|
procurement of certified reference materials (crms) for three years (2027-2028;2028-2029 & 2029-2030) , crm-biochemicaloxygendemand-water1000ppm (i) traceable to nist, ukas with coq including uom (ii) test method : is 3025(p:44) (iii) nominal value : 1000ppm(approximate) (iv) pack size : 100 ml minimum , crm-chemicaloxygendemand water base 500ppm i) traceable to nist, ukas with coq including uom ii)test method : is 3025(p:58) iii) nominal value : 500ppm(approximate) (iv) pack size : 100 ml minimum , crm-oil & grease in water 1000 ppm i) traceable to nist, ukas with coq including uom ii) test method : is 3025(p:39) (iii) nominal value : 1000 ppm(approximate) (iv) pack size : 100 ml (minimum) , crm -solid standards - tds- 500ppm (i) traceable to nist, ukas with coq including uom ii) test method : is 3025(p:17) iii) concentration : total solids :1000 ppm, ppm(approximate) pack size : 100 ml minimum , crm- ph buffers (i) traceable to nist, ukas with coq including uom ii) test method : is 3025(p:11) iii) each crm(1000 ml minimum) iv) nominal value a)buffer with ph:: 4.0 b)buffer with ph:: 7.0 and c) buffer with ph :: 9.2 , crm - conductivity,water,low100µs/cm (i) traceable to nist, ukas with coq including uom ii) test method : is 3025(p:14) iii) concentration : 100 µs/cm iv) pack size 100 ml minimum , crm- phenol in water 500 ppm i) traceable to nist, ukas with coq including uom (ii) details of uncertainty of measurement (iii) test method : is 3025(p:43) (iv) concentration : 500 ppm(approximate) v) pack size : 100 ml minimum , silica standard: sio2 @ 1000 ppm in h2o matrix, i) traceable to nist, ukas with coq including uom ii)concentration – 1000 ppm, iii) pack size : 100 ml minimum , silica standard: sio2 @ 100 ppm in h2o matrix, i) traceable to nist, ukas with coq including uom ii)volume – 100 ml minimum , standard: iron @ 100 ppm in h2o matrix, i) traceable to nist, ukas with coq including uom ii)concentration – 100 ppm, pack size – 100 ml minimum , piona complete standard as per astm d 6730, consisting of paraffins, isoparaffins, olefins, naphthene, aromatics, pack size – 1 x 1.0 ml or 4x0.1 ml minimum traceable to nist, ukas with coq including uom , piona complete standard as per astm d 6730 consisting of paraffins pack size – 1 x 0.1 ml minimum traceable to nist, ukas with coq including uom , (i) traceable to nist, ukas with coq including uom ii) test method : is 1448(p:118)/astm d 1840. iii) value : 1.5-2.0 % v/v iv) pack size : 3x 20 ml (minimum) , (i) traceable to nist, ukas with coq including uom ii)test method : astm d 97 / 5950. iii) pack size : 250 ml minimum (iv) pour point : (-) 6.0 or (-9) deg.c , (i) traceable to nist, ukas with coq including uom ii)test method : astm d 323 iii) nominal pressure : 0.6 kg/cm2(approx). pack size : 250 ml or 500 ml , i) traceable to nist, ukas with coq including uom (ii) test method : ip:342 iii) range: 1-10 ppm (approximately) iv) pack size : 250 to 500 ml , (i) traceable to nist, ukas with coq including uom (ii) test method :astm d3606 iii) concentration : set of certified reference materials for calibrating gas chromatograph as per astm d 3606 with benzene nominal concentrations with volume% viz. 0.06, 0.12, 0.33, 0.67, 1.25, 2.5 and 5.0 with methyl ethyl ketone as internal standard / set. each crm shall be in 2 ml ampoules x 7 (minimum) , crm - system calibration standard for poly aromatic hydrocarbon analyzer (i) traceable to nist, ukas with coq including uom ii) test method : ip391/astm d6591 (iv) concentration : set of certified reference materials for calibrating hplc as per astm d6591/ip391 containing following components: hexamethylbenzene, naphthelene, dibenzothiophene, 9-methylanthracene, 1-phenyldodecane, o-xylene, hexadecanoic acid methyl ester, octadecanoic acid methyl ester, oleic acid methyl ester, linoleic acid methyl ester, linolenic acid methyl ester, chrysene. each crm shall be in 2 ml ampoules , (i) traceable to nist, ukas with coq including uom ii) test method : astm d4815 iii) concentration : set of certified reference materials for calibrating gas chromatograph as per astm d4815 with mek concentrations with mass% viz. 0.1, 0.5, 2, 5, 10, 15 and 20 with atleast 1. ethanol 2.dimethyl ether 3. methyl t-butyl ether as internal standard / set. each crm shall be in 2 ml ampoules. , (i) traceable to nist, ukas with coq including uom ii) test method : astm d6591 /ip391 iii) concentration : set of four certified reference materials for calibrating hplc as per astm d6591/ip391 with following components per set a) o-xylene (concentration 40, 10, 2.5 and 0.5 mg/ml appx), b)fluorene (concentration 20, 10, 2.5 and 0.2 mg/ml appx) c)phenanthrene (concentration 4, 2, 0.5 and 0.1 mg/ml appx) each crm shall be in 1 ml ampoules , (i) traceable to nist, ukas with coq including uom ii) test method : astm d 7153. iii) value : (-) 50 deg.c(approx.) iv) pack size : 250 ml to 500 ml , i) traceable to nist, ukas with coq including uom ii)test method : astm d 1298 or is 1448(p:16) iii) range : 0.74-0.82 gm/cc iv) pack size : 250 ml to 500 ml , crm density high i) traceable to nistor npl (ii) details of uncertainty of measurement ii) test method : astm d 1298 or is 1448(p:16) iii) range : 0.82-0.86 gm/cc pack size : 250 ml to 500 ml , traceable to nist or npl(ii) details of uncertainty of measurement ii) test method: astm d445 iii) viscosity range:1.0-3.0 cst (approximately)@40°c pack size : 250 ml to 500 ml , traceable to nist, ukas with coq including uom(iii) test method: astm d92 (iv) range: 260 degc (approximately),pack size : 250 ml (minimum) , (i) traceable to nist, ukas with coq including uom(iii) test method: astm d93(iv) range: 140 degc (approximately) pack size : 250 ml (minimum) , motor gasoline distillation standard. (i) traceable to nist, ukas with coq including uom(iii) test method : is1448, p:18/astm d86 pack size : 250 ml (minimum) , distillation standard for kerosene oil. (i) traceable to nist, ukas with coq including uom(iii) test method : is1448, p:18/astm d86pack size : 250 ml (minimum) , distillation standard for diesel oil. (i) traceable to nist, ukas with coq including uom(iii) test method : is1448, p:18/astm d86 pack size : 250 ml (minimum) , (i) traceable to nist, ukas with coq including uom(iii) test method : is1448, p:20 (iv) range: 38-45 degc pack size : 250 ml (minimum) , (i) traceable to nist, ukas with coq including uom(iii) test method : astm d 156, is 1448(p:14)(iv) colur : + 25 pack size : 250 ml (minimum) , (i) traceable to nist, ukas with coq including uom(iii) test method : astm d 156, is 1448(p:14)(iv) colur : + 12 pack size : 250 ml (minimum) , i) traceable to nist, ukas with coq including uom(iii) test method : astm d1500(iv) concentration : astm colour 0.5 - 2.5 pack size : 250 ml (minimum) , (i) traceable to nist, ukas with coq including uom (ii) nominal valu : lovibond 4.0 y (approximately) (iii) pack size : 250 ml-500ml , (i) traceable to nist, ukas with coq including uom (iii) nominal value : lovibond 2.0 y (approximately) (iii) pack size : 250 ml-500ml , calibration set for astm d6366 - total trace nitrogen and its derivatives in liquid hydrocarbons by oxidative combustion and electrochemical detection. matrix: nitrogen (from pyridine) in p-xylene/toluene/ isooctane sets of 2 ml per ampoule. nominal concentration 0.1, 0.5, 1.0, 2.5, 5.0, 10 (mg/kg). traceable to nist, ukas with coq including uom. , cloud point reference materials as per astm d2500.pack size : 250 ml, minimum nominal value =(-) 5°c. traceable to nist, ukas with coq including uom , (i) traceable to nist, ukas with coq including uom test method : astm d4294.certified reference fuel for sulfur prepared in light mineral oil. each crm(100 ml) with approximate concentration as mentioned below:(i)crm-blank(zero), mg/kg(ii) crm-50, mg/kg(iii) crm-100, mg/kg(iv) crm-200, mg/kg(v) crm-300, mg/kg(vi) crm-400, mg/kg and(vii) crm-500, mg/kg (viii) crm-800, mg/kg(ix) crm-1000, mg/kg(x) mineral oil, white(mow),acs reagent grade containing less than 2 mg/kg sulfur or other suitable base material containing less than 2 mg/kg sulphur. , crm- sulphur in isooctane-toluene (i) traceable to nist or ukas (ii) details of uncertainty of measurement (iii) test method : astm d 5453 certified reference fuel for sulphur prepared in isooctane-toluene(ratio 3:1). each crm(100 ml) with approximate concentration as mentioned below (i) crm)-blank(zero), mg/kg 100 ml 1 bottle (ii) crm-1.0, mg/kg 100 ml 2 bottles (iii) crm-3.0, mg/kg 100 ml 2 bottles (iv) crm-5.0, mg/kg 100 ml 2 bottles (v) crm-7.5, mg/kg 100 ml 1 bottles (vi) crm-10.0, mg/kg 100 ml 1 bottle (vii) crm-12.5, mg/kg 100 ml 1 bottle , (i) traceable to nist, ukas with coq including uom ii)test method : astm d-97 / d-5950. (iv) pour point : (-) 30.0± 3.0deg.c (v) pack size : 250 ml (minimum) , traceable to nist or npl (ii) details of uncertainty of measurement iii) test method: astm d445 iii) viscosity range:.2.0-5.0 cst (approximately)@minus 20°c iv) pack size : 250 ml (minimum) , smoke point reference materials as per is 1448(p:31) / astm d-1322.pack size : 250 ml minimum. nominal value 17mm. traceable to nist,ukas with coq including uom , smoke point reference materials as per is 1448(p:31) / astm d-1322.pack size : 250 ml minimum. nominal value 20mm. traceable to nist, ukas with coq including uom , smoke point reference materials as per is 1448(p:31) / astm d-1322.pack size : 250 ml minimum. nominal value 22mm. traceable to nist, ukas with coq including uom , lead in gasoline (0.000, 0.100, 1.000, 2.000, 3.000,4.000, 5.000 g/ga),100 ml each , sulfur in 60% iso-octane/40% toluene(blank, 0.5, 1.0, 1.50, 2.0 mg/kg), 50 ml each , liquid chlorine standard of 1,2,4-trichlorobenzene in p-xylene (0.0; 0.5; 1.0; 1.5; 2.0; 5.0; 10.0) in mg/kg, 100 ml each. , certified reference materials of cold filter plugging point (cfpp) as per astm d6371 for diesel fuel. pack size : 250 ml, minimum nominal value =(-) 5 c to = (-) 10 °c (approx). traceable to nist, ukas with coq including uom.
|