Purchase Of Laboratory Equipments For Veterinary College Gadag Tender Title - 1. Kg-1-7301 Laboratory Spectrophotometer For Water Analysis With All Accessories • Technical Specifications • Beam Height:10 Mm, Data Logger:2000 Measured Values ( Result, Date, Time, Sample Id, User Id ) , Display:7” Tft, Display Resolution: Wvga ( 800 Pix X 480 Pix ) , Display Size:7 Inch ( 17.8 Cm ) , Display Type: Color Touch-Screen. • System Configuration Accessories, Spares And Consumables • System To Be Supported By A Laptop With Laserjet Colour Printer With Suitable Configuration For Storage And Printing Of Data. • All The Accessories Required For Running The Equipment With Our Desired Samples Including Reagents / Kits, Should Be Supplied With Free Of Cost. • Manpower And Training • The Supplier Must Provide Training For The Users Of The Instruments At Site After Installation And Commissioning. Details Of The Training Program Must Be Attached With The Tender • Training Should Be Provided For At Least 4 Users For The Operation, Trouble Shooting And General Maintenance Of The System. • There Should At Least Be Another Training Session From The Supplier’S Application Specialist Which Can Be Customized To The Users’ Needs Within A Year Of Installation Of The Instrument. • Environmental Factors • The Unit Shall Be Capable Of Operating Continuously In Ambient Temperature Of 10 -40 °C And Relative Humidity Of 15-90%. • Power Supply • Power Input To Be 220V, 50Hz Fitted With Indian Plug.Voltage Corrector / Stabilizer Of Appropriate Ratings Meeting Isi / Bis Specifications Suitable To The Equipment. Suitable Ups Shall Be Provided Preferably 1 Kva From M / S.Apc ( Www.Apc.Com ) • Standards And Safety • Should Be Compliant To Iso Quality Systems - Particular Requirements For The Application Of Iso 9001 Applicable To Manufacturers And Service Providers That Perform Their Own Design Activities. • Electrical Safety Conforms To Standards For Electrical Safety Iec-60601 / Is-13450 • Documentation • User / Technical / Maintenance Manuals To Be Supplied In English. • Log Book With Instructions For Daily, Weekly, Monthly And Quarterly Maintenance Checklist. The Job Description Of The Technician And Company Service Engineer Should Be Clearly Spelt Out. • List Of Important Spare Parts And Accessories With Their Part Number And Costing. • Certificate Of Calibration And Inspection • List Of Equipments Available For Providing Calibration And Routine Maintenance Support As Per Manufacturer Documentation In Service / Technical Manual. • Warranty • Warranty At Site For 12 Months, 5 Years Comprehensive Amc Should Be Available With Service Centers In Close Proximity. It Has To Be Clearly Enclosed With The Tender Document. 2. Kg-1-7302 Micro Plate Elisa Reader: • A Monochromator Based Elisa Reader With Xenon Flash Lamp As Light Source For Better Performance. • The System Should Able To Read 96 & 384 Well Plates • Should Have An Option For Pathlength Corrections. • Instrument Should Able To Provide The Wavelength Range From 200Nm To 1000Nm With 1 Nm Steps. • Should Have Spectral Scanning Option For Standardizing New Assays. • The Instrument Applications Should Include Nucleic Acid Quantification, Protein Assays, Enzyme Kinetic Assays, Immunoassays, Cell Toxicity Assays, Apoptosis And Reporter Gene Assays. • The Instrument Should Have Inbuilt Incubation And Linear Shaking Options. • Incubation Temperature: From Ambient +4 0C To +45 0C. • Measurement Speed Should Be 6 Sec. For 96 Well And 10 Sec. For 384 Well Plate • The Instrument Should Be An Open System, Able To Accommodate Any Consumables From Any Manufacturer. • The Instrument Should Run In Stand-Alone Mode Or With Computer & Software Controlled. • The Instrument Should Have A Memory For 100 Inbuilt Protocols In Stand-Alone Mode. • The Instrument Should Have Usb Port For The Easy Data Transfer. • A Suitable Software Programme For Analysis Should Be Supplied • Suitable Computer, Printer, Ups And Required Multi Channel And Single Channel Pipettes Should Be Supplied. 