Tender for Procurement Of Transformer Wti/Oti For Local And Ccu Transmitter Along With Rtd For Remote Indication Of Wti & Oti For Ph-Iv, Stps, Mppgcl, Sarni , Wti (Winding Temperature Indicator ) , Wti For 315 Mva Bhel Make Generating Transformers Range - 30°C - 150°C , (A) Wti For 315 Mva Bhel Make Generating Transformers Range - 30°C - 150°C & Wti Ctr - Hv -456/3.2-2.8-2.3, Oil/Wdg Temp Rise - 35/40°C Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , (B) Wti For 315 Mva Bhel Make Generating Transformers Range - 30°C - 150°C & Wti Ctr - Lv - 12000/5A, Oil/Wdg Temp Rise - 35/40°C Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 20 Mva Bhel Make Unit Auxiliary Transformers Range - 30°C - 150°C Wti Lv Ctr -799.81/2.38-2.72-2.94-3.4-3.68 Oil/Wdg Temp Rise - 50/55°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 50 Mva Bhel Make Station Transformers Range - 30°C - 150°C Wti Ctr - Hv -81/2.8-2.4-2.0A, Lv1&2 - 2092/3.4-3.0-2.6A,Oil/Wdg Temp Rise - 50/55°C Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 50 Mvar Areva Make Sarni Astha Reactor Range - 0°C - 150°C, Wti Ctr - 70/2 A, Oil/Wdg Temp Rise - 50/55°C Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 2000 & 1600 Kva Voltamp Make Ahp & Esp Transformers Range - 0°C - 150°C, Wti Ctr - 2135/5A, Oil/Wdg Temp Rise - 50/55°C, Control Switch 02 Nos. & 05 Meter Capillary Length , Wti For 800 & 750 Kva Voltamp Make Etp & Ahp Transformers Range - 0°C - 150°C, Wti Ctr - 1070/5A, Oil/Wdg Temp Rise - 50/55°C, Control Switch 02 Nos. & 05 Meter Capillary Length.. , Wti For 250 Kva Voltamp Make Raw Water Intake Transformers Range - 0°C - 150°C, Wti Ctr - 335/5A, Oil/Wdg Temp Rise - 50/55°C, Control Switch 02 Nos. & 05 Meter Capillary Length.. , Wti For 50 Mvar Ge Make Isp Reactor Range - 0°C - 150°C, Wti Ctr - 70/2.0-1.5-1.0 A, Oil/Wdg Temp Rise - 45/50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 63 Mvar Bhel Make Bus Reactor-I Range - 0°C - 150°C, Wti Ctr - 87/2.2-2.0-1.8-1.6 A, Oil/Wdg Temp Rise - 50/55°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 63 Mvar Bus Reactor-Ii Range -30°C - 150°C, Wti Ctr - 87/2.2-2.0-1.8-1.6 A, Oil/Wdg Temp Rise - 45/50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , Wti For 315 Mva Bhel Make Inter Connecting Transformer (Ict) , (A) Wti For 315 Mva Bhel Make Inter Connecting Transformer (Ict) , Range - 30°C - 150°C & Wti Ctr - Hv - 455/2.5-2.0-1.5 A, Oil/Wdg Temp Rise - 40/45°C , Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , (B) Wti For 315 Mva Bhel Make Inter Connecting Transformer (Ict) Range - 30°C - 150°C & Wti Ctr - Iv - 919/2.9-2.5-2.1 A Oil/Wdg Temp Rise - 40/45°C , Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. , ( C ) Wti For 315 Mva Bhel Make Inter Connecting Transformer (Ict) Range - 30°C - 150°C & Wti Ctr - Lv - 1837/3.0-2.7-2.4 A, Oil/Wdg Temp Rise - 40/45°C , Over Ambient Of 50°C, 04 Micro Switches, 10 To 12 Meter Capillary Length , Oti (Oil Temperature Indicator ) , Oti For Ht Transformers / Reactor Range - 20°C - 140°C 02 Micro Switches, 10 To 12 Meter