Construction Of State Level Laboratory At Sidhpur In Tehsil Dharampur District Mandi ( Hp ) Providing, Supplying And Installation Of Various Equipments, Glasswares And Chemicals For State Level Laboratory , Schedule I :- Providing, Supplying And Installation Of Various Equipments Of Specified Make As Per Following Techincal Conditions, Sepecification And Requirement Complete Within All Respect As Per Direction And To The Entire Sartisfaction Of Engineer- In- Charge. , Ph Meter ( Both Lab Based And Portable Type ) , Digital Display ( 0-14 Range ) Of Hanna Instrument / Uk Makemeasure Ph, Mv And Temperature Automatic Calibration Auto Buffer Recognition Auto Temperature Compensation Range : 0-14 Ph Accuracy: +0.01 Accessories: Ph Electrode, Temperature Probe, Electrode Stand, Buffer Solution, Dust Cover & Manual, One Spare Combination Electrode , Tds / Conductivity Meter ( Both Lab Based And Portable Type ) , Direct Reading Digatal Display ( Ce Certified ) Of Hanna Instrument / Usa Makerange: 1 Micro S To 100 M S / Cm Accuracy: ± 1 % Of The F.S ± 1 Digit. Display: Led, 4 Digits For Conductivity, 3 Digits For Temperature Accessories. One Spare Conductivity Cell, Cell Constant 1.0 Temperature Probe, Electrode Stand, Dust Cover , Operation Manual , Nephelometer ( Turbidimeter ) , Direct Reading Range:0-100 Ntu Of Takahe Make Measurement Method Ratio Turbidimetric Determination Using A Primary Nephelometric Light Scatter Signal ( 90° ) To The Transmitted Light Scatter Signal. Light Source 2100Q: Tungsten Filament Lamp 2100Qis: Light-Emitting Diode ( Led ) @ 860 Nm Range 0 To 1000 Ntu ( Fnu ) , Digital Balance, Single Pan Cap. 200 Gr. Tarring Device Accuracy-0.0001 Gm Of Make• Capacity: 220G • Minimum Display:0.001G • Repeatability ( Standard Deviation ) : S=0.001G • Linearity: ±0.02G • Response Time ( Approx. ) :1.0-1.2 Sec • Ambient Temperature:5-40°C / 41-104°F • Temperature Coefficient Of" Sensitivity ( 10-35°C ) :±3Ppm / °C • Pan Size ( Mm ) :100×100 ( Mm ) • Weight ( Approx. ) : 2.2 Kg • Power Requirements: Ac Adapter; 90V-264V, -15%-+10%, 50 / 60Hz • Standard Accessories: Simple Windbreak ( Brown Smoke Color ) • With Certificate From Legal Metrology Department , Uv-Visible Spectrophotometer, Should Cover Wavelength Of Important Of Klab / Shimadzu / Agilent / Analytic Jena / Perkin Elmer Or Equivalent Make Quantitative And Qualitative Analysis Of Organic And Inorganic Compound Including Pesticides, Heavy Metals Etc. In Ppm Level Brief Description Of Equipment Microprocessor Based Wavelength Range: 190 To 1100 Nm With Lcd / Led Display • System Should Be Double Beam Uv-Visible Spectrophotometer With 8-Cell Changer • The Monochromator Should Be Blazed Holographic Grating With 1200Lines / Mm, • The Detector Should Have Si-Diodes / Ccd Or Equivalent • System Shouldhave Wavelength Range From 190 To 1100 Nm Or Better • System Spectral Bandwidth Should Be 1 Nm ( 190 To 1100 Nm ) • Wavelength Setting Should Be 0.05 Nm • Wavelength Accuracy Should Be ±0.3 Nm • Wavelength Repeatability Should Be <± 0.1 Nm Or Better • Scan Speed Max 6, 000 Nm / Min Or Better • Photometric Range Absorbance : -4 To 4 Abs , • Transmittance Range Should Be : 0 % To 400 % • Photometric Accuracy Should Be Less Than ± 0.005 Abs At 1.0 Abs • Light Source Tungsten Halogen Lamp & Deuterium Lamp • Photometric Repeatability ± 0.0002 At 0.5 Abs • Baseline Stability: < 0.0003 Abs / H • Operating System ( Os ) : System Should Have Touch Screenand Windows 10 ( Embedded Pc ) Option Also. • Cuvettes With 3.5 Ml - 1 Pair Should Be Quoted. • Computer: Workstation With Processor Intel Core I5-4670 Processor ( 3.4Ghz, 6M Cache ) , Hdd 1Tb 7200Rpm, Graphics: Intel Hd Integrated Graphics, Memory 4Gb X 2 Dimm 1600Mhz, Optical Dvd Recordable, Wireless Wifi Operating System Window 7 Or Above, Cordless Mouse And Keyboard Should Be Quote . , Refrigerator, 295 Lts. Cap. ( Lg / Samsung ) Of Lg / Samsung Make Vertical Cooler ( With Front Glass Door ) Should Be Able To Maintain 4 C Capacity: 500 L Accessory: Voltage Stabilizer , Muffle Furnacefinishing: Powder Coated Material: Mild Steel Heating Range: Upto 1150 Degree Celsius Heating Space: 120 To 350 Cubic Inches Power: 230 V, 50 Hz, Single Phase , Voltage Stabilizer / Inverters Of Make ( 10Kw ) Online 20Kva Ups System With Isolation Transformerfor Uninterrupted Power Supply. , Electric Hot Plate ( Digital ) , Big Size Ce Certified Screen Type-Digital Plate Dimensions-300 X 300 Mm Heater Power-600 W Minimum Set Temperature-50 Deg C Display Resolution-1 Deg C Max Plate Temperature 300 Deg C , Heating Mantle, Cap. 1 Lt. Heating Mantle 1000Ml In 220 Volt Item Shape: Round Dimensions : 28.2 X 19.4 X 17 Cm; 1.58 Kilograms , Water Bath, Big Size ( 12 Hles ) Temp. 500 Degree To 1000 Degree Centigrade Ce Approved. 1. Double Walled Outside Made Of Of Ms Duly Powder Coated And Inner Chamber And Lid Made Of Stainless Steel. 2. The Gap Of 25Mm Between Outer And Inner Walls Is Insulated With Mineral Wool. The Top Of The Bath And The Concentric Rings Are Made Of Ss 304. 3. The Temp. Is Controlled By Thermostat / Microprocessor Based Pid Digital Temp. Controller. Temperature Range: Ambient To 100 Deg.C. 4. The Bath Is Provided With Two Indicating Lamps, Concentric Rings, On / Off Switch, Wire And Plug, Without Thermometer. 