3. Kg-1-7303 Kjeldhal Protein Distillation Unit Specification: Transparent Door Glass Protected From Spillage, Should Have Iso 17025 Certification Fully Automatic Distillation Unit Chemical Resistant With Plastic Housing Lcd Display, Tft Touch Screen ( Minimum Size 7” ) With Embedded Pc And Micro Controller Protection From Low Voltage And Fluctuation Programming Functions For Automatic Addition Of Naoh Features Of Calibration Of Pumps, Safety Features For Tube, Door Sensors, Excess Temperature And Pressure. Detection Limit And Distillation Time ( 0.1 Mg ) , 2 To 4 Minutes Per Sample 4. Kg-1-7304 Kjeldhal Digestion Unit ( Protein Estimation ) Specifications: Number Of Tubes And The Capacity -12 X 300 Ml, Digestion Unit Based On Infrared Digestion Technology With Short Heating And Cooling Time ( Approximately Need 10 Minutes To Boil 12 Samples ) , Console Attachment Should Have Insert Rack, Exhaust Equipment And Drip Tray Microprocessor Controlled Up To 99 Programmes Storage, Should Contain Pre-Defined Methods, Infinitely Variable Heating Power And Time Periods Ergonomically Designed Operating Unit With Variable Inclination Continuous Display Of Running Digestion Status, Correction Of Running Programme At Any Time. Iso 17025 Conform Data Management Regarding: - Traceability, - Different User Levels With Defined Rights And, Password Protection., Recording And Recalling Of All Relevant Process Data. Digestion System Should Supply With Scrubber. Nominal Wattage 1600 Dimensions: W / D / H ( Mm ) : 636 / 354 / 740. Frequency ( Hz ) : 50 / 60 Weight: Ca 29, Maximum Temperature 6500 C 5. Kg-1-7305 Trinocular Microscope: ( Bright Field, Dark Field And Phase Contrast ) With Computer Observation Method: Bright Field, Dark Field And Phase Contrast Illumination: Transmitted Kohler Illumination, Led Lamp, Focusing Mechanism: Stage Focus Intermediate Magnification Changer: Manual Torret Revolving Nose Piece: Manual, Coded 7 Positions Stage: Manual With Right Hand Control X:76Mm Y:52Mm Palin Stage :Dimension 180Mm * 150Mm Rotatable Graduated Stage ( 3600 ) Condenser: Manual Universal ( Na 0.9 / W.D. 1.5 Mm For 1.25X–100X [ Swing-Out: 1.25X–4X, With Oil Top Lens: ( Na 1.4 / W.D. 0.63 Mm ) ] Swing Out Condenser: Na 0.9 / W.D. 2 Mm ( 1.25X–100X ) Achromatic / Aplanatic Condenser: Na 1.4 / W.D. 0.7 Mm ( Oil ) ( 10X–100X ) Darkfield Condenser Dry: Na 0.8–0.92 / W.D. 4.52 Mm ( 10X–40X ) Darkfield Condenser Oil: Na 1.2–1.4 / W.D. 0.5 Mm ( 20X–100X ) Low Magnification Condenser:Na 0.75 / W.D. 1.55 Mm ( 2X–100X ) Abbe Conenser:Na 1.1 / W.D. 0.7 Mm ( Oil ) ( 4X–100X ) Phase Contrast Condenser: Na 1.1 / W.D. 0.7 Mm ( 4X–100X ) Observation Tubes: Binocular, Tilting Binocular, Tilting Trinocular, Ergonomic Tilting Binocular, Tilting, Telescopic, Lifting Binocular Rinocular For Infrared, Erected Trinocular, Erected Ergonomic Tilting Binocular, Super Widefield ( Fn 26.5 ) Trinocular, Erect Image Tilting Trinocular Camera: Balance Of Resolution And Speed 6.4Mp Color Digital Camara. Sensor Type 1 / 1.8-Inch