Tenders Are Invited For Laboratory, Optical And Precision Equipments (Excl. Glasses) – Delivery Of A Micropl ... in Poland
Tender Notice
TenderID
120717389
Tender Brief
Tenders Are Invited For Laboratory, Optical And Precision Equipments (Excl. Glasses) – Delivery Of A Microplate Reader With Software To The Institute Of Agrophysics. Bohdan Dobrzański Pan In Lublin
Laboratory, Optical And Precision Equipments (Excl. Glasses) – Delivery Of A Microplate Reader With Software To The Institute Of Agrophysics. Bohdan Dobrzański Pan In Lublin. 1. The Subject Of The Order Is The Supply Of A Microplate Reader With Software To The Institute Of Agrophysics. Bohdan Dobrzański Pan In Lublin. 2. The Scope Of The Order Includes The Delivery To The Ordering Party Of A Microplate Reader With Software For The Institute Of Agrophysics. Bohdan Dobrzański Pan In Lublin. 3. A Detailed Description Of The Subject Of The Order Is Included In Annex No. 1 To The Swz. No. Required Parameters - Minimum Microplate Reader With Software 1. Reader Capable Of Reading Absorbance, Fluorescence And Luminescence (After Expansion) Necessary Condition 2. Detection Methods: - Absorbance With A Light Source - Xenon Uv Lamp - Fluorescence From The Top And Bottom With Trf - Luminescence - Fluorescent And Flash - Expansion Option Necessary Condition Absorbance Measurements - Monochromator Necessary Condition 3. Full Range Of Absorbance Wavelength: From Min. 230 Nm To 999 Nm Necessary Condition 4. Ability To Work With Various Plate Formats: 6 To 384-Well Necessary Condition 5. Bandwidth: Excitation < 5 Nm For Λ ≤ 315 Nm And < 9 Nm For Λ>315 Nm, Necessary Condition 6. Wavelength Accuracy: <+- 0.5 Nm For Λ > 315 Nm; <+- 0.3 Nm For Λ ≤ 315 Nm Necessary Condition 7. Wavelength Reproducibility <+- 0.5 Nm For Λ > 315 Nm; <+- 0.3 Nm For Λ ≤ 315 Nm Necessary Condition 8. Measuring Range Min. From 0 To 4 Od Necessary Condition 9. Reading Time Of A 96-Well Plate: Maximum 20 Seconds Necessary Condition 10. Possibility Of Being Equipped With A Module For Measuring Samples From Micro-Volumes In A Quartz Plate - At Least 16 Simultaneous Quantitative And Qualitative Measurements Of Dna, Rna And Protein Concentrations From An Amount Of At Most 2 Μl, With A Detection Limit Of 1 Ng/Μl. Fluorescence Measurements Are Also Possible. Additional Condition Note! Bid Evaluation Criterion 11. Absorbance Scan In The Full Range Necessary Condition Fluorescence Measurements - Monochromators Necessary Condition 12. Full Range Of Fluorescence Reading: Excitation At Least: 230-850 Nm, Emission 280-850 Nm, Trf Measurement Not Worse Than 90Amol/Well - 384-Well Plate Necessary Condition 13. Reading Sensitivity Fluorescence Not Worse Than 170 Amol/Well For A 384-Well Plate For Reading From Above And 9 Fmol/Well For Reading For A 96-Well Plate For Reading From Below Necessary Condition 14. Device With The Possibility Of Automatic Selection Of The Focusing Height Of The Light Beam Falling On The Sample In The Z (Vertical) Plane With Automatic Background Correction Necessary Condition 15. Possibility To Perform A Full Excitation And Emission Scan Scope Necessary Condition Luminescence Measurement - Expansion Option Necessary Condition 16. Possibility Of Expansion With A Module For Luminescence Measurements. Flash Luminescence Sensitivity Not Worse Than 12 Amol Atp/Well, Fluorescent Luminescence Sensitivity Not Worse Than 225 Amol Atp/Well, Dynamic Range Not Worse Than 8 Decades, Wavelength Range Not Worse Than 380-600 Nm Necessary Condition Other Modules 17. Built-In Plate Shaker With
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 120717389
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.