Pt-100 Sensor Display : 4? Lcd Screen, Large Size Display For Ease Of Reading Power Failure Alarm: Audio Visual Alarm Door Open Alarm: Audio Alarm In Case Door Open For Over One Minute Temperature Variation Alarm : Set Temperature ± 2°C, Audio Visual Alarm Illumination : 8 Watts Fluorescent Tube Internal Body Material : Stainless Steel – 304 Grade ( Standard Models ) , Stainless Steel – 316 Grade ( Gmp Models ) External Body Material : Powder Coated Crca Steel ( Standard Models ) , Stainless Steel – 304 Grade ( Gmp Models ) Insulation ( Cfc Free Polyurethane Foam ) : 70 Mm Minimum For Body & 80 Mm For Door Noise Level : Less Than 65 Db ( A ) Recommended Voltage Stabilizer : Vs-02 , Oral Cdx Brush Biopsy Kit With Software And Computer-Printer Attachments Oralcdx - Painless Oral Brush Biopsy In Minutes. Simply Mail The Slide & Test Forms In The Prepaid Mailer To Cdx Lab Where Specially-Trained Pathologists Analyze With Assistance Of Advanced Computer Analysis. Each Oralcdx Biopsy Test Includes A Sealed, Sterile Biopsy Brush, Two Fixative Packages, A Glass Slide And Slide Holder, A Prepaid Mailer Box, A Test Requisition Form, Billing And Reimbursement Information. Ada Accepted. Includes 12 Complete Biopsy Tests And Instructions. Manufacturer Code: 12Pk Brand: Oralcdx Component ( S ) : Complete Mail In Kit Packaging: Package Of 12 Complete Biopsy Kits , Automatic Ice Flake Maker Capacity 2-10 Kg Material Ss, Ms Frequency 50-60 Hz, Phase 1 Power Source Electric, Voltage 220 V Gross Weight 36-50 Kg Usage Laboratory Pmt Detector , Horizontal Laminar Air Flow Material Of Construction - Galvanized Iron Sheet With Epoxy Polyester Thermosetting Powder Coating Of 60-80 Microns, 1.5 Mm Thickness G.I. Sheet. Anti Microbial Powder Coated / Or / Stainless Steel 304 Grade 1.2 Mm Complete. Internal Dimensions-1012 X 560 X 610 Mm ( L X B X H ) + / - 5 Mm 39.84" X 22" X 24" Inches External Dimensions - 1130 X 745 X 2025 Mm ( L X B X H ) + / - 5 Mm 44.5" X 29.33" X 79.72" Inches Velocity - 90 Fpm At 6” From Face Of The Filter + / - 20 Feet Per Minute Table Top - Stainless Steel 304 Grade 1.2 Mm Thickness Body Finish - Off White Colour Design & Classification - Front Top Loading Pre-Filters / Complete Work Area Will Be Of Ss 304 Including Hepa Grill, Table Top And Light Canopy Internal Surface. As Per Iest – Rp – Cc002.4 Cleanliness Class - Iso Standard 14644 – 1 - Class 5 Noise Level - Less Than 60 Db At 1 Meter From The Face Of The Filter Stages Of Filtration- 1 ) Pre- Filters = 10? With An Efficiency Of 90% ( Washable Hdpe Media In Frp Pu Coated Frame ) 2 ) Mini Pleat Hepa Filter Encased In Aluminum Frame Final = 0.3? With An Efficiency Of 99.995% ( Hepa Filter : Aaf India Ltd. ) Front Door - Vertical Sliding Door 6 Mm Toughened Glass With Counter Weight. Hepa Filter Grill - Stainless Steel 304 Grade Grills Duly Perforated And Polished Motor Blower Assembly- “Variable Speed Motor Mounted On Pu Coated Frp Blowers With Aluminum Impellers Switches & Speed Controller-Feather Touch Microprocessor Controlled Fluorescent Lighting - 18 Watt Slim Tubelight – 2 Nos. Chokes For Lighting - Electronic Choke 18 Watts – 3 Nos. Ultra Violet Lighting-1.5 Feet Length G15t8 15 Watt Sankyo Denki / Philips