Color Cmos, Pixel Size 2.4 Μm × 2.4Μm, Dynamic Range 10 Bit, Manual Exposure: 13 Μs–15 S, Auto Exposure: 13 Μs–15 S, Usb 3.1 Type-C. Live Image Display ( Frame Rate ) 45 Fps ( Full Resolution ) , 59 Fps ( Binning 2 × 2—High Speed ) , 60 Fps ( Full Hd ) . High Resolution At 30 Frames Per Second ( Fps ) , High Color Reproduction, Maximize The Advantage Of A Wide Field Of View Up To Fn25, Suppresses Noise While Maintaining Fast Frame Rates And Eliminating Artifacts. High Contrast Mode Enabling Easier Image Acquisition With A High Signal -To- Noise Ratio, Fast Live Function With Ability To Capture Full Hd Images At 60 Fps. Focus Peaking Function* Scale Bar Display, Info Stamp, Zoom Magnification. Suitable Image Analysis Software With Computer And Accessories To Capture High Quality Images, Processing And Storage With Appropriate Battery Backup. 6. Kg-1-7306 Multiple Eye Piece Demonstrator Or Multihead Microscope: Multiple Eye Piece Demonstrator Or Multihead Microscope: Total Magnification: Penta Head 4+1, 40X – 1000X. Viewing Head: Compensation Free Trinocular Head Inclined At 30° , 360° Rotatable , Interpupillary Distance 48-75Mm. Eye Piece: Extra Wide Field Eyepiece Ew 10X / 22X With Eye Guard. Nose Piece: Inward Quintuple Nosepiece. Objectives: Infinite Plan Achromatic Objective 4X, 10X, 40X, 100X. Focus: Co-Axial Coarse And Fine Focusing System, Fine Division-0.002Mm. Stage: Double Layer Mechanical Stage 185Mmx142mm / 75Mmx55mm. Pointer: Fluoroscent Led Pointer. Condenser: Swing Condenser / Dual Condenser N.A. 0.9 / 0.25 Center Adjustable. Illumination: Exterenal Illumination 24V-100W Halogen Lamp With Brightness Adjustable. 7. Kg-2-7307 C-Arm System: Should Be Aerb Approved-Should Have Lowest Radiation Emissions. Control Panel: High Frequency: Minimum 40 Khz Generator, Output Power: 3.5Kw, Max Kv: 110 Kv And 30 Mas. Microprocessor Based System For Accurate Time Selection For Exposure. Automatic Overload Protection With Visual And Audible Indication For Longer Life Of Tube. Rotating Anode X- Ray Tube Of Focal Spot 0.6 Mm X 1.5 Mm, And Tube Head Temperature Sensor For Thermal Safety Cut Off. Apr Programmes For Radiography. Radiographic Mode And Abs Mode- Continuous And Pulsed Fluoroscopy Upto 12.5 Fps Stand: Motorized Up / Down-400 Mm, Horizontal Movement 200 Mm, Arc Orbital- 90 + 25 Degree Rotation – 180 Degree, Free Space – 800 Mm, Locks For All Movement. C- Arm Swivel On Each Side With Manual Brake For Locking. Fluoroscopy – Pulse Mode, Live Mode, Low Dose, Boost, Single Shot. Boosted Fluoroscopy ( Cine ) Up To 12.5 Fps With Real Time Recording On Hard Disk Drive. 8:1 Anti-Scatter Grid ( Sid-98 Cm, Dia-9 Inch ) Image Intensifier- At Least 9”, Ccd Camera With A Progressive Scan Sensor Of 0.5 Inch With Auto Iris And Nd Filter Integrated Optical System. Software: Storage Of Last Image And Permanent Storage Of 1000 Images ( Optional Pc Memory And Digital Processing Software ) . High Resolution Image Capture, Digital Zoom, Usb Memory Stick Support For Image Back Up, Large Data Image Storage: In Frame By Frame And Movie Mode. Dvd Writer For Recording On The Cd / Dvd, Usb Device To Take Data On Pen Drive. Real Time Image Rotation, Image Flipping ( Horizontal And Vertical ) And Mirror Imaging. Recursive Filters For Image Smoothening, Contrast Enhancement, Negative Image ( Image Inversion ) . Gamma Curve Adjustments For Optimum Quality. Image Zoom With Pan Both In Vertical And Horizontal Direction Measurements: Length And Angle Measurements With Annotation. Pre-Programming For Image Setting For Different Operating Modes. Display Of Live Image With “Last Image Hold” Feature. Image Post Processing For Live / Stored Images. User Selectable Brightness, Contrast For Images. User Friendly, Intuitive Key Pad With Display And Advanced Features For Wider Clinical Applications. Also Has Control And Display For Self Diagnostic Maintenance And Software For Online Support. 