|
Toilet Paper, Polypropylene Coupling D 50 Mm, Polypropylene Coupling D 110 Mm, Polypropylene Plug D 50 Mm, Polypropylene Plug D 110 Mm, Pipe Clamp (Metal) F 50, Copper Cable Vvgng-Ls 2X1.5 Gost-22483-77, Copper Cable Vvgng-Ls 2X2.5 Gost-22483-77, Household Gloves, Paper Towels 2 Ply, 2 Rolls, White, Polyvinyl Chloride (Pvc) Thermoplastic Welding Cord (Rod) For Hot Welding Of Joints (Seams) Of Commercial Homogeneous And Heterogeneous Floor Coverings. Designed To Create A Sealed, Waterproof And Wear-Resistant Monolithic Joint In The Premises Of Educational Institutions.2. Technical And Geometric Parameters• Material: Plasticized Polyvinyl Chloride (Pvc), Compatible In Composition And Melting Point With Commercial Linoleum.• Section Shape: Round (Iso 1923 Standard).• Cord Diameter: 4.0 Mm (Tolerance ±0.1 Mm).• Delivery Form (Winding In A Coil): 50 Linear Meters Or 100 Linear Meters (Depending On The Manufacturer).• Welding Temperature: 350–400 °C.• Color: Selected To Match (According To The Manufacturers Catalog Of Articles Of The Selected Linoleum Collection).3. Operational Requirements • Tightness And Strength: After Cooling And Cutting Off Excess, The Cord Must Form An Even Seam Flush With The Floor Surface, Preventing Moisture And Dirt From Getting Under The Coating.• Wear Resistance And Chemical Resistance: Resistance To Abrasion, Mechanical Stress And Regular Wet Cleaning Using Detergents And Disinfectants.• Fire Safety: Low-Flammability, Meets Fire Safety Requirements For Use In Public And Educational Institutions As Part Of Flooring Class Km2., Roll Commercial Polyvinyl Chloride (Pvc) Floor Covering, Heterogeneous, Wear-Resistant, Low-Flammability. Designed For Installation Of Floors In Classrooms, Corridors, Recreation Areas And On Evacuation Routes Of Educational Institutions.2. Regulatory Framework And Standards• Quality Standard: Gost 18108-2016 (Polyvinyl Chloride Floor Coverings. General Technical Conditions).• Fire Safety: Compliance With The Requirements Of The Technical Regulations Of The Eurasian Economic Union Tr Eaeu 043/2017.3. Geometric Parameters Of The Roll• Roll Width: 3.0 M (Width Tolerance According To Gost 18108-2016).• Roll Length (Standard Winding): 20 Linear Meters (60 M² In One Roll; Factory Winding Of 20–23 Linear Meters Is Allowed).• Total Coating Thickness: Not Less Than 2.0 Mm.• Thickness Of The Protective (Working) Layer: Not Less Than 0.7 Mm.Operational And Physical-Mechanical Indicators• Application Class (Wear Resistance): Not Lower Than 34 / 43 (According To En Iso 10874 / Gost 11529-2016).• Additional Protective Coating: Polyurethane Layer (Pur) To Facilitate Wet Cleaning And Protect Against Abrasion.• Abrasion Group: T (Highest, According To En 660-2).• Residual Deformation (Indentation): No More Than 0.10 Mm (Resistance To Desk And Chair Legs).• Color Fastness: Not Lower Than 6 Points (According To Iso 105-B02).• Antibacterial Properties: Presence Of Antibacterial And Antifungal Treatment.• Slip Resistance: Class R9 Or R10.5. Fire Danger Indicators (Class Km2)• Fire Hazard Class: Km2 (G1 - Low-Flammable According To Gost 30244-94; B2 - Moderately Flammable According To Gost 30402-96; Rp1 - Non-Flammable According To Gost R 51032-97; D2 - Moderate Smoke-Generating Ability And T2 - Moderately Hazardous In Toxicity According To Gost 12.1.044-89, Roll Commercial Polyvinyl Chloride (Pvc) Floor Covering (Homogeneous Or Heterogeneous), Wear-Resistant, Low-Flammability Class Km2 With Wear Resistance 34/43, Roll Width 2.5 M (One Roll 20 Running Meters, 50 Sq. M). Designed For Installation Of Floors In Rooms With High Traffic Intensity (Classrooms, Recreation Areas, Corridors And Evacuation Routes In Educational Institutions).Regulatory Framework And Standards Quality Standard: Gost 18108-2016 (Polyvinyl Chloride Floor Coverings. General Technical Conditions) Fire Safety: Compliance With Technical Requirements. Regulations Of The Eurasian Economic Union Tr Eaeu 043/2017. Technical And Operational Indicatorsapplication Class (Wear Resistance): Not Lower Than 34 / 43 (According To En Iso 10874 / Gost 11529-2016). Total Coating Thickness: Not Less Than 2.0 Mm. Thickness Of The Protective (Working) Layer: At Least 0.7 Mm (For Heterogeneous) Or 2.0 Mm Over The Entire Thickness (For Homogeneous). Additional Protective Coating: Polyurethane Layer (Pur) To Facilitate Cleaning And Protect Against Abrasion. • Abrasion Group: T (Highest, According To En 660-2).Residual Deformation (Indentation): No More Than 0.10 Mm (Resistance To Desk And Chair Legs).Resistance To Furniture Legs And Roller Chairs: High (No Damage Or Delamination).Color Fastness: Not Lower Than 6 Points (According To Iso 105-B02) Antibacterial Properties: The Presence Of Antibacterial And Antifungal Treatment.Slip Resistance: Class R9 Or R10.Fire Danger Indicators (Class Km2)The Material Must Have A Confirmed Fire Hazard Class Km2 With The Following Indicators: Flammability Group: G1 (Low-Flammable According To Gost 30244-94) Flammability Group: B2 (Moderately Flammable According To Gost 30402-96). Flame Propagation Group: Rp1 (Non-Flame Propagation According To Gost R 51032-97). Smoke-Forming Ability: D2 (Moderate According To Gost 12.1.044-89). Toxicity Of Combustion Products: T2 (Moderately Hazardous According To Gost 12.1.044-89)., Polypropylene Pipe D= 110 Mm, S= 18.3 Mm, Reinforcement: Fiberglass, Elbow Sewer Outlet, Polypropylene, Diameter 50 Mm, Bending Angle: 30°, Elbow Sewer Outlet, Polypropylene, Diameter 110 Mm, Bending Angle: 30°, Polypropylene Tee, Diameter 110 Mm/87°/30°, Polypropylene Tee, Diameter 110 Mm/50°/87°/30°, Transition Cast Iron-Plastic Diameter 110 Mm/124
|