Tender For Extension Of First Floord& E Building At Be -Hyd- Civil Works: 2 Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. 3 Removal Of Surkhi Of Any Thickness By Manual Stock Mechanical Meanson The Terrace And Disposing The Debries Upto 50M Lead Etc Complete 4 Demolishing R.C.C. Work Manually / By Mechanical Means Including Tacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge. 5 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar 6 Disposal Of Moorum / Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Material By Mechanical Transport Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground For Lead Upto 10 Km For All Lifts, Complete As Per Directions Of Engineer-In-Charge. 7 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area 3 Sq. Metres And Below 8 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge All Works Above Plinth Level Upto Floor V Level 9 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts 10 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 11 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform 12 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Weather Shade, Chajjas, Corbels Etc., Including Edges 13 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards 14 Steel Reinforcement Of Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete. The Work Shall Be Executed As Per The Darwing Including All Heights. ( Note: The Basic Rate For Steel To Be Considered Is Rs55 Kg ) 15 Providing And Fixing 8 Mm Rebar With Re-500 V 3 Chemical Etc. Including Drilling Hole As Required And Embedment Length As Per Specification Complete In All Repect As Per The Directions Of The Engineer Incharge :8 Mm Dia 16 Providing And Fixing 10 Mm Rebar With Re-500 V 3 Chemical Etc. Including Drilling Hole As Required And Embedment Length As Per Specification Complete In All Repect As Per The Directions Of The Engineer Incharge :10 Mm Dia 17 Providing And Fixing 12 Mm Rebar With Re-500 V 3 Chemical Etc. Including Drilling Hole As Required And Embedment Length As Per Specification Complete In All Repect As Per The Directions Of The Engineer Incharge :12 Mm Dia 18 Providing And Fixing16 Mm Rebar With Re-500 V 3 Chemical Etc. Including Drilling Hole As Required And Embedment Length As Per Specification Complete In All Repect As Per The Directions Of The Engineer Incharge :16 Mm Dia 19 Providing And Fixing 20 Mm Rebar With Re-500 V 3 Chemical Etc. Including Drilling Hole As Required And Embedment Length As Per Specification Complete In All Repect As Per The Directions Of The Engineer Incharge :20 Mm Dia 20 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 5 In Superstructure Above Plinth Level Up To Floor V Level In Ll Shapes And Sizes In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 21 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 22 12 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 23 6 Mm Cement Plaster Of Mix :1:3 ( 1 Cement : 3 Fine Sand ) 24 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) 25 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade With A Coat Of Primer :Two Or More Coats On New Work 26 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 27 Providing And Painting Two Or More Coats On New Work With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade 28 Providing Sal Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) 29 Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 30X10x15cm 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size ) . 30 Providing And Fixing 35 Mm Thick Flush Door Confirming Is: 2202 ( Part-1 ) Core Of Solid Wood, Construction With Frame Of Pine Wood With Density Of 700 Kg / M3 With 5 Ply Construction With 1Mm Hpl Sheet ( Laminate ) On Both Sides And Laminate Pre Pressed From Factory, Confirming Is 2046 With Bwp Grade Adhesive Treatment With Phenol Formaldehyde Resin As Per Is 848 Norms Ensures Superior Quality And Performance Of The Doors With Uniform Thickness Without Undulation, Wraping Or Bending. Emission Free As Per E1 Standard And Eco-Friendly Fixed To The Existing Frames Including Providing Internal Lipping With Second Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Shutter With 4 Nos.Of 125Mm Long Ss Hinges For One Shutter Etc., Complete. ( Note: The Shutters Shall Be Provided With Vision Pannel As Per Drawing. In Case Of Double Leaved Shutters Rebating Shall Be Made Without Any Extra Cost ) 31 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of22 Dia X 200Mm, Godrej Code No 7261 Or Approved Quality & Make With Necessary Screws Etc All Complete. 32 Providing And Fixing Stainless Steel ( 304 Grade ) Satin Finishtower Bolt 300 Mm Long Of Godrej Make ( Product Code - 8570 ) Or Equivalent With Necessary Screws Etc., Complete 33 Providing And Fixing Stainless Steel ( 304 Grade ) Satin Finish Door Stopper 90 Mm Longof Godrej Make ( Product Code - 8565 ) Or Equivalent With Necessary Screws Etc., Complete 34 Providing And Fixing Standard Approved Quality Hydraulic Door Closers Suitable For Doorsof Dorma Make With Necessary Fixtures, Screws Etc. Complete. 35 Providing And Fixing Bright Finished Inside Opening Brass Mortice Lock With 6 Levers Of Godrej Make Or Equivalent With Necessary Screws Etc., Complete 36 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coatwith Approved Steel Primer All Complete Fixed To Steel Windows By Welding 37 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portion Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 38 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 39 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is: 12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineerin- Charge. Pre-Laminated Particle Board With Decorative Laminationn On Both Sides 40 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 4.0 Mm Thickness ( Weight Not Less Than 10Kg / Sqm ) 41 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 5.50 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) 42 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Granite Of Any Colour And Shade Area Of Slab Upto 0.50 Sqm 43 Providing And Laying Vitrified Tiles In Floor With Different Sizes ( Thickness To Be Specified By The Manufacturer ) , With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive ( Water Based ) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints ( Payment For Grouting Of Joints To Be Made Separately ) .Size Of Tile 600X600 Mm ( Basic Price Of Vitrified Tile Is Rs 660.00 Per Sqm 44 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) , With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, In Skirting, Riser Of Steps, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive ( Water Based ) Conforming To Is: 15477, In Average 6 Mm Thickness, Including Grouting Of Joints ( Payment For Grouting Of Joints To Be Made Separately ) .Size Of Tile 600X600 Mm 45 