Make Electrical Socket-5 / 15 Amps Socket – 1 Nos. Side Panels -Stainless Steel 304 Grade Pressure Gauge -Minihelic Gauge ( Dwyer / Aerosense Make ) Made In U.S.A Gas / Vacuum Cock-Standard Make – Optional ( Extra Not Included In The Price ) Wheels & Leveling Lugs-Pu Solid Wheels With Plated Brackets & Metallic Leveling Lugs Power Supply & Service -Single Phase 230V, 50Hz Power Supply Consumption : 230 Watts All Services From Front And Back , Multimode Plate Readers ( Good Branded Standard Company ) Uv-Vis Absorbance-Filter Orspectrometer-Filter And Quad Monochromators-Filter And / Or Quad Monochromators Fluorescence Intensity-Filter-Quad Monochromator-Filter And / Or Quad Monochromators Luminescence Ultrasensitive Luminescence- Trf And Tr-Fret-Lamp Based2-Lamp Based-Lamp Or Laser Based2 Fluorescence Polarization Alpha ( Laser-Based ) -Alpha Standard-Alpha Hts-Alpha Standard Or Alpha Hts Alphaplex ( Laser-Based ) - - -Alpha Standard Fast Image-Based Cytometr , Ultrasonicator Power Supply, 85-260V / 50-60Hz Net Power Output, 700W Nominal Frequency, 24Khz, Real-Time Display ( 19-26Khzautomatic Frequency Scanning And Checking ) Timer, 1 Min~99H Can Be Set Power Regulation, 1%-100%, 1% Progressive Temperature Setting, 0-300 ?, 1?Progressive Store Data, 10 Groups ( Set, Store, Check In Work Status ) Pulser, Closed, Open, 1S-60Min Can Be Set Operation Mode, Pulse?Time?Continuous Lcd Display Screen, Color Touch Screen, Resolution: 400 X 240 Operational Language, English Main Interface Display Parameters, Ultrasound Output Power, Frequency, Working Mode, User Group, Setting Key, Operation Status, Start / Stop, Operation Parameters Running Interface Displays, Total Running Time, Working Time, Pause Time, User Group, Overload Temperature, Power Output Ratio, Working Mode, Program Save Key Small Bulb, Small Bulb Inside The Box Allows To Observe The Status Of The Sample During Processing. Size, 18.5×12.6×20.6In ( 470×320×525Mm ) Configuration Of Piezoelectric Frequency Converter Piezoelectric Frequency Converter, Cv33, Pzt Lead Zirconatetitanate Piezoelectric Ceramics Standard Amplifier, Aluminum Alloy Material: T1-6Al-4V Horn Diameter, 8Mm Processing Capacity, 0.1—800Ml Total Length, 105-115Mm ( Variable Ratio ) Cable Line, 150Cm , Bio-Safety Cabinet Class Ii Type A2 Material Of Construction, Galvanized Iron Sheet With Epoxy Polyester Thermosetting Powder Coating Of 60-80 Microns, 1.5 Mm Thickness G.I. Sheet. Anti Microbial Powder Coated / Or / Stainless Steel 304 Grade 1.2 Mm Complete. Internal Dimensions, L X D X H ( Mm ) : 630 X 600 X 650 + / - 5 Mm External Dimensions, L X D X H ( Mm ) : 795 X 785 X 2220 + / - 5 Mm Down Flow Velocity, 60 Fpm At 4” From The Ulpa Grill Inflow Flow Velocity, 100 Fpm Across The Work Access Opening. Body Finish, Glossy Off White Colour Design, Class Ii – A2 Compliant And Approximately 30% Of The Air Volume Exhausted As Sterile Air Back Into The Environment And Approximately 70% Of The Air Is Re-Circulated Inside The Work Area. Cleanliness Class, Iso Standard 14644 -1 Iso Class 3 Noise Level, Less Than 60 Db At 1 Meter From The Face Of The Filter Stages Of Filtration, Ulpa Final = 0.12? With An Efficiency Of 99.9995% Ulpa Exhaust = 0.12? With An