Bids Are invited for Rcc Foundation By Footing - Material Dash M20 Grade Rcc Typical Size By Thickness Approx 600 X 600 X 750 Mm Foundation Sized As Per Soil Condition And Wind Load , Pcc Layer - Material Pcc Typical Size 100 Mm Thick Tech Specification Dash Below Rcc Footing , Reinforcement - Material Tmt Steel Typical Size Dash 12Mm Mainby 8 Dash 10 Mm Distribution Tech Specification Spacing Cage To Structual Design , Anchor Bolts - Material Dash Gi By Hdg Typical Size Dash M16 By M20 Tech Specification Heavy Dash Duty Bolts With Nuts And Washers , Rcc Pedestal - Material M20 Rcc Typical Size Approx300 X 300 Mm Tech Specification Raised Pedestal Above Finished Ground Level , Main Pole - Material Ms By Gi Squre Pipe Typical Size 100 X 100 X 4 Mm Tech Specification Heavy Duty Single Pole Support , Base Plate - Material Ms Plate Typical Size 10-12 Mm Thick Tech Specification Approx 250 X 250 By 300 X 300 Mm Final Size By Engineer , Gusset Plate - Material Ms Plate Typical Size As Reqd Tech Specfication Strengthening Between Pole And Base Plate , Display Frame - Material Ms By Gi Squre Rectangular Pipe Typical Size 40 X 40 2 Mm Or 50 X 25 X 2 M Tech Specification Frame Fabricated To Display Dimensions , Display Unit - Material Led Digital Signage Typical Size As Per Approved Design Tech Specification Secure Mounted With Service Access , Acp Clading - Material Exterior Grade Acp Typical Size 3 Mm Tech Specification Clading On Pole And Structual Frame , Acp Border Bording - Material Acp Folded Sheet Typical Size Approx 50 Dash 100 Mm Tech Specification Neat Folded Corners And Concealed Fixing , Surface Treatment - Material Primer Plus Exterior Paint Hdg Typical Size As Specified Tech Specification Anti Corrosion Protection For Outdor Use , Cable Management - Material Outdoor Conduit Typical Size As Required Tech Specification Concealed Vertical Cable Routing Through Pole , Electrical Protection - Material Mcb Spd Earthing Typical Size As Required Tech Specification Waterproof Instalation And Proper Earthing , Febrication And Welding - Material Ms Gi Fabrication Typical Size As Per Structural Detail Tech Specification Continuous Appropriate Welds Visible Welds Ground Smooth , Excavation , Pcc - 100 Mm Thick Below Rcc Footing. , Rcc Footing - M20 Grade Previous Reference Approx 600 X 600 X 750 Mm Final Size To Be Recalculated For Actual Pole Display And Wind Moment , Main Reinforcement - 12 Mm Dia Tmt Bar Number Spacing And Cage Arrangement As Per Structural Design , Distribution Ties , Concrete Cover , Rcc Pedestal - Approx 300 X 300 Mm Raised Above Finished Ground As Required , Anchor Bolts - M16 M20 Gi Or Hdg Quantity Diameter Grade And Bolt Pattern As Per Base Plate Calculation , Anchor Template - Ms Template Plate Keep Bolt Centers Accurate During Rcc Casting , Curing - Proper Curing After Casting Not Load Erect Before Adequate Concrete Strength Is Achieved , Main Pole - 100 X100 X 4 Mm Ms Gi Square Tube Single Pole Support Final Section By Engineer , Pole Height - Approx 12 Ft Above Ground Final Height According To Visibility And Structural Design , Base Plate - 10 Dash12 Mm Ms Plate Typical 250 X 250 Or 300 X 300 Mm Final Plate By Calculation , Gusset Plates - Ms Plate Typically 6 Dash 10 Mm Provided At Polebase Connection As Required , Display Frame - 40X40x2 Mm Or 50X25x2 Mm Ms Gi Rigid Perimeter Intermediate Members Spacing To Match Cabinet Module Fixing Points , Rear Support Grid - Ms Gi Square Rectangular Tube Size Grade According To Connection Design Provide Locking Arrangement Where Required , Fasteners - High Strength Gi Hdg Bolts Nuts & Washers Locking Arrangement Where Required , Welding - Qualified Ms Gi Fabrication Proper Structural Welds Exposed Visible Welds To Be Ground Smooth , Led Module - Common Outdoor Module Format 320 X 160 Mm Fix Into Manufacturer Approved Cabinet Module Receiving Surface , Led Cabinet - Common Modular Cabinet Formats Approx. 960 X 960 Mm Or 960 X 640 Mm Use Exact Cabinet Size Supplied With Selected Led System , Cabinet Fixing - Ms Gi Rear Frame Suitable Brackets Fasteners Align Cabinet Rows Columns Level Faces And Maintain Uniform Joints , Module Alignment - Row By Row Column Bycolumn Correct Orientation And Pixelpitch Continuity , Receiving Card - Inside Cabinet Signal Orientation According To Selected Receiving Card Manufacturer Arrangement , Smps - Inside Cabinet Protected Rear Compartment Quantity And Wattage Based On Actual Led Load , Service Access - Rear Or Front Service Maintain Safe Clearance For Module Smps And Receiving Card Maintenance , Ventilation - Natural Forced Ventilation As Cabinet Design Requires Avoid Blocked Heat Dissipation , Ac Distribution - Dedicated Protected Supply Mcb Isolator Sized From Calculated Load , Smps Input - Properly Rated Outdoor Cable To Each Cabinet Section , Dc Distribution - Manufacturer-Approved Dc Wires Connectors Correct Polarity And Cable Size , Signal Chain - Controller Sending System Receiving Cards Module Data Chain , Power And Signal Separation - Route Power And Signal Wiring Neatly Avoid Unnecessary Parallel Runs , Cable Protection - Uv/Weather Resistant Conduit Flexible Conduit Or Suitable Cable Protection , Cable Entry - Weatherproof Glands Sealed Entries And Drip Loops , Earthing - Bond Metal Structure And Electrical Equipment As Required By Electrical Design , Spd - Surge Protection Recommended Selected According To Electrical Design , Testing - Continuity Polarity Insulation Earthing Signal Sequence And Full Display Load Test , Acp Sheet - 3 Mm Exterior Grade Acp Approved Colour Texture , Pole Cladding - 3 Mm Acp Folded Panels Neat Folded Returns Concealed Mechanically Secure Fixing , Display Border - Approx 50 100 Mm Visible Border Uniform Width Around Display , Side Return Depth , Corners - Folded Bent Where Practical Clean Aligned Corners , Joints - Exteriorgrade Neutralcure Silicone Approved Sealant Weather Sealed Neat Finish , Bottom Closure - Acp Closure Skirting As Required Keep Drainageservice Access Where Needed , Ms Steel - Clean Degrease Suitable Anti Corrosion Primer Exterior-Grade Top Coat , Exposed Outdoor Steel - Prefer Hot Dip Galvanizing Where Specified Otherwise Suitable Epoxy Pu Paint System , Welded Areas - Clean Slag Spatter Grind Where Appropriate And Prime Repaired Areas Before Top Coat , Final Colour - As Per Approved Branding Design Ensure Coating Finish Is Compatible With Primer
|