8. Kg-1-7308 Paraffin Oven • Temperature: Set Temperature Range In °C Min. 5°C Above Ambient Up To +80°C , Setting Accuracy Temperature: 0.1 °C, Temperature: 2 Pt100 Sensors Din Class A In 4-Wire-Circuit For Mutual Monitoring, Taking Over Functions In Case Of An Error, Control Technology, Control Cockpit Twin Display. Adaptive Multifunctional Digital Pid-Microprocessor Controller With 2 High-Definition Tft-Colour Displays. • Timer Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute To 99 Days, Function Set Point Wait: The Process Time Should Not Start Until The Set Temperature Is Reached, Calibration: Three Freely Selectable Temperature Values • Adjustable Parameters Temperature ( Celsius Or Fahrenheit ) , Programme Time, Time Zones, Summertime / Wintertime, Ventilation Convection: Natural Convection • Communication Documentation Programme Stored In Case Of Power Failure • Safety : Temperature Control Mechanical: Temperature Limiter Switch Off The Heating Approx. 20°C Above Nominal Temperature Temperature Control Over Temperature Monitor. Auto Safety Additionally Integrated Over- And Under Temperature Monitor Alarm Visual And Acoustic, Door Fully Insulated Stainless Steel Door With 2-Point Locking ( Compression Door Lock ) Internals 2 Stainless Steel Grid ( S ) , Electropolished Works Calibration Certificate For +80°C , Stainless Steel Interior, Nearly Gas-Tight, Easy-To-Clean Interior, Capacity: 90 Ltrs, No. Of Shelves : Two 9. Kg-1-7309 Strereozoom Microscope Viewing Head: Trinocular Head Inclined At 450, Eye Piece: Extra Wide Field Eye Piece Ew 10X22mm, Zoom Objective 0.8X To 5X, Magnification : 8X To 50X, Zoom Ratio-6.4:1, Working Distance:115Mm, Interpupillary Distance: 57-75Mm, Glass Insert: Diameter 100Mm, Illumination: Led With Brightness Adjustment, Cmos Camera Tft Screen, Digital Camera, Software, 64Gb Memory, Bluetooth, Usb Ports 10. Kg-1-7310 Small Animal Post Mortem Table Made Of 18 G Ss, Supported On Powder Coated Metal Frame Size: 3 ½ ( W ) *10 ( L ) *3 Feet ( H ) With Gradient Of 1’’. Draining Facility, Having Depth Of 6” In The Centre And 3 ‘’ At The Periphery, Attached Ss Sink With Laboratory Long Handle Tap. 11. Kg-1-7311 Obstetrical Sets For Large Animals Thygens Embrotome With Wire & Handle, Calving Rope, Wire Introducer, Keys Schuler Hook, Nose Handle, Extension Piece, Sharp Hook, Blunt Hook, Hook With Probe Pointed, Obey Meyer S Hook 12. Kg-1-7312 Computerized Radiography System Specification 1. The Cr System Should Be Suitable To Use For Small And Large Animals With Veterinary Specific Software And Should Handle At Least 68 Cassettes Per Hour Or More. 2. The Cassette Scanner Should Not Be Of Roller Type And Should Be Contact Less Scanning System For Long Life Of The Cassette And Better Image Quality. System Should Have Auto Inline Eraser. 