Efficiency Of 99.9995% ( Ulpa Filter : Aaf India Ltd. ) Front Door, One Piece Full View Frame Less Sliding Toughened Glass Door 6 Mm Thick. Motorized Automatic Door. Ulpa Filter Grill, Ss 304 Grills Duly Perforated And Polished Motor Blower Assembly, “Godrej” Make Variable Speed Motor Mounted On Pu Coated Frp Blowers With Aluminum Impellers Switches & Speed Controller, Feather Touch Microprocessor Control Fluorescent Lighting, “Osram” Make. 18 Watt Slim Tube Light- 2 Chokes For Lighting, “Wipro” Electronic Choke 18 Watts – 2 Nos. Ultra Violet Lighting, 1.5 Feet Length G15t8 15 Watt “Philips” Make Electrical Socket, 5 / 15 Amps Socket – 1 Nos. Internal Work Area, Complete Stainless Steel 304 With Rounded Joint Less Corners Pressure Gauge, Magnehelic Gauge Gas / Vacuum Cock, Standard Make ( Premier Make ) Wheels & Leveling Lugs, Pu Solid Wheels With Plated Brackets & Metal Leveling Lugs Power Supply & Service, Single Phase 230V, 50Hz Power Supply Consumption : 350 Watts All Services From Front And Back Alarm For Excess Height Opening And Automatic Cutoff For Uv Tube When The Door Is Open. Interlocked Switches For Uv & Lights. Stainless Steel Drain Collection System Raised Arm Rest Prevents Grille Blocking, And Provides Comfortable Working Posture. Single-Piece Work Tray To Contain Spillage With Sloped Easy-To-Swipe Perimeter. System Is Ergonomically Designed With Angled Cabinet Front Which Is Sloped At Around 10° For Enhanced Comfort And Reduced Operator Fatigue. For Easy Servicing All Cabinet Components, Including Ulpa Filters Are Easily Accessible From The Front / Back To Allow For Rapid Service And Minimal Work Disruption During Preventative Maintenance And Recertification. System Will Comply With Nsf / Ansi 49 To Ensure A Safe Operating Environment For Class Ii, Type A2 Conditions , Microprocessorbasedph Meter Features: - Measure Ph, Mv & Temperature Highly Accurate & Easy To Operate Auto Temperature Compensation Facility 7 Segment Bright Red Led Display Soft Touch Membrane Keys Instrumentto Provide The Precise Ph, Mv And Temperature Measurements With Auto Buffer Recognition For 4.00, 7.00 And 9.2 Ph Buffers And Auto 2 Or 3 Points Buffer Calibration. With 7 Segment Bright Red Led Display With Latest Microprocessor Technology And Advanced Engineering Techniquesto Give Enhanced Accuracy And Reproducibility.6 Soft Touch Membrane Type Keys For Ease Of Operation. Calibration Should Be Retained Even After The Instrument Is Switched Off Specifications Parameters, Ph, Mv, Temp Range, 0 - 14.00 Ph, 0 - ±1999, 0 - 99.9 °C Resolution, 0.01 Ph, 1 Mv, 0.1 °C Accuracy, ± 0.01, ± 1 Digit, ± 1 Mv, ± 1 Digit, ± 0.1 °C Relative Stability, 0.02 Ph / Hour Acceptable Electrode Slope, 80% - 120% Temperature Compensation, 0 - 100 Oc Auto / Manual Temperature Sensor, Semi-Conductor ( Lm35 ) Type Calibration, Auto ( 2 Or 3 Point ) Auto Buffer Recognition, 4.00, 7.00 & 9.20 Ph Readout, 7-Segment Bright Red Led Display ( 3 For Temperature And 4 For Ph / Mv ) Key Board, 6 Keys, Soft Touch Membrane Type Power Supply, 230V + 10% Ac, 50 Hz. Accessories, Combination Ph Electrode, Buffer Tablets ( 7.0 And 4.0 Ph ) , Temperature Probe, Electrode Stand, Mains Lead, Operation Manual And Dust Cover
|