Supply And Laying Of Electrostatic Dissipative Type Flexible Homogenous Compressed Esd Vinyl Floor Tiles Of Minimum Size 610 Mm X 610 Mm X 2 Mm Of M / S Forbo Make. Necessary Preparation Of Sub Floor Surface Should Be Bel - Quotation For The Esd Flooring-Reg Done Using Self-Leveling Compound. The Flooring Should Be Laid Using Approved Conductive Adhesives. Joint Between The Tiles Shall Be Grooved, Pvc Welded Using Automatic Equipment And Copper Tape Shall Be Provided And Laid All As Per Manufacturer’S Specification. The Tiles Will Have Permanent Conductivity And Esd Properties To Be Independent Of Humidity Due To Homogenous Nature Of Product As It Is Sliced From Pressed Vinyl Block. Scope Of Work Should Include Laying Of Tiles, Self Levelling Compound, Conductive Adhesive, Copper Tape At Site, Grooving / Welding Of Joints As Per Manufacturers Specifications. Certification Of Electrical Resistance Such As Point To Point, Point To Ground And Body To Ground Resistance, Combination Resistance Of The Installed System And Body Voltage Generation, Meeting To International Standards And Duly Tested And Authorized By A Certified Esd Engineer Who Has Received His Certificate From An Internationally Reputed Certifying Organization. ( Note: Rate To Be Quoted For Complete Finished Work Including All Materials And Labour And Necessary Preparation Of Surface. 46 Providing And Fixing In False Ceilingat All Height With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595 Mm Of Approved Texture, Design And Patterns Having Nrc ( Noise Reduction Coefficient ) Of 0.50 ( Minimum ) As Per Is 8225:1987, Light Reflecting Of 85% ( Minimum ) .Non Combustible As Per Bs:476 ( Part-4 ) , Fireperformance As Per Bs:476 ( Part 6 &7 ) , Humidity Resistance Of 100%, Thermal Conductivity <0.043W / M K As Per Astm / 518:1991, In True Horizontal Level Suspended On Interlocking Metal Coated T-Grid Of Hot Dipped Galvanised Iron Section Of 0.40 Mm Thick On Silhouette Profile, Rotatory Stiched Double Webbed White With 6 Mm Reveal Profile ( White / Black ) , Comprising Of Main-T Runners Of Size 15X42 Mm Of Length 3000 Mm, Cross -T Of Size 15X42 Mm Of Length 600Mm To Form Grid Module Of Size 600X600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items ( Galvanizing @80 Grams Per Sqm ) I.E 50 Mm Long, 8Mm Outer Diameter M-6 Dash Fasteners , 4Mm Thick G I Hanger, With 15 Mm Thick Integral Densified Micro Edge Light Weight Calcium Silicate False Ceiling Tiles. 47 Providing And Fixing Seamless Ceiling With Gpboard Of 12.5Mm Thick , Fixed To The Underside Of The Suspended Grid Formed Of Gi Perimeter Channel Of Size 20X27x30 Mm ( Mf 6A ) Fixed Along The Wall By Using Wood Screws And Metal Expansion Rawl Plugs. The Gi Intermediate Channel Of Size 45X15x0.90 Mm ( Mf7 ) Shall Be Fixed To The Suspended Strap Hangers / Gi Angle / Starp Hanger Is To Be Connecte With Gi Soffit Cleat Of Size 37X27x25x1.6 Mm And It Should Be Fixed On The Roof Slab / Beam, By Using Metal Expansion Fasteners ( Wt. Type ) Of 12.5 Mm Dia. To A Length Of 35 Mm With 6 Mm Dia Bolt / Screw At Top Ends. The Gi Ceiling Section Of Size 80X26x0.5 Mm ( Mf 5 ) Is To Be Provided Across The Intermediate Channel At Intervals Not More Than 610 Mm Centre At Bottom And The Same Shall Be Fixed By Gi Connection Clips 2.64 Mm Dia At The Intersection Points . The Ends Of Ceiling Section ( Mf 5 ) Channel By Adopting An Overlap Length Of Minimum 150 Mm, Shall Be Connected With Intermediate Channel Perimeter Channel In Insertion The Gypboard Shall Be Fixed To The Under Side Of The Suspended Grid By Using 25 Mm Long Dry Wall Screws. The Joints Shall Be Finished With Joint Paper / Fibre Mesh Lape By Using Jointing Compound Of Saint-Gobain Ltd., And Applying Over It 3 Layers Of The Filer Compound To Provide A Smooth Surface. The Rate Shall Include Making Cutouts For Tube Lights, Spot Light , Duct Doors, For Specified Size, Grills Etc., For Which No Extra Wil Be Paid Separately. Rate Shall Include Providing Additionaltrimming Around Cutouts For Light Fittings Grills And Also For Providing Additional Supports From Ceiling Wheremain / Cross Members Are Cut For Light Fittings Etc. This False Ceiling Shall Be Provided In Combination Of 600X600 Calcium Silicate False Ceiling And Will Be Measured Under Respective Item. 48 52 Mm Thick Cement Concrete Flooring With Concrete Hardener Topping, Under Layer 40 Mm Thick Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) And Top Layer 12 Mm Thick Cement Hardener Consisting Of Mix 1:2 ( 1 Cement Hardener Mix : 2 Graded Stone Aggregate 6 Mm Nominal Size ) By Volume, Hardening Compound Mixed @ 2 Litre Per 50 Kg Of Cement Or As Per Manufacturer"S Specifications. This Includes Cost Of Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 49 Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: ( A ) Applying A Slurry Coat Of Neat Cement Using 2.75 Kg / Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is. 2645 And Approved By Engineer-In-Charge Over The Rccslab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. ( B ) Laying Brick Bats With Mortar Using Broken Bricks / Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 ( 1 Cement : 5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 ( 1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs. ( C ) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg / Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge. ( D ) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 ( 1 Cement :4 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. ( E ) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.“All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. 50 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 110 Mm Diameter 51 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion Shoe ( Plain ) 110 Mm Shoe 52 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion Bend 87.5° 110 Mm Bend 53 Providing And Fixing Luxaflex Make 100 Mm Wide Vertical Blinds Made Out Of 100 Mm Non-Woven Fabric. The Fabric Shall Be Scotch Guard Protected, Antistatic And Shall Be Sanitized To Resist Fungal Growth. The Head Channel Shall Be Of 33 Mm Wide And 30 Mm Deep With A Minimum Valve Thickness Of 1.2 Mm Extruded From 6063-T5 Aluminium Alloy Finished In Clear Anodising To A Thickness Of 10 Microns ( Note: Height Of The Blind Will Be Measured From Top Of The Head Rail To Bottom Of Slat. Length Of The Head Rail Shall Be Measured To The Length Of The Blind ) Etc., Complete. 54 Electrical Works: 55 Supplying Of Lt Power Cable With Aluminium Conductor, Xlpe / Pvc Insulated, Pvc Inner Sheathed, Armoured, 1.1Kv Grade, Confirming To Is:1554 ( Part-1 ) , Is:7098 ( Part-1 ) & Relevant Standards Having 3.5 Core Of Size 150 Sq Mm 56 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Above 95 Sq. Mm And Upto 185 Sq. Mm Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. 