3. Assists In Diagnosis With Software Tools That Provide Easy Calculation Of Critical Dimensions. • Features Dicom Functionality And Connectivity 4. Functional Installation With Suitable Earthing. Should Be Supplied With Ups With A Power Back Up Of At Least 20 Minutes. Complete Functional Demonstration And Providing Cr Table And Cooling Ac Device Of 1.5 Ton Will Be Company Responsibility 5. Computer: Processor: Core I5 5Th Generation, Ram : 4Gb, Os: Windows 8.1 Licensed Original Must Be Upgradable To Windows 10 ( Official Version ) , Hdd: At Least 2Tb 6. Should Be Supplied With 3 Nos. Cassettes Of 14X17” Each With Telescopic Cassette Holder For Cassette Size 14X17” For Taking X-Ray Of Spines And Areas Which Are Difficult To Shoot. Also Should Be Supplied With Alteast Two Long Cassette Holder Rods And Handles 7. Should Be Supplied Cassette Block Covers With Skid Proof Rubber Feet For Problem Free X Ray Of Hoofs Along With The Set Of Hoof Instruments. 8. Should Be Supplied With A Partition Based Lead Storage Box For Keeping Exposed And Cassette Unexposed Cassettes 9. Company Should Provide Minimum Three Years Warranty With Full Timely Service And Repairs Including Software Upgradation As And When Needed. 10. Catalogs Must Be Enclosed With The Offer, Without Which The Offer Will Be Rejected Straightway 11. Company Should Provide User List Where Similar Equipments Are Installed 12. User Service Report And Recommendation Certificate To Ascertain After Sales Services Provided By The Company. 13. Kg-1-7313 30 Kw High Frequency Mobile ( Portable ) X-Ray Machine X-Ray Generator. Specification High Frequency X-Ray Generator Having Frequency Of Inverter Type For Constant Output 50Khz. Power Output Of Generator Should Be 30 Kw. Radiographic Kv Range Should Be 40 To 125 Kv. Ma Range ( Rad. ) : Up To 400 Ma. Exposure Time ( Rad. ) : 1Msec To 5Sec. Mas Range ( Rad. ) : 1 To 200Mas. Control Panel: Ergonomically Designed Veterinary Application Based Control Panel With Total Soft Touch Switches Having Following Functions.Machine On / Off Switch, Stand By And Exposure Release Switch. Ready And X-Ray On Switch With Indicators, Digital Display Kv And Mas Increase And Decrease Switches, Bucky Selection Switch, Self Diagnostic Program With Indicators For:- Earth Fault Error, Kv Error, Filament Error, Tube Head Thermal Overload, X-Ray On Indicator. Incoming Voltage Indicator, Anatomical Programming Up To 216 Pre-Programmed Functions In Which Automatic Selection Of Technical Factors Is Done According To The Body Part Selection. Capacitor Bank: A 2-Step Hand Switch With Dual Action For Exposure Release With Retractable Cord Is Provided For Taking Images From A Safer Distance Should Be Provided. X-Ray Tube: One No. Dual Focus Rotating Anode X-Ray Tube Thermally Protected Having Focal Spot Of 0.6 Mm & 1.3 Mm Anode Heat Storage Capacity Of Tube Should Be More Than 107 Khu. Mono-Block Tube Head Is Protected For Thermal Overload.One No. Collimator With Auto Shut Off Facility Should Be Provided. Stand: Fully Counter Balanced Mobile ( Cbm ) Stand With Rotation In All Directions. Effective Braking System For Parking, Transport And Emergency Breaking. Counter Balanced Telescopic Tube Carriage. All Cables Concealed In The Arm System. Lead Lined Cassette Storage Box. Large Castor Nylon Wheels For Easy Mobility. Vertical Bucky Stand ( Vbs ) : Standard Features Details, Floor Mounted Tiltable Vertical Bucky Stand With Counter Balanced Movements For Erect / Supine Examinations And Consisting Of Motorized Oscillating Grid. And Can Move Up And Down And Equipped With A Stainless Steel Cassette Tray & Can Accommodate Cassettes Up To 14" X 17". Mechanical Locks For The Movement To Lock At Any Position. Chest Stand Should Be Provided Along With The Stand For Without Grid Examination. Table:- Table Top Is Made Up Of Radiolucent Material. 