5. Capacity: 20 L 6. Temperature Range: Ambient To 100 C With Accuracy Of + 0.5 C , Hot Air Oven, Stadard Make- Big Size Double Walled, Outer Made Of Gi Duly Powder Coated And Inner Ss 304. Perforated Adjustable Shelves. With Provision To Keep Thermometer. Temperature Range ( + ) 50 To 250 Deg. Celsius, Accuracy ±1Deg, Controlled With Microprocessor Based Pid Controller. Fitted With Air Circulation Fan.Preferable Size- 455X455x605 Mm, 605X605x605 Mm. , Bacteriological Incubator, Temp. Control Device ( Range 0 To 50 Degree Centigrade ) Medium Size Ce Certified. Inner Chamber Sizes In Mm: W X D X H = 455 X 410 X 610, Capacity In Cu. Ft. : 4 Cu. Ft., Material: Inside Stainless Steel Chamber Epoxy Coated Outside Capacity Approx. : 112 Ltr., Range: 35 To 60 O C, Thermostatically Shelves: 3Nos. Controlled S.S. Camber, Co2 / Air Mixer Nozzle Is Provided , Autoclave, Medium Size Steel Cabinet Double Walled Construction, Outer Made Of Ss 304. Inner Chamber Made Of Ss 304 With Ss 304 Lid. Unit Fitted With Double Safety Radial Locking System With Paddle Lifting Device, Made Of Ms Chrome Plated, With Built-In Safety Valve, Pressure Gauge, Pressure Release Valve And Water Level Indicator. Pressure Adjustable From 5 Psi To 20 Psi With An Accuracy Of ± 1 Psi, With Automatic Pressure Control Switch. Supplied Complete With Stainless Steel Basket, Cord And Plug. The Autoclave Should Have Electrically Heated By Immersion Type Heaters Suitable To Work On 220 Volts Single Phase 50 Cycles. The Pressure Inside The Chamber Should Be Variable From 5 Psi. To 20 Psi Working Temperature: 121°C Hydrostatic Pressure: 2.5 Kg / Cm Sq. The Unit Is Fitted With Steam Release Valve, Spring Loaded Safety Valve , Water Inlet And Water Outlet Valves, Water Level Indicator , Pressure Gauge, Electrical Control Box, Fitted With Toggle Switch, Indicating Neon Lamps And Steam Release Valve, Paddle Lifting Device And Automatic Pressure Switch. Automatic Pressure Control Switch – To Cut-Off The Current From The Heating Elements, When The Desired / Set Pressure Value Level Is Attained Inside The Chamber And Restarts The Mechanism Once The Pressure Inside The Chamber Falls From The Desired Level. Automatic Water Cut-Of Device To Protect The Heaters From Running Dry And To Ensure That The Machine Is Automatically Switched Off In Case The Desired Water Level Falls Below The Prescribed Level. ( Optional ) Programmable Digital Temperature Indicator Cum Timer With Alarm System : Programmable Microprocessor Based Pid Digital Temp. Indicator Cum Controller With Digital Timer With Automatic Steam Release After Completion Of Cycle. , Magnetic Stirrer With Hot Plate, With Speed Control And Teflon Paddle Ce Certified, Beaker Capacity Up To 2000Ml, Rpm Up To 2000 Ml ( Without Load ) , Hotplate Temperature Ambient To 100°C, Heater: 230 Watts, Power: 220 / 230V Ac, Dimension 182 Mm X 235 Mm X 142 Mm, Rotor Magnet, Top Plate Size: 10 X 10 Cm, Top Plate Material: Ceramic , Microscope, Binocula Laboratory Binocular Microscope • Magnification - 50X – 1000X. • Observation - Binocular 45°, 360° Rotatable, With Interpupillary And Diopter Adjustment. • Stand - A Rigid & Heavy Stand. • Focusing - Coarse And Fine Focusing By Conveniently Placed Separate Knobs 1 Div. 0.002 Mm. • Stage - Horizontal Mechanical Stage 120 X 140 Mm. With Fine Vernier Graduation. Designed With Convenient Co–Axial Adjustment For Slide Manipulation Through 50 X 70 Mm. • Illumination - The Illuminator Incorporated 3W Led Lamp. • Condenser - Sub Stage Abbe Filter Holder N.A. 1.25 Condenser With Iris Diaphragm And Swing Out Filter Holder Focusable By Rack & Pinion. • Nose Piece - Quadruple Revolving Nose Piece With Positive Click Stops. • Objectives - Achromatic 5X, 10X, 45X & 100X Oil ( Sl ) . • Eye Pieces - W.F. 10X Anti Fungus Coated. ( Paired ) F.O.V.18 Mm. , Filter Paper 125Mm ( Pack Of 100 Pec. ) Pore Size: 20-25 ?M ( Particle Retention ) Material: Circles, Cotton Filters ( High-Quality Cotton Linters ) , Flame Photometer Elico / Kniss / Systronics / Pc Tech Make Display: 20 X 4 Line Alphanumeric Backlit Display. Range: Na, K, & Li 1-100 Ppm And Ca15-100 Ppm Dimensions-290 X 255 X 210 Mm ( L X B X H ) ( Approx. ) Flame System: Lpg Dry Oil Free , Vortex Shaker Variable Speed Control Max Speed 300 Ppm , Inductively Coupled Plasma-Mass Spectormetry ( Icpms ) Of Reputed Make Conforming To Iso / Ce Certified Standards. The Icp Mass Spectrometer For Heavy Metal And Other Elements Measurements In Drinking Water, Potable Water And Any Sample Matrix From Jal Shakti Vibhag. 1. Purpose- Analysis Of Trace Metals In Drinking Water & Ground Water As Per Bis, Fssai And Related Regulatory Guidelines. 2. Equipment Must Be The Latest Model And Design As Per The Internationally Approved Testing & Measurement Parameter. 3. Basic Design-Latest And Advanced Technology Bench-Top Icp-Ms With Cell Collision & Reaction Mode. The System Should Complete In All Respects With Built In Features Of Hardware & Software. 4. Sample Introduction – • Integrated Computer Controlled Minimum 3 / 4-Channel Peristaltic Pump. • Integrated Peltier Cooled Spray Chamber ( -5 To 20°C Or Or Better ) To Analyze All Kind Of Specified Samples And Comply All National And International Regulations. • Integrated Software Controlled Dilution: Should Have Suitable Automated Controlled Integrated Dilution With 10 Or More Fold Dilution Capability To Analyze All Kind Of Specified Samples And Comply All National And International Regulations. • Standard Kit To Be Offered Along With Splitter & Tubing Set 5. Plasma And Torch Setup • Rf Power Range:500-1600W Or Better • Rf Generator: 27 / 40 Mhz • Torch Alignment: X, Y, Z Automatic And Computer Controlled • Flow Controller: Should Have At Least 2 Or More Flow Controllers For Control Plasma, Auxiliary Makeup, Carrier Gases And Makeup / Dilution Gas. 6. Interface , • Cone Interface: Icpms System Must Have Single Cone Interface To Achieve All Guaranteed Performance Specifications Icp-Ms Instrument Without Any Manual Intervention Or Changeover For High Matrixes, High Sensitivity And High Tds Samples • Ion Lens: Off-Axis Ion Lens Or Suitable Design To Provide High Ion Transmission And Low Backgrounds To Deliver Superior Detection Limits, Sensitivity And Oxide Ratio. 