57 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For 3½ X 150 Sq. Mm ( 50Mm ) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 58 Design, Fabrication, Supply, Erection, Testing And Commissioning Of Duly Wired 415Volts, 50Hz, 3Phase, 4Wire Electrical Main Distribution Board ( Mdb ) Having I / C& O / G Feeders, Instrumentation Metering, Protection System, Aluminium Busbars & Other Components Completely As Per Single Line Diagram And As Per Detailed Technical Specifications. The Panel Shall Be Of Modular Type, Floor Mounting, Free Standing, Vermin Proof, Ip-43 Grade, Made Out Of Crca Sheet Steel Of 1.6Mm Thickness For Body & 2Mm For Load Bearing Points, Powder Coated Painting, Fuseless Type Confirming To Relevent Is Standards. The Panel Shall Have Microprocessor Based Mccb With Shunt Tripp For Incomer And Thermal Magnetic Based Mccbs For Out Going Feeders With Rotory Handle. The Work Includes Providing Required Fixing Accessories Such As Grouting Bolt-Nuts, Welding, Coupling Of Laid Conduits / Cables And Associated Civil Works Complete As Directed. ( Note:- Please Refer Drawing And Dts For Mdb Details ) 59 Supplying Of Lt Power Cable With Copper Conductor, Xlpe / Pvc Insulated, Pvc Inner Sheathed, Armoured, 1.1Kv Grade, Confirming To Is:1554 ( Part-1 ) , Is:7098 ( Part-1 ) & Relevant Standards Having 4 Core Of Size 16 Sq Mm 60 Supplying Of Lt Power Cable With Copper Conductor, Xlpe / Pvc Insulated, Pvc Inner Sheathed, Armoured, 1.1Kv Grade, Confirming To Is:1554 ( Part-1 ) , Is:7098 ( Part-1 ) & Relevant Standards Having 4 Core Of Size 10 Sq Mm 61 Supplying Of Lt Power Cable With Aluminium Conductor, Xlpe / Pvc Insulated, Pvc Inner Sheathed, Armoured, 1.1Kv Grade, Confirming To Is:1554 ( Part-1 ) , Is:7098 ( Part-1 ) & Relevant Standards Having 3.5 Core Of Size 50 Sq Mm 62 Supplying Of Lt Power Cable With Copper Conductor, Xlpe / Pvc Insulated, Pvc Inner Sheathed, Armoured, 1.1Kv Grade, Confirming To Is:1554 ( Part-1 ) , Is:7098 ( Part-1 ) & Relevant Standards Having 3 Core Of Size 10 Sq Mm 63 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. 64 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) Size On Cable Tray As Required. 65 Supplying And Fixing Of 6 Way ( 8+18 ) , Vtpn, ( Ip 43 ) , Metal Door, Sheet Steel, Mccb Distribution Board, 240 / 415 V, On Surface / Flush, Complete With Tinned Copper Bus Bar Of 250A, 2 Neutral Bus Bar, 2 Earthbar, Din Bar, Interconnections, Powder Painted Including Earthing And With Provison Formccb"Sas Incomer And Sp / Tp Mcb"S As Outgoing. Ref:- Legrand -5077 46 66 Supplying And Fixing Of 12 Way , Double Door, ( Single Pole And Neutral ) , Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earthbar, Din Bar, Interconnections, Powder Painted Includingearthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) . 67 Supplying And Fixing Of6 Way ( 4 + 18 ) , Double Door , Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) . 68 Providing And Fixing Of 125A, 16Ka Of Breaking Capacity And Tpn Mccbwith Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. Ref:- Legrand -4200 06 69 Providing And Fixing Of 63A, 16Ka Of Breaking Capacity And Tpn Mccbwith Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. Ref:- Legrand -4200 00 To 4200 05 70 Providing And Fixing Of 100A, 16Ka Of Breaking Capacity And Tpn Mccbwith Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. Ref:- Legrand -4200 00 To 4200 05 71 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, "C" Curve, Double Pole, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete Withconnections, Testing And Commissioning Etc. As Required. 72 Supplying And Fixing Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required & As Per Sld. 73 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, "C" Curve, Triple Pole And Neutral Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete Withconnections, Testing And Commissioning Etc. As Required. 74 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, "C" Curve, Single Pole, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete Withconnections, Testing And Commissioning Etc. As Required. 75 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, "C" Curve, Triple Pole, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete Withconnections, Testing And Commissioning Etc. As Required. 76 Supplying And Fixing Of20 Mmsize Of Steel Conduit On The Wall / Column / Ceiling / Truss As The Case May Be Along With Accessoriesas Surface / Recess System Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit Including Associated Civil Works As Required. 77 Supplying And Fixing Of25 Mmsize Of Steel Conduit On The Wall / Column / Ceiling / Truss As The Case May Be Along With Accessoriesas Surface / Recess System Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit Including Associated Civil Works As Required. 78 Supplying And Fixing Of 20 Mm Size Of Medium Class Pvc Conduit Along With Accessories On The Wall / Column / Ceiling / Truss As Surface / Recess System Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit Including Associated Civil Works As Required. 79 Supplying And Fixing Of 25 Mm Size Of Medium Class Pvc Conduit Along With Accessories On The Wall / Column / Ceiling / Truss As Surface / Recess System Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduitwith Associated Civil Works As Required. 80 Supplying And Drawing / Wiring Of 3 X 1.5 Sq.Mm Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 81 Supplying And Drawing / Wiring Of 3 X 2.5 Sq.Mm Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 82 Supplying And Drawing / Wiring Of 3 X 4 Sq.Mm Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 83 Supplying And Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Including Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group-C 84 Supplying And Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group-C 85 Supplying Of Below Mentioned Specification Led Luminaire & Fixing Of The Same In The Ceiling By Providing Required Down Rod / Chain, Clamps Screws / Anchor Bolt-Nuts, Washers Etc., Making Electrical Connections, Earthing Etc., As Required / Directed By Engineer-In-Charge. Mounting Type :- Recesstype :- 2Ft*2Ft Luminairesystem Lumens :- Not Less Than 3600 Lumensluminous Efficacy :- Not Less Than 100 Lumens / Wattinput Power :- Consuming Not More Than 36Wcolor Temperature :-Not Less Than 5700Khousing :- Pressure Die Cast Alluminium / Crcadiffuser :- Specially Frosted Polycarbonate Diffuserdriver :- Electronicref Model :-Wipro Enterprises :- Elate Led - Crco10r038hp57gl1 Or Equivalent In Approved Makes 86 Supplying Of Below Mentioned Specification Led Luminaire & Fixing Of The Same In The Ceiling By Providing Required, Clamps Screws / Anchor Bolt-Nuts, Washers Etc., Making Electrical Connections, Earthing Etc., As Required / Directed By Engineer-In-Chargetype :- Ip-65, Wetherproof, Industrial Type Linear Led Tube Light Luminaire With Capsule.Mounting Type: Surface Mounting Type. System Lumens :- Not Less Than 1800 Lumensrated Power :- Not More Than 20Wcolor Temperature :-Not Less Than 6000Khousing :- Extruded Powder Coated Aluminium / Polycorbonate Housing.Diffuser :- Polycorbonate Diffuser Coverdriver :- In Built Electronic Driver .Ref Model :- Similar To Wipro : Wio831208g1 Or Equivalent Approved Makes. 