4Way- Floating Table Top Movements For Ease Of Patient Positioning Along With Electromagnet Lock Facility With Foot Pedal Release Switch. Table Accessories Like Stainless Steel Cassette Tray, Compression Band Should Be Provided. Power Requirement: Unit Operatable On Single Phase 230V, Ac, 50Hz. 15 Amps With Line Regulation Of ±10%. Accessories: Lead Apron : Five Numbers ( 0.5Mm Thickness ) , Lead Lined Glove : 3 Pairs ( 5-Finger Gloves. 15” Length, 0.5Mm Lead Equivalency, Lead Goggles: 4 No., Gonad Shield: 2 No.S, One-Piece Moulded Construction, Durable Vinyl Covered ) . Thyroid Shield : 5 Nos. ( An Internal Seam And No Top Binding– To Reduce Chafing, Easy Hook And Loop Closure, 0.5-Mm Pb Equivalent Protection ) Half Film Blocker :Lead Partition Sheets For Cassettes To Click Multiple Views On The Same Cassette Exposure ( 2 No Suitable For 14 X 17 Sized Cassettes ) . Cassette Storage Box Made Of Lead For Storing Exposed And Unexposed Cassettes Of 14 X 17 Size ( 1 No ) And Manual Processing Type Of Film Storage Box Made Of Lead For Storing Different Type Of Films ( 1 No ) . Abc ( Three Door ) Foldable Movable Lead Partitions With Viewer Windows For Protection Against Exposure ( 6 X 3 X 3 ) And With Sturdy Wheels And Base Support ( 4 No ) Dosimeter: 3 No ( Along With The Control As Per Aerb Norms ) . Thick Coir Bed Additionally Padded With Foam And With For Casting Large Ruminants ( 5 Feet X 8 Feet X 12 Inches ) And A Rubber Mat For Making The Floor Anti Slippery ( 6 Feet X 10 Feet X 1 Inches ) Other Requirements: The Company Should Be Iso And En-Iso. Unit Should Be European Ce Certified With Notified Body No. The Unit Should Be Approved By Aerb. The Company Should Have A Local Service Center In The State. The Company Should Have Proven Track Record In Govt. Sector. Should Cover The Cost Of Comprehensive Warranty Of All The Item Of The Mobile X-Ray Machine Including X-Ray Tube And Collimator For A Period Of 7 Years, After Warranty Period Of 3 Years And The Cost Of Training. Should Provide Suitable Earthing & Functional Installation. 14. Kg-2-7314 Ultrasonography Specification 1. Portable Ultrasound System With Rechargeable Battery For Scanning In Small And Large Animals. 2. The System Should Come With Species Specific ( At Least For Cattle / Buffalo, Sheep, Goat, Dog And Horse ) Extensive Calculation Packages ( At Least For Veterinary Obstetrics And Gynecology ) And Integrated Imaging And Calculation Package For Veterinary Use. 3. System Should Have Real Time 2D, M-Mode, Pulsed Wave Doppler, Color Flow Imaging And Hardware. 4. System Should Have Dual Live Mode Or Equivalent And Dual And / Or Quad Split Display 4. System Should Have Minimum 10" High Resolution Medical Grade Flat Lcd / Led Monitor. 5. System Should Have Speckle Reduction Technology With Noise And Artifact Reduction For Improving Tissue Clarity And Margin Definition. 6. System Should Have A Dynamic Range Of At Least 170Db 7. System Should Have At Least 4 Active Transducer Ports. 8. Multifrequency, Multifocal Transducers To Be Supplied With The Machine: Convex Array 2- 5 Mhz ( ±1 Mhz ) , Micro Convex Array 6- 10 Mhz Linear Rectal Transducer 4-7 Mhz ( ±1 Mhz ) , Cardiac Probe. 9. System Should Have Facility For Pan And Zoom On Live And Frozen Image. 