7. Collision Reaction Cell • System Equipped With Best In Line Technology • Capable Of Operating In Standard ( No Gas ) , Collision Modes, Reaction Mode ( Pure Or Premix Gas Form ) Should Be Able To Remove Polyatomic Interferences As Per All National And International Regulations. • Fully Automated And Software-Controlled Changeover Between No Gas, Collision And Reaction Mode Without Any Manual Intervention • Separate Gas Lines With Dedicated Flow Controller For Collision And Reaction Gas With Automatic Control Must Be Supplied In Icp-Ms To Comply All National And International Regulations ( I.E. He, H2, O2, Ch4 & Nh3 ) , 8. Mass Analyzer And Detector • Quadrupole Must Be Minimum 2.5 Mhz Or Better • Mass Range: 5-258 Amu Or Better To Analyze All Elements. • True Linear Dynamic: 11 Orders <0.1Cps >10¹ºcps Or Better Without Any Hardware Interchange Or Software Adjustment • Dwell Time: 100 ?S Or Better • Scan Speed: >3000 Amu / Sfrom Li To U Plus40 Intervening Masses Or Better 9. Detection Limits: • Low Mass ( Be / Li ) : =0.5 Ppt Or Better • Mid Mass ( Y / In ) : =0.1 Ppt Or Better • High Mass ( Ti / Bi / U ) : =0.1 Ppt Or Better 10. Sensitivity: ( Guaranteed Factory Specifications Will Be Considered & Not The Typical Performance ) • Low Mass ( Be / Li ) :=55 Mcps / Mg / L Or Better • Mid Mass ( In / Y ) :=200 Mcps / Mg / L Or Better • High Mass ( Te / Bi / U ) := 250 Mcps / Mg / L Or Better • U Typical Sensitivity:= 300 Mcps / Mg / L Or Better • Oxide Ratio ( Ceo+ / Ce+ ) : <2% • Ba++ Or Ce++ / Ba Or Ce :<3 Or Better • Background Mass 4.5 / 9 / 220: No Gas <1 Cps • Short Term Stability :<3% Rsd Or Better , 11. Vacuum System- Suitable Turbo Molecular Pump, Corrosion Resistant And Protected. 12. Software- Windows Based Software User-Friendly That Guide Users Through Method And Sequence Development And Method Templates For Rapid Development Of Commonly Used Methods. ( The Quoted Software Should Be 21 Cfr, Part-11 With Qa / Qc Calculation Capacity & Minimum ( Two ) Offline License. 13. Standard Accessories Required I ) Autosampler: Minimum 200 Vials Or More Samples Capacity, Complete Sealed / Covered Enclosure. 1000Nos Vessel. Ii ) Setup And Detection Solutions: All Setup And Detection Solutions Quoted Should Be Certified, Traceable To Nist. Iii ) Nist Calibration Standards: A. 1643 Nist Traceable Standard For Trace Metals In Drinking Water , 500 Ml B. 23 Element Surface Water Standard , 250 Ml C. 22 Elements 6020 Epa Standard For Water , 250 Ml D. Tuning Solution, 125 Ml E. Genuine Licensed Software For Icpms And Iq Oq Documents F. Pc & Printer.Ms Office Should Be Offered. 14. Consumables ( All The Consumables Should Be Quoted & Specified With Oem Alongwith Specified Qualities. ) • Ni Sampler & Skimmer Cone ( 02 Sets ) • Standard Injector & Torch -05 Nos. • Standard Spray Chamber -03 Set • Standard Nebulizer: 02 Set , • Standard Peristaltic Pump Tubing For Drain Pk / 12 -15 Set • Standard Peristaltic Pump Tubing For Samples Pk / 12 -15 Set • Peristaltic Pump Tubing For Istd Pk / 12 -10 Set • Pfa / Suitable & Rinse Tubing -10 Set • Oil Element / Mist Filter -01Set • Pump Oil – 1 Ltrs • Tubing For Drainage -10 Set • Tubing For Reaction Cell Gas ( If Applicable ) , 1 / Pk ( 08 Nos ) • Rf Coil -02 Set • Cone Cleaning Solvent / Chemical -3.5 Ltr • Swab-Cotton Tipped Both Ends Pk / 100 – 3 Pac • Autosampler Vials -2000 Nos. • Autosampler Tubing Set P / 12 -05 Sets • Autosampler Probe: 02 Set • Tubing For Spray Chamber Drain -10 M • Fluid Filter For Chiller -02 Sets 15. Warranty- Three Years On Complete Supplied System From The Date Of Installation Along With Ups, Pc, Printer, Gas Panel. 16. Training - Three Days Training For Staff At Our Laboratory. Five Days Training At Vendor’S International Training Center Including Boarding, Lodging & Travelling Cost ( For Two Personals ) . 17. All Supporting Published Documents Must Be Enclosed For Specified Specifications, Along With Published Tender Specifications. 18 Price Must Be Quoted In Inr And F.O.R Site Including Clearance And Transportation. 19 User List Has To Be Attached For The Quoted / Equaling Model. , Uv Laminar Air Flow Chamber For Bacteriologicalanalysis. • Cabinet Is Fabricated Out Of The Stainless Steel 304 Grade • The System Is Microprocessor Based. The Microprocessor Displays The Inflow And Down Flow Air Velocities In Real Time On An Lcd Display. • Motor Automatically Adjust The Air Flow Speed To Ensure Continuous Safe Working Condition. Air Flow As Per Requirements Of Bio Safety Regulations In Respect Of Atleast Bsc Ii A Level Cabinet. • Noise Level Less Than 65 Decibel. • Efficiency Of Hepa Filter Is Almost 99.97%. • Working Table Made Of Ss 3004. • Front Of The Cabinet Shall Be Angled To Help Minimize Glair. • Fluorescent Lamps For Lighting Of The Interior Of The Cabinet. • Uv Light Is Also Fitted To Disinfect The Interior Of The Cabinet. Uv Light Shall Be Programmable To Allow For Specific Exposure Time From 0 To 24 Hrs. Automatic Uv Switch Off‘ On Opening Of Front Window. The Front Window Is Made Of Laminated Safety Glass To Protect Against Leakage Of Uv Rays And To Ensure Containment Of Potential Hazardous Material. • Safety Alarm / Safety Display For Low Air Velocity And Faulty Exhaust Fan. • Power Input 220-240 V Ac, 