|
Bids Are invited for Excavation In Trenches N Exc 1.5 M Wide And N Exc 1.5 Mtr Deep In Soft Or Lose Soil For Taking Out Pipe And Laying Of Pipe And Getting Out For Diverting Of Ci Pipe Line , Returning Filling In Including Spreading Leveling Watering And Well Ramming In Layers N Exc 25 Cm Thick , Removal Of Excavated Soil To A Distance Not Exc 50 M And Depositing Where Directed At A Level Not Exc 1.5 Mtr Above The Starting Point , Taking Up Ci Or Di Water Main With Spigot And Socket Ends And Lead Joints Incl Burning Out And Recovering Lead From Pipe Of 100 Mm Bore - Taking Up Ci Or Di Water Main With Spigot And Socket Ends And Lead Joints Incl Burning Out And Recovering Lead From Pipe Of 100 Mm Bore For Relaying Of Serviceable Pipe After Cleaning , All As Per Here In Above But 150 Mm Bore , All As Per Here In Above But 200 Mm Bore , All As Per Here In Above But 250 Mm Bore , Relaying Of Di Or Ci Or Gi Pipe 100 Mm Bore In Trenches Over The Masonry Pillars After Cleaning Thoroughly Including Fittings , All As Per Here In Above But 150 Mm Bore , All As Per Here In Above But 200 Mm Bore , All As Per Here In Above But 250 Mm Bore , Mand L Di Pipe Of 100 Mm Bore With Spigot And Socket End Rubber Gas Cate Joint End With Bolted Joint Centrifugally Cast Class K 7 , All As Per Here In Above But 150 Mm Bore , All As Per Here In Above But 200 Mm Bore , All As Per Here In Above But 250 Mm Bore , Taking Up Or Down 80 Mm Bore Steel Tubing And Connection Including Cleaning For Relaying Or Removal To Store From Trenches Or Wall Surfaces , All As Per Here In Above But Bore Of Pipe 50 Mm , All As Per Here In Above But Bore Of Pipe 40 Mm , All As Per Here In Above But Bore Of Pipe 25 Mm , All As Per Here In Above But Bore Of Pipe 20 Mm , Relaying Or Refixing Old 80 Mm Bore Gi Tubing Or In Floor Or Pillar Or Wall In New Or Old Position , All As Per Here In Above But Bore Of Pipe 50 Mm , All As Per Here In Above But Bore Of Pipe 40 Mm , All As Per Here In Above But Bore Of Pipe 25 Mm , All As Per Here In Above But Bore Of Pipe 20 Mm , M And L 80 Mm Bore Gi Tubing Medium Grade In Trenches Or Floor Or Pillar And Connection In Old Or News Position Including Fitting Like Socket Union Tee Reducer Nipple , All As Per Here In Above But Bore 50 Mm , All As Per Here In Above But Bore 40 Mm , All As Per Here In Above But Bore 25 Mm , All As Per Here In Above But Bore 20 Mm , Taking Up Or Down Pvc Pipe Upto 50Mm Bore And Connection Including Cleaning For Relaying Or Removal To Store From Trenches Or Wall Surfaces , Relayin Re Fixing Pvc Pipe Upto 50Mm Bore In Floor Or Pillar Or Wall In New Or Old Position Including Fitting - Relaying/Re-Fixing Pvc Pipe Upto 50Mm Bore In Floor Or Pillar Or Wall In New Or Old Position Including Fitting , Supply And Laying Of Upvc Pipes 50 Mm Outer Dia Schedule 80 Having Thermal Stability For Hot And Cold Water Supply All Fittings Laid In Trenches , Supply And Laying Of Upvc Pipes 40 Mm Outer Dia Schedule 80 Having Thermal Stability For Hot And Cold Water Supply All Fittings Laid In Trenches , Supply And Laying Of Upvc Pipes 20 Mm Outer Dia Schedule 80 Having Thermal Stability For Hot And Cold Water Supply All Fittings Laid In Trenches , Supply And Laying Of Upvc Pipes 25 Mm Outer Dia Schedule 80 Having Thermal Stability For Hot And Cold Water Supply All Fittings Laid In Trenches , Supply And Fix Pvc Ball Valve Suitable For Upvc Pipe Line Any Type Any Size 40Mm Including Fittings If Required , Supply And Fix Pvc Ball Valve Suitable For Upvc Pipe Line Any Type Any Size 50Mm Including Fittings If Required , Supply And Fix Pvc Ball Valve Suitable For Upvc Pipe Line Any Type Any Size 20Mm Including Fittings If Required , Supply And Fix Pvc Ball Valve Suitable For Upvc Pipe Line Any Type Any Size 25Mm Including Fittings If Required , M And L Di Bend Any Type Radius And Angles Tappers And Type Straight Bend Increasing Decreasing Or Double Socket Etc Tee Pipes Single Branch Y Junction Double Branch , S And F 100 Mm Bore Sluice Valve With Spindle Iron Wheel Head And Both Ends Flanged And Ms Nut Bolts And Washers And Pair Of Rubber Or Fiber Gasket And Fixed In Position , All As Per Above Item But 150 Mm Bore , All As Per Above Item But 200 Mm Bore , All As Per Above Item But 250 Mm Bore , M And L For 50 Mm Bore Gate Valve Gum Metal Class-Ii Screwed Down High Pressure With Clutch Handle Screwed Both Ends For Iron Pipe Including Taking Out Of Old Unserviceable Gate Valve , All As Per Above Item But Size 40 Mm Bore , All As Per Above Item But Size 25 Mm Bore , All As Per Above Item But Size 20 Mm Bore , S And F For Straight Plain Brass Ferrules Or Connecting Screws Screwed Bolt Ends Of Size Upto 25 Mm Bore Pipe , M And L Pcc 1 4 8 Type D2 Using 40 Mm Graded Stone Aggregate As In Foundation Of Pillar , M And L Pcc 1 2 4 Type B-0 Using 12.5 Mm Graded Stone Aggregate As In Coping On Brick Machinary On Of Pillar , M And L For Mechanical Joint For Jointing Of Di Pipe Of Size Upto 150 Mm Including Excavation Removing Returning At Site , M And L For Mechanical Joint For Jointing Of Di Pipe Of Size Upto 250 Mm Including Excavation Removing Returning At Site , M And L For Brick Massonary Valve Pit With Brick In Cm 1 6 With 100Mm Thick Pcc Work 1 3 6 Type C2 From Fundation Over 75Mm Thick 15Mm - M And L For Brick Pit With Brick In Cm 1 6 With 100Mm Thick Pcc Work 1 3 6 Type C2 From Fundation Over 75Mm15mm
|