Bids Are invited for Sitc Of 1000 Kva Oil Type Transformer - Sitc Of 1000 Kva Bee 4 Star Rated , 11/415 V Step Down, 3 Phase, 50 Hz, Dyn 11 Vector Group, Oil Type Transformer. Detail In Specification And Atc , Sitc Of Lt Panel - Sitc Of Cubicle-Type Compartmentalised, Floor-Mounted Lt Panel Consists Of 01 No. 415 V, 2000 A Capacity Tin Plating Pure Copper Bus Bars, 2 No. 415 V, 50 Ka Fp Mdo Type Acb With Micro Processor Base As Incoming Arrangement And 10 Nos 415 V, 50 Hz, Fp, Mccb As Outgoing Arrangement. Detail In Specification And Atc , Supply And Delivery Ht Cable - Supply And Delivery Of Ht 11 Kv (E) Grade 3 Core 300 Sq. Mm Circular Armoured Al. Xlpe (E) Cable. , Supply And Delivery 4C Lt Cable - Supply And Delivery Of 4 Core 300 Sq. Mm Xlpe Insulated & Sheathed Armoured Aluminium Conductor Cable For Working Voltage Up To 1100 Volt. , Laying Of 3C Ht Cable - Laying Of One 3 Core 300 Sq. Mm Ht Cable Through Existing Covered Masonry Trench. , Supplying And Fixing Of Cable Termination - Supplying And Fixing Of 3 Core 300 Sq. Mm 11Kv Xlpe (E) Cable Termination Heat Shrinkable End Kit.Detail In Specification. , Supply And Delivery Single Core Lt Cable - Supply And Delivery Of 400 Sq. Mm Single Core Xlpe Insulated And Sheathed Armoured Aluminium Conductor Cable For Working Voltage Up To 1100 Volt. , Laying Of Single Core Lt Cable - Laying Of One No. 400 Sq. Mm Single-Core Cable Through An Open Masonry Trench. , Laying Of 4 Core Lt Cable - Laying Of One No. 4 Core 300 Sq. Mm Cable Through An Open Masonry Trench. , Supplying And Making End Termination And Gland For 4C 185Sqmm Cable - Supplying And Making End Termination With Brass Compression Gland For 4C 185Sqmm Cable. , Supplying And Making End Termination And Gland For 4C 300 Sqmm Cable - Supplying And Making End Termination With Brass Compression Gland For 4C 300 Sqmm Cable. , Supplying And Making End Termination And Gland For Single Core 400 Sqmm Cable - Supplying And Making End Termination With Brass Compression Gland For Single Core 400 Sqmm Cable. , 65Mm Dia Gi Pipe Earthing - Earthing With 65 Mm Dia Gi Pipe (Tata Medium)X3.0 Mts. Long. Detail In Specification. , 80 Mm Dia Gi Pipe Earthing - Earthing With 80 Mm Dia Gi Pipe (Tata Medium)X3.0 Mts. Long. Detail In Specification. , Masonry Enclosure On The Top Of The Earth Electrode - Extra For Providing Masonry Enclosure On The Top Of The Earth Electrode. Detail In Specification. , Treatment Of Soil By Using Salt And Charcoal - Extra Treatment Of Soil By Using Salt & Charcoal For Pipe Electrode. , 25Mmx 6Mm Earth Busber - Supply And Fixing Of Earth Busbar Of Galvanized (Hot Dip) Ms Flat 25 Mmx6 Mm On Wall. Detail In Specification. , Connecting The Equipment By 20Mmx3mm Ms Flat - Connecting The Equipment Body To Earth Bus Bar Including Supply And Fixing 20 Mmx3 Mm Galvanized (Hot Dip) Ms Flat On Wall/Floor. Detail In Specification. , 65Mmx 8Mm Earth Busber For Neutral Earthing - Supply And Fixing Earth Bus Bar Of Galvanized (Hot Dip) Ms Flat 65 Mmx8 Mm On Wall Having Clearance Of 6 Mm From Wall (For Neutral Earthing) . Detail In Specification. , Insulating The 65Mm X 8 Mm Gi Flat - Insulating The 65Mmx 8 Mm Gi Flat Incl. Supply And Fixing Black Heat Shrink Pvc Sleeves Etc . Detail In Specification. , Supplying And Laying 240 Sq. Mm. Single Core Flexible Cu Wire - Supplying And Laying 240 Sq. Mm. Single Core Multi Strand Pvc Insulated Flexible Cu Wire. Detail In Specification. , 65Mmx 8Mm Earth Busber - Supply And Fixing Earth Bus Bar Of Galvanized (Hot Dip) Ms Flat 65 Mm X 8 Mm On Wall Having Clearance Of 6 Mm From Wall . Detail In Specification. , 50Mmx 6Mm Earth Busber - Supply And Fixing Earth Bus Bar Of Galvanized (Hot Dip) Ms Flat 50 Mmx 6 Mm On Wall Having Clearance Of 6 Mm From Wall . Detail In Specification. , Charges For Dismantling - Charges For Dismantling Of The Existing 750 Kva Dry Type Old Transformer From The Existing Sub-Station Building, After Disconnection Existing Connection, Deposited The Same At Com And Jnmh Store, Mending The Damages As Per Direction. , Charges For Withdrawal And Relaying Of Existing Cable - Charges For The Necessary Withdrawal, Shifting, And Relaying Of Existing Ht And Lt Cables During Transformer And Lt Panel Installation, Inclusive Of Necessary Temporary Arrangements As Per The Direction Of Eic
|