Capillary Length (For Gt, St , Uat, Bus Reactor- 1 & 2) , Oti For Ht Transformers / Reactor Range - 0°C - 150°C,02 Micro Switches, 10 To 12 Meter Capillary Length. ( For Ashta Line And Isp Reactor ) , Oti For Lt Transformers Range - 0°C - 150°C, Control Switch 02 Nos & 05 Meter Capillary Length. ( For Ahp, Esp, Esp Tr Set, Etp, Rw Intake Transformers ) , Oti For Ht Transformer Range - 20°C - 140°C, 04 Micro Switches, 10 To 12 Meter Capillary Length. ( For ,Inter Connecting Transformer (Ict) ) , Ccu With Inbuilt Power Supply / Transmitter Along With Rtd (Pt 100) For Remote Indication Of Wti & Oti , Ccu For 315 Mva Bhel Make Generating Transformers , (A) Ccu For 315 Mva Bhel Make Generating Transformers Range Wti- 30°C - 150°C & Wti Ctr - Hv -456/3.2-2.8-2.3, Oil/Wdg Temp Rise - 35/40°C Over Ambient Of 50°C. , (B) Ccu For 315 Mva Bhel Make Generating Transformers Range Wti- 30°C - 150°C & Wti Ctr - Lv - 12000/5A, Oil/Wdg Temp Rise - 35/40°C Over Ambient Of 50°C. , Ccu For 20 Mva Bhel Make Unit Auxiliary Transformers Wti Range - Wti- 30°C - 150°C Wti Lv Ctr --799.81/2.38-2.72-2.94-3.4-3.68, Oil/Wdg Temp Rise - 50/55°C. , Ccu For 50 Mva Bhel Make Station Transformers , (A) Ccu For 50 Mva Bhel Make Station Transformers Wti Range - Wti- 30°C - 150°C - Hv -81/2.8-2.4-2.0, Oil/Wdg Temp Rise - 50/55°C Over Ambient Of 50°C , (B) Ccu For 50 Mva Bhel Make Station Transformers Wti Range - Wti- 30°C - 150°C - Lv1&2 - 2092/3.4-3.0-2.6A, Oil/Wdg Temp Rise - 50/55°C Over Ambient Of 50°C. , Ccu For 50 Mvar Areva Make Sarni Astha Reactor Range - Wti - 0°C - 150°C, Wti Ctr - 70/2 A, Oil/Wdg Temp Rise - 50/55°C Over Ambient Of 50°C. , Ccu For 50 Mvar Ge Make Isp Reactor Wti Range - Wti - 0°C - 150°C, Wti Ctr - 70/2.0-1.5-1.0 A, Oil/Wdg Temp Rise - 45/50°C. , Ccu For 63 Mvar Bhel Make Bus Reactor-I Wti Range - Wti - 0°C - 150°C, Wti Ctr - 87/2.2-2.0-1.8-1.6 A, Oil/Wdg Temp Rise - 50/55°C , Ccu For 315 Mva Bhel Make Inter Connecting Transformer (Ict) Range Wti- 30°C - 150°C , (A) Ccu For 315 Mva Bhel Make Inter Connecting Transformer (Ict) Range Wti- 30°C - 150°C & Wti Ctr - Hv - 455/2.5-2.0-1.5 A, Oil/Wdg Temp Rise - 40/45°C Over Ambient Of 50°C. , (B) Ccu For 315 Mva Bhel Make Inter Connecting Transformer (Ict) Range Wti- 30°C - 150°C & Wti Ctr - Iv - 919/2.9-2.5-2.1 A Oil/Wdg Temp Rise - 40/45°C Over Ambient Of 50°C. , (C) Ccu For 315 Mva Bhel Make Inter Connecting Transformer (Ict) Range Wti- 30°C - 150°C & Wti Ctr - Lv - 1837/3.0-2.7-2.4 A, Oil/Wdg Temp Rise - 40/45°C Over Ambient Of 50°C. , Ccu For Oti , (A) Ccu For Oti Range - Oti- 20°C - 140°C, Input From Pt100 Sensor Dual 4 - 20 Ma Dc Output Signal (For Gt, Uat, St & Ict ) , (B) Ccu For Oti Range - Oti- 0°C - 150°C, Input From Pt100 Sensor Dual 4 - 20 Ma Dc Output Signal (For Sarni- Ashta & Isp Reactor) , Transformer Protection System / Relay For 2 Mva Dry Type Transformer Having Winding Temperature Scanner 4 Channels With 4-20 Ma Dc Output Suitable For Auxiliary Supply 90-260 V Ac/Dc, Range - 0-300°C, 4Nos. Pt-100 Sensor With 5 Meters Cable Length
|