10. Pw Doppler Analysis In Auto & Manual Mode, Variable Sample Volume, Selectable Wall Filter, Angle Correction 11. System Should Have Inbuilt Minimum Four Usb 3.0 Ports And Lan / Ethernet Port 12. In-Built Hard Drive Capacity Of Minimum 1 Tb 13. System Should Be Dicom 3 Compatible With Life Time Dicom Licence And Upgradable For Pacs. 14. System Should Be Ce Or Fda ( Us ) Approved 15. Accessories To Be Supplied: Free Software Upgrade ( S ) During The Period Of Warranty, Probe Protection Covers I Probe Connector Cover For All Probes, External Hard Disk Of At Least 1 Tb Capacity. 16. Warranty Of 2 Years For The Machine Should Be Included In The Package 17. Delivered Installed Without Any Financial Liability On Vet, College, Gadag. 15. Kg-1-7315 Microhaematocrite Centrifuge Microprocessor Controller With Digital Display, Smooth & Soft Start, Inverter Fault Detection With Auto Shutdown, 7 Segment Led Display Of Speed Digital Countdown Timer & Continuous Run, Dynamic Brake For Quick Deceleration, Last Set Parameters Recall Automatic Door Opening, Stainless Steel Centrifuge Chamber, Easy To Clean, Safety Lid Interlock To Prevent Lid Opening During Centrifugation, Imbalance Detection & Centrifugation Stop With Display Of Error, Motor Overload Protection, Gas Hinge To Prevent Door Falling. Maximum Rcf: 15300 G, Maximum Speed: 12, 000 Rpm Timer To Set Up To 99 Minutes, Speed Adjustable In Increments Of 100 Rpm, Having Emergency Lid Lock Release, Standstill Indicator And An Imbalance Switch-Off 24 Capillaries ( 75*1Mm ) -Places \ Positions, With Reader ( Scale ) 16. Kg-1-7316 Air Sampler Description: Air Sampler ( 90Mm Stainless Steel Head Ready ) Airflow Rate: 100L Of Air Per Minute, Impact Speed: < 20M / Sec 17. Kg-1-7317 Sample Bag Mixer Optimal Blending Volume: 50 - 400 Ml Fixed Speed: 8 Strokes / Second Variable Blending Time: 30 - 210 Seconds Or ∞ • 270° Door Opening Q-Tight Closing 18. Kg-1-7318 Somatic Cell Counter Fully Automatic Somatic Cell Counter With Following Features: Analysis Time: 20-60 Sec Measuring Range: 0– 10, 000, 000 Cell / Ml Measuring Cell Size: 2-30 Μm Colour Indication For Sub-Clinical And Clinical Mastitis 19. Kg-1-7319 Hot Plate Bench ( Cf Estimation ) Model P40-H Hot Plate Temperature Range - 80-380°C / 176-716°F, Electrical Data -115V, 5A, 50 / 60Hz 230V, 3A, 50 / 60Hz Power Consumption -500W, Size:455*345 Mm 20. Kg-1-7320 Livestock Mineral Mixture Preparation Unit • Pulveriser / Hammer Mill – Full Circle With Motor Foundation Stand, 3 Sect Screen Pulley, Hopper And Other Accessories. 10” X 21” X 25” • Branded Motor For Hammer Mill – 10 Hp / 7 Kw, 1440 Rpm, Foot Mounted • Horizontal Feed Mixer – 50 Kg Capacitystainless Steel ( Food Grade / Ss304 ) With Stand For Motor And Mixer. • Branded Motor For Mixer – 5 Hp / 3.7 Kw, 1440 Rpm, Foot Mounted • Manual Packaging Machine – For Upto 25 Kg Bags • Electronic Weighing Machine – 100 Kg Capacity 21. Kg-1-7321 Model Of Various Livestock And Poultry Farming Systems- Made With Fibre Glass Unbreakable Material Modern Diary: - Model Of An Up-To-Date Dairy Having Clean And Ventilated Cattle Sheds With Up-To-Date Feeding Arrangement Showing Pasteurization Room, Creamery And Testing Laboratory. This Is A Model Complete In All Respects. Size 20” X 28”. Medieval Dairy: - Model Of An Old Type In Sanitary Dairy Having Katcha Floor, Thatched Roofing, Dung Heaps And Urine Everywhere. Showing Rickety Sheds. Cattle Sitting In Dung And Urine. Some Living Houses Nearby Are Also Depicted In A Most Dirty Unhygienic Condition; Size 20” X 28”, Modern Cattle Shed :- Model Of 10 Stall, Single Face Cattle Shed For Clean Milk Production, Having Standing Platform, Gutter, Brick Floor, Katcha Floor, Water Manger / Trough Etc. Size 36”X40” Poultry Farm:-A Model Poultry Farm Showing Brooder With Guard And Saw Dust Scattered On The Floors, Rearing House With Water Fountain. Laying Houses Furnished With Perches, Egg Nests And Automatic Feeder Etc. Complete Clean And Hygienic Surroundings 20” X 28”., Poultry House: - Up-To- Date Model Showing Perches, Egg Nests, Ghara, Kunali And Automatic Feeder With Open Yard, Size20” X 28”. 