Part 1 Delivery Of Mobile Energy Storage:1. The Subject Of The Order Is The Supply Of Mobile Energy Storage Units With Additional Equipment - 2 Pieces.2. Technical Specification Of The Energy Storage Unitthe Mobile Energy Storage Unit Is To Have The Following Parameters And Equipment: - Usable Capacity: Min. 55 Kwh, Cells: - Type Lithium-Ion, The Warehouse Should Be Able To Monitor The Battery, Battery Temperature, Battery Charge Status, Voltage Of All Cells, Indicate The Difference Between The Lowest And The Highest Cell, System Monitoring: Display With Current Parameters, Internal Temperature Monitoring, Remote Viewing Of Operating Parameters, Information About The Correct Connection Of The Charging Cable From The Network And The Voltage Of All Phases, The Energy Storage Should Be Able To Be Charged Simultaneously While In Use (Under Load), Nominal Voltage: 400 V - Sockets Min. 3X1f 230 V, 1X3f 16A, 1X3f 32A, Dc+, Dc-The Energy Storage Should Be Mounted On A Trailer With A Maximum Permissible Total Weight Of Up To 1,750 Kg. The Trailer With The Energy Storage Must Be Able To Be Transported By A Passenger Vehicle - Category B, Equipped With A Towbar. Mobile Energy Storages Must Be Able To Be Integrated So That The Power And Capacity Can Be Increased. Possibility Of Charging By A Generator: Model Fh 9000 R, Manufacturer Fogo, (Included In The Ordering Partys Equipment). The Ordering Party Envisages The Configuration Of Two Pairs Of Devices. Additional Equipment: Hybrid Inverter, Car Charger Eva) Specification Of The Hybrid Inverter - Power Min. 19 Kw Pv Input: - Maximum Input Voltage - Min. 1000V- Starting Voltage - 180V- Mppt Voltage Range - Min. 160V-960V- Rated Voltage - 400V- Maximum Input Current - Min. 25A Output When Off The Grid: - Rated Output Voltage - 230V/400V (+-10%) - Rated Output Current - Min. 3*29A- - Output Frequency - 50Hz Output On The Network: - Rated Output Power - Min. 19 Kw - Rated Output Voltage - 230/400V; - Output Frequency - 50Hz Required Protection: - Inputs Against Reverse, Output Overcurrent, Output Overvoltage, Against Islanding, Rcmu, Insulation Resistance Monitoring, - Overvoltage Protection - Iii, - Protection Level - Ip65 Compliance With Standards: Emc - En 61000-6-2, En 61000-6-3, En 61000-3-2, En 61000-3-3, En 61000-3-11,En 61000-3-12, Safety Standards - Iec62109-1/2, Iec62040-1, Iec62116, Iec61727,Iec-61683, Iec60068(1,2,14,30), Network Standards - As/Nzs 4777, Vde V 0124-100, V 0126-1-1, Vde-Ar-N 4105, Cei0-21, En50438/En50549, G83/G59/G98/G99, Ute C15-712-1, Une 206 007-1B) Ev Charger Specifications:- Ac Charger 22 Kw, Type 2, Connector: 3-Phase With Protective Conductor, Ac Charging, - Possibility Of Operation Outside The Energy Storage - Compliance With The Standards: Iec 61851-1, Iec 61851-21-2, Ce Emc Eu/2014/30, Ce Emc Eu/2014/35, Red Eu/2014 Detailed Description Of The Subject Of The Order, Description Of The Ordering Partys Requirements Regarding Implementation And Acceptance For Part 1 Specifies: -
|