87 Supplying Of Below Mentioned Specification Led Luminaire & Fixing Of The Same In The Ceiling By Providing Required, Clamps Screws / Anchor Bolt-Nuts, Washers Etc., Making Electrical Connections, Earthing Etc., As Required / Directed By Engineer-In-Chargemounting Type :- Surface Mountingtype :- Round Down Light Luminaire.System Lumens :- Not Less Than 1800 Lumensrated Power :- Not More Than 18Wcolor Temperature :-Not Less Than 6000Khousing :- Powder Coated Pressure Die Cast Alluminium & Bottom Frame.Diffuser :- High Efficiency, Non Yellowing Pmma Diffuser.Driver :- Electronic Driver.Ref Model :- Wipro: Ld06-221Xxx-57Smg1 Or Equivalent In Approved Makes List. 88 Supplying And Fixing Ofmodular 5A / 6A Switch On The Existing Modular Plate & Switch Box Including Making Electricalconnections But Excluding Modular Plate Etc. As Required. 89 Supplying And Fixing Of Modular 15A / 16A Sp Switch On The Existing Modular Plate & Switch Box Including Making Electricalconnections But Excluding Modular Plate Etc. As Required. 90 Supplying And Fixing Of Modular3pin 5A / 6A Socket Outleton The Existing Modular Plate & Switch Box Including Making Electricalconnections But Excluding Modular Plate Etc. As Required. 91 Supplying And Fixing Of Modular 6Pin 15A / 16A Socket Outlet On The Existing Modular Plate & Switch Box Including Making Electricalconnections But Excluding Modular Plate Etc. As Required. 92 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 93 Supplying & Fixingof2 Timer Acdb Comprising Of 7X24hrs Microcontroller Based Programmable 2 Change Over Time Switch ( Digital, Daily / Weekly Program, 6 Years Reserve, 230Vac With Lethium Cell ) , 25A 3Pole Power Contactor, Terminal Blocks, Wire Etc., For Automatic Switching "On & Off" Of The 3Nos Ac Systems Alternatively 2Nos Ac Units At A Time For 8Hrs, The Switchgears Shall Be Completly Housed / Mounted In Suitable Size Indoor Duty Non Metallic / Crca Box And Installation Of The Same Recessed / Partly Recessed In Wall By Providing Fixing Accessories Such As Bolt-Nuts, Clamps, Screws, Welding Etc., Coupling Of The Laid Conduits / Cables, Making Electrical Connections Etc., Including Associated Civil Works Complete As Directed. ( Ref Make For Time Switch: Schneider Time Switch ( Cct15720 ) Or Equivalent In Approved Make ) ( Please Refer Our Electrical Drawings & Dts For Details ) . 94 Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A "C" Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 95 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For3½ X 50 Sq. Mm ( 35Mm ) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 96 Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For 4 X 10 Sq. Mm Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 97 Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For 4 X 16 Sq. Mm Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 98 Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For 3 X 10 Sq. Mm Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 99 Supplying And Fixing Of 4 Way ( 8+12 ) , Vtpn, ( Ip 30 ) , Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Flush, Complete With Tinned Copper Bus Bar Of 250A, 2 Neutral Bus Bar, 2 Earthbar, Din Bar, Interconnections, Powder Painted Including Earthing And With Provison Formccb"Sas Incomer And Sp / Tp Mcb"S As Outgoing. 100 Supplying And Fixing Of1 Or 2 ( 75Mm X 75Mm ) Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recessincluding Associated Civil Works Etc., As Required. 101 Supplying And Fixing Of 4 Module ( 100Mm X 75Mm ) , Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recessincluding Associated Civil Works Etc., As Required. 102 Supplying And Fixingof6 Module ( 200Mm X 75Mm ) Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recessincluding Associated Civil Works Etc., As Required. 103 Supplying And Fixing Of 12 Module ( 200Mm X 150Mm ) Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recessincluding Associated Civil Works Etc., As Required. 104 Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) 105 Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm ) 106 Supplying And Installing300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required. 107 Supplying And Installing300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Hot Dipped Galvanised Iron Cable Tray "Bends" ( Galvanisation Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc.As Required. 108 Supplying And Installing 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Hot Dipped Galvanised Iron Cable Tray "Tee" ( Galvanisation Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required. 109 Supplying Of All The Required Materials Of Approved Make To Construct A Maintenance Free Chemical Earthing System As Per Drawing & Detailed Specification. Each Set Of Earthing Pit Shall Consists Of A Copper Bonded Solid Steel Rod Electrode Of 14.0Mm Dia X 3.0Mtr Length With Required Quantity Of Nontoxic Electrically Conductive Concrete / Backfill Compound, Copper / Brass Termination Busbar & Bolt-Nuts, Washers Etc. The Work Includes Drilling / Making A Hole Of 150Mm Dia In The Ground To Required Depth By Manual Or Mechanized Method, Keeping The Electrode In The Centre Of The Pit, Filling The Already Prepared Semi Solid Paste / Slurry Of Backfill Concrete / Compound Fully & Curing, All The Civil Works Such As Excavation, Refilling, Construction Of Brick Chamber, Rcc Cover, Curring Etc. The Complete Work Shall Be Carried Out As Per Our Drawing And Manufacturers Instructions / Mannuals Or As Per Standard. Note: The Earth Enhancing Compound / Concrete Shall Be Of Low Resistivity Conforming To Iec 62561-7 Standard. ( Makes: Obo / Erico / Loress / Indelec / Jmv / Lpi / Ashlok ) 110 Supplying & Fixing Of Ip-44 Grade Non Metalic Distribution Box Having 32A, 3Pole+N+Earth Insulated Plug & Socket ( With Plug Top ) , 32Atpn Mcb ( 10Ka, C-Curve ) Along With Accessories And Fixing Of The Same As On The Wall Orflush With Wall As Required Coupling Of The Condiuts, Making Electrical Connections, Earthing Etc., As Directed ( Ref Make:Legrand:0566 53 ) Or Equivalent From Approved Makes. 111 Supplying & Fixing Of Ip-65 Grade Non Metalic Distribution Box Having 32A, 3Pole+N+Earth Insulated Plug & Socket ( With Plug Top ) , 32Atpn Mcb ( 10Ka, C-Curve ) Along With Accessories And Fixing Of The Same As On The Wall Orflush With Wall As Required Coupling Of The Condiuts, Making Electrical Connections, Earthing Etc., As Directed ( Ref Make: Legrand:0566 73 ) Or Equivalent From Approved Makes. 