50 Hz Fitted With Indian Plug. • Movable Stand • Dimensions: 2’X2’X2’, 3’X2’X2’, 4’X2’X2’ And 6’X2’X2’ , Micronfiltration Assembly With A Vacuum Pump Of Borosil Make Chemical Duty Pump, 220 V / 50 Hz, Ac Powered And Source Of Vacuum To 585Mm / 23 Hg ( At Mean Sea Level ) Or Pressure To 4 Bar / 58 Psi For Filtration Of Liquids Or Other Continuous Or Intermittent Use With All Types Of Filter Holders , Plate Count And Colony Counter Of Stadard Make Digital Colony Counter For Quick And Accurate Counting Of Bacterial And Mould Colonies In Petri Dishes. It Should Be Designed For Rapid And Accurate Counting Of Bacterial And Mould Colonies. Simply Place The Petri Dish On The Illuminated Pad And Touch The Dish With The Pen Provided To Mark Each Colony In Turn. This Causes A Count To Be Registered On The Digital Display And Audible Tone Confirms Each Count Made. Marking The Dish With The Pen Avoids Missing Colonies Or Double Counting. The Digital Count On The Display Can Be Reset Manually Any Time By Pressing The Reset Key Provided. Optimum Viewing Of Colonies Is Aided By Peripheral Glare-Free Illumination. An Integral Magnifying Glass Provides For Easier Counting Of Small Colonies. Technical Specifications Display : 4 Digit, 9999 Max. Count ; 3 Digit, 999 Max. Count Dish Size : 110 Mm Magnification : X 1.7 Memory : 50 Test Counting Plate : Illuminated Wolfhugel Power : 230V-10% Ac, 50Hz, 40W Accessories : Marking Pen- 1 No. ; Magnifier Lens- 1 No. Salient Features Count Correction Facility 110 Mm Dia Magnifying Glass Audible Confirmation Of Each Count. Uniform Glare Free Illumination Digital Readout From 0-9999 Auto Maker Pen. , Lpg Burners & Fittings Isi Marked / Bis / Equivalent As Per The Site Layout And Drawing. , Field Kit ( Ph, Conductivity, Tds &Do ) System To Be Used For Water Quality Field Applications Measuring Simultaneously Two Of The Following Parameters: Ph, Conductivity / Tds & Dissolved Oxygen ( Do ) 1. It Should Be Waterproof Portable Logging Multiparameter Meter That Monitors Up To 12 Different Water Quality Parameters Including 6 Measured And 6 Calculated. 2. The Microprocessor Based Multi-Sensor Probe Allows For The Measurement Of Key Parameters Including Ph, Orp, Conductivity, Dissolved Oxygen, And Temperature. 3. The Probe Transmits Readings Digitally To The Meter, Where Data Points Can Be Displayed And Logged. 4. It Should Be Supplied With All Necessary Accessories And Packaged In A Durable Carrying Case. 5. It Should Have Minimum 12 Parameter Dot Matrix Display 6. Multi-Sensor Probe Should Be Quoted 7. Quick Calibration , Coolbox With Icepacks Ice Box Of 15Ltr Make: Cello Or Millton , Specific Ion Meter Along With Electrodes ( For Fluoride And Nitrate Etc. ) , Digital Portable Hach Equipment For The Measurement Of Fluoride, Nitrate, Lead, Cyanide And Silver Ions Concentration With The Following Specification Is Required. 1. The Equipment Should Be A Microprocessor Based Ph Ion Meter With Graphic Display Along With Suitable Sensors. 2. The Equipment Should Have A Graphic Lcd Screen, A Sensor Input To Connect Ph Or Ion Selective Electrode & A Socket To Connect A Pt1000 Or Ntc Temperature Sensor. 3. The Equipment Should Have The Facility To Determine The Content Of Ions Using Suitable Ion-Selective Electrodes.The Determinations Are To Be Performed By Establishing Calibration Curves And By Carrying Out Standard Additions. 4. The Instrument Should Have The Facility To Connect An Electronic Burette Directly For Standard Addition Purpose. 5. The Equipment Should Have The Facility To Automate The Standard Additions Using Suitable Dosing Device.It Should Have The Possibility Of Using At Least 15 Different Concentrations Of Standards For Calibration. 6. The Equipment Should Have The Facility To Perform Ph Measurement And The Calibration With Upto 9 Different Ph Buffers. 7. The Equipment Should Have The Facility To Connect And Control A Magnetic Stirrer Or A Rod Stirrer. 8. The Equipment Should Have The Facility To Simultaneously Display Ph And Temperature. 9. The Equipment Should Have A Drift Indicator With Graphic Display Plot Of Measured Value With Time For Ph, Mv, Temperature And Concentration. , 10. The Ph Ion Meter Provided Should Have The Following Measurement Range: Ph Range : From 0 To + 14.000 Potential : From –2200Mv To + 2200 Mv Temp Range :-150.0 Oc To +250.0 Oc Concentration :10-38 To 10+38 And The Following Resolution: Ph: 0.001 Mv:0.1 Mv Temperature: 0.1 Oc 11. The Equipment Should Have The Memory For Storing Minimum 100 Measured Values. 12. The Equipment Should Have Automatic Monitoring Of Validation, Service And Calibration Intervals. 13. The Equipment Should Have An Interface To Connect Pc Or Printer. 14. Instrument Should Be Supplied With Ion Selective Electrode For Ammonia, Nitrate, Chloride, Fluoride And Cyanide Ions Measurement, Along With Ag / Agcl Reference Electrode With Necessary Cables And Accessories.Suitable Electrode To Measure Ph Also Should Be Provided. , Fume Coup Board, Material-Stainless Steel Floor Area-0.75 M X 0.75 M Compressed Air Supply 2 Bar, 2.5 Cfm Electricity-1 Phase, 220 V, 50 Hz Ac , Extraction Thimble, Temperature Resistance-400 Degc Color-Transparent Material-Borosilicate Glass 3.3 Maximum Temprature Capacity 400 Degc Isi Marked / Bis / Equivalent , Digital Temp Sensor Digital Thermocouple With Led / Lcd Display. , Stop Watch Digital With Led / Lcd Display. , Thermometers Of Npn Make, Temperature Range -50.0 To 150.0 ºc / -58.0 To 302 ºf Temperature Resolution 0.1 ºc ( -50.0 To 150.0 ºc ) Temperature Accuracy ±0.2 ºc ( -30.0 To 120.0 ºc ) Automatic Shut-Off 8 Min ( Default ) , 60 Min Or Off Battery Type / Life 1 X Cr2032; Approx. 