Bids Are invited for Data Centre Infra And Managed O& ;M Services At C-Dot, Bangalore - Rmu/Vcb At Main Feed [Outdoor Rmu - Two-Way Outdoor Sf6 11Kv] , 11 Kv Ht Cable , Transformer , Ht Panels , Main Lt Panel , Dg Sets - Prime Rated , Dg Amf Panel With Change-Over , Critical Ups (Modular Live-Swappable 300 Kva) , Utility / Non-It Ups (30 Kva) , Battery – Li-Ion For Critical Ups (15 Min Backup) , Battery – Smf/Vrla For Utility Ups , Ups Input/Output Panels , Rack Pdu / Ipdu , Floor Pdu / Main Pdu , Isolation Transformer , Low-Side / Power Cabling , Pdu-To-Rack Cabling , Inrow Panel - Clc Dbs / In-Row Cooling Distribution Panel , Inrow Cooling – Dx Based (N+1) , Comfort Room Cooling (Split Acs N+1 With Auto-Sequence For Noc, Battery, Electrical/Ups & Bms Rooms Including Stabilizers & Low-Side Works) , Bms, Ibms Solutions And Its Integration , Cctv System , Fire Alarm/Detection System For Racks And Rooms (Including Vesda) , Fire Suppression (Fk-5-1-12) , Access Control System (Biometric + Rack-Level) , Water Leakage Detection System , Rodent Repellent System , Dcim Solution , Civil Works - Wall Opening & Closing, Wall Painting & Raised Floor Cut-Out, Glass Partitioning, Equipment Foundation Including Dg, Cable Routes, Deep Cleaning, Acp Cladding, Structural Glazing, Canopy, Entrance Arch, Planter Beds, Landscape, External Lighting, Hsd Tank Fencing Modification, Antistatic Vinyl Flooring, Insulation, Fire-Retardant Painting Etc. As Per Site Requirements , Noc Workstation Tables (With Drawers, Keyboard Tray, Cpu Rack & Raceways) , Bms Room Workstation Tables , High-Back Revolving Chairs , 65 Led Tvs (Wall-Mounted With Supports & Ups Power) , White Magnetic Boards (1050 Mm × 1200 Mm) With Accessories , Glow Signage (Push/Pull, Area Identification & Emergency Signs) , Public Address / Voice Evacuation System (Complete With 8-Zone Master Controller, Amplifiers, Microphones, Ceiling & Wall Speakers, Redundancy Loop) , Portable / Handheld Fire Extinguishers , Lightning Protection System (For Entire Data Centre + Transformer Yard) , Earthing & Equipotential Bonding System (Including Earth Pits, Inspection Chambers & Marking) , Rubber Mats (Is 15652) For Ht/Lt/Pdu Panels , Structured Cabling (Complete With Certification) , Cable Managers / Bus Bar Trunking , Distribution Boards (Raw Power Db, Ups Db, Cac Db, Clc Dbs) , Decommissioning, Uninstallation & Secure Shifting Of Existing Infrastructure , Statutory Approvals & Clearances (Peso, Pcb, Electrical Inspector, Fire Authority Etc.) , Training Materials / Handouts (For Up To 5 C-Dot Personnel) , Installation, A/T, Commissioning And Hand-Over , Engineering, Training, Documentation (Including As-Built Drawings, Sops, Pmps, O&M Manuals – Hard & Soft Copy) , Any Other Items Required As Part Of The Project , Tier Iii Standard Data Centre Certification (Tia 942C)
|