112 Supplying, Installation, Testing And Commissioning Of Passive Infrared ( Pir ) Technology Based Occupancy Sensor With Day Light Dimming ( Lighting Level Shall Be Regulated As Per Availability Of Natural Day Light In An Area Along With Occupancy Detection. ) Having High Preformance, Regulating Programmable Type, Suitable For Connected Load Upto 10Amp , For Mounting Height Up To 2.8 Mtr And For 5 M Diameter Coverage Area Along With Necessary Fixing Arrangements I / C Programming At Site Etc. Complete As Required. 113 Fas & Pas 114 Supply, Installation, Testing And Commissioning Of Microprocessor Controlled Four / Five Loop Analogue Addressable Main Fire Alarm Control Panel With Five ( 5 ) Loop Cards, Alarm Facilities, Hooter, Fire / Fault Indications, Audio Visual Signals, Batterycharger, Facility To Connect Printer Through Extra Rs485 Module And Public Address System Interface System Software.Make: Morley 115 Supply, Installation, Testing And Commissioning Of Addressable Uniform Flat Response / Multi Sensor Type Smoke Sensor With Base.Make: Morley-Ias 116 Supply, Installation, Testing And Commissioning Of Addressable Manual Call Point / Station With Modules.Make: Morley-Ias 117 Supply, Installation, Testing And Commissioning Of Response Indicator.Make: Locally Manufactured 118 Supply, Erection, Testing And Commissioning Of Addressable Wall / Ceiling Loop Sounder / Hooter.Make: Morley-Ias 119 Supply, Installation, Testing And Commissioning Of 2C X 1.5 Sq.Mm Pvc Armoured Frls Copper Cable Including Juction Boxes All As Specified And / Or Directed Etc., Complete. 120 Supplying Of Single Sided Exit Signage Led Light Of Red / Green Colour As Required At Site With Built In Battery Backup For 2 Hrsand Fixing Of The Same On The Rcc / False Ceiling By Providing Required Clamps / Downrods / Bolt-Nuts / Screws, Making Electrical Connections Etc., As Required / Directed By Engineer-In-Charge. Please Refer Fire Alarm System Drawing For Locations. ( Make Similar To Bajaj Or Equivalent In Other Makes ) 121 Supply, Erection, Testing And Commissioning Of 6W Ceiling Mounted Speakers With Builtin 100 V Line Transformers And Different Power Tapping All Asspecified And / Or Directedetc., Complete. 122 Supply, Erection, Testing And Commissioning Of 6W Wall Mounted Speakers With Builtin 100 V Line Transformers And Different Power Tapping All Asspecified And / Or Directedetc., Complete. 123 Supply, Erection, Testing And Commissioning Of Volume Control Switch All As Specifiedand / Ordirectedetc., Complete. 124 Supply And Laying Of 2 Core ( 24 / 0.2 ) Copper Wire Pvc Insulated Twisted And Shielded Unarmoured Wire For Speakers / Volume Control Switch Of Public Address System Suitable For Laying In Pvc Conduit All As Specified And / Or Required Etc Complete., 125 Supply And Fixing 19 Mm Dia 2 Mm Thick Pvc Conduit Along With All Accessories Likebends, Elbows, Jbs, Tees., In Surface / Recess Including Chipping The Wall Making Good The Same In Case Of Recessed Conduit All As Specified And / Or Required And Directed. 126 Supply, Erection, Testing And Commissioning Of Zone Selector Of Capacity Not Less Than 4 Zone With Console With A Mic For Pa System. 127 Network And Communication 128 Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required..23 Awg Solid Bare Copper , Flame Retardant Pvc Jacket, In A Box Of 305M, And Iso / Iec 11801Iec61156•5 Complaint Make: Comscope / Panduit-Pannet / Dlink / Belden 129 Supplying And Laying Of Following Size Of Hdpe Pipe 63Mm Od .Lsi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc. In The Existing Trench, Complete As Required. 63 Mm Hdpe Pipe In Duct / Trench As Directed By Engineer Incharge .Make:Prime / Reliance / Apollo / Rishi 130 Supplying And Fixing Of Following Sizes Of Medium Class 25 Mm Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.E.Make: Universal / Supreme / Classic 131 Supplying And Fixing Of Following Sizes Of Medium Class 50 Mm Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.Make: Universal / Supreme / Classic 132 Supplying, Installation, Termination, Labling & Testing Of Dual ( 2 ) Port Flush Type Face Plate With Back Box.Cat6.Make: Comscope / Panduit-Pannet / Dlink / Belden 133 Supplying, Installation, Termination, Labling& Testing Of Rj-45 Modular Jacks, Complaint With Isollec11801 Nsi / Tia / Eia-568, Should Accept Solid 22-24 Awg Diameter Conductors With Certified For Ul94v-0 Rated, Series Connecting Hardware Standards .Cat6 ( Green Or Yellow ) . Make: Comscope / Panduit-Pannet / Dlink / Belden 134 Supplying, Installation, Termination, Testing, Commissioning And Labling Of 24-Port Patch Panel, Utp Category 6, Tia / Eia 568-6.2, With Min1000 Mating Cycles, Metal Rear Cable Manager To Properly Guide Cables To Point Of Termination And Come With Velcro Straps For Tying The Cables, Modular Connector Should Be Fcc Part68, Subpart F And Iec-60603-7 Allows For 568 A / B Wiring Configuration And Idc Body & Cover Material Fire - Retardant Make: Comscope / Panduit-Pannet / Dlink / Belden 135 Supplying, Laying, Labling& Testing Of Utp Category 6 Patch Cords 2 Mtrs, Tia / Eia 568-8.2 , With Lsoh - Low Smoke Zero Halogen Free. And 1000 Mating Cycles, Rj 45 Plug Should Be Of Polycarbonate Fcc Part 68 Subpart F, Ul 94V-0Make: Comscope / Panduit-Pannet / Dlink / Belden 136 Supplying, Laying, Labling& Testing Of Utp Category 6 Patch Cords 1 Mtrs, Tia / Eia 568-8.2 , With Lsoh - Low Smoke Zero Halogen Free. And 1000 Mating Cycles, Rj 45 Plug Should Be Of Polycarbonate Fcc Part 68 Subpart F, Ul 94V-0Make: Comscope / Panduit-Pannet / Dlink / Belden 137 Supplying And Laying Of 150 X 50 Mm Gi Cable Raceways With Top Press Cover And 10 Mm Threading Rods Clamps Without Powder Coat. 138 Supplying, Installation, Cabling, And Labeling Of 19”, 42 U800 X 800Network Rack –With Cutouts For Cable Entry. Color: Black / Gray1 ) Front Perforated Single Door- 1No"S 2 ) 230V Ac Fan Assy Fully Wired - 1 Set 3 ) 1U Pvc Horizontal Cable Manager – 12 No"S 4 ) Pvc Vertical Cable Organisers – 2 No"S5 ) Vertical Pdu, 5 / 15A, Socket Strip With Min 12 Sockets With Indicators With 3 Mtr Power Chord With 16A Plug –1 No"S6 ) With Required Fitting Accessories Including Lock And Key. Make :Apw President / Rittal / Netrack 139 Supplying, Installation, Configuration And Testingof Data Switch With 24-Port 100 / 1000 Mbps Rj45 Ports Switch With Min Of 2 X1gb / 10 Gb Sfp / Sfp+ Interface Ports, Switching Capacity128 Gbps ( Stacking Bw Of 40Gbps ) Or Higher, Ram 512Mb Or Higher , Stacking Bw 40 Gbps Or Higher Including Stacking Cable And Etc, Including Power Supply, Fan, Ipv6 Certified Logo, Oem Warranty Of 1 Year And Service Contracts For 1 Year And Oem Authorizationmake :Cisco / Hp / Extreme / Juniper / Dlink 140 Supplying, Installation, Configuration And Testingof Data Switch With Poe24-Port 100 / 1000 Mbps Rj45 Ports Switch With Min Of 2 X1gb / 10 Gb Sfp / Sfp+ Interface Ports, Switching Capacity128 Gbps ( Stacking Bw Of 40Gbps ) Or Higher, Ram 512Mb Or Higher , Power Supply Of 370W , Stacking Bw 40 Gbps Or Higher Including Stacking Cable Etc, Including Power Supply, Fan, Ipv6 Certified Logo, Oem Warranty Of 1 Year And Service Contracts For 1 Year And Oem Authorizationmake :Cisco / Hp / Extreme / Juniper / Dlink 141 Supplying, Installation, Configuration And Testingof 1000 Base Sfp Opticaltransceiver Module For Single Mode Fiber , 1310-Nm Wavelength, Compatible With The Ieee 802.3Z , Dual Lc Connector With Speed On 1Gbps, Sfp Optical Transceivers Should Support Above Switch Modules Of Bom, Switch And Sfp Modules Should Be Of Same Makes.Oem Warranty Of 1 Year Make :Cisco / Hp / Extreme / Juniper / Dlink. 