2000 Hours Of Continuous Use Environment -30 To 50 ºc ( -22 To 122 ºf ) , Weight Box, Stainless Steel Laboratory Weights Certified By Bis 1Mg To 200 Gm Class F1 ( 1Mg To 200 Gm ) , With Calibration Certificate From Nabl Certified Laboratory , Double Distillation Apparatus / Ultrapure Water Purification System To Provide Type1 / Type 11 Water For Sophisticated Instruments, Material: Stainless Steel Capacity:1.5 Litre / Hr, 2000 W. Power Supply: 220Vac ± 25%, 47 To 53 Hz Protection: Automatic Power Cut Off At Low Water Level Conductivity: The Conductivity After Distillation Shall Be Equal To Or Less Than 0.01Ms / Cm At 25Oc , Bulb Rubber ( 10Mm ) Isi Marked / Bis / Equivalent , Kjeldal Distillation Apparatus, Kjeldahl Apparatus Is Used To Determine Organic Nitrogen ( N2 ) And Protein Contents In Water Samples And Chemical Substance. Units Of Test-6 Test Heater-Mantle Type Flask Capacities-300 Ml / 500 Ml Max. Temperature-350°C Rating-200 Watts Construction-Ms Powder Coated Accessories - Glass Ware - Clamps - Lead Fume Duct - Condenser Rack , Bulb Rubber ( 20Mm ) Isi Marked / Bis / Equivalent , Bulb Rubber ( 25Mm ) Isi Marked / Bis / Equivalent , Pcr Mechine, Preferable Specifications: • Sample Capacity 96X0.2Ml Pcr Tube, 8X12 Pcr Plate Or 96 Well Plate • Heating Temperature Range 4-105? • Lid Temperature Range 30-110? • Temperature Display Accuracy ±0.1? • Temperature Control Accuracy [ At 55? ] ±0.3? • Temperature Uniformity [ At 55? ] <0.3? • Max. Heating / Cooling Rate 5?Sec • Gradient Temperature Setting Range 30-99? • Gradient Range 1-42? • Adapter Block Material Aluminum • Display 7” Lcd 800X480 • Input Touch Panel • User Defined File System Max. 30 Segments 99 Cyclesmax. 16 Folder And 16 Files Each Folder • Power Off Protection Yes , Deep Freezer ( -20 Oc ) , Ce Certified, Vertical Deep Freezer ( -20 C ) Digital / Mechanical Temperature Control, Alarm System, Environmental Friendly. Capacity280 Ltr. Or More, Cfc Free Refrigerant, Microprocessor Controlled Temperature, Caster Wheels, Voltage Stabilizer, Rs 232 / Rs 485 Interface For Temperature, Date And Time.Accessory: Voltage Stabilizer , Micropipette ( 10Ml ) Of Borosil Make, Isi Marked, A Class, Variable Volume Air Displacement Single Channel Pipettes Requiring Both Precision And Accuracy. 1-5 Ml And 1-10 Ml And Stand Different Size. , Centrifuge, Labpro Centrifuge • General Purpose Bench Top Laboratory Centrifuge Machine. • Heavy Duty Crc Construction Finished With Powder Coating. • Double Walled Abs Injection Moulded Lid Which Is Light Weight To Avoid Accident. • Inter Lid Lock And Metallic Centrifuge Bowl For Safety. • 2 Lines Of 16 Character Lcd Display Of Rpm, Rcf, Set Time And Run Time. • Microprocessor Based Programmable Speed Control From 500 To 5200 Rpm Depending Upon The Type Of Rotor And Digital Timer ( 0-59 Minutes ) . • Last Test Parameter Recall And Display Automatically On Lcd. • Low Noise, Smooth And Soft Start And Stable Speed Output. • Wide Variety Of Rotors And Reduction Adopters Available On Demand At Extra Cost. • The Lid Is Light In Weight To Avoid Accident Due To Heavy Weight Metallic Lids During Operations. • Motor Fitted On Anti Vibration Spring Pads. Supported With Rubber Covering From Inside And Outside. • Maximum Speed 5250 Rpm • Maximum Rcf ‘G’ 3600 • Maximum Capacity 400 Ml • Motor Universal Motor ( Fitted With Carbon Brushes ) With Rotor Should Be Quoted. , Reflux Apparatus / Cod Digester, Multi Parameter Photometer, With Cod Digester / Reactor. The Benchtop Photometer Should Measures 36 Different Key Water And Wastewater Quality Parameters Using Different Methods That Allow For Multiple Ranges And Variations In Chemistry For Specific Applications • Should Have Digital Ph Electrode Input Allowing The User To Measure Ph By A Traditional Glass Electrode With Built In Microchip Within The Probe That Stores All Of The Calibration Information • System Should Have Silicon Photodetector For Absorbance Measurement • Chemical Oxygen Demand Resolution 1Mg / L • Cod Test Tube Heater Should Have Two Predefined Temperature Profiles: 150ºc And 105ºc Selectable By User. • The Entire Temperature Range Should Be -10°C To 160°C • Cod Tube Heater Should Have 25 Well Position For 25 Samples. • Cod Reactor Should Have Built In Temperature Alert, Timer And Status Indicator Light. • In Addition To The 25 Vial Capacity Of The Aluminum Heating Block, A Small Well Is Available For A Temperature Probe For Users That Wish To Verify Their Heating Block. • System Should Have Lcd Display , Bulb Rubber ( 50Mm ) Isi Marked / Bis / Equivalent , Burette Stand Of Borosil Make, Low Expansion Borosilicate I.D. Control Tubing. Ÿ Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1997 And Iso 385. Supplied With Ptfe Stopcock, Boroflow Stopcock And Straight Bore Glass Stopcock , Spatula S.S., 200 Mm, Compatible For Analytical Grade Use, Isi Marked / Bis / Equivalent , Gas Chromatography-Mass Spectrometry ( Gc-Ms ) Of Reputed Make Conforming To Iso / Ce Certified Conforming To International Standards1.Gas Chromatography: A. Gc Oven • Temperature Range- 4 Deg Above Ambient To 450°C • Ramp Rate- 120°C / Min. Or Better • Heating Ramps Atleast 20 Ramps / Programming Steps Or More. Cooling Ramps Also Required To Cool Down Gc • Cooling-Fast Cooling Of Oven 450 To 50 Deg C Within 4-5 Minutes Or Faster 2. Gc Inlets - 2 Nos Of Split / Splitless Injector – 1 No. And Programmable Temperature Vaporizer ( Ptv ) - 1 No. • Temperature Range Up To 4000C Or Better. • Split Ratio Setting Range: Up To 7500 