Battery Mccbs For UPS Systems At UCB And BOP Plcs , Model: Tmax T1B 160 Rated Current (In): 100 A Rated Uninterrupted Current (Iu):160 A,Breaking Capacity Is Equal To 16KA At 415V,Thermo Magnetic Release Type Rated Impulse Withstand Voltage (Uimp): 8 KV Rated Insulation Voltage (Ui): 800 V Rated Operational Voltage Ue Is Equal To 690V AC, Also Provision For Under Voltage Trip Coil With Coil Voltage Rating Is Equal To 110V DC Auxillary Contacts For ON/OFF Status Feedback To UPS Makes: ABB/L And T/Schnider Make 3 Pole MCCB Equivallent To ABB SACE Tmax MCCB , 3 Pole MCCB At Equivalant To L And T Make DH250 : MCCB 250 Amps Rated Operating Voltage Ue Is Equal To 415Volts At 50Hz,Insulation Voltage Ui Is Equal To 690V At 50HZ, Short Ckt Breaking Capacity I Cu Is Equal To 35Ka , Service Breaking Capacity Ics Is Equal To 100% I Cu, Utilization Category- A With Thermal Magnetic Release, Actual Trip Setting In Is Equal To 250A, Instantaneous Is Equal To 6 In , Also Provision For Under Voltage Trip Coil With Coil Voltage Is Equal To 110V DC And Auxillary Contacts For ON/OFF Status Feedback To UPS Makes: ABB/L And T/Schnider , 3Pole MCCB ,Rated Current: 63Amps(In),Breaking Capacity: 10 Ka At 415Volt, Insulation Voltage: 690Volts, Uimp(Impulse With Stand Voltage): 8KV Makes:ABB/L And T/Schnider , 3 Pole MCCB Equivalent To L And T Make DH400 At 400Amps Rated Operating Voltage Ue Is Equal To 415Volts At 50Hz,Insulation Voltage Ui Is Equal To 690V At 50HZ, Short Ckt Breaking Capacity I Cu Is Equal To 35Ka , Service Breaking Capacity Ics Is Equal To 100% I Cu, Utilization Category- A With Thermal Magnetic Release, Actual Trip Setting In Is Equal To 400A, Instantaneous Is Equal To 6 In Makes: ABB/L And T/Schnider , 3 Pole MCCB Equivallent To Merlin Gerin Model: NKS100R, Type:MCCB,3Pole Rated Current (In): 100 A Breaking Capacity Is Equal To 10KA At 415V, Service Breaking Capacity(Ics):50% Of Icu Is Equal To 5KA. Rated Impulse Withstand Voltage (Uimp): 8 KV Rated Insulation Voltage (Ui): 690 V Rated Operational Voltage Ue Is Equal To 415V AC, Frequency:50/60Hz,Standard :Cat A,IEC 60947-2/IS 13947(Part 2) Makes: ABB/L And T/Schnider /Merlin Gerin , 3 Pole MCCB Equivallent To Merlin Gerin Model: NKS100R, Type:MCCB,3Pole Rated Current (In): 50 A Breaking Capacity Is Equal To 10KA At 415V, Service Breaking Capacity(Ics):50% Of Icu Is Equal To 5KA. Rated Impulse Withstand Voltage (Uimp): 8 KV Rated Insulation Voltage (Ui): 690 V Rated Operational Voltage Ue Is Equal To 415V AC, Frequency:50/60Hz,Standard :Cat A,IEC 60947-2/IS 13947(Part 2) Makes: ABB/L And T/Schnider /Merlin Gerin , 3 Phase Un-Balance RMS Monitoring Relay, L1,2,3: 3- 300-500V 50Hz, 0,1 S - 30S/ 2 C/O Ithe Is Equal To 4A, U Imp Is Equal To 6KV/4Kv Fuse(Fast):10A NO, 6A(NC)/1Ka, AC15:230V 3A DC13: 24V/2A Model Equivallant To ABB Make CM-PAS.41S/ 1SVR730774R3300( Order Code For ABB Make)
|