142 Air Conditioning Works 143 Supply, Installation, Testing And Commissioning Of Factory Built Floor Mounted Cabinet Type Horizontal / Vertical Double Skin Type Air Handling Unit ( Ahu ) For Of Capacitynot Less Than 22 Tr, Total Dehumidified Cfm 8800, 35Mm Esp Complete With Didw Backward Curved Centrifugal Fan With Vfd Compatible Motor, Motor Class- Ie2, Mixing Box With Provision For Connecting Return Air And Fresh Air With Damper, Provision For Electric Strip Heater, Internal Power / Control Cabling, Belt Drive System, Spring Type Isolation System ( Min. Vibration Isolation Efficiency 90% ) , Pre Filters With 90% Efficiency Down To 10 Μm ( Eu -4 ) , Fine Filters With 95% Efficiency Down To 5 Μm, Dx Cooling Coil 6 Rows Deep Of Copper Tubes With Aluminium Fins Suitable For Working With Dx Condensing Outdoor Unit, Min.1.2 Mm Thick Ss-304 Drain Pan With 13 Mm Nitrile Rubber Insulation, Fire Proof Flexible Connection At Outlet. Ahu Outerskin Shall Be 0.8Mm Pre-Coated Gss, Inner Skin Shall Be 0.8 Mm Plain Gi With Thermal Break Profile. Panels Shall Be 43± 2 Thick With Puf Injected With Density Not Less Than 38Kg / M3. The Quoted Price Shall Include The Price Of Necessary Control Wiring And Necessary Control Wiring And Necessary Kit For Interlocking Fan Shall Be Considered. Note:1 ) The Capacity Indicated Above Is For Reference Only, The Contractor Shall Design And Indicate The Actual Size, If Higher Size Units Are Required.2 ) The Pcc Pedestal / Bed Provided For Installation Of Ahu Will Be Measured And Paid Under The Relevant Item Of Soqr. 3 ) The Rate To Be Quoted For The Ahu Shall Be Excluding The Cost Of Ms Frame / Brackets / Supports. Thems Frame / Brackets / Supports Will Be Measured And Paid Separately Under The Relevant Item Of Soqr. 144 Supply, Erection, Testing And Commissioning Of Air Cooled Condensing ( Outdoor ) Unit Of Capacity Not Less Than 22 Tr ( 11Trx 2Nos Modules ) Suitable For Dx Air Handling Unit Mentioned In Item No. 1 Of Soqrcomplete With Scroll Compressor, R407c / R410a Refrigerant Gas, Thermostatic Expansion Valves, Condenser Coil With Suitable Size Fan & Motor, All Necessary Controls / Protection Viz., Thermostat, Hp / Lp Cut Out, Microprocessor Based Control Unit Including Necessary Power And Contol Wiring Between Air Handling Unit And Condensing Units, All As Specified And / Or Directed Etc., Complete. Note: 1 ) The Pcc Pedestal / Bed / Ms Frame / Brackets / Supports Provided For Installation Of Condensing Unit Will Be Measured And Paid Under The Relevant Item Of Soqr. 145 Supply, Erection, Testing And Commissioning Of Suitable Size Refrigerant Grade Copper Piping Between Dx Ahu ( Soqr No. 1 ) And 22 Tr Outdoor Condensing Unit ( Soqr No. 2 ) For Suction, Liquid And Discharge Lines Including All Fittings, Accessories, Tube Type Nitrile Rubber Insulation With Frp / Glass Cloth Rapped Over Insulation From Indoor To Outdoor Unit With Uv Resistant Paint Orclosed Cell Physically Crosslinked Polyolefin Foam With Frp / Glass Cloth Rapped Over Insulation With Uv Resistant Paint ( For Both Suction And Liquid Line ) , Anti Corrosive Paint Suitable For Exposed Joints, Sleeve ( Wall Crossing ) , Supports, Core Cutting In Brick / Concrete Wall As Required And Making Surface Good, Etc., All As Specified And / Or Directed Etc., Complete. Note: Both Suction And Liquid Piping Will Be Treated As One Unit And Will Not Be Measured Separately. Also Irrespective Of Number Of Pipes / Circuits The Measurement Of Pipes Will Be Made Only Once Between 22 Tr Capacity Condensing Unit ( Soqr No. 2 ) And Ahu ( Soqr No. 1 ) . 146 Supply, Erection, Testing And Commissioning Of Cassette Ac ( Four Way ) Of Cooling Capacity Not Less Than 3Tr, Inverter Type Rotary / Scroll Compressor, Aircooled Condensing Unit With Copper Cooling Coil, Fan Motor And Indoor Unit Complete With Filter Section, Cooling Coil Of Copper Tubes With Aluminium Fins, Electric Motor, Fans Includinginitial Charge Of R410a / R32 Refrigerant And Subsequent Charge / Tapping Of Refrigerant During Testing / Commissioning If Any, Etc. As Required, Including Minor Civil Works Like Core Cutting, Msstand / Supports For Ac Units All As Specified And / Or Directed Etc., Complete.Quoted Price Shall Include Cost Of Wireless Remote Controller, Cooling Thermostat, Required Length Of Power Cable With Plug Top And Control Cable Between Indoor And Outdoor Units, Earthing. Unit Shall Be Provided With Auto Clean Mode, Auto Timer Setting And As Per Specifications. 147 Supply, Erection, Testing And Commissioning Of High Wall Mount Type Split Ac Units Of 1.5 Tr Capacity, Minimum 5 Star Rating Inverter Type Rotary / Scroll Compressor, Aircooled Condensing Unit With Copper Cooling Coil, Fan Motor And Indoor Unit Complete With Filter Section, Cooling Coil Of Copper Tubes With Aluminium Fins, With Anti Corrosive Paint Suitable For Coastal Application, Electric Motor, Fans Includinginitial Charge Of R410a / R32 Refrigerant And Subsequent Charge / Tapping Of Refrigerant During Testing / Commissioning If Any, Etc. As Required, Including Minor Civil Works Like Core Cutting All As Specified And / Or Directed Etc., Complete. Quoted Price Shall Include Cost Of Wireless Remote Controller, Cooling Thermostat, Wiring, Control Cabling And Earthing. Unit Shall Be Provided With Auto Clean Mode, Auto Timer Setting And As Per Specifications. 