Or More • Pressure Setting Range: 0 To 145 Psi Or Better For Split / Splitless And 0 To 100 Psi Or Better For Ptv With Increment / Resolution / Control Of 0.001 Psi For The Entire Pressure Range • Compatible Columns With Different Internal Diameters From 0.1 To 0.53 Mm Or Suitable For All Capillary Columns ( 50 To 530Umi.D. ) 3. Gas Saver Mode To Reduce Gas Consumption, Electronic Septum Purge 4. Electronic Pressure / Flow Control: The Pressure And Flows Must Be Independently Controlled For All Injectors And Detectors Through Software Only. System Should Have Constant Pressure, Constant Flow. , 5. Auto-Sampler: Liquid Auto-Sampler With 100 Vials Capacity, For 2 Ml Vial Capacity 6. Ms Specifications: Fully Pc Controlled Mass Spectrometer With Highly Efficient Turbo Molecular Pump With Ei • Mass Analyzer: Single Quadrupole Mass Filter With Pre-Filter / Pre-Rod, Compatible With 0.1 To 0.53 Mm Id Columns For Various Samples / Applications Or Heated Quadrupole • Mass Range: 10 To 1050 Amu Or Better • Scan Speed: 20, 000 Amu / Sec Or Better • Mass Resolution: Unit Or Better • Mass Axis Stability- Should Be + / - 0.10 U / 48 Hrs Or Better. • Ei Voltage: Up To 150 Ev Or More • Ionization / Emmission Current: Variable 10-150 ?A Or Better • Ionization Mode: Electron Ionization • Sensitivity ( Signal / Noise ) : Ei Scan: 2000:1 S / N For 1 Pg / ?L Ofn ( To Be Demonstrated At The Time Of Installation ) Or Idl ( Instrument Detection Unit ) In Ei Sim Mode, With Helium Carrier Gas And 8 Sequential 10Fg Ofn Splitlers Injection, Monitored For M / Z-272 To Produce Following Idl= 10Fg Or Better • Pumping System: Highly Efficient Turbo Molecular Pump With Minimum Capacity Of 250 Liter / Sec Or Higher To Build Vacuum And To Evacuate System As Soon As Possible ( As Per System Requirement ) • Libraries ( Original ) : Vendor To Quote Following Original, Licensed & Latest Version Of Library / Database With Oem Part / Catalogue Number: Nist 2020 Or Latest , 7. Software: 64 Bit Advanced Chromatographic Integration Software. Software Should Be User Friendly & Simple For Data Handling With Feature Like Easy To Use Report Publisher, Online Help And Answer Wizard, Glp And Fully Compatible With Windows 10. Simultaneous Scan / Sim Mode. Software Should Have Provision For Calculation Of Retention Indices And Retention Time Alignment / Automatic Adjustment Of Retention Time / Retention Time Locking Software With Part Number. All Accessories Like Injectors, Detectors, Gc, Ms, Auto-Sampler, Should Be Controllable From A Single Software Only. ( Complete Controll Of Perameters For Gc ) 13 Additional Consumables A ) Injection Port Septa – 400 Nos. B ) Glass Insert For Split & Splitless ( 10 Nos. Each ) C ) Vespel Ferrule 0.4 Mm – 30 Nos. D ) Vespel Ferrule 0.5 Mm & 0.7 Mm – 10 Nos. Each E ) Graphite Ferule 0.5 Mm – 10 Nos. F ) Graphite Ferule 0.8 Mm – 10 Nos. G ) Manual Syringes - 10 Ul ( 5 Nos. ) H ) Liquid Auto-Sampler Syringes – 10 Nos. I ) Auto-Sampler Vial & Septa - 1000 Nos. J ) Filaments – 6 Nos., Glass Wool – 1 No. K ) Column Cutter – 1 Nos., O-Ring – 50 Nos. L ) Column Nut – 20 Nos., Pump Oil – 5 Liters 14 Utilities: A ) 30-Meter Capillary Columns ( Rxi-5Silms – 2 Nos. Or Equivalent ) , Rtx-200 / 17 – 1 No., Rtx-624 – 1 No. Or Equivalent , B ) Gas Cylinders With Dual Stage Regulators For Helium – 2 Nos. Each C ) Wall Mount Gas Purification And Control System For Gases, Gas Manifold D ) Branded I7 Pc, 8 Gb Ram 1 Tb Hdd, Windows 10 Pro, 32-Bit Ms Office Excel 2016, 21” Monitor And Laserjet Printer E ) 10 Kva Online Ups With 60 Min Back Up For Complete System 15. Accessories For Sample Preparation: • Microprocessor Controlled Ultrasonication Bath With Tank Capacity: Approx. 4 Ltr. Stainless Steel With Digital Timer And Speed With One-Year Warranty • Vortex Mixer Of Reputed Make And N2 Evaporator Of 20-25 Sample Processing Capacity. Warranty: 1 Year • Rotary Evaporator With Vacuum Pump, Vacuum Controller And Chiller • Micropipette- 1Ml To 10Ml, 0.1 Ml To 1.0 Ml, 0.02 Ml To 0.2 Ml, 0.002 Ml To 0.02 Ml • Refrigerated Centrifuge Of Reputed Make With 15 Ml And 50 Ml Rotor. Warranty: 1 Year • Balance With Least Count Accuracy Of 0.1Mg • Refrigerator For Storage Of Crms, Ph Meter, Hot Air Oven • Solvent Filtration Kit With Vacuum Pump And Syringe Filter • Water Purification System Type I & Iii 16. Warranty: Two Years Warranty On Gc-Ms System , Schedule Ii :- Providing, Supplying And Installation Of Various Glasswaress Of Specified Make As Per Following Techincal Conditions, Sepecification And Requirement Complete Within All Respect As Per Direction And To The Entire Sartisfaction Of Engineer- In- Charge.. , Conical Flaskof Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent , 100 Ml , 250 Ml , 500 Ml , 1000 Ml , Beakers Of Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent , 100 Ml , 250 Ml , 500 Ml , 1 Lt , 2 Lt , Pipette ( Without Graduation ) Of Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent , 5 Ml , 10 Ml , 20 Ml , 25 Ml , 50 Ml , 100 Ml , Pipette ( Graduated ) Of Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent , 1 Ml , 5 Ml , 10 Ml , 20 Ml , Burette ( Ordinary ) Of Borosil Make, A Class, Accuracy: ±0.05 Ml, Clear Borosilicate Glass And Stand , 25 Ml , 50 Ml , 100 Ml , Burette ( Automatic ) Of Borosil Make, Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. , 50 Ml. , Desiccators Of Borosil Make, Material: Borosilicate Capacity: 6-5400 Ml Beaker Temperature Resistance: 570 M Ohm , Reagent Bottles Of Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent , 100 Ml. , 250 Ml. , 500Ml. , 1 Ltr , 2 Ltr , Sample Bottles ( Food Grade Plastic ) Of Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent , 250 Ml. , 500 Ml. , 1 Ltr , 2 Ltr , Test Tube Of Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent , Durham Tubes Of Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent , Round Bottom Flask Of Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent. Temperature Resistance-400 Degc, Color-Transparent, Material- Borosilicate Glass 3.3 , 250 Ml. , Measuring Cylinders ( Graduated ) Of Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent , 10 Ml. , 50 Ml. , 100 Ml. , 250 Ml. , 500 Ml. , 1 Ltr , 2 Ltr , Measuring Flask Of Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent , 5 Ml , 10 Ml. , 25 Ml , 50 Ml , 100 Ml. , 250 Ml. , 500 Ml. , 1000 Ml. , Funnels Of Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent , 3 Dia , 4 Dia , 5 Dia , Porcelain Dish Of Borosil Make, Compatible For Analytical Grade Use , Mediun Size, 80 Mm, Glassware Isi Marked / Bis / Equivalent , Big Size, 105 Mm, Glassware Isi Marked / Bis / Equivalent , Crucibles, Compatible For Analytical Grade Use, Isi Marked / Bis / Equivalent, Capacity ( Ml ) : 50Ml, Shape: Circular, Type Of Glassware: Silica , Bucher Funnel Muslin Cloth Dishes, Compatible For Analytical Grade Use , 100 Ml , 500 Ml , 1000 Ml , Stadard Joints Of Borosil Make, Compatible For Analytical Grade Use, Isi Marked / Bis / Equivalent , Grouted , Bends , Glass Roads, Compatible For Analytical Grade Use, Isi Marked / Bis / Equivalent , Glass Beads, Compatible For Analytical Grade Use, Isi Marked / Bis / Equivalent , Nessler Cylinders Of Borosil Make, Should Be Made From Low Expansion Borosilicate I.D. Control Tubing. Individually Calibrated By Automatic Calibration Process. Comes With Highest Quality Standard According To Is 1042. Compatible For Analytical Grade Use. Isi Marked / Bis / Equivalent , 50 Ml. , 100 Ml. , Thermometers Of Npn Make, Compatible For Analytical Grade Use, Isi Marked / Bis / Equivalent , 100°C , 250°C , 500° C , Wash Bottle Of Borosil Make, Should Be As Per The Bis / En / Astm Norms And Should Be Fully Compatible With The Analytical Grade Use For Analytical Instruments. , Separating Flask Of Borosil Make, Should Be As Per The Bis / En / Astm Norms And Should Be Fully Compatible With The Analytical Grade Use For Analytical Instruments. , Bod Bottle, Compatible For Analytical Grade Use, Isi Marked / Bis / Equivalent, Capacity-500 Ml, Usage / Application-Chemical Laboratory, Material: Glass, Isi Marked / Bis / Equivalent , Separatory Funnels, Compatible For Analytical Grade Use, Isi Marked / Bis / Equivalent, Material-Glass, Capacity-1000Ml, Usage / Application-Chemical Laboratory, Stop Cock Bore-Yes, Isi Marked / Bis / Equivalent , Petri Dishes Of Borosil Make, Should Be As Per The Bis / En / Astm Norms And Should Be Fully Compatible With The Analytical Grade Use For Analytical Instruments. , Pressure Vessel ( 50 Ltr Capacity ) Of Borosil Make, Should Be As Per The Bis / En / Astm Norms And Should Be Fully Compatible With The Analytical Grade Use For Analytical Instruments. , Stoppered Bottles For Dissolved Oxygen Of Borosil Make, Should Be As Per The Bis / En / Astm Norms And Should Be Fully Compatible With The Analytical Grade Use For Analytical Instruments. , Schedule Iii :-Providing, Supplying And Installation Of Various Chemicals Must Be Analytical Grade Only, Should Be Supplied With Msds And Safety Certificate As Per Following Techincal Conditions, Sepecification And Requirement Complete Within All Respect As Per Direction And To The Entire Sartisfaction Of Engineer- In- Charge. , Acetic Acid, Glacial, 500 Ml , Alizarin Red S, 500 G , Ascorbic Acid, 100 G , Absolute Alcohol, 500Ml , Aluminium Potassium Sulphate, 500G , Ammonium Acetate, 500G , Ammonium Chloride, 500G , Ammonium Hydroxide, 500G , Ammonium Purpurate / Muroxide, 100G , Arsenis Trioxide, 500G , Barium Chloride, 500G , Bromocresol Green Indicator, 100G , Boric Acid, 500G , Calcium Chloride ( Fused ) , 500G , Calcium Chloride, 500G , Ethylenediaminetetraacitic Acid ( Edta ) , 500G , Erichrome Black T, 10G , Erichrome Cyanine: R, 10G , Ferrous Ammonium Sulphate, 500G , Hydrochloric Acid, 2.5 L , Hydroxylamine Hydrochloride, 500Ml , Hydrogen Peroxide, 500Ml , Electrolytic Iron, 100G , Lead Acetate, 500G , Methyl Orange Indicator / P & R Indicator, 100G , Phenolphthalein Indicator / Methyl Red Indicator, 100G , Potassium Hydroxide, 500G , 1-10, Phenanthroline, Monohydrate, 10G , Potassium Permanaganate, 100G , Potassium Iodide, 500G , Potassium Chromate, 500G , Potassium Hydrogen Phthalate, 500G , Stannous Chloride, 100G , Silver Diethyl-Dithio-Carbamate, 100G , Sodium Hrdroxide, 500G , 4-Aminoantipyrine, 25G , Sodium Acetate, 500G , Sodium Thiosulphate, 500G , Starch ( Soluble ) , 500G , Sodium Fluoride ( Anhydrous ) , 500G , Sodium Arsenate, 100G , Spadns, 100G , Zirconyl Oxycloride, Octohydrate, 100G , Sodium Sulphate ( Anhydrous ) , 500G , Sulphuric Acid ( Sp. Gr.1.84 ) , 2.5 L , Sulphuric Acid Fuming ) Oleum ( If Specifically Required ) , 250G , Sodium Chloride, 500G , Potassium Dicromate, 500G , Calcium Carbonate ( Anhydrous ) , 500G , Phenol, Whte, 500G , Potassium Nintrate, 500G , Sodium Sulphate, 500G , Phindicatorpapre, Range 2-14 With Comparator , Methylated Spirit, 500G , Macconkey Broth, Dehydrated ( Hi-Media ) , 500Ml , Total Ionic Strength Adjustment Buffer ( Tisab ) , 500Ml , Oxalic Acid, 100G , Silver Sulphate, 100G , Aluminium Chloride, 500G , Alkaline Citrate, 50Ml , Ammonium Molybdate, 100G , Nitric Acid , Ammonium Metavanadate, 100G , Anhydrous Potassium Nitrate, 100G , Sulphanilamide, 100G , Sodium Nitrate, 100G , Sodium Oxalate, 100G , Sodium Meta Silicate Nanohydrate, 100G , Sodium Bicarbonate, 100G , Sodium Borate Decahydrate, 100G , Sodium Tetraborate, 100G , Glycerol, 100Ml , Potassium Cloride, 100G , Carmine Reagent, 100G , Ammonium Solution, 100Ml , Mercury Sulfate, 100G , Silver Nitrate, 250G , Sodium Bisulphate, 100G , Sodium Acetate, 500G , Zinc Metal, 100G , Aluminium Hydroxide, 500G , Zincon ( 2-Carboxy-2"-Hydroxy-5"-Sulfoformazyl Benzene ) , 100G , Methanol, 500Ml , Phosphoric Acid, 100Ml , Anhydrous Potassium Bi-Iodate, 100G , Chloroform, 500Ml , Ethyl Ether, 500Ml , Anhyprous Potassium Bromide, 100G , Aluminium Nintrate, 500G , Alkylbenzene Sulfonate ( Las ) Solution, 100Ml , Methylene Blue, 10G , Sodium Phosphate, Monobasic, Monohydrate, 100G , N-Hexane, 100Ml , Petroleum Ether, 100Ml , M-Endo Agar, 500G , M-Fc Agar, 500G , Emb Agar, 500G , Macconkey Agar, 500G , Tcbs Agar, 500G , Xld Agar, 500G , Bismuth Sulphate Agar, 500G , Salmonella Shigella Agar, 500G , Kf Streptococcus Agar , 500G , Mannitol Salt Agar, 500G , Lactose Lauryl Trptose Broth, 500G , Ethyl Alcohol, 500Ml , Rosolic Acid, 100Ml , Bromocresol Purple, 100Ml , Ttc Solution, 100Ml , Brilliant Green Bile Growth, 100Ml , E.C Broth, 100Ml , Luaryl Sulphate Broth, 100Ml , Phosphiric Acid 5% H3p04, 500Ml , Anhydrous Kbr03, 500G , Sodium Arsenite ( Naas02 ) , 500G , Urea, 500G , Antimony Metal, 1G , Choromotropic Acid, 100G , Devard S Alloy, 10G , Borate Buffer, 500Ml , Anhydrous Sodium Sulphate, 500G , Ccl4, 500Ml , Dithiozone Solution, 500Ml , Nh4cns, 500G , Agn03 Anhydrous, 100G , Kh2p04, 500G , Potassium Ferricyanide K3fe ( Cn ) 6, 500G , Azomethane, 500G , Silver Diethyl-Dithiocarbamate Agscsn ( C2h5 ) 2, 500G , Ammonium Or Postassium Sulphate, 250G , 2-3 Diaminonaphtheline ( Dan ) Solution, 500Ml , Hydroxylamine Sulphate, 500G , Sodium Nitroprusside, 500G , Trisodium Citrate, 500G , Phosphate Buffer, 500Ml , Ferroin Indicator, 250Ml , Fire Extinguisher 6.00 Kg , Anhydrous Calcium Carbonate, 500G , Anhydrous Disodium Hydrogen Phosphate, 500G , Borax, 500G , Bromcresol Green Indicator, 5G , Carmine Stain, 25G , Chloramine T Solution 500 G , Chloroform, 2.5L , Cobalt Chloride, 500G , Crm Aluminium From Nist Al ( No3 ) 3 In Hno3 0.5 Mol / L 1000 Mg / L Al 500Ml, , Crm Antimonyfrom Nist Sb2o3 In Hcl 2 Mol / L 1000 Mg / L Sb 500Ml, , Crm Arsenic 250Ml , Crm Barium 250 Ml , Crm Cadmium From Nist Cd ( No3 ) 2 In Hno3 0, 5 Mol / L 1000 Mg / L Cd 500Ml , Crm Copper From Nist Cu ( No3 ) 2 In Hno3 0, 5 Mol / L 1000 Mg / L Cu 500Ml , Crm Leadfrom Nist Pb ( No3 ) 2 In Hno3 0.5 Mol / L 1000 Mg / L Pb 500Ml, , Crm Mercuri , Crm Molebdenumfrom Nist ( Nh4 ) 6Mo7o24 In H2o 1000Mg / I Mo 100Ml , Crm Nickel From Nist Seo2 In Hno3 0, 5 Mol / L 1000 Mg / L Se 100Ml , Crm Selinium From Nist Seo2 In Hno3 0, 5 Mol / L 1000 Mg / L Se 500Ml , Crm Silverfrom Nist Agno3 In Hno3 0, 5 Mol / L 1000 Mg / L Ag 500Ml , Crm Total Chromium From Nist Cr ( No3 ) 3 In Hno3 0, 5 Mol / L 1000 Mg / L Cr 500Ml, , Crm Zinc From Nist Zn ( No3 ) 2 In Hno3 0, 5 Mol / L 1000 Mg / L Zn 500Ml , Diatomaceous Silica Filter Aid Suspension , Dichloromethane, 2.5L , Diisopropyl Ether 500Ml , Dipotassium Hydrogen Phosphate, 500G , Disodium Hydrogen Phosphate, 500G , Ferric Chloride , Ferric Sulphate, 500G , Glacial Acetic Acid Ar, 500Ml , Glucose, 500G , Hexa Methylene Tetramine, 500G , Hydrazine Sulphate, 500G , Hydrochloric Acid, 2.5L , Hydrofluoric Acid, 500Ml , Lead Carboante, 500G , L-Glutamic Acid, 100G , M002-500G-Nutrient Broth , M043-500G-Baired -Parker Agar , M052-500G-Selenite F Broth , M121i-500G-Brilliant Green Agar , M189-500G-Thiosulphate- Citrate Bile Salt Sucrose Agar ( Tcbs ) , M1991i-100G-Chromogenic Coliform Agar , M612-500G-Slantez And Bartlety Medium , M614-500G-Buffered Peptone Water , M618-500G-Alkaline Peptone Water , M739-500G-Bile Salt Agar , Magnesium Chloride, 500G , Magnesium Salt Of Edta, 500G , Magnesium Sulphate Ar, 500G , Manganous Sulphate, 500G , Mercuric Sulphate, 100G , Mercury Chloride, 100G , Metacresol Purple Indicator, 5G , Di-Potassium Phosphate, 500G , Tert Butyl Methyl Ether, 500Ml , 1-2 Dibromopropane, 100G , 2- Propanol, 500Ml , 2, 4- Dichlorophenylacetic Acid, 25G , 2, 4, 6- Trichlorophenol, 500G , 4, 4- Dibromooctafluorobiphenyl, 1G , Acetone, 500Ml , Acetonitrile Hplc Grade, 1L , Anhydruous Sodium Carbonate , Bromodichloromethane 500Ml , Bromoform Ar, 250Ml , Carbazole, 100G , Carbitol ( Diethyl Glycol Monoethyl Ether ) , 1L , Cupric Sulphate Ar, 500G , Cyclohexane Ar, 500Ml , Decachlorobiphenyl, 100Mg , Dftpp Standards, 100Mg , Diazide 25G , Dibromochloromethane , Dodecylbenzene Sulphuric Acid Methyl Esther , Ethanolic Sodium Hydroxide 500G , Ethyl Acetate Ar, 500Ml , Diethyl Ether Ar, 500Ml , Extraction Solvent ( Pentane / Hexane ) , Florisil, 100G , Helium Gas Carrior , Hydrochloric Acid Ar, 500Ml , Isooctanol ( 2-Ethyl Hexan-1-Ol ) , 500Ml , Mercuric Chloride, 25G , Methyl Alcohol 500 Ml , Tert Butyl Methyl Ether Ar, 500Ml , Methylene Chloride ( Dichloromethane ) , 500Ml , Monuron, 100Mg , Pentachloronitrobenzene, 25Mg , Phenophthalein Indicator, 125Ml , Phosphoric Acid Ar, 500Ml , Potassioum Hydroxide Ar, 500G , Potassium Phosphate Ar, 500G , Silica Gel, 500G , Silicic Acid, 250G , Sodium Thiiosulphate Ar, 500G , Sodium Dihydrogen Carbonate Ar, 500G , Sodium Hydroxide Ar, 500G , Sodium Thiosulphate Ar, 500G , Toulene Ar, 500Ml , Trimethylesilyldiazomethane 25Ml , Triochloroethane, 500G , Tris Hcl, 500G , Tris Hydroxy Methyleamino Methane, 500G , Argon ( Commercial Grade ) 5Ltr , Ammonium Acetate Buffer, 1Kg
|