Tender For Sealed Quotations Are Invited For Providing Material/Services Including Consumable Material With Installation Work For Biomedical Laboratory, Instrumentation And Control Engg. Department. D.O Sensor & Transmitter: Annexure A Sensor - Measuring Principle- Fluorescence Measurement Method, Measuring Range O2Omg/L (0-200% Saturation), Measurement Deviation - +3%Fs; ±0.5C (25C), Resolution- 0.01Mg/L: 0.1%: 0.1°C, Waterproof Level-Ip68, Electrode Wire Lengtn Default 5M, Shell Material- Corrosion Resistant Plastic, Stainless Steel Transmitter - Input :- From Do Sensor (Fluorescence Type) Display:- Lcd Display, Range:- Programmable As Per Sensor Consumable List Item Relay:- 2 Nos. Retransmission: - 4-20 Ma Ph Sensor & Transmitter: Communication:- Rs485 Modbus/Rs232/Gprs/Gsm/Rs422 Power Supply: 230 V Ac/24 V Dc Sensor: Measuring Range: 0-14, Zero Point: 7.00 + 0.25, Temperature Range: 0-80 °C, Pressure Range: 0.0--0.3 Mpa, Membrane Resistance:< 500 Ma, Reference System: Ag/Agci/Kci,Connection Method: Standard Configuration, 10 M, Installation Method: Submerged Type, Pipeline Type, Flow Type. Transmitter: Input :- From Ph Sensor Relay:- 2 Nos. Retransmission: - 4-20 Ma Communication:- Rs485 Modbus/Rs232 Power Supply: 230 V Ac/24 V Dc Chlorine Sensor & Transmitter - Sensor - Measuring Material: Double Platinum Ring /3 Electrodes, Shell Material: Glass + Pom, Waterproof Grade: Ip68, Measuring Range: 0-2 Mg/L; 0-10 Mg/L; 0-20 Mg/L, Measurement Accuracy: +1% F.S., Pressure Range: S 0.3 Mpa, Temperature Compensation: Ntc10K, Temperature Range: 0-80°C, Calibration: Sample Calibration, Chlorine-Free Water Calibration, Comparison Calibration, Connection Method: 4-Core Cable, Cable Length: Standard 10 M Cable; Optionally Extendable To 100 M Transmitter - Input: From Chlorine Sensor, Display: Lcd Display, Range: Programmable As Per Sensor, Retransmission: 4-20 Ma Dc, Communication: Rs-485 Modbus/ Rs-232 Turbidity Sensor And Transmitter Sensor - Measurement Mode: 90° Infrared, Material: Pom, Ip Grade: Ip65, Measurement Range: 0-1000 Ntu, Lower Limit: 0.1 Ntu, Accuracy: 0-100 Ntu: #2%; 100-1000 Ntu: ±5%, Pressure: S 0.2 Mpa, Temperature: 0-45°C, Calibration: Standard Or Sample Calibration, Cable Length: 1 M Or Customized Cod & Bod Sensor Transmitter - Input: From Turbidity Sensor, Display: Lcd Display, Range: Programmable As Per Sensor, Retransmission/ Output: 4-20 Ma Dc, Communication: Rs-485, Communication Protocols/ Interfaces: Modbus/Rs232 Cod Measuring Range: 0-500 Mg/L, Bod Measuring Range: 0-250 Mg/L, Cod/Bod Resolution: 0.1 Mg/L, Cod/Bod Accuracy: +5% F.S., Tss Measuring Range: 0-10,000 Mg/L, Tss Resolution: 0.1 Mg/L, Additional Measuring Range (As Printed): 0-200 Mg/L (The Source Labels This As Tss; Please Confirm Whether This Is Intended To Be Tds). Instrument Power Supply Voltage: 12-24 Vdc, Working Temperature: 0-40 °C, Working Pressure: < 0.1 Mpa Controller - Microprocessor Based, Communication Output: 1 X Rs-485 Analog Outputs: 6 X 4-20 Ma Outputs, Relay Outputs: 3 Relay Outputs Data Records: Historical Records, Display: 7-Inch Touch Screen.
|