148 Providing Ms Frame For Split Ac Outdoor Condensing Unit Including Painting With Two Coats Of Synthetic Enamel Paint Of Approved Make And Shade, Over A Coat Of Approved Steel Primer Etc., Complete 149 Supply, Erection, Testing And Commissioning Of Refrigerant Grade Copper Piping Between Indoorand Outdoor Units Of Suitable Size ( Both Suction And Discharge Piping Will Be Treated As One Unit And Will Not Be Measured Separately ) , Suction Line And Discharge Line Both With Insulation, Frp / Glass Cloth Rapped Over Insulation From Indoor To Outdoor Unit With Uv Resistant Paint; Anti Corrosive Paint For Exposed Copper Piping, Joints, Fittings, Accessories; Core Cutting In Brick / Concrete Wall As Required And Making Surface Good, Supports Etc. For 3Trcapacitycassette Ac Units 150 Supply, Erection, Testing And Commissioning Of Refrigerant Grade Copper Piping Between Indoorand Outdoor Units Of Suitable Size ( Both Suction And Discharge Piping Will Be Treated As One Unit And Will Not Be Measured Separately ) , Suction Line With Insulation And Discharge Line Without Insulation, Epoxy / Frp Uv Resistant Paint Suitable For Exposed Insulation And Anti Corrosive Paint Suitable For Exposed Copper Piping And Joints, Fittings, Accessories, Core Cutting In Brick / Concrete Wall As Required And Making Surface Good, Supports Etc. For 1.5Trcapacity High Wall Split Ac Units 151 Providing Voltage Stabiliser Of Suitable Rating For Input Range Of 180 V To 260 V With Time Delay, High / Low Cut Off, Meter To Read Input And Output Voltages, On / Off Switches Etc. As Required Suitable For 1.5Tr High Wall Split Ac Units 152 Providing Voltage Stabiliser Of Suitable Rating For Input Range Of 180 V To 260 V With Time Delay, High / Low Cut Off, Meter To Read Input And Output Voltages, On / Off Switches Etc. As Required Suitable For 3Tr Cassette Ac Units 153 Providing And Laying Of Cpvc ( Sdr11 ) Pipes Of 25 Mm Dia, With 9 Mm Thick Elastomeric Nitrile Rubber Tubular Insulation Laminated With Glass Cloth And Uv Paniting Of Thickness As Specified In Tender For Condensate Water Drain From The Split Ac Indoor Units To Nearest Drain Point, Fittings, Supportincluding Core Cutting In Brick / Concrete Wall As Required And Making Surface Good Etc. Complete 154 Providing And Laying Of Cpvc ( Sdr11 ) Pipes Of 32 Mm Dia, With 9 Mm Thick Elastomeric Nitrile Rubber Tubular Insulation With Frp / Glass Cloth Rapped Over Insulation For Condensate Water Drain From The Ac Indoor Units To Nearest Drain Point, Fittings, Supportincluding Core Cutting In Brick / Concrete Wall As Required And Making Surface Good Etc. Complete 155 Providing And Laying Of Cpvc ( Sdr11 ) Pipes Of 40 Mm Dia, With 9 Mm Thick Elastomeric Nitrile Rubber Tubular Insulation With Frp / Glass Cloth Rapped Over Insulation For Condensate Water Drain From The Ac Indoor Units & Ahus To Nearest Drain Point, Fittings, Supportincluding Core Cutting In Brick / Concrete Wall As Required And Making Surface Good Etc. Complete 156 Providing And Laying Of 75Mm Size Pvc Casing Suitable For Refrigerant Piping And Control Cable Between Split Ac Indoor And Outdoor Unit With Necessary Fittings, Supports Etc., All As Specified And / Or Directed Complete 157 Supply, Installation, Testing And Commissiong Of Inline Type Propeller Fresh Air Fan Ofcapacity Not Less Than 150 Cfm, Pressure Not Less Than 15 Mm Esp With Canvass / Flexible Duct As Required For Connecting The Inline Fan To The Fresh Air Intake Duct Including Providing Plenum If Required For Connecting The Fresh Air Fan To The Duct And Providing Filter, Louvre, Bird Screen At The Air Intake Point With Necessary Clamps, Screws Etc., All As Specified And / Or Directed Etc., Complete 158 Supply, Fabrication, Installation, Testing And Commissioning Of Site Fabricated Gi Sheet Metal Ducts Of 24 Guage ( Birmingham Gauge ) ( 0.63 Mm ) And Zinc Coating Not Less Than 120 G / M2 In Accordance With Approved Drawings Complete Withsupports, Rubber Gaskets, Rivets, Flanges, Etc., All As Specified And / Or Directed Etc., Complete. Note:1 ) The Rate Quoted For The Gi Ducting Deemed To Include The Cost Of Ms Supports. The Ms Supports Provided For Gi Ducting Will Not Be Measured And Paid Separately. 159 Supply, Fabrication, Installation, Testing And Commissioning Of Site Fabricated Gi Sheet Metal Ducts Of 22 Guage ( Birmingham Gauge ) ( 0.8 Mm ) And Zinc Coating Not Less Than 120 G / M2 In Accordance With Approved Drawings Complete Withsupports, Rubber Gaskets, Rivets, Flanges, Etc., All As Specified And / Or Directed Etc., Complete. Note:1 ) The Rate Quoted For The Gi Ducting Deemed To Include The Cost Of Ms Supports. The Ms Supports Provided For Gi Ducting Will Not Be Measured And Paid Separately. 160 Supply, Fabrication, Installation, Testing And Commissioning Of Site Fabricated Gi Sheet Metal Ducts Of 20 Guage ( Birmingham Gauge ) ( 1.0 Mm ) And Zinc Coating Not Less Than 120 G / M2 In Accordance With Approved Drawings Complete Withsupports, Rubber Gaskets, Rivets, Flanges, Etc., All As Specified And / Or Directed Etc., Completenote:1 ) The Rate Quoted For The Gi Ducting Deemed To Include The Cost Of Ms Supports. The Ms Supports Provided For Gi Ducting Will Not Be Measured And Paid Separately. 161 Supply, Fabrication, Installation, Testing And Commissioning Of Factory Fabricated Gi Sheet Metal Ducts Of 24 Guage ( Birmingham Gauge ) ( 0.63 Mm ) And Zinc Coating Not Less Than 120 G / M2 In Accordance With Approved Drawings Including Necessary Hangers, Supports, Rubber Gaskets, Rivets, Flanges Etc., All As Specified And / Or Directed Etc., Complete Note: 1 ) The Rate Quoted For The Gi Ducting Deemed To Include The Cost Of Ms Supports. The Ms Supports Provided For Gi Ducting Will Not Be Measured And Paid Separately. 162 Supply, Fabrication, Installation, Testing And Commissioning Of Factory Fabricated Gi Sheet Metal Ducts Of 22 Guage ( Birmingham Gauge ) ( 0.8 Mm ) And Zinc Coating Not Less Than 120 G / M2 In Accordance With Approved Drawings Including Necessary Hangers, Supports, Rubber Gaskets, Rivets, Flanges Etc., All As Specified And / Or Directed Etc., Complete Note: 1 ) The Rate Quoted For The Gi Ducting Deemed To Include The Cost Of Ms Supports. The Ms Supports Provided For Gi Ducting Will Not Be Measured And Paid Separately. 163 Supply, Fabrication, Installation, Testing And Commissioning Of Factory Fabricated Gi Sheet Metal Ducts Of 20 Guage ( Birmingham Gauge ) ( 1.0 Mm ) And Zinc Coating Not Less Than 120 G / M2 In Accordance With Approved Drawings Including Necessary Hangers, Supports, Rubber Gaskets, Rivets, Flanges Etc., All As Specified And / Or Directed Etc., Complete Note: 1 ) The Rate Quoted For The Gi Ducting Deemed To Include The Cost Of Ms Supports. The Ms Supports Provided For Gi Ducting Will Not Be Measured And Paid Separately. 