22. Kg-1-7322 Digital Audio Recording Unit With Accessories And Software • Computer – Apple Macbook Pro M1 Chip With 8 Core Cpu And 8 Core Gpu Mac Os Laptop ( 8Gb Ram, 256Gb Ssd, 13 Inch ) • Daw – Avid Media Composer 8 Educational Software Annual Subscription For Student, Download • Audio Interface – Mackie Onyx Artist 1-2 2X2 Usb Audio Interface. High-Resolution 2 In X 2 Out 24-Bit / 192Khz Recording. Music Production Software Included • Microphones – 1 Lapel Microphone, 1 Unidirectional Dynamic Microphone, 1 Head Phone. • Studio Monitor – Yamaha Hs8 Studio Monitor, 120 Watts Speaker. • Sufficient Cables ( All Inclusive For The Set ) • Microphone Stands – 1 Table Top. 1 Standing • Compatible Pop Filter 23. Kg-2-7323 Veterinary Specific ( Large Animal ) Anaesthesia System Vapourizer: Isoflurance And Sevoflurance For Anaesthesia In Large Ruminants And Equines. Bellows : 18 Ltrs Ascending, With Large Animal Absorber Circuit, Flow Rate Adjustable To 0-600 Lpm With Expandable Range Of Flow Rate Selectivity. Pneumatic Manual Push Button For Inspiration. Electric Outlets With Search Protection. Breathing Circuit-Included. Controls :Inspiratory Time 1-3 Sec Inspiratory Flow 10-650 Inspiratory Pressure 10-70 Cm H2o, Inspiratory Rate 2-80Bpm. Ventilator: True Microprocessor Technology Based Electronic Control System Incorporating The Feature Of Current Intensive Care Ventilator. Time Cycle And Pressure Limited Led Display Of Selected Respiratory Variables , Inspiration Time, Bpm And I: E Ratio. Alarms: Failure To Cycle And System Failure Visual And Audio Alaram. Multiple Electrical Outlet With Surge Protection. Over Pressure Governor 80Cm H2o. Gas Scavenger 19Mm Port. Soda Lime Canister: Quick Change. Rebreathing Bag : 30 Ltr X Two Bags And 15 Ltr X 1 Bag. Should Be Supplied With Multiparameter Monitor: Atleast 12 Inch, High Resolution Colour Tft Lcd Display Having Graphical And Tabular Trends Recording With Veterinary Specific Probes ( Atleast 4 Mtr Length For Each And All Sized ) For Spo2 , Etco2, Respiration, Ecg ( Waveform Disclosure And Arrhythmia Recall ) , Nibp ( Trend Readings ) And Temperature With Alarm Recall, Event Storage And Printer. Should Be Supplied With Emergency Crash Cart Trolley: With Mounting Rail And Additional Shelves For Monitor, Et Tubes And Emergency Drugs To Be Placed. Should Be Supplied With Endotracheal Tubes ( Cuff ) : 18Mm, 20Mm, 22Mm And 24Mm Dia. Should Be Supplied With Jumbo Oxygen Cylinders: 46 Ltrs Water Capacity ( Two In Number ) With Regulators And Tubings And Trolley For Transport. Should Be Supplied With Mouth Gag: ( Buttler / Gunthers ) : Two In Number For Cattle Use. Maintenance And Service:Five Years Warranty With All Services And Replacement Included. Anesthesia Machine, Monitor And Ventilator System Should Be Brand New. The Company Should Enclose A Letter From The Manufacturer That The Anesthesia Machine And Ventilator System Are Not Refurbished / Reconfigured And Are Brand New Machines. Letter Of Authority From The Principle Manufacturing Company Should Be Enclosed With Tender. Quoted Company Should Have Minimum Three Installations In Veterinary Institution ( Listed With Address Of Institutes And Satisfactory Reports ) .
|