Real-Time Polymerase Chain Reaction (Pcr) Equipment – Hochschule Reutlingen - Real-Time-Pcr-System (Qpcr-System). 1. Object Of Procurement A Plate-Based Qpcr System With At Least 96 Reaction Positions For The Quantitative Analysis Of Nucleic Acids Is To Be Procured. Systems In 96-Well Or 384-Well Formats Are Acceptable; A 384-Well Format Is Not A Minimum Requirement. 2. Area Of Application The System Is Used For Molecular Biology Applications, In Particular For The Analysis Of Gene Expression, For The Quantification Of Nucleic Acids And For Standardized Qpcr-Based Examinations In The Field Of Biomedical Research And Genomics. 3. Functional Requirements The System Must Be Particularly Suitable For: - Real-Time Pcr Measurements - Quantitative Gene Expression Analyzes (Rt-Qpcr) - Absolute And Relative Quantification Of Nucleic Acids - Melting Curve Analyzes - Multiplex Analyzes - Genotyping And Copy Number Variation (Cnv) Applications - Evaluation And Documentation Of The Measurement Results 4. Basic Technical Requirements A System With The Following Basic Properties Is Required: - Thermocycler Unit Suitable For The Intended Qpcr Applications - At Least 96 Reaction Positions Per Run; 96-Well And 384-Well Systems Are Permitted - Suitable Optical Detection System - Manufacturer-Validated Reaction Volume Range That Includes Reaction Volumes Of 10 Μl Or Less - Temperature Range At Least 4-99 °C; Temperature Accuracy And Uniformity At Most +/-0.5 °C Or Better - Maximum Ramp Rate At Least 2.5 °C/S - Fluorescence Detection With At Least Five Independently Usable Optical Channels Or Multiplex Detection Of At Least Five Targets Per Well - Support Of Intercalating Dye Chemistries (E.G. Sybr Green) And Hydrolysis Probes - Quantitative Linear Dynamic Range Of At Least 6 Log10 Levels - Standard Melting Curve Analysis - Hardware And Software For Measurement Control And Standard Data Analysis Including Cq/Ct Determination, Standard Curves As Well As Absolute And Relative Quantification - Export Of Measurement And Evaluation Data In Common Further Processable Formats - Regular Operation, Data Storage And Standard Data Analysis Without A Mandatory External Cloud Service Or Ongoing Cloud Subscription - Complete Suitability For Safe Routine Operation In University Research Laboratories 5. Scope Of Services The Scope Of Services Includes In Particular: - Free Delivery Point Of Use - Installation And Commissioning - Instruction And Training - Provision Of The Required Software Named In The List Of Services - Complete Technical Documentation - Ready-To-Use Handover 6. Special Information - Requirements For Calibration, Maintenance, Service, Software Maintenance And Required Consumables Must Be Stated In The Offer In Accordance With The Tender Documents. - On-Site Requirements Must Be Stated In Full.
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 119501033
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.