164 Supplying And Fixing Thermal Insulation For Supply Air Ducts With 19 Mm Thick Self Adhesive Closed Cell Elastomeric ( Nitrile Rubber ) Sheet Reinforced With Aluminium Foilor Closed Cell Physically Crosslinked Polyolefin Foam Reinforced With Aluminium Foil All As Specified And / Or Directed Etc., Complete 165 Supplying And Fixingthermal Insulation For Return Air Ducts With 13 Mm Thick Self Adhesive Closed Cell Elastomeric ( Nitrile Rubber ) Sheet Reinforced With Aluminium Foilor Closed Cell Physically Crosslinked Polyolefin Foam Reinforced With Aluminium Foil All As Specified And / Or Directed Etc., Complete 166 Supplying And Fixing Acoustic Insulation For Ducting With Open Cell Nitrile Rubber Insulation Or Open Cell Physically Crosslinked Polyolefin Foam Insulation Of Thickness Not Less Than 15 Mm, Density Of Open Cell Nitrile Rubber Insulation Shall Not Be Less Than 130 Kg / M3 Including Adhesive Or Density Of Open Cell Physically Crosslinked Polyolefin Foam Shall Not Be Less Than 25 Kg / M3 Including Adhesive, Fixing Accessories All As Specified And / Or Directed Etc., Complete 167 Supplying And Laying Of Under-Deck Insulation With 25Mm Thick Closed Cell Elastomeric Nitrile Rubber / Closed Cell Physically Crosslinked Polyolefin Foam With Adhesive ( Fevicol Sr 505 ) , Gi Strip And All Necessary Support All As Specified And / Or Directed Etc., Complete. Note: Insulation Measurement Shall Be As Per The Tender Measurement Clause. 168 Supply, Erection, Testing, Balancing And Commissioning Of Aluminium Powder Coated Supply Air Grill With Vcd, Double Defelection Adjustable Blades As Per Requirement / Approved Drawingsincluding Fixtures, Screws Etc All As Specified And / Or Directed Etc., Complete 169 Supply, Erection, Testing, Balancingand Commissioning Of Aluminium Powder Coated Return Airgrill ( Without Volume Control Dampers ) As Per Requirement / Approved Drawings Including Fixtures, Gasket, Screws Etc., All As Specified And / Or Directed Etc., Complete. 170 Supply, Fixing, Testing & Commissioning Of Supply Air Diffusers With Powder Coated Aluminium Single Piece Moulded Frame With Opposed Blade Aluminium Extruded Construction Black Anodised Dampers As Per Requirement / Approved Drawing Including Fixtures, Gaskets, Screws, Etc., All As Specified And / Or Directed Etc., Complete. 171 Supply, Fixing, Testing & Commissioning Of Return Air Diffusers With Powder Coated Aluminium Single Piece Moulded Frame Without Dampers As Per Requirement / Approved Drawing Including Fixtures, Gaskets, Screws, Etc., All As Specified And / Or Directed Etc., Complete. 172 Supply & Installation Of Factory Fabricated Spill Air Boxes Made Out Of 0.8Mm Thick Gi Sheet With Necessary Spigot Connection For Fixing Flexible Duct And Suitable Collar For Connecting To Various Neck Diffuser / Slot Diffuser.The Box Should Be Internally Insulated With 6Mm Thick Nitrile Rubber Of Class "O" Material. Box Size Shall Be Of 450X450x350 Mm And Equivalent Required Rectangular Sizes With Gi Wire Support, 16G Gi U-Shaped Brackets With Gi Nut Of Suitable Size Welded To It. 173 Supply, Erection Testing And Commissioning Of Volume Control Dampers Forducts Made Of Gi Sheet Of Thickness Not Less Than 18 G Including Fittings, Gaskets, Nuts.Boltsetc., All As Specified And / Or Directed Etc., Complete 174 Supply, Installation, Testing And Commissioning Ofcombined Fire And Smoke Damper To Be Fitted At The Supply Air Wall Openings ( Inside Wall ) . These Dampers Shall Be Made From Gi Sheet In Multi Blade Construction. The Dampers Shall Be Provided With Seal On Sides To Prevent Spread Of Smoke And Fire. Testing Of Fire Damper Shall Be As Per Ul 555 And Certified By Cbri. All As Specified And / Or Directed Etc., Complete. 175 Supply, Installation, Testing And Commissioning Of Control Instruments And Sensorsrequired For Combined Fire And Smoke Damper Including Actuators, Temperature Sensor And Duct Mounted Smoke Sensor And Auxiliary Switch With All The Necessary Accessories For Fire & Smoke Damper ( Item No. 32 Of Soqr ) All As Specified And / Or Directed Etc., Complete.Note: 1 ) The Item Shall Be Complete With In-Built Temperature Sensor And Duct Mounted Smoke Sensor And Auxiliary Switch To Close The Dampers Simultaneously. 2 ) The Components Provided Under This Item Shall Be Such That The Dampers Also Actuate In Response To Signal From Central Fire Alarm System Which Shall Trip The Indoor Unit Along With Closing The Damper.3 ) The Cabling From The Central Fire Alarm System Upto The Combined Fire And Smoke Damper Will Be Provided By The Fire Alarm System Contractor.4 ) The Damper Will Be Measured And Paid Under The Relevant Item Of Soqr. 176 Supply, Erection Testing And Commissioning Of Fresh / Exhaust Airlouvers Made Of Extruded Aluminium With Bird / Insect Screen Including Volume Control Damper Made Of Aluminium. Note : The Lowest Louvers Of The Assembly Shall Extend Out Slightly To Facilitate Disposal Of Rain Water Without Falling On The Door / Wall On Which It Is Mounted All As Specified And / Or Directed Etc., Complete. 177 Supply, Erection, Testing And Commissioning Of 300Mm Dia. - Butterfly Damper Should Constructed With Not Less Than 0.8Mm Thick Galvanized Steel Sheet, With Single Flap, Necessary Stopper, Flanges For Fastening On To The Duct Surface And With Grooves For Clamping The Flexible Ducts Securely All As Specified And / Or Directed Etc., Complete 178 Supply, Erection, Testing And Commissioning Of 250Mm Dia. - Butterfly Damper Should Constructed With Not Less Than 0.8Mm Thick Galvanized Steel Sheet, With Single Flap, Necessary Stopper, Flanges For Fastening On To The Duct Surface And With Grooves For Clamping The Flexible Ducts Securely All As Specified And / Or Directed Etc., Complete 179 Supply, Erection, Testing And Commissioning Of 100 Mm Dia. - Butterfly Damper Should Be Constructed With Not Less Than 0.8 Mm Thick Galvanized Steel Sheet, With Single Flap, Necessary Stopper, Flanges For Fastening On To The Duct Surface And With Grooves For Clamping The Flexible Ducts Securely.All As Specified And / Or Directed Etc., Complete 180 Supply, Erection Testing And Commissioning Of Aluminium Flexible Duct Of 300 Dia With Insulation All As Specified And / Or Directed Etc., Complete 181 Supply, Erection Testing And Commissioning Of Aluminium Flexible Duct Of 250 Dia With Insulation All As Specified And / Or Directed Etc., Complete 182 Supply, Erection Testing And Commissioning Of Aluminium Flexible Duct Of 100 Mm Dia With Insulation All As Specified And / Or Directed Etc., Complete. 183 Supply And Fixing Of Hand Held Carbon Dioxide Type Fire Extinguisher Of 4.5 Kg Capacity As Per Is - 2878, Duly Charged, With Bis / Isi Mark, Complete With Accessories Including Placing At A Suitable Location With Floor Mounting Type Ms Stand Or Mounting With Suitable Fixture On Wall / Column Etc., All As Specified And / Or Directed Complete. The Contractor Has To Furnish A Copy Of Bis / Isi Certificate And Controller Of Explosive Certificate Along With The Extinguishers, Complete In All Respect. 184 Supply And Fixing Of Hand Held Fire Extinguisher - Abc Powder - 6 Kg Capacityas Per Is - 13849 / 14609, Duly Charged, With Bis / Isi Mark, Complete With Accessories Including Placing At A Suitable Location With Floor Mounting Type Ms Stand Or Mounting With Suitable Fixture On Wall / Column Etc., All As Specified And / Or Directed Complete. The Contractor Has To Furnish A Copy Of Bis / Isi Certificate